The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17 published a Special Notice announcing their intent to award a single-source contract to Elekta, Inc. The notice regards maintenance and repair services for a Versa HD radiotherapy system and thirteen associated components located at the VA Aurora Cancer Center in San Antonio, Texas.

The Special Notice provides details of the agency's plan to solicit and award a firm-fixed price, single-source service maintenance agreement to Elekta, Inc. for one base year with four option years of full maintenance coverage for the listed radiotherapy equipment. Interested firms must respond by 12:00pm CDT on April 14, 2021 to be considered for the award, however the notice states no contract will be awarded based on responses and the government retains discretion to make the sole source award. Elekta, Inc. would provide proprietary software upgrades, parts, and coverage for specific component replacements to minimize downtime and maintain equipment in compliance with regulatory standards.

Notice text

Special Notice Notice of Intent to Award a Single-Source Procurement

The Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network (VISN) 17, Network Contracting Office (NCO) 17, located at 5441 Babcock Road, Ste. 302, San Antonio, TX 78240 intends to solicit and award a single-source firm-fixed priced service maintenance agreement for one (1) base year and four (4) option years to Elekta, Inc. for the following equipment:

VA EE IDENTIFICATION: 139062

SITE IDENTIFICATION NUMBER: 154178

MANUFACTURER: Elekta Inc.

EQUIPMENT DESCRIPTION: Radiotherapy System

MODEL #: Versa HD

SERIAL #: 154178

LOCATION: VA Aurora Cancer Center; Oncology Department; 9102 Floyd Curl Drive, San Antonio, Texas 78240.

COVERAGE: FULL MAINTENANCE SERVICE AGREEMENT

The listed equipment systems below are subcomponents of main system and are to be included:

Active Breathing Coordinator, serial number 000365, SO002-Y

Electron Energies, SO014-Y

Fraxion, SO071-Y

HDRM, SO096-Y

HexaPOD evo RT Module System, serial number 04552, SO021-Y

Photon Energies, SO003-Y

Response, SO098-Y

Agility, serial number 291329, SO089-Y

Precisebeam VMAT, SO067-Y

XVI System, serial number 336268, SO069-Y

iViewGT System, serial number 301740, SO025-Y

Treatment Suite Control System, serial number 311337

NPSS (Precise Treatment Table), serial number 228074

Title 21 (CFR 21), Joint Commission Accreditation Healthcare Organization (JCAHO) and Original Equipment Manufacturers (OEM) standards is mandatory.

Parts:

The Contractor shall furnish all proprietary software, upgrades and parts as necessary to maintain the equipment, covered by this contract, in accordance with the Conformance Standards Section. The Contractor stipulates by submitting his offer that he has ready access to new proprietary software, upgrades and parts (manufactured, supplied by the manufacturer). All proprietary licensed software upgrades and parts supplied shall be of current manufacture and have full compatibility with existing equipment. Documentation of intended parts source(s) shall be provided to the Contracting Officer upon request. All parts necessary for the maintenance or repair of this equipment shall be furnished as part of this contract. Refurbished parts will not be acceptable. Parts are to be delivered with a 95 percent same day shipment of all stock parts to minimize down time of covered systems. The following spare parts coverage must be included:

Thyratron replacement coverage OO_USPC_THY

Agility camera coverage OO_USPC_MLCC_AG

Electron Gun replacement coverage OO_USPC_ELG

IViewGT Panel replacement coverage OO_USPC_IVGTPNL

XVI Panel replacement coverage OO_USPC_XVIPNL

Xray tube replacement coverage OO_USPC_XRAYTB

Ion Chamber replacement coverage OO_USPC_IONCMB

Magnetron replacement coverage OO_USPC_MAGSTD

Documentation/Reports:

The Contractor shall submit a legible field service report within 3 working days, which shall include detailed descriptions of the preventive maintenance inspection and/or emergency repair services performed, including replaced parts and estimated prices required for the service call.

Competency of Personnel Servicing Equipment:

The Contractor s staff shall include a fully qualified Field Service Representative assigned to this area and a fully qualified Field Service Representative who shall serve as the backup.

Fully qualified is based upon training and on experience in the field. For training, the Field Service Representatives must have successfully completed a formalized training program for the equipment covered under this contract. For field experience, the Field Service Engineers must have a minimum of one (1) year of experience providing preventive maintenance and emergency repair services on the same make and model of equipment covered under this contract.

The NAICS Code for this procurement is 811219 Other Electronic and Precision Equipment Repair and Maintenance with a Small Business Size Standard of $22 Million. This action is accomplished under FAR 13.106-1(b)(1)(i), Soliciting from a Single-Source . This notice is not to be considered a request for quotations or proposals. No contract will be awarded based on offers received in response to this notice; however, any offers received may be used to determine if a comparable source is available and more advantageous to the government. All responsible sources may submit a response; which, if timely received, will be considered by the agency. If parties choose to respond, any cost associated with preparation and submission of data or cost incurred in response to this announcement shall be the sole responsibility of the contractor and will not be reimbursed by the Government. A determination by the Government not to compete this proposed procurement based upon responses to this notice is solely within the discretion of the Government. If no affirmative written response is received by the response date and time, a purchase order will be issued to Elekta, Inc. without any further notice. Interested firms must respond directly to Joseph.Leyte@va.gov no later than 12:00 P.M. CDT on April 14, 2021.

Files

File Type Posted
36C25721Q0636.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
J065--FY27 (BASE 4) RaySearch America RayStation Treatment Planning System Service Contract NAICS 541519 Veterans Integrated Service Network 2 No set-aside
J065--Siemens Luminos Agile Max XR3 Repair Department of Veterans Affairs Palo Alto VA Health Care System (Pavahcs) Palo Alto CA 94304, United States · NAICS 811210 Veterans Integrated Service Network 21 No set-aside
FRESNO- Radiology X-Ray System PM Services NAICS 811210 Veterans Integrated Service Network 21 No set-aside
DA10--Nurse Call Software Maintenance - NWI Department of Veteran Affairs Omaha VA Medical Center Omaha, Nebraska 68015, United States · NAICS 541512 Veterans Integrated Service Network 23 No set-aside
J065--Philips Imaging Equipment preventative maintenance and repair services at the Northport VA Medical Center NAICS 811210 Veterans Integrated Service Network 2 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity