Bldg 1000 Lab Server Rooms Cooling Units

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
N6449821R4037
Agency
Naval Sea Systems Command Department of the Navy, Department of Defense
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
Y1PZ Construction Of Other Non-Building Facilities
Place of performance
Philadelphia, Pennsylvania 19112, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Naval Surface Warfare Center, Philadelphia Division is soliciting proposals to remove three existing temporary cooling units and install new Computer Room Air Conditioning units in several server rooms at Building 1000. Specifically, the contractor will install three 5-ton CRAC units in room 477A, one 8-ton unit in room 473A, and one 10-ton unit in room 473 ducted to room 473A. The work must be performed by an authorized Automated Logic installer. The solicitation will evaluate offerors based on technical qualifications, past performance, and price. Proposals are due by September 23, 2021.

This requirement has been set aside for total small business. The primary NAICS code is 238210 and PSC code R499. The period of performance is estimated at 120 days with a place of performance in Philadelphia, Pennsylvania. Key details include installing five CRAC units totaling 23 tons of cooling capacity. The temporary portable air conditioning units currently in the server rooms must be returned to the Government.

Notice text

The Naval Surface Warfare Center, Philadelphia Division intends to initiate a Request for Proposal (RFP) to remove the existing the temporary cooling units and install three (3) 5-ton Computer Room Air Conditioning (CRAC) units in room 477A, one (1) 8-ton CRAC unit in room 473A, and one (1) 10-ton CRAC unit in room 473 that will be ducted into room 473A.  The Contractor shall return the temporary portable A/C units to the Government for future use. The Contractor must use an authorized Automated Logic installer. After completion of all work, the area shall be properly cleaned and the system shall be balanced and tested. Work shall be performed during normal duty hours from 0700 to 1600, Monday through Friday.

Period of performance including delivery is estimated at 120 Days after receipt of Notice to Proceed.

Attachments

Show all 16

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Bldg 1000 Lab Server Rooms Cooling Units Award Award Notice
Bldg 1000 Lab Server Rooms Cooling Units This notice · Latest solicitation Solicitation
Bldg 1000 Lab Server Rooms Cooling Units Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity