Chapter 11
Telecommunications Systems
Chapter 11. Telecommunications Systems
A. Applicability
1. This guidance is compatible with, but may not satisfy, security requirements of other disciplines such as Information Systems Security, Communications Security (COMSEC), Operational Security (OPSEC), or TEMPEST.
2. This section outlines the security requirements that shall be met to ensure the following:
Protection of information.
Configuration of unclassified telecommunications systems, devices, features, and software.
Access control.
Control of the cable infrastructure.
B. Unclassified Telephone Systems
1. A baseline configuration of all unclassified telephone systems, devices, features, and software shall be established, documented, and included in the SCIF FFC.
2. The AO shall review the telephone system baseline configuration and supporting information to determine if the risk of information loss or exploitation has been suitably mitigated.
3. When security requirements cannot be met, unclassified telephone equipment shall be installed and maintained in non-discussion areas only.
4. When not in use, unclassified telephone systems shall not transmit audio and shall be configured to prevent external control or activation, technical exploitation, or penetration.
5. Unclassified telephone systems shall incorporate physical and software access controls to prevent disclosure or manipulation of system programming and data. The following specific requirements shall be met:
a) On-hook and off-hook audio protection shall be provided by equipment identified by the National Telephone Security Working Group within TSG-6/CNSSI 5006, National Instruction for Approved Telephone Equipment, or an equivalent TSG 2/
CNSSI 5002:
(1) The purpose of a TSG-2 or CNSS 5002 Computerized Telephone Switch
(CTS) installation is to prevent manipulation of telephone instruments to obtain audio from within the SCIF while the instrument is in an "on-hook" condition.
(2) When isolation is provided by a CTS installed IAW TSG-2 or CNSS 5002, the
AO accepts the risk on-hook audio from the SCIF may be present on all instrument wiring until it reaches the CTS due to instrument configuration, design, or breakdown. (TSG-2/CNSS 5002 does not address procedures to determine security of the station itself.)
(3) To provide the necessary level of security, the Physically Protected Space
(PPS) where the CTS is installed must meet equivalent security and access control standards as the SCIF it supports to provide positive physical protection for the
CTS and all of its parts. (CNSSI 5002 para 7.A.(1) ). This includes all instruments, cables, lines, intermediate wiring frames, and distributed CTS modules necessary for the functioning of the instruments.
(4) The AO may require all instrument wiring exiting between the SCIF and PPS which is not at the SCIF level be contained in a closed and sealed metal conveyance as defined in Chapter 7.A.2 to ensure physical security of the instrument wiring.
(5) Telephones or instruments not type-accepted will be presumed to have on-hook audio available at the mounting cord until determined otherwise.
Determining telephone stations do not have on-hook audio hazards requires a technical investigation and specific equipment. These investigations and determinations may only be conducted by a TSCM team or National Telephone
Security Working Group (NTSWG) authorized telephone laboratory.
b) If a Computerized Telephone System (CTS) is selected for isolation, it shall be installed and configured as detailed in TSG 2 with software and hardware configuration control and audit reporting (such as station message detail reporting, call detail reporting, etc.).
c) System programming shall not include the ability to place, or keep, a handset off-hook.
d) Configuration of the system shall ensure that all on-hook and off-hook vulnerabilities are mitigated.
e) When local or remote CTS administration terminals are not contained within a controlled area and safeguarded against unauthorized manipulation, the use of CNSSI
5006 approved telephone instruments shall be required, regardless of the CTS configuration.
f) Speakerphones and audio conferencing systems shall not be used on unclassified telephone systems in SCIFs. Exceptions to this requirement may be approved by the
AO when these systems have sufficient audio isolation from other classified discussion areas in the SCIF and procedures are established to prevent inadvertent transmission outside the SCIF.
g) Features used for voice mail or unified messaging services shall be configured to prevent access to remote diagnostic ports, internal dial tone, and dial plans.
h) Telephone answering devices and facsimile machines shall not contain features that introduce security vulnerabilities, e.g., remote room monitoring, remote programming, or other similar features that may permit off-premise access to room audio.
i) All unclassified telephone systems and associated infrastructure shall be physically isolated from classified information and telecommunications systems in accordance with DNI and CNSS TEMPEST guidance.
j) TSG6/CNSSI 5006 approved instruments or compliance with CNSSI 5000 is required for installation in SCIFs for Voice over Internet Protocol (VoIP) systems installed in a SCIF. TSG6/CNSSI 5006 approved instruments must be installed following the manufacturer’s requirements. For non-TSG6/CNSSI 5006 approved instruments, the security requirements and installation guidelines contained in the
National Telecommunications Security Working Group (NTSWG) publication
CNSSI 5000 shall be followed for Voice over Internet Protocol (VoIP) systems installed in a SCIF.
C. Unclassified Information Systems
1. Unclassified information systems shall be safeguarded to prevent hardware or software manipulation that could result in the compromise of data.
2. Information systems equipment with telephonic or audio features shall be protected against remote activation and/or removal of audio (analog or digitized) information.
3. Video cameras used for unclassified video teleconferencing and video recording equipment shall be deactivated and disconnected when not in use.
4. Video devices shall feature a clearly visible indicator to alert SCIF personnel when recording or transmitting.
D. Using Closed Circuit Television (CCTV) to Monitor the SCIF Entry
Point(s)
1. CCTV may be used to supplement the monitoring of a SCIF entrance and to record events for investigation.
2. The system shall present no technical security hazard to the SCIF.
3. The system and all components, including communications and control lines, shall be exterior to the SCIF perimeter.
4. The system may provide a clear view of the SCIF entrance but not enable the viewer to observe classified information when the door is open nor external control pads or access control components that would enable them to identify PINs.
E. Unclassified Wireless Network Technology
1. The use of devices or systems utilizing wireless technologies pose a high risk and require approval from the AO, CTTA, and IT systems approving authority prior to introduction into the SCIF.
2. Wireless systems shall meet all TEMPEST and TSCM requirements and shall be weighed against the facilities overall security posture (i.e., facility location, threat, as well as any compensatory countermeasures that create SID) when evaluating these systems.
3. All separation and isolation standards provided in TEMPEST standards are applicable to unclassified wireless systems installed or used in SCIFs.
F. Environmental Infrastructure Systems
1. The FFC shall include information on whether or not environmental infrastructure systems (also referred to as building maintenance systems) are located in the SCIF.
Examples include the following:
Premise management systems
Environmental control systems
Lighting and power control units
Uninterrupted power sources
2. The FFC shall identify all external connections for infrastructure systems that service the SCIF. Examples of the purpose of external connections include the following:
Remote monitoring
Access and external control of features and services
Protection measures taken to prevent malicious activity, intrusion, and exploitation.
G. Emergency Notification Systems
1. The introduction of electronic systems that have components outside the SCIF perimeter is prohibited, with the following exceptions:
a) The system is approved by the AO.
b) The system is required for security purposes.
c) The system is required under life safety regulations.
2. If required, and speakers or other transducers are part of a system that is not wholly contained in the SCIF but are installed in the SCIF for life safety or fire regulations, the system must be protected as follows:
a) All incoming wiring shall breach the SCIF perimeter at one point. TEMPEST or
TSCM concerns may require electronic isolation and shall require review and approval by the CTTA.
b) One-way (audio into the SCIF) communication systems shall have a high gain amplifier.
c) Two-way communication systems shall only be approved when absolutely necessary to meet safety/security requirements. They shall be protected so that audio cannot leave the SCIF without the SCIF occupants being alerted when the system is activated.
d) All electronic isolation components shall be installed within the SCIF and as close to the point of SCIF penetration as possible.
H. Systems Access
1. Installation and maintenance of unclassified systems and devices supporting SCIF operations may require physical or remote access. The requirements outlined in this section shall apply to telecommunications devices located within the SCIF or in a controlled area outside the SCIF.
2. Installation and maintenance personnel requiring physical access shall possess the appropriate clearance and access, or will be escorted and monitored at all times within the
SCIF by technically knowledgeable, U.S. SCI-indoctrinated personnel.
3. Remote maintenance shall be protected against manipulation or activation.
4. All capabilities for remote maintenance and diagnostic services shall be specified in the FFC.
5. The FFC shall identify all procedures and countermeasures to prevent unauthorized system access, unauthorized system modification, or introduction of unauthorized software.
6. Remote maintenance and diagnosis may be performed from a SCIF or an adjacent controlled area over a protected link in accordance with FIPS AES standards.
7. Telephone systems only may be accessed over an unclassified telephone line as specified in TSG 2 Standard, Section 4.c.
I. Unclassified Cable Control
1. To the extent possible, all telecommunications cabling shall enter the SCIF through a single opening and allow for visual inspection.
2. Cable, either fiber or metallic, shall be accounted for from the point of entry into the
SCIF.
a) The accountability shall identify the precise use of every cable through labeling.
b) Log entries may also be used.
c) Designated spare conductors shall be identified, labeled, and bundled together.
3. Unused conductors shall be removed. If removal is not feasible, the metallic conductors shall be stripped, bound together, and grounded at the point of ingress/egress.
4. Unused fiber shall be uncoupled from the interface within the SCIF, capped, and labeled as unused fiber.
J. Protected Distribution Systems
1. Unencrypted communication cables transmitting SCI between accredited SCIFs shall be installed in a Protective Distribution System that complies with standards established in CNSSI 7003, Protected Distribution System.
2. PDS used to protect SCI shall be approved by the CSA AO.
K. References
1. Overview
a) The NTSWG publishes guidance for the protection of sensitive information and unclassified telecommunications information processing systems and equipment.
b) NTSWG documents are currently in transition from TSG/NTSWG documents to
Committee on National Security Systems (CNSS) publications.
c) The List of References is provided for use by personnel concerned with telecommunications security.
2. List of References
a) TSG Standard 1 (Introduction to Telephone Security). Provides telephone security background and approved options for telephone installations in USG sensitive discussion areas.
b) TSG Standard 2 (TSG Guidelines for Computerized Telephone Systems) and
Annexes. Establishes requirements for planning, installing, maintaining, and managing CTS, and provides guidance for personnel involved in writing contracts, inspecting, and providing system administration of CTS.
c) TSG Standards 3, 4, 5, and CNSSI 5001. Contains design specifications for telecommunication manufacturers and are not necessarily applicable to facility security personnel.
d) CNSSI 5000. Establishes requirements for planning, installing, maintaining, and managing VoIP systems.
e) CNSSI 5006. Lists approved equipment which inherently provide on-hook security.
f) NTSWG Information Series (Computerized Telephone Systems). A Review of
Deficiencies, Threats, and Risks, December 1994). Describes deficiencies, threats, and risks associated with using computerized telephone systems.
g) NTSWG Information Series (Executive Overview, October 1996). Provides the salient points of the TSG standards and presents them in a non-technical format.
h) NTSWG Information Series (Central Office (CO) Interfaces, November 1997).
Provides an understanding of the types of services delivered by the local central office and describes how they are connected to administrative telecommunications systems and devices.
i) NTSWG/NRO Information Series (Everything You Always Wanted to Know about Telephone Security…but were afraid to ask, 2nd Edition, December 1998).
Distills the essence of the TSG standards (which contain sound telecommunications practices) and presents them in a readable, non-technical manner.
j) NTSWG/NRO Information Series (Infrastructure Surety Program…securing the last mile, April 1999). Provides an understanding of office automation and infrastructure system protection that contributes to SCIF operation.
k) NTSWG Information Series (Computerized Telephone Systems Security Plan
Manual, May 1999). Assists to implement and maintain the “secure” operation of
CTSs as used to support SCIF operations. (The term “secure” relates to the safe and risk-free operation, not the use of encryption or a transmission security device.)
l) Director of National Intelligence, Intelligence Community Directive 702, Technical Surveillance Countermeasures.
m) Director of National Intelligence, Intelligence Community Directive 503, Intelligence Community Information Technology Systems Security Risk
Management, Certification and Accreditation.
n) SPB Issuance 00-2 (18 January 2000). Infrastructure Surety Program and the
Management Assessment Tool.
This page intentionally left blank.
Chapter 12
Management and Operations
Chapter 12. Management and Operations
A. Purpose
To establish safeguards and procedures necessary to prevent the unauthorized disclosure of SCI and other classified national security information in SCIFs. To define administrative processes that shall provide a secure operating environment and enable adequate security oversight, management, and operations of SCIFs.
B. SCIF Repository
1. As required by ICD 705, the DNI shall manage an inventory of information on all
SCIFs which shall be reported to the DNI via the SCIF repository not later than 180 days after the effective date of ICD 705 and updated no later than 30 days after changes occur thereafter.
2. Reportable SCIF Administrative Information:
SCIF ID
AO ID
Location of SCIF o In U.S.
o Outside U.S.
o Under COM
SCIF Type o Closed Storage o Open Storage o SWA o TSWA o T-SCIF
SID
Initial Accredited Date
Re-Accreditation Date
Review date
Waivers
Date waiver approved
Waiver approval authority/ID
Exceeded standards
Does not meet standards
Date waiver expires
C. SCIF Management
1. SO Responsibilities:
a) The SCIF SO shall be responsible for all aspects of SCIF management and operations to include security policy implementation and oversight.
b) The SO shall prepare a comprehensive Standard Operating Procedure (SOP) that documents management and operations of the SCIF.
c) The SO shall review the SOP at least annually and revise it when any aspect of
SCIF security changes.
d) The SO shall issue and control all SCIF keys. Locks shall be changed when a key is lost or is believed to be compromised.
e) The SO shall conduct annual self-inspections to ensure the continued security of
SCIF operations, identify deficiencies, and document corrective actions taken.
Inspection results shall be forwarded to the AO and copies retained by the SO until the next inspection.
f) The SO shall create an emergency plan to be approved by the AO. Plans shall be reviewed and updated annually and all SCIF occupants shall be familiar with the plans. Drills shall be conducted as circumstances warrant, but at least annually. The emergency plan may be an extension of an overall department, agency, or installation plan.
(1) For SCIFs within the U.S., emergency plans shall address the following:
Fire
Natural disaster
Civil unrest
Intrusion detection system failures
Admittance of emergency personnel
The protection of SCIF occupants and classified information
Evacuation requirements and emergency destruction
(2) For SCIFs outside the U.S., emergency plans shall address all of the above and shall include instructions for the emergency destruction or removal of SCI where political instability, terrorism, host country attitudes, or criminal activity suggest the possibility that a SCIF may be overrun.
g) The SO shall control passwords to access the maintenance mode of copiers and other office equipment.
h) The SO shall develop an SOP that addresses actions to be taken when IDS maintenance access is required.
2. Required SCIF Documentation
a) Copies of all documents relating to SCIF accreditation shall be maintained by the
SCIF SO and include, but not limited to, the following:
SCIF accreditation
Fixed facility checklist
Construction security plan
CTTA evaluation
IS accreditation
SOPs
The results of the final acceptance test of the original system installation and any tests to system modifications made thereafter
Emergency plan
b) As applicable, the following documents shall be maintained by the SCIF SO:
TSCM reports
Co-utilization agreements
Memoranda of agreement
Self-inspection reports
Compartmented area checklist
Shipboard SCIF checklist
Aircraft/UAV checklist
A copy of the CRZH certificate (UL 2050)
D. SOPs
1. A comprehensive SOP that documents management and operations of the SCIF shall be prepared by the SO.
2. The SOP shall be included in the accreditation package and approved by the AO.
3. All individuals assigned to, or having unescorted access to, the SCIF shall be familiar with and adhere to the SOP.
4. All SOP revisions shall be provided to the AO for approval.
5. SOPs shall be tailored to a specific SCIF.
6. SOPs shall include specific areas of security concern as defined by program or mission requirements.
7. The following are examples of subjects that should be addressed in an SOP:
Self-inspections
Security incidents and violations
Alarm systems and response requirements
Opening and closing procedures
Access controls
Visitor access
Escort procedures
Equipment maintenance procedures
Handling, processing, and destruction of classified material
Badge procedures
End-of-day security procedures
Personnel and package inspection procedures
Secure communications device instructions
E. Changes in Security and Accreditation
1. Changes affecting the security posture of the SCIF shall be immediately reported by the SO to the AO to include any corrective or mitigating actions taken.
2. If an AO determines that SCIF security conditions are unsatisfactory, SCIF accreditation may be suspended or revoked.
a) All appropriate authorities and SCIF occupants shall be immediately notified and the SCIF closed until deficient conditions are corrected.
b) All SCI material shall be relocated to another SCIF.
F. General
1. Except for law enforcement officials or other personnel required to be armed in the performance of their duties, firearms and other weapons are prohibited in SCIFs.
2. Photography, video, and audio recording equipment are restricted but may be authorized for official purposes as documented in the SOP.
3. Procedures shall be established to control IT storage media upon entering or exiting a
SCIF in accordance with ICD 503 (Intelligence Community Information Technology
Systems Security Risk Management, Certification and Accreditation).
4. SCIF perimeter doors shall remain closed and controlled at all times. When a door needs to be open, it shall be continually monitored by an SCI-indoctrinated individual.
5. All SCIF occupants shall be familiar with emergency plans and drills shall be conducted as circumstances warrant, but at least annually.
6. Where the risk of hostile action is significant, SCI materials shall be maintained at an absolute minimum.
G. Inspections/Reviews
1. SCIF inspections shall be performed by the AO, or designee, prior to accreditation.
2. The AO, or designee, shall conduct periodic security inspections/reviews to ensure the efficiency of SCIF operations, identify deficiencies, and document corrective actions taken. All relevant documentation associated with SCIF accreditation, inspections, and security administration may be subject to review.
3. Periodic inspections/reviews shall be conducted based on threat, facility modifications, sensitivity of programs, past security performance, or at least every five years.
4. SOs shall conduct annual self-inspections to ensure the continued security of SCIF operations, identification of deficiencies, and to document corrective actions taken.
Inspection results shall be forwarded to the AO and copies retained by the SO until the next inspection.
5. Authorized inspectors shall be admitted to a SCIF without delay or hindrance when inspection personnel are properly certified to have the appropriate level of security clearance and SCI indoctrination for the security level of the SCIF.
6. Short-notice or emergency conditions may warrant entry without regard to the normal
SCIF duty hours.
7. Government-owned equipment needed to conduct SCIF inspections will be admitted into the SCIF without delay. Specifically, equipment for TEMPEST or Technical
Surveillance Countermeasures (TSCM) testing shall be admitted to a SCIF as long as the personnel operating the equipment are certified to have the appropriate level of security clearance and SCI indoctrination.
H. Control of Combinations
1. Combinations to locks installed on security containers/safes, perimeter doors, windows, and any other opening should be changed in the following circumstances:
a) When a combination lock is first installed or used.
b) When a combination has been subjected, or believed to have been subjected, to compromise.
c) Whenever a person knowing the combination no longer requires access to it unless other sufficient controls exist to prevent access to the lock.
d) At other times when considered necessary by the SO.
2. When the lock is taken out of service, it will be reset to 50-25-50.
3. All combinations to the SCIF entrance doors should be stored in a different SCIF.
When this is not feasible, alternative arrangements shall be made in coordination with the
AO.
I. De-Accreditation Guidelines
SCIF closeouts and de-accreditations shall comply with the following procedures:
1. Inspect all areas, storage containers, and furniture for the presence of classified, sensitive, or proprietary information, and remove any found.
2. Reset safe combinations to 50-25-50 and lock the containers.
3. Affix written certification to all storage containers that the container does not contain classified, sensitive, or proprietary information. The certification shall include the date of inspection and the name and signature of the inspector.
4. Ensure that reproduction and printing equipment is decertified or disposed of in accordance with AO guidance.
5. Dispose of, or relocate, SCI computer equipment, media, hard drives, and portable storage media as approved by the AO.
6. Request revocation of Automated Information Systems (AIS) accreditation.
7. Request revocation of SCIF accreditation.
8. If the SCIF will be used for another mission or project that requires alarms, transfer alarm service to the new activity.
9. If the SCIF will not be used for another mission or project and all classified, sensitive, or proprietary information has been removed, the following shall occur:
a) Alarm service shall be discontinued.
b) Combinations on the entrance door and any GSA containers shall be changed to
50-25-50.
c) All keys shall be accounted for.
J. Visitor Access
1. General Requirements
a) Visitor logs shall be used to record all SCIF visitors and include the following information:
Visitor’s full name
Organization
Citizenship
Purpose of the visit
Point of contact
Date/time of the visit
b) Government-issued identification shall be required as a means of positive identification.
c) Visitor logs shall be retained for two years after the date of the last entry.
d) Visitor clearance verification shall be accomplished using the DNI Scattered
Castles database to the greatest extent possible.
e) Visitors whose clearances have not been verified may be permitted, under escort, entry into the SCIF; however, access to and/or discussion of classified information shall be denied pending clearance verification.
f) Visitors, SCIF occupants, and their possessions may be subject to screening and inspections to deter the unauthorized removal of classified material or the introduction of prohibited items or contraband.
g) Screening and inspection procedures shall be documented and approved by the
AO.
2. SCIF Access by Uncleared and Emergency Personnel
a) Uncleared personnel shall be escorted at all times by cleared personnel.
b) The ratio of cleared escorts to uncleared personnel shall be determined on a case-by-case basis by the SO.
c) Prior to assuming escort duties, all escorts shall receive a briefing by the SO or designee outlining their responsibilities.
d) Uncleared personnel shall be kept under observation at all times while in the
SCIF. Escorts shall ensure precautions are taken to preclude inadvertent access to classified information.
e) Lights, signs, or other alerting mechanisms or procedures shall be used to alert
SCIF occupants of the presence of uncleared personnel.
f) Emergency personnel and equipment shall be allowed access to SCIFs and be escorted to the degree practical. If exposed to classified information, they shall sign an inadvertent disclosure statement when feasible.
K. Maintenance
1. SCI-indoctrinated maintenance personnel shall be used to the extent possible.
2. Procedures for performing maintenance on office equipment, including the use of diagnostic equipment, shall be documented in the SCIF SOP.
3. Computerized diagnostic equipment, to include associated hardware and software, shall be kept under control within a SCIF and shall be managed to prohibit the migration of classified data when connected to classified systems. Procedures shall be documented in the SOP.
4. Passwords to access the maintenance mode of copiers and other office equipment shall be controlled by the SO.
5. Office equipment that is no longer serviceable, such as copiers and classified fax machines, shall be sanitized by having volatile memory erased and non-volatile memory and disk storage removed for terminal destruction.
L. IDS and ACS Documentation Requirements
The following documents and records shall be maintained by the SCIF SO:
1. System Plans such as system design, equipment, and installation documentation.
2. If applicable, agreements established for external monitoring, response, or both, and which shall include the following information:
Response time for response forces and SCI indoctrinated personnel.
Responsibilities of the response force upon arrival.
Maintenance of SCIF points of contact.
Length of time response personnel are required to remain on-site.
3. Monitoring Station SOP and/or a copy of the monitoring station UL certificate.
4. Maintenance access SOP.
5. Records, logs, and archives.
6. Records of system testing (for two years) shall include the following information:
Testing dates
Names of individuals performing the test
Specific equipment tested
Malfunctions detected
Corrective actions taken
7. Records of guard or response force personnel testing as required by the AO.
8. The PCU shall contain a secured, non-volatile event (alarm) log capable of storing at least six months of events, or a printer shall be installed that provides real-time recording of openings, closings, alarms, trouble alarms, and loss of communications.
a) If the system has no provision for automatic entry into archive, the AO may authorize a manual logging system.
b) Monitoring personnel shall record t+he time, source, type of alarm, and action taken.
c) The SCIF SO shall routinely review the historical records.
d) Results of investigations and observations by the response force shall also be maintained at the monitoring station.
e) Records of alarm annunciations shall be retained for two years.
f) Shunting or masking of any zone or sensor shall be logged in the system archives.
g) All maintenance periods shall be archived into the system.
h) An archive shall be maintained for all remote service mode activities.
9. Access Control Systems Records which include:
a) The active assignment of ID badge/card, PIN, level of access, entries, and similar system-related information
b) Records of personnel removed from the system which shall be retained for two years from the date of removal.
10. Records of security incidents (violations/infractions) regarding automated systems shall be retained by the SO for five years from the date of an incident or until investigations of system violations and incidents have been resolved.
M. Emergency Plan
1. The SO shall create an emergency plan.
2. The emergency plan shall be approved by the AO and maintained on-site for each accredited SCIF.
3. The emergency plan may be an extension of an overall department, agency, or installation plan.
4. The emergency plan shall address the following:
Fire
Natural disaster
Civil unrest
Intrusion detection system failures
Admittance of emergency personnel into a SCIF
The protection of SCIF occupants and classified information
Evacuation requirements and emergency destruction
5. Plans shall be reviewed at least annually and updated as necessary.
6. All SCIF occupants shall be familiar with the plans and drills shall be conducted as circumstances warrant, but at least annually.
7. Where political instability, terrorism, host country attitudes, or criminal activity suggests the possibility that a SCIF may be overrun, emergency plans shall include instructions for the secure destruction or removal of SCI under adverse circumstances and include contingencies for loss of electrical power and non-availability of open spaces for burning or chemical decomposition of material.
8. Where the risk of hostile actions are significant, SCI holdings and reference materials shall be maintained at an absolute minimum required for current working purposes. If reference or other material is needed, it shall be obtained from other activities and returned or destroyed when no longer needed.
Chapter 13
Forms and Plans
Chapter 13. Forms and Plans
Fixed Facility Checklist
TEMPEST Checklist
Compartmented Area Checklist
Shipboard Checklist
Submarine Checklist
Aircraft/UAV Checklist
SCIF Co-Use Request and MOA
Construction Security Plan (CSP)
SCIF Fixed Facility Checklist
CLASSIFIY ACCORDING TO CLASSIFICATION AUTHROITY
CHECK Applicable blocks
□ Domestic □ Overseas Not COM □ Overseas COM
□ Pre-construction, Complete
Sections as Required by A/O
□ Final FFC Accreditation □ Update/Page Change
Checklist Contents
Section A: General Information
Section B: Security-in-Depth
Section C: SCIF Security
Section D: Doors
Section E: Intrusion Detection Systems (IDS)
Section F: Telecommunication Systems and Equipment Baseline
Section G: Acoustical Protection
Section H: Classified Destruction Methods
Section I: Information Systems/TEMPEST/Technical Security
List of Attachments
-- TEMPEST Checklist
-- Diagrams and Other Attachments as Required
FFC Date:
Organization Name:
Section A: General Information
1. SCIF Data
Organization/Company Name
SCIF Identification Number (if applicable)
Organization subordinate to (if applicable)
Contract Number & Expiration Date (if applicable)
Concept approval Date/by (if applicable)
Cognizant Security Authority (CSA)
Defense Special Security Communication System Information (if applicable)
DSSCS Message Address
DSSCS INFO Address
If no DSSCS Message Address, please provide passing instructions
2. SCIF Location
Street Address Building Name
Floor(s) Suite(s) Room(s) #
City Base/Post
State/Country Zip Code
3. Mailing Address (if different from SCIF location)
Street or Post Office Box
City State Zip Code
4. Responsible Security Personnel
PRIMARY ALTERNATE
Name
Commercial Phone
DSN Phone
Secure Phone
STE Other Phone
Home
Secure Fax
Command or Regional Special Security Office/Name (SSO) (if applicable)
Commercial Phone
Other Phone
5. E-Mail Address of Responsible Security Personnel
Classified Network/System Name & Level
Unclassified Network/System Name
Other Network/System Name
6. Accreditation Data (Ref Chapter: 12E)
a. Category/Compartments of SCI Requested:
1) Indicate storage requirement:
□ Open □ Closed □ Continuous Operation □ None
2) Indicate the facility type
□ Permanent □ Temporary □ Secure Working Area □ TSWA
3) Co-Use Agreements □ Yes □ No
If yes, provide sponsor:
b. SAP(s) co-located within SCIF □ Yes □ No
If yes, identify SAP Classification level (check all that apply)
□ SCI □ Top Secret □ Secret □ Confidential
c. SCIF Duty Hours Hours to Hours: Days Per Week:
d. Total square footage that the SCIF occupies:
e. Has or will CSA requested any waivers? □ Yes □ No □ N/A
If yes, attach a copy of approved waiver
7. Construction/Modification (Ref: Chapter 3B)
a. Is construction or modification complete? □ Yes □ No □ N/A
If no, enter the expected date of completion:
b. Was all construction completed in accordance with the CSP? □ Yes □ No □ N/A
If NO, explain:
8. Inspections (Ref: Chapter 12G) (ALL INSPECTION REPORTS MUST BE ATTAHCED)
Has a TSCM Inspection been performed? □ Yes □ No
If yes, provide the following:
b. TSCM Service completed by: On
Were deficiencies corrected? □ Yes □ No □ N/A
If NO, explain:
a.
c. Last physical security inspection by: On
Were deficiencies corrected? □ Yes □ No □ N/A
If NO, explain:
d. Last Staff Assistance Visit by: On
9. REMARKS:
Section B: Security-in-Depth
1. Describe building exterior Security (Ref: Chapter 2B)
a. Is the SCIF located on a military installation, embassy compound, USG compound or contractor compound with a dedicated U.S. person response force? □ Yes □ No
b. Is the SCIF located in an entire Building □ Yes □ No
c. Is the SCIF located on a single floor of Building □ Yes □ No
d. Is the SCIF located in a secluded area of Building □ Yes □ No
e. Is the SCIF located on a fenced compound with access controlled vehicle gate and/or pedestrian gate? □ Yes □ No
f. Fence Type
1) Height:
2) Does it surround the compound? □ Yes □ No
3) How is it controlled?
4) How many gates?
5) Hours of usage?
6) How are they controlled when not in use?
Is the Fence Alarmed? □ Yes □ No
If so, describe alarm systems (i.e. - Microwave)
g. Exterior Lighting Type:
1) Fence Lighting
2) Building Lighting
h. Is there external CCTV coverage? □ Yes □ No
If so, describe the CCTV system. (include monitor locations on map)
i. Exterior Guards □ Yes □ No
1) What kind of patrols are they? □ Static □ Roving
Clearance level of guards (if applicable)
During what hours/days?
□ Yes □ No
If yes, describe duties:
NoYesAny SCIF duties?
2)
3)
4)
□ SCI □ Top Secret □ Secret
2. Describe Building Security (Please provide legible general floor plan of the SCIF perimeter)
Is the SCIF located in a controlled building with separate access controls, alarms, elevator controls, stairwell control, etc. required to gain access to building or elevator?
□ Yes □ No
If yes, is SCIF controlled by bldg owners? □ Yes □ No
If controlled by SCIF owners, is alarm activation reported to SCIF owners by agreement? □ Yes □ No
b. Construction Type
c. Windows
d. Doors
e. Describe Building Access Control: Continuous? □ Yes □ No
If no, during what hours?
f. Clearance level of guards (if applicable) □ SCI □ Top Secret □ Secret
1) Any SCIF duties? □ Yes □ No
If yes, describe duties?
During what hours/days?
3. Describe Building Interior Security
Are office areas adjacent to the SCIF controlled and alarmed? □ Yes □ No
If yes, describe adjacent areas and types of alarm systems.
Controlled by SCIF Owner? □ Yes □ No
If controlled by Bldg owner, alarm activation reported to SCIF owner by agreement? □ Yes □ No
4. Security In-Depth
What external security attributes and/or features should the AO consider before determining whether or not this facility has Security In-Depth? Please identify/explain all factors:
Remarks:
a.
b.
a.
Section C: SCIF Security
1. How is access to the SCIF controlled (Ref: Chapter 8)
a. By Guard Force □ Yes □ No
If yes, what is their minimum security clearance level? □ SCI □ Top Secret □ Secret
b. Is Guard Force Armed? □ Yes □ No □ N/A
c. By assigned personnel? □ Yes □ No
If yes, do personnel have visual control of SCIF entrance door? □ Yes □ No
d. By access control device? □ Yes □ No
If yes, what kind? □ Automated access control system □ Non-Automated
If Non-Automated
1. Is there a by-pass key? □ Yes □ No □ N/A
If yes, how is the by-pass key protected?
2. Manufacturer: Model:
(Explain in Remarks if more space is required)
If Automated
1. Is there a by-pass key? □ Yes □ No □ N/A
If yes, how is the by-pass key protected?
2. Manufacturer: Model:
(Explain in Remarks if more space is required)
3. Are access control transmission lines protected by 128-bit encryption/FIBS 140? □ Yes □ No
If no, explain the physical protection provide
4. Is automated access control system located within a SCIF or an alarmed area controlled at the SECRET level?
□ Yes □ No
5. Is the access control system encoded and is ID data and PINs restricted to SCI-indoctrinated personnel?
□ Yes □ No
6. Does external access control outside SCIF have tamper protection? □ Yes □ No
7. Is the access control device integrated with IDS □ Yes □ No □ N/A
8. Is the access control device integrated with a LAN/WAN System? □ Yes □ No □ N/A
2. Does the SCIF have windows? (Ref: Chapter 3F)
a. Are they acoustically protected? □ Yes □ No □ N/A
If Yes, explain:
b. Are they secured against forced entry? □ Yes □ No □ N/A
If Yes, explain:
c. Are they protected against visual surveillance? □ Yes □ No □ N/A
If Yes, explain:
3. Do ventilation ducts penetrate the SCIF perimeter? (Ref: Chapter 3G) □ Yes □ No
(Indicate all duct penetrations and their size on a separate floor plan as an attachment)
a. Any ducts over 96 square inches that penetrate perimeter walls? □ Yes □ No
If yes, how are they protected? □ IDS (Describe in Section E) □ Bars/Grills/Metal /Baffles
If Other, Describe Protection:
b. Inspection ports? □ Yes □ No
If yes, are they within the SCIF? □ Yes □ No
If no, are they secured? □ Yes □ No
If No, explain:
c. Do all ventilation ducts penetrating the perimeter meet acoustical requirements? □ Yes □ No
(NOTE: All ducts and vents, regardless of size may require acoustical protection)
If yes, how are they protected? □ Metal Baffles □ Noise Generator □ Z-Duct
If Other, Describe Protection:
3. Construction (Ref: Chapter 3B)
a. Describe Perimeter Wall Construction:
b. True ceiling (material and thickness)? □ Yes □ No
If Yes, What is the material and thickness:
c. False ceiling? □ Yes □ No
1) If yes, what is the type of ceiling material?
2) What is the distance between false and true ceiling?
d. True floor (material and thickness)? □ Yes □ No
If Yes, What is the material and thickness:
e. False floor? □ Yes □ No
1) If yes, what is the type of false flooring?
2) What is the distance between false and true floor?
4. REMARKS:
Section D: Doors
1. Describe SCIF primary entrance door construction (Ref: Chapter 3E)
(Indicate door locations and types floor plan as an attachment)
a. Does the door and doorframe meet sound attenuation requirements? □ Yes □ No
If no, have acoustical countermeasures been employed? □ Yes □ No
b. Describe SCIF perimeter doors to include thickness and type of door.
c. Is an automatic door closer installed? □ Yes □ No
If NO, explain:
d. Is a door sweep/thresholds installed? □ Yes □ No
If NO, explain:
e. Is an acoustical/astragal strip installed? □ Yes □ No
If NO, explain:
2. Describe number and type of doors used for SCIF emergency exits and other perimeter doors including day access
a. Do the doors and doorframes meet sound attenuation requirements? □ Yes □ No
If no, have acoustical countermeasures been employed? □ Yes □ No
b. Has exterior hardware been removed? □ Yes □ No
c. Has local enunciator been installed? □ Yes □ No
d. Describe how the door hinges exterior to the SCIF are secured against removal (if in an uncontrolled area).
3. Locking Devices
a. Is the primary entrance door equipped with a GSA-approved pedestrian door deadbolt meeting Federal Specification FF-L-2890 including lock meeting FF-L-2740A
□ Yes □ No
b. List combination lock manufacturer, model number and group rating
Manufacturer:
Model Number:
Group Rating:
c. Does the entrance door stand open into an uncontrolled area? □ Yes □ No
If yes, please describe tamper protection.
d. Emergency exits and other perimeter doors: Describe (locks, metal strip/bar, deadbolts, local annunciation, and panic hardware).
e. Where is the lock combination(s) filed? (Please identify the SCIF AO and SCIF ID#)
4. REMARKS:
Section E: Intrusion Detection Systems
1. General IDS Description (Ref: Chapter 7A)
a. Has the IDS configuration been approved by the AO? □ Yes □ No
Identity of IDS installer:
IDS monitoring firm:
c. Premise Control Unit (PCU)
Manufacturer Model Number
Tamper Protection □ Yes □ No
Is the PCU located inside the SCIF perimeter (indicated on floor plan)? □ Yes □ No
If no, please explain b.
d.
e. Location of interior motion detection protection
Accessible points of entry/perimeter? □ Yes □ No
Any others? Explain;
f. Has the IDS alarm monitor station been installed to Underwriters Laboratories certified standards?
□ Yes □ No
Contractor facility submit copy of Certificate
g. Has the IDS passed AO or UL 2050 installation and acceptance tests? □ Yes □ No
If yes, attach a copy of certificate (Non-commercial proprietary system must answer all questions)
h. High Security Switches Type I □ Yes □ No
i. High Security Switches Type II □ Yes □ No
j. Motion sensor (indicate sensor placement on a legible floor)
k. Are any other intrusion detection equipment sensors/detectors in use?
□ Yes □ No
Please identify make, model and manufacturer and function (indicate on floor plan)
Make Model Manufacturer Function
l. Does the IDS extend beyond the SCIF perimeter? □ Yes □ No
m. Can the status of PCU be changed from outside IDS protection? □ Yes □ No
If yes, is an audit conducted daily? □ Yes □ No
n. Do any intrusion detection equipment components have audio or video capabilities?
□ Yes □ No
If yes, please explain.
o. PCU administrator SCI indoctrinated? □ Yes □ No
p. Is external Transmission Line Security used? □ Yes □ No
If yes, please explain.
q. What is the method of line security? National Institute of Standards and Technology
(NIST) FIBS AES encryption? □ Yes □ No
1) If yes, has the encryption been certified by NIST or another independent testing laboratory? □ Yes □ No
2) If not NIST standard, is there an alternate? □ Yes □ No
If yes, please explain.
4) Does the alternate line utilize any cellular or other Radio Frequency (RF) capability? □ Yes □ No
Manufacturer Model Number
r. Does any part of the IDS use local or wide area network (LAN/WAN)? □ Yes □ No □ N/A
1) Is the host computer dedicated solely for security purposes? □ Yes □ No □ N/A
2) Is the host computer secured within an alarmed area at the SECRET or higher level?
□ Yes □ No □ N/A
3) Is the host computer protected through firewalls or similar devices? □ Yes □ No □ N/A
4) Is the password for the host computer unique for each user and at least 8-characters long consisting of alpha, numeric, and special characters?
□ Yes □ No □ N/A
5) Is the password changed semi-annually? □ Yes □ No □ N/A
6) Are remote security terminals protected the same as the host computer? □ Yes □ No □ N/A
2. Is emergency power available for the IDS? □ Yes □ No □ N/A
Generator? □ Yes □ No If yes, how many hours?
Battery? □ Yes □ No If yes, how many hours?
3. Where is the IDS alarm monitor station located?
4. Does the monitor station have any remote capabilities (i.e., resetting alarms, issuing PINs, accessing/securing alarms, etc.? □ Yes □ No □ N/A
If yes, please explain:
5. Does the IDS have any automatic features (i.e., timed auto-secure, auto-access capabilities? □ Yes □ No □ N/A
6. Does the PCU/keypad have dial out capabilities? □ Yes □ No □ N/A
7. IDS response personnel □ Yes □ No □ N/A
a. Who provides initial alarm response?
b. Does the response force have a security clearance? □ Yes □ No
If yes, what is the clearance level? □ SCI □ Top Secret □ Secret
c. Do you have a written agreement with external response force? □ Yes □ No
d. Emergency procedures documented? □ Yes □ No
e. Response to alarm condition: Minutes
f. Are response procedures tested and records maintained? □ Yes □ No
If no, please explain:
g. Has a catastrophic failure plan been approved by the CSA? □ Yes □ No
If no, please explain:
If no, please explain:
10. REMARKS:
Section F: Telecommunication Systems and Equipment Baseline
1. Is the facility declared a ‘‘No Classified Discussion Area’’? (Ref: Chapter 11A) □ Yes □ No
If yes, then the audio protection questions within this section may be identified as N/ A
If the facility is declared a ‘‘No Classified Discussion Area’’, are warning notices posted prominently within the facility?
□ Yes □ No □ N/ A
2. Does the facility have any unclassified telephones that are connected to the commercial public switch telephone network (PSTN)?
□ Yes □ No
Identify the method of on-hook protection by completing items below NOTE: TSG 6 approved phones can be found at the following link:
https://www.dni.gov/files/NCSC/documents/products/TSG-Approved-Equipment-List-May-2017.pdf
a. CNSSI 5006 (TSG-6) approved telephone or instrument □ Yes □ No □ N/ A
(Please identify all telephone equipment/stations and/or instruments being used either below or as an attachment)
Manufacturer Model Number TSG Number (if applicable)
b. CNSSI 5006 (TSG-6) approved d isconnect device? □ Yes □ No □ N/ A
1) Line d isconnect? □ Yes □ No □ N/ A
2) Ringer protection? □ Yes □ No □ N/ A
Manufacturer Model Number TSG Number (if applicable)
c. CNSSI 5002 (TSG-2) configured computerized telephone system (CTS)? □ Yes □ No □ N/ A
1) If yes, please provide the following information about the CTS
Manufacturer Model
2) If yes, please provide specific location of the CTS
3) Is the facility protecting the CTS physically controlled?
If yes, what is the clearance level (if any) of facility or a rea where the switch is located .
□ SCI □ Top Secret □ Secret
If no facility clearance level how is the facility or area where the switch is located controlled?
4) How are all cables, signal lines and intermediate writing frames between the SCIF telephones and the CTS physically protected within a physically controlled space?
5) Are all program media, such as tapes and/ or d isks, from the CTS afforded physical protection from unauthorized alterations?
□ Yes □ No
6) Is an up-to-date master copy of the CTS software program maintained for confirmation and/ or reloading of the operating system?
□ Yes □ No
7) Does the CTS have the capability to force or hold a telephone station off-hook? □ Yes □ No
8) Does the CTS use remote maintenance and diagnostic procedures or other remote access features?
□ Yes □ No
If yes, explain maintenance procedures
9) Do the CTS installers and programmers have security clearances? □ Yes □ No
If yes, at what access level (minimum established by AO) □ SCI □ Top Secret □ Secret
If no, are escorts provided? □ Yes □ No
d. Is it a Voice over Internet Protocol (VOIP) phone system (IPS) (Ref CNSSI 5000)?
□ Yes □ No □ N/ A
1) If yes, p lease provide the following information about the IPS
Manufacturer Model Number IPS Location
2) Do all unclassified telephones within the facility have a hold , mute and/ or push-to-talk [handset] capability, (for off-hook audio protection)?
□ Yes □ No □ N/ A
If no, please explain?
3) Is access to the facility housing the IPS physically controlled? □ Yes □ No
If yes, what is the clearance level (if any) of facility or area where the switch is located and how is the area controlled?
□ SCI □ Top Secret □ Secret
If no facility clearance level how is the facility or area where the IPS is physically located controlled
4) Are all cables, signal lines and intermediate wiring frames between the SCIF telephones and the IPS physically protected or contained within a physically controlled space?
□ Yes □ No
If no, please explain?
5) Are all program media, such as tapes and/ or disks, from the IPS afforded physical protection from unauthorized alterations?
□ Yes □ No
6) Is an up-to-date master copy of the IPS software program maintained for confirmation and/ or reloading of the operating system?
□ Yes □ No
7) Does the IPS have the capability to force or hold a telephone station off-hook? □ Yes □ No
8) Does the IPS use remote maintenance and diagnostic procedures or other remote access features?
□ Yes □ No
9) Do the IPS installers and programmers have security clearances? □ Yes □ No
If yes, at what access level (minimum established by AO)? □ SCI □ Top Secret □ Secret
If no, are escorts provided? □ Yes □ No
3. Automatic telephone call answering
a. Are there any automatic call answering devices for the telephones in the SCIF? □ Yes □ No
1) If yes, please identify the type
Voicemail/ unified message service? □ Yes □ No
Standalone telephone answering device (TAD)? □ Yes □ No
2) Provide manufacturer and model number of the equipment
Manufacturer Model
b. Are speakerphones/ microphones enabled? □ Yes □ No
If yes, has the remote room monitoring capability been disabled? □ Yes □ No
Has this been approved for use by…