ATTACHMENT_25_GwangJu_ITN_Floor_Plan_Drawings.pdf

PDF 116 KB Posted

Attached to
Gwangju Communications Infrastructure Engineering and Installation
Solicitation number
W91QVN-19-R-0295
Issued by

About this file

ATTACHMENT # 25_Gwangju_ITN Floor Plan

View the file

Other files

File Type Posted
W91QVN-19-D-0295_0003.pdf PDF
W91QVN-19-R-0295-0002.pdf PDF
ATTACHMENT_27-Govt_Response_to_Contractors_Questions.-Gwangju.xlsx XLSX spreadsheet
W91QVN-19-R-0295-0001.pdf PDF
ATTACHMENT_3__Gwangju_&_45800;&_52404;_&_51068;&_44292;_&_48124;&_44036;&_51064;_&_52636;&_51077;&_49888;&_52397;_&_50577;&_49885;(2003).xls XLS spreadsheet
ATTACHMENT_24_Gwangju_AB_OSP_One-line_Diagram.pdf PDF
ATTACHMENT_4_Supplemental_Price__Sheet.xlsx XLSX spreadsheet
W91QVN-19-R-0295-27_Sept_19.pdf PDF
ATTACHMENT_5B__Building.pdf PDF
ATTACHMENT_22_Maps.pdf PDF
ATTACHMENT_26_Visio-Rack_drawing-2.pdf PDF
ATTACHMENT_8_Building.pdf PDF
ATTACHMENT_14_Building.pdf PDF
ATTACHMENT_15_Building.pdf PDF
ATTACHMENT_20_Maps.pdf PDF
ATTACHMENT_10_Building_.pdf PDF
ATTACHMENT_9_Building.pdf PDF
ATTACHMENT_23_Maps.pdf PDF
ATTACHMENT_7_Building.pdf PDF
ATTACHMENT_11_Building.pdf PDF
ATTACHMENT_17_Manhole-Handhole.pdf PDF
ATTACHMENT_5C__Building.pdf PDF
ATTACHMENT_21_Maps_.pdf PDF
ATTACHMENT_13_Building.pdf PDF
ATTACHMENT_12_Building.pdf PDF
ATTACHMENT_2_EDP_GwangJu_Revision_30JULY2019.docx DOCX document
ATTACHMENT_19_Manhole-Handhole.pdf PDF
ATTACHMENT_1_-_Past_Performance_Questionnaire_(PPQ).docx DOCX document
ATTACHMENT_18__Manhole-Handhole.pdf PDF
ATTACHMENT_16_Manhole-Handhole.pdf PDF
ATTACHMENT_5A__Building.pdf PDF
ATTACHMENT_6_Building.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

607MMS/DET1

GWANGJU

Building 1808 ‐Existing

SIZE FSCM NO DWG NO REV

DRAWN SMSGT MEDENY GUY A ‐ MMFZ‐B1808‐EXISTING ROOM LAYOUT ‐

ISSUED 24 MAY 2019 SCALE NONE SHEET 1 OF 4

ROOM 105

29'

Old Keyboards LGU+ MAR

FORK KT AN/FCC

98V

AN/FCC

98V

Old Patch Panel

Storage cabinet

OLD

WIRE

WRAP

FRAME

3'

2'

2'

8'

Old Switch

RR207

2.5'

Northern Telecom

APC Remote

Term. VOIP #1

Term. VOIP #2

2'

15'

3' 3.25'

RR306

2'

RR308

3'

4'

Cable Entryway

3'

1'

FOR OFFICIAL USE ONLY607MMS/DET1

Building 1808 ‐ New configuration

SIZE FSCM NO DWG NO REV

DRAWN SMSGT MEDENY GUY A ‐ MMFZ‐B1808‐NEW ITN ROOM LAYOUT ‐

ISSUED 24 MAY 2019 SCALE NONE SHEET 2 OF 4

ROOM 105

29'

Old Keyboards LGU+ MAR

FORK KT

New Relay Rack

New Relay Rack

OLD

WIRE

WRAP

FRAME

3'

2'

8'

Old Switch

RR207

2.5'

Northern Telecom

APC Remote

Term. VOIP #1

Term. VOIP #2

2'

15'

3' 3.25'

RR306

2'

RR308

3'

4'

Alternate Relay Rack

Alternate Relay Rack

1'

3'

Cable Entryway

4'

B P O C

Fiber Rack

Fiber Rack

P A N E L B O A R D

GBB

CAT6

Patch Panel

EMPTY

EXISTING

B P O C

Fiber Rack

Fiber Rack

P A N E L B O A R D

GBB

CAT6

Patch Panel

Re‐use as FIBER

RACK

NEW

FOR OFFICIAL USE ONLY607MMS/DET1

GWANGJU

Building 2159 ‐ Room configuration

SIZE FSCM NO DWG NO REV

DRAWN SMSGT MEDENY GUY A ‐ MMFZ‐B2159‐ITN ROOM ‐

ISSUED 24 MAY 2019 SCALE NONE SHEET 1 OF 3

11'

11'

11'

Ductless A/C Unit

Ductless A/C Unit 2'

Power Power

Cable Entryway Above

False Ceiling

Cable Entryway Above

False Ceiling

ISP Cable Entryway

ISP Cable Entryway

Building 246 ‐ Room Configuration

SIZE FSCM NO DWG NO REV

DRAWN SMSGT MEDENY GUY A ‐ MMFZ‐B246‐ITN ROOM LOCATION ‐

ISSUED 24 MAY 2019 SCALE NONE SHEET 1 OF 4

9'

9'

EXISTING

Temp

ISP

PATIO

CE Requirements/Addition to PWS

‐ Reverse opening to outside (full use of room) ‐ Keylock ‐ A/C unit within room ‐ Back‐up power/UPS ‐ Additional lighting

Building 246 ‐New

SIZE FSCM NO DWG NO REV

DRAWN SMSGT MEDENY GUY A ‐ MMFZ‐B246‐NEW ITN ROOM ‐

ISSUED 24 MAY 2019 SCALE NONE SHEET 5 OF 7

9'

9'

CE Requirements/Addition to PWS

‐ Reverse opening to outside (full use of room) ‐ Keylock ‐ A/C unit within room ‐ Back‐up power/UPS ‐ Additional lighting

New Relay Rack

O/H HVAC

GWANGJU

Building 1427 ‐ Room configuration

SIZE FSCM NO DWG NO REV

DRAWN SMSGT MEDENY GUY A ‐ MMFZ‐B1427‐ITN ROOM ‐

ISSUED 24 MAY 2019 SCALE NONE SHEET 1 OF 2

O L D

P B X

8'

12' W al l‐m ou nt ed

Ca bi ne ts

EXISTING

O L D

P B X

8'

12'

3' x 6'

CE Requirements/Addition to PWS

‐ Keylock entry (compatible to other ITNs) ‐ Back‐up power/UPS (In works as Alt. CP) ‐ Blackout window ‐ Cable entry pt

Ca bl e

En tr yNEW

Overhead

HVAC

Unit New

Relay Rack

3'

3'

Tinted Window 3' x 6'

Building PB‐4 ‐ Room configuration

SIZE FSCM NO DWG NO REV

DRAWN SMSGT MEDENY GUY A ‐ MMFZ‐BPB‐4‐ITN ROOM ‐

ISSUED 24 MAY 2019 SCALE NONE SHEET 1 OF 2

CE Requirements/Addition to PWS

‐ Reverse opening to outside (full use of room) ‐ Keylock ‐ A/C unit within room ‐ Back‐up power/UPS ‐ Additional lighting ‐ Ground Busbar

5'

5.1'

P A N

EL

B O A R D

Switch/ Router Rack

2'

5'

5.1'

P A N

EL

B O A R D

Switch/ Router Rack

2'

EXISTING NEW