F5W61608 USPFO Warehouse Ohio Army National Guard Rev. 0 Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
WIRE MESH PARTITIONS 106050 - 1
SECTION 106050 - WIRE MESH PARTITIONS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Standard-duty wire mesh partitions.
1.2 SUBMITTALS
A. Product Data: For each type of product indicated.
B. Shop Drawings: Include plans, elevations, sections, details, and attachments to other work.
C. Samples: For each exposed product and for each color and texture specified.
D. Maintenance data.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
1. Acorn Wire & Iron Works, Inc.
2. American Woven Wire Corporation.
3. G-S Company (The).
4. Miller Wire Works, Inc.
5. Standard Wire & Steel Works.
6. Wire Crafters, LLC.
2.2 MATERIALS
A. Steel Wire: ASTM A 510.
B. Steel Plates, Channels, Angles, and Bars: ASTM A 36.
C. Cold-Rolled Steel Sheet: ASTM A 1008, Commercial Steel (CS), Type B.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
WIRE MESH PARTITIONS 106050 - 2
D. Steel Pipe: ASTM A 53, Schedule 40 unless another weight is indicated or required by structural loads.
E. Square Steel Tubing: ASTM A 500, cold-formed structural-steel tubing.
F. Metallic-Coated Steel Sheet: ASTM A 653, Commercial Steel (CS), Type B; with G60 zinc (galvanized) or A60 zinc-iron-alloy (galvannealed) coating designation.
G. Panel-to-Panel Fasteners: Manufacturer's standard steel bolts, nuts, and washers.
H. Power-Actuated Fasteners in Concrete: Fastener system of type suitable for application indicated and fabricated from corrosion-resistant materials; with clips or other accessory devices for attaching hangers of type indicated, and with capability to sustain, without failure, a load equal to 10 times that imposed by wire mesh construction, as determined by testing per ASTM E 1190, conducted by a qualified testing and inspecting agency.
I. Seismic Bracing: Angles with legs not less than 1-1/4 inch wide, formed from 0.04-inch- thick, metallic-coated steel sheet; with bolted connections and 1/4-inch- diameter bolts.
J. Universal Shop Primer: Fast-curing, lead- and chromate-free, universal modified-alkyd primer, complying with MPI#79.
2.3 STANDARD-DUTY WIRE MESH PARTITIONS
A. Mesh: 0.135-inch- diameter, intermediate-crimp steel wire woven into 1-1/2-inch diamond mesh.
B. Vertical Panel Framing: 1-1/4-by-5/8-by-0.097-inch cold-rolled, C-shaped steel channels with 1/4-inch- diameter bolt holes spaced not more than 18 inches o.c. along center of framing.
C. Horizontal Panel Framing: 1-by-1/2-by-1/8-inch cold-rolled steel channels.
D. Horizontal Panel Stiffeners: 2 cold-rolled steel channels, not less than 1 by 3/8 by 1/8 inch, bolted or riveted toe to toe through mesh or 1-by-1/2-by-1/8-inch cold-rolled steel channels with wire woven through.
E. Top Capping Bars: 2-1/4-by-1-inch cold-rolled steel channels.
F. Posts for 90-Degree Corners: 1-1/4-by-1-1/4-by-1/8-inch steel angles with 1/4-inch-diameter bolt holes aligning with bolt holes in vertical framing; with floor anchor clips.
G. Posts for Other-Than-90-Degree Corners: Manufacturer's standard steel pipe or tubing with 1/4-inch- diameter bolt holes aligning with bolt holes in vertical framing.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
WIRE MESH PARTITIONS 106050 - 3
1. Partitions up to 12 Feet High: 1-1/4-inch OD.
H. Line Posts: 3-inch-by-4.1-lb or 3-1/2-by-1-1/4-by-0.127-inch steel channels; with 5-by- 18-by-1/4-inch steel base plates punched for attachment to floor.
I. Floor Shoes: Steel, cast iron, or cast aluminum, not less than 2 inches high; sized to suit vertical framing, drilled for attachment to floor, and with set screws for leveling adjustment.
J. Swinging Doors: Fabricated from same mesh as partitions, with framing fabricated from 1-1/4-by-1/2-by-1/8-inch steel channels or C-channels, banded with 1-1/4-by-1/8-inch flat steel bar cover plates on 3 sides, and with 1/8-inch- thick angle strike bar and cover on strike jamb.
1. Hinges: Full-surface type, 3-by-3-inch steel, 1-1/2 pairs per door; bolted, riveted, or welded to door and jamb framing.
2. Cylinder Lock: Mortise type with cylinder specified in Division 8 Section "Door Hardware"; operated by key outside and knob inside.
K. Finish for Uncoated Ferrous Steel: Hot-dip galvanized, where indicated, and shop primed for powder-coated finish.
1. Color: As selected by Architect from manufacturer's full range.
2.4 FABRICATION
A. General: Fabricate wire mesh items from components of sizes not less than those indicated. Use larger-sized components as recommended by wire mesh item manufacturer. As required for complete installation, provide bolts, hardware, and accessories with manufacturer's standard finishes.
1. Fabricate wire mesh items to be readily disassembled.
2. Welding: Weld corner joints of framing and grind smooth, leaving no evidence of joint.
B. Standard-duty Wire Mesh Partitions: Fabricate wire mesh partitions with cutouts for pipes, ducts, beams, and other items indicated. Finish edges of cutouts to provide a neat, protective edge.
1. Mesh: Securely clinch mesh to framing.
2. Framing: Fabricate framing with mortise and tenon corner construction.
a. Provide horizontal stiffeners as indicated or, if not indicated, as required by panel height and as recommended by wire mesh partition manufacturer.
Weld horizontal stiffeners to vertical framing.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
WIRE MESH PARTITIONS 106050 - 4
b. Fabricate partition and door framing with slotted holes for connecting adjacent panels.
3. Fabricate wire mesh partitions with 3 inches of clear space between finished floor and bottom horizontal framing.
4. Fabricate wire mesh partitions with bottom horizontal framing flush with finished floor.
5. Doors: Align bottom of door with bottom of adjacent panels.
a. For doors that do not extend full height of partition, provide transom over door, fabricated from same mesh and framing as partition panels.
6. Hardware Preparation: Mortise, reinforce, drill, and tap doors and framing as required to install hardware.
2.5 STEEL AND IRON FINISHES
A. Powder-Coat Finish: Immediately after cleaning and pretreating, apply manufacturer's standard 2-coat, baked-on finish, suitable for use indicated, consisting of prime coat and thermosetting topcoat, with a minimum dry film thickness of 1 mil for topcoat.
PART 3 - EXECUTION
3.1 WIRE MESH PARTITIONS ERECTION
A. Anchor wire mesh partitions to floor with 3/8-inch- diameter, anchors at 12 inches o.c.
through floor shoes located at each post and corner. Adjust wire mesh partition posts in floor shoes to achieve level and plumb installation.
B. Anchor wire mesh partitions to walls at 12 inches o.c. through back corner panel framing with fasteners appropriate to substrate.
C. Secure top capping bars to top framing channels with 1/4-inch- diameter "U" bolts spaced not more than 28 inches o.c.
D. Provide line posts at locations indicated.
E. Provide seismic supports and bracing as indicated or, if not indicated, as recommended by manufacturer and as required for stability, extending and fastening members to supporting structure.
F. Where standard-width wire mesh partition panels do not fill entire length of run, provide adjustable filler panels to fill openings.
G. Install doors complete with door hardware.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
WIRE MESH PARTITIONS 106050 - 5
3.2 ADJUSTING AND CLEANING
A. Adjust doors to operate smoothly and easily, without binding or warping. Adjust hardware to function smoothly. Confirm that latches and locks engage accurately and securely without forcing or binding.
B. Touchup Painting: Immediately after erection, clean field welds, bolted connections, and abraded areas. Paint uncoated and abraded areas with the same material as used for shop painting to comply with SSPC-PA 1 for touching up shop-painted surfaces.
END OF SECTION 10605