General_Civil_and_Telecommunications_10-4-17(3)DCANG.pdf

PDF 25 MB Posted

Attached to
MUNITION LOAD CREW TRAINING FACILITY
Solicitation number
W912R1-19-B-5002
Issued by

About this file

Drawings - General - Civil and Telecommunications

View the file

Other files

Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMUNICATIONS COMBINATION

VOICE/DATA OUTLET

(FOUR DATA JACKS) MOUNT 18" AFF,

UIO

COMMUNICATIONS VOICE OUTLET

MOUNT 18" AFF, UIO

COMMUNICATIONS DATA OUTLET,

MOUNT 18" AFF, UIO

COAXIAL CATV OUTLET WALL

MOUNTED 60" AFF, UIO

WALL MOUNTED JUNCTION BOX FOR

VOICE/DATA CONNECTION TO

MODULAR WORKSTATION FURNITURE.

COAXIAL CATV OUTLET

CEILING MOUNTED

SYMBOL DESCRIPTION

TV

COMMUNICATIONS

ACCESS CONTROL

JUNCTION BOX

AC

SECURITY

CABLE TRAY (SIZE AS INDICATED ON PLAN)

WIRING

J

GIANT VOICEGV

ELECTRIC LOCKEL

CARD READERCR

ABBREVIATIONS

A OR AMP

AFF

AWG

BCW

BLDG

C

CAT

CFCI

CU

D

DDC

EC

EF

EIA/TIA

EMT

EQUIP

FWE

G OR GND

GFGI

GFI

H

HVAC

IDS

IMC

J OR JB

K

KV

KVA

KW

L

LAN

MAX

MIN

MM

MT or MTD N

NEC

NEMA

NFPA

NTS

PVC

RMC

SA

SM

SPEC

TMGB

TP

TYP

UIO

UL

UTP

V

VA

W

AMPERE(S)

ABOVE FINISHED FLOOR

AMERICAN WIRE GAUGE

BARE COPPER WIRE

BUILDING

CONDUIT

CATEGORY

CONTRACTOR FURNISHED CONTRACTOR INSTALLED

COPPER

DEPTH OR DATA

DIRECT DIGITAL CONTROL FOR HVAC

EMPTY CONDUIT

ENTRANCE FACILITY

ELECTRONICS INDUSTRY ALLIANCE/

TELECOMMUNICATIONS INDUSTRY ASSOCIATION

ELECTRICAL METALLIC TUBING

EQUIPMENT

FURNISHED WITH EQUIPMENT

GROUND

GOVERNMENT FURNISHED GOVERNMENT INSTALLED

GROUND FAULT INTERRUPTER

HEIGHT

HEATING, VENTILATING & AIR CONDITIONING

INTRUSION DETECTION SYSTEM

INTERMEDIATE METAL CONDUIT

JUNCTION BOX

KILO

KILOVOLT

KILOVOLT-AMPERES

KILOWATT

LENGTH

LOCAL AREA NETWORK

MAXIMUM

MINIMUM

MULTI-MODE

MOUNT or MOUNTED

NEUTRAL

NATIONAL ELECTRICAL CODE

NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION

NATIONAL FIRE PROTECTION ASSOCIATION

NOT TO SCALE

POLYVINYL CHLORIDE

RIGID METAL CONDUIT

SURGE ARRESTOR

SINGLE MODE

SPECIFICATIONS

TELECOMMUNICATIONS MAIN GROUNDING BUSBAR

TWISTED PAIR

TYPICAL

UNLESS INDICATED OTHERWISE

UNDERWRITERS LABORATORY

UNSHIELDED TWISTED PAIR

VOLTS

VOLT AMPERES

WATTS or WIRE or WIDTH

GENERAL NOTES:

EQUIPMENT (PIPING, DUCTWORK, MACHINERY, ETC) THAT DOES NOT SERVE EF SHALL NOT BE

INSTALLED ABOVE OR IN IT SPACES, NOR SHALL THIS EQUIPMENT PASS THROUGH OR ENTER THE EF.

ANY MOTOR, TRANSFORMER OR OTHER ELECTRICAL DEVICE GREATER THAN 5KVA SHALL HAVE A

MINIMUM OF 47" SPACE SEPARATION FROM ANY WALL OF EF.

CONTRACTOR SHALL CAREFULLY COORDINATE WORK WITH ALL TRADES AND SHALL BE

RESPONSIBLE FOR SECURING SPACE REQUIREMENTS FOR TELECOMMUNICATIONS EQUIPMENT, AND

CORRECT ROUGH-IN LOCATIONS OF ELECTRICAL CONNECTIONS. CONTRACTOR SHALL ALSO

COORDINATE AND DETERMINE WHEN WORK SHALL BE INSTALLED IN ORDER TO AVOID CONFLICTS.

ANY REWORK REQUIRED DUE TO FAILURE TO COORDINATE THE TELECOMMUNICATIONS WORK WITH

OTHER TRADES SHALL BE AT NO ADDITIONAL COST TO THE GOVERNMENT.

VERIFY EXACT HEIGHT OF EACH COUNTER TOP AND BACKSPLASH ON ARCHITECTURAL DETAILS

AND/OR CASEWORK SHOP DRAIWNGS AND ADJUST SPECIFIED MOUNTING HEIGHT OF WALL OUTLETS TO LOCATE BOTTOM OF OUTLET BOX 4" ABOVE TOP OF BACKSPLASH; IF NO BACKSPLASH IS USED, LOCATE BOTTOM OF OUTLET BOX 6" ABOVE COUNTERTOP.

REFER TO DETAILS AND RISER DIAGRAMS FOR CABLE AND CONDUIT SIZES NOT SHOWN ON PLANS.

PROVIDE IS AN INCLUSIVE TERM USED TO DESCRIBE ASPECTS OF THE WORK TO BE

ACCOMPLISHED, AND IS HEREBY DEFINED TO REQUIRE CONTRACTOR TO STORE, FURNISH, INSTALL, MOUNT, CONNECT, CONTROL AND POWER EQUIPMENT INDICATED, AS WELL AS ALL

APPURTENANCES REQUIRED TO MAKE TELECOMMUNICATIONS SYSTEM OPERATE AS INDICATED

WTIHIN THESE DRAWINGS AND SPECIFICATIONS AND TO FULFILL THE SCOPE OF WORK.

PROVIDE WELDED WIRE TYPE CABLE TRAY IN ALL AREAS EXCEPT TR'S. PROVIDE LADDER TYPE

CABLE TRAY IN TR'S.

FLOOR BOXES AND POKE THRU'S SHALL BE SIZED TO NOT EXCEED TELECOMMUNICATION CABLE

MINIMUM BEND RADIUS.

EMT: COMPLY WITH ANSI C80.3 AND UL 797. ALL EMT SHALL BE FACTORY PAINTED. PROVIDE THE

FOLLOWING COLOR FOR EACH SYSTEM:

1. FIRE ALARM - RED

2. TELECOMMUNICATIONS - ORANGE

3. 480/277V POWER - YELLOW

4. 208/120V POWER - BLUE

5. SECURITY - PURPLE

1.

2.

3.

4.

5.

6.

7.

8.

9.

1 2 3 4 6

A

B

C

D

SHEET OF

SHEET ID

P a rk w a y L a n e S u it e

P e a c h tr e e

C o rn e rs

G

A

P h o n e

-7

F a x

-7

S

IZ

E

A

N S

I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

A N

G N

O

C O

N T

R A

C T

N O

F

IL

E N

U N

B E

R

A P

P R

D

E S

C R

IP

T

IO

N

M A

R K

E

D A

T E

S B

R

Professional Certification.

I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No.

Expiration Date:

/2 /2

:2

:5

P M

C R e v it L o c a l\

\1

D C

A N

G

M L C

T F

H

A N

G A

R

E L E

C

C E

N T

R A

L

R m a p

.r v t

T-001

TYPE B-3 (100%) SUBMITTAL - ISSUED FOR BID

T E

L E

C O

M S

Y M

B O

L S

M U

N

IT

IO

N

S L

O A

D C

R E

W T

R A

IN

IN

G F

A C

IL

IT

Y th

W

IN

G D

C A

N G

J O

IN

T

B A

S E

A N

D R

E W

S ,M

D

D

IS

T R

IC

T

O F

C O

L U

M B

IA

A

IR

N

A T

IO

N

A L

G U

A R

D

J O

B N

O

D e s ig n e r

A u th o r

C h e c k e r

O

C T

O B

E R

A J X

F

W

L

-1 -D

-0

X X

-X -X

X X

X

50902 05/11/19 parkerm Image

REF.

FD

CR

CR CR

CR

CR

GV

GV

GV

GV

GV

GV

GV

GV GV

GV

GV GV

GV GV

EL

EL

EL EL

EL

GV GV

DBA C

3.6

DDC

+48"

+48" +48"

+48"

E-401

C3 Sim

1 2 3 4 6

A

B

C

D

SHEET OF

SHEET ID

P a rk w a y L a n e S u it e

P e a c h tr e e

C o rn e rs

G

A

P h o n e

-7

F a x

-7

S

IZ

E

A

N S

I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

A N

G N

O

C O

N T

R A

C T

N O

F

IL

E N

U N

B E

R

A P

P R

D

E S

C R

IP

T

IO

N

M A

R K

E

D A

T E

S B

R

Professional Certification.

I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No.

Expiration Date:

/2 /2

:2

:5

P M

C R e v it L o c a l\

\1

D C

A N

G

M L C

T F

H

A N

G A

R

E L E

C

C E

N T

R A

L

R m a p

.r v t

T-101

TYPE B-3 (100%) SUBMITTAL - ISSUED FOR BID

T E

L E

C O

M P

L A

N

M U

N

IT

IO

N

S L

O A

D C

R E

W T

R A

IN

IN

G F

A C

IL

IT

Y th

W

IN

G D

C A

N G

J O

IN

T

B A

S E

A N

D R

E W

S ,M

D

D

IS

T R

IC

T

O F

C O

L U

M B

IA

A

IR

N

A T

IO

N

A L

G U

A R

D

J O

B N

O

M A

P

M A

P

J M

S

O

C T

O B

E R

A J X

F

W

L

-1 -D

-0

X X

-X -X

X X

X

SCALE: = 1'-0"

0 8 168

1/8"

SCALE: 1/8" = 1'-0"A2

TELECOMMINCATION FLOOR PLAN

SCALE: 1/8" = 1'-0"E2

TELECOMMINCATION FLOOR PLAN - FIRE PUMP HOUSE

SEE SHEET T-001 FOR GENERAL NOTES, ABBREVIATIONS AND

TELECOMMUNICATION SYMBOLS.

SEE SHEET T-601 FOR TELECOMMUNICATIONS RISER DIAGRAM.

THIS PROJECT SHALL PROVIDE DEVICE ROUGH-IN AND PATHWAYS ONLY FOR

ACCESS CONTROL SYSTEM. THE ACCESS CONTROL SYSTEM SHALL BE

FURNISHED AND INSTALLED UNDER A SEPARATE CONTRACT.

GENERAL NOTES:

1.

2.

3.

PROVIDE A 1 1/2" C FROM THE COMM ROOM UP TO THE ROOF STRUCTURE

AND EXIT OUT THE EXTERIOR WALL APPROXIMATELY 4' BELOW THE

HANGAR ROOF RIDGE. CONTRACTOR TO COORDINATE THE EXACT HEIGHT

OF THE CONDUIT THROUGH THE EXTERIOR WALL WITH CONTRACTING

OFFICERS REPRESENTATIVE.

12" WIDE X 4" DEEP BASKE TYPE CABLE TRAY.

KEY NOTES:

N

50902 05/11/19

RJ-45, CAT 6A

JACK, TYP FOR 4

EXTEND IN 1"C TO

NEAREST CABLE TRAY

OR ROUTE ON 'J'

HOOKS

CAT 6A UTP (BLUE JACKET) TYPICAL

DESIGNATION WINDOW (TYP.)

1-

D

101-13V

101-12D

WWW-XYZ

WWW = ROOM NO.

X = OUTLET NO.

Y = JACK NO.

Z = VOICE OR DATA

1-

D

MINIMUM 1" EMT CONDUIT

STUB-OUT 6" ABOVE WALL

AND ROUTE ON 'J' HOOKS TO

CABLE TRAY.

ROUTE CABLE TO TR. ROOM.

SINGLE OR DOUBLE

GANG EXTENSION.

CABLE PATHWAY HOME RUN

TO TR. SEE FLOOR PLANS

FOR ROUTING. (NOTE 4)

4-11/16" X 4-11/16" X 4"D

DOUBLE DEEP

JUNCTION BOX

(NOTE 1)

FACEPLATE

(LEVITON P/N 42080-4IS)

(NOTES 2 & 4)

TYPICAL TMGB DRILLED HOLE DIMENSIONS

COMPRESSION

CONNECTOR W/

VIEWING WINDOW

1 1/2" NOMINAL

INSULATOR

STAINLESS STEEL

STANDOFF BRACKET

ELECTRO-TIN PLATED

COPPER GROUND BAR

STAINLESS STEEL HARDWARE

TYPE

TMGB 20"

WIDTH

4"

THICKNESS

1/4" 24 3

MINIMUM

LENGTH

MINIMUM NUMBER OF

PAIRS OF 5/16"

DIAMETER HOLES

MINIMUM NUMBER OF

PAIRS OF 7/16"

DIAMETER HOLES

TELECOMMUNICATIONS MAIN GROUND BAR (TMGB) &

TELECOMMUNICATIONS GROUND BAR (TGB) SCHEDULE ANSI-J-STD-A-2002

2"

1 1/8" TYP

5/16" DIAMETER HOLE PAIR (TYP)

7/16" DIAMETER HOLE PAIR (TYP)

5/8".

5/8".

1".

FINISHED CEILING

(WHERE SCHEDULED)

FINISHED FLOOR

SECURED

ACCESS DOOR

TO NEXT

DOOR

1 2 3 4 6

A

B

C

D

SHEET OF

SHEET ID

P a rk w a y L a n e S u it e

P e a c h tr e e

C o rn e rs

G

A

P h o n e

-7

F a x

-7

S

IZ

E

A

N S

I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

A N

G N

O

C O

N T

R A

C T

N O

F

IL

E N

U N

B E

R

A P

P R

D

E S

C R

IP

T

IO

N

M A

R K

E

D A

T E

S B

R

Professional Certification.

I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No.

Expiration Date:

/2 /2

:2

:5

P M

C R e v it L o c a l\

\1

D C

A N

G

M L C

T F

H

A N

G A

R

E L E

C

C E

N T

R A

L

R m a p

.r v t

T-501

TYPE B-3 (100%) SUBMITTAL - ISSUED FOR BID

T E

L E

C O

M D

E T

A

IL

S

M U

N

IT

IO

N

S L

O A

D C

R E

W T

R A

IN

IN

G F

A C

IL

IT

Y th

W

IN

G D

C A

N G

J O

IN

T

B A

S E

A N

D R

E W

S ,M

D

D

IS

T R

IC

T

O F

C O

L U

M B

IA

A

IR

N

A T

IO

N

A L

G U

A R

D

J O

B N

O

M A

P

M A

P

J M

S

O

C T

O B

E R

A J X

F

W

L

-1 -D

-0

X X

-X -X

X X

X

SCALE: N.T.S.D4

TYPICAL COMMUNICATIONS OUTLET DETAIL

SCALE: N.T.S.D3

WALL MOUNT COMMUNICATIONS OUTLET DETAIL

SCALE: N.T.S.C1

TELECOMMUNICATIONS MAIN GROUND BAR

SCALE: N.T.S.A4

SECURITY DETAIL - SINGLE DOOR

3/4"C TO SECURITY PANEL.

PROVIDE ROUGH IN FOR BALANCED MAGNETIC SWITCH.

PROVIDE ROUGH IN FOR ACCESS CONTROL PANEL.

PROVIDE ROUGH IN FOR CARD READER.

3/4"C TYPICAL

PROVIDE ROUGH IN FOR ELECTRIC LOCKSET. POWER FROM SECURITY PANEL.

KEY NOTES:

50902 05/11/19

PET

TMGB

CEILING

PLYWOOD

BACKBOARD

PLYWOOD

BACKBOARD

TO BUILDING 3029

COMM ROOM

TO STUBUP

BEHIND BUILDING 3032

HANGAR BAY

TO FIRE PUMP

HOUSE

1 2 3 4 6

A

B

C

D

SHEET OF

SHEET ID

P a rk w a y L a n e S u it e

P e a c h tr e e

C o rn e rs

G

A

P h o n e

-7

F a x

-7

S

IZ

E

A

N S

I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

A N

G N

O

C O

N T

R A

C T

N O

F

IL

E N

U N

B E

R

A P

P R

D

E S

C R

IP

T

IO

N

M A

R K

E

D A

T E

S B

R

Professional Certification.

I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No.

Expiration Date:

/2 /2

:2

:5

P M

C R e v it L o c a l\

\1

D C

A N

G

M L C

T F

H

A N

G A

R

E L E

C

C E

N T

R A

L

R m a p

.r v t

T-601

TYPE B-3 (100%) SUBMITTAL - ISSUED FOR BID

T E

L E

C O

M R

IS

E

R D

IA

G

R A

M

M U

N

IT

IO

N

S L

O A

D C

R E

W T

R A

IN

IN

G F

A C

IL

IT

Y th

W

IN

G D

C A

N G

J O

IN

T

B A

S E

A N

D R

E W

S ,M

D

D

IS

T R

IC

T

O F

C O

L U

M B

IA

A

IR

N

A T

IO

N

A L

G U

A R

D

J O

B N

O

M A

P

M A

P

J M

S

O

C T

O B

E R

A J X

F

W

L

-1 -D

-0

X X

-X -X

X X

X

SCALE: N.T.S.C1

TELECOMMUNICATION RISER DIAGRM

PROVIDE NEW 12 STRAND SINGLE MODE AND 12 STRAND MULTI MODE

FIBER OPTIC CABLE FROM EXISTING BUILDING 3029 TO COMM ROOM.

50 PAIR COPPER FROM STUB UP BEHIND FORMER BUILDING 3032.

#4 INSULATED COPPER GROUND.

#4 BARE COPPER GROUND BONDED TO BUILDING GROUND BAR.

NEW FIBER EQUIPMENT RACK.

NEW VOICE/DATA EQUIPMENT RACK.

50 PAIR 110 TYPE WIRING BLOCKS EQUIPPED WITH WALL MOUNTING

STANDOFF LEGS.

VERTICAL CABLE MANAGEMENT.

HORIZONTAL CABLE MANAGEMENT.

FIBER OPTIC PATCH PANEL

48 PORT VOICE/DATA PATCH PANEL

1/4" THICK X 20"L X 4"W TELECOMMUNICATIONS MAIN GROUND BAR. SEE

DETAIL C1/T-501.

KEY NOTES:

1 PROVIDE 3/4"C TO CABLE TRAY.

FIBER OPTIC CONCENTRATOR

COMMUNICATIONS OUTLET (4 DATA CATEGORY 6A, RJ-45 JACK). SEE DETAIL

D4/T-501.

COMMUNICATIONS PULL BOX. MOUNT TO BUILDING EXTERIOR FOR TRANSITION

TO/FROM UNDERGROUND DUCTBANK.

12"W X 4"H LADDER STYLE CABLE TRAY. PROVIDE RUNG SPACING NO GREATER

THAN 9".

TWO 2 x 4" DUCTBANK FOR COPPER AND FIBER OPTIC SERVICE TO THE

BUILDING. SEE ES-101 FOR CONTINUATION.

BASKET TYPE CABLE TRAY, MOUNT ABOVE SUSPENDED CEILING.

REFER TO DETAIL C3/E-401 FOR RECEPTACLES MOUNTED ON CABLE TRAY.

25 PAIR COPPER TO FIRE PUMP HOUSE. SEE ES-101 FOR CONTINUATION.

15 15

11TYP 10

9TYP

8 TYP

15 15

13 13

20 20

50902 05/11/19

Porpoise_4606
Porpoise_4607
Porpoise_4608
Porpoise_4609
Porpoise_4610
Porpoise_4611
Porpoise_4612
Porpoise_4613
Porpoise_4614
Porpoise_4615
Porpoise_4616
Porpoise_4617
Porpoise_4618
Porpoise_4619
Porpoise_4620
Porpoise_4621
Porpoise_4622
Porpoise_4623
Porpoise_4624
Porpoise_4625
Porpoise_4626
Porpoise_4627
Porpoise_4628
Porpoise_4629
Porpoise_4630
Porpoise_4631
Porpoise_4632
Porpoise_4633
Porpoise_4634
Porpoise_4635
Porpoise_4636
Porpoise_4637
Porpoise_4638
Porpoise_4639
Porpoise_4640
A801
I401
Porpoise_4646
Porpoise_4647

File details come from the government source that posted it.