Building 3-1947 Asbestos Report.pdf
PDF 1 MB Posted
- Attached to
- SC-00008-20 Renovate Building 3-1947
- Solicitation number
- W912PM22B0013
About this file
This document contains an asbestos survey report and a federal contract opportunity solicitation. The asbestos survey report documents an inspection of Building 3-1947 at Fort Bragg, North Carolina, which identified asbestos-containing gray floor tile with black mastic estimated at 15,345 square feet.
The federal contract opportunity is a firm-fixed-price solicitation from the U.S. Army Corps of Engineers, Wilmington District to renovate Building 3-1947 at Fort Bragg into administrative workspaces. The renovation includes classified telecommunications cabling. The existing 21,401 square foot building previously housed another unit that relocated. The solicitation is 100% set aside for competitive small businesses. The NAICS code is 236220 and size standard is $39.5 million. The magnitude of construction is estimated between $5-10 million. The solicitation will be issued electronically through the System for Award Management, and interested parties must register at SAM.gov. The point of contact is the Contracting Officer, Karri Mares.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(Photo Not Available Due to National Security)
Signature
Solomon Locklear, Carolina Environmental Design, LLC NC License # 12601
Asbestos Survey for Renovation of
Building 3-1947 Fort Bragg, North Carolina
Prepared by Solomon Locklear, Carolina Environmental Design, LLC for the
Directorate of Public Works, Ft .Bragg, North Carolina
Table of Contents
Asbestos Inspection Report………………………………………………………...1
List of Tables
Table 1 Asbestos Table
Table 2 Carolina Environmental Inc. Analytical Report…………………..…….7
Table 3 Asbestos Samples Chain of Custody Forms
Appendices
Appendix A. Certifications and Accreditations…………………. ......... ………13
Asbestos Inspection Report
Introduction
Scope of the Investigation
This report documents the asbestos inspection and survey of Building 3-1947 at Ft. Bragg, North Carolina conducted on 03/04/2013.
Background
Building 3-1947 is a two story structure that is used by JSOC and the building is used specifically for office space. Due to national security concerns, the asbestos inspector was not allowed in the office areas of Building 3-1947. Most of the samples collected were collected from the hallways, mechanical rooms, electrical closets, janitorial closets and latrines. The outside of the building is constructed out of concrete. The windows of the building are constructed out of aluminum, held in place with rubber/silicone caulking. The roof is constructed from the top down with concrete surfaced expandable polystyrene foam insulation over single ply membrane over several inches of foam insulation over a metal roof deck. The inside walls are constructed out of both CMU (block) and drywall/joint compound. The ceilings of the building have drywall/joint compound that is covered with white 2’x2’ drop ceiling. The flooring system is constructed out of concrete. It appears that the 12”x12” floor tile is present in the hallways and offices. Green carpet is covering some of the 12”x12” floor tile in the hallway and offices. When looking under the assessing some of the offices with carpet, it appeared that some of the floor tile had been removed in some of the offices. Due to not being able to assess all of the offices, it was not able to be determined if floor tile was present in each and every office.
There is a mechanical room present on the outside of the building as well as on each floor. The pipes and elbows running throughout the mechanical room and building are covered with white yellow fiberglass material, covered with a white thermal insulation wrap.
Description of study
Investigation
Areas of Building 3-1947 were visually inspected for suspected asbestos containing materials (ACM) by North Carolina accredited inspectors. A copy of the inspector’s accreditation certificate is included in Appendix A. Bulk samples of all suspect ACM’s were collected. This report details ACM as identified at the time of inspection only. Please be advised that if the building in to undergo demolition or renovation, additional sampling maybe required for hidden materials that were not accessible of sampling when the initial asbestos inspection was done. A focused inspection was conducted for the presence of asbestos containing building materials (ACBM). Laboratory results indicated that ASBESTOS WAS DETECTED. These results pertain only to that portion of the building for which renovation (work) actions are proposed and is not applicable to the remaining spaces in the building.
Carolina Environmental Inc. analyzed the bulk samples. The laboratory is accredited by the
National Voluntary Laboratory Accredited Program (NVLAP Accreditation sponsored by the
National Institute of Standards and Technology (NIST)). A Copy of their accreditation certificate is included in Appendix A. The samples were analyzed by the accepted method of polarized light microscopy (PLM) using EPA’s “Method For the Determination of Asbestos In Bulk Building
Materials”, EPA/600/R-93/116. The laboratories’ analytical report is included in Appendix A.
In compliance with the AHERA regulations, material is considered an Asbestos Containing
Material (ACM) when it contains greater than one percent asbestos. Likewise, in this report, any material containing concentrations greater than one percent asbestos will be considered
“positive”. Occasionally, materials containing less than one percent asbestos, or not sampled, are assumed to be a “positive” asbestos containing material at the discretion of the inspectors. A narrative discussion of the AHERA ACM types (i.e., thermal systems insulation, miscellaneous and surfacing materials) found in Building No. 3-1947 is included in this report where relevant.
Bulk sample information, estimated quantities of individual asbestos containing materials, and material characterization of asbestos containing materials appears on Table 1. The approximate location where each bulk sample was obtained is shown on the building floor plans, Figure 1.
Conclusions
ASBESTOS-CONTAINING MATERIAL DETECTED.
Thermal System Insulation
TSI is insulation material applied to pipes, fittings, tanks, ducts, or on other interior structural components to prevent heat loss or gain, or water condensation, or for other purposes.
There was not any asbestos containing TSI materials detected in Building 3-1947.
Miscellaneous Materials
Miscellaneous materials include building material on structural components, structural members or fixtures, such as floor and ceiling tiles, and do not include surfacing or TSI. The following suspect miscellaneous materials at Building 3-1947 were found to contain asbestos at the time of sampling: Black Mastic Covered with Gray/ Off White 12”x12 Floor Tile
Surfacing
Surfacing material is friable material that is sprayed on, troweled on, or otherwise applied to surfaces for decorative or other purposes. No surfacing material was found to contain asbestos located in Building 3-1947 at the time of sampling.
TABLE 1
ASBESTOS TABLE
FORT BRAGG, BUILDING 3-1947
Date of Inspection: March 4 th , 2013
Inspector: Solomon Locklear
Inspector Certification Number: NC Number 12601
MATERIAL CHARACTERISTICS ASSESSMENT
Type Description/Location % Asbestos
Yes/No/Presumed
Quantity/Type
(If ACM)
Friable /
Non-
Friable
Condition Disturbance
Potential
MISCELLANEOUS
12”x12” Gray/Off-White
Floor Tile With Black
Mastic, Some Covered
With Green Carpet
Present in Offices and
Hallways on Both Floors
Asbestos Detected
5%
Chrysotile
Estimated 15,345
Non-
Friable Good
MISCELLANEOUS Drywall/Joint Compound None Detected
MISCELLANEOUS 2’x2’ White Drop Ceiling None Detected
TSI Pipe Insulation None Detected
Sq. Ft.-Square Foot, Ln. Ft.-Linear Foot, C. Ft.-cubic Foot
Materials Containing Asbestos are in Bold Print.
Table 2
Table 3 Chain of Custody
Appendix A
File details come from the government source that posted it. Updated .