Misc_Drawings_Part5.pdf

PDF 10 MB Posted

Attached to
Amend 0003 Federal contract opportunity
Solicitation number
W912P815B0046
Issued by
Department of the Army Corps of Engineers Engineering District New Orleans

About this file

Drawings Misc

View the file

Other files for this federal contract opportunity

Other files attached to Amend 0003, newest first.
File Type Posted
Drawing_for_MA-1_(_11-12-04)_New_Foundation_Part5.pdf PDF
Drawing_for_MA-1_(_11-12-04)_New_Foundation_Part10.pdf PDF
Drawing_for_MA-1_(_11-12-04)_New_Foundation_Part2.pdf PDF
Technical_Data_(ALFA_LAVAL)_Plate_Heat_Exchanger_AX30-HBM.pdf PDF
Bid_Bond_Form_SF_24-98.pdf PDF
Drawing_for_MA-1_(_11-12-04)_New_Foundation_Part6.pdf PDF
Drawing_for_MA-1_(_11-12-04)_New_Foundation_Part7.pdf PDF
Drawings_11-04-01_opt.pdf PDF
Drawings_Launch_Edge_Water_914-433-000_General_Arrangement.pdf PDF
Drawings_Launch_Edge_Water__914-433-011_Davit_Arm_Installation _Winch_and_Misc_Details.pdf PDF
Drawings_Launch_Edge_Water__914-433-003_Support_Frame_Weldment.pdf PDF
Drawings_Launch_Edge_Water__914-433-004_Pin_ _Lock_Plate.pdf PDF
Drawings_Launch_Edge_Water_914-433-001_Calculation_Dwg.pdf PDF
Drawings_11-03-04_(Transv_Floor_Frs_114-149).PDF PDF
Drawings_Launch_Edge_Water__914-433-002_Davit_Arm_Weldment_Details.pdf PDF
Drawings_LAFCO_441-4_Mid_Ship_Sections.pdf PDF
Drawings_LAFCO_441-10_Steering_Sys.PDF PDF
Drawings_70006-4013-902_(Rev_F).PDF PDF
Amemd_0001_SF30.pdf PDF
Avondale_Drawings_combined_Part70.pdf PDF
Avondale_Drawings_combined_Part49.pdf PDF
Avondale_Drawings_combined_Part4.pdf PDF
Avondale_Drawings_combined_Part58.pdf PDF
Avondale_Drawings_combined_Part17.pdf PDF
Avondale_Drawings_combined_Part5.pdf PDF
Avondale_Drawings_combined_Part27.pdf PDF
Avondale_Drawings_combined_Part56.pdf PDF
Avondale_Drawings_combined_Part61.pdf PDF
Avondale_Drawings_combined_Part74.pdf PDF
Avondale_Drawings_combined_Part8.pdf PDF
Avondale_Drawings_combined_Part23.pdf PDF
Avondale_Drawings_combined_Part75.pdf PDF
Avondale_Drawings_combined_Part45.pdf PDF
Avondale_Drawings_combined_Part24.pdf PDF
Avondale_Drawings_combined_Part55.pdf PDF
Avondale_Drawings_combined_Part18.pdf PDF
Avondale_Drawings_combined_Part28.pdf PDF
Avondale_Drawings_combined_Part44.pdf PDF
Avondale_Drawings_combined_Part50.pdf PDF
Avondale_Drawings_combined_Part60.pdf PDF
Avondale_Drawings_combined_Part25.pdf PDF
Avondale_Drawings_combined_Part34.pdf PDF
Avondale_Drawings_combined_Part39.pdf PDF
Misc_Drawings_Part4.pdf PDF
Misc_Drawings_Part3.pdf PDF
Dredge_Technology_Drawings_Part8.pdf PDF
Dredge_Technology_Drawings_Part4.pdf PDF
Section_J_Attachment_List_.pdf PDF
W912P8-15-B-0046.pdf PDF
Section_J_Attachment_List_.pdf PDF
Show all 50

Amend 0003 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HPU Item #20.1 Hydraulic Power Unit - Item #20.1 - WV-34Hydraulic Power Unit - Item #20.1 - WV-34

8-888-88

Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH

Foam Pads Isolates the removal materials from contact with heavy reservoir mist and securely holds materials in place.

Filter Pads Specially designed filter pads remove solid particulate on upstream side and then regenerate by releas-ing those particles when air flow reverses direction. Lower pad removes airborne contamination and second pad protects against any migration of desiccant.

Air Intakes A total of eight air intakes may be exposed to allow air to freely flow in and out of the TriCeptor.

Breathers Desiccant Type

Specifications:

Materials:

Casing: Clarified copolymer polypropylene.

Cap: Copolymer polypropylene.

Stand pipe: PVC.

Filtration Element: Polyester, silica gel.

Operating Temperatures: -20oF (-29oC) to 250oF (121oC).

Seals: None.

Maximum Allowable Operating Pressure (MAOP): 5 psi (.34 bar).

Particle Removal Efficiency:

98.7% (beta 75) @ 3 micron 99.5% (beta 200) @ 4 micron 99.9% (beta 1000) @ 5.3 micron Weight:

934330T 1.25 lbs. (.57 kg) each.

934331T 1.75 lbs. (.79 kg) each.

934332T 2.25 lbs. (1.02 kg) each.

Silica Gel Desiccant Has the highest removal capability by volume of any adsorption method. Indicates condition by changing color.

Foam pad Insures filter pad is properly positioned and protects it from external damage.

Molded Housing Durable shock absorbing casing provides reliable service and simple press in mounting.

Features

Reservoir Accessories Breathers

HPU Item #22 Hydraulic Power Unit - Item #22 - 934330THydraulic Power Unit - Item #22 - 934330T

8-898-89

Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH

0 4 8 12 16 20

P

SI

D B A

R

2.5

2.0

1.5

1.0

.5

3.0

SCFM

Liters/Second

0 1.88 3.78 5.66 7.55 9.44

3.5 .241

.207

.172

.138

.103

.068

.034

0 30 60 90 120 150

PS

ID

B

AR

2.5

2.0

1.5

1.0

.5

3.0

3.5 .241

.207

.172

.138

.103

.068

.034

GPM (fluid exchange rate)

41.66

33.53 1.32

101. 6

127.0

9.0

98.55 3.88

1.64

4. 0

5.0

178.0 7.0

229.0

1“ NPT

Thread

Installation

TriCeptor breathers are designed for simple installation on most equipment, regardless of mounting connection.

Since TriCeptor breathers are disposable, the threaded connection allows for quick and easy maintenance. Several mounting adapters (shown below) are available to provide the desired mounting. The installation/replacement pro-cess consists of four easy steps:

1. Remove from protective plastic wrap.

2. Remove 1" blue cap from standpipe.

3. Remove foil label to expose the necessary amount of air intake holes.

4. Twist TriCeptor into mounting adapter.

Servicing the TriCeptor breather is also very easy. When the silica gel changes color from blue to a pink, the breather is no longer active and needs to be replaced.

Simply remove the unit and discard properly.

Air Flow Performance

The curves below show the air flow performance of the three TriCeptor breathers. To insure the longest life possible, the initial clean pressure drop should not exceed 1.5 psid (.103 bar).

Field Adapter Flange Adapter

Part Number

934330T

934331T

934332T

937546

937463

Model

5" Breather

7" Breather

9" Breather

Field Adapter

Flange Adapter

Reservoir Accessories Breathers

Quantity

6 pcs.

6 pcs.

6 pcs.

1 pc.

1 pc.

Linear Measurement= mm in

HPU Item #22 Hydraulic Power Unit - Item #22 - 934330THydraulic Power Unit - Item #22 - 934330T

8-908-90

WITH AND WITHOUT

THERM OMETER

STANDARD MATERIALS:

! Aluminum construction

! Buna N seals

! Borosilicate glass with redline on white background for distinct level reading and maximum fluid compatibility

OPERATING CONDITIONS:

! See ENG. STD. 109

EXAMPLE: G615-05-A-1

Buna N seals

Aluminum gage body

5.00 (127.00mm) Centers

SERIES G615

HOW TO ORDER:

Use code letters for body material: Use code number for seal material:

A - Aluminum gage body (standard) 1 - Buna N seals (standard) B - Brass gage body (optional) 2 - Butyl seals (optional) S - Steel gage body(optional) 3 - Viton A® seals (optional) Y - Stainless Steel gage body 4 - Ethylene propylene seals (optional)

(optional) 10- Neoprene seals (optional) First, specify series number, then mounting centers, then kind of metal, and finally seal material, separating each with a dash (-):

SERIES

G605

WITHOUT

THERM.

SERIES

G615

WITH

THERM.

A - CENTERS

INCHES

(mm)

B - SIGHT

INCHES

(mm)

C - LENGTH

INCHES

(mm)

G605 G615 03 (76.20) 1.50 (38.10) 4.62 (117.35)

G605 G615 04 (101.60) 2.50 (63.50) 5.62 (142.75)

G605 G615 05 (127.00) 3.50 (88.90) 6.62 (168.15)

G605 G615 06 (152.40) 4.50 (114.30) 7.62 (193.55)

G605 G615 07 (177.80) 5.50 (139.70) 8.62 (218.95)

G605 G615 08 (203.20) 6.50 (165.10) 9.62 (244.35)

G605 G615 09 (228.60) 7.50 (190.50) 10.62 (269.75)

G605 G615 10 (254.00) 8.50 (215.90) 11.62 (295.15)

G605 G615 11 (279.40) 9.50 (241.30) 12.62 (320.55)

G605 G615 12 (304.80) 10.50 (266.70) 13.62 (345.95)

A patented dual purpose closed circuit style liquid level gage that provides both instant and positive visual check of fluid levels and temperature in either hydraulic or oil reservoirs. Maximum sight protection is provided by the heavy precision machined bar stock body. Thermometer series gages have a protected sensing element that extends well into the tank -unaffected by unrelated ambient temperature. Gages are furnished complete including O-ring seals and hex nuts for mounting. A .06 (1.52mm) alignment adjustment at each stud facilitates mounting. This gage can be installed from the outside on 1/2-20UNF tapped holes when reservoirs do not have access to the interior and tank wall thickness permits tapping. For installations where gage is bolted to cylindrical tank wall, conical sleeves are available. Please specify when ordering. Front mounting gages can be made to order with mounting centers up to 142.00 (3606.80mm) in 1.00 (25.40mm) increments. Stainless steel dial thermometer: 1.38 (35.05mm) dia. dual scale Fahrenheit (50° to 300°), Centigrade (10° to

150°). For back mount gages see our SERIES G610 and G620 on Bulletin F327-10/-20.

Lube Devices ! Flodar ! Hydra-Tool ! Vescor

1864 Nagle Ave. P. O. Box 1810

Manitowoc, WI 54221-1810

Phone: (920) 682-6877 Fax: (920) 684-7210

E-MAIL: sales@ldi-industries.com WEBSITE: www.ldi-industries.com

NOTE: The sight opening in all cases is 1.50

(38.10mm) less than mounting centers and overall length is 1.62 (41.15mm) greater than mounting centers. Gages with 13.00 (330.20mm) and greater mounting centers are furnished with spacer sleeves to space gage from tank allowing for bowing of the tank wall in larger reservoirs. Center mounting kits are furnished with gages 48.00 (1219.20mm) and greater mounting centers.

SERIES G605 - SIGHT ONLY

SERIES G615

WITH DIAL THERMOMETER

FRONT MOUNTING LIQUID LEVEL GAGES -

WITH AND WITHOUT THERMOMETER

7/06 BULLETIN F327-5 / -15

ISO9001:2000 CERTIFIED

FRONT MOUNTING LIQUID LEVEL GAGES -

HPU Item #23

Hydraulic Power Unit - Item #23 - G615-10-A-1Hydraulic Power Unit - Item #23 - G615-10-A-1

8-918-91

*By-Pass not available on this model

Ordering Information To Specify By-Pass Option Add -RV3 to Part Number

Features

• Stainless steel mesh

• Re-usable

• Epoxy bonded joints for compatibility with all fluids

• Rugged steel inner support

• Plated end caps

• 100 & 200 mesh from stock

Options

• No by-pass or 3 psi by-pass available (RV3)

• Custom sizes and mesh are available upon request

Ordering Information To Specify By-Pass Option Add -RV3 to Part Number

*By-Pass not available on this model

Series SS (Steel)

Vescor Dimensions Part Nominal Flow Port Filter Area A B Mesh Micron

Number GPM L/min. (NPT) in. cm in. mm in. mm

SS-3* 3 11 3/8” 34 220 2.50 64 1.90 48 100 140

SS-5 5 19 1/2” 62 400 3.10 78 2.70 67 100 140

SS-8 8 31 3/4” 62 400 3.50 89 2.70 67 100 140

SS-10 10 38 1” 110 710 5.40 136 2.70 67 100 140

SS-20 20 88 11/4” 162 1050 6.90 174 3.40 86 100 140

SS-30 30 120 11/2” 225 1450 8.10 204 3.40 86 100 140

SS-50 50 198 11/2” 340 2190 10.00 225 4.00 100 100 140

SS-51 50 198 2” 340 2190 10.00 225 4.00 100 100 140

SS-75 75 283 21/2” 400 2580 10.10 257 5.20 130 100 140

SS-100 100 379 3” 500 3230 11.80 298 5.20 130 100 140

Vescor Dimensions Part Nominal Flow Port Filter Area A B Mesh Micron

Number GPM L/min. (NPT) in. cm in. mm in. mm

SS-3-2M* 3 11 3/8” 20 220 2.50 64 1.90 48 200 74

SS-5-2M 5 19 1/2” 62 400 3.10 78 2.70 67 200 74

SS-8-2M 8 31 3/4” 62 400 3.50 89 2.70 67 200 74

SS-10-2M 10 38 1” 110 710 5.40 136 2.70 67 200 74

SS-20-2M 20 88 11/4” 162 1050 6.90 174 3.40 86 200 74

SS-30-2M 30 120 11/2” 225 1450 8.10 204 3.40 86 200 74

SS-50-2M 50 198 11/2” 340 2190 10.00 225 4.00 100 200 74

SS-51-2M 50 198 2” 340 2190 10.00 225 4.00 100 200 74

SS-75-2M 75 283 21/2” 400 2580 10.10 257 5.20 130 200 74

SS-100-2M 100 379 3” 500 3230 11.80 298 5.20 130 200 74

VC SUCTION STRAINERS

NOTE: WITH VESCORS' POLICY OF CONSTANTLY IMPROVING ITS PRODUCTS, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.156

1 APR 02

HPU Item #24Hydraulic Power Unit - Item #24 - SS-51Hydraulic Power Unit - Item #24 - SS-51

8-928-92

14a

PHONE: 937/277-9364 FAX: 937/277-6516 www.lenzinc.com

FI

LT

ER

S

S

TR

AI

NE

RS

Sump Strainers N49 / 49 Series

Plated Steel Hex or Nylon Hex Pipe Nut Coupling:

In a full range of NPT sizes, 3/4" thru 3". Welded on.

Plated Steel End Cap or Nylon Epoxy-bonded for one-piece construction.

Steel Back-Up Cylinder:

Provides rigidity, permits easy cleaning and better flow.

Pleated, Reusable Stainless Wire Cloth:

Keeps its shape and allows better flow. For use with hydraulic fluids, oils, coolants, cutting oils and lubricants.

Excellent for mobile equipment. Easily cleaned. Choice of 30, 60, 100 or 200 mesh. See table.

Plated Steel Cap End:

Epoxy-bonded for one-piece construction.

Trouble-Free Positive Protection:

All metal, nickel plated construction. No organic elements to deteriorate. These smooth, one-piece, epoxy-bonded units are carefully and compactly constructed with quality materials throughout. They assure trouble-free, positive protection for the entire system. Excellent for mobile equipment.

Easily Installed and Cleaned:

Easily removed and cleaned with gasoline and similar solvents.

OPTIONAL:

Nylon hex pipe nut coupling, one piece.OPTIONAL

Built-in relief valve to prevent pump starvation / Part No. R3 & R5

3 & 5 PSI relief valve is optional extra.

To specify add to Model No.

Example: 49-50-R3-100

MESH

CENTER DIA. OF WIDTH OF WIDTH OF PERCENT

AGE WIRE OPENING OPENING OF

TO (Inches) (Inches) (Microns) OPEN AREA

CENTER

30 .011" .022" 557 44.8 60 .0065" .010" 253 37.5 100 .0045" .0055" 140 30.3 200 .0021" .0029" 74 33.6

Stainless Wire Cloth • Stock Meshes

N49-SERIES 49-SERIES

Steel Hex

Nylon Hex Nut (One Piece)

PART NUMBER

G.P.M. A B C D

AREA

NYLON STEEL (CM2)

N49-3 49-3 3

IN 3/8" 1.2 2.5 1.9 34

MM . 30.4 63.5 48.3 (219.3)

N49-4 49-4 5

IN 1/2" 1.9 3.1 2.6 62

MM 48.2 78.7 66 (399.9)

N49-5 49-5 8

IN 3/4" 2.9 3.6 2.6 62

MM 73.7 91.4 66 (399.9)

N49-10 49-10 10

IN 1" 4.6 5.4 2.6 110

MM 116.8 137.2 66 709.5)

N49-20 49-20 20

IN 11/4" 6.1 6.9 3 162

MM 154.9 175.3 76.2 (1044.9)

N49-30 49-30 30

IN 11/2" 7.2 8 3.3 225

MM 182.9 203.2 83.8 (1451.3

N49-50 49-50 50

IN 11/2" 9.1 9.9 3.9 340

MM 231.1 251.5 99.1 (2193)

N49-50-2 49-50-2 50

IN 2" 9.1 9.9 3.9 340

MM 231.1 251.5 99.1 (2193)

N49-75 49-75 75

IN 21/2" 9.1 10.1 5.1 400

MM 231.1 256.5 129.5 (2580)

N49-100 49-100 100

IN 3" 10.4 11.8 5.1 500

MM 264.2 299.7 129.5 (3225)

FLOW RATE (GPM)

PR

ES

SU

RE

D

RO

P (B

AR

38 76 114 151 189 227 265 303 341 379/ 416 454

10 20 30 40 50 60 70 80 90 100 110 120

FLOW RATE (LPM)

1.0

.8

.6

.4

.2

PR

ES

SU

RE

D

RO

P (p si

.07

.08

.06

.04

.02

GP

M

/8

GP

M

/2

GP

M 3 /

4"

G

PM

G

PM

1 /4

G

PM

1 /2

G

PM

1 /2"

G

PM

75 GPM 21 /2"

100 GPM 3"

49/N49 Series

TO ORDER OTHER THAN 100 MESH ADD -30, 60, 200

TO SPECIFY BY-PASS OPTION, ADD R3 & R5

Dimensions

HPU Item #25

Hydraulic Power Unit - Item #25 - 49-5-100Hydraulic Power Unit - Item #25 - 49-5-100

8-938-93

Model: AEJ

T-162A cavity line mount manifold

Aluminum Body Pressure Rating: 3000 psi (210 bar) Ductile Iron Body Pressure Rating: 5000 psi (350 bar)

Technical Data

U.S. Units Metric Units

Cavity T-162A

Body Features Through port 1 with gauge port

Body Type Line mount

Interface None

Open Cavity Quantity 1

Mounting Hole Thread .250-20 UNC - 2B in.

Mounting Hole Depth .50 in. 12,7 mm

Mounting Hole Quantity 2

Display Components

Part Description Quantity

AEJ Body - Aluminum 1

Port Headings and Sizes

AEJ Ports 1 & 2 SAE 8

AEJ Gage Port 1/4" NPTF http://www.sunhydraulics.com Date Created: 11/4/2011

Copyright © 2010-2011 Sun Hydraulics Corporation. All rights reserved.

HPU Item #26.1 Hydraulic Power Unit - Item #26.1 - AEJHydraulic Power Unit - Item #26.1 - AEJ

8-948-94

Catalog HY14-2502/US

2502-F9.p65, dd

F28 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA

Check Valves

H

F

General Description

Series “C” check valves permit free flow in one direc-tion, and dependable shut-off in the reverse direction.

Operation

When pressure going through the valve is increased to the cracking level, the valve opens. When the pressure is reduced to below the cracking level, the valve closes.

Features

• Stainless steel poppets standard.

• Soft seal poppets are available.

• Triangular retainers guide the poppets, and hold the spring firmly in place even under high velocity and shock.

Specifications

Technical Information

Maximum Brass: 140 Bar (2000 PSI);

Operating except for C1600 brass Pressure which is 35 Bar

(500 PSI)

Steel & 345 Bar (5000 PSI) for Stainless 200 thru 1220;

Steel: 207 Bar (3000 PSI) for all other sizes and styles

Maximum Flow C200: 11 LPM (3 GPM)

C400: 19 LPM (5 GPM)

C600: 30 LPM (8 GPM)

C620: 19 LPM (5 GPM)

C800: 57 LPM (15 GPM)

C820: 30 LPM (8 GPM)

C1020: 57 LPM (15 GPM)

C1200: 95 LPM (25 GPM)

C1220: 95 LPM (25 GPM)

C1600: 151 LPM (40 GPM)

C1620: 151 LPM (40 GPM)

C2000: 265 LPM (70 GPM)

C2020: 265 LPM (70 GPM)

C2400: 379 LPM (100 GPM)

C2420: 379 LPM (100 GPM)

C3200: 569 LPM (150 GPM)

C3220: 569 LPM (150 GPM)

Poppets Soft seal poppet is standard for 200 through 800/1020 size.

For cracking pressures > 15 PSI, solid metal poppets are standard

Series C

Performance Curves

Controlled Flow vs. Pressure Drop Free Flow 0.3 Bar (5 PSI) Cracking

100 SSU, Hydraulic Oil

283.9 378.5 473.1189.3

75 100 12550

567.8

94.6

Flow

P re ss ur e D ro p

LPM

GPM

25 1.7

50 3.5

75 5.2

8.6

10.5

6.9

PSI

12.1

14.0 Bar 200

400, 600, 800, 1200, 1600, 2020, 2420, 3220, HPU Item #29 Hydraulic Power Unit - Item #29 - C820SHydraulic Power Unit - Item #29 - C820S

8-958-95

Check ValvesCatalog HY14-2502/US

2502-F9.p65, dd

F29 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA

F

Technical Information Series C

Code Description

Omit Nitrile (Standard)

V Fluorocarbon

Code Description

Omit Standard

0.4 Bar (5 PSI)

65 4.5 Bar (65 PSI)

Other cracking pressures available

Code Description

B Brass

S Steel

SS * Stainless Steel Series C Brass Valves can be used for both air and oil service.

* Available in 400, 600 and 800 sizes.

200 * 800*† 1600 * 2400 400 *† 820 1620 2420 600 *† 1020 2000 3200 620 1200 * 2020 3220

* Sizes available in Brass † Sizes available in Stainless Steel

Ordering Information

Code Description

Omit NPTF/SAE

8 BSPT

9 BSPP

Model Weight Number kg (lbs.)

C200 0.0 (0.1) C400 0.2 (0.4) C600 0.2 (0.5) C620 0.2 (0.5) C800 0.6 (1.3)

C820 0.3 (0.7) C1020 0.6 (1.3) C1200 0.9 (2.0) C1220 0.9 (2.0)

Model Weight Number kg (lbs.)

C1600 1.5 (3.3) C1620 1.5 (3.3) C2000 2.8 (6.2) C2020 2.8 (6.2)

C2400 3.8 (8.4) C2420 3.8 (8.4) C3200 7.0 (15.4) C3220 7.0 (15.4)

Model Weight Number kg (lbs.)

Model Weight Number kg (lbs.)

Design Series

NOTE:

Not required when ordering.

Options Series C Size Material Cracking Pressure (nominal)

Seal Compound

C

Model Number A B C D

C200 1/8– 27 NPTF 50.8 (2.00) 16.0 (0.63) 7.9. (0.31)

C400 1/4– 18 NPTF 66.8 (2.63) 20.6 (0.81) 10.4 (0.41)

C420 7/16– 20 UNF #4 SAE 68.3 (2.69) 20.6 (0.81) 10.4 (0.41)

C600 3/8– 18 NPTF 69.9 (2.75) 25.4 (1.00) 12.7 (0.50)

C620 9/16– 18 UNF #6 SAE 79.2 (3.12) 25.4 (1.00) 12.7 (0.50)

C800 1/2– 14 NPTF 87.4 (3.44) 31.8 (1.25) 16.0 (0.63)

C820 3/4– 16 UNF #8 SAE 88.9 (3.50) 28.4 (1.12) 14.2 (0.56)

C1020 7/8– 14 UNF #10 SAE 101.6 (4.00) 31.8 (1.25) 15.7 (0.62)

C1200 3/4– 14 NPTF 98.6 (3.88) 38.1 (1.50) 19.1 (0.75)

C1220 1 1/6– 12 UN #12 SAE 117.3 (4.62) 38.1 (1.50) 19.1 (0.75)

C1600 1– 11 1/2 NPTF 127.0 (5.00) 44.5 (1.75) 22.4 (0.88)

C1620 1 5/16– 12 UN #16 SAE 142.7 (5.62) 57.2 (2.25) 28.4 (1.12)

C2000 1 1/4– 11 1/2 NPTF 143.0 (5.63) 57.2 (2.25) 28.7 (1.13)

C2020 1 5/8– 12 UN #20 SAE 165.1 (6.50) 69.9 (2.75) 35.1 (1.38)

C2400 1 1/2– 11 1/2 NPTF 143.0 (5.63) 69.9 (2.75) 35.1 (1.38)

C2420 1 7/8– 12 UN #24 SAE 184.2 (7.25) 76.2 (3.00) 38.1 (1.50)

C3200 2– 11 1/2 NPTF 165.1 (6.50) 88.9 (3.50) 44.5 (1.75)

C3220 2 1/2– 12 UN #32 SAE 228.6 (9.00) 101.6 (4.00) 50.8 (2.00)

Dimensions Inch equivalents for millimeter dimensions are shown in (**)

A (Both Ends)D

C Sq.

Free Flow

B

HPU Item #29 Hydraulic Power Unit - Item #29 - C820SHydraulic Power Unit - Item #29 - C820S

8-968-96

2502-K1.p65, dd

K32 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA

Ball Valves

K

Technical Information Series BV3H, BV4H

General Description

Series BV3H and BV4H are true 3-way and 4-way high pressure valves, incorporating many of the advanced features of the 2-way product. These products come in steel and are rated at 414 Bar (6000 PSI). Ports range from 1/4" to 2" with a variety of porting options.

Operation

The BV3H Series operates by rotating the handle 90° and BV4H operates through 180° rotation of the handle, depending on the flow path. A BV4H with ball #4 is 90° operation. There is no port-to-port overlap during transition.

Specifications

Maximum Pressure 414 Bar (6000 PSI)

Body Material Carbon Steel, Black Oxide

Ball Material Steel, Chrome Plated, Trunnion mount

Standard Pattern “L” Bore (3W), “T” Bore (4W)

Spindle Material Steel, Zinc Plated

Standard Handle T-Type Handle

Ball Seals Delrin + MoS2

Spindle Seals O-Rings + Bearing Stacks

Operating -30C° to +100°C Temperature (-22°F to +212°F)

Performance Curves

37838 10010

Flow

LPM

GPM

Pressure Drop Pressure Drop at Flow Curves, L-Bore "1" Ball

10 .7

20 1.4

30 2.1

40 2.8

PSI

3.5

4.1 Bar

P re ss u re

¼" ½" ¾" 1" 1¼"

1½"

2"

8/ "

Actuation Torque

1 1/4"

1 1/2"

2"

1"

1/4" 3/8" 1/2" 3/4"

10000

Line Pressure

2.0

1.0

3.0

A ct u at io n

To rq u e

(in -lb s x

Bar

PSI

Features

••••• Three dimensional balanced sealing for near zero leakage in any circuit.

••••• The unique thrust bearing spindle design reduces actuation torque and reduces the chance of the valve seizing when inactive for periods of time.

••••• Special seal design enables high port to port ΔP application suitability.

••••• A variety of ball patterns allows flexibility in many applications.

HPU Item #30 Hydraulic Power Unit - Item #30 - BV4H08S4SS1NAHydraulic Power Unit - Item #30 - BV4H08S4SS1NA

8-978-97

K33 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA

Ball Valves

K

Ordering Information Series BV3H, BV4H

Code Type

BV3H 3-Way

BV4H 4-Way

Code Type

N NPT Thread

S SAE Thread

B BSPP Thread

Code Type

A Locking Handle

★C 1 Way Limit Switch

★K 1 Way Limit Switch w/Lock

★ When selecting this option, your ball valve will come with limit switch bracket, but does not include the switch. The switch is sold separately (Part #LSB)

Code Type

1 Delrin

2 * PTFE

4 Peek

Code Type

S Steel

K Stainless Steel

Code Type

N Nitrile

V Fluorocarbon

E EPR

Code Size

04 1/4"

06 3/8"

08 1/2"

12 3/4"

16 1"

20 1 1/4"

24 1 1/2"

32 2"

Handle Phase 90° 45° 0° -45° -90° Stop

Ball ISO Circuit Ball Washer Code Symbol Pattern Type

1 L-Bore 3-Way Std

2 T-Bore 90° 3-Way Opt

3 T-Bore 180° 4-WayStd

4 X-Bore 90° 4-Way Opt

Code Type

S Steel

K Stainless Steel

Multiway Manifold Mount Valve Porting Options

BV3H and BV4H valves are designed with no port-to-port overlap (see ISO symbols) during transition. Use the table below to select the ball pattern ordering code.

Series Size Port Ball Pattern

Body Material

Ball & Stem Material

Ball Seals Options Design Series

NOTE:

Not required when ordering.

Stem Seals

* Valve pressure rating reduced.

Consult factory.

Weights Code kg (lbs.)

04 1.8 (4.0 ) 06 1.9 (4.2 ) 08 2.9 (6.4) 12 6.3 (13.9) 16 11.5 (25.4 ) 20 17.1 (37.7) 24 24.3 (53.6) 32 41.8 (92.2 )

HPU Item #30

8-988-98

K34 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA

Ball Valves

K

Dimensions Series BV3H, BV4H

Threaded Ports

Port Working Dimensions mm (in)

Code Size Pressure A B C-Dia. D E F G H

NPT and SAE Thread 04 1/4" 414 Bar 87.9 63.0 7.9 12.2 63.5 177.8 122.2 31.0

(6000 PSI) (3.46) (2.48) (0.31) (0.48) (2.50) (7.00) (4.81) (1.22)

06 3/8" 414 Bar 87.9 63.0 7.9 12.2 63.5 177.8 122.2 31.0

(6000 PSI) (3.46) (2.48) (0.31) (0.48) (2.50) (7.00) (4.81) (1.22)

08 1/2" 414 Bar 115.6 69.9 11.2 19.6 76.2 177.8 127.0 33.8

(6000 PSI) (4.55) (2.75) (0.44) (0.77) (3.00) (7.00) (5.00) (1.33)

12 3/4" 414 Bar 136.1 82.0 16.0 17.3 101.6 254.0 157.2 38.1

(6000 PSI) (5.36) (3.23) (0.63) (0.68) (4.00) (10.00) (6.19) (1.50)

16 1" 414 Bar 174.8 101.1 22.4 23.9 127.0 254.0 176.3 44.5

(6000 PSI) (6.88) (3.98) (0.88) (0.94) (5.00) (10.00) (6.94) (1.75)

20 1 1/4" 414 Bar 188.7 116.6 28.7 21.1 146.6 368.3 206.5 52.8

(6000 PSI) (7.43) (4.59) (1.13) (0.83) (5.77) (14.50) (8.13) (2.08)

24 1 1/2" 414 Bar 233.4 129.0 33.3 24.6 184.2 368.3 219.2 57.7

(6000 PSI) (9.19) (5.08) (1.31) (0.97) (7.25) (14.50) (8.63) (2.27)

32 2" 414 Bar 300.0 157.7 44.5 32.5 235.0 368.3 256.0 68.8

(6000 PSI) (11.81) (6.21) (1.75) (1.28) (9.25) (14.50) (10.08) (2.71)

F

H

B

G

D

A

E

C Dia.

HPU Item #30

8-998-99

K35 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA

Ball Valves

K

Seal Kit Accessories Series BV3H, BV4H

Code Type

BV3H 3-Way

BV4H 4-Way

Code Type

1 Delrin

2 * PTFE

4 Peek

Code Type

S Steel

Code Type

N Nitrile

V Fluorocarbon

E EPR

Code Size

04 1/4"

06 3/8"

08 1/2"

12 3/4"

16 1"

20 1 1/4"

24 1 1/2"

32 2"

Code Type

S Steel

Ordering Information

Code Type

SK Seal Kit

Handle Phase 90° 45° 0° -45° -90° Stop

Ball ISO Circuit Ball Washer Code Symbol Pattern Type

1 L-Bore

3-Way Std

2 T-Bore 90° 3-Way Opt

3 T-Bore 180° 4-WayStd

4 X-Bore 90° 4-Way Opt

Multiway Manifold Mount Valve Porting Options

BV3H and BV4H valves are designed with no port-to-port overlap (see ISO symbols) during transition. Use the table below to select the ball pattern ordering code.

Code Type

N NPT Thread

S SAE Thread

B BSPP Thread

SK

Accessory Series Size Port Body

Material Ball & Stem

Material Ball Seals Stem Seals Design

Series

NOTE:

Not required when ordering.

Ball Pattern

S S

* Valve pressure rating reduced.

Consult factory.

Ball Valve Seal Kits restore a ball valve to factory specifications, providing no erosion or metal-to-metal wear has taken place.

The Seal Kit includes all the o-rings, ball seals and thrust bearings that were originally installed at the factory. A sketch of these parts is provided at the right.

HPU Item #30

8-1008-100

K36 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA

Ball Valves

K

Locking Handle Kit Accessories Series BV3H, BV4H

BVHPLH: Standard Series 'BVHPLH-*' kit replaces the stopwasher with a stationary and moving plate, as illustrated below. As the handle is actuated, the moving plate aligns with one of the two locking positions in the stationary plate, enabling the valve to be locked in either fully closed or fully open position.

Ordering Information

BV3H and BV4H Standard Locking Code Size (Part Number)

04 1/4" BVHPLH-2

06 3/8" BVHPLH-2

08 1/2" BVHPLH-3

12 3/4" BVHPLH-4

16 1" BVHPLH-5

20 1 1/4" BVHPLH-6

24 1 1/2" BVHPLH-7

32 2" BVHPLH-8

HPU Item #30

8-1018-101

Electrical Snap action electrical switch recognized by Underwriters’ Laboratories, Inc. and CSA International

Electrical Connection ¹⁄₂ NPT female conduit connection with terminal block

Pressure Connection Wetted Material 1 ¹⁄₄ NPT Female

Temperature Range* Ambient: -40°F to +180°F

(-40°C to +82°C) Media: -40°F to +300°F

(-40°C to +149°C)

*Temperature limits change with O-Ring selection

Adjustment Concealed wrench flat adjustment with range scale

Shipping Weight Approximately 3 pounds

Neo-Dyn® Series 200P Pressure Switch/ Internal Adjustment

Operating Pressure Data

Standard Specifications Ordering Sequence — Select desired option for each category

DESCRIPTION

Versatile Nega-Rate® Belleville disc spring pressure switch for a wide range of applications. Series 200P (piston sensor) for hydraulic applications up to 10000 psig system pressure.

Weather Proof (NEMA 4 and 13)

When factory presetting is desired, stipulate set point, increasing or decreasing

Insert available option number or letter designation as required

Series Wetted Material Adjustable Range Electrical Form Enclosure Miscellaneous

200P

OPTIONS

Wetted Material 1 Aluminum port and piston, Teflon seal and Buna-N O-Ring Adjustable Range 2 14 psig dec. to 220 psig inc. (1.0 bar dec. to 15.2 bar inc.)

3 150 psig dec. to 1500 psig inc. (10.3 bar dec. to 103.4 bar inc.)

6 375 psig dec. to 3000 psig inc. (25.9 bar dec. to 206.9 bar inc.)

8 800 psig dec. to 10000 psig inc. (55.2 bar dec. to 689.5 bar inc.)

Electrical Form C 15 amp at 125 or 250 VAC; ¹⁄₈ hp at 125 VAC; ¹⁄₄ hp at 250 VAC;

.5 amp resistive, .04 amp inductive at 125 VDC CC 11 amp, ¹⁄₄ hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC;

.5 amp resistive at 125 VDC Z 15 amp at 125 or 250 VAC; ¹⁄₄ hp at 125 VAC; ¹⁄₂ hp at 250 VAC; 1 amp resistive, .5 amp inductive at 125 VDC Enclosure 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 Miscellaneous A Epoxy paint exterior — extra protection for severe environments B Viton O-Ring C EPR O-Ring E ⁷⁄₁₆" - 20 SAE port L Neon indicator light — 115 VAC M Gold electrical contacts for extremely low current applications P 5-Pin Brad Harrison connector (Reduce AC electrical rating to 8 amps)

— (Not for CC3 Electrical) W Stainless steel screws — exterior X UL and CSA Certified with CE Mark (Not available with L or P option) Special (Consult representative or factory)

Non-catalog adjustable range and/or set point, deadband and proof pressure Operating temperature capability from -65°F to +400°F Manual reset — decreasing only (available in C3 only) 10 amps 125 VDC electrical rating

Adjustable Range

Number

Deadband† (approximate) Maximum Recommended System Pressure

10000*

Proof Pressure

10000 10000

15000**

Adjustable Set Point Range

Increasing 20 to 220

200 to 1500 500 to 3000

1000 to 10000

Decreasing 14 to 202

150 to 1275 375 to 2700 800 to 9000

All values given in psig.

†The deadband increases as the adjustable set point is increased.

*Diminished safety factor equal to approximately 2:1.

**Diminished safety factor equal to approximately 1.3:1.

13 C 3 _

Ordering Procedure Example

Max.

Min.

HPU Item #32

Hydraulic Power Unit - Item #32Hydraulic Power Unit - Item #32

8-1028-102

7.0 Max.

3.6

.82

1.72

Conduit Connection

¹⁄₂ NPT

Pessure Port

¹⁄₄ NPT2.72

3.50

2.72

.37

3.50

.265 Dia.

Mtg. Holes (2 places)

1.18

2.85 Max.

1.12 .50

Snap Action Electrical Element

Terminal Strip

Adjustment

Actuator Minimum Bearing Points

Teflon and O-Ring Seal

Piston Pressure Port

Negative Rate Belleville Disc Spring

Series 200PField Adjustable 14 to 10000 psig

Envelope Dimensions

Electrical Form

Basic Principles of Design

28150 Industry Drive, Valencia, CA 91355 Tel: 661-295-4000 Fax: 661-294-1750

FORM "C"

(SPDT)

RED

BRN

BLU

NC1

INC

P

C1

NO1

GRN

SCREW

FORM "CC"

(DPDT)

RED

BRN

BLU

BLK

YEL

VIO

NC1

INC

P

C1

NO1

NC2

C2

NO2

GRN

SCREW

Form #109-rev.a

FORM "Z"

(DOUBLE BREAK)

BLKRED NC NC

BLU VIONO NO

INC

P

GRN

SCREW

HPU Item #32

Hydraulic Power Unit - Item #32Hydraulic Power Unit - Item #32

8-1038-103

50 For pricing info, call 1-888-WIKA-USA or visit www.wika.com

Panel Builder Gauge

All Stainless Steel Construction

Glycerine Filled Case

The Type 233.55 LBM is specifically designed and manufactured to exact panel builder requirements. With exclusive features, it is ideal when used for panel mount gauges in the oil and gas, refinery, petrochemical, and food & beverage industries.

Industrial Gauges Type 233.55

Datasheet: 233.55

Standard Features Nominal Case Size: 2½" (63 mm)

Case Material: 304 stainless steel with off-set vent plug

Front Flange: Stainless steel

Wetted Parts: 316 SS

Window Type & Material: Safety glass

Dial Material: White aluminum Liquid Fillable Gauge: Standard

Restrictor: Standard

Pointer Material/Type: Black aluminum

Accuracy: 2/1/2% of span ASME B40.100 Grade A

Connection Locations: LBM (lower back mount)

Media Operating Temperature: Max. 212°F

Ambient Operating Temperature: -4°F to 140°F (-20°C to 160°C) maximum;

-40°F to 140°F w/silicone case fill

Items without part numbers are available - consult factory.

Type 233.55

Datasheet 233.55

Size 2½"

Conn. Size ¼" NPT

Connection LBM/FF

Press. Scale PSI PSI/BAR1 PSI/KPA PSI/KG/CM2

30" Hg 4282811 4283078 4283337 4283591

30"-0-15 psi 4282829 4283086 4283345 4283604

30"-0-30 psi 4282837 4283094 4283354 4283613

30"-0-60 psi 4282845 4283107 4283362 4283621

30"-0-100 psi 4282854 4283115 4283370 4283639

30"-0-160 psi 4282862 4283124 4283388 4283647

30"-0-200 psi 4282870 4283133 4283396 4283655

15 psi 4282888 4283141 4283400 4283664

30 psi 4282896 4283159 4283418 4283672

60 psi 4282900 4283167 4283426 4283680

100 psi 4282918 4283175 4283434 4283698

160 psi 4282926 4283184 4283443 4283702

200 psi 4282934 4283192 4283451 4283710

300 psi 4282943 4283204 4283469 4283728

400 psi 4282951 4283214 4283477 4283736

600 psi 4282969 4283222 4283485 4283744

800 psi 4282977 4283230 4283494 4283753

1,000 psi 4282985 4283248 4283507 4283761

1,500 psi 4282994 4283256 4283515 4283779

2,000 psi 4283000 4283264 4283524 4283787

3,000 psi 4283018 4283273 4283532 4283795

5,000 psi 4283026 4283281 4283540 4283809

6,000 psi 4283034 4283299 4283558 4283817

10,000 psi 4283044 4283303 4283566 4283825

15,000 psi 4283052 4283311 4283574 4283834

20,000 psi 4283060 4283329 4283583 4283842

¹"PSI/BAR" denotes dual scale; PSI outside in black, BAR inside in red.

2"PSI/KG/CM²" denotes dual scale; PSI outside in black, KG/CM² inside in red.

Note: Vacuum scale: 30" Hg outside in black; 760 mm Hg inside in red.

Note: Stock items shown in bold, blue print.

Additional accessories available -see "Accessories" section in back of catalog

HPU Item #33-37Hydraulic Power Unit - Item #33-37Hydraulic Power Unit - Item #33-37

8-1048-104

STAUFF

STA

STA

Test hose with swivel nut

Protective cap

Test coupling

T8

Test 20 Type SKK Connection Thread M 16 x 2

T E

S T

The complete STAUFF-TEST-20-Type-SKK range is also available with hexagonal protection cap made of steel or plastic protection cap

Fast Coupling for:

• Monitoring and control of pressure

• Venting

• Sampling Fluids

Advantages:

• Coupling at system pressure level

• Connection is leakproof before piston valve is open

• Simple connection to measurement, control and switching devices

• Self locking metal protective cap

• Minimizes introduction of contamination to hydraulic systems

Working Pressure:

• Max. working pressure 9000 PSI (630 bar) For SKK type G, K and S the recommended working pressure of fitting manufacturer should be noted

• Connection under pressure up to 5800 PSI (400 bar) max.

Materials:

• Metal parts: Steel, Stainless Steel on request

• Seals:

Standard V = FPM-VITON Temperature range – 4˚F to +392˚F (– 20˚ C to + 200˚ C)

Optional P = NBR-BUNA Temperature range – 4˚F to +195˚F

(–20˚ C to + 90˚C)
E=EPDMEthylenePropylene(forBrakeFluid)

Temperature range – 40˚F to +302˚F (– 40˚ C to + 150˚ C)

•Hose: Polyamide Temperature range –31˚F to +212˚F
(–35˚C to +100˚ C)

Media:

•Suitableforhydraulicoilsandotherlowviscositymineral
basedfluids(Checkcompatibilityofsealmaterial)

• For use with other liquid or gaseous media please consult STAUFF for details

HPU Item #39Hydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6FHydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6F

8-1058-105

G d1 t 1 t 2

30°

0.

2.

d1

G

90° t 1 t 2 a d1

G

90° t 1 t 2 a

G

90° t 1 t 2

G d1

1, a t 1 t 2

12° d2

17 10

0.67" 0.4"

STAUFF

hM 16

Hex

G

T9

Test 20 Type SKK Connection Thread M 16 x 2

T E

S T

M8 x 1 SKK 20 – M8 x 1 – PA SKK 20 – M8 x 1 – VA O-Ring Type A

M10 x 1 SKK 20 – M10 x 1 – PA SKK 20 – M10 x 1 – VA O-Ring Type A

M12 x 1,5 SKK 20 – M12 x 1,5 – PC SKK 20 – M12 x 1,5 – VC O-Ring Type C

M14 x 1,5 SKK 20 – M14 x 1,5 – PB SKK 20 – M14 x 1,5 – VB Metal joint Type B

M16 x 1,5 SKK 20 – M16 x 1,5 – PB SKK 20 – M16 x 1,5 – VB Metal joint Type B

G 1/8 SKK 20 – G 1/8 – PC SKK 20 – G 1/8 – VC O-Ring Type C

G 1/4 SKK 20 – G 1/4 – PB SKK 20 – G 1/4 – VB Metal joint Type B

G 1/4 SKK 20 – G 1/4 – PC SKK 20 – G 1/4 – VC O-Ring Type C

G 3/8 SKK 20 – G 3/8 – PB SKK 20 – G 3/8 – VB Metal joint Type B

R 1/8 taper SKK 20 – R 1/8 K-PD SKK 20 – R 1/8 K-VD Taper Type D

R 1/4 taper SKK 20 – R 1/4 K-PD SKK 20 – R 1/4 K-VD Taper Type D

1/8 NPT SKK 20 – 1/8 NPT-PD SKK 20 – 1/8 NPT-VD Taper Type D

1/4 NPT SKK 20 – 1/4 NPT-PD SKK 20 – 1/4 NPT-VD Taper Type D

5/16 – 24 UNF SKK 20 – 5/16 UNF-PE SKK 20 – 5/16 UNF-VE O-Ring Type E

7/16 – 20 UNF SKK 20 – 7/16 UNF-PE SKK 20 – 7/16 UNF-VE O-Ring Type E

1/2 – 20 UNF SKK 20 – 1/2 UNF-PE SKK 20 – 1/2 UNF-VE O-Ring Type E

9/16 – 18 UNF SKK 20 – 9/16 UNF-PE SKK 20 – 9/16 UNF-VE O-Ring Type E

Thread h Hex Order No.

G Seal Type NBR (BUNA) FPM (VITON) (see below) (Standard)

Test Coupling with Protective Cap SKK

To order hexagonal protection cap, add “SK” to part number. To order Plastic Protection cap, add “KK” to part number.

Other port connections and seals on request.

Port Connections and Seals

Type A Type B Type C Type D Type E (ISO 6149)

G d1 d2 t1 t2 a G t1 t2 G d1 t1 t2 a G d1 t1 t2 a G d1 t1 t2

5/16 – 24 UNF

7/16 – 20 UNF

1/2 – 20 UNF

9/16 – 18 UNF

R 1/8 taper

R 1/4 taper

1/8 NPT

1/4 NPT

M12 x 1,5

G 1/8

G 1/4

M14 x 1,5

M16 x 1,5

G 1/4

G 3/8

M8 x 1

M10 x 1 mm

1.45

1.45

1.45

1.45

1.45

1.53

1.45

1.45

1.45

1.45

1.41

1.41

1.38

1.50

1.50

1.50

1.45 in

.67

.67

.67

.75

.87

.67

.75

.75

.87

.67

.67

.67

.67

.67

.67

.67

.75 mm in

0.37

9,5 + 0,1

11,5 + 0,1

0.45 mm in mm in

0.43

15,5

0.61

0.47

16,5

0.65 mm in

0.79

0.87

0.75

0.91 mm in mm in mm in

0.47

18,5

0.73

1,5

0.06

0.47

18,5

0.73

1,5

0.06

0.47

18,5

0.73

1,5

0.06

0.47

18,5

0.73

1,5

0.06 mm in

0.71

0.59

0.75 mm in mm in mm in mm in mm in

5,5

0.22

9,5

0.37 8,5

0.33

13,5

0.53 6,9

0.27

11,6

0.46

0.39

16,4

0.65

0.06

0.47

18,5

0.73

1,5

0.31

0.51

1,0

0.04

0.47

18,5

0.73

1,5

0.06 mm in

9,1

0.36 12,4

0.49

0.55 mm in mm in mm in

0.47

0.67

0.39

0.83

11,5

0.45

0.55

0.91

11,5

0.45

0.55 mm in

0.07

1,9

2,4

0.09 2,4

0.09 15,6

0.61

0.98

12,7

0.50

15,5

0.61

2,5

0.10 mm in

(Add C6F for Standard Finish)

HPU Item #39Hydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6FHydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6F

8-1068-106

SW17

Ød l 3 1.

1.

SW17

l 3

Ød

STAUFF STAUFF

STAUFF

SW17

SW2

ød

I 2

1.

STAUFF

SW 1

SW 2

SW17 h ød

T10

Test 20 Type SKK Connection Thread M 16 x 2

T E

S T

PN l2 l3 h SW 1 SW 2 Order No.*

Series PSI Pipe (Bar) Ød Type G Type K Type S

Test Coupling SKK (compression ring fittings acc. to DIN 2353) - Metric Tubing

* For ordering BUNA seals please replace “V” with “P”

* For EPDM seals replace “V” with “E”

Type G Test coupling complete with straight fitting

Type S Test coupling for compression ring assembly

Type K Test coupling for 24˚ cone fittings

15,5 0.61

15,5 0.61

16,5 0.65

17,5 0.69

0.83

19,5 0.77

20,5 0.81

0.98

1.18

1.22

14,5 0.57

16,5 0.65

16,5 0.65

17,5 0.69

19,5 0.77

0.71

0.94

1.02

1.18

1.34

0.79

0.79

0.87

0.87

0.98

1.10

1.18

1.26

1.65

1.77

0.79

0.79

0.87

0.87

0.87

1.10

1.18

1.42

1.61

1.89

1.93

1.93

1.93

1.97

2.05

2.09

2.17

57,5 2.26

2.36

64,5 2.54

1.93

1.93

1.93

1.93

50,5 1.99

2.05

2.17

57,5 2.26

2.36

64,5 2.54

0.94

0.94

0.94

1.06

1.18

1.26

1.42

1.61

1.81

2.17

0.94

0.94

0.94

0.94

1.06

1.18

1.42

1.61

1.81

2.17

0.55

0.67

0.75

0.87

1.06

1.26

1.42

1.61

1.97

2.36

0.67

0.75

0.87

0.94

1.06

1.18

1.42

1.81

1.97

2.36 mm in mm in mm in mm in mm in

6 SKK 20 – 6 L–VG SKK 20 – 6 L–VK SKK 20 – 6–VS

8 SKK 20 – 8 L–VG SKK 20 – 8 L–VK SKK 20 – 8–VS

4500 10 SKK 20 – 10 L–VG SKK 20 – 10 L–VK SKK 20 – 10–VS

(315) 12 SKK 20 – 12 L–VG SKK 20 – 12 L–VK SKK 20 – 12–VS

L

15 SKK 20 – 15 L–VG SKK 20 – 15 L–VK SKK 20 – 15–VS

18 SKK 20 – 18 L–VG SKK 20 – 18 L–VK SKK 20 – 18–VS

22 SKK 20 – 22 L–VG SKK 20 – 22 L–VK SKK 20 – 22–VS

2300 28 SKK 20 – 28 L–VG SKK 20 – 28 L–VK SKK 20 – 28–VS

(160) 35 SKK 20 – 35 L–VG SKK 20 – 35 L–VK SKK 20 – 35–VS

42 SKK 20 – 42 L–VG SKK 20 – 42 L–VK SKK 20 – 42–VS

6 SKK 20 – 6 S–VG SKK 20 – 6 S–VK SKK 20 – 6–VS

8 SKK 20 – 8 S–VG SKK 20 – 8 S–VK SKK 20 – 8–VS

9100 10 SKK 20 – 10 S–VG SKK 20 – 10 S–VK SKK 20 – 10–VS

(630) 12 SKK 20 – 12 S–VG SKK 20 – 12 S–VK SKK 20 – 12–VS

S

14 SKK 20 – 14 S–VG SKK 20 – 14 S–VK SKK 20 – 14–VS

16 SKK 20 – 16 S–VG SKK 20 – 16 S–VK SKK 20 – 16–VS

5800 20 SKK 20 – 20 S–VG SKK 20 – 20 S–VK SKK 20 – 20–VS

(400) 25 SKK 20 – 25 S–VG SKK 20 – 25 S–VK SKK 20 – 25–VS

30 SKK 20 – 30 S–VG SKK 20 – 30 S–VK SKK 20 – 30–VS

(315)

38 SKK 20 – 38 S–VG SKK 20 – 38 S–VK SKK 20 – 38–VS

(Add C6F for Standard Finish)

HPU Item #39Hydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6FHydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6F

8-1078-107

Atlantic Industrial Technologies

9 ELECTRICAL DATASHEETS

Circuit Protectionw w w . a u t o m a t i o n d i r e c t . c o m / c i r c u i t - p r o t e c t i o n e31–5

Company Information

Systems Overview

Programmable Controllers

Field I/O

Software

C-more & other HMI

Drives

Soft Starters

Motors & Gearbox

Steppers/ Servos

Motor Controls

Proximity Sensors

Photo Sensors

Limit Switches

Encoders

Current Sensors

Pressure Sensors

Temperature Sensors

Pushbuttons/ Lights

Process

Relays/ Timers

Comm.

Terminal Blocks & Wiring

Power

Circuit Protection

Enclosures

Tools

Pneumatics

Safety

Appendix

Product Index

Part # Index

Volume 14

UL489 or UL1077?

What are your Circuit Protection Requirements?

An understanding of circuit types and circuit protection products is critical to ensure their proper application.

See NEC Sections 100, 430 and 409 for definitions.

The proper sizing of an overcurrent protection device is the responsibility of the customer and should be determined using the application standards of the NEC (National Electric Code), CEC (Canadian Electrical Code) or other applicable standards. Per fine print note of 2008 NEC

Section 100 "A current in excess of rating may be accommodated by certain equipment and conductors for a given set of conditions.

Therefore, the rules for overcurrent protection are specific for particular situations."

UL489

Branch Protection

UL1077

Supplementary Protection

What You Need to Know and Look For In Specifications Certifications – Standards – Acceptance

UL489

Branch Protection

UL1077

Supplementary Protection

• UL489 Listed or Recognized

• CSA C22.2 No. 5

• International ratings available depending on breaker type

• UL Recognized under UL1077

• CSA 22.2 No. 285

• IEC 60947-2 or IEC 898

Function

• Opens automatically on Overload and Short Circuit when properly applied with-in its ratings

• Protects wire and cable against Overload and Short Circuit

• Opens automatically on Overload and Short Circuit

• Provides additional equipment protection where branch circuit protection is already provided or not required

• Not suitable for the protection of branch circuit conductors Applications

• Branch circuit protection in control panels, panelboards, switchboards and motor control centers

• Motor overload and motor short circuit protection (UL489 Recognized motor circuit protectors) for control panels and motor control centers

• Used within appliances or other electrical equipment such as control circuits, control power transformers, relays, PLC I/O points and lighting circuits

• Ideal replacement for fuses that are applied as supplementary protection

Features

• Bolted down or DIN-rail mounted

• External handle mechanisms available

• Field mounted accessories

• Stand alone branch circuit protection

• Various levels of protection (curve type)

• High voltage and interruption levels (up to 100 kAIC @ 480V)

• DIN-Rail mounted

• Field mounted accessories

• Current limiting

• Various levels of protection (curve type)

• 10 kAIC @ 240 VAC

• 6 kAIC @ 277 VAC and 5 kAIC @ 480 VAC

• 10 kAIC @ 65 VDC kAIC = thousands of Amps interrupt capacity Summary

A Supplementary Protector can’t Be used for Branch Circuit Protection.

Understanding the difference between Branch Circuit Protection and Supplementary Protection helps to ensure their proper use.

Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080

9-19-1

Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–34 Volume 14

3P Series Molded Case Circuit Breakers Overview

Overview Designed to provide branch and feeder circuit protection in industrial control panels, this line of Molded Case Circuit Breakers supplies protection against overload in conductors and short circuit in connected equipment such as motors.

They are UL listed for installation in UL 508 control panels. Their small size, in relation to standard circuit breakers or other comparable devices, saves panel space. Four frame sizes and all standard accessories are available.

Listings

• UL 489MCCB, File: E7819

• Field-installed accessories:

UL file E64983

• CSA 22.2 No.5, File: 43556

• IEC 157-1

• NEMA Standards Pub. No. AB1-1993

Features

• UL489 listed performance for branch circuit overcurrent protection and disconnectingmeans

• Patented contact conductor designs featuring high-speed “blow-open” action, providing superior performance when high level fault currents produce extra-ordinary electromechanical forces

• Advanced arc extinguishing technology

• Toggle handle provides three positions (on/off/tripped) alongwith visual indicators

• Manufactured in ISO 9000 certified facilities

• HACR (heating, air conditioning and refrigeration) rated

• G-Frame and F-Frame breakers are suitable for reverse feed

• K-Frame and L-Frame breakers include 3-pole adjustablemagnetic trip.

G 3P - 020 - AUX

Molded Case Circuit Breaker Series (by frame size) G: 15 to 100 Amp F: 60 to 225 Amp K: 250 to 400 Amp L: 400 to 600 Amp

Accessory Description Code AUX: auxiliary contact UVAC: undervoltage release STAC: shunt trip AC STDC: shunt trip DC

Amp Rating

3 Pole

UVDC: undervoltage release

Molded Case Circuit Breakers Part Numbering System

Molded Case Circuit Breakers Technical Specifications

Circuit Breaker Type

Ampere Rating at 40°C

No.

Poles

Volts Type of

Trip*

Federal Specification W-C-375b

UL 489 Interrupting Ratings (rms Symmetrical Amperes) (kA)

AC DC

Volts AC (50/60 Hz) Volts DC

240 480 600 250** G-Frame 15 -100 3 480 250 N.I.T.U 13b 65 22 – 10

F-Frame 60 - 225 3 600 250 N.I.T.U 22a 65 35 18 10

K-Frame 250 - 400 3 600 250 I.T.U 23a 65 35 25 10

L-Frame 400 - 600 3 600 250 I.T.U 23a 65 35 25 22

*Note: N.I.T.U denotes non-interchangeable trip unit. I.T.U denotes interchangeable trip unit.

**Note: For DC or 1-phase AC applications, use the two outside poles of the 3-pole circuit breaker

Manufactured by Eaton Corporation

Note: These parts available for sale to North American locations only.

9-29-2

Circuit Protectionw w w . a u t o m a t i o n d i r e c t . c o m / c i r c u i t - p r o t e c t i o n e31–35

Information

Systems Overview

Programmable Controllers

Field I/O

Software

C-more & other HMI

Drives

Soft Starters

Motors & Gearbox

Steppers/ Servos

Motor Controls

Proximity Sensors

Photo Sensors

Limit Switches

Encoders

Current Sensors

Pressure Sensors

Temperature Sensors

Pushbuttons/ Lights

Process

Relays/ Timers

Comm.

Terminal Blocks & Wiring

Power

Circuit Protection

Enclosures

Tools

Pneumatics

Safety

Appendix

Product Index

Part # Index

Volume 14

G-Frame Accessory Selection Guide Part Number Price Description GHMVD06B <---> NEMA 1/12 rotary handle for G-Frame. Position indicating; lock-off feature. Shaft length: 6”

GHMVD12B <---> NEMA 1/12 rotary handle for G-Frame. Position indicating; lock-off feature. Shaft length: 12”

F0S03C <---> NEMA 1/12 flexible shaft handle for G-Frame. Flange mounted. Lockable. Shaft length: 3’

F0S06C <---> NEMA 1/12 flexible shaft handle for G-Frame. Flange mounted. Lockable. Shaft length: 6’

3TA100G6K <---> Multi-wire connector to allow 6 wires to be connected to the G-frame. UL for copper only. 14-6AWG. Package of 3

GDIN <---> DIN rail clip adapter to allow mounting of G-Frame unit on 35mm DIN rail. Pkg of 1 includes mounting hardware.

3P Series Molded Case Circuit Breakers 15 - 100 Amp G-Frame

G-Frame Series Three Pole Molded Case Circuit Breakers

Part Number Price Description Pre-Installed Accessories* Ampere Rating Voltage InterruptCapacity

G3P-015 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

None

240VAC

480VAC

250VDC**

65kA 22kA 10kA

G3P-015-AUX <---> With auxiliary contact, SPDT

G3P-020 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

None

G3P-020-AUX <---> With auxiliary contact, SPDT

G3P-025 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

None 25

G3P-030 <---> None

G3P-030-AUX <--->

Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

With auxiliary contact, SPDT

G3P-030-STAC <---> With 120 VAC shunt trip

G3P-030-STDC <---> With 24 VDC shunt trip

G3P-030-UVAC <---> With 120 VAC undervoltage release

G3P-040 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

None 40

G3P-050 <---> None 50

G3P-060 <---> None

G3P-060-AUX <--->

Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

With auxiliary contact, SPDT

G3P-060-STAC <---> With 120 VAC shunt trip

G3P-060-STDC <---> With 24 VDC shunt trip

G3P-060-UVAC <---> With 120 VAC undervoltage release

G3P-070 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

None 70

G3P-080 <---> None 80

G3P-090 <---> None 90

G3P-100 <--->

Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

None

G3P-100-AUX <---> With auxiliary contact, SPDT

G3P-100-STAC <---> With 120 VAC shunt trip

G3P-100-STDC <---> With 24 VDC shunt trip

G3P-100-UVAC <---> With 120 VAC undervoltage release

*Note: Available accessories are pre-installed on G-Frame and F-Frame Molded Case Circuit Breakers. They are not field installable or interchangeable.

** For DC or 1-phase AC applications, use the two outside poles of the 3-pole circuit breaker

G-Frame circuit breakers are available as a single unit, or with accessories pre-installed only. Accessories are not field installable on this frame size. G-Frame breakers are suitable for reverse feed use. All breakers include base mounting hardware for panel mount applications.

G3P-40

GHMVD12B

GDIN

F0S03C

3TA100G6K

AWG Wire Range Specifications Circuit Breaker

Ampere Rating

Wire Type

AWG Wire Range

Metric Wire Range mm2

G-Frame 15 - 20

Cu/AI 14 - 10 2.5 - 4

25 - 100 10 - 1/0 4 - 50

G-Frame Electrical Ratings

Volts Frequency Amperes ContactArrangement G-Frame Auxiliary Switch 240 VAC 50/60 Hz 6 1a/1b - SPDT

G-Frame Shunt Trip 120 VAC 50/60 Hz 1.1

24 VDC DC 5.7

G-Frame Undervoltage Release Mechanism

120 VAC 50/60 Hz 0.05

Dropout Voltage Pickup Voltage Min Max Max

38.5 VAC 77.0 VAC 93.5 VAC

Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080

9-39-3 http://www.automationdirect.com/pn/G3P-030-STAC http://www.automationdirect.com/pn/G3P-030-STDC http://www.automationdirect.com/pn/G3P-030-UVAC http://www.automationdirect.com/pn/G3P-060-STAC http://www.automationdirect.com/pn/G3P-060-STDC http://www.automationdirect.com/pn/G3P-060-UVAC http://www.automationdirect.com/pn/G3P-100-STAC http://www.automationdirect.com/pn/G3P-100-STDC http://www.automationdirect.com/pn/G3P-100-UVAC http://www.automationdirect.com/pn/G3P-015-AUX http://www.automationdirect.com/pn/G3P-020-AUX http://www.automationdirect.com/pn/G3P-030-AUX http://www.automationdirect.com/pn/G3P-060-AUX http://www.automationdirect.com/pn/G3P-100-AUX http://www.automationdirect.com/pn/3TA100G6K http://www.automationdirect.com/pn/3TA100G6K http://www.automationdirect.com/pn/GHMVD06B http://www.automationdirect.com/pn/GHMVD12B http://www.automationdirect.com/pn/GHMVD12B http://www.automationdirect.com/pn/G3P-015 http://www.automationdirect.com/pn/G3P-020 http://www.automationdirect.com/pn/G3P-025 http://www.automationdirect.com/pn/G3P-030 http://www.automationdirect.com/pn/G3P-040 http://www.automationdirect.com/pn/G3P-050 http://www.automationdirect.com/pn/G3P-060 http://www.automationdirect.com/pn/G3P-070 http://www.automationdirect.com/pn/G3P-080 http://www.automationdirect.com/pn/G3P-090 http://www.automationdirect.com/pn/G3P-100 http://www.automationdirect.com/pn/F0S03C http://www.automationdirect.com/pn/F0S06C http://www.automationdirect.com/pn/F0S03C http://www.automationdirect.com/pn/GDIN

Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–36

3P Series Molded Case Circuit Breakers 15 - 100 Amp G-Frame

M aximum

I n t e r r u p t i n g R a t i n g ( S e e T a b u l a t i o n A b o v e

M inimum

.5

.3

.2

.1

.05

.03

.02

.01

.005

.003

.002

.001

1,000

5,000

3,000

2,000

HO

UR

M

IN

U

TE

HO

UR

S

10,000

.5

.3

.2

.1

.05

.03

.02

.01

.005

.003

.002

.001

1,000

5,000

3,000

2,000

HO

UR

M

IN

U

TE

HO

UR

S

8060 907050 10

,0

0, ,0

,0

,0

,0

,0

,0

,0

,0

,0

8060 907050

0, ,0

,0

,0

,0

,0

,0

,0

,0

10,000

M ax im um Vo l ts

Type

G 3P

Con t inuous A mperes

15-60 70-100

G 3 P

500-1300 1300-1800

S y m m e t r i c a l R M S A m p e r e s 240 Volts

65,000

400-1100 700-1300

480 Volts 22,000

C U R R E N T I N P E R C E N T O F B R E A K E R T R I P U N I T R A T I N G

C i r c u i t B r e a k e r T i m e / C u r r e n t C u r v e s C a t a l o g T y p e G 3 P 1 5 - 1 0 0 A m p e r e s F o r a p p l i c a t i o n a n d c o o r d i n a t i o n p u r p o s e s o n l y . B a s e d o n 4 0 ˚ C a m b i e n t , c o l d s t a r t . C o n n e c t e d w i t h f o u r ( 4 ) f e e t o f r a t e d w i r e ( 6 0 / 7 5 ˚ C ) p e r t e r m i n a l . T e s t e d i n o p e n a i r w i t h c u r r e n t i n a l l p o l e s e x c e p t f o r i n s t a n t a n e o u s t r i p , s e e b e l o w

B r e a k e r

B r e a k e r I n s t a n t a n e o u s T r i p , A m p e r e s

A C V o l t s 6 0 H z

S i n g l e P o l e 2 P o l e s i n S e r i e s

I n t e r r u p t i n g R a t i n g ( U L L i s t e d ) B r e a k e r T y p e

I n s t a n t a n e o u s T r i p ( S e e T a b u l a t i o n a b o v e )

M a x i m u m I n t e r r u p t i n g T i m e

C U R R E N T I N P E R C E N T O F B R E A K E R T R I P U N I T R A T I N G

T

IM

E

IN

S E

C O

N D

S T

IM

E

IN

S

E C

O N

D S

9-49-4

Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–50

3P Series Molded Case Circuit Breakers – Dimensions

4.875 (123.83)

2.625 (66.65)

.348 (8.83) Dia., 6 Holes in Cover.141 (3.57) Dia. 4 Holes

.281 (7.14) Dia C'Bores

.18 (4.57) Deep For Mounting Purposes

3.000 (76.17)

7̊

OFF

Front View Side View

On Off

.450 (11.43) diameter 6 holes

.110(2.8) dia.

x .310(7.9) deep, 2 holes accept #6 (M3.5) thread cutting screws

Push to Trip

6.000 (152.40)

3.375 (85.73)

.197(5.00) diameter hole

.328(8.33) diameter c'bore 1.938(49.23) deep from top.

.344(8.74) diameter c'bore .656(16.66) deep from bottom.

4 mounting holes for .164-32 (No. 8) x 1.500( M4 x0.7x 38.10) mounting screws.

4.13(105.0)

Side ViewFront View

60 - 225 Amp F-Frame

15 - 100 Amp G-Frame inches(mm) inches(mm)

9-59-5

Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–52

Rotary Handle Accessory Selection Guide Part Number Price Description GHMVD06B NEMA 1/12 black rotary…