B

P P -1 .0

G -0

X X

X .d g n

BARKLEY POWER PLANT

CUMBERLAND RIVER, KENTUCKY

UNITS 1-4 EXCITATION SYSTEM REPLACEMENT

Nashville District of Engineers

US Army Corps

V

IC

IN

IT

Y M

A P

S

G-001

S T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

P R

O J E

C T

L

O C

A T

IO

N A

N D

R

H E

R N

A N

D E

Z

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/2

/2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

G-001SHEET NAME:G2hdcbpe Bill P. ElamBY USERNAME:DATE AND TIME PLOTTED: 8/27/2015 3:55:21 PM

DRAWING NUMBER TITLECADD FILE NAME

NO.

SHEET

DRAWING NUMBER TITLESHEET NUMBER

INDEX OF DRAWINGS

Q9-79/53

Q9-79/58

Q9-79/114.1

Q9-79/115.1

Q9-79/225A.1

Q9-79/225B.2

Q9-79/225C.1

Q9-79/225D.3

Q9-79/226A.3

Q9-79/226B.3

Q9-79/328A.1

Q9-79/624.4

Q9-79/701.10

Q9-79/702.13

Q9-79/704.3

Q9-79/705.3

Q9-79/707.6

Q9-79/708.6

Q9-79/709.5

Q9-79/710.5

Q9-79/750.23

Q9-79/751.8

Q9-79/752.13

Q9-79/754A.1

Q9-79/757.14

Q9-79/758.9

Q9-79/759.10

Q9-79/762.9

Q9-79/328C

Q9-79/700.9

Q9-79/755.6

Q9-79 53.TIF

Q9-79 58.TIF

Q9-79 114.1.TIF

Q9-79 115.1.TIF

Q9-79 225A.1.TIF

Q9-79 225B.1.TIF

Q9-79 225C.1.TIF

Q9-79 225D.3.TIF

Q9-79 226A.3.TIF

Q9-79 226B.3.TIF

Q9-79 328A.1.TIF

Q9-79 328C.TIF

Q9-79 624.4.DGN

Q9-79 700.9.DGN

Q9-79 701.10.DGN

Q9-79 702.13.DGN

Q9-79 704.3.DGN

Q9-79 705.3.DGN

Q9-79 707.6.DGN

Q9-79 708.6.DGN

Q9-79 709.5.DGN

Q9-79 710.5.DGN

Q9-79 750.23.DGN

Q9-79 751.8.DGN

Q9-79 752.13.DGN

Q9-79 754.12.DGN

Q9-79 754A.1.DGN

Q9-79 755.6.DGN

Q9-79 757.14.DGN

Q9-79 758.9.DGN

Q9-79 759.10.DGN

Q9-79 762.9.DGN

HEATING, VENTILATING & AIR CONDITIONING EQUIPMENT SECTIONS

CONCRETE OUTLINE, GEN. AND ELEC. BAY FLOOR, EL.347.0 - SHEET 1

REINFORCEMENT, GEN. AND ELEC. BAY FLOOR, BEAM ELEVATIONS

ELECTRICAL, 480 VOLT EQUIPMENT BOARD NO.1, AND UNIT BOARDS NO.1-4

ELECTRICAL, 480 VOLT EQUIPMENT BOARD NO.2 AND UNIT BOARDS NO.3

ELECTRICAL, 480 VOLT EQUIPMENT BOARDS, NO.4, 5 AND 6

ELECTRICAL, ANNUNCIATOR TROUBLE POINTS AND SCHEMATIC DIAGRAMS

Q9-79/754.12

B P

P -1 .0

G -0

X X

X .d g n

G-002

S T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

R

H E

R N

A N

D E

Z

Q9-79/750.24 Q9-79 750.24.DGN

Q9-79/702A.5 Q9-79 702A.5.DGN

Q9-79/582.3

Q9-79/583.3

Q9-79/584.3

Q9-79 591.3.TIF

MECHANICAL, EXPOSED PIPING, UNIT BAY NO. 3, PLAN - EL. 331.0

MECHANICAL, EXPOSED PIPING, UNIT BAYS, DETAILS - SHEET 1

Q9-79/589

Q9-79/581.3

Q9-79/591.3

Q9-79 592.1.TIF MECHANICAL, EXPOSED PIPING, UNIT BAYS, DETAILS - SHEET 2

Q9-79/593.1

Q9-79/592.1

Q9-79 581.3.TIF

Q9-79 582.3.TIF MECHANICAL, EXPOSED PIPING, UNIT BAY NO. 2, PLAN - EL. 331.0

CONCRETE OUTLINE, UNIT BAYS, SPIRAL CASE - ROOF,SHEET 4

CONCRETE OUTLINE, UNIT BAYS, SPIRAL CASE - ROOF, SHEET 3

CONCRETE OUTLINE, UNIT BAYS, SPIRAL CASE - ROOF, SHEET 2

CONCRETE OUTLINE, UNIT BAYS, SPIRAL CASE - ROOF, SHEET 1

ARCHITECTURAL, UNITS 3 AND 4, GENERATOR FLOOR PLAN - EL. 347.0

Q9-79 583.3.TIF

MECHANICAL, EXPOSED PIPING, UNIT BAY NO. 1, PLAN - EL. 331.0

ARCHITECTURAL, UNITS 1 AND 2, GENERATOR FLOOR, PLAN - EL. 347.0

CONCRETE OUTLINE, GEN. AND ELEC. BAY FLOOR, EL.347.0 - SHEET 2

REINFORCEMENT, GEN. AND ELEC. BAY FLOOR, EL. 347.0 - SHEET 1

Q9-79 584.3.TIF MECHANICAL, EXPOSED PIPING, UNIT BAY NO. 4, PLAN - EL. 331.0

Q9-79 589.TIF MECHANICAL, EXPOSED PIPING, UNIT BAYS, ACTUATOR INSTRUMENT LINES

Q9-79_593.1.TIF MECHANICAL, EXPOSED PIPING, UNIT BAYS, DETAILS - SHEET 3

Q9-79/579

Q9-79/580

Q9-79 579.TIF

Q9-79 580.TIF

Q9-79/594.2 Q9-79 594.2.TIF MECHANICAL, EXPOSED PIPING, UNIT BAYS, DETAILS - SHEET 4

Q9-79/622.3 Q9-79 622.3.TIF HEATING AND VENTILATING EQUIPMENT, ARRANGEMENT AT EL. 331.0 AND 315.0

MECHANICAL, HEATING & VENT., UNIT BAYS EL. 331.0, SECTIONS

Q9-79/631.3

Q9-79/632.2

Q9-79/633.2

Q9-79/635.3

Q9-79/630.1

Q9-79/636.3

Q9-79 637.1.TIF

Q9-79/638.2

Q9-79/637.1

Q9-79 630.1.TIF

Q9-79 631.3.TIF

Q9-79 632.2.TIF

Q9-79 633.2.TIF

Q9-79 635.3.TIF

Q9-79_638.2.TIF MECHANICAL, HEATING & VENT., UNIT BAY 1 EL. 331.0, PLAN

Q9-79/639.1 Q9-79 639.1.TIF

Q9-79/640.2 Q9-79 640.2.TIF

MECHANICAL, EXPOSED PIPING, UNIT BAYS NO. 3 & 4, PLANS - EL. 377.0 & 347.0

MECHANICAL, EXPOSED PIPING, UNIT BAYS NO. 1 & 2, PLANS - EL. 377.0 & 347.0

Q9-79/629.3 Q9-79 629.3.TIF MECHANICAL, HEATING, VENT. & AIR CONDITIONING- SERVICE BAY 347.0, PLAN

MECHANICAL, HEATING, VENT. & AIR COND.- SERVICE BAY 347.0, SECS.-SHT. 2

MECHANICAL, HEATING, VENT. & AIR COND.- SERVICE BAY 347.0, SECS.-SHT. 1

MECHANICAL, HEATING & VENT., UNIT BAYS 1 & 2 EL.347.0, PLAN & SEC.

Q9-79/634.2 Q9-79 634.2.TIF MECHANICAL, HEATING & VENT., UNIT BAYS EL. 347.0, SECTIONS

MECHANICAL, HEATING & VENT., SERVICE BAY 331.0, PLAN

Q9-79_636.3.TIF MECHANICAL, HEATING & VENT., SERVICE BAY EL 347.0 & 331.0, SECTIONS

MECHANICAL, HEATING & VENT., SERVICE BAY EL.331.0, SECTIONS

MECHANICAL, HEATING & VENT., UNIT BAYS 2 AND 3 EL. 331.0, PLAN

MECHANICAL, HEATING & VENT., UNIT BAY 4 EL. 331.0, PLAN

Q9-79/641 Q9-79 641.DGN

Q9-79/774.4 Q9-79 774.4.DGN

Q9-79/773.4

Q9-79/775.3

Q9-79/772.5 Q9-79 772.5.DGN

Q9-79 773.4.DGN

Q9-79 775.3.DGN

Q9-79/771.9 Q9-79 771.9.DGN

Q9-79 809.TIF

Q9-79 810.TIF

Q9-79 811.TIF

Q9-79 812.TIF

Q9-79 813.TIF

Q9-79 818.TIF

Q9-79 819.TIF

Q9-79 820.TIF

Q9-79 821.TIF

Q9-79 822.TIF

Q9-79/827.3 Q9-79 827.3.TIF

Q9-79 831.TIF

Q9-79 832.TIF

Q9-79 830.TIF

Q9-79 833.TIF

Q9-79 834.TIF

Q9-79 839.TIF

Q9-79 841.TIF

Q9-79 842.TIF

Q9-79 840.TIF

Q9-79 843.TIF

Q9-79 844.TIF

Q9-79 847.TIF

Q9-79 848.TIF

Q9-79 845.TIF

Q9-79 878.TIF

Q9-79 880.TIF

Q9-79/881 Q9-79 881.TIF

CONTRACT DRAWINGS

Q9-79/845A Q9-79 845A.TIF

Q9-79/764.12

Q9-79/769.4

Q9-79/770.5 Q9-79 770.5.DGN

Q9-79 764.12.DGN

Q9-79/621.3 Q9-79 621.3.TIF MECHANICAL, HVAC EQUIPMENT ARRANGEMENT, AT EL. 381.0, 366.0, AND 347.0

Q9-79/765.12 Q9-79 765.12.DGN

Q9-79 769.4.DGN

Q9-79/810.2

Q9-79/811.3

Q9-79/812.5

Q9-79/813.2

Q9-79/818.6

Q9-79/830.4

Q9-79/831.4

Q9-79/832.3

Q9-79/833.3

Q9-79/834.3

Q9-79/839.2

Q9-79/840.4

Q9-79/841.2

Q9-79/842.3

Q9-79/843.2

Q9-79/844.4

Q9-79/845.2

Q9-79/847.1

Q9-79/848.1

Q9-79/878.1

Q9-79/880.1

E-601

E-501

E-402

E-401

E-303

E-302

E-301

E-202

E-201

E-101

S-102

S-101

ED402

ED401

ED301

ED201

ED101

G-005

G-004

G-003

G-002

G-001

BPP-1.02-E-601

BPP-1.02-E-501

BPP-1.02-E-402

BPP-1.02-E-401

BPP-1.02-E-303

BPP-1.02-E-302

BPP-1.02-E-301

BPP-1.02-E-202

BPP-1.02-E-201

BPP-1.02-E-101

BPP-1.02-S-102

BPP-1.02-S-101

BPP-1.02-ED-402

BPP-1.02-ED-401

BPP-1.02-ED-301

BPP-1.02-ED-201

BPP-1.02-ED-101

BPP-1.02-0-0/5

BPP-1.02-0-0/4

BPP-1.02-0-0/3

BPP-1.02-0-0/2

BPP-1.02-0-0/1

BPP-1.02_E-601.dgn

BPP-1.02_E-501.dgn

BPP-1.02_E-402.dgn

BPP-1.02_E-401.dgn

BPP-1.02_E-303.dgn

BPP-1.02_E-302.dgn

BPP-1.02_E-301.dgn

BPP-1.02_E-202.dgn

BPP-1.02_E-201.dgn

BPP-1.02_E_101.dgn

BPP-1.02_S_102.dgn

BPP-1.02_S_101.dgn

BPP-1.02_ED402.dgn

BPP-1.02_ED401.dgn

BPP-1.02_ED301.dgn

BPP-1.02_ED201.dgn

BPP-1.02_ED101.dgn

BPP-1.02_G-005.dgn

BPP-1.02_G-004.dgn

BPP-1.02_G-003.dgn

BPP-1.02_G-002.dgn

BPP-1.02_G-001.dgn

IN

D

E X O

F D

R A

W

IN

G S

S H

E E

T O

F

CS-1 CS-1.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-1

CS-2 CS-2.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-2

CS-3 CS-3.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-3

CS-4 CS-4.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-4

CS-5 CS-5.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-5

CS-6 CS-6.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-6

CS-7 CS-7.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-7

CS-8 CS-8.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-8

CS-9 CS-9.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-9

COM DIAG. SHT1.DGNCOM DIAG. SHT. 1

GENERAL REFERENCE DRAWINGS

234244.6 234244.6.TIF

227953.4 227953.4.TIF OIL PIPING AND WIRING DIAGRAM HYDRAULIC TURBINE

971191 SHT 2A 971191-SHT-2A.TIF WOODWARD PMG WIRING DIAGRAM

CS-10

CS-11

CS-12

CS-13

CS-14

CS-15

CS-16

CS-17

CS-18

CS-19

CS-20

CS-21

CS-22

CS-23

CS-24

CS-25

CS-26

CS-27

CONDUIT AND CABLE SCHEDULE SHEET CS-14

CONDUIT AND CABLE SCHEDULE SHEET CS-25

CONDUIT AND CABLE SCHEDULE SHEET CS-26

CONDUIT AND CABLE SCHEDULE SHEET CS-27

CS-10.TIF

CS-11.TIF

CS-12.TIF

CS-13.TIF

CS-14.TIF

CS-15.TIF

CS-16.TIF

CS-17.TIF

CS-18.TIF

CS-19.TIF

CS-20.TIF

CS-21.TIF

CS-22.TIF

CS-23.TIF

CS-24.TIF

CS-25.TIF

CS-26.TIF

CS-27.TIF

CONDUIT AND CABLE SCHEDULE SHEET CS-10

CONDUIT AND CABLE SCHEDULE SHEET CS-11

CONDUIT AND CABLE SCHEDULE SHEET CS-12

CONDUIT AND CABLE SCHEDULE SHEET CS-13

CONDUIT AND CABLE SCHEDULE SHEET CS-15

CONDUIT AND CABLE SCHEDULE SHEET CS-16

CONDUIT AND CABLE SCHEDULE SHEET CS-17

CONDUIT AND CABLE SCHEDULE SHEET CS-18

CONDUIT AND CABLE SCHEDULE SHEET CS-19

CONDUIT AND CABLE SCHEDULE SHEET CS-20

CONDUIT AND CABLE SCHEDULE SHEET CS-21

CONDUIT AND CABLE SCHEDULE SHEET CS-22

CONDUIT AND CABLE SCHEDULE SHEET CS-23

CONDUIT AND CABLE SCHEDULE SHEET CS-24

MECHANICAL, HEATING & VENT., UNIT BAYS 3 AND 4 EL. 347.0, - PLAN

Q9-79/809.6

Q9-79/819.5

Q9-79/820.5

EXCITER NETWORK DIAGRAM

EXCITER EXTERNAL CONNECTIONS- INSTALL

CONROL ROOM MODIFICATIONS - INSTALL

RELAY BOARD MODIFICATIONS AND REMOTE HMI - INSTALL

DC BUS ROUTE IN GENERATOR HOUSING - INSTALL, SHEET 3 OF 3

DC BUS ROUTE IN GENERATOR HOUSING - INSTALL, SHEET 2 OF 3

DC BUS ROUTE IN GENERATOR HOUSING - INSTALL, SHEET 1 OF 3

DC EQUIPMENT - INSTALL

AC EQUIPMENT - INSTALL

ONE LINE DIAGRAM - EQUIPMENT INSTALL

DC BUS CONCRETE PENETRATION REGION, EL. 331.0 - INSTALL

CONCRETE MODIFICATIONS AND SUGGESTED EQUIPMENT LAYOUT - INSTALL

CONTROL ROOM MODIFICATIONS - REMOVAL

RELAY BOARD MODIFICATIONS - REMOVAL

EXISTING EXCITATION SYSTEM - REMOVAL

EQUIPMENT BEING REMOVED ON GENERATOR FLOOR

ONE LINE DIAGRAM - EQUIPMENT REMOVAL

AREA AVAILABLE TO CONTRACTORS DURING CONSTRUCTION

INDEX OF DRAWINGS, SHEET 3 OF 3

INDEX OF DRAWINGS, SHEET 2 OF 3

INDEX OF DRAWINGS, SHEET 1 OF 3

PROJECT LOCATION AND VICINITY MAPS

ARRANGEMENT, GENERATOR FLOOR EL.347.0

ARRANGEMENT, LONGITUDINAL SECTIONS AT CENTERLINE OF UNITS

ELECTRICAL, MAIN CONTROL AND INSTRUMENT BOARD

ELECTRICAL, MAIN RELAY BOARD

ELECTRICAL, CONNECTION DIAGRAM SHEET 3, 154 KV BAYS 1-4 INCLUSIVE

ELECTRICAL, RECORDING INSTRUMENT BOARD

ELECTRICAL, 15 KV SWITCHGEAR ARRANGEMENT - SHEET 1

ELECTRICAL, 15 KV SWITCHGEAR ARRANGEMENT - SHEET 2

ELECTRICAL, LIGHTING SYSTEM-SWITCHBOARD AND SINGLE LINE DIAGRAM

POWERHOUSE, MAIN SINGLE LINE DIAGRAM

POWERHOUSE, MAIN SINGLE LINE DIAGRAM (UPDATED)

ELECTRICAL, 480 VOLT AUXILIARY POWER SINGLE LINE DIAGRAM

ELECTRICAL, DC SYSTEM SINGLE LINE DIAGRAM

ELECTRICAL, 125 VOLT DC SCHEMATIC DIAGRAMS SHEET 1

ELECTRICAL, CONNECTION DIAGRAM 125 V D.C. M-G CONTROL

ELECTRICAL, 125 VOLT DC SCHEMATIC DIAGRAMS SHEET 2

ELECTRICAL, DEVICE SCHEDULE SHEET 1

ELECTRICAL, DEVICE SCHEDULE SHEET 2

ELECTRICAL, 480 VOLT AUXILIARY POWER SCHEMATIC DIAGRAMS - SHEET 2

ELECTRICAL, CONNECTION DIAGRAM SHEET 2, GENERATORS NO. 3 AND 4

ELECTRICAL, CONNECTION DIAGRAM SHEET 1, GENERATORS NO. 1 AND 2

ELECTRICAL, CONNECTION DIAGRAM SHEET 6, ACTUATOR

ELECTRICAL, CONNECTION DIAGRAM SHEET 7, 480 VOLT UNIT BOARDS NO. 1-4

ELECTRICAL, CONNECTION DIAGRAM - SHEET 8 - 480 V EQUIPMENT BOARD NO. 1

ELECTRICAL, CONNECTION DIAGRAM - SHEET 9 - 480 V EQUIPMENT BOARD NO. 2

ELECTRICAL, CONNECTION DIAGRAM - SHEET 10 - 480 V EQUIPMENT BOARD NO. 3

ELECTRICAL, CONNECTION DIAGRAM - SHEET 11 - 480 V EQUIPMENT BOARD NO. 4

ELECTRICAL, CONDUIT AND GROUNDING - GENERATOR 1 AREA, EL. 347.0 - PLAN

ELECTRICAL, CONDUIT AND GROUNDING - GENERATOR 2 AREA, EL. 347.0 - PLAN

ELECTRICAL, CONDUIT AND GROUNDING - GENERATOR 3 AREA, EL. 347.0 - PLAN

ELECTRICAL, CONDUIT AND GROUNDING - GENERATOR 4 AREA, EL. 347.0 - PLAN

ELECTRICAL, CONDUIT AND GROUNDING - GENERATOR FLOOR, EL. 347.0 - DETAILS

ELECTRICAL, CONDUIT AND GROUNDING - TURBINE 1 AREA, EL. 331.0 - PLAN

ELECTRICAL, CONDUIT AND GROUNDING - TURBINE 2 AREA, EL. 331.0 - PLAN

ELECTRICAL, CONDUIT AND GROUNDING - TURBINE 3 AREA, EL. 331.0 - PLAN

ELECTRICAL, CONDUIT AND GROUNDING - TURBINE 4 AREA, EL. 331.0 - PLAN

ELECTRICAL, CONDUIT AND GROUNDING - TURBINE FLOOR, EL. 331.0 - DETAILSQ9-79/822.3

Q9-79/821.4

ELECTRICAL, CABLE TRAY ROUTING - KEY PLAN

ELECTRICAL, CABLE TRAY ROUTING - UNIT 1 - PLAN AND SECTIONS

ELECTRICAL, CABLE TRAY ROUTING - UNIT 2 - PLAN AND SECTIONS

ELECTRICAL, CABLE TRAY ROUTING - UNIT 3 - PLAN AND SECTIONS

ELECTRICAL, CABLE TRAY ROUTING - UNIT 4 - PLAN AND SECTIONS

ELECTRICAL, CABLE TRAY ARRANGEMENT - KEY PLAN

ELECTRICAL, CABLE TRAY ARRANGEMENT - SPREAD ROOM WALKWAY

ELECTRICAL, CABLE TRAY ARRANGEMENT - UNIT 1 - PLAN AND SECTIONS

ELECTRICAL, CABLE TRAY ARRANGEMENT - UNIT 2 - PLAN AND SECTIONS

ELECTRICAL, CABLE TRAY ARRANGEMENT - UNIT 3 - PLAN AND SECTIONS

ELECTRICAL, CABLE TRAY ARRANGEMENT - UNIT 4 - PLAN AND SECTIONS

ELECTRICAL, CABLE TRAY ARRANGEMENT - TRAY SUPPORT DETAILS - SHEET 1

ELECTRICAL, CABLE TRAY ARRANGEMENT - TRAY SUPPORT DETAILS - SHEET 2

ELECTRICAL, CABLE TRAY ARRANGEMENT - TRAY SUPPORT DETAILS - SHEET 3

ELECTRICAL, POWERHOUSE GROUNDING - PLANS - EL. 347.0 AND ABOVE

ELECTRICAL, POWERHOUSE GROUNDING - PLANS - EL. 331.0 AND BELOW

ELECTRICAL, LIGHTING CABINET DETAILS

ELECTRICAL, CONNECTION DIAGRAMS LIGHTING CABINETS LC4, LC5, LC6 & LC7

ELECTRICAL, CONNECTION DIAGRAMS LIGHTING CABINETS LC8, LC9, LC10 & LC11

ELECTRICAL, COMMUNICATION DIAGRAM AND SEL-2404 IRIG-B SATELLITE CLOCK

WIRING AND CONDUIT HYDRAULIC TURBINE

CS-28

CS-29

CONDUIT AND CABLE SCHEDULE SHEET CS-28

CONDUIT AND CABLE SCHEDULE SHEET CS-29

CS-28.TIF

CS-29.TIF

CS-30 CS-30.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-30

ELECTRICAL, CONN. DIAGRAM - SHEET 12 - 480 V EQUIPMENT BOARD NO. 5 AND 6

CS-31 CS-31.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-31

36C735228 36C735228.TIF (OUTLINE) AMPLIDYNE MOT GEN SET

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/2

/2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

G-002SHEET NAME:G2hdcbpe Bill P. ElamBY USERNAME:DATE AND TIME PLOTTED: 8/27/2015 3:56:07 PM

SHEET

DRAWING NUMBER TITLESHEET NUMBER

INDEX OF DRAWINGS

233E800

0114r0277 SHT 1

0114r0277 SHT 2

0114r0277 SHT 3

0114r0277 SHT 4

0114r0277 SHT 5

109C7659

117B6365

128B9072

44B200182

44B200184

553E836

44C201171 SHT 1

44C201171 SHT 2

553E835

44C201166

44D200362

44D200386

44D200388

44D200391

553E837

553E849

553E916

638C605

718E246

718E248

718E279 SHT 1

718E335

718E561

723D153

725D939

725D940

726E135

718E279 SHT 2

ELEMENTARY DIAGRAM

GEN. VOLTAGE REGULATOR CIRCUITS

EXCITER & D.C. CONTROL CIRCUITS

OIL HEAD CONNECTIONS

MOTOR OPERATED FIELD RHEOSTAT

DIAGRAM OF CONNECTIONS

ARRANGEMENT OF MAIN & NEUTRAL LEADS

VOLTAGE ADJUSTER PANEL

A.C. SUPPLY PANEL

TRANSFER CONTACTOR PANEL

D.C. CONTROL PANEL

D.C. CONTROL PANEL

LIMIT AMPLIFIER PANEL

VOLTAGE REGULATOR

REACTIVE AMPERE LIMIT PANEL

AMPLIFIER PANEL

AIR COOLER PIPING

PIPING PLAN

TERMINAL BOARD ARRANGEMENT

BRAKE & JACK PIPING

OUTLINE HYDRAULIC TURBINE DRIVEN GENERATOR

SURFACE AIR COOLER (OUTLINE)

GRILLE (FOR MAIN & NEUTRAL LEADS)

COVER PLATES (LOWER)

INSTRUMENTS & ACCESSORIES CONDUIT CONNECTIONS

INSTRUMENTS & ACCESSORIES CONDUIT CONNECTIONS

ASSEMBLY OF CONNECTIONS

ENCLOESD SWITCHGEAR

ENCLOSED SWITCHGEAR CONNECTION DIAGRAM

ENCLOSED SWITCHGEAR CONNECTION DIAGRAM

ASSEMBLY HYDRAULIC TURBINE DRIVEN GENERATOR

S T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

R

H E

R N

A N

D E

Z

IN

D

E X O

F D

R A

W

IN

G S

718E279 - PARTS INSTRUMENTS & ACCESSORIES CONDUIT CONNECTIONS- PARTS LIST

B P

P -1 .0

G -0

X X

X .d g n

G-003

S H

E E

T O

F

GENERAL REFERENCE DRAWINGS

CS-33 CS-33.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-33

CS-34 CS-34.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-34

CS-35 CS-35.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-35

CS-36 CS-36.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-36

CS-37 CS-37.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-37

CS-38 CS-38.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-38

CS-39 CS-39.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-39

CS-40 CS-40.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-40

CS-41 CS-41.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-41

CS-42 CS-42.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-42

CS-43 CS-43.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-43

CS-44 CS-44.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-44

CS-45 CS-45.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-45

CS-46 CS-46.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-46

CS-47 CS-47.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-47

CS-48 CS-48.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-48

CS-49 CS-49.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-49

CS-50 CS-50.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-50

CS-51 CS-51.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-51

CS-52 CS-52.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-52

CS-53 CS-53.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-53

CS-54 CS-54.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-54

CS-55 CS-55.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-55

CS-56 CS-56.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-56

CS-57 CS-57.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-57

CS-58 CS-58.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-58

CS-59 CS-59.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-59

CS-60 CS-60.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-60

CS-61 CS-61.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-61

CS-62 CS-62.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-62

CS-63 CS-63.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-63

CS-64 CS-64.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-64

CS-65 CS-65.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-65

CS-66 CS-66.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-66

CS-67 CS-67.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-67

CS-68 CS-68.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-68

CS-69 CS-69.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-69

CS-70 CS-70.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-70

CS-71 CS-71.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-71

CS-72 CS-72.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-72

CS-73 CS-73.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-73

CS-74 CS-74.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-74

CS-75 CS-75.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-75

CS-76 CS-76.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-76

CS-77 CS-77.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-77

CS-78 CS-78.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-78

CS-79 CS-79.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-79

CS-80 CS-80.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-80

CS-81 CS-81.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-81

CS-82 CS-82.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-82

CS-83 CS-83.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-83

CS-84 CS-84.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-84

CS-85 CS-85.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-85

CS-86 CS-86.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-86

CS-87 CS-87.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-87

CS-88 CS-88.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-88

CS-89 CS-89.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-89

CS-90 CS-90.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-90

CS-91 CS-91.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-91

CS-92 CS-92.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-92

CS-93 CS-93.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-93

CS-94 CS-94.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-94

CS-95 CS-95.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-95

CS-96 CS-96.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-96

CS-97 CS-97.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-97

CS-98 CS-98.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-98

CS-99 CS-99.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-99

CS-100 CS-100.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-100

CS-101 CS-101.TIF

CS-103 CS-103.TIF

CS-104 CS-104.TIF

CS-105 CS-105.TIF

CS-106 CS-106.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-106

CONDUIT AND CABLE SCHEDULE SHEET CS-101

CONDUIT AND CABLE SCHEDULE SHEET CS-103

CONDUIT AND CABLE SCHEDULE SHEET CS-104

CONDUIT AND CABLE SCHEDULE SHEET CS-105

GENERAL ELECTRIC CO. - REFERENCE DRAWINGS

0115R0602 SHT 2

0115R0602 SHT 3

0115R0603 SHT 1

0115R0603 SHT 2

0114r0277-SHT-1.TIF

0114r0277-SHT-2.TIF

0114r0277-SHT-3.TIF

0114r0277-SHT-4.TIF

0114r0277-SHT-5.TIF

0115R0602 SHT 1

REACTIVE AMPERE LIMIT & LIMIT AMPLIFIER CIRCUITS

INDICATION, BKR CONT, LT & RE CKT

0115R0602 GEN 4 PNL 1F.DGN

0115R0602 ... SHT 2.DGN

0115R0602 ... SHT 3.DGN

CONNECTION DIAGRAM BARKLEY POWER PLANT GEN. NO.4

CONNECTION DIAGRAM BARKLEY POWER PLANT GEN. NO.4 & BUS 1 BREAK-UP REL

CONNECTION DIAGRAM BARKLEY POWER PLANT GEN.NO.4 & BUS 1 BREAK-UP

0115R0603 SHT 3

0115R0605 SHT 1

0115R0605 SHT 2

0115R0605 SHT 3

0115R0606 SHT 1

0115R0606 SHT 2

0115R0606 SHT 3

0115R0647 SHT 1

0115R0647 SHT 2

GENERATOR NO.3 PNL 2F, SHEET 1

GEN. NO.2 PNL 4F, SHEET 1

0115R0603 ... SHT-1.DGN

0115R0603 ... SHT-2.DGN

0115R0603 ... SHT-3.DGN

0115R0605 ... SHT-1.DGN

0115R0605 ... SHT-2.DGN

0115R0605 ... SHT-3.DGN GEN. NO.2 & BUS 2 BK-UP REL UNIT 4, SHEET 3

0115R0606 ... SHEET 1.DGN

0115R0606 ... SHEET 2.DGN

0115R0606 ... SHEET 3.DGN

GEN. NO.1 PNL 5F, SHEET 1

GEN. NO.1 & MAIN TRANSFORMER 1 UNIT 5, SHEET 2

GEN. NO.1 & MAIN TRANSFORMER 1 UNIT 5, SHEET 3

0115R0647SHT1.TIF

BARKLEY POWER PLANT RECORDING BOARD UNIT 1, SHEET 2

BARKLEY POWER PLANT RECORDING BOARD UNIT 1, SHEET 1

0115R0647SHT2.TIF

0115R0648 SHT 2

0115R0648 SHT 1 0115R0648SHT1.TIF

0115R0648SHT2.TIF

BARKLEY POWER PLANT RECORDING BOARD UNIT 2, SHEET 1

BARKLEY POWER PLANT RECORDING BOARD UNIT 2, SHEET 2

0115R0649 0115R0649.TIF

0115R0651 0115R0651.TIF

0115R0651A 0115R0651A.TIF

BARKLEY POWER PLANT RECORDING BOARD GEN.4, UNIT 3

BARKLEY POWR PLANT RECORDING BOARD GEN. 2, UNIT 5

BARKLEY POWER PLANT RECORDING BOARD GEN. 2, UNIT 5

0115R0652 0115R0652.TIF

0115R0652A 0115R0652A.TIF

BARKLEY POWER PLANT RECORDING BOARD GEN. 1, UNIT 6

BARKLEY POWER PLANT RECORDING BOARD GEN. 1, UNIT 6

0115R0652B 0115R0652B.TIF BARKLEY POWER PLANT OSCILLOGRAPH RECORDING BOARD, UNIT 7

100519-400E 100519-400E.TIF

100519-404D 100519-404D.TIF

100519-450E 100519-450E.TIF

PANALARM WIRING DIAGRAM OF ANN. REL. CUBICLE, GROUPS A, B, D & E

PANALARM FIELD WIRING TO ANN. REL. CUBICLE, GROUPS A THROUGH H

PANALARM SCHEMATIC DIAGRAM

0115R0638 BARKLEY POWER PLANT BATT BOARD- 125V D.C. DISTRIBUTION, UNIT 2

ROTOR CONNS & ACCESS

CONNECTION DIAGRAM GEN NO.1 & MAIN TRANSFORMER 2 UNIT 2, SHEET 3

CONNECTION DIAGRAM GEN. NO.3 & MAIN TRANSFORMER 2 UNIT 2, SHEET 2

GEN. NO.2 & BUS 2 BK-UP REL UNIT AR, SHEET 2

CS-61A CS-61A.TIF

CS-61B CS-61B.TIF

CONDUIT AND CABLE SCHEDULE SHEET CS-61A

CONDUIT AND CABLE SCHEDULE SHEET CS-61B

CS-95A CS-95A.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-95A

CONDUIT AND CABLE SCHEDULE SHEET CS-104ACS-104A CS-104A.TIF

0115R0638.TIF

759D959 EXCITER LIGHTING

FIO-003 (NEC) GENERATOR AIR COOLER PIPING DIAGRAM

CS-102 CS-102.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-102CS-32 CS-32.TIF CONDUIT AND CABLE SCHEDULE SHEET CS-32

GENDIFFCKT.JPG BAR-P GENERATOR DIFFERENTIAL CIRCUIT (uNITS 2 AND 4)

834C573 ENCLOSED SWITCHGEAR

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/2

/2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

G-003SHEET NAME:G2hdcbpe Bill P. ElamBY USERNAME:DATE AND TIME PLOTTED: 8/27/2015 3:56:17 PM

SHEET

DRAWING NUMBER TITLESHEET NUMBER

INDEX OF DRAWINGS

836C625

887D147

887D839

ENCLOSED SWITCHGEAR

STAIRWAY & PLATFORM

CO2 FIRE EXTINGUISHER PIPING

S T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

R

H E

R N

A N

D E

Z

IN

D

E X O

F D

R A

W

IN

G S

B P

P -1 .0

G -0

X X

X .d g n

G-004

S H

E E

T O

F

GENERAL ELECTRIC CO. - REFERENCE DRAWINGS

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/2

/2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

G-004SHEET NAME:G2hdcbpe Bill P. ElamBY USERNAME:DATE AND TIME PLOTTED: 8/27/2015 3:56:28 PM

P -1 .0

G -0

X X

X .d g n

D U

R

IN

G C

O N

S T

R U

C T

IO

N

A R

E A A

V A

IL

A B

L E T

O C

O N

T R

A C

T O

R S

G-005

S T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

MAIN ENTRANCE

NOTES:

AREA AVAILABLE FOR CONTRACTOR USE DURING CONSTRUCTION

AERIAL VIEW OF BARKLEY DAM

SCALE: NONE

SCALE: NONE

AERIAL VIEW SHOWING POWERHOUSE AND SPILLWAY

R

H E

R N

A N

D E

Z

DETAIL A

SEE DETAIL A

SEE DETAIL A

3. IMAGES FROM GOOGLE MAPS (07 APR. 2015)

UTILITIES MUST BE PROVIDED BY CONTRACTOR.

BARKLEY PROJECT. SANITATION, STEP-DOWN TRANSFORMER(S), AND ANY OTHER

BARKLEY POWERHOUSE PERSONNEL. 480 VAC AND TELEPHONE ARE AVAILABLE FROM

USE. COORDINATION OF EXACT LOCATION WITHIN THIS REGION MUST BE DONE WITH

2. DOTTED LINES IN DETAIL A ENCOMPASS THE AREA AVAILABLE FOR CONTRACTORS

1. POINT 'A' IN AERIAL VIEWS REPRESENTS THE SAME POINTS AND PERSPECTIVE.

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/2

/2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

G-005SHEET NAME:G2hdcbpe Bill P. ElamBY USERNAME:DATE AND TIME PLOTTED: 8/27/2015 3:56:38 PM

P -1 .0

E

D

X X

X .d g n

3-4000-5Y

1-2000-5

-1

-5

Y

5C2

2-14,400-120V

22P2

2-14,400-120V

22P1

59R2

59R2X

TEST RECPT. IN ACT.

TO STA. LOAD

CON. EQUIP.

TO STA. LOAD

RECORDER

3-2000-5Y

2-2000-5

AR

R

R

TR

X

ANN

EXC PMG

V A

A

SI

SI

R V

AR

6A

PL

LDC CCC

R WAS

A

1 1

TCTC

VAR

TB

51G2

ANN

30A

V

VS

C

A

B

GOV

MOT

GEN.2

36,111KVA

.90PF,13.8KV

3 ,60

1200A, 13.8KV

250MVA

"JEMSTAR"

M

TB

ANNUNCITOR

OPERATES:

EXCITER FIELD REDUCING CONTACTOR

EXCITER FIELD RHEOST CONTROL

1-2000-5 (B )

TRIPS & LOCKS OUT:

S T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

GOV. SHUTDOWN SOLENOID

GEN. MAIN ACB 228

ANNUNCIATOR

NOTES:

SS

REFERENCE DRAWINGS:

TITLE:

Q9-79/750.23 MAIN SINGLE LINE DIAGRAM

VOL REG

RES

DISCH

DRAWING NUMBER:

G

EXC. FIELD ACB

ED101

E Q

U

IP

M E

N T R

E M

O V

A L

O N

E L

IN

E D

IA

G R

A M

Q9-79/764.11

NO.1 AND NO.2

CONNECTION DIAGRAM SHEET 1, GENERATORS

Q9-79/765.9

NO.3 AND NO.4

CONNECTION DIAGRAM SHEET 2, GENERATORS

R

H E

R N

A N

D E

Z

Q9-79/750.24 MAIN SINGLE LINE DIAGRAM (UPDATED)

DISCONNECT

NEUTRAL

VOLTMETER

VARMETER

WATTMETER

AMMETER

PILOT LIGHT

SPEED INDICATOR

SYNCHRONIZING SWITCH

GROUND DETECTOR RELAY

DIFFERENTIAL RELAY

TEST OR TRANSFER BLOCK

POTENTIAL CIRCUIT

POTENTIAL POLARIZING CIRCUIT

CURRENT CIRCUIT

A

W

V

VAR

PL

SI

SS

R

V

RX

TB

S STATUS MONITORED BY SCADA

USACE SYMBOLSIEEE SYMBOLS

ROTOR SHAFT

PERMANENT MAGNET GENERATORPMG

LEGEND:

045 UNIT 4

035 UNIT 3

015 UNIT 1

4. NEUTRAL DISCONNECT SWITCH FOR OTHER UNITS:

3. UNIT 2 SHOWN OTHER UNITS SIMILAR.

2. DETAILS REMOVED FOR CLARITY.

1. BOLD AND HATCHED ITEMS INDICATE EQUIPMENT TO BE REMOVED.

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/9 /2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

ED101SHEET NAME:g2hdcbbm Bijan MasoumpanahBY USERNAME:DATE AND TIME PLOTTED: 6/9/2016 1:25:31 PM

NOTES:

T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

SCALE: 3/16=1'-0"

ELEVATION A-A

GEN. MAIN VCB

GEN. MAIN VCB GEN. MAIN VCB

GEN. MAIN VCB

GEN. HRG LOAD & ACCESSORIES

GEN. HRG TRANS. & DISC.

GEN. HRG LOAD & ACCESSORIES

GEN. HRG TRANS. & DISC.

POTHEAD CUBICLE

GEN. MAIN VCB

GEN. MAIN VCB

TRANSF. ACB

STATION SERVICE

POTHEAD CUBICLE

COMPT.

TRANSF. NO.1

STATION SERVICE

Q9-79/841

9" CABLE TRAY

& SURGE COMPT.

INST. TRANSF.

EL. 366.0

G

-2

T

13 12

G

-3

T

EL. 347.0

UNIT BD. NO.2

EL. 331.0

UNIT BD. NO.1

CONTR. JT.

SURGE COMPT.

INSTR. TRANSF. &

G

-2

T

G

-3

T

UNIT NO.1

C O

N T

R J T

Z

G

J

C O

N T

R J T

C GEN. LEADS BUS DUCT BELOWL

POTHEAD CUBICLE

BD. 2

480V. EQUIP.

FAN ROOM 4

DN

LTG. TRANSF. NO.1

10 116 7 8 9

5'-1"

Y

X

UNIT NO.2

C O

N T

R J T

C GEN. LEADS BUS DUCT BELOWL

POTHEAD CUBICLE

5'-1"

12 13 14 15 16

STA. SERV. TRANSF. NO.1 ACB

NO.2

LTG. TRANSF.

480V. MAIN AUX. BOARD

TRANSF. NO. 1

STA. SERVICE

TRANSF. NO. 2

STA. SERVICE

UNIT NO.3

C O

N T

R J T

C GEN. LEADS BUS DUCT BELOWL

POTHEAD CUBICLE

5'-1"

STA. SERV. TRANSF. NO.2 ACB

17 18 19 20 21

DN

CO EQUIPMENT

UNIT NO.4

C GEN. LEADS BUS DUCT BELOWL

POTHEAD CUBICLE

BD. 1

480V. EQUIP.

FAN ROOM 5

5'-1"

22 23 24 25

FAN ROOM 6

11 10 9 8 7 6

AA

PLAN EL. 347.0

E Q

U

IP

M E

N T B

E

IN

G R

E M

O V

E D

B P

P -1 .0

E

D

X X

X .d g n

ED201

REFERENCE DRAWINGS:

TITLE:DRAWING NO.

Q9-79/115.1

PLAN - EL. 347.0.

ARCHITECTURAL, UNITS 3 & 4, GENERATOR FLOOR

FINISHED FLOOR

SCALE: NONE

M-G SET

VOL. REG.

M-G SET

VOL. REG.M-G SET

VOL. REG.

M-G SET

VOL. REG.

O N G

E N

E R

A T

O R F

L O

O R

R

H A

N D

E R

D E

Z

STRUCTURAL SLAB

SCALE: 3/16=1'-0"

TOPPER

ARCHITECTURAL

03 60 00. 01.

48 19 26 AND SEC.

AS SPECIFIED IN SEC.

STEEL FOUNDATIONS

REMOVE CHANNEL

EQUIPMENT

EXCITATION

EXISTING

EQUIPMENT

EXCITATION

EXISTING

EQUIPMENT

EXCITATION

EXISTING

EQUIPMENT

EXCITATION

EXISTING

EQUIPMENT

EXISTING EXCITATION

EQUIPMENT

EXISTING EXCITATION

FOUNDATION CHANNEL

EQUIPMENT BASE

Q9-79/704.3 115 KV SWITCHGEAR ARRANGEMENT SHEET 1

TO BE REMOVED (EL.347.0)

DETAIL - EXCITATION EQUIPMENT BASES

SEE NOTE 4

4. DO NOT DAMAGE GROUNDING CABLES UPON EQUIPMENT BASE REMOVAL.

3. REPAIR ANY DAMAGED PAVER TILE TO MATCH EXISTING.

2. RE-SURFACE CONCRETE TO MATCH EXISTING.

1. BOLD AND HATCHED ITEMS INDICATE EQUIPMENT BEING REMOVED.

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/2

/2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

ED201SHEET NAME:G2hdcbpe Bill P. ElamBY USERNAME:DATE AND TIME PLOTTED: 8/27/2015 3:57:13 PM

P -1 .0

E

D

X X

X .d g n

S T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

NOTES:

REFERENCE DRAWINGS:

DRAWING NUMBER TITLE:

726E135

SCALE: NONE

R E

M O

V A

L

E X

IS

T

IN

G E

X C

IT

A T

IO

N S

Y S

T E

M

ED301

SEE NOTE 2

GENERATOR

ASSEMBLY HYDRAULIC TURBINE DRIVEN

PARTIAL SECTION OF HYDRAULIC GENERATOR

R

H E

R N

A N

D E

Z

718E278

CONNECTIONS.

INSTRUMENTS & ACCESSORIES CONDUIT

SEE DETAIL "A"

RIGGING BEING REMOVED.

COMMUTATOR BRUSH

DETAIL "A"

TO BRUSH RIGGING BEING REMOVED.

DC LEADS FROM COMMUTATOR

REMOVE ALL FIELD POLES

DEBRIS, SEE E-302

FROM CONSTRUCTION

PROTECT GENERATOR

TO ROUT DC BUS.

GRILLE COVER

GENERATOR LEAD

MODIFY

3. FILL HOLES REMAINING AFTER FIELD POLE REMOVAL AS SPECIFIED.

& CONDUIT IN GENERATOR HOUSING.

2. REMOVE ALL EXISTING EXCITATION SYSTEM - RELATED CABLE

1. BOLD HATCHED ITEMS INDICATE EQUIPMENT TO BE REMOVED.

DEBRIS, SEE E-302 AND E-303.

PROTECT GENERATOR FROM CONSTRUCTION

MODIFY PLATE TO ROUT DC BUS.

COLLECTOR RING SHALL BE INSPECTED.

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/1 /2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

ED301SHEET NAME:g2hdcsms Scott SutherlandBY USERNAME:DATE AND TIME PLOTTED: 7/1/2016 9:01:33 AM

T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

7U

BLANK

9799X

SEL-2506

FUSE PANEL

13A1 - 13A15

9821/67GA

SEL-311C

13TB5B13TB5A 13TB5C

13TB6B13TB6A 13TB6C

9899X

4U

13TB4B13TB4A 13TB4C

9886BF

5U

13TB3B13TB3A 13TB3C

86B2

9486BF

43BL87B2

87ST

51ST

S

T

87ST

51ST

87ST 87ST

51ST 51ST

S

T

87ST 87ST

51ST 51ST

PANEL 13

LIVINGSTON LINE

PANEL 12

HOPKINS CO. LINE

PANEL 11

HOPKINSVILLE LINE

PANEL 10

LINE NO.2

KENTUCKY DAM

PANEL 9

SPARE RELAYS (LONG LINES)

& BUS 2 DIFFERENTIAL

PANEL 8

LINE NO.1

KENTUCKY DAM

PANEL 7

STATION GRD. BACK-UP

BUS 1 DIFFERENTIAL &

SPARE RELAYS (SHORT LINES),

PANEL 5

MAIN TRANSFORMER 1

GENERATOR 1 &

PANEL 4

BUS 2 BREAK-UP RELAYS

GENERATOR 2 &

TRANSFORMERS

STATION SERVICE

PANEL 2

MAIN TRANSFORMER 2

GENERATOR 3 &

PANEL 1

BUS 1 BREAK-UP RELAYS

GENERATOR 4 &

6'-0"

9'-2"

2'-11" 3"

/2

INSTRUMENT BOARD

BENCHBOARD

B A

T T

E R

Y B

O A

R D

FUTURE

BENCHBOARD

TABLE

INSTRUMENT BOARD

RELAY BOARD

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

DESK

OPERATOR'S

CONTROL ROOM

R E

C O

R D

IN

G B

O A

R D

IN

S

T R

U M

E N

T R

O O

M C

H A

R T R

O O

M

H

I 2 3 4 5

4" 4"13 PANELS @ 2'-4"=30'-4"

31'-0"

PANEL 3

1"

MEC

MEC MEC

MEC

ASEA RELAY PACKAGE

MHBR

"FT-19R"

"REL-512"

"FT-19R"

DETAIL

SEE

A

"FT-19R"

"SEL-421"

4 3/4"

BLANK

"SEL-351"

MUT

MHAK

MJPD 5

"LOR""SB-1" "SB-1""LOR"

MPZC MPZC

29A1 29B1

B

SEE

DETAIL

MSQ

MUAF

FUA

FUB

FUC

MCBRM

MCBRM

MCBRM

94BF

96TT

MHCAE

OR

43CP

"SB-1"

OAKWOOD LINE

"AMMX"

MHALMHAL

MHBF

MHBF

MJPB

9821/67GB

SEL-321

SEL-351

9121/67GB

9121/67GA

9221/67GB

9221/67GA

64B

SEL-501

9321/67GB

9321/67GA

SEL-311L

9521/67GB

9521/67GA

87B2

SEL-587Z

9421/67GA

9421/67GB

64A

87B1

9721/67GA

9721/67GB

6U

FUSE PANEL

13B1 - 13B15

9186BF

12TB3B12TB3A 12TB3C

12TB4B12TB4A 12TB4C

12TB5B12TB5A 12TB5C

12TB6B12TB6A 12TB6C

9286BF

11TB3B11TB3A 11TB3C

11TB4B11TB4A 11TB4C

11TB5B11TB5A 11TB5C

11TB6B11TB6A 11TB6C

9386BF

86S64B

10TB3B10TB3A 10TB3C

10TB4B10TB4A 10TB4C

10TB5B10TB5A 10TB5C

10TB6B10TB6A 10TB6C

10TB7B10TB7A 10TB7C

9TB4B9TB4A 9TB4C

9TB5B9TB5A 9TB5C

9TB6B9TB6A 9TB6C

9TB7B9TB7A 9TB7C

8TB4B8TB4A 8TB4C

8TB5B8TB5A 8TB5C

8TB6B8TB6A 8TB6C

9586BF

86S64A

6TB3B6TB3A 6TB3C

8TB7B8TB7A 8TB7C

6TB4B6TB4A 6TB4C

6TB5B6TB5A 6TB5C

6TB6B6TB6A 6TB6C

6TB7B6TB7A 6TB7C

9786BF

86B1 43BL87B1

6TB8A 6TB8C

PANEL 6

9199X

12TB7A

9299X

9399X

9599X

8TB3B8TB3A 8TB3C9TB3B9TB3A 9TB3C

9499X

9TB8A

1U BLANK

FUSE PANEL

6A1 - 6A15

FUSE PANEL

6B1 - 6B15

FUSE PANEL

8A1 - 8A15

FUSE PANEL

8B1 - 8B15

FUSE PANEL

9A1 - 9A15

FUSE PANEL

9B1 - 9B15

FUSE PANEL

10A1 - 10A15

FUSE PANEL

10B1 - 10B15

FUSE PANEL

11A1 - 11A15

FUSE PANEL

11B1 - 11B15

FUSE PANEL

12A1 - 12A15

FUSE PANEL

12B1 - 12B15

SEL-2032

3U

KEY PLAN

END ELEVATION

RELAY BOARD ELEVATION

9629C

9621/67GB

9629B

9621/67GA

9629A

PB

BL1

4UR

"SEL-587"

"SEL-300G"

TB46

TB42

TB43

TB38

TB39

TB38A TB38B TB38C

TB39A TB39B TB39C

TB42A TB42B TB42C

TB42D TB42E TB42F

59RX

T

PR

PB

SEL-387

SEL-

4UR

"SEL-587"

"SEL-300G"

TB30

TB31

TB34

TB35

TB34A TB34B TB34C

TB35A TB35B TB35C

TB30A TB30B TB30C

TB30D TB30E TB30F

T

PR

PB

SEL-387

SEL-

4UR

"SEL-587"

"SEL-300G"

TB7

TB36

TB37

TB36A TB36B TB36C

TB37A TB37B TB37C

TB07B TB07C

TB10A TB10B

59RX

SEL-

TB07A

4UR

"SEL-587"

"SEL-300G"

SEL-

TB78

TB32

TB33

TB08A TB08B TB08C

TB09A TB09B

SEL-311C

TB32A TB32B TB32C

TB33A TB33B TB33C

B

X

P

C

SEL-311C

P

C

B

X

C

P

C

P

G

X

G

X

G

X

G

X

GRD

FLD

GRD

FLD

GRD

FLD

GRD

FLD

BOARD

RELAY

R E

L A

Y B

O A

R D M

O D

IF

IC

A T

IO

N S

R E

M O

V A

L

REFERENCE DRAWINGS:

TITLE:

Q9-79/701.10

DRAWING NUMBER:

R

H E

R N

A N

D E

Z

59RX

SCALE: NONE

SCALE: NONE

SCALE: NONE

APRON

SEE NOTE 1SEE NOTE 1

MAIN RELAY BOARD

ED401

B P

P -1 .0

E

D

X X

X .d g n

SEE NOTE 4

59RX

SEE DETAIL "A"

"SEL-587"

GRD

FLD

59RX

SCALE: NONE

RELAYS BEING REMOVED IN BOLD

DETAIL "A"

FOR HMI INSTALL. SEE E-401.

4. ENSURE RECORDING BOARD PANEL THAT WILL BE USED FOR THE HMI IS READY

3. BOLD AND HATCHED ITEMS TO BE REMOVED.

2. ALL UNIT PANELS SIMILAR.

PANEL IN FOUR PLACES

1. REMOVE FIELD GROUND RELAY (64F), OVERVOLTAGE AUX. RELAY (59RX), AND

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/1 /2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

ED401SHEET NAME:g2hdcsms Scott SutherlandBY USERNAME:DATE AND TIME PLOTTED: 7/1/2016 9:01:43 AM

R

M

O V

A L

S T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

BENCHBOARD SCHEDULE

11. MOTOR-OPERATED EXITER FIELD RHEOSTAT CONTROL SWITCH

16. VOLTAGE REGULATOR TRANFER SWITCH

25. VOLTAGE ADJUSTING CONTROL SWITCH

APRON AND INSTRUMENT SCHEDULE

64. AMPLIDYNE INPUT

65. AMPLIDYNE OUTPUT

SYMBOLS

SCALE: NONE

B P

P -1 .0

E

D

X X

X .d g n

9. EXCITER FIELD ACB CONTROL SWITCH

14. UNIT START-STOP CONTROL SWITCH

BLUE INDICATING SWBD. LIGHT

AMBER INDICATING SWBD. LIGHT

GREEN INDICATING SWBD. LIGHT

RED INDICATING SWBD. LIGHT

WHITE INDICATING SWBD. LIGHT

LAMP-10 WATT, 120 VOLT, S14 CLEAR

154 KV. MIMIC BUS, RED FINISH

13.8 KV. MIMIC BUS, LIGHT BLUE FINISH

480 V. MIMIC BUS, BLACK FINISH

66 KV. MIMIC BUS, ORANGE FINISH

AM

FIELD

VM

IND.

SPEED

ADJ.

SPEED

GEN.

54 64

50 77 52 53

27 55

REG.

VOLT

9 25

1. BOLD-HATCHED ITEMS INDICATE EQUIPMENT TO BE REMOVED.

4. DECOMMISIONED

R

H E

R N

A N

D E

Z

REFERENCE DRAWINGS:

Q9-79/700.9

DRAWING NO:

MAIN CONTROL AND INSTRUMENT BOARD

DRAWING TITLE:

SCALE: NONE

SCALE: NONE

SCALE: NONE

WM VMAM

VAR

AM

FIELD

VM

AM

FIELD

VM

AM

FIELD

VM

AM

FIELD

VM

IND.

SPEED

ADJ.

SPEED& POS. IND.

GATE LIMIT

54 64

50 77 57 53

27 55

AM AM

VAR

& POS. IND.

GATE LIMIT

57 68 57

IND.

SPEED

ADJ.

SPEED

GEN.

54 64

50 77 52 53

27 55

GEN.

ANNUNCIATOR A ANNUNCIATOR B

PANEL 1

GENERATOR 4

PANEL 2

GENERATOR 3

PANEL 3

TRANSF. 2 TRANSF. 1

STATION SERVICE

IND.

SPEED

ADJ.

SPEED

VAR

54 64

50 77 52 53

27 55

& POS. IND.

GATE LIMIT

GEN.

ANNUNCIATOR DANNUNCIATOR C

WM

VM

WM

PANEL 4

GENERATOR 2

IND.

SPEED

ADJ.

SPEED

VAR

54 64

50 77 52 53

27 55

& POS. IND.

GATE LIMIT

GEN.

ANNUNCIATOR E

PANEL 5

GENERATOR 1

POT.

CUR.

& POS. IND.

GATE LIMIT

AM AM

VAR

50 58 58 75

PANEL 6

WM

62 66

& SPARE OCB 974

MAIN TRANSFORMER 2

BENCHBOARD

APRON

AM

ANNUNCIATOR F

CLOCK

SATELLITE

SEL 2404

INSTRUMENT BOARD

9 25

PANEL 1

GENERATOR 4

3 15

PANEL 2

GENERATOR 3

1717 12

3 15

PANEL 3

TRANSF. 2 TRANSF. 1

STATION SERVICE

3 15

19 23

PANEL 4

GENERATOR 2

PANEL 5

GENERATOR 1

SECTION 2

154 KV BUS 1

SECTION 2

154 KV BUS 2

PANEL 6

& SPARE OCB 974

MAIN TRANSFORMER 2

AM WM VMAM WM VM AM WM VM AM WM VM

REG.

VOLT

REG.

VOLT

REG.

VOLT

REG.

VOLT

C O

N T

R O

L R

O O

M M

O D

IF

IC

A T

IO

N S

VARVAR

ED402

& POS. IND.

GATE LIMIT

FRONT VIEW DETAIL

BENCHBOARD DETAIL

FRONT VIEW

PARTIAL BENCHBOARD PLAN

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/9 /2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

ED402SHEET NAME:g2hdcbbm Bijan MasoumpanahBY USERNAME:DATE AND TIME PLOTTED: 6/9/2016 1:25:40 PM

P -1 .0

S -1

X X

X .d g n

DRAWING NUMBER TITLE

S-101

S T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

Q9-79/114.1A

PLAN - EL.347.0

ARCHITECTURAL, UNITS 1 AND 2 , GENERATOR FLOOR

Q9-79/115.1

PLAN - EL.347.0

ARCHITECTURAL, UNITS 3 AND 4 , GENERATOR FLOOR

Q9-79/226A.3

ELECTRICAL BAY FLOOR, EL. 347.0 - SHEET 1

STRUCTURAL - CONCRETE OUTLINE, GENERATOR AND

Q9-79/226B.3

ELECTRICAL BAY FLOOR, EL. 347.0 - SHEET 2

STRUCTURAL - CONCRETE OUTLINE, GENERATOR AND

Q9-79/328A.1

AND ELECTRICAL BAY FLOOR, EL.347.0 - SHEET 1

STRUCTURAL - REINFORCEMENT, UNIT BAYS, GENERATOR

Q9-79/328C

Q9-79/813.2

FLOOR, EL.347.0 - DETAILS

ELECTRICAL, CONDUIT AND GROUNDING, GENERATOR

EL.347.00

FINISHED FLOOR

REFERENCE DRAWINGS:

NOTES:

R

H E

R N

A N

D E

Z

PPT

EXC

CLF

2'-0" 4'-0"

BEAM GB-8, 18 X 36

CONTRACTION JT.

FLOW

BEAM GB 43, 36 X 48

g

L C

L C g

38'-3" TO L UNIT

C

OF 18" X 2'-6"

EST. DIMENSION

PENETRATION

NEW AC BUS

14"

20'-6"

1'-6"1'-6"

1'-3"

3'-0"

18 X 36

BEAM GB-8

21 22

24 X 48

BEAM GB-42

9'-4"

CONTRACTION JT.

5'-0"

3'-6"

LEGEND:

EXC DIGITAL EXCITATION SYSTEM

PPT POWER POTENTIAL TRANSFORMER

CLF CURENT LIMITING FUSES

CABLES FROM EL.331.0

EXISTING HOLES ARE USED TO RUN EXCITATION

MAIN UNIT

WORK AREA

OF 14" X 14"

EST. DIMENSION

PENETRATION

NEW DC BUS

12"

CONCRETE

SMOOTH FINISH

PAVER TILE FLOOR

5'-0"

HOLE IN CHANNEL

THREADED ANCHOR BOLT IN

S

T A

L L

CUBICLE

EQUIPMENT

CHANNEL

FOUNDATION

NON SHRINK GROUT

LOCKING WASHERS.

BOLTING. PROVIDE

FOR EQUIPMENT

DRILL AND TAP HOLES

2 1/2"

AND ELECTRICAL BAY FLOOR BEAM ELEVATIONS

STRUCTURAL - REINFORCEMENT, UNIT BAYS, GENERATOR

CHANNEL

FOUNDATION

TYP

TYPICAL DIMENSIONS FOR OTHER UNITS

BEAM GB-32, 18 X 36 (UNIT 1)

TYPICAL DIMENSIONS FOR OTHER UNITS

BEAM GB-32, 18 X 36 (UNIT 1)

TYP

TO MISS REBAR

ANCHOR HOLESTO SUIT

GROUT HOLES

HOLES TO SUIT

EQUIPMENT MOUNTING

2 1/2"

4" MIN.

C O

N C

R E

T E M

O D

IF

IC

A T

O N

S A

N D

S U

G G

E S

T E

D E

Q U

IP

M E

N T L

A Y

O U

T

BEAM GB-36, 18 X 24

2"

10"

AS SPECIFIED.

OF STRUCTURAL BEAM,

CORE DRILL ON THIS SIDE

EQUIPMENT AS SPECIFIED.

12. MAINTAIN WORKING AND ARC-FLASH CLEARANCES ON NEW AND EXISTING

SECONDARY REINFORCING IF PRACTICABLE.

15" ON CENTER BOTH TOP AND BOTTOM FACE. AVOID DAMAGE TO PRIMARY AND

PLACED PARALLEL TO GB-32 AND GB-36 IS SECONDARY REINFORCING AND IS SPACED

AND IS SPACED 15" ON CENTER BOTH TOP AND BOTTOM FACE. REINFORCING

11. REINFORCING PLACED PARALLEL TO GB-42 AND GB-43 IS PRIMARY REINFORCING

TO COLUMNS, BEAMS, OR GROUND SYSTEM.

10. WHEN PERFORMING CONCRETE REMOVAL, NO DAMAGE IS PERMITTED

9. ENSURE ACCESS TO EQUIPMENT IS CONVENIENT FOR OPERATION AND MAINTENANCE.

PERSONNEL TO WALK NEAR THE ENCLOSURE ON EL. 347.0.

8. ENCLOSE BUSWORK IN ONE MAIN ENCLOSURE TO ENSURE SAFE CLEARANCE FOR

7. BOLD ITEMS INDICATE NEW EQUIPMENT.

CONSTRUCTION.

6. REPAIR FLOORING TO MATCH EXISTING IF DAMAGED DURING

5. EQUIPMENT MOUNTING HOLES TO SUIT CUBICLE PROVIDED.

4. ANCHOR LOCATIONS SHALL BE ADJUSTED TO MISS REINFORCING.

OF ARCHITECTURAL TOP SLAB REINFORCING.

3. CONTRACTOR MAY HAVE TO IMAGE SLAB FROM UNDERNEATH BECAUSE

2. DO NOT CORE DRILL WITHIN 6" OF BEAMS OR COLUMNS.

1. DIMENSIONS ARE APPROXIMATE. SEE REFERENCE DRAWINGS FOR DETAILS.

SCALE: 3/4" = 1' -0"

SECTION A-ASCALE: 1/2" = 1' -0"

PARTIAL PLAN VIEW OF EL.347.0

SCALE: NONE

KEY PLAN

SCALE: NONE

EQUIPMENT ANCHORING DETAIL

SCALE: NONE

FOUNDATION CHANNEL LAYOUT SCALE: NONE

EQUIPMENT MOUNTING DETAIL

S-101

A

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/2

/2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

S-101SHEET NAME:G2hdcbpe Bill P. ElamBY USERNAME:DATE AND TIME PLOTTED: 8/27/2015 3:58:02 PM

P -1 .0

S -1

X X

X .d g n

NOTES:

S-102

S T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

LEGEND:

REFERENCE DRAWINGS:

DRAWING NUMBER TITLE

Q9-79/225A.1

Q9-79/225B.2

Q9-79/225C.1 STRUCTURAL - CONCRETE OUTLINE, SPIRAL CASE-ROOF SHEET 3

Q9-79/225D.3

GENERATOR BARREL

EL.346.83

EL.342.54

EL.336.92

EL.333.33

VIEWPOINT

IMAGE 'B'

VIEWPOINT

IMAGE 'A'

(IMAGE 'A')

DOOR SEE

CEILING

VIEWPOINT

IMAGE 'B'

VIEWPOINT

IMAGE 'A'

DOOR

LEGEND:

IMAGE 'A'

IMAGE 'B'

2'-9"2'-9"

4"

1'-6"

Q9-79/226A.3

EL.347.0 - SHEET 1

STRUCTURAL - UNIT BAYS, GENERATOR & ELECTRICAL BAY FLOOR

Q9-79/226B.3

EL.347.0 - SHEET 2

STRUCTURAL - UNIT BAYS, GENERATOR & ELECTRICAL BAY FLOOR

D C B

U S C

O N

C R

E T

E P

E N

E T

R A

T

IO

N

R

H E

R N

A N

D E

Z

PROPOSED LOCATION OF DC BUS.

14" 1'-7"

1'-2"

14" X 14" MAXIMUM PENETRATION

NEW DC BUS PENETRATION

PROPOSED LOCATION OF

PENETRATION

EXISTING AC BUS

PENETRATION

OF NEW DC BUS

PROPOSED LOCATION

PENETRATION

EXISTING DOOR

PENETRATION

EXISTING AC BUS

PENETRATION

FOR NEW DC BUS

PROPOSED LOCATION

PENETRATION

FOR NEW BUS

PROPOSED LOCATION

BUS CONCRETE PENETRATION.

AREA INSIDE OF THIS REGION AVAILABLE FOR THE NEW DC

L UNITC

BUS PENETRATION

EXISTING AC

PENETRATION

NEW DC BUS

APPROX. 12"

IN CORNERS

DO NOT OVERCUT

WITH 2" DIA. HOLES.

CORE DRILL CORNERS

14"

5" MIN.

14"

SHEET 1

STRUCTURAL - CONCRETE OUTLINE, UNIT BAYS, SPIRAL CASE-ROOF

SHEET 2

STRUCTURAL - CONCRETE OUTLINE, UNIT BAYS, SPIRAL CASE-ROOF

CASE-ROOF SHEET 4

STRUCTURAL - CONCRETE OUTLINE, UNIT BAYS, SPIRAL

IN

S

T A

L L

R E

G

IO

N E

L .3

.0

4. DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO VERIFY.

UL 1479.

BE SEALED TO PROVIDE A 2 HOUR FIRE RESISTIVE RATING IN ACCORDANCE WITH

3. ALL BUS PENETRATIONS THROUGH STRUCTURAL CONCRETE OR STEEL SHALL

A MINIMUM OF 5 INCHES.

2. LEAVE AS MUCH SPACE AS POSSIBLE BETWEEN THE AC AND DC BUS, WITH

DASHED LINES ON GENERATOR BARREL (SHOWN ON VIEW B-B).

1. PRIOR APPROVAL IS REQUIRED TO PENETRATE CONCRETE BEYOND

SCALE: 3/4" = 1' -0"

DC BUS BORE REGION

SECTION A-A

SCALE: 3/4" = 1' -0"

VIEW B-B SCALE: 3" = 1' -0"

TYPICAL PENETRATION DETAIL

SCALE: 3/16" = 1' -0"

PARTIAL PLAN OF CONCRETE PENETRATIONS

S-102

A

S-102

B

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/2

/2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

S-102SHEET NAME:G2hdcbpe Bill P. ElamBY USERNAME:DATE AND TIME PLOTTED: 8/27/2015 3:58:15 PM

P -1 .0

E -1

X X

X .d g n

1-2000-5

-1

-5

Y

87G2

87G2X

5C2

22P2

TEST RECPT. IN ACT.

AR

R

R

TR

AR

X

64G2

X

ANN

6A

PL

TB

30A

V

VS

C

A

B

GEN.2

36,111KVA

.90PF,13.8KV

3 ,60

1200A, 13.8KV

250MVA

TB

TRIPS & LOCKS OUT:

GOV. SHUTDOWN SOLENOID

GEN. MAIN ACB 228

ANNUNCIATOR

NOTES:

E-101

S T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

REFERENCE DRAWINGS:

VOLTMETER

VARMETER

WATTMETER

AMMETER

PILOT LIGHT

SPEED INDICATOR

SYNCHRONIZING SWITCH

GROUND DETECTOR RELAY

DIFFERENTIAL RELAY

TEST OR TRANSFER BLOCK

POTENTIAL CIRCUIT

POTENTIAL POLARIZING CIRCUIT

CURRENT CIRCUIT

A

W

V

VAR

PL

SI

SS

R

V

RX

TB

S STATUS MONITORED BY SCADA

IEEE SYMBOLS

ROTOR SHAFT

G

EXC. FIELD ACB

TITLE:

Q9-79/750.23 MAIN SINGLE LINE DIAGRAM

DRAWING NUMBER:

Q9-79/764.11

NO.1 AND NO.2

CONNECTION DIAGRAM SHEET 1, GENERATORS

Q9-79/765.9

NO.3 AND NO.4

CONNECTION DIAGRAM SHEET 2, GENERATORS

E Q

U

IP

M E

N T I

N S

T A

L L

O N

E L

IN

E D

IA

G R

A M

22P2

METERS & RELAYS2-2000-5 SS

(B 0 ) 1-2000-5

DISCONNECT

NEUTRAL

PERMANENT MAGNET GENERATORPMG

R

H E

R N

A N

D E

Z

Q9-79/750.24 MAIN SINGLE LINE DIAGRAM (UPDATED)

CLF

AM 64FVM

PMG

SI

SI

GOV

MOT

REG

VOLT

50 51 46

PPT

41G2

POWER POTENTIAL TRANSFORMERPPT

CLF CURRENT LIMITING FUSE

50 INSTANTANEOUS OVERCURRENT RELAY

51 AC TIME OVERCURRENT RELAY

46 REVERSE-PHASE-BALANCE CURRENT RELAY

41 FIELD CIRCUIT BREAKER

3. DETAILS REMOVED FOR CLARITY.

2. UNIT 2 SHOWN OTHER UNITS SIMILAR.

1. BOLD ITEMS INDICATE NEW EQUIPMENT.

IEEE / USACE SYMBOLS

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/9 /2

BORDER VERSION UPDATE [09-2012]

n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

E-101SHEET NAME:g2hdcbbm Bijan MasoumpanahBY USERNAME:DATE AND TIME PLOTTED: 6/9/2016 1:25:48 PM

P -1 .0

E -2

X X

X .d g n

E-201

S T

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C B

P E

A N

S I F

B A

R K

L E

Y D

A M P

R O J E

C T

P O

W E

R H

O U

S E

N A

S H

V

IL

L E T

E N

N E

S S

E E

A P

E S

O L

A

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

C U

M B

E R

L A

N D R

IV

E R

K E

N T

U C

K Y

U N

IT

S -4 E

X C

IT

A T

IO

N S

Y S

T

R E

P L

A C

E M

E N

T

8 7 6

& ACCESSORIES

GEN. HRG LOAD

& DISC.

GEN. HRG TRANS.

SURGE COMPT.

INSTR. TRANSF. &

GEN. MAIN VCBPOTHEAD CUBICLE

UNIT BD. NO.1

CONTR. JT.

G J

MAIN GATE ACB

EL. 366.0

9" CABLE TRAY

TRAY WITH BARRIERS

20" METAL CABLE

REFERENCE DRAWINGS:

NOTES:

Q9 - 79 / 704.3

2Y4

2Y3

2Y2

2Y12

DRAWING NUMBER TITLE

EXC

EL.347.0

EL.333.5

BOLD

EL.366.0

EL.331.0

EL.347.0

EL.331.0

EL. 331.0

LEGEND:

CLF CURRENT LIMITING FUSES

PPT POWER POTENTIAL TRANSFORMER

EXC

UNIT NO. 2

UNIT NO. 2

15 KV SWITCHGEAR ARRANGEMENT

C L

F

PPT

A C E

Q U

IP

M E

N T

IN

S

T A

L L

AS SPECIFIED

TRANSITION POINT,

TAP 13.8 KV BUS AT

AND SURGE COMPT.

INSTRUMENT TRANSF.

R

H E

R N

A N

D E

Z

SYSTEM EQUIPMENT

NEW EXCITATION

NEW AC BUS

EL. 335.5

AND SURGE COMPT.

INSTRUMENT TRANSF.

(FRONT)

UNIT BOARD NO.2

EXCPPT EXCPPT

CONTR. JT.

FAN ROOM 4

DN

G

6 7 8 9

J

UNIT NO. 1

10 11

13 14 15 16

No.1

LTG. TFMR.

No.2

LTG. TFMR.

No.1

SS TFMR.

No.1

SS TFMR.

GEN. LEADS BUS DUCT BELOW

POTHEAD CUBICLE

SS TFMR No 1 ACB

GEN. MAIN VCB

480 V. MAIN AVX BOARD

AND AC BUS

NEW CLF

AND AC BUS

NEW CLF

UNIT NO. 1

DUCT 2000A

GEN. LEADS BUS

CONTR. JT.

G

J

DN

EL. 333.5

UP

10 11 12 13 14 15 16

UNIT BD. NO 1

BUS HERE

TAP 13.8 KV

UNIT BD. NO 2

AC BUS

NONSEGREGATED

NEW

EQUIPMENT

NEW EXCITATION

EQUIPMENT

NEW EXCITATION

5'-1"

C

POTHEAD CUBICLE

GEN.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .