This solicitation notice is for a firm fixed-price construction contract to repair interior building 631 at the 133d Air Wing, Air National Guard Base in St. Paul, Minnesota. Work includes removing wallpaper and preparing walls for paint, replacing gypsum ceilings and bathroom fixtures, replacing sink countertops and floor and wall tiles, replacing light fixtures with LED, and replacing four hot water entryway heaters. The magnitude is between $500,000 and $1,000,000, and work must be completed within 90 days of the notice to proceed. The NAICS code is 236220. The small business size standard is $39.5 million, and this is a small business set-aside. The pre-proposal conference is August 9, 2022 and the solicitation closes August 31, 2022. The source selection will be best value tradeoff with past performance and price factors. The government intends to award without discussions. Interested offerors must register in SAM. The solicitation and questions will be available on beta.SAM.gov.

View the file

Other files

File Type Posted
Addendum 02 B631 Rpr Interior.docx DOCX document
09310.pdf PDF
06410.pdf PDF
1138-09-A11-01.pdf PDF
Qestion and Answers.zip ZIP file
QJKL222008 - SOW B631 Interior Finishes Repair 15AUG.pdf PDF
Addendum 01 B631 Rpr Interior.docx DOCX document
B 07 Preproposal Conference B631.pptx PPTX presentation
Interior Finish Sign-in Sheet.pdf PDF
QJKL222008 - SOW B631 Interior Finishes Repair.pdf PDF
EXHIBIT A B631 (Attachment).docx DOCX document
EXHIBIT C Reference_Questionnaire_Package B631 (Attachment).docx DOCX document
EXHIBIT B B631 (Attachment).docx DOCX document
EXHIBIT D Letter of Commitment B631 (Attachment).docx DOCX document
A 03 631 2nd Floor Plan.pdf PDF
A 03 631 Entryway Heaters Locations.pdf PDF
A 03 631 E2 LIGHTING.pdf PDF
B 08 W912LM-22-R-1005 Rpr Interior B631.pdf PDF
EXHIBIT B B631 (Attachment).docx DOCX document
A 03 1138-09-A9-3.pdf PDF
EXHIBIT C Reference_Questionnaire_Package B631 (Attachment).docx DOCX document
A 03 631 E1 Lighting.pdf PDF
EXHIBIT D Letter of Commitment B631 (Attachment).docx DOCX document
A 03 G1.1-G1.2 B682.pdf PDF
A 03 631 A3.1 Kub.pdf PDF
A 03 1138-09-A6-1.pdf PDF
EXHIBIT A B631 (Attachment).docx DOCX document
A 03 631 1st Floor Plan.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MNANG – Composite Maintenance Facility DOOR HARDWARE

1138.09 – CD 08710 - 1

SECTION 08710

DOOR HARDWARE

PART 1 - GENERAL

1.1 CONDITIONS

A. Conditions of the contract (General and Supplementary Conditions) and Division One General

Requirements, govern the work of this section.

B. This section includes all material, and related service necessary to furnish all finish hardware indicated on the drawings, or specified herein.

C. Furnish UL listed hardware for all labeled and 20 min. openings in conformance with the requirements for the class of opening scheduled. Underwriters' requirements shall have precedence over specification where conflicts exist.

D. All work shall be in accordance with all applicable state and local building codes. Code requirements shall have precedence over this specification where conflicts exist.

1.2 WORK INCLUDED

A. This section includes the following:

1. Furnish door hardware (for hollow metal, wood and aluminum doors) specified herein, listed in the hardware schedule, and/or required by the drawings.

2. Cylinders for Aluminum Doors

3. Thresholds and Weather-stripping (Aluminum frame seals to be provided by aluminum door supplier)

4. Electro-Mechanical Devices

5. Access Control components and or systems specified within this section.

B. Where items of hardware are not definitely or correctly specified and is required for the intended service, such omission, error or other discrepancy should be directed to the Architect prior to the bid date for clarification by addendum. Otherwise furnish such items in the type and quantity established by this specification for the appropriate service intended.

1.3 RELATED WORK IN OTHER SECTIONS

A. This section includes coordination with related work in the following sections:

1. Division 6 Section "Finish Carpentry".

2. Division 6 Section "Cabinet Hardware"

3. Division 8 Section "Hollow Metal Doors and Frames".

4. Division 8 Section "Wood Doors"

5. Division 8 Section "Aluminum Entrances and Storefronts"

6. Division 16 Sections "Electrical".

1.4 REFERENCES

A. Publications of agencies and organizations listed below form a part of this specification section to the extent referenced.

1. BMHA - Recommended Locations for Builders' Hardware.

2. NFPA 80 - Standards for Fire Doors and Windows.

3. NFPA 101 - Code for Safety to Life from Fire in Buildings and Structures.

4. UL - Building Material Directory.

5. DHI - Door and Hardware Institute

6. WHI - Warnock Hersey

7. IBC 2000 - International Building Code 2000 Edition (as amended by local building code)

1.5 SUBMITTALS

A. Within ten days after award of contract, submit detailed hardware schedule in quantities as required by Division 1 - General Conditions.

B. Schedule format shall be consistent with recommendations for a vertical format as set forth in the Door & Hardware Institute's (DHI) publication "Sequence and Format for the Hardware

1138.09 – CD 08710 - 2

Schedule". Hardware sets shall be consolidated to group multiple door openings which share similar hardware requirements. Schedule shall include the following information:

1. Door number, location, size, handing, and rating.

2. Door and frame material, handing.

3. Degree of swing.

4. Manufacturer

5. Product name and catalog number

6. Function, type and style

7. Size and finish of each item

8. Mounting heights

9. Explanation of abbreviations, symbols, etc.

10.Numerical door index, indicating the hardware set/ group number for each door.

C. The schedule will be prepared under the direct supervision of a certified Architectural Hardware Consultant (AHC) employed by the hardware distributor. The hardware schedule shall be signed and embossed with the DHI certification seal of the supervising AHC. The supervising AHC shall attend any meetings related to the project when requested by the architect.

D. Check the specified hardware for suitability and adaptability to the details and surrounding conditions.

E. Review drawings from related trades as required to verify compatibility with specified hardware.

Indicate unsuitable or in compatible items, and proposed substitutions in the hardware schedule.

F. Provide documentation for all hardware to be furnished on labeled fire doors indicating compliance with positive pressure fire testing UL 10C.

G. Furnish manufacturers' catalog data for each item of hardware in quantities as required by Division 1 - General Conditions.

H. Submit a sample of each type of hardware requested by the architect. Samples shall be of the same finish, style, and function as specified herein. Tag each sample with its permanent location so that it may be used in the final work.

I. Furnish with first submittal, a list of required lead times for all hardware items.

J. After final approved schedule is returned, transmit corrected copies for distribution and field use in quantities as required by Division 1 - General Conditions.

K. Furnish approved hardware schedules, template lists, and pertinent templates as requested by related trades.

L. Furnish necessary diagrams, schematics, voltage and amperage requirements for all electro-mechanical devices or systems as required by related trades.

M. After receipt of approved hardware schedule, Hardware supplier shall initiate a meeting including the owner's representative to determine keying requirements. Upon completion of the initial key meeting, hardware supplier shall prepare a proposed key schedule with symbols and abbreviations as set forth in the door and hardware institute's publication "Keying Procedures, Systems, and Nomenclature". Submit copies of owner approved key schedule for review and field use in quantities as required by Division 1 - General Conditions.

1.6 QUALITY ASSURANCE

A. Manufacturers and model numbers listed are to establish a standard of function and quality.

Similar items by approved manufacturers that are equal in design, function, and quality, may be considered for prior approval of the architect, provided the required data and physical samples are submitted for approval as set forth in Division One General Requirements.

B. Obtain each type of hardware (hinges, latch & locksets, exit devices, closers, etc.) from a single manufacturer, although several may be indicated as offering products complying with requirements.

C. Installation of hardware shall be installed or directly supervised and inspected by a skilled installer certified by the manufacturer of locksets, door closers, and exit devices used on the

1138.09 – CD 08710 - 3

project, or with not less than 3 years experience in successful completion of projects similar in size and scope.

D. Provide hardware for all labeled fire doors, which complies with positive pressure fire testing

UL 10C.

E. Comply with all applicable provisions of the standards referenced within section 1.4 of this specification.

1.7 DELIVERY, STORAGE AND HANDLING

A. Hardware supplier shall deliver hardware to the job site unless otherwise specified.

B. All hardware shall be delivered in manufacturers' original cartons and shall be clearly marked with set and door number.

C. Coordinate with contractor prior to hardware delivery and recommend secure storage and protection against loss and damage at job site.

D. Contractor shall receive all hardware and provide secure and proper protection of all hardware items to avoid delays caused by lost or damaged hardware. Contractor shall report shortages to the Architect and hardware supplier immediately after receipt of material at the job site.

E. Coordinate with related trades under the direction of the contractor for delivery of hardware items necessary for factory installation.

1.8 PRE-INSTALLATION MEETING

A. Schedule a hardware pre-installation meeting on site to review and discuss the installation of continuous hinges, locksets, door closers, exit devices, overhead stops, and electromechanical door hardware.

B. Meeting attendees shall be notified 7 days in advance and shall include: Architect, Contractor, Door Hardware Installers (including low voltage hardware), Manufacturers representatives for above hardware items, and any other effected subcontractors or suppliers.

C. All attendees shall be prepared to distribute installation manuals, hardware schedules, templates, and physical hardware samples.

1.9 WARRANTY

A. All hardware items shall be warranted against defects in material and workmanship as set forth in Division One General Requirements.

B. Repair, replace, or otherwise correct deficient materials and workmanship without additional cost to owner.

PART 2 - PRODUCTS

2.1 FASTENERS

A. All exposed fasteners shall be Phillips head or as otherwise specified, and shall match the finish of the adjacent hardware. All fasteners ex-posed to the weather shall be non-ferrous or stainless steel. Furnish correct fasteners to accommodate surrounding conditions.

B. Coordinate required reinforcements for doors and frames. Seek approval of the architect prior to furnishing through-bolts. Furnish through-bolts as required for materials not readily reinforced.

2.2 BUTT HINGES

A. Acceptable manufacturers and respective catalog numbers:

Ives Stanley Hager McKinney

1. Standard Weight, Plain Bearing 5PB1 F179 1279 T2714

2. Standard Weight, Ball Bearing 5BB1 BB179 BB1279 TB2714

3. Standard Weight, Ball Bearing, Non-Ferrous 5BB1 FBB191 BB1191 TB2314

4. Heavy Weight, Ball Bearing 5BB1HW FBB168 BB1168 T4B3786

1138.09 – CD 08710 - 4

5. Heavy Weight, Ball Bearing, Non-Ferrous 5BB1HW FBB199 BB1199 T4B3386 B. Unless otherwise specified, furnish the following hinge quantities for each door leaf.

1. 3 hinges for doors up to 90 inches.

2. 1 additional hinge for every 30 inch on doors over 90 inches.

3. 4 hinges for Dutch door applications.

C. Unless otherwise specified, furnish hinge weight and type as follows:

1. Standard weight: plain bearing hinge 5PB1 for interior openings through 36 inches wide without a door closer.

2. Standard weight: ball bearing hinge 5BB1 for interior opening over 36 through 40 inches wide without a door closer, and for interior openings through 40 inches wide with a door closer.

3. Heavyweight: 4 ball bearing hinge 5BB1HW for interior openings over 40 inches wide, and for all vestibule doors.

4. Heavyweight: 4 ball bearing hinge 5BB1HWss for exterior openings unless otherwise listed in groups.

D. Unless otherwise specified, furnish hinges for exterior doors, fabricated from brass, bronze, or stainless steel. Unless otherwise specified, hinges for interior doors may be fabricated from steel.

E. Unless otherwise specified, furnish hinges in the following sizes:

1. 5" x 5" 2-1/4" thick doors

2. 4-1/2" x 4-1/2" 1-3/4" thick doors

3. 3-1/2" x 3-1/2" 1-3/8" thick doors

F. Furnish hinges with sufficient width to accommodate trim and allow for 180-degree swing.

G. Unless otherwise specified, furnish hinges with flat button tips with non-rising pins at interior doors, non-removable loose pins (NRP) at exterior and out-swinging interior doors.

H. Unless otherwise specified, furnish all hinges to template standards.

2.3 FLUSH BOLTS AND DUST PROOF STRIKES

A. Acceptable manufacturers and respective catalog numbers:

Ives Door Controls Hager

1. Dust Proof Strike DP2 80 280X

2. Auto Flush Bolt (Metal Door) FB31P 842 292D

3. Auto Flush Bolt (Wood Door) FB41P 942 291D

4. Manual Flush Bolt FB458 780 282D

B. Unless otherwise specified, provide 12" rods for manual flush bolts for door 7'6" or less, 24" top rods for doors over 7'6" to 8'6".

C. Unless otherwise specified, provide doors over 8'6" with automatic top bolts.

D. Provide automatic flush bolts where required to maintain egress requirements on pairs of doors.

E. Provide all flush bolts with non-locking dust proof strikes.

2.4 EXIT DEVICES

A. Acceptable manufacturers and respective catalog numbers:

Von Duprin Monarch Sargent Yale Corbin

1. Wide Stile, Push Pad 98 / 99 Series 18 Series GL-43-80 Series 7100

Series

ED5000

Series

2. Lever Trim 996 Series 180 Series 740 ET 600 Series 900 Series

3. Pull Trim 990 Series Vanguard 800 MAL 500 Series 1300 Series

B. Obtain exit devices from a single manufacturer, although several may be indicated as offering products complying with requirements.

1138.09 – CD 08710 - 5

C. All exit devices shall be U.L. listed for accident hazard. Exit device for use on fire doors shall also be U.L. listed for fire exit hardware.

D. Provide optional strikes, special length rods, and adapter plates to accommodate door and frame conditions. Provide narrow style series devices in lieu of wide stile series devices where optional strikes will not accommodate door and frame conditions.

E. Coordinate with related trades to insure adequate clearance and reinforcement is provided in doors and frames. Provide thru bolts as required.

F. Refer to hardware groups for exit device applications utilizing the option of: "less bottom rod and floor strike" (LBR)

G. All exit devices shall be provided with optional trim designs to match other lever and pull designs used on the project.

H. Provide interchangeable core cylinders when used in conjunction with exit devices. Cylinder keyway shall match locksets furnished on this project.

I. Provide cylinder keyed dogging (interchangeable core) for all non-fire rated exit devices.

J. Provide glass bead kits as required to accommodate door conditions. Screws shall not be visible through full glass doors.

K. Where specified, provide compatible keyed mullions with cylinder for pairs of doors.

L. Provide reinforced crossbars for all traditional style exit devices applied to doors over 36" wide.

2.5 LOCKS AND LATCHES

A. Acceptable manufacturers and respective catalog numbers:

Schlage Falcon Best Sargent Yale Corbin

1. Grade 1

Cylindrical ND Series

ATH

T Series A

9K Series 16D

10 Line

LB

5400LN Series

MO

CL3300

AZD

B. Unless otherwise specified, all locks and latches to have:

1. 2-3/4" Backset

2. 1/2" minimum throw latchbolt

3. 1" throw deadbolt

4. 6 pin cylinders

5. ANSI A115.2 strikes

C. Provide guarded latch bolts for all locksets, and latch bolts with sufficient throw to maintain fire rating of both single and paired door assemblies.

D. Length of strike lip shall be sufficient to clear surrounding trim.

E. Provide wrought boxes for strikes at inactive doors, wood frames, and metal frames without integral mortar covers.

2.6 PULLS, PUSH BARS, PUSH/PULL PLATES

A. Acceptable manufacturers and respective catalog numbers:

Burns Hager Ives

1. Straight Pull (1" dia., 10" ctc) 26C 4J 8103EZ-0

2. Straight Pull (3/4” dia., 8” ctc) 25B 3G 8102-8

3. Offset Door Pull (1" dia., 10" ctc) 39C 12J 8190-0

4. Pull / Push-Bar (1" dia., 10" ctc Pull) 422 x 26C 153 9103EZ-0

5. Offset Pull / Push-Bar (1" dia., 10" ctc Pull) 422 x 39C 157 9190-0

6. Push Plate (.050 4"X 16") 54 30S 4 x 16 8200 4 x 16

7. Push Plate (.050 6"X 16") 56 30S 6 x 16 8200 6" X 16"

8. Pull Plate (1" dia., 10" ctc - .050" X 6" X 16") 5626C 34J 6 x 16 8303EZ-0 6" X 16"

B. Adjust dimensions of protection plates to accommodate stile and rail dimensions, lite and louver cutouts, and adjacent hardware. Where required by adjacent hardware, protection plates shall be factory drilled for cylinders or other mortised hardware. All push plates shall be beveled 4 sides and counter sunk.

1138.09 – CD 08710 - 6

C. Where specified, provide surface mounted door edges. Edges shall butt to protective plates.

Provide edges with cutouts as required adjacent hardware.

D. Where possible, provide back-to-back, and concealed mounting for pulls and push bars. Push bar length shall be 3" less door width, or center of stile to center of stile for stile & rail or full glass doors.

2.7 COORDINATORS

A. Acceptable manufacturers and respective catalog numbers:

Ives Door Controls Hager

1. Bar Coordinator COR x FL 600 x Filler 297D x 297F

2. Mounting Bracket MB Series AB, C Series 297 Series

B. Provide coordinators at all pairs of doors having automatic flush bolts and closers on the inactive leaf, and for pairs of doors having vertical rod/mortise exit device combinations with overlapping astragals.

C. Provide appropriate filler bars, closer mounting brackets, carry bars, and special top latch preparations as required by adjacent hardware.

2.8 CLOSERS

A. Acceptable manufacturers and respective catalog numbers:

LCN Dor-O-Matic Sargent Yale Norton

1. 4011 /4111 EDA SC70 / SC70 HD 350 / 351 P10 4400 / PR4400 7500 / PR7500

B. Obtain door closers from a single manufacturer, although several may be indicated as offering products complying with requirements.

C. Closers shall utilize a stable fluid withstanding temperature range of +120deg F to -30deg F without seasonal adjustment of closer speed to properly close the door. Closers for fire-rated doors shall be provided with temperature stabilizing fluid that complies with standards UL10C.

D. Unless otherwise specified, all door closers shall have full covers and separate adjusting valves for sweeps, latch, and backcheck.

E. Provide closers for all labeled doors. Provide closers with adjustable spring power. Size closers to insure exterior and fire rated doors will consistently close and latch doors under existing conditions. Size all other door closers to allow for reduced opening force not to exceed 5 lbs.

F. Install closers on the room side of corridor doors, stair side of stairways and interior side of exterior doors.

G. Closers shall be furnished complete with all mounting brackets and cover plates as required by door and frame conditions, and by adjacent hardware.

2.9 LOW ENERGY ELECTRO-HYDRAULIC AUTOMATIC OPERATORS

A. Acceptable manufacturers and respective catalog numbers:

LCN

1. Electro-Hydraulic Operator 4640

B. Where low kinetic energy, as defined by ANSI/BHMA Standard A156.19, power operators are indicated for doors required to be accessible to the disabled, provide electrically powered operators complying with the ADA for opening force and time to close standards.

C. The closing action shall be controlled by modern type cast iron door closer cylinder filled with a flat viscosity fluid, stable from +120F to -30F that would require no seasonal adjustments. The closer shall have field adjustable spring power; have two independent closing speed adjustment valves, and hydraulic back-check.

D. Full closing force shall be provided when the power or assist cycle ends.

E. All power operator systems shall include the following features and functions:

1138.09 – CD 08710 - 7

1. Provisions for separate conduits to carry high and low voltage wiring in compliance with the National Electrical Code, section 725-31.

2. The operator will be designed to prevent damage to the mechanism if the system is actuated while the door is latched or if the door is forced closed during the opening cycle.

3. All covers, mounting plates and arm systems shall be powder coated and successfully pass a minimum of 100 hours testing as outlined in ANSI/BHMA Standard A156.18.

4. UL listed for use on labeled doors.

5. All operators shall be non-handed with spring power over a range of at least four sizes;

either 1 through 4 or 2 through 5.

6. Provisions in the control box or module shall provide control {inputs and outputs) for;

electric strike delay, auxiliary contacts, sequential operation, fire alarms systems, actuators, swing side sensors, and stop side sensors.

7. Wall mounted actuators shall consist of a 4-1/2 inch diameter stainless steel touch plate with a blue filled handicapped symbol. Switches shall be weather resistant and mount on a single gang electrical box furnished by Division 16.

F. All electrically powered operators shall include the following features or functions:

1. When an obstruction or resistance to the opening swing is encountered, the operator will pause at that point, then attempt to continue opening the door. If the obstruction or resistance remains, the operator will again pause the door.

2. Easily accessible main power and maintain hold open switches will be provided on the operator.

3. An electronically controlled clutch to provide adjustable opening force.

4. A microprocessor to control all motor and clutch functions.

5. An on-board power supply capable of delivering both 12V and 24V outputs up to a maximum of 1.0 ampere combined load.

6. All input and output power wiring shall be protected by slow blow fuses. These fuses shall be easily replaceable without special tools or component replacement.

7. If electrical failure occurs, the unit shall operate as a standard door closer.

G. Power Operators shall be warranted by the manufacture to be free from defects in material and workmanship for a period of two years.

2.10 KICK PLATES AND MOP PLATES

A. Furnish protective plates as specified in hardware groups.

B. Where specified, provide 10" kick plates, 36" armor plates, and 4" mop plates. Unless otherwise specified, metal protective plates shall be .050" thick; plastic plates shall be 1/8" thick.

C. Protective plates shall be 2" less door width, or 1" less door width at pairs. All protective plates shall be beveled 4 sides and counter sunk. Protection plates over 16" shall not be provided for labeled doors unless specifically approved by door manufacturers listing.

D. Where required by adjacent hardware, protection plates shall be factory drilled for cylinders or other mortised hardware.

2.11 OVERHEAD STOPS

A. Acceptable manufacturers and respective catalog numbers:

Glynn-Johnson Rixson Sargent

1. Heavy Duty Surface Mount GJ90 Series 9 Series 590

2. Heavy Duty Concealed Mount GJ100 Series 1 Series 690

3. Medium Duty Surface Mount GJ450 Series 10 Series 1540

4. Medium Duty Concealed Mount GJ410 2 Series 1530

B. Overhead stops (including slide block and end caps) shall be fabricated from metal.

C. Unless otherwise specified, furnish GJ900 series overhead stop for doors equipped with regular arm surface type closers that swing more than 140 degrees before striking a wall, for doors that open against equipment, casework, sidelights, or other objects that would make wall bumpers inappropriate, and as specified in hardware groups.

1138.09 – CD 08710 - 8

D. Furnish sex bolt attachments for wood and mineral core doors unless doors are supplied with proper reinforcing blocks.

E. Do not provide holder function for labeled doors.

2.12 WALL STOPS AND HOLDERS

A. Acceptable manufacturers and respective catalog numbers:

Ives Hager Burns

1. Wrought Convex Wall Bumper WS406CVX 232W 570

2. Wrought Concave Wall Bumper WS406CCV 236W 575

3. Extended Wall Stop WS11/WS11X 255W 530

4. Extended Wall Stop WS33/WS33X **** ****

5. Automatic Wall Holder WS40 254W 533

B. Furnish a stop or holder for all doors. Furnish floor stops only where specifically specified.

C. Where wall stops are not applicable, furnish overhead stops.

D. Do not provide holder function for labeled doors.

2.13 MAGNETIC HOLD OPENS

A. Acceptable manufacturers and respective catalog numbers:

LCN ABH Edwards

1. Wall Holder SEM 7800 2000 1500

B. Magnetic holder's housing and armature shall be constructed of a die cast zinc material.

C. Provide types as listed in groups.

D. Where wall conditions do not permit the armature to reach the magnet, provide extensions.

E. Provide proper voltage and power consumption as required by Division 16.

F. Coordinate electrical requirements and mounting locations with other trades.

2.14 WEATHERSTRIP, GASKETING

A. Acceptable manufacturers and respective catalog numbers:

Pemko NGP Reese

1. Weatherstrip 2891APK 700NA 755A

2. Adhesive Gasket S88D 2525 797B

3. Meeting Edge Seals 18041 9605 959C

4. Adhesive Edge Seal S77 5060 ****

5. Automatic Door Bottom 4131 222 320

6. Sweeps 18061CP B606A 964A

7. Sweep w/ drip 345 **** ****

8. Drip Cap 346A 16A R201A

B. Where specified in the hardware groups, furnish the above products unless otherwise detailed in groups.

C. Provide weatherstripping all exterior doors and where specified.

D. Provide intumescent and other required edge sealing systems as required by individual fire door listings to comply with positive pressure standards UL 10C.

E. Provide S88D smoke gaskets at all fire rated doors and smoke and draft control assemblies.

2.15 THRESHOLDS

A. Acceptable manufacturers and respective catalog numbers:

Pemko NGP Reese

1. Saddle Thresholds 171 425 S205

2. Half Saddle Thresholds 227 324 S239

B. Hardware supplier shall verify all finish floor conditions and coordinate proper threshold as required to insure a smooth transition between threshold and interior floor finish.

1138.09 – CD 08710 - 9

C. Threshold Types:

1. Unless otherwise specified, provide saddle threshold similar to Reese S205 for all exterior openings with a interior floor finish less than or equal to 1/4" in height.

2. Unless otherwise specified, provide half saddle threshold similar to Reese S239 for all exterior openings with a interior floor finish greater than 1/4" in height. Threshold height shall match thickness of interior floor finish.

2.16 ELECTRIC STRIKES

A. Acceptable manufacturers and respective catalog numbers:

Von Duprin Folger Adams

1. Type 1 6000 Series 300 Series

B. Provide electric strikes designed for use with the type of locks shown at each opening where specified.

C. Electric strikes shall be UL listed as Burglary-Resistant Electric Door Strikes and where required shall be UL listed as Electric Strike for Fire Doors.

D. Provide transformers and rectifiers for each strike as required. Verify voltage with electrical contractor.

2.17 SLIDING DOOR HARDWARE

A. Acceptable Manufacturers and respective catalog numbers:

Lawrence

1. Solid Core Bi-Pass Hardware Set ED520 Series

2. Solid Core Pocket Door Hardware Set PF614

B. Provide complete hardware sets for each opening specified with sliding door hardware.

Include track, ball-bearing hangers, door stops, fasteners, guides, and all hardware required for a complete installation.

C. Provide header and jamb posts for pocket door sets as required by wall thickness.

2.18 FINISHES AND BASE MATERIALS

A. Unless otherwise indicated in the hardware groups or herein, hardware finishes shall be applied over base metals as specified in the following finish schedule:

HARDWARE ITEM BHMA FINISH AND BASE MATERIAL

1. Butt Hinges: Exterior, or Non-Ferrous 630 (US32D)

2. Butt Hinges: Interior 652 (US26D)

3. Continuous Hinges 630 (US32D)

4. Flush Bolts 626 (US26D)

5. Exit Devices 626 (US26D)

6. Locks and Latches 626 (US26D)

7. Pulls and Push Plates/Bars 630 (US32D)

8. Coordinators 600 (Prime painted or mill alum.)

9. Closers 689 (Powder Coat Aluminum)

10. Protective Plates 630 (US32D)

11. Overhead Stops 630 (US32D)

12. Wall Stops and Holders 630 (US32D)

13. Thresholds 628 (Mill Aluminum)

14. Weather-strip, Sweeps Drip Caps Aluminum Anodized

15. Magnetic Holders Sprayed Aluminum

16. Magnetic Locks 628 (US28)

17. Miscellaneous 626 (US26D)

2.19 KEYING

A. Acceptable manufacturers and respective catalog numbers:

1. Best B. All locks under this section shall be keyed as directed by the owner to an existing Best Master

Key System.

1138.09 – CD 08710 - 10

C. Keying shall be by lock manufacturer where permanent records shall be kept.

D. Furnish a total of 2 keys per cylinder. Actual cut keys to be determined by owner.

2.20 KEY CABINETS

A. Acceptable manufacturers and respective catalog numbers:

Lund Key Control Telkee

1. 1200-1205 AA M228-2480 RWC-AWC

B. Furnish 1 each model 1200 or 1205 AA key cabinet with a capacity 1.5 times the number of key sets.

C. Provide one key cabinet with at least one hook for each key set, plus additional hooks for 50% expansion.

D. Furnish key cabinet complete with cam lock, permanent key tags, and change key cards.

E. Hardware supplier shall prepare all key change index records, tag all keys and place permanent file keys in cabinet.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Prior to installation of hardware, installer shall examine door frame installation to insure frames have been set square and plumb. Installer shall examine doors, door frames, and adjacent wall, floor, and ceiling for conditions, which would adversely effect proper operation and function of door assemblies. Do not proceed with hardware installation until such deficiencies have been corrected.

3.2 INSTALLATION

A. Before hardware installation, general contractor/construction manager shall coordinate a hardware installation seminar with a 1 week notice to all parties involved. The seminar is to be conducted on the installation of hardware, specifically of locksets, closers, exit devices, continuous hinges and overhead stops. Manufacturer's representative of the above products to present seminar. Seminar to be held at the job site and attended by installers of hardware (including low voltage hardware) for aluminum, hollow metal and wood doors. Training to include use of installation manuals, hardware schedule, templates and physical products samples.

B. Install all hardware in accordance with the approved hardware schedule and manufacturers instructions for installation and adjustment.

C. Set units level, plumb and true to the line and location. Adjust and reinforce the attachment substrate as necessary for proper installation and operation.

D. Drill and countersink units which are not factory-prepared for anchorage fasteners. Space fasteners and anchors in accord with industry standards.

E. Drill appropriate size pilot holes for all hardware attached to wood doors and frames.

F. Shim doors as required to maintain proper operating clearance between door and frame.

G. Unless otherwise specified, locate all hardware in accordance with the recommended locations for builders hardware for standard doors and frames as published by the Door and Hardware Institute.

H. Use only fasteners supplied by or approved by the manufacturer for each respective item of hardware.

I. Mortise and cut to close tolerance and conceal evidence of cutting in the finished work.

J. Conceal push and pull bar fasteners where possible. Do not install through bolts through push plates.

1138.09 – CD 08710 - 11

K. Install hardware on UL labeled openings in accordance with manufacturer's requirements to maintain the label.

L. Install hardware in accordance with supplemental "S" label instructions on all fire rated openings.

M. Install wall stops to contact lever handles or pulls. Do not mount wall stops on casework, or equipment.

N. Where necessary, adjust doors and hardware as required to eliminate binding between strike and latchbolt. Doors should not rattle.

O. Install door closers on corridor side of lobby doors, room side of corridor doors, and stair side of stairways.

P. Adjust spring power of door closers to insure exterior and fire rated doors will consistently close and latch doors under existing conditions. Adjust all other door closers to insure opening force does not to exceed 5 lbs.

Q. Adjust "sweep", "latch", & "back check" valves on all door closers to properly control door through out the opening and closing cycle. Adjust total closing speed as required to comply with all applicable state and local building codes.

R. Unless otherwise specified or detailed, install thresholds with the bevel in vertical alignment with the outside door face. Notch and closely fit thresholds to frame profile. Set thresholds in full bed of sealant.

S. Compress sweep during installation as recommended by sweep manufacturer to facilitate a water resistant seal.

T. Deliver to the owner 1 complete set of installation and adjustment instructions, and tools as furnished with the hardware.

3.3 QUALITY ASSURANCE

A. After installation has been completed, the hardware supplier and manufacturers representative for locksets, door closers, exit devices, and overhead stops shall check the project and verify compliance with installation instructions, adjustment of all hardware items, and proper application according to the approved hardware schedule. Hardware supplier shall submit a list of all hardware that has not been installed correctly.

B. After installation has been completed, the hardware supplier and manufacturers representative shall meet with the owner to explain the functions, uses, adjustment, and maintenance of each item of hardware.

C. Apply self-adhesive gasketing on frame stop at head & latch side and on rabbet of frame at hinge side.

3.4 ADJUSTMENT AND CLEANING

A. At final completion, and when H.V.A.C. equipment is in operation, installer shall make final adjustments to and verify proper operation of all door closers and other items of hardware. .

Lubricate moving parts with type lubrication recommended by the manufacturer.

B. All hardware shall be left clean and in good operation. Hardware found to be disfigured, defective, or inoperative shall be repaired or replaced.

3.5 HARDWARE SCHEDULE

A. The following schedule of hardware groups are intended to describe opening function. The hardware supplier is cautioned to refer to the preamble of this specification for a complete description of all materials and services to be furnished under this section.

HW SET: 01

1 SET BI-PASS HARDWARE ED500 LAW

1138.09 – CD 08710 - 12

SET

2 EA SLIDING DOOR PULL S2002B ACC

HW SET: 02

EA HINGES AS SPECIFIED IVE

1 EA PASSAGE SET T101 FAL

1 EA WALL STOP WS406CVX IVE

FUNCTION: T101 (F75-1) Passage/Closet Latchset Latch bolt by levers at all times.

HW SET: 03

EA HINGES AS SPECIFIED IVE

1 EA PASSAGE SET T101 FAL

1 EA HD OVERHEAD STOP 900S GLY

FUNCTION: T101 (F75-1) Passage/Closet Latchset Latch bolt by levers at all times.

HW SET: 04

EA HINGES AS SPECIFIED IVE

1 EA CLASSROOM LOCK T561 FAL

1 EA CYLINDER AS REQUIRED BES

1 EA WALL STOP WS406CVX IVE

FUNCTION: T561 (F84-1) Classroom Lock Deadlocking latch bolt by levers. Outside lever is locked by key in outside lever. Inside lever is always free.

HW SET: 05

EA HINGES AS SPECIFIED IVE

1 EA CLASSROOM LOCK T561 FAL

1 EA CYLINDER AS REQUIRED BES

1 EA HD OVERHEAD STOP 900S GLY

FUNCTION: T561 (F84-1) Classroom Lock Deadlocking latch bolt by levers. Outside lever is locked by key in outside lever. Inside lever is always free.

HW SET: 06

EA HINGES AS SPECIFIED IVE

1 EA CLASSROOM LOCK T561 FAL

1 EA CYLINDER AS REQUIRED BES

1 EA WALL STOP WS406CVX IVE

1 SET SEALS 49 REE

1 EA DOOR BOTTOMS 372 REE

1 EA THRESHOLD AS REQUIRED

FUNCTION: T561 (F84-1) Classroom Lock Deadlocking latch bolt by levers. Outside lever is locked by key in outside lever. Inside lever is always free.

1138.09 – CD 08710 - 13

HW SET: 07

EA HINGES AS SPECIFIED IVE

1 EA STOREROOM LOCK T581 FAL

1 EA CYLINDER AS REQUIRED BES

1 EA WALL STOP WS406CVX IVE

FUNCTION: T581 (F86-1) Storeroom Lock Deadlocking latch bolt by lever inside or key outside. Outside lever is inoperable. Inside lever always free.

HW SET: 08

EA HINGES AS SPECIFIED IVE

1 EA POWER TRANSFER EPT-10 VON

2 EA MANUAL FLUSH BOLT FB458 IVE

1 EA DUST PROOF STRIKE DP2 IVE

1 EA STOREROOM LOCK T581 FAL

2 EA SURFACE CLOSER SC71 HD/PA DOR

2 EA HD OVERHEAD STOP 900S GLY

2 EA KICK PLATE 8400 10" X 1" LDW IVE

1 SET WEATHERSTRIP 755 REE

1 SET ASTRAGAL SEAL 959 REE

2 EA SWEEP 964 REE

1 EA RAIN DRIP R201 REE

1 EA THRESHOLD AS REQUIRED

NOTE: FUTURE CARD READER.

FUNCTION: T581 (F86-1) Storeroom Lock Deadlocking latch bolt by lever inside or key outside. Outside lever is inoperable. Inside lever always free.

HW SET: 09

EA HINGES AS SPECIFIED IVE

2 EA MANUAL FLUSH BOLT FB458 IVE

1 EA DUST PROOF STRIKE DP2 IVE

1 EA STOREROOM LOCK T581 FAL

1 EA CYLINDER AS REQUIRED BES

2 EA HD OVERHEAD STOP 900S GLY

FUNCTION: T581 (F86-1) Storeroom Lock Deadlocking latch bolt by lever inside or key outside. Outside lever is inoperable. Inside lever always free.

HW SET: 10

EA HINGES AS SPECIFIED IVE

2 EA MANUAL FLUSH BOLT FB458 IVE

1 EA DUST PROOF STRIKE DP2 IVE

1 EA STOREROOM LOCK T581 FAL

1 EA CYLINDER AS REQUIRED BES

2 EA WALL STOP WS406CVX IVE

FUNCTION: T581 (F86-1) Storeroom Lock Deadlocking latch bolt by lever inside or key outside. Outside lever is inoperable. Inside lever always free.

1138.09 – CD 08710 - 14

HW SET: 11

EA HINGES AS SPECIFIED IVE

2 EA SGL DUMMY TRIM T12 FAL

2 EA ROLLER LATCH RL32 (TOP MOUNT) IVE

2 EA HD OVERHEAD STOP 900S GLY

PROVIDE IVES #WS406 WALL STOP IN LIEU OF GLY #450 OVERHEAD STOP WHERE LEVER SHAFT

WILL CONTACT WALL.

FUNCTION: T12 Single Dummy Trim Single dummy trim for one side of door. Used for door pull or as matching inactive trim.

HW SET: 12

EA HINGES AS SPECIFIED IVE

1 EA CLASSROOM LOCK T561 FAL

1 EA CYLINDER AS REQUIRED BES

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA ARMOR PLATE 8400 36" X 2" LDW IVE

1 EA WALL STOP WS406CVX IVE

1 SET SMOKE GASKET 797 (AT RATED OR SMOKE & DRAFT CONTROL

DRS. ONLY)

REE

FUNCTION: T561 (F84-1) Classroom Lock Deadlocking latch bolt by levers. Outside lever is locked by key in outside lever. Inside lever is always free.

HW SET: 13

EA HINGES AS SPECIFIED IVE

1 EA CLASSROOM LOCK T561 FAL

1 EA CYLINDER AS REQUIRED BES

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA KICK PLATE 8400 10" X 2" LDW IVE

1 EA WALL STOP &

HOLDER

WS40 IVE

1 SET SEALS 49 REE

1 EA SWEEP 964 REE

1 EA THRESHOLD AS REQUIRED

FUNCTION: T561 (F84-1) Classroom Lock Deadlocking latch bolt by levers. Outside lever is locked by key in outside lever. Inside lever is always free.

HW SET: 14

EA HINGES AS SPECIFIED IVE

1 EA CLASSROOM LOCK T561 FAL

1 EA CYLINDER AS REQUIRED BES

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA OVERHEAD HOLDER 900H GLY

1 EA ARMOR PLATE 8400 36" X 2" LDW IVE

1 SET WEATHERSTRIP 755 REE

1 EA SWEEP 964 REE

1 EA RAIN DRIP R201 REE

1 EA THRESHOLD AS REQUIRED

FUNCTION: T561 (F84-1) Classroom Lock

1138.09 – CD 08710 - 15

Deadlocking latch bolt by levers. Outside lever is locked by key in outside lever. Inside lever is always free.

HW SET: 15

EA HINGES AS SPECIFIED IVE

1 EA CLASSROOM LOCK T561 FAL

1 EA CYLINDER AS REQUIRED BES

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA OVERHEAD HOLDER 900H GLY

1 EA KICK PLATE 8400 10" X 2" LDW IVE

1 SET WEATHERSTRIP 755 REE

1 EA SWEEP 964 REE

1 EA RAIN DRIP R201 REE

1 EA THRESHOLD AS REQUIRED

FUNCTION: T561 (F84-1) Classroom Lock Deadlocking latch bolt by levers. Outside lever is locked by key in outside lever. Inside lever is always free.

HW SET: 16

EA HINGES AS SPECIFIED IVE

1 EA CLASSROOM LOCK T561 FAL

1 EA CYLINDER AS REQUIRED BES

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA OVERHEAD HOLDER 900H GLY

1 EA KICK PLATE 8400 10" X 2" LDW IVE

FUNCTION: T561 (F84-1) Classroom Lock Deadlocking latch bolt by levers. Outside lever is locked by key in outside lever. Inside lever is always free.

HW SET: 17

EA HINGES AS SPECIFIED IVE

1 EA CLASSROOM LOCK T561 FAL

1 EA CYLINDER AS REQUIRED BES

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA OVERHEAD HOLDER 900H GLY

1 EA KICK PLATE 8400 10" X 2" LDW IVE

1 SET SEALS 49 REE

1 EA SWEEP 964 REE

1 EA THRESHOLD AS REQUIRED

FUNCTION: T561 (F84-1) Classroom Lock Deadlocking latch bolt by levers. Outside lever is locked by key in outside lever. Inside lever is always free.

HW SET: 18

EA HINGES AS SPECIFIED IVE

1 EA STOREROOM LOCK T581 FAL

2 EA CYLINDER AS REQUIRED BES

1 EA ELECTRIC STRIKE 6211 (FAIL SECURE) VON

1 EA AUTO-OPERATOR 4642 LCN

1 EA OVERHEAD HOLDER 900H GLY

1 EA KICK PLATE 8400 10" X 2" LDW IVE

1 SET WEATHERSTRIP 755 REE

1138.09 – CD 08710 - 16

1 EA SWEEP 964 REE

1 EA RAIN DRIP R201 REE

1 EA THRESHOLD AS REQUIRED

2 EA ACTUATOR 7910-956 LCN

1 EA WIRING DIAGRAM BY HARDWARE SUPPLIER

1 EA KEYSWITCH 653-1414-L2 LOC

FUNCTION: T581 (F86-1) Storeroom Lock Deadlocking latch bolt by lever inside or key outside. Outside lever is inoperable. Inside lever always free.

Exterior key switch will release electric strike to unlock door for extended periods. This door has a power operator. Interior actuator always active to unlock and open the door. Exterior actuator is active only when electric strike has been released by exterior key switch.

HW SET: 19

EA HINGES AS SPECIFIED IVE

1 EA STOREROOM LOCK T581 FAL

1 EA CYLINDER AS REQUIRED BES

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA KICK PLATE 8400 10" X 2" LDW IVE

1 EA WALL STOP WS406CVX IVE

1 SET SMOKE GASKET 797 (AT RATED OR SMOKE & DRAFT CONTROL

DRS. ONLY)

REE

FUNCTION: T581 (F86-1) Storeroom Lock Deadlocking latch bolt by lever inside or key outside. Outside lever is inoperable. Inside lever always free.

HW SET: 20

EA HINGES AS SPECIFIED IVE

1 EA PANIC DEVICE CD-18-R-P MON

2 EA IC CYLINDER AS REQUIRED BES

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA KICK PLATE 8400 10" X 2" LDW IVE

1 EA WALL STOP &

HOLDER

WS40 IVE

FUNCTION: Latchbolt retracted inside by exit device push pad and outside by key in cylinder. Door locks when key is removed and door is closed. Access from exterior when exit device push pad is dogged down.

HW SET: 21

EA HINGES AS SPECIFIED IVE

1 EA PANIC DEVICE CD-18-R-P MON

2 EA IC CYLINDER AS REQUIRED BES

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA OVERHEAD HOLDER 900H GLY

1 EA KICK PLATE 8400 10" X 2" LDW IVE

FUNCTION: Latchbolt retracted inside by exit device push pad and outside by key in cylinder. Door locks when key is removed and door is closed. Access from exterior when exit device push pad is dogged down.

HW SET: 22

EA HINGES AS SPECIFIED IVE

1 EA PANIC DEVICE CD-18-R-P MON

1138.09 – CD 08710 - 17

2 EA IC CYLINDER AS REQUIRED BES

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA OVERHEAD HOLDER 900H GLY

1 EA KICK PLATE 8400 10" X 2" LDW IVE

1 SET WEATHERSTRIP 755 REE

1 EA SWEEP 964 REE

1 EA RAIN DRIP R201 REE

1 EA THRESHOLD AS REQUIRED

FUNCTION: Latchbolt retracted inside by exit device push pad and outside by key in cylinder. Door locks when key is removed and door is closed. Access from exterior when exit device push pad is dogged down.

HW SET: 23

EA HINGES AS SPECIFIED IVE

1 EA POWER TRANSFER EPT-10 VON

1 EA PANIC DEVICE 18-R-L(NL) MON

1 EA IC CYLINDER AS REQUIRED BES

1 EA SURFACE CLOSER SC71 HD/PA DOR

1 EA HD OVERHEAD STOP 900S GLY

1 EA KICK PLATE 8400 10" X 2" LDW IVE

1 SET WEATHERSTRIP 755 REE

1 EA SWEEP 964 REE

1 EA RAIN DRIP R201 REE

1 EA THRESHOLD AS REQUIRED

NOTE: FUTURE CARD READER

FUNCTION: Latchbolt retracted inside by exit device push pad and outside by key.

HW SET: 24

EA HINGES AS SPECIFIED IVE

1 EA FIRE EXIT DEVICE F-18-R-P MON

1 EA IC CYLINDER AS REQUIRED BES

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA KICK PLATE 8400 10" X 2" LDW IVE

1 EA WALL STOP WS406CVX IVE

1 SET SMOKE GASKET 797 (AT RATED OR SMOKE & DRAFT CONTROL

DRS. ONLY)

REE

FUNCTION: Latchbolt retracted inside by exit device push pad and outside by key in cylinder. Door locks when key is removed and door is closed.

HW SET: 25

EA HINGES AS SPECIFIED IVE

1 EA POWER TRANSFER EPT-10 VON

1 EA PANIC DEVICE CD-18-R-P (LESS PULL) MON

2 EA IC CYLINDER AS REQUIRED BES

1 EA OFFSET DOOR PULL 8190-0 IVE

1 EA SURFACE CLOSER SC71 (TOP JAMB) DOR

1 EA OVERHEAD HOLDER 100H GLY

1 EA WEATHERSTRIP BY DR/FR SUPPLIER

1 EA SWEEP 964 REE

1138.09 – CD 08710 - 18

1 EA RAIN DRIP R201 REE

1 EA THRESHOLD AS REQUIRED

NOTE: FUTURE CARD READER.

FUNCTION: Latchbolt retracted inside by exit device push pad and outside by key in cylinder. Door locks when key is removed and door is closed. Access from exterior when exit device push pad is dogged down.

HW SET: 26

1 EA HINGES AS SPECIFIED IVE

1 EA POWER TRANSFER EPT-10 VON

1 EA PANIC HARDWARE ELR-18-R-P (LESS PULL) MON

1 EA IC CYLINDER AS REQUIRED BES

1 EA OFFSET DOOR PULL 8190-0 IVE

1 EA AUTO-OPERATOR 4642 LCN

1 EA OVERHEAD HOLDER 100H GLY

1 EA WEATHERSTRIP BY DR/FR SUPPLIER

1 EA SWEEP 964 REE

1 EA RAIN DRIP R201 REE

1 EA THRESHOLD AS REQUIRED

2 EA ACTUATOR 7910-956 LCN

1 EA POWER SUPPLY RDS-2 MON

1 EA WIRING DIAGRAM BY HARDWARE SUPPLIER

1 EA KEYSWITCH 653-1414-L2 LOC

NOTE: FUTURE CARD READER.

FUNCTION: Latchbolt retracted inside by exit device push pad and outside by key in cylinder. Door locks when key is removed and door is closed. This door has a power operator. Interior actuator always active to unlock and open the door. Exterior key switch will lock or unlock the door and make the exterior actuator active.

HW SET: 27

EA HINGES AS SPECIFIED IVE

1 EA PANIC DEVICE CD-18-C-DT MON

1 EA PANIC DEVICE CD-18-C-P MON

3 EA IC CYLINDER AS REQUIRED BES

2 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

2 EA KICK PLATE 8400 10" X 1" LDW IVE

2 EA WALL STOP &

HOLDER

WS40 IVE

FUNCTION: Latchbolt retracted inside by exit device push pad and outside by key in cylinder. Door locks when key is removed and door is closed.

HW SET: 28

EA HINGES AS SPECIFIED IVE

1 EA PUSH PLATE 8200 6" X 16" IVE

1 EA PULL PLATE 8303EZ-0 6" X 16" IVE

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA KICK PLATE 8400 10" X 2" LDW IVE

1 EA WALL STOP WS406CVX IVE

FUNCTION: Push / Pull.

1138.09 – CD 08710 - 19

HW SET: 29

EA HINGES AS SPECIFIED IVE

1 EA PUSH PLATE 8200 6" X 16" IVE

1 EA PULL PLATE 8303EZ-0 6" X 16" IVE

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA KICK PLATE 8400 10" X 2" LDW IVE

1 EA WALL STOP &

HOLDER

WS40 IVE

FUNCTION: Push / Pull.

HW SET: 30

EA HINGES AS SPECIFIED IVE

1 EA PUSH PLATE 8200 6" X 16" IVE

1 EA PULL PLATE 8303EZ-0 6" X 16" IVE

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA OVERHEAD HOLDER 900H GLY

1 EA KICK PLATE 8400 10" X 2" LDW IVE

FUNCTION: Push / Pull.

HW SET: 31

EA HINGES AS SPECIFIED IVE

1 EA PUSH PLATE 8200 6" X 16" IVE

1 EA PULL PLATE 8303EZ-0 6" X 16" IVE

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA HD OVERHEAD STOP 900S GLY

1 EA KICK PLATE 8400 10" X 2" LDW IVE

FUNCTION: Push / Pull.

HW SET: 32

EA HINGES AS SPECIFIED IVE

1 EA PUSH PLATE 8200 6" X 16" IVE

1 EA PULL PLATE 8303EZ-0 6" X 16" IVE

1 EA AUTO-OPERATOR 4642 LCN

1 EA OVERHEAD HOLDER 900H GLY

1 EA ARMOR PLATE 8400 36" X 2" LDW IVE

2 EA ACTUATOR 7910-956 LCN

FUNCTION: Push / Pull.

HW SET: 33

1 EA HINGES AS SPECIFIED IVE

1 EA OFFSET

PULL/PUSHBAR

9190-0 IVE

1 EA SURFACE CLOSER SC71 / SC71 HD/PA DOR

1 EA OVERHEAD HOLDER 100H GLY

FUNCTION: Push / Pull.

1138.09 – CD 08710 - 20

HW SET: 34

EA HINGES AS SPECIFIED IVE

1 EA OFFSET

PULL/PUSHBAR

9190-0 IVE

1 EA AUTO-OPERATOR 4642 LCN

1 EA OVERHEAD HOLDER 100H GLY

2 EA ACTUATOR 7910-956 LCN

FUNCTION: Push pull with handicap operator.