Amendment_4_-_KC46_Alter_Facilities_for_MX_-_Plans.pdf
PDF 14 MB Posted
- Attached to
- KC-46A Alter Facilities for Maintenance Federal contract opportunity
- Solicitation number
- W912DS18B0023
About this file
Amendment
View the file
Other files for this federal contract opportunity
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KC-46A PN163007
ALTER FACILITIES FOR
MAINTENANCE
BLDG 1817, 2201, 2251, 3101
JOINT BASE McGUIRE/DIX/LAKEHURST, NJ
ISSUE DATE: OCTOBER 2018
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S E
Y
W
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
LIGHTING FIXTURE SCHEDULE
DESCRIPTION TYPE REMARKSDRIVERLAMP VOLTAGE
/ MODEL
MANUFACTURER
H1
1598, CLASS 1 DIV 2 GROUP A,B,C,D, AND SURGE PROTECTION.
CORROSION RESISTANT, WET LOCATION RATED, UL LISTING 844,
LINEAR HAZARDOUS RATED 4FT, SEALED AND GASKETED,
APPROVED EQUAL
HOLOPHANE LIGHTING: HMRL SERIES OR
DRIVER
STANDARD
120/277
B24G1 EQUAL.
HE WILLIAMS: AT1 SERIES OR APPROVED
A24G2 CLEAR ACRYLIC #19 0.156 THICK, STANDARD T-GRID CEILING
RECESSED 2' X 4' LENSED TROFFER WHITE FLAT STEEL DOOR,
A22G 277
X
DIRECTION AS SHOWN ON DRAWINGS.
DOUBLE FACE, WHITE FINISH, AC ONLY, GREEN TEXT, CHEVRON
LED UNIVERSAL MOUNT EXIT LIGHT, ALUMINUM WITH SINGLE OR LITHONIA LE SERIES OR APPROVED EQUAL.
LED 120/277
SUPPORT FROM STRUCTURE
1. LUMINAURE MANUFACTURER AND MODELS ARE BASIS OF DESIGN. PROVIDE LUMINAIRES TO MATCH OR EXCEED LUMEN/WATT EFFICIENCY.
NOTES:
924 LISTED.
2. PROVIDE LUMINAIRES WITH AN 'E' SUFFIX WITH A MINIMUM 90 MINUTES OF BATTERY BACKUP WITH FULL BATTERY POWER OUTPUT AND UL
D2
3500K
LUMENS
LED 500
277EQUAL.
HE WILLIAMS LSL60 SERIES OR APPROVED
C1 120/277
A14
EQUAL.
HE WILLIAMS 80 SERIES OR APPROVED
D1 277EQUAL.
HE WILLIAMS L60 SERIES OR APPROVED
3500K
LUMENS
LED 1700
A24F3 277
SUSPEND AT 14FT AFF
LUMENS
LED 8000
EQUAL.
HE WILLIAMS: 50 STATIC SERIES OR APPROVED
3500K
LUMENS
LED 5900
DRIVER
0-10V DIMMING
BACKUP.
TYPE 'A24F2E' SAME AS TYPE 'A24G2' WITH FLANGE KIT AND BATTERY
TYPE 'A24F2' SAME AS TYPE 'A24G2' WITH FLANGE KIT.
BACKUP.
TYPE 'A24G2E' SAME AS TYPE 'A24G2' WITH INTEGRAL BATTERY
WITH MATT ACYLIC CENTER, STANDARD T-GRID CEILING
RECESSED 2' X 4' PERFORATED CURVED BASKET DIRECT/INDIRECT
CLEAR ACRYLIC #19 0.156 THICK, WITH FLANGED KIT
RECESSED 2' X 4' LENSED TROFFER WHITE FLAT STEEL DOOR,
EQUAL.
HE WILLIAMS: 50 STATIC SERIES OR APPROVED
3500K
LUMENS
LED 5900
DRIVER
0-10V DIMMING
CLEAR ACRYLIC #19 0.156 THICK, STANDARD T-GRID CEILING
RECESSED 2' X 2' LENSED TROFFER WHITE FLAT STEEL DOOR,
EQUAL.
HE WILLIAMS: 50 STATIC SERIES OR APPROVED
3500K
LUMENS
LED 2600
DRIVER
0-10V DIMMING
TYPE 'A22F' SAME AS TYPE 'B1G' WITH FLANGE KIT.
TYPE 'A22E' SAME AS TYPE 'B1' WITH INTEGRAL BATTERY BACKUP
3500K
LUMENS
LED 3000
DRIVER
0-10V DIMMING
REFLECTOR AND WIRE GUARD WITH HANGING ASSEMBLY.
INDUSTRIAL 4 FOOT, STANDARD DUTY, STEEL WHITE P0WDER COAT
4000K
LUMENS
LED 6300
DRIVER
STANDARD
CLEAR LENS
SURFACE MOUNTED 4FT ROUGH SERVICE VANDAL RESISTANT WRAP
WRAP SERIES OR APPROVED EQUAL.
HE WILLIAMS: AVX ARCHITECTURAL VANDAL
4000K
LUMENS
LED 6200
DIMMING DRIVER
CLEAR SPECULAR REFLECTOR, WHITE TRIM FLANGE.
6" DIAMETER APERTURE BY 8" DEPTH RECESSED DOWNLIGHT,
RATED UNDER COVER.
CONFORMS TO UL STD 1598 AND SUITABLE FOR WET LOCATION
DOWNLIGHT, CLEAR SEMI SPECULAR REFLECTOR, cETLus
SHOWER LIGHT 6" DIAMETER APERTURE BY 7-3/4" DEPTH RECESSED
DRIVER
STANDARD
DRIVER
STANDARD
'B24G1E' SAME AS TYPE 'B24G1' WITH INTEGRAL BATTERY BACKUP
B24G2 EQUAL.
HE WILLIAMS: AT1 SERIES OR APPROVED
277WITH MATT ACYLIC CENTER, STANDARD T-GRID CEILING
RECESSED 2' X 4' PERFORATED CURVED BASKET DIRECT/INDIRECT
3500K
LUMENS
LED 4000
DRIVER
0-10V DIMMING
'B24G2E' SAME AS TYPE 'B24G2' WITH INTEGRAL BATTERY BACKUP
B14F 277WITH MATT ACYLIC CENTER, WITH FLANGED KIT
RECESSED 1' X 4' PERFORATED CURVED BASKET DIRECT/INDIRECT
EQUAL.
HE WILLIAMS: AT1 SERIES OR APPROVED
3500K
LUMENS
LED 2000
DRIVER
0-10V DIMMING
'B14FE' SAME AS TYPE 'B14F' WITH INTEGRAL BATTERY BACKUP
'D1E' SAME AS TYPE 'D1' WITH INTEGRAL BATTERY BACKUP
'C1E' SAME AS TYPE 'C1' WITH INTEGRAL BATTERY BACKUP
E L E
C T
R
IC
A L
L
IG
H T
IN
G F
IX
T U
R E S
C H
E D
U L
E-601
FOR CONSTRUCTION
A
M c
W H
O R
T E
R
S
G R
A H
A M
R J
O H
N S
O N
G
R
IG
G
IN
S
P T F
L -1
-0
-E -6
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
UL924 DEVICE
OCCUPANCY SENSOR
NORMAL POWER
EMERGENCY POWER
NORMAL LIGHTING
EMERGENCY LIGHTING
NORMAL POWER SENSE
NORMAL SWITCHING SIGNAL
ON/OFF WITH NORMAL
EMERGENCY ON
A2
EMERGENCY LTG CONTROL DETAIL
SCALE: NTS
CEILING MOUNT
SENSOR
Room
Controller
J-BOX
SWITCH
120VACPLUG LOAD
CONTROLLER
LINE VOLTAGE
LOADS
J-BOX
A6
SWITCHED RECEPTACLE DETAIL
SCALE: NTS
LOADSLOADS
1 2
A M
E N
D M
E N
T
-1
-1
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
-O
C T -2
:5
T E
L E
C O
M M
U N
IC
A T
IO
N S
D E
T A
IL
S
T-501
M C
C A
L L
S
G R
A H
A M
J
H U
R S
O N
G
R
IG
G
IN
S
P T F
L -1
-0
-T -5
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
T
E L E
C O
M M
U N
IC
A T
IO
N S R
O O
M R
E L
O C
A T
IO
N -1
(OFFICES, X-RAY SPACES)
TYPICAL WORK AREA OUTLET
ELEC/COMM ROOM 120
EXISTING FLOOR
(TYPICAL)
9. EXISTING RUNWAY CABLE TRAY.
THE CABLE TRAY SYSTEM.
8. PROVIDE CABLE WATERFALL BEND RADIUS SUPPORTS WHERE CABLING LEAVES
7. PROVIDE INSULATED THROAT BUSHINGS AT ENDS OF ALL CONDUITS.
PULL BOX INDICATED ON PLANS.
OUTLETS; EXTEND UP TO ABOVE CEILING AND TURN HORIZONTAL TO EXTEND TO
6. PROVIDE 1 IN CONDUIT FOR ALL WALL-MOUNTED TELECOMMUNICATIONS
WIRING BLOCKS FOR RJ45 PORTS.
5. EXTEND CABLING TO EXISTING PATCH PANELS AND TERMINATE ON EXISTING
4. PROVIDE PULL BOX OF TYPE INDICATED ON PLAN DRAWINGS.
3. DENOTES EXISTING TELECOM RACK IN COMM ROOM 122.
INDICATES SIX (6) TYPE UKP60 CABLES.
QUANTITIES GREATER THAN ONE. FOR EXAMPLE, CABLE DESIGNATION (6)UKP60
B. NUMBERS IN PARENTHESIS BEFORE CABLE DESIGNATIONS REFER TO CABLE
AND SPECIFICATIONS.
A. REFER TO LEGEND, TELECOMMUNICATIONS OUTLET & CABLING SCHEDULES,
DRAWINGS. ADDITIONAL REQUIREMENTS:
SCHEDULE FOR THE TELECOMMUNICATIONS OUTLETS INDICATED ON PLAN
TERMINATION PROVISIONS AS REQUIRED BY THE TELECOMMUNICATIONS OUTLET
2. PROVIDE QUANTITY AND ARRANGEMENT OF OUTLETS, CABLE HOME RUNS, AND
TELECOMMUNICATIONS SYSTEM RISER DIAGRAMS.
1. REFER TO GENERAL NOTES FOR ADDITIONAL REQUIREMENTS THAT PERTAIN TO
SHEET KEYNOTES - BLDG 2201
B6
TELECOMMUNICATIONS DIAGRAM - BLDG 2201
SCALE: NTS
7 4
ASSUME EXISTING CABLE IS 24 STRAND MULTIMODE; VERIFY WITH CONTRACTING OFFICER'S REPRESENTATIVE.
RE-ROUTE EXISTING FIBER CABLE SERVING EXISTING CABINET INDICATED ON DEMOLITION PLAN TO THE TELECOMMUNICATIONS RACK IN ROOM 150. TERMINATE AND TEST ON FIBER PANEL INDICATED. 16.
PROVIDE 4 IN X 4 IN X 2 IN MODULAR FURNITURE CABLING JUNCTION BOX WITH COVERPLATE AND OPENING FOR THE FLEXIBLE METAL CONDUIT INDICATED.15.
PROVISIONS WITH THE CONTRACTING OFFICER'S REPRESENTATIVE PRIOR TO INSTALLATION.
EXTEND CABLING TO NEW PATCH PANELS INDICATED AND TERMINATE ON WIRING BLOCKS FOR RJ45 PORTS; VERIFY EXACT PATCH PANEL PORT CONNECTION LOCATION AND RELATED CABLING 14.
PROVIDE CABLE WATERFALL BEND RADIUS SUPPORTS WHERE CABLING LEAVES THE CABLE TRAY SYSTEM.13.
ON PLANS.
PROVIDE 1-1/4 IN CONDUIT RISER FOR MODULAR FURNITURE CABLING JUNCTION BOXES; EXTEND UP TO ABOVE CEILING AND TURN HORIZONTAL TO EXTEND TO RAIL OF CABLE TRAY SYSTEM INDICATED 12.
VERIFY MOUNTING AND EXACT LOCATIONS OF ALL NEW RACK EQUIPMENT WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.11.
VERIFY FLOOR BOX AND POKE-THRU OUTLET MOUNTING WITH CONTRACTING OFFICER'S REPRESENTATIVE PRIOR TO INSTALLATION.
TELECOMMUNICATIONS OUTLET MOUNTING ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION, INCLUDING BUT NOT LIMITED TO FACEPLATES, BRACKETS, AND ALL REQUIRED HARDWARE.
REFER TO ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR FLOOR BOXE AND POKE-THRU REQUIREMENTS, ALONG WITH RELATED WORK PERTAINING TO PROVISION OF CONDUITS. PROVIDE ALL 10.
PROVIDE CABLE TRAY OF TYPE INDICATED ON PLAN DRAWINGS FOR CABLING. REFER TO CABLE TRAY SCHEDULE FOR ADDITIONAL REQUIREMENTS.9.
TRANSITION POINT DETAIL DRAWING.
TRANSITION POINT TO ACCOMPLISH TRANSITION FROM OUTDOOR/OSP CABLING EXTENDED TO SLAB-ON-GRADE. FLOOR BOX TO PLENUM-RATED CABLING TO COMM ROOM INDICATED. REFER TO 8.
PROVIDE INSULATED THROAT BUSHINGS AT ENDS OF CONDUITS.7.
PLANS.
PROVIDE 1 IN CONDUIT RISER FOR WALL-MOUNTED TELECOMMUNICATIONS OUTLETS; EXTEND UP TO ABOVE CEILING AND TURN HORIZONTAL TO EXTEND TO EDGE OF CABLE TRAY SYSTEM INDICATED ON 6.
FOR SLAB-ON-GRADE FLOOR BOXES, PROVIDE TRANSITION POINTS INDICATED. REFER TO TRANSITION POINT DETAIL DRAWINGS.5.
ENCLOSURE WITH COMPRESSION LUGS. REFER TO ELECTRICAL DRAWINGS FOR PANELBOARD LOCATIONS.
PROVIDE #1/0 AWG INSULATED COPPER GROUND IN 1 IN CONDUIT TO BOND TELECOMMUNICATIONS SYSTEM GROUND BUS TO THE STRUCTURAL STEEL AND TO NEAREST ELECTRICAL PANELBOARD 4.
PROVIDE #4 AWG INSULATED COPPER GROUND TO BOND CABINET TO THE TELECOMMUNICATIONS SYSTEM GROUND BUS.3.
B. NUMBERS IN PARENTHESIS BEFORE CABLE DESIGNATIONS REFER TO CABLE QUANTITIES GREATER THAN ONE. FOR EXAMPLE, CABLE DESIGNATION (6)UKP60 INDICATES SIX (6) TYPE UKP60 CABLES.
A. REFER TO LEGEND, TELECOMMUNICATIONS OUTLET & CABLING SCHEDULES, AND SPECIFICATIONS.
TELECOMMUNICATIONS OUTLETS INDICATED ON PLAN DRAWINGS. ADDITIONAL REQUIREMENTS:
PROVIDE QUANTITY AND ARRANGEMENT OF OUTLETS, CABLE HOME RUNS, AND TERMINATION PROVISIONS AS REQUIRED BY THE TELECOMMUNICATIONS OUTLET SCHEDULE FOR THE 2.
REFER TO GENERAL NOTES FOR ADDITIONAL REQUIREMENTS THAT PERTAIN TO ALL TELECOMMUNICATIONS SYSTEM RISER DIAGRAMS.1.
SHEET KEYNOTES - BLDG 3101
(RU)
(IN)
TGB
WALL
CEILING
SUSPENDED
PATCH PANEL-DATA DL48
WIRE MGMT-HORIZ MH2
PATCH PANEL-DATA DL48
WIRE MGMT-HORIZ MH2
BLANK BP1
BOX OUTLET
TYPICAL FLOOR
PATCH PANEL-DATA DL48
WIRE MGMT-HORIZ MH2
SYSTEM (BY OTHERS)
MODULAR FURNITURE
AND COVER PLATE
SYSTEM OUTLET BOX
MODULAR FURNITURE
COMPARTMENT - FOR DATA CABLING
MODULAR FURNITURE PATHWAY CF44
(OFFICES, CONF ROOMS, ETC.)
TYPICAL WORK AREA OUTLET
BL1BLANK
FCM24FIBER PANEL
"3101-D"
CABINET
A1
TELECOMMUNICATIONS DIAGRAM - BLDG 3101
SCALE: NTS
6 11
TYP
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
CABLE TRAY
SPACING
5 FT MAXIMUM, @
1 IN G ROD
CONDUIT TO TRY.
AND BUSHING. BOND
USE 1 IN CONNECTOR
DRY WALL
CEILING
GYPSUM SUSPENDED
1 IN CONDUIT
AND BUSHING
CONNECTOR
1 IN BOX
BACK BOX
4 IN x 4 IN x 2 IN
WALLWORK AREA
FLOOR BOX
CONCRETE SLAB
ROOM
TELECOMMUNICATIONS
FLOOR BOX TO PULLBOX)
MAX DISTANCE FROM
OUTDOOR CABLE (15 m
CAT 6A INDOOR/
CONDUIT
RGS
CEILING
OFFICE FLOOR BOX
RUN IN CABLE TRAY.
IN CONDUIT. DO NOT
CABLE SHALL BE RUN
INDOOR/OUTDOOR
NOTE:
REFER TO DETAIL 8.
TRANSITION POINT.
CATEGORY 6 UTP CABLE, PLENUM.4.
PLANT RATED
CATEGORY 6 UTP CABLE, OUTDOOR/OUTSIDE 3.
CATEGORY 6 110 WIRE BLOCK.2.
COVER.
16 IN X 8 IN X 4 IN. ENCLOSURE, WITH SCREW 1.
23 4
E3
TYPICAL OUTLET DROP
SCALE: NTS
E1
CABLE ROUTING
E6
DETAIL
TRANSITION POINT
CONDUIT
RGS
A6
BOXES AND RACEWAY SYSTEM ONLY
TYPICAL - CARD READER STATION-
CONT
DOOR
E
I
SECURE SIDE
PUBLIC SIDE
CEILING
K
G
F
C
A
B
J
H
JB
M
N D
DOOR WIRING
L
P
J*
GOVERNMENT'S SECURITY CONTRACTOR.
REPRESENTATIVE FOR DOOR CONTROLLER BY
DIRECTED BY CONTRACTING OFFICER'S
ROOM, EXTEND TO TELECOM ROOM LOCATION
1" MINIUMUM CONDUIT TO NEAREST TELECOM
-O
C T -2
:5
T E
L E
C O
M M
U N
IC
A T
IO
N S
D E
T A
IL
T-508
M C
C A
L L
S
G R
A H
A M
J
H U
R S
O N
G
R
IG
G
IN
S
P T F
L -1
-0
-T -5
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
T
E L E
C O
M M
U N
IC
A T
IO
N S R
O O
M R
E L
O C
A T
IO
N -1
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
-O
C T -2
:2
T E
L E
C O
M M
U N
IC
A T
IO
N S
E Q
U
IP
M E
N T S
C H
E D
U L
T-601
M C
C A
L L
S
G R
A H
A M
J
H U
R S
O N
G
R
IG
G
IN
S
P T F
L -1
-0
-T -6
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
T
E L E
C O
M M
U N
IC
A T
IO
N S R
O O
M R
E L
O C
A T
IO
N -1
TA
SK
O R
D
ER
N O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
US Army Corps of Engineers
U .S
.A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
N
EW
Y O
R K
D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
N
EW
Y
O R
K, N
Y
SC
AL
E:
SH
EE
T
D R
AW
IN
G C
O D
E:
O F
KC
-4
6A B
ED
D
O W
N M
C G
U
IR
E
AF
B
BU
R
LI
N G
TO
N
C O
U N
TY
, N
EW
J
ER
SE
2E R
-1 4-
D -0
SE
PT
EM
BE
R
AN
SI
D 1:
L
AK
ES
ID
E C
EN
TR
E W
AY
SU
IT
E
KN
O
XV
IL
LE
, T
N
$P
LO
TD
AT
E $P
LO
TT
IM
E
IN
TE
R
IO
R S
IN
TE
R
IO
R C
O
LO
R
AN
D F
IN
IS
H S
C H
ED
U
LE
IN601
FOR CONSTRUCTION
K.
C
O R
BE
TT
M . E
R R
AZ
O
J.
M
IL
LE
R
G . R
IG
G
IN
S
PT
FL
-1
-2
1-
IN
1.
dw g
IS
SU
E
FO
R C
O N
ST
R
U C
TI
O
N
-2 7-
AM
EN
D M
EN
T
-1
0-
M. Johnson Stamp
2 3
G
F
E
D
B
A
I
__ -=tJ ____ -
I ' I ' I
" i " I
I " I
I ' I l2:
I I -
II
>=n
I X I
I ll,I\JII I
II
5 6 7 8
0Li @ @@ I
I ������--r s:_:;:;;;;;;:;:::;_ -�-�-��-�-��-��' 'jj ' o o I !CD(E)! 170 !
I 1¢D-rnl35ol
TYP.4
I BREAK ROOM I ' [@] '
_! ____ _cl I ' t-L--1--
II
MPO
[Jfil
ELEC./
400 HZ.
ugl_
ENLARGED FIRST FLOOR HVAC PLAN - NON-DESTRUCTIVE ANALYSIS
C5 I-S-CA-LE-• -1ffi-"-1�'-0�"
------"------'"-'-------"-----;._-__,;,.._..;....a _____ .;....;'-----
�t ��"""'-� ENLARGED PLAN C3, THIS SHEET, FOR CONT
I
I G G
DSD
I
D2
0J)
TYP.4
l(EB\ M�01 il__F@ � \ 0) 0'>
�( •)(•J ,;,,. p "A" '(·)0 "' "' <X) I x � '
---- AHU-2-2
\ x j �
I
,v \ �1 �·
ACU-2-1
-I- + D , . L,_ / I �
TURNING VAL:S TYP. ,t- � r
1"-HWS/Rt-r
"'---- 'i
�� C)� <...00 -n ---:u---- I
,------<\---1' I>-- 1 "-(:;WS/R
i ii
� ;r
I/
( MAINTENANCE & co� v 12x6 '\ \ �L]ll:!�NCE
¼0 &--r- I 0 u u
(E) 4"-LPS
(E)4"-HWR
(E)4"-HWS
{t:.) 11/4"-vrivvr..
(E) 11/4"-CHWS
(� I ,.
i 1,P-"'-�-f( ':-,✓.?: : �
' rt 1"-H)"S/R � 'I-� i
- 7 r
12x8
1 1/4"-CYf/R
I I
�-1Jr� -MAI ENANCE & CPIL
PULUCLEARANCE
.I - -
I
--t---------------+------------ , , 0 0
I
\1 --------=�-:tr--e---0 I I
ENLARGED MEZZANINE HVAC PLAN - NON DESTRUCTIVE ANALYSIS
9 10
GENERAL SHEET NOTES
A. SEE SHEET M-001 FOR SYMBOLS, ABBREVIATIONS AND
GENERAL NOTES.
B. DUCT INSULATION NOT SHOWN THIS PLAN. INSULATE IN
ACCORDANCE WITH 23.
C. DUCT HANGERS NOT SHOWN THIS PLAN. SUSPEND DUCT PER 23.
D. PIPE SUPPORTS NOT SHOWN THIS PLAN. INSTALL PER 23.
0 SHEET KEYNOTES
1. INSTALL NEW AIR HANDLING UNITS ON EXIST. CONCRETE PADS
PROVIDE ADDITIONAL CONCRETE TO 4" GREATER THAN UNIT
DIMENSIONS AND 2" TOERAIL. DO NOT COVER EXISTING FLOOR
DRAINS.
2. CONNECT UNITS TO EXIST. HW SUPPLY AND RETURN.
3. CONNECT UNITS TO EXIST. CHW SUPPLY AND RETURN.
4. CONNECT NEW CHW BRANCH PIPING TO MAINS AND EXTEND TO
UNIT.
5. DROP DUCT DOWN THRU ROOF OF EXIST VAULT. PROVIDE OPEN
IN ROOF.
6. DROP DUCTS DOWN AS CLOSE TO WALL AS POSSIBLE. INSTALL
HORIZONTAL RUNS ON TOP OF NEW ADDITION.
7. DROP DUCT DOWN THROUGH CAP INTO CEILING OF NEW ROOM
ADDITION.
8. DROP DUCT DOWN APPROXIMATELY 18" BOTTOM OF DUCT
ABOVE NEW CEILING.
9. SEE ENLARGED PLAN A4 ON THIS SHEET FOR CONTINUATION.
10. MOUNT DUCT SMOKE DETECTOR (DSD) IN ACCESSIBLE LOCATION
IN SUPPLY DUCT OF ACU-2-1 ONLY.
11. ROUTE 3/4" CONDENSATE DRAIN FROM COIL DRAIN PAN
CONNECTION TO EXISTING FLOOR DRAINS LOCATED
IMMEDIATELY IN FRONT OF COOLING COILS. REFER TO DETAIL
EI-MH-501 FOR P-TRAP DETAIL.
12. 8"x8" EXHAUST AIR FROM PROCESSING. LOCATE EXHAUST FAN IN
ACCESSIBLE LOCATION ABOVE ROOM CAP. ROUTE DUCT UP AND
DISCHARGE TO ATMOSPHERE OUT SIDEWALL ABOVE LOW ROOF
VIA 12"x12" DISCHARGE LOUVER.
KEY PLAN
GRAPHIC SCALE
4' 8' 16'
2' 4' 8'
US Army Corps of Engineers ®
"z oO "" t-0 z::, w"' :J � "z �8 w"' <J) 0 z � i� � �
N - 0 � " ci uj � z ci □ �" "' z 0 Q ,w t- "
I 0 w " t- WO ::, ,,, z wo ,,, ;, 0 ��!!2 " □
>' � 0":"': a:l...J .. □ "'-□� >- w �i ffi � z >- □S2.,: ;:o o" "'" �� �� �� W . □w □□ ,,,, ,,,., iw w z
�� � ei z w
"->- z
0 JZ
�"' w' w"'
-5� ::J
0 □o " w>- �>- �� 0 " '.'i z "' " "' z � <C z ;: _J
� w _J 0.
z <C u □ r:: ,2 <C ii] z> z <CI "' => ;\I
0 Io " Uw
0 z W(!)
0 :;;Cl'. "
<C z _J z
::, w
SHEET ID
"' SCALE•1/4"-1'-0"
MH401
iL _________________________________________________________________________________________________________ L ________________ .l_ ..... :::.::::.::::::::::._...JL.::======::.J
X
T E
N T S O
F M
E Z
Z A
N
IN
E w
R E
S T
R O
O M D
E M
O
B
O V
E
(NO WORK THIS AREA)
EXISTING WAREHOUSE
E X
IS
T
IN
G F
IR
E W
A L L B
E T
W E
E N U
N
IT
S
A P
P R
O X
IM
A T
E E
X T
E N
T S O
F R
E S
T R
O O
M D
E M
O
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
KEY PLAN
GRAPHIC SCALE
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
UNIT- A UNIT- B UNIT- C UNIT- D UNIT- E
N
G
H
F
E
D
53 54 55
10 10
11 12
GENERAL SHEET NOTES
LEGEND
SHEET KEYNOTES
TYP
-O
C T -2
:5
D E
M O
L
IT
IO
N
A R
C H
IT
E C
T U
R A
L
F
IR
S T F
L O
O R D
E M
O L
IT
IO
N P
L A
N A
R E
A B
AD102
FOR CONSTRUCTION
M J
O H
N S
O N
J .O
C A
S
IO
S A
N G
E R
H A
U S
E N
G
R
IG
G
IN
S
P T F
L -1
-3
-A
D .d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
T
E L E
C O
M M
U N
IC
A T
IO
N S R
O O
M R
E L
O C
A T
IO
N -1
A1
FIRST FLOOR DEMOLITION PLAN - UNIT E - AREA B
SCALE: 3/16" = 1'-0"
8'0 4' 16'
1. NOT USED.
2. EXISTING INTERIOR CONSTRUCTION TO REMAIN (N.I.C.)
3. DEMO EXISTING RESTROOM(S),OFFICE, STORAGE, MECHANICAL
RM
4. DEMO RESTROOMS FIXTURES AND ACCESSORIES
5. DEMO MOP SINK
6. DEMO STAIR AND WOMEN RESTROOM ABOVE MEN RESTROOM
7. DEMO EXISTING WASH SINK AND ASSOCIATED PLUMBING
8. DEMO INTERMEDIATE WALL BETWEEN (2) ROOMS.
9. DEMO (2) EXISTING WOOD DOORS.
10. DEMO ACT CEILING.
11. REMOVE FLOORING.
12. REMOVE BASE.
FOR ADDITIONAL INFORMATION.
EXISTING BELOW SLAB PLUMBING. RE: PLUMBING DRAWINGS
SLAB PLUMBING AND AS NECESSARY TO REMOVE AND CAP
DEMO PORTION OF CONCRETE FLOOR SLAB AT NEW BELOW B.
HVAC, FIRE PROTECTION, AND ASSOCIATED FINISHES.
ACOUSTICAL CEILINGS, RELATED LIGHTING, POWER/DATA,
GWB INTERIOR PARTITION WALLS, DOORS AND FRAMES,
DEMO EXISTING RESTROOM AREA, INCLUDING CMU OR STUD & A.
B
EXISTING CONSTRUCTION
DEMOLITION WALL
DEMOLITION DOOR
A7
PARTIAL DEMOLITION PLAN - UNIT E - NEW TELECOM RM
SCALE: 3/16" = 1'-0"
D
F
G
H
J
K
L
T
53 6554 55 56 57 58 59 60 61 62 63 64
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
UNIT- A UNIT- B UNIT- C UNIT- D UNIT- E
N
-O
C T -2
:5
D E
M O
L
IT
IO
N
E L E
C T
R
IA
L
F
IR
S T F
L O
O R D
E M
O L
IT
IO
N P
O W
E R P
L A
N O
V E
R A
L L
ED110
FOR CONSTRUCTION
A
M c
W H
O R
T E
R
S
G R
A H
A M
R J
O H
N S
O N
G
R
IG
G
IN
S
P T F
L -1
-3
-E
D .d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
P R
O J E
C T -N
O
B1
FIRST FLOOR DEMOLITION PLAN - OVERALL
SCALE: 3/32" = 1'-0"
0 8' 32'16'
EQUIPMENT TO REMAIN.
CONSTRUCTION. RELOCATE AND EXTEND CIRCUIT FOR
SERVING OR IN CONFLICT WITH THE DEMOLITION AND NEW
ASSOCIATED EQUIPMENT, DEVICES, CONDUIT, AND CIRCUITS
FOR DEMOLITION ITEMS. COORDINATE AND REMOVE
REFER TO ARCHITECTURAL, MECHANICAL, AND PLUMBING PLANS E.
WORK.
SPARE. UPDATE CIRCUIT DIRECTORY FOR DEMOLITION AND NEW
DEMOLISHED TURN CIRCUIT BREAKER TO 'OFF' AND LABEL AS
CONNECTED TO CONDUCTORS. WHERE CIRCUITS ARE
TURN 'OFF' SPARE CIRCUIT BREAKERS THAT ARE NOT D.
CONDUCTORS.
DEMOLITION AND REMOVE ABANDON CONDUIT AND C.
REUSED.
AFTER COMPLETION OF WORK AND WHERE CONDUCTORS ARE
TEST INTEGRITY OF EXISTING CIRCUITS PRIOR TO WORK AND B.
NOTED.
ELECTRICAL EQUIPMENT IS EXISTING UNLESS OTHERWISE A.
GENERAL SHEET NOTES
SHEET KEYNOTES
DEVICES OUTSIDE OF THE ROOM ARE CONNECTED TO CIRCUIT.
CIRCUIT BACK TO PANEL AND LABEL SPARE WHERE NO OTHER
BACK TO NEAREST JUNCTION BOX OUTSIDE OF ROOM. REMOVE
REMOVE LIGHTING FIXTURES, CONTROLS, AND RECEPTACLES 5.
OF WORK AND AT COMPLETION.
EXISTING CONDITIONS. TEST TRANSFORMER PRIOR TO START
FROM TRANSFORMER 'C' SERVING THE EAST BAY. COORDINATE
REMOVE EXISTING SECONDARY SERVICE ENTRANCE FEEDERS 4.
COMPLETION.
CIRCUIT BREAKERS PRIOR TO START OF WORK AND AT
COORDINATE EXISTING CONDITIONS. TEST PANELS AND
REMAIN TO FEED FROM NEW DISTRIBUTION PANEL.
SERVICE BONDING JUMPERS TO PANELS. EXISTING PANELS TO
TRANSFORMER 'C' FEEDING THE EAST BAY. REMOVE EXISTING
SERVICE ENTRANCE PANELS BACK TO SERVICE ENTRANCE
DEMOLISH EXISTING SERVICE ENTRANCE CONDUCTORS TO 3.
MECHANICAL EQUIPMENT DEMOLITION FOR COORDINATION.
BACK TO PANEL. REFER TO MECHANICAL PLANS FOR
MECHANICAL EQUIPMENT CONNECTIONS. REMOVE CIRCUITS
REMOVE LIGHTING FIXTURES, CONTROLS, RECEPTACLES, AND 2.
NEW WORK.
ASSOCIATED CIRCUITS FROM ROOM. MAINTAIN CIRCUITS FOR
REMOVE LIGHTING FIXTURES, CONTROLS, RECEPTACLES, AND 1.
"EFPANEL "
EXISTING
"CPANEL "
EXISTING
"DPANEL "
EXISTING
"5EPANEL "
EXISTING
"7EPANEL "
EXISTING
3/32" = 1'-0"
T E
L E
C O
M M
U N
IC
A T
IO
N R
O O
M R
E L
O C
A T
IO
N -1
:1
6563615957
H
L
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
UNIT- A UNIT- B UNIT- C UNIT- D UNIT- E
N
-O
C T -2
:5
D E
M O
L
IT
IO
N
T E
L E
C O
M M
U N
IC
A T
IO
N S
F
IR
S T F
L O
O R D
E M
O L
IT
IO
N P
L A
N A
R E
A A
TD111
FOR CONSTRUCTION
W
M C
C A
L L
S
G R
A H
A M
J
H U
R S
O N
G
R
IG
G
IN
S
P T F
L -1
-3
-T
D .d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
T
E L E
C O
M M
U N
IC
A T
IO
N S R
O O
M R
E L
O C
A T
IO
N -1
O J E
C T -N
O
GENERAL SHEET NOTES
SHEET KEYNOTES
B1
FIRST FLOOR TELECOMMUNICATIONS DEMOLITION PLAN - AREA A
SCALE: 1/8" = 1'-0"
0 8'4' 16'
ROOM 150 IN CABLE TRAY SYSTEM INDICATED ON DWG T-401.
CABINET OVER TO NEW TELECOMMUNICATIONS CABINET IN
CABINET AND REROUTE EXISTING FIBER SERVICE CABLE TO
REMOVE EXISTING WALL-MOUNTED TELECOMMUNICATIONS 2.
TELECOMMUNICATIONS ROOM SERVING THIS AREA.
BACK TO THE TERMINATION POINT IN THE
ALONG WITH ALL AND RELATED CABLING INFRASTRUCTURE
DATA OUTLETS AFFECTED BY THE PARTITION DEMOLITION,
TO BE DEMOLISHED IN THIS AREA, REMOVE THE 20 EXISTING
FOR THE PARTITIONS INDICATED ON THE ARCHITECTURAL PLANS 1.
EQUIPMENT, OUTLET, AND CABLING SCHEDULES.
REFER TO DRAWINGS T-601 AND T-602 FOR TELECOMMUNICATIONS B.
LEGEND AND ABBREVIATIONS.
REFER TO DRAWING T-001 AND T-002 FOR TELECOMMUNICATIONS A.
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
LIFE SAFETY CODE ANALYSIS LIFE SAFETY CODE ANALYSIS - CONTINUED LIFE SAFETY CODE ANALYSIS - CONTINUED -O
C T -2
:2
A R
C H
IT
E C
T U
R A
L
C O
D E A
N A
L Y
IS
A-010
FOR CONSTRUCTION
B P
E A
B O
D Y
M E
R R
A Z
O
S A
N G
E R
H A
U S
E N
G
R
IG
G
IN
S
P T F
L -1
-3
-A -0
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
A
M E
N D
M E
N T
-0
1. PROJECT NAME KC-46A BEDDOWN, ALTER
FACILITIES FOR MAINTENANCE
APPLICABLE CODES AND STANDARDS
NFPA 1 THE FIRE CODE, (2018 EDITION)
NFPA 10 STANDARD FOR PORTABLE FIRE
EXTINGUISHERS (2017 EDITION)
NFPA 13, STANDARD FOR THE INSTALLATION OF
SPRINKLER SYSTEMS (2016 EDITION)
NFPA 30 FLAMMABLE AND COMBUSTIBLE LIQUIDS
CODE, 2015
NFPA 70 NATIONAL ELECTRICAL CODE (NEC) (2017
EDITION)
NFPA 72 NATIONAL FIRE ALARM CODE (2016 EDITION)
NFPA 101 LIFE SAFETY CODE (LSC) (2015 EDITION),
NFPA 101 MUST BE UTILIZED TO DETERMINE
OCCUPANCY CLASSIFICATION AS IT RELATES
TO FIRE/SMOKE RESISTANCE RATING OF
INTERIOR NON-LOAD BEARING PARTITIONS
(OTHER THAN OCCUPANCY SEPARATION),
MEANS OF EGRESS, INTERIOR FINISH,
FEATURES OF FIRE PROTECTION (INCLUDING
VERTICAL OPENINGS) AND ASSOCIATED
REQUIREMENTS.
NFPA 291 FIRE FLOW TESTING (2016 EDITION)
NFPA 720 STANDARD FOR THE INSTALLATION OF
CARBON MONOXIDE (CO) DETECTION AND WARNING
EQUIPMENT, 2015
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR
FACILITIES (08 AUGUST 2016, CHANGE 1 28,
NOVEMBER 2016)
UFC 4-010-01 DOD MINIMUM ANTITERRORISM
STANDARDS FOR BUILDINGS 9 FEBRUARY
2012; CHANGE 1 1 OCTOBER 2013.
UFC 4-021-01 DESIGN AND O & M MASS
NOTIFICATION SYSTEMS (9 APRIL 2018,
CHANGE 1 JANUARY 2010)
IBC, 2015 INTERNATIONAL BUILDING CODE (IBC
SHALL BE USE D FOR CONSTRUCTION
REQUIREMENTS; LIFE SAFETY CODE [LSC]
SHALL BE USED FOR ALL MEANS OF EGRESS
REQUIREMENTS, AS REQUIRED BY UFC
1-200-01 AND UFC 3-600-01.)
FIRE PROTECTION ENGINEER OF RECORD:
OF THE FIRE PROTECTION AND LIFE SAFETY FEATURES FOR THIS PROJECT.
PREPARERS OF THIS DOCUMENT CERTIFY THE ACCURACY AND COMPLETENESS
CERTIFICATION OF FIRE PROTECTION AND LIFE SAFETY CODE REQUIREMENTS.
Bruce V Peabody P.E
2. OCCUPANCY CLASSIFICATION
IBC CHAPTERS 3 AND 4
3101 MIXED USE: STORAGE S-1, BUSINESS B
3. CONSTRUCTION TYPE
NFPA 415, CHAPTER 4
3101 EXISTING TYPE II B
4. AREA LIMITATIONS
IBC CHAPTER 5, 505.2.1.
EXISTING CONDITIONS,
AREA OF BUILDING IS NOT INCREASING.
MIXED USE AND OCCUPANCY SEPARATIONS
IBC 505.2.3 IBC 508, TABLE 508.4,
IBC 509, TABLE 601
UFC 3-600-01, 4-42.5.2.2 WAREHOUSE AND STORAGE
FACILITIES
NFPA 101, 18.4.4.5.1 FOR HAZARDOUS AREA
PROTECTION
UFC 3-600-01 4-42.5.2
3101 SEPARATION BETWEEN B AND S-1 WAREHOUSE IS
NON-RATED PER IBC TABLE 508.4 HOWEVER UFC
3-600-01 REQUIRES A ONE-HOUR FIRE RESISTIVE
RATED SEPARATION.
IBC TABLE 601, 602
3101 THE EXISTING WAREHOUSE APPEARS TO BE OF
TYPE II B CONSTRUCTION (NFPA II 000 CONSTRUCTION)
3101- COMBUSTIBLE CONSTRUCTION IS NOT ALLOWED
WITHIN S OCCUPANCIES (INTERIOR BEARING AND
NONBEARING PARTITIONS)
6. ENCLOSURE PROTECTION AND PENETRATION
REQUIREMENTS - OPENING PROTECTIVE'S
AND THROUGH PENETRATIONS
MECHANICAL ROOMS, ELECTRICAL ROOM, JANITOR
CLOSET: (1) HOUR. 1 HOUR SEPARATION BETWEEN
WAREHOUSE AND OTHER BUILDING AREAS
IBC TABLE 508.5
7. AUTOMATIC SPRINKLERS AND OTHER
EXTINGUISHING EQUIPMENT
UFC 3-600-01, CHAPTERS 4 AND 9
UFC 3-600-01, APPENDIX B
3101 BUILDING OFFICE AREA SHALL BE FULLY
SPRINKLERED WITH AN EXTENSION- MODIFICATION
OF THE EXISTING WET PIPE SPRINKLER SYSTEM AS
AN AREA OF A FULLY SPRINKLERED S-2
OCCUPANCY.
7A. UFC 3-600-01, TABLE 9.3 SPRINKLER DESIGN DENSITY:
OFFICES SPACES AND REST ROOMS LIGHT HAZARD,
0.1 GPM/SF OVER DESIGN AREA OF 1,500 SF
ORDINARY HAZARD, 0.20 GPM/SF OVER 2500 SF
WATER DEMAND FOR HOSE STREAMS:
ORDINARY HAZARD: 250 GPM
7B. NFPA 13, HIGH PILE STORAGE NO HIGH PILE STORAGE WILL BE PROVIDED IN THIS
PROJECT.
7C. UFC 3-600-01, CHAPTER 9 COVERAGE PER SPRINKLER HEAD:
LIGHT HAZARD: 225 SF PER HEAD
ORDINARY HAZARD: 130 SF PER HEAD.
7D. AVAILABLE WATER SUPPLY TESTING
UFC 3-600-01, NFPA 291
FLOW TEST CONDUCTED ON DECEMBER 14, 2017 @
13:00.
BUILDING 3101 STATIC PRESSURE: 62 PSI
RESIDUAL PRESSURE: 40 PSI WITH 1424 GPM
FLOWING,
FH COEFFICIENT: 0.90. TWO 2 ½” ORIFICES
FLOWING. FLOW AT 20 PSI 2020 GPM
7E. NFPA 13, PARA. 8.16.4.6.1 3101 BACK FLOW PREVENTERS ARE EXISTING.
8. PORTABLE FIRE EXTINGUISHERS
NFPA 10, UFC 3-600-01; SECTION 9-17
PORTABLE FIRE EXTINGUISHERS ARE NOT
REQUIRED PER UFC 3-600-01. IF REQUIRED BY
OPERATIONS EXTINGUISHERS ARE EQUIPMENT
PROVIDED BY THE GOVERNMENT.
9. FIRE AND SMOKE DAMPERS
IBC SECTION 716 AND NFPA 90A
3101 DAMPERS SHALL BE PROVIDED FOR DUCT
PENETRATIONS IN 2-HOUR FIRE RESISTIVE RATED
WALLS. NO 2 HOUR RATED WALLS ARE DESIGNED
FOR THE BUILDING SCOPE.
10. DETECTION ALARM, MASS NOTIFICATION AND
COMMUNICATION
UFC 3-600-01, CHAPTER 9
NFPA 101 PARA. 3.4 (CHAPTERS 12-42)
NFPA 72
FIRE ALARM SYSTEM IS EXISTING.
EXISTING SYSTEM WILL BE EXPANDED REPLACED
OR ALTERED AS NECESSARY TO PROVIDE
DETECTION AND NOTIFICATION IN NEW -
RECONFIGURED SPACES.
NOTIFICATION DEVICES BOTH VISUAL AND AUDIBLE
TYPE ARE REQUIRED.
11. MASS NOTIFICATION
UFC 3-600-01
NOT PROVIDED AND ALTHOUGH REQUIRED BY CODE
THE SCOPE - AREA OF THIS PROJECT DOES NOT
REQUIRE THE RETROFIT OF THE SYSTEM.
12. INTERIOR FINISHES (CLASSIFICATION)
NFPA 101, TABLE 10.2.2
NFPA 101.7.1.4
EXITS: CLASS A
EXIT ACCESS CORRIDORS: CLASS A
OTHER SPACES: CLASS A OR B
13. MEANS OF EGRESS
NFPA 101 CHAPTERS 7 AND 12- 42
ILLUMINATION OF MEANS OF EGRESS
NFPA 101.7.8 NFPA 101.7.9
ADDITIONAL BATTERY POWERED EMERGENCY
LIGHTS WILL BE PROVIDED IN THE MEANS OF
EGRESS IN THE MODIFIED SPACES.
MARKING OF MEANS OF EGRESS
NFPA 101.7.10 ADDITIONAL ILLUMINATED EXIT
SIGNAGE WILL BE PROVIDED TO INDICATE THE
PATHS OF TRAVEL TO EXITS.
13A. EGRESS CAPACITY NFPA 101.7.3.3 TABLE 7.3.3.1 STAIRS: 0.3” PER
PERSON,
LEVEL COMPONENTS AND RAMPS: 0.2” PER PERSON;
DOORS: MINIMUM 32”.
13B. NUMBER OF MEANS OF EGRESS
NFPA 101.7.4.1.2 AND CHAPTERS 12-42.
OCCUPANT LOAD OVER 100, 2 EXITS REQUIRED AND
ARE PROVIDED FROM THE NEW OFFICE SPACE.
13C. DEAD END LIMITS AND COMMON PATH OF
TRAVEL
BUILDING 3101 DEAD ENDS ARE LIMITED TO LESS
THAN THE MAXIMUM ALLOWABLE 50 FEET IN THE
OFFICE AND STORAGE AREAS.
COMMON PATHS OF TRAVEL ARE LIMITED TO LESS
THAN THE MAXIMUM ALLOWABLE 100 FEET FROM
OFFICES AND SUPPORT SPACES.
13D. MEASUREMENT OF TRAVEL DISTANCE TO
EXITS
NFPA 101.7.6 AND CHAPTERS 12-42.
BUSINESS TRAVEL DISTANCE MAXIMUM-300 FT
MAXIMUM EXPERIENCED IN NEW SPACE IS 65 FEET.
STORAGE S-1 TRAVEL DISTANCE TO EXIT: 400 FT
W/SPRINKLERS. MAXIMUM EXPERIENCED IN NEW
SPACE IS APPROXIMATELY 140 FEET.
13E. SEPARATION OF MEANS OF EGRESS BUILDING 3101 THERE ARE NO EXITING CHANGES
RESULTING FROM THE SCOPE OF WORK IN EITHER
BUILDING. NO SEPARATION OF THE MEANS OF
EGRESS IS REQUIRED AS THE BUILDING IS A SINGLE
STORY AND TRAVEL DISTANCES ARE WITHIN
MAXIMUM ALLOWABLE DISTANCES.
13F. DISCHARGE FROM EXITS NFPA 101.7.7 ALL EXISTS DISCHARGE TO A CLEAR
OPEN PUBLIC WAY.
14. OCCUPANT LOAD NFPA 101.7.3.1 AND CHAPTERS 12-42,
IBC 2016 CHAPTER 10.
3101 STORAGE (WAREHOUSE): 500 SF/PP.
AREA WITHIN SCOPE IS A BUSINESS OCCUPANCY.
OCCUPANT LOAD IS INCREASING BY A CALCULATED
45 PERSONS BUT A MANNING LOAD OF 5 PERSONS.
15. ACCESSIBILITY REQUIREMENTS
ADA AND ABA ACCESSIBILITY GUIDELINES FOR
BUILDINGS AND FACILITIES
BUILDING 3101 AN AREA OF REFUGE IS BEING
PROVIDED OUTSIDE AN ADJACENT EXIT OUTSIDE
THE SCOPE OF WORK.
DE=27
EXISTING LOADING DOCK WITH CANOPY - NO WORK THIS AREA
VEHICLE RAMP
EXISTING CONCRETE
GARAGE DOOR
EXISTING SLIDING
G A
R A
G E D
O O
R
E X
IS
T
IN
G S
L
ID
IN
D
C K D
O O
R
E X
IS
T
IN
G L
O A
D
F
IR
E D
O O
R
T O R
E M
A
IN
E X
IS
T
IN
G F
U S
IB
L E -L
K
F
IR
E D
O O
R
T O R
E M
A
IN
E X
IS
T
IN
G F
U S
IB
L E -L
K
35,633 / 500 = 72 OCCUPANTS
40,000 - 4,367 = 35,633 SF
200' X 200' = 40,000 SF
EXISTING WAREHOUSE - NO WORK THIS AREA
3,774 SF / 500 = 8 OCCUPANTS
74' X 51' = 3,774 SF
NO WORK THIS AREA
EXISTING WAREHOUSE DISTRIBUTION
ACCESSIBLE RAMP (TO REMAIN)
EXISTING ADA / ABA HANDICAP
EGRESS PATH (<100 LF)
100 = 44 OCCUPANTS
AREA AND REPLACE
DEMO EXISTING OFFICE
NO CHANGE IN OCCUPANCY
REPLACE WITH NEW RESTROOMS
DEMO EXISTING RESTROOMS AND
F E
C
F E
C
(RESCUE ASSISTANCE)
AREA OF REFUGE
92'-0" EGRESS SEPARATION (EXISTING TO REMAIN)
E X
IS
T
IN
G -H
O U
R R
A T
E D F
IR
E W
A L L S
E P
A R
A T
IO
N B
E T
W E
E N E
A C
H U
N
IT
T Y
P
IC
A L
W
IT
H R
A T
E D D
O O
R S
FIRE EXIT-1
FIRE EXIT-2
ACCESS-2
FIRE EXIT
ACCESS-1
FIRE EXIT
C P
0.2
T D
CP=42
0.2
FE
DEAD-END CORRIDOR (MEASURED IN FEET)3.
C P
T D
T D
WH
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
UNIT- A UNIT- B UNIT- C UNIT- D UNIT- E
N
GENERAL SHEET NOTES
-O
C T -2
:5
A R
C H
IT
E C
T U
R A
L
F
IR
S T F
L O
O R L
IF
E S
A F
E T
Y P
L A
N
O V
E R
A L L
A-100
FOR CONSTRUCTION
B P
E A
B O
D Y
J
O C
A S
IO
S A
N G
E R
H A
U S
E N
G
R
IG
G
IN
S
P T F
L -1
-3
-A -1
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
-1
O J E
C T -N
O
SEE FIRE ALARM PLANS FOR ANNUNCIATOR LOCATIONS AND TYPE.J.
SEE ELECT. PLANS AND SCHEDULES FOR LOCATION AND TYPE OF EXIT LIGHTS.I.
SEE SHEETS A-111 AND A-112 FOR ENLARGED PLANS AND ROOM NAMES.H.
CONSTRUCTION. COORDINATE LOCATION(S) WITH CONTRACTING OFFICER.
RELOCATE FIRE EXTINGUISHERS FROM DEMO PARTITIONS TO NEAREST NEW
EXISTING FIRE EXTINGUISHERS IN WAREHOUSE (TO REMAIN).
PROVIDE A MINIMUM OF (3) FIRE EXTINGUISHERS AT NEW RENOVATION.G.
116 X 0.2 = 24 INCH. PROVIDE 36" MINIMUM DOOR WIDTH AT EGRESS EXITS.
CONSIDER 72 + 44 = 116 OCCUPANTSF.
DEMO EXISTING OFFICE AREA AND REPLACE WITH NEW OFFICE AREA
OFFICE AREAE.
35,633 / 500 = 72 OCCUPANTS
WAREHOUSE / DISTRIBUTION AREAD.
EXISTING UNIT-E AREA = APPROXIMATELY 200' X 200' = 40,000 SF < 70,000 SF
ADD FOR SPRINKLER INCREASE (1-STORY) = 70,000 X 3 = 210,000 SF MAX.
MAXIMUM BUILDING SIZE FOR S1 OCCUPANCY (WORST CASE) = 70,000 SF
TYPE II CONSTRUCTION, SPRINKLERED, NON-SEPARATED MIXED OCCUPANCY.
UNIT - E SUMMARY:C.
REFERENCE SHEET A-010 FOR LIFE SAFETY CODE ANALYSIS.B.
DIMENSIONS PRIOR TO CONSTRUCTION.
THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND A.
0 8' 32'16'
A1
FIRST FLOOR - LIFE SAFETY PLAN
SCALE: 1/16" = 1'-0"
SQ. FEET SQ. METERSDD FORM 1391 LIMITATION
32,6043,029RENOVATIONS TO BUILDING 3101
SQ. FEETSQ. METERS AS DESIGNED
5,408502RENOVATIONS TO BUILDING 3101
LEGEND
TRAVEL DISTANCE (MEASURED IN FEET)1.
COMMON PATH (MEASURED IN FEET)2.
STORAGE (500 GROSS SQFT/PERSON)
ASSEMBLY (15 NET SQFT/PERSON)
BUSINESS (100 GROSS SQFT/PERSON)
6. EXIT CAPACITY
(INCH)EXIT CLEAR WIDTH=Z
(PERSON)EXIT CAPACITY=Y
(PERSON)OCCUPANTS USING EXIT=X
(INCH/PERSON)EXIT CAPACITY FACTOR=W
NEW 1 HOUR FIRE RESISTANCE (BARRIER)
SEE DWGS A-111 & A-112
PORTABLE FIRE EXTINGUISHER7.
FE
CODE ANALYSIS, SHEET A-100
FOR REQUIREMENTS REFER TO LIFE SAFETY
CP=XX
TD=XX
OCCUPANT LOAD4.
XX
XX
XX
FIRE RESISTANCE RATING5.
X
Y
W
Z
8. EMERGENCY EXIT LITGH
XX FACTORY / INDUSTRIAL (100 GROSS SQFT/PERSON)
FEC
DE=XX
DEAD END CORRIDOR (MEASURED IN FEET)3.
T E
L E
C O
M M
U N
IC
A T
IO
N S R
O O
M R
E L
O C
A T
IO
N
200'-5" (UNIT E)
(N
E W C
O N
S T
R U
C T
IO
N
(N
E W C
O N
S T
R U
C T
IO
N T
H
IS
A
R E
A
75'-0" (EXISTING CONSTRUCTION - NO WORK THIS AREA) 65'-1" (NEW CONSTRUCTION THIS AREA) 34'-5"
(E
X
IS
T
IN
G C
O N
S T
R U
C T
IO
N N
O W
O R
K T
H
IS
A
R E
A
WAREHOUSE - UNIT E
AD101
A1
AD102
A1
(NO WORK THIS AREA)
EXISTING WAREHOUSE
(NO WORK THIS AREA)
EXISTING WAREHOUSE
E X
IS
T
IN
G F
IR
E W
A L L B
E T
W E
E N U
N
IT
S
A-111
A1
A-112
A1
AD102
A7
A-112
A7
A
B
C
D
E
F
G
H
J
K
L
WH
T14442
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
UNIT- A UNIT- B UNIT- C UNIT- D UNIT- E
N
5352 6554 55 56 57 58 59 60 61 62 63 645150
NEW CONSTRUCTION
EXISTING CONSTRUCTION
GENERAL SHEET NOTES
LEGEND
-O
C T -2
:5
A R
C H
IT
E C
T U
R A
L
F
IR
S T F
L O
O R P
L A
N
O V
E R
A L L
A-110
FOR CONSTRUCTION
M J
O H
N S
O N
J
O C
A S
IO
S A
N G
E R
H A
U S
E N
G
R
IG
G
IN
S
P T F
L -1
-3
-A -1
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
-1
O J E
C T -N
O
A1
FIRST FLOOR PLAN - UNIT E - OVERALL
SCALE: 1/16" = 1'-0"
0 8' 32'16'
SEE SHEET AD101. FOR ADDITIONAL INFORMATION.
DEMO EXISTING OFFICE AREA AND CONSTRUCT NEW OFFICES,E.
EXISTING MECHANICAL ROOM WALLS AND CEILING TO REMAIN.D.
SEE SHEET AD102 FOR ADDITIONAL INFORMATION
DEMO EXISTING RESTROOM/OFFICE AND CONSTRUCT NEW RESTROOMS,C.
RENOVATED TO BE PROVIDED.
REPLACEMENT OF MECHANICAL SYSTEMS AND CONTROLS IN AREAS TO BE B.
OCCUPIED AND WILL BE SIGNED TO SAY SO.
THE WAREHOUSE. HORIZONTAL DECK WILL NOT BE LOAD BEARING OR
SEPARATE REST ROOM OCCUPANCIES FROM THE STORAGE OCCUPANCY OF
OCCUPANCY FROM THE STORAGE OCCUPANCY OF THE WAREHOUSE AND TO
A 1-HOUR FIRE RATED HORIZONTAL DECK IS REQUIRED TO SEPARATE OFFICE A.
AB
T E
L E
C O
M M
U N
IC
A T
IO
N S R
O O
M R
E L
O C
A T
IO
N
/1
/2
/1
/4
B
103 103A
22'-0 7/8"
41'-8"
7'-7'-8""
/1
V
IF
/1
C L
R
22'-0 7/8" 9'-4 7/8" 22'-6 1/16" 8'-11 1/8"
8'-5" 8'-10" 8'-10' 9'-0"
W
IT
H C
O L
U M
N
IG
N P
A R
T
IT
IO
A2
A2
C1
A1
5A2
C2
C1
C1 C1 C1
A2
A2 A2 A2
A2 A2
A2 A2
A2A2
A2
A2
A2
A2
A2
A2 A2 A2 C1
TO REMAIN (NIC)
EXISTING DOCK DR
A2
A1
A1
A2
A2
3 3
NO CLOSER
A
A-601A6
A-601 A4
666666
666666
9'-6"
5'-11"
WAREHOUSE
EAE OFFICE
QUALITY ASSURANCE
VEST
ELECT. RM.
514 SUPPLY
113 111 110
LOBBY
109108107
OFFICE
CORRIDOR
C O
R R
ID
O R
OPEN OFFICE
CORRIDOR
CHIEF GS-12
FLIGHT
TRAINING / FLIGHT
CC 0-3
FLIGHT
SMSGT E-8
FLIGHT
CMSGT E-9
FLIGHT
LEADERSHIP
IPE
WAREHOUSE
G
H
J
K
L
65646362616059
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
UNIT- A UNIT- B UNIT- C UNIT- D UNIT- E
N
-O
C T -2
:5
A R
C H
IT
E C
T U
R A
L
F
IR
S T F
L O
O R P
L A
N
A R
E A A
A-111
FOR CONSTRUCTION
M J
O H
N S
O N
J
O C
A S
IO
S A
N G
E R
H A
U S
E N
G
R
IG
G
IN
S
P T F
L -1
-3
-A -1
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
-1
O J E
C T -N
O
A1
FIRST FLOOR PLAN - UNIT E - AREA A
SCALE: 3/16" = 1'-0"
8'0 4' 16'
T O R
E M
A
IN
N
IC
E X
IS
T
IN
G S
L
ID
IN
G D
O
SHEET KEYNOTES
GENERAL SHEET NOTES
SEE WALL TYPES ON SHEET A-112.E.
BASE AND WALL TILE UP TO 5'-0" WITH PAINTED FINISH ABOVE.
RESTROOMS TO HAVE CERAMIC TILE FLOOR FINISH, COVED CERAMIC D.
CORRIDORS AND IPE TO HAVE VCT FLOOR FINISH.C.
FRAMING DETAILS.
REFER TO SHEET A-150 FOR NEW CEILING REQUIREMENTS AND
AND SUSPENDED ACOUSTICAL CEILINGS BELOW 1HR RATED CEILING.
CARPET; BASE; PAINTED GYPSUM WALLS, DOORS, AND DOOR FRAMES;
OFFICE AND CONFERENCE AREAS ARE TO BE FINISHED TO INCLUDE B.
SYSTEMS AND CONTROLS IN AREAS TO BE RENOVATED.
REFERENCE MECHANICAL FOR REPLACEMENT OF MECHANICAL A.
1. EXISTING EXTERIOR BUILDING WALL TO REMAIN.
2. EXISTING INTERIOR WALL TO REMAIN
3. NEW METAL STUD WITH PAINTED GYPSUM BOARD FINISHED
PARTITIONS.
4. NOT USED.
5. CASEWORK COUNTER WITH SHELF BELOW, SEE ELEVATIONS
A4 & A6 / A-601
6.
SEE DETAIL E7 / A-601 EXTERIOR AND E9 / A-601 INTERIOR.
COORD. LOCATIONS TO PROTECT CORNERS OF NEW MECH.
EQUIP.
NEW CONSTRUCTION
EXISTING CONSTRUCTION
LEGEND
A
T E
L E
C O
M M
U N
IC
A T
IO
N S R
O O
M R
E L
O C
A T
IO
N
2'-11 1/2"
/8
1'-6" 3'-0" 11'-1"
12'-0"
5'-5" 5'-8"
B1
A1
B2
B2
A2
B2
B2
B1
B1
B1
B2
B2
1'-6"
B2
B2
B2
B2
(NO WORK THIS AREA)
EXISTING WAREHOUSE
E X
IS
T
IN
G F
IR
E W
A L L B
E T
W E
E N U
N
IT
S
13'-10" (VIF)
/2 (V
IF
B2
B2
/4
HC
HC
HC
HC
HC
HC
HC
HC
WAREHOUSE - UNIT E
MEN TLT
MECH. RM.
WOMEN TLT
PUMP RM.
WH
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
UNIT- A UNIT- B UNIT- C UNIT- D UNIT- E
N
53 54 55
E
F
G
H
D
9 10
TELECOM RM.
-O
C T -2
:5
A R
C H
IT
E C
T U
R A
L
F
IR
S T F
L O
O R P
L A
N
A R
E A B
A-112
FOR CONSTRUCTION
M J
O H
N S
O N
J
O C
A S
IO
S A
N G
E R
H A
U S
E N
G
R
IG
G
IN
S
P T F
L -1
-3
-A -1
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
T
E L E
C O
M M
U N
IC
A T
IO
N S R
O O
M R
E L
O C
A T
IO
N -1
O J E
C T -N
O
A1
FIRST FLOOR PLAN - UNIT E - AREA B
SCALE: 3/16" = 1'-0"
8'0 4' 16'
SHEET KEYNOTES
GENERAL SHEET NOTES
SEE A1/A-401 FOR ADDITIONAL INFORMATION.E.
CEILINGS: MOISTURE RESISTANT 1/2" GWB·
TILE UP TO 5'-0" AFF WITH PAINTED FINISH ABOVE.
ALL OTHER WALLS: MOISTURE RESISTANT 5/8" GWB AND WALL ·
THICK FIBER REINFORCED CEMENT BOARD.
SHOWER WALLS: FULL HEIGHT TILE WALLS BACKED WITH 1/2" MIN ·
BASE: COVED CERAMIC TILE ·
FLOORS: CERAMIC TILE·
RESTROOMS FINISHES SHALL BE AS FOLLOWS:D.
CORRIDORS AND IPE TO HAVE VCT FLOOR FINISH.C.
SYSTEMS AND CONTROLS IN AREAS TO BE RENOVATED.
REFERENCE MECHANICAL FOR REPLACEMENT OF MECHANICAL B.
SAWCUTTING OF THE EXISTING CONCRETE SLAB IS REQUIRED.A.
WALL TYPE LEGEND # SHOWN THUS
A1
A2
5/8" GYPSUM BOARD (LEVEL 4 FINISH)
R-11 UN-FACED FIBERGLASS BATT INSULATION
3 5/8" (20 GAUGE) STEEL STUDS @ 16" OC
5/8" GYPSUM BOARD (LEVEL 4 FINISH)
NON-RATED INTERIOR PARTITION
PLUMBING PLANS.
NEW JANITOR'S SINK WITH MOP/BROOM SS SHELF ABV, SEE 7.
RETARDANT TREATED.
EQUIPMENT AND FURNISHINGS, ETC. ALL BLOCKING TO BE FIRE
COORDINATE BLOCKING WITH TOILET ACCESSORIES, CASEWORK, 6.
REFERENCE INTERIORS FOR FINISH SCHEDULE.
ABOVE CEILING.
ALL INTERIOR PARTITIONS SHALL EXTEND A MINIMUM OF 12 INCHES 5.
LOCATIONS (i.e. MEN'S TOILET, WOMEN'S TOILET, PUMP ROOM).
PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT ALL WET 4.
DESIGN STANDARDS.
WHERE REQUIRED TO PREVENT MOVEMENT CRACKING PER MFGR.
CONTROL JOINTS IN GYPSUM BOARD NOT TO EXCEED 30 LF AND
LIGHT GAUGE METAL FRAMING CONTRACTOR SHALL PROVIDE 3.
STRUCTURAL ENGINEER APPROVED DESIGN.
WALLS SHALL INCLUDE A STRUCTURAL TOP PLATE TRACK PER
DIRECTLY OVER STUD FRAMING BELOW. ALTERNATE: BEARING
1-HOUR RATED CEILING CONSTRUCTION JOISTS SHALL BEAR 2.
WORKMANSHIP.
NECESSARY TO COMPLY WITH MFGR. DESIGN STANDARDS AND
MEMBER SIZE, TYPE AND GAUGE WITH STRUCTURAL ENGINEER AS
LIGHT GAUGE METAL FRAMING CONTRACTOR SHALL COORDINATE 1.
5/8" GYPSUM BOARD (LEVEL 4 FINISH)
R-11 UN-FACED FIBERGLASS BATT INSULATION
3 5/8" (20 GAUGE) STEEL STUDS @ 16" OC
NON-RATED INTERIOR PARTITION
B1
B2
5/8" GYPSUM BOARD (LEVEL 4 FINISH)
R-11 UN-FACED FIBERGLASS BATT INSULATION
6" (20 GAUGE) STEEL STUDS @ 16" OC
5/8" GYPSUM BOARD (LEVEL 4 FINISH)
NON-RATED INTERIOR PARTITION
5/8" GYPSUM BOARD (LEVEL 4 FINISH)
R-11 UN-FACED FIBERGLASS BATT INSULATION
6" (20 GAUGE) STEEL STUDS @ 16" OC
NON-RATED INTERIOR PARTITION
1. INTERIOR WALL SEPARATOR- FIRE RATED OPENINGS.
2.EXISTING INTERIOR CONSTRUCTION TO REMAIN
3.NEW METAL STUD WITH PAINTED GYPSUM BOARD FINISHED
PARTITIONS.
4.UTILITY SINK, SHELF, AND MOP HANGERS.
5.EXISTING SEWER SUMP PUMP (SEE PLUMBING).
6.
SEE DETAIL E7 / A-601 EXTERIOR AND E9 / A-601 INTERIOR.
COORD. LOCATIONS TO PROTECT CORNERS OF NEW MECH. EQUIP.
7. 3'-0" X 7'-0" HM FRAME AND DOOR WITH STORAGE LOCKSET.
8.PATCH WALLS AND PAINT TO MATCH
9.FLOOR TO MATCH TO EXISTING.
10.BASE TO MATCH EXISTING.
C1
6" FIBERGLASS BATT INSULATION
SIDE 2: 5/8" FIRE SHIELD GYPSUM BOARD
SIDE 1: 5/8" FIRE SHIELD GYPSUM BOARD
6" WIDE (20 GAUGE) STEEL STUDS @ 16" O.C.
BOTTOM:
FROM FLOOR TO UNDERSIDE OF STRUCTURE, SEAL TOP AND
AND INSULATED WALL, ALL PARTITION COMPONENTS EXTEND
1 HR RATED (NGC 2013022, UL DESIGN NO. U465) NON-BEARING
C2
6" FIBERGLASS BATT INSULATION
SIDE 2: 5/8" GYPSUM BOARD (LEVEL 4 FINISH)
SIDE 1: NONE
6" WIDE , 20 GA @ 16" O.C.
NON-RATED NON-BEARING AND INSULATED WALL
(ROOM SIDE)
B
FRAMING GENERAL NOTES
A7
ENLARGED PARTIAL FLOOR PLAN AT NEW TELECOM RM
SCALE: 3/16" = 1'-0"
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
UNIT- A UNIT- B UNIT- C UNIT- D UNIT- E
N
VEST
WAREHOUSE
ELECT. RM.
MECH. RM.
A-150
F3
TYP
EXH
E X
IS
T
IN
G
1HR FIRE RATED CEILING ABOVE ACOUSTICAL CEILING - SEE NOTES
(NEW WALL CONSTRUCTION AND CEILINGS THIS AREA)
H
R F
IR
E R
A T
E D C
E
IL
IN
G A
B O
V E A
C O
U S
T
IC
A L C
E
IL
IN
G S
E E N
O T
E S
N
E W W
A L L C
O N
S T
R U
C T
IO
N A
N D C
E
IL
IN
G S T
H
IS
A
R E
A
EXISTING MECH. ROOM WALLS AND CEILING TO REMAIN
EXISTING CEILING TO REMAIN - NO WORK IN THIS AREA
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"9'-0"9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
DEMO EXISTING ACT AT NEW TELECOM RM
TELECOM RM.
EXH
EXH
N E
W W
A L L S A
N D C
E
IL
IN
G S
9'-0"
9'-0"
1. FINISH FLOORING -- MIN 19/32 IN. THICK WOOD STRUCTURAL PANELS, MIN GRADE
"UNDERLAYMENT" OR "SINGLE-FLOOR". FACE GRAIN OF PLYWOOD OR STRENGTH AXIS OF
PANEL TO BE PERPENDICULAR TO JOISTS WITH JOINTS STAGGERED. LONG EDGES SHALL
BE T & G.
2. FLOORING FASTENERS — (NOT SHOWN) - THE SUBFLOORING (FIRST LAYER) OF EACH
FLOOR SYSTEM AND FINISH FLOORING OF SYSTEM NO. 1 ARE TO BE FASTENED TO THE
STEEL JOISTS WITH TYPE S12 BY 1-15/16 IN. LONG SELF-DRILLING, PILOT POINT, STEEL
SCREWS. THE SCREWS ARE TO BE SPACED 6 IN. OC AROUND THE PERIMETER OF THE
FLOOR AND AT ALL END (BUTT) JOINTS OF THE PANELS. SPACING IN THE FIELD TO BE 10 IN.
OC. FOR FLOORING SYSTEM NO. 2, THE FINISH FLOORING IS TO BE FASTENED TO THE
SUBFLOORING WITH TYPE S12 BY 2 IN. LONG STEEL SCREWS SPACED 6 IN. OC AROUND
THE PERIMETER OF THE FLOOR AND AT ALL END (BUTT) JOINTS OF THE FINISH FLOORING
PANELS. SPACING IN THE FIELD TO BE 10 IN. OC WITH ROWS OF SCREWS SPACED 16 IN. OC.
3. STRUCTURAL STEEL MEMBER — MIN W8 X 15 WIDE FLANGE STEEL BEAM.
4. STEEL JOISTS — THE JOISTS ARE CHANNEL-SHAPED, MIN 7 IN. DEEP WITH MIN 1-5/8 IN.
WIDE FLANGES AND 1/2 IN. LONG STIFFENING FLANGES. THE JOISTS ARE FABRICATED
FROM MIN NO. 18 MSG GALV STEEL. MIN YIELD STRENGTH OF STEEL IS EITHER 33,000 OR
40,000 PSI WITH CORRESPONDING MAX WORKING STRESS OF 20,000 AND 24,000 PSI. JOISTS
SPACED MAX 24 IN. OC. AT JOIST SPLICES BEARING ON SUPPORTS, JOISTS ARE
OVERLAPPED A MIN OF 3 IN. WHEN CEILING DAMPER (ITEM 8) IS USED, MIN JOIST DEPTH IS
14 IN.
5. JOIST STIFFENERS — (NOT SHOWN) - CHANNEL-SHAPED STIFFENERS, MADE FROM MIN
NO. 18 MSG GALV STEEL. STIFFENERS ARE 6-13/16 IN. LONG, 3-1/2 IN. DEEP WITH 1-5/8 IN.
FLANGES AND 1/2 IN. STIFFENING FLANGES. THE JOIST STIFFENERS ARE USED AT ALL
BEARING LOCATIONS OF THE JOISTS.
6. JOIST BRIDGING — (NOT SHOWN) - INSTALLED IMMEDIATELY AFTER JOISTS ARE
ERECTED AND BEFORE CONSTRUCTION LOADS ARE APPLIED. THE BRIDGING CONSISTING
OF JOIST SECTION CUT TO LENGTH AND PLACED BETWEEN OUTER SUPPORTS, ADJACENT
TO OPENINGS AND AT MID-SPAN WITH 8 FT OC MAX SPACING. BRIDGING CHANNELS ARE
SCREW-ATTACHED AT EACH END TO JOIST WEBS USING ANGLE CLIPS. V-BRACING OF 1-1/2
IN. BY 20-GAL GALVANIZED STEEL IS SCREW-ATTACHED TO BOTTOM JOIST FLANGE
BETWEEN BRIDGING CHANNELS.
6A. HORIZONTAL JOIST BRIDGING — USED IN LIEU OF ITEM 6 IN SAME JOIST BAY AS
CEILING DAMPER (ITEM 8), WHEN CEILING DAMPER IS EMPLOYED. JOIST SECTION CUT TO
LENGTH AND SECURED TO JOISTS ABOVE BOTTOM FLANGES WITH TYPE S12 SCREWS AND
1-1/2 BY 1-1/2 IN. NO. 18 MSG GALV STEEL ANGLES.
7. BEAM CAGE — THE CAGE USED TO SUPPORT THE GYPSUM BOARD BEAM PROTECTION IS
FABRICATED FROM NO. 24 MSG ELECTROGALVANIZED STEEL ANGLE WITH 7/8 BY 1-3/8 IN.
LEGS AND NO. 25 MSG, ELECTROGALVANIZED STEEL CHANNEL STUDS, 2-1/2 IN. WIDE WITH 1
IN. LEGS. ANGLES ARE FASTENED TO THE STEEL JOISTS USING 1/2 IN. PAN HEAD STEEL
SHEET METAL SCREWS.
8. CEILING DAMPER* — (OPTIONAL) - MAX NOM AREA SHALL BE 198 SQ IN. MAX
RECTANGULAR SIZE SHALL BE 12 IN. WIDE BY 16-1/2 IN. LONG. MAX HEIGHT OF DAMPER
SHALL BE 8-3/4 IN. AGGREGATE DAMPER OPENINGS SHALL NOT EXCEED 99 SQ IN. PER 100
SQ FT OF CEILING AREA. DAMPER INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS
INSTALLATION INSTRUCTIONS PROVIDED WITH THE DAMPER. A STEEL GRILLE (ITEM 13)
SHALL BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS.
RUSKIN COMPANY — MODEL CFD7
9. CEILING DAMPER SUPPORT — (NOT SHOWN) - PROVIDED WITH CEILING DAMPER.
SUPPORT SECURED TO CEILING DAMPER AND STEEL JOISTS IN ACCORDANCE WITH
INSTALLATION INSTRUCTIONS PROVIDED WITH CEILING DAMPER.
10. GYPSUM BOARD* — FOR CEILING - TWO LAYERS OF 1/2 IN. THICK GYPSUM BOARD
INSTALLED WITH LONG DIMENSIONS PERPENDICULAR TO JOISTS. BASE LAYER ATTACHED
TO STEEL JOISTS USING 1 IN. LONG, TYPE S12 BUGLE HEAD STEEL SCREWS SPACED 8 IN.
OC ALONG BUTT JOINTS AND 12 IN. OC IN FIELD ALONG THE JOISTS. BUTT JOINTS TO
OCCUR BENEATH JOISTS WITH SCREWS LOCATED 1/2 IN. FOR THE BUTT JOINTS. OUTER
LAYER ATTACHED TO ASSEMBLY USING 1-1/2 IN. LONG, TYPE G BUGLE HEAD STEEL
SCREWS SPACED 8 IN. OC ALONG BUTT JOINTS AND WITH 1-5/8 IN. LONG, TYPE S12 BUGLE
HEAD STEEL SCREWS SPACED 12 IN. OC IN THE FIELD ALONG THE JOISTS. BUTT JOINTS OF
OUTER LAYER TO OCCUR BETWEEN JOISTS WITH SCREWS LOCATED 3/4 IN. FROM THE
BUTT JOINTS. EDGE JOINTS TO BE STAGGERED BETWEEN LAYERS. FOR BEAM - TWO
LAYERS OF 1/2 IN. THICK GYPSUM BOARD FASTENED TO BEAM CAGE. INNER LAYER
SECURED USING 1 IN. LONG, TYPE S12 BUGLE HEAD STEEL SCREWS SPACED 12 IN. OC AND
OUTER LAYER FASTENED TO CAGE USING 1-5/8 IN. LONG, TYPE S12 BUGLE HEAD STEEL
SCREWS SPACED 12 IN. OC. JOINTS ARE TO BE STAGGERED BETWEEN LAYERS.
9'-0"
B.O. 2' X 2' ACOUSTICAL CLG
12'-0"
B.O. 1HR RATED CLG
1HR RATED WALL
1-HOUR RATED PARTITION WALL
-O
C T -2
:5
A R
C H
IT
E C
T U
R A
L
F
IR
S T F
L O
O R C
E
IL
IN
G P
L A
N
O V
E R
A L L
A-150
FOR CONSTRUCTION
M J
O H
N S
O N
J
O C
A S
IO
S A
N G
E R
H A
U S
E N
G
R
IG
G
IN
S
P T F
L -1
-3
-A -1
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O O
W N
E R C
O M
M E
N T S
-0
-1
-1
O J E
C T -N
O
A1
REFLECTED CEILING PLAN - UNIT E
SCALE: 1/8" = 1'-0"
GENERAL SHEET NOTES
2X4 LAY-IN LIGHT FIXTURE
2X2 LAY-IN CEILING GRID
RETURN AIR DIFFUSER
SUPPLY AIR DIFFUSER
RESTROOM EXHAUST FAN
1/2" GYPSUM BOARD CEILING w/ SMOOTH PAINTED FINISH
SHOWER LIGHT/ EXHAUST FAN
SPRINKLER HEADS
REFLECTED CEILING LEGEND
AB
0 8'4' 16'
A. SEE SHEET A-601 FOR DOOR SCHEDULE.
B. REPLACEMENT OF MECHANICAL SYSTEMS AND CONTROLS IN
AREAS TO BE RENOVATED TO BE PROVIDED.
C. PROVIDE ACCESS AND ALL CONNECTIONS FOR OWNER
PROVIDED EQUIPMENT.
D. 1HR RATED CEILING ABOVE ACOUSTICAL CEILING: UL DESIGN NO.
L524 TOP OF RATED CEILING @ 12'-0" AFF. PROVIDE AND SUBMIT
A COMPLETE SET OF SHOP DRAWINGS WITH LIGHT GAUGE
FRAMING AND ASSOCIATED STRUCTURAL MEMBERS OF
DELEGATED DESIGN SIGNED AND SEALED BY A PROFESSIONAL
LICENSED ENGINEER IN THE STATE OF NEW JERSEY.
E. REFERENCE: INTERIORS FOR CEILING HEIGHT AND FINISHES.
F. REFERENCE: ELECTRICAL FOR FIXTURE TYPE AND LOCATION.
G. REFERENCE: MECH. FOR DIFFUSER TYPE AND LOCATION.
REFERENCE: MECH. FOR FIRE DAMPERS AND PENETRATION FIRE
CAULKING DETAILS.
H. REFERENCE: FIRE PROTECTION FOR SPRINKLER HEAD AND
ALARM AND LOCATIONS.
I. PROVIDE SIGNAGE PAINTED ON EXPOSED VISIBLE SURFACE OF
OF PLYWOOD DECK AT 1-HOUR RATED CEILING ASSEMBLY
STATING 'NO STORAGE ALLOWED'. THIS PLATFORM IS NOT
INTENDED FOR STORAGE WEIGHT. PROVIDE SIGN CONSISTING
OF 2" YELLOW LETTERING PLACED AT 20 FEET AROUND THE
PERIMETER.
CEILING HEIGHT, ELEVATION ABOVE FINISHED FLOOR
1HR RATED CEILING UL DESIGN NO. L524, SYSTEM 1
F3
SECTION @ RATED CEILING
SCALE: NTS
EXH
1X4 LAY-IN LIGHT FIXTURE
T E
L E
C O
M M
U N
IC
A T
IO
N S R
O O
M R
E L
O C
A T
IO
N
5"
2" 5"
2"
2" AS SCHED. 2"
3"
2" AS SCHED. 2"
2'-0"
2" 2"
2" 2"
AS SCHED. 2"
2" 2"
2" 2"
2" AS SCHED.2"
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.