Amendment_0007_Alter_Faciltities_for_MX_-_Plans.pdf
PDF 8 MB Posted
- Attached to
- KC-46A Alter Facilities for Maintenance Federal contract opportunity
- Solicitation number
- W912DS18B0023
About this file
Plans
View the file
Other files for this federal contract opportunity
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S E
Y
W
E
R -1
-D -0
N O
V E
M B
E R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
-N
O V -2
:4
S T
R U
C T
U R
A L
G E
N E
R A
L N
O T
S
S-001
FOR CONSTRUCTION
K L E
S T
E R
J P
IT
T M
A N
L P
R E
S L E
Y
G
R
IG
G
IN
S
P T F
L -1
-0
-S -0
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1 f 'c = 4,500 PSI
1924#3
SIZE
BAR
ALL LENGTHS ARE IN INCHES
BARS
TOP
BARS
OTHER
LAP SPLICE
CLASS "B"
2532#4
3140#5
3748#6
5470#7
6280#8
70#9
79#10
#11
(GRADE 60 UNCOATED BARS)
BY A FACTOR OF 1.5. (db = REINFORCING BAR DIAMETER)
OR 3 db FOR ALL OTHER CONCRETE ELEMENTS, LENGTHS SHALL BE MULTIPLIED
3. WHEN REINFORCING BAR SPACING IS LESS THAN 2 db FOR BEAMS AND COLUMNS
2. REINFORCING BAR LENGTHS ARE BASED ON NORMAL-WEIGHT CONCRETE.
CAST BELOW.
1. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12 INCHES OF CONCRETE
NOTES:
DESIGN CRITERIA: CONCRETE:
7.
8.
10.
CONCRETE PROPERTIES:
4,500 PSI
1.
2.
TYPICAL CONCRETE (UNLESS NOTED OTHERWISE)
MINIMUM 28 DAY
COMPRESSIVE STRENGTH
3.
4.
5.
1.
2.
3.
4.
5.
WIND LOAD:
C
1.0
ULTIMATE WIND SPEED (3-SECOND GUST) 115 MPH
IMPORTANCE FACTOR, I
EXPOSURE
INTERNAL PRESSURE COEFFICIENT, GCpi
6.
8. TYPICAL REINFORCING STEEL:
DEFORMED BARS (NON-WELDABLE) ASTM A615, GRADE 60
9.
DESCRIPTION COVER
3"
2"
#14 AND LARGER
#11 AND SMALLER
"2
10.
11.
"2
"4
UNIFIED FACILITIES CRITERIA (UFC) STANDARDS:
COLLATERAL LOAD:
ROOF - (LIGHTS, MEP, ETC.)
PARTITIONS
LIVE LOAD:
ROOF:
10 PSF
15 PSF
20 PSF (NON-REDUCIBLE)
300 PSF
FIRST FLOOR (SLAB-ON-GRADE):
FLOOR:
ROOF LIVE LOAD
7.
6.
BAR CONGESTION, FIELD CONDITIONS, ETC.
INCREASE CONCRETE COVER AS REQUIRED TO ACCOMMODATE EMBEDDED ITEMS,
SCHEDULE, UNLESS NOTED OTHERWISE IN A SPECIFIC SECTION OR DETAIL.
PROVIDE THE MINIMUM CONCRETE COVER INDICATED IN THE FOLLOWING
AND JOISTS
SLABS, WALLS,
PRIMARY REINFORCEMENT, SPIRALS)
BEAMS AND COLUMNS (TIES, STIRRUPS
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH
CONTACT WITH GROUND:
TO WEATHER OR IN
CONCRETE NOT EXPOSED
FOLLOWING, UNLESS OTHERWISE SPECIFIED:
ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF THE DESIGN CODE AND STANDARD:
ENCLOSURE CLASSIFICATION ENCLOSED
+/- 0.18
RISK CATEGORY II
1.0
SEISMIC LOAD:
SPECTRAL RESPONSE ACCELERATIONS:
S
S
0.213
0.096D1S
SDS
S
D
BSEISMIC DESIGN CATEGORY
ANALYSIS PROCEDURE EQUIVALENT LATERAL
FORCE PROCEDURE
IMPORTANCE FACTOR, Ie
SITE CLASS
7.
9.
UNLESS NOTED OTHERWISE.
DIMENSIONS SHOWN ARE TO THE CENTERLINE OF MEMBERS OR FACE OF WALLS,
CENTERED ON GRID LINES, UNLESS NOTED OTHERWISE.
ALL COLUMNS, FOOTINGS, PIERS, OR OTHER FOUNDATION ELEMENTS SHALL BE
BETWEEN DIMENSIONS SHOWN.
UNLESS NOTED OTHERWISE, BEAMS AND JOISTS SHALL BE EQUALLY SPACED
APPLICATION:
CONCRETE EXPOSED TO EARTH OR WEATHER
ELEVATION AND BUILDING COORDINATE LOCATIONS.
OF 100'-0". REFER TO THE CIVIL SITE PLAN FOR ACTUAL FINISH FLOOR DATUM
ALL ELEVATIONS ARE REFERENCED TO RELATIVE FINISH FLOOR DATUM ELEVATION
FULL AMPLITUDE OF APPROXIMATELY 1/4 INCH.
PLACING ADJACENT CONCRETE. CONCRETE SURFACES SHALL BE ROUGHENED A
ROUGHEN AND CLEAN CONSTRUCTION JOINTS IN WALLS AND SLABS PRIOR TO
CHAMFERED 3/4 INCH, UNLESS SPECIFICALLY NOTED OTHERWISE.
EXPOSED EDGES OF CONCRETE (BEAMS, COLUMNS, WALLS, ETC.) SHALL BE
BY THE SAME AMOUNT.
MINIMUM CONCRETE COVER FOR REINFORCING SHALL BE INCREASED ACCORDINGLY
SHALL BE WIDENED AT LEAST 3 INCHES MORE THAN THE REQUIRED DIMENSION. THE
WHEN THE SIDES OF GRADE BEAMS OR PIER CAPS ARE EARTH-FORMED, EACH SIDE
EMBEDDED ALUMINUM CONDUITS AND PIPES SHALL NOT BE PERMITTED.
WALLS, BEAMS, OR COLUMNS UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS.
CONDUITS, PIPES, DUCTS, OR SLEEVES SHALL NOT BE EMBEDDED WITHIN SLABS,
TO PLACEMENT OF CONCRETE.
ELECTRICAL, AND ARCHITECTURAL DRAWINGS, AND EQUIPMENT FURNISHED PRIOR
INSERTS, DOWELS, DEPRESSIONS, CURBS, PITS, CONDUITS, ETC. WITH MECHANICAL,
COORDINATE SIZE AND LOCATION OF EMBEDDED ITEMS, OPENINGS, SLEEVES,
WALLS. PROVIDE CONTACT LAP SPLICES.
LAP WITH HORIZONTAL BARS AT CORNERS AND INTERSECTIONS OF FOOTINGS AND
TABLES, UNLESS NOTED OTHERWISE. PROVIDE BENT CORNER BARS TO MATCH AND
REINFORCING BAR LAP SPLICES SHALL BE IN ACCORDANCE WITH THE FOLLOWING
318, UNLESS SPECIFICALLY NOTED OTHERWISE.
STANDARD HOOKS CONFORMING TO THE BEND DIMENSION REQUIREMENTS OF ACI
ALL REINFORCING BAR HOOKS INDICATED ON THE DRAWINGS SHALL BE ACI
ASCE 7-10: MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
2015 INTERNATIONAL BUILDING CODE
CHANGE I, 1 OCTOBER 2013
UFC 4-010-01; DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, UFC 3-310-04; SEISMIC DESIGN FOR BUILDINGS, CHANGE 1, 20 JUNE 2016
UFC 3-301-01; STRUCTURAL ENGINEERING, CHANGE 3, 12 SEPTEMBER 2016
UFC 1-200-01; GENERAL BUILDING REQUIREMENTS, 20 JUNE 2016
GENERAL CONSTRUCTION:
2.
3.
4.
5.
6.
1.
WITH EQUIPMENT FURNISHED PRIOR TO PROCEEDING WITH RELATED WORK.
AND ROOFS WITH MECHANICAL, ELECTRICAL, AND ARCHITECTURAL DRAWINGS, AND
VERIFY SIZE AND LOCATION OF ALL OPENINGS THROUGH FLOORS, WALLS, SLABS,
SPECIFICALLY DETAILED OR APPROVED IN WRITING BY THE C.O.
STRUCTURAL MEMBERS SHALL NOT BE CUT (FOR PIPES, DUCTS, ETC.) UNLESS
THE WORK.
RIGGING, GUYS, SCAFFOLDING, FORMWORK, ETC. REQUIRED TO SAFELY PERFORM
ALL WORK RELATED TO CONSTRUCTION, ERECTION METHODS, BRACING, SHORING,
EXCEED THE DESIGN LIVE LOADS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
INDICATE THE METHOD OF CONSTRUCTION. CONSTRUCTION LOADS SHALL NOT
THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO NOT
BURIED ITEMS PRIOR TO CONSTRUCTING FOUNDATIONS.
COORDINATE WITH THE C.O. TO LOCATE ALL EXISTING UNDERGROUND UTILITIES AND
MEMBER SIZES ON THE REFERENCE DRAWINGS MUST BE VERIFIED.
REFERENCE. AS NOTED PREVIOUSLY, ALL EXISING ELEVATIONS, DIMENSIONS AND
FOLLOWING ARE EXISTING STRUCTURAL DRAWINGS THAT MAY BE USED FOR
IMMEDIATE ATTENTION OF THE C.O. PRIOR TO PROCEEDING WITH RELATED WORK.
THE CONTRACT DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE
CONSTRUCTION. ALL OMISSIONS OR CONFLICTS BETWEEN VARIOUS ELEMENTS OF
AND MEMBERS SIZES OF EXISTING CONSTRUCTION WHICH AFFECT NEW
PRIOR TO FABRICATION AND CONSTRUCTION, VERIFY ALL ELEVATIONS, DIMENSIONS
USED TO DETERMINE SPECIFIC DIMENSIONS OR QUANTITY OF MATERIALS.
ON THE DRAWINGS ARE INTENDED FOR INFORMATION USE ONLY AND SHALL NOT BE
STRUCTURAL DRAWINGS SHALL NOT BE SCALED. REFERENCE SCALES INDICATED
ACI 301; SPECIFICATIONS FOR STRUCTURAL CONCRETE
ACI 318; BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
1.
2.
3.
4.
5.
6.
7.
MASONRY:
2,000 PSISPECIFIED DESIGN STRENGTH OF MASONRY, f 'm
CONCRETE MASONRY PROPERTIES:
a) b) c) a) b)
GROUTING:
SPECIFICALLY NOTED OTHERWISE.
MASONRY COURSES SHALL BE PLACED IN A RUNNING BOND PATTERN, UNLESS
REQUIREMENTS ARE NOT MET.
STRENGTH METHOD. PRISM TEST METHOD IS REQUIRED WHEN THE ABOVE
COMPRESSIVE STRENGTH OF MASONRY SHALL BE DETERMINED BY THE UNIT
CELLS.
EMBEDDED CONDUITS, PIPES, AND SLEEVES SHALL NOT BE LOCATED IN GROUTED
8.
a) b)
SEE CMU WALL REINFORCING SCHEDULE
c)
9.
a) b)
VERTICAL REINFORCING (UNLESS NOTED OTHERWISE ON THE DRAWINGS):
HORIZONTAL REINFORCING (UNLESS NOTED OTHERWISE ON THE DRAWINGS):
c) d)
PROVIDE MATCHING DOWELS FOR ALL VERTICAL REINFORCING.
- EACH SIDE OF CONTROL JOINTS
- BEAM BEARING
- JAMBS
- OPENINGS
- WALL ENDS
- INTERSECTIONS
- CORNERS
OF WALL AT ALL:
PROVIDE ADDITIONAL VERTICAL BARS (CENTERED) ALONG FULL HEIGHT
HOT-DIPPED GALVANIZED WITH CORROSION RESISTANT COATING.
W1.7 (9 GAGE) CROSS WIRES. JOINT REINFORCING SHALL BE
REINFORCING SHALL CONSIST OF W2.8 (3/16 INCH) SIDE WIRES AND
PROVIDE WIRE LADDER TYPE JOINT REINFORCING AT 16 INCHES.
10.
REINFORCING, AT CORNERS AND WALL INTERSECTIONS.
PROVIDE BENT BARS, TO MATCH HORIZONTAL BOND BEAM
CONTINUOUS THROUGH CONTROL JOINTS.
OF FREE-STANDING WALLS AND WHERE NOTED. BARS SHALL BE
DEPTH) AT ROOF AND ELEVATED FLOOR LINES, TOP OF PARAPETS, TOP
PROVIDE (2) #5 CONTINUOUS BARS IN BOND BEAMS (8 INCH MINIMUM
BE CONTINUOUS THROUGH CONTROL JOINTS.
LAP SPLICE JOINT REINFORCING 8 INCHES. JOINT REINFORCING SHALL
UNLESS OTHERWISE SPECIFIED:
ALL MASONRY WORK SHALL CONFORM TO THE REQUIREMENTS OF THE FOLLOWING,
ABSORBED.
PLACING AND RECONSOLIDATED AFTER EXCESS MOISTURE HAS BEEN
GROUT SHALL BE CONSOLIDATED BY MECHANICAL VIBRATION DURING
ON THE DRAWINGS.
SOLID GROUT ADDITIONAL MASONRY AREAS SPECIFICALLY INDICATED
SOLID GROUT ALL PIERS, COLUMNS, HEADERS, AND BOND BEAMS.
WALLS SUCH THAT NO STRAIGHT RUN OF WALL EXCEEDS 48 FEET.
UNLESS NOTED OTHERWISE ON THE PLANS, PLACE CONTROL JOINTS IN MASONRY
STAGGERED BY 24 INCHES WHEN SEPARATED BY 3 INCHES OR LESS.
LAP SPLICES SHALL BE 72 BAR DIAMETERS. ADJACENT LAP SPLICES SHALL BE
11.
COMPRESSIVE STRENGTH OF 2000 TO 4000 PSI.
GROUT: ASTM C476 GROUT. GROUT SHALL HAVE A 28-DAY
MORTAR: ASTM C270, TYPE S. MASONRY CEMENT SHALL NOT BE USED.
COMPRESSIVE MASONRY STRENGTH.
CONCRETE MASONRY UNITS: ASTM C90, MEDIUM WEIGHT, NET 2800 PSI
ACI 530; BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES
ACI 530; SPECIFICATION FOR MASONRY STRUCTURES
20 PSFROOF/CEILING LIVE LOAD (UNO)
INTERIOR ROOF/CEILING:
STRUCTURAL DRAWINGS
AS-BUILT SUBMISSION 3/13/06
C-17 HANGER/AIRCRAFT MAINTENANCE FACILITY
MCGUIRE AIR FORCE BASE, NEW JERSEY
150 PSF
(LIGHT STORAGE OR HVAC)
BUILDING 2201 VAULT ROOF
(MATCH EXISTING LL)
BUILDING 2201 VAULT
300 PSF
(MATCH EXISTING LL)
ROOMS NORTH OF VAULT
NO WIND LOAD
BUILDING 2201 VAULT AREA
INTERIOR STRUCTURE
29.7 PSF
BUILDING 1817 NEW SOUTH WALL FRAMING
BASE PRESSURE q
W/10.6 DEGREE ROOF SLOPE)
(BLDG 154'x69'x38' MEAN ROOF HT
+35.0/-38.0 PSF
WALL COMPONENT PRESSURES (WALL ZONE 4)
10 SF
+31.4/-34.3 PSF50 SF
+29.8/-32.8 PSF100 SF
+27.3/-30.3 PSF300 SF
+26.1/-29.1 PSF500 SF
h
BUILDING 1817 NEW SOUTH WALL FRAMING
SEISMIC LOAD ENVELOPED BY WIND LOAD
BUILDING 2201 VAULT
BEARING WALL SYSTEM
ORDINARY REINFORCED CONCRETE SHEAR WALLS
4RESPONSE MODIFICATION FACTOR, R
0.053SEISMIC RESPONSE COEFFICIENT, Cs
36 KIPSBASE SHEAR, V
FOUNDATIONS:
NOTE 2 OF "GENERAL CONSTRUCTION" NOTES THIS DRAWING.
NOTES ON SHEET S-001 AND SHEET SB-102 OF REFERENCED DRAWINGS NOTED IN
FOR ORIGINAL SOIL BEARING AND COMPACTION REQUIREMENTS, SEE FOUNDATION
REINFORCEMENT METHODS.
SETTLEMENT ARE ACHIEVED USING APPROPRIATE SOIL PREPARATION AND/OR
GEOTECHNICAL SERVICES TO ENSURE ALLOWABLE BEARING PRESSURE AND
BEARING PRESSURE OF 1500 PSF WITH NEGLIGIBLE SETTLEMENT (< 1/4"). PROVIDE
BUILDING 2201 VAULT MAT FOUNDATION DESIGN IS BASED ON AN ALLOWABLE SOIL
AND REINFORCING STEEL.
DOCUMENTS. THE OBSERVATION SHALL BE MADE PRIOR TO PLACEMENT OF FORMS
ENGINEER, OR DESIGNEE, TO VERIFY CONFORMANCE WITH THE CONTRACT
ALL FOUNDATION BEARING SURFACES SHALL BE OBSERVED BY A GEOTECHNICAL
2.
1.
12.
SYSTEM SPECIFIED IN "POST-INSTALLED ANCHORS", S-002.
INSTALL EPOXY REBAR DOWELS IN CONCRETE USING ADHESIVE ANCHORING
3.
09065010 Snapshot
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
N O
V E
M B
E R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
-N
O V -2
:4
S T
R U
C T
U R
A L
G E
N E
R A
L N
O T
S-002
L E
S T
E R
J P
IT
T M
A N
L P
R E
S L E
Y
G
R
IG
G
IN
S
P T F
L -1
-0
-S -0
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
STEEL FORM DECK AND COMPOSITE DECK:
1.
1.013
1.013
1.58
GALVANIZED G90
2.
4.
12" MAXIMUM
5.
6.
7.
8.
3"
36/4 PATTERN
AT 36" MAXIMUM
#10 SCREWS OR CRIMP/BUTTON PUNCHES SIDELAPS
SUPPORTS PARALLEL TO DECK
SUPPORTS
DECK ATTACHMENT:
40 KSI
SHALL NOT BE USED WITH FORM DECK.
CONCRETE WITH CALCIUM CHLORIDE OR ANY ADMIXTURE CONTAINING CHLORIDES
MINIMUM DECK BEARING SHALL BE 2 INCHES ON SUPPORTS.
SHEETS SHALL HAVE LAPPED ENDS. MINIMUM LAP SHALL BE 2 INCHES.
MANUFACTURER'S AND SDI MAXIMUM SPAN REQUIREMENTS.
LESS THAN TWO SPANS, SHORE THE DECK IN ACCORDANCE WITH THE
DECK SHALL BE CONTINUOUS OVER TWO OR MORE SPANS. FOR CONDITIONS WITH
FINISH
Sn (in3 / ft)
Sp (in3 / ft)
I (in4 / ft)
MINIMUM YIELD STRENGTH
GAGE
DEPTH
MINIMUM FORM DECK PROPERTIES:
AWS D1.3-98; STRUCTURAL WELDING CODE - SHEET STEEL
ANSI/SDI NC1.0-2006; STANDARD FOR NON-COMPOSITE STEEL FLOOR DECK
SDI; DIAPHRAGM DESIGN MANUAL THIRD EDITION, SEPTEMBER 2004
DECKS, NOVEMBER 2007
SDI; DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS, AND ROOF
ACCORDANCE WITH THE FOLLOWING, UNLESS OTHERWISE SPECIFIED:
ALL STEEL FORM DECK SHALL BE DETAILED, FABRICATED, AND ERECTED IN 1.
2.
POST-INSTALLED ANCHORS:
3.
ANCHOR ELEMENTS SHALL CONFORM WITH THE RESPECTIVE ICC-ES REPORT.
4. MECHANICAL ANCHORING SYSTEMS IN CONCRETE SHALL BE AS FOLLOWS:
5.
INCHES (MINIMUM) ABOVE AND BELOW ANCHOR LOCATION.
NOT ENCOUNTERED, CELL FACE SHALL BE BROKEN AND GROUTED SOLID 8
ANCHORS SHALL BE INSTALLED IN GROUTED CELLS. IF GROUTED CELLS ARE
ANCHOR ELEMENTS SHALL CONFORM WITH THE RESPECTIVE ICC-ES REPORT.
ADHESIVE ANCHORING SYSTEMS IN MASONRY SHALL BE AS FOLLOWS:
6.
MECHANICAL ANCHORING SYSTEMS IN MASONRY SHALL BE AS FOLLOWS:
7.
(MINIMUM EMBEDMENT)
1/2"
DIAMETER
ANCHOR
THREADED
CONCRETE MASONRY
4"
5/8"
3/4"
7/8"
1"
5"
6"
7"
8"
4 1/2"
5 5/8"
6 3/4"
1/2"
CONCRETE MASONRY
5/8"
3/4"
3 1/2"
5 1/2"
ADHESIVE ANCHORS
(MINIMUM EMBEDMENT)
MECHANICAL ANCHORS
DIAMETER
ANCHOR
4 1/2"
3 1/2"
5 1/2"
4 1/2"
WITH THE MANUFACTURER'S RECOMMENDATIONS.
ANCHORS SHALL BE INSTALLED AND TORQUED IN COMPLETE ACCORDANCE
WITH THE MANUFACTURER'S RECOMMENDATIONS.
ANCHORS SHALL BE INSTALLED AND TORQUED IN COMPLETE ACCORDANCE
APPROVED EQUAL WITH ICC-ES REPORT
POWER-STUD+ SD1 BY POWERS (ICC-ES ESR-2818)
ESR-3037)
STRONG-BOLT 2 BY SIMPSON STRONG-TIE ANCHOR SYSTEMS (ICC-ES
KWIK BOLT TZ BY HILTI, INC. (ICC-ES ESR-1917)
APPROVED EQUAL WITH ICC-ES REPORT
PURE 100+ BY POWERS (ICC-ES ESR-3298)
SET BY SIMPSON STRONG-TIE ANCHOR SYSTEMS (ICC-ES ESR-1772)
HIT-HY 270 MAX BY HILTI, INC. (ICC-ES ESR-2682)
APPROVED EQUAL WITH ICC-ES REPORT
POWER-STUD+ SD1 BY POWERS (ICC-ES ESR-2966)
ESR-1396)
WEDGE-ALL BY SIMPSON STRONG-TIE ANCHOR SYSTEMS (ICC-ES
KWIK BOLT 3 BY HILTI, INC. (ICC-ES ESR-1385)
SCHEDULES, UNLESS NOTED OTHERWISE IN A SPECIFIC SECTION OR DETAIL.
PROVIDE THE MINIMUM EMBEDMENT DEPTHS INDICATED IN THE FOLLOWING
CARBON STEEL, UNLESS NOTED OTHERWISE.
ASTM A193, GRADE B7. MECHANICAL ANCHORING SYSTEMS SHALL BE ZINC PLATED
ANCHOR RODS USED IN ADHESIVE ANCHORING SYSTEMS SHALL CONFORM WITH
8.
POWDER-ACTUATED FASTENERS:
1.
FASTENERS SHALL BE MECHANICALLY ZINC COATED FOR CORROSION PROTECTION.
MATERIAL TYPES AND THICKNESSES.
THE FASTENER MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS FOR
FASTENER STYLE, PIN DEPTH, AND PIN LENGTH SHALL BE APPROVED FOR USE BY
REFERENCED CODE BY AN ICC-ES REPORT.
POWDER-ACTUATED FASTENERS SHALL BE APPROVED FOR USE WITH THE
2.
3.
APPROVED EQUAL WITH ICC-ES REPORT
PURE 100+ BY POWERS (ICC-ES ESR-3298)
SET-XP BY SIMPSON STRONG-TIE ANCHOR SYSTEMS (ICC-ES ESR-2508)
HIT-HY 200 MAX-SD BY HILTI, INC. (ICC-ES ESR-3817)
ADHESIVE ANCHORING SYSTEMS IN CONCRETE SHALL BE AS FOLLOWS:
OBSERVE INITIAL INSTALLATION OF THE ANCHORS.
SHALL TRAIN INSTALLERS ON THE PROPER INSTALLATION PROCEDURES AND SHALL
A MANUFACTURER'S TECHNICAL REPRESENTATIVE (NOT A DISTRIBUTOR OR AGENT)
RESPECTIVE ICC-ES REPORT, AND THE APPLICABLE BUILDING CODE.
EQUIPMENT MANUFACTURER'S REQUIREMENTS, THE REQUIREMENTS OF THE
TO THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, THE
INSTALLATION AND INSPECTION OF ALL POST-INSTALLED ANCHORS SHALL CONFORM
SUPPORT FASTENERS #12 TEK SCREWS
0.653
0.653
0.700
GALVANIZED G90
3.
2"
40 KSI
FINISH
Sn (in3 / ft)
Sp (in3 / ft)
I (in4 / ft)
MINIMUM YIELD STRENGTH
GAGE
DEPTH
MINIMUM COMPOSITE DECK PROPERTIES:
OR TRUSS BEARING POINT.
AXIALLY LOADED BEARING STUDS SHALL BE LOCATED DIRECTLY UNDER THE JOIST
BASED ON DESIGN LOADS.
SELF-DRILLING SCREWS. SUPPLIER SHALL SPECIFY FASTENING REQUIREMENTS
FASTENING OF COMPONENTS SHALL BE MADE WITH SUPPLIER APPROVED
FRAMING BETWEEN THE TRUSSES AND THE SUPPORT STRUCTURE.
THE METAL TRUSS MANUFACTURER SHALL DESIGN AND PROVIDE SHEAR TRANSFER
STRUCTURE, INCLUDING TRUSS UPLIFT CONNECTIONS. IF REQUIRED. ADDITIONALLY,
NECESSARY TO ADEQUATELY ANCHOR THE METAL TRUSS SYSTEM TO THE SUPPORT
THE METAL TRUSS SYSTEM MANUFACTURER SHALL DESIGN AND PROVIDE ALL ITEMS
CALCULATIONS AND SUBMIT FOR APPROVAL PRIOR TO FABRICATION.
DESIGN, THE ENGINEER SHALL AFFIX HIS SEAL TO ALL SHOP DRAWINGS AND
DESIGN OF BUILDINGS SHALL DESIGN THE MEMBERS OR DIRECTLY SUPERVISE THE
INDICATED. A REGISTERED PROFESSIONAL ENGINEER QUALIFIED IN STRUCTURAL
LATERAL LOADINGS, USING PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA
PRODUCE A COMPLETE STRUCTURAL SYSTEM, TO RESIST ALL GRAVITY AND
PROVIDE STRUCTURAL DESIGN OF ALL MEMBERS AND THEIR CONNECTIONS TO
JOISTS, WALL STUDS AND THEIR CONNECTIONS. MANUFACTURER SHALL
RESPONSIBLE FOR STRUCTURAL DESIGN OF ALL PREFABRICATED TRUSSES, CEILING
DELEGATED DESIGN: MANUFACTURER SHALL ACCOMPLISH AND BE SOLELY
FOR PROPER INSTALLATION.
SPLICES, BRIDGING, ACCESSORIES AND DETAILS OF CONNECTIONS AS REQUIRED
LOCATION AND SPACING. INDICATE ALL SUPPLEMENTAL STRAPPING, BRACING,
PLACEMENT OF FRAMING MEMBERS, SIZE AND GAGE DESIGNATIONS, NUMBER, TYPE,
FOR APPROVAL PRIOR TO FABRICATION. SHOP DRAWINGS SHALL INCLUDE
CONTRACTOR SHALL SUBMIT COMPLETE FABRICATION AND ERECTION DRAWINGS
MEMBERS", 2012 EDITION.
AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL
IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE'S "NORTH
COLD-FORMED STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION SHALL BE 1.
2.
3.
4.
5.
6.
(TRUSSES, CEILING JOISTS, STUDS)
COLD-FORMED METAL FRAMING
RECTANGULAR AND SQUARE HSS
ASTM A36
W-SHAPES AND WT-SHAPES
M-SHAPES AND S-SHAPES
50 KSI
(Fy)
ASTM A992
ASTM A36 36 KSI
ANGLES AND CHANNELS 36 KSI
ASTM A500 GRADE C
ASTM A500 GRADE C
50 KSI
46 KSI
35 KSIASTM A53 GRADE B
50 KSISTRUCTURAL PLATES ASTM A572 GRADE 50
TENSION-CONTROL BOLT ASSEMBLIES
DIRECT-TENSION INDICATORS
ASTM F1852, TYPE 1 (TWIST-OFF)
ASTM F959, TYPE 325
ASTM A563
ASTM F436
ASTM F1554 GRADE 55
SHEAR STUD CONNECTORS ASTM A29 PER ASTM A108
E70XXWELD FILLER METAL
STRUCTURAL STEEL:
SUSPENDED LOADS:
1.
STRUCTURAL SHAPES AND PLATES:
ALL ANCHOR RODS IN EXTERIOR APPLICATIONS SHALL BE HOT DIP GALVANIZED.
WITH THE MANUFACTURER'S RECOMMENDATIONS.
PROPRIETARY CONNECTIONS SHALL BE INSTALLED IN COMPLETE ACCORDANCE
CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONNECTION SYSTEM.
BEAM CLAMPS, WELDED PLATES, OR SIMILAR ATTACHMENT METHODS. THE
NOT IMPOSE ECCENTRIC LOADS UPON THE BEAM BY USING CONCENTRIC STEEL
THAN 400 POUNDS, SUSPENDED LOADS SHALL BE APPLIED IN A MANNER THAT DOES
USING BEAM "C-CLAMPS" FOR LOADS LESS THAN 400 POUNDS. FOR LOADS GREATER
SUSPENDED LOADS ATTACHED TO A BOTTOM BEAM FLANGE MAY BE ACCOMPLISHED
FASTENING PRODUCTS:
ACCORDANCE WITH THE FOLLOWING, UNLESS OTHERWISE SPECIFIED:
ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, AND ERECTED IN
AISC 360; SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS,
RCSC; SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS
CONVENTIONAL BOLTS ASTM A325, TYPE 1
TO THE STRUCTURE.
COLUMN BASE PLATES BEFORE POURING CONCRETE ON DECKS OR APPLYING LOAD
FOR COLUMNS DURING STEEL ERECTION. PLACE NON-SHRINK GROUT BELOW ALL
COLUMN ANCHOR BOLTS ARE NOT DESIGNED TO PROVIDE TEMPORARY STABILITY
PERMANENT BRACING, FLOOR SLABS, WELDED CONNECTIONS, ETC. ARE IN PLACE.
AND MAINTAIN ALL STEEL MEMBERS IN PROPER ALIGNMENT UNTIL ALL DECK,
PROVIDE ALL TEMPORARY GUYING AND BRACING NECESSARY TO ERECT, STABILIZE,
ACCORDANCE WITH TABLE 14-2 OF AISC STEEL CONSTRUCTION MANUAL.
BASE PLATE HOLES AND PLATE WASHERS FOR ANCHOR RODS SHALL BE IN
SPECIFICALLY DETAILED OR APPROVED IN WRITING BY THE C.O. / OWNER.
HOLES OR OPENINGS SHALL NOT BE CUT IN ANY STRUCTURAL MEMBER UNLESS
WELDED ALL AROUND.
OPEN ENDS OF HSS MEMBERS SHALL HAVE 1/4 INCH CLOSURE PLATES, SEAL
ALL BEAMS SHALL BE ERECTED WITH THE NATURAL CAMBER UPWARDS.
SECTION J2b
INCH OR THE MAXIMUM SIZE THAT CAN BE APPLIED IN ACCORDANCE WITH AISC 360
UNLESS NOTED OTHERWISE, FILLET WELD SIZES SHALL BE THE SMALLER OF 5/16
CERTIFIED TESTING AGENCY AND IN ACCORDANCE WITH AWS D1.1.
WELDERS SHALL BE QUALIFIED FOR EACH WPS USED ON THE PROJECT BY AN AWS
A WELDING PROCEDURE SPECIFICATION (WPS) PREQUALIFIED BY AWS D1.1.
ALL WELDING OF STRUCTURAL STEEL SHALL BE PERFORMED IN ACCORDANCE WITH
THICK MINIMUM
GUSSET PLATE THICKNESSES NOT INDICATED ON THE DRAWINGS, SHALL BE 3/8"
(+/-) 10 KIPS. PROVIDE A MINIMUM OF TWO BOLTS PER CONNECTION.
GIRT AND WIND POST CONNECTIONS SHALL BE DESIGNED FOR AN ASD LOAD OF
OF TWO BOLTS PER CONNECTION.
SHALL BE DESIGNED FOR AN ASD LOAD OF (+/-) 20 KIPS. THERE SHALL BE A MINIMUM
CONNECTIONS FOR HORIZONTAL BRACING, LACING AND SIMILAR TYPE MEMBERS
WORKLINES OF THE MEMBERS.
COMPONENTS CAN BE DELIVERED DIRECTLY TO THE INTERSECTION OF THE
BRACING CONNECTIONS SHALL BE DESIGNED AND DETAILED SO THAT ALL FORCE
3/8" THICK MINIMUM.
DIMENSION OF THE BEAM WEB. DOUBLE ANGLES OR SINGLE-PLATES SHALL BE
CONNECTIONS THAT PROVIDE THE MAXIMUM OF BOLTS THAT FIT WITHIN THE "T"
CONSTRUCTION", FOURTEENTH EDITION. CONNECTIONS SHALL BE FULL-DEPTH
CONNECTIONS AS SHOWN IN PART 10 OF THE AISC "MANUAL OF STEEL
BEAM CONNECTIONS SHALL BE STANDARD DOUBLE-ANGLE OR SINGLE-PLATE
PREPARED FOR FAYING SURFACE CLASS A.
ALL CONTACT SURFACES FOR SLIP CRITICAL TYPE CONNECTIONS SHALL BE
IN THE SHEAR PLANE. ALL HIGH STRENGTH BOLTS SHALL BE FULLY PRETENSIONED.
NOTED, CONNECTIONS SHALL BE DESIGNED AS SHEAR/BEARING TYPE WITH THREADS
CONNECTIONS SHALL BE MADE WITH 3/4" DIAMETER HIGH STRENGTH BOLTS. UNLESS
AISC 303; CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES
AWS D1.1; STRUCTURAL WELDING CODE - STEEL
16.
15.
14.
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
N O
V E
M B
E R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
-N
O V -2
:4
S T
R U
C T
U R
A L
G E
N E
R A
L N
O T
S-003
L E
S T
E R
J P
IT
T M
A N
L P
R E
S L E
Y
G
R
IG
G
IN
S
P T F
L -1
-0
-S -0
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
STRUCTURAL ABBREVIATIONS
PLUS OR MINUS
EQUALS
LESS THAN
GREATER THAN
AT
FTG
FT
FS
FLG
FL
FG
FF
FDN
FD
EXT
EXIST
EW
EQUIP
EQL SP
EQ
EOS
EOD
EMBED
ELEC
EL
EJ
EF
EA
FOOTING
FEET
FAR SIDE
FLANGE
FLOOR
FINISHED GRADE
FINISHED FLOOR
FOUNDATION
FLOOR DRAIN
EXTERIOR
EXISTING
EACH WAY
EQUIPMENT
EQUALLY SPACED
EQUAL
EDGE OF SLAB
EDGE OF DECK
EMBEDMENT
ELECTRICAL
ELEVATION
EXPANSION JOINT
EACH FACE
EACH
OSL
OPP
OPNG
OH
O.F.
OD
OC
NTS
NS
NO.
N/A
OUTSTANDING LEG
OPPOSITE
OPENING
OPPOSITE HAND
OUTSIDE FACE
OUTSIDE DIAMETER
ON CENTER
NOT TO SCALE
NEAR SIDE
NUMBER
NOT APPLICABLE
BRG
BRDG
BRCG
BP
BOSD
BOS
B.O.
BM
BLDG
BF
B/
ASD
ARCH'L
APPROX
APPD
ALUM
ALT
ADD'L
AB
BEARING
BRIDGING
BRACING
BASE PLATE
BOTTOM OF STEEL DECK
BOTTOM OF STEEL
BOTTOM OF
BEAM
BUILDING
BOTTOM FACE
BOTTOM OF
ALLOWABLE STRESS DESIGN
ARCHITECTURAL
APPROXIMATE
APPROVED
ALUMINUM
ALTERNATE
ADDITIONAL
ANCHOR BOLT
QTY
PSI
PSF
PROJ
PLF
PL
PJF
PCF
PC
PAF
QUANTITY
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
PROJECTION
POUNDS PER LINEAR FOOT
PLATE
PREMOLDED JOINT FILLER
POUNDS PER CUBIC FOOT
PRECAST
POWDER ACTUATED FASTENER
USAF
UNO
TYP
TRANS
TOS
TOF
TOC
T.O.
THK
TF
TEMP
T&B
T/
T
UNITED STATES AIR FORCE
UNLESS NOTED OTHERWISE
TYPICAL
TRANSVERSE
TOP OF STEEL
TOP OF FOOTING
TOP OF CONCRETE
TOP OF
THICKNESS
TOP FACE
TEMPERATURE
TOP AND BOTTOM
TOP OF
TREAD
JT
JST
INT
INFO
IN
I.F.
I.D.
JOINT
JOIST
INTERIOR
INFORMATION
INCH
INSIDE FACE
INSIDE DIAMETER
KSI
KSF
K
KIPS PER SQUARE INCH
KIPS PER SQUARE FOOT
KIPS
WWF
WT
WP
WL
W/O
W/
VERT
FABRIC
WELDED WIRE
WEIGHT
WORK POINT
WIND LOAD
WITHOUT
WITH
VERTICAL
DWL
DWG
DN
DL
DIM
DIAG
DIA
DBL
DBA
D
CTR
CONT
CONST
CONN
CONC
COL
C.O.
CMU
CLR
CLG
CL
CJP
CJ
CIP
CHK'D
CG
C TO C
DOWEL
DRAWING
DOWN
DEAD LOAD
DIMENSION
DIAGONAL
DIAMETER
DOUBLE
DEFORMED BAR ANCHOR
DEPTH
CENTER
CONTINUOUS
CONSTRUCTION
CONNECTION
CONCRETE
COLUMN
CONTRACTING OFFICER
CONCRETE MASONRY UNIT
CLEAR
CEILING
CENTER LINE
COMPLETE JOINT PENETRATION
CONTROL / CONTRACTION JOINT
CAST-IN-PLACE
CHECKERED
CENTER OF GRAVITY
CENTER TO CENTER
HT
HSS
HP
HORIZ
HK
HDRL
HAS
GYP
GRTG
GR
G.L.
GDRL
GB
GALV
GA
HEIGHT
HOLLOW STRUCTURAL SECTION
HIGH POINT
HORIZONTAL
HOOK
HANDRAIL
HEADED ANCHOR STUD
GYPSUM
GRATING
GRADE
GIRT LINE
GUARDRAIL
GRADE BEAM
GALVANIZED
GAGE or GAUGE
MWFRS
MTL
MISC
MIN
MFR
MECH
MB
MAX
MAT'L
MAS
LWT
LP
LONG
LNTL
LLV
LLH
LL
LG
LF
LBS
L
RESISTING SYSTEM
MAIN WIND FORCE
METAL
MISCELLANEOUS
MINIMUM
MANUFACTURER
MECHANICAL
MACHINE BOLTS
MAXIMUM
MATERIAL
MASONRY
LIGHTWEIGHT
LOW POINT
LONGITUDINAL
LINTEL
LONG LEG VERTICAL
LONG LEG HORIZONTAL
LIVE LOAD
LONG
LINEAR FEET
POUNDS
LENGTH
SYM
STRUCT
STL
STIR
STIF
STGR
STD
SQ
SPEC
SPA
SOG
SIM
SHT
SECT
SCHED
SC
RTN
REQD
REINF
REF
RECT
RD
RC
RAD
R
SYMETRICAL
STRUCTURAL
STEEL
STIRRUP
STIFFENER
STRINGER
STANDARD
SQUARE
SPECIFICATION
SPACING
SLAB ON GRADE
SIMILAR
SHEET
SECTION
SCHEDULE
SLIP-CRITCAL
RETURN
REQUIRED
REINFORCEMENT
REFER TO
RECTANGULAR
ROOF DRAIN
REINFORCED CONCRETE
RADIUS
RISER
3'-4 1/2"
A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
KEY PLAN
GRAPHIC SCALE
N O
V E
M B
E R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
N
-N
O V -2
:5
S T
R U
C T
U R
A L
V A
U L T F
L O
O R S
L A
B R
O O
F S
L A
B
F
R A
M
IN
G P
L A
N S
S-101
FOR CONSTRUCTION
K L E
S T
E R
J P
IT
T M
A N
L P
R E
S L E
Y
G
R
IG
G
IN
S
P T F
L -1
-2
-S -1
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
D7
S-510
32'-4"10"
2'-0" 2'-0"
1'-0"
(TYP 4 SIDES)
CONCRETE WALL
SEE ARCH'L
8" CMU,
32'-4"
2'-0" 2'-0"4'-2" 5 SPA @ 4'-0" 4'-2"
4"
SEE ARCH'L
BELOW,
8" CMU WALL
WALL (TYP)
CONCRETE
SPAN
W x
W x
W x
W x
D1
S-510
D1
S-510
HD
OPP
EXIST SLAB LL)
LL = 300 PSF (MATCHES
REINF W/ #7@8" EW, T&B
1'-6" CONCRETE SLAB
T/SLAB EL = 99'-11" (U.N.)
B1
VAULT FLOOR SLAB PLAN
1/4" = 1'-0" T/CONC EL = AS SHOWN ON PLAN
B5
VAULT ROOF SLAB AND FRAMING PLAN
1/4" = 1'-0"
T/STL EL = 114'-0"
LIVE LOAD = 150 PSF (STORAGE/HVAC)
1'-9" CONCRETE SLAB ON 3" FORM DECK
S-003.
FOR GENERAL STRUCTURAL NOTES, SEE SHEETS S-001 THROUGH A.
GENERAL SHEET NOTES
J
10"
J
/2
/2
3'-0"
"x
H
IG
H O
P E
N
IN
G
P O
C K
E T
(B E
M
P O
C K
E T
(B E
M x
W x
W x
W x
D7
S-510
D7
S-510
D1
S-510
D1
S-510
0 4' 8'2'
HD
OPP
EXIST SLAB LL)
LL = 300 PSF (MATCHES
REINF W/ #5@8" EW, T&B
12" CONCRETE SLAB
31'-2"
(TYP AT WALLS)
1/2" ISOLATION JOINT
EXIST SLAB
S L
O P
E D
O W
N
100'-0"
T/CONC EL.
EXIST WALL FOOTING
NEW SLAB
D4
S-510
SIM
99'-11"
T/SLAB EL.
9 10
10"
31'-2" 2'-0"
D4
S-510
D7
S-510
SIM
SPANJOINT
1/2" ISOLATION
1/2" ISOLATION JOINT
LIVE LOAD = 20 PSF (ROOF)
(10'-6" MAX CLEAR SPAN)
2" COMPOSITE DECK
4" CONCRETE SLAB ON
115'-9"
T/CONC EL
114'-4"
T/CONC EL
4"
W8x28
(TYP AT WALLS)
1/2" ISOLATION JOINT
EXIST 8" CMU WALL
3'-9 3/4"
SATISFY SHIELDING REQUIREMENTS.
REQUIRED CONDUIT PROVIDED AND DESIGNED BY USAF TO 6
EMBEDDED DOOR TRACK CHANNEL. SEE ARCHITECTURAL DWGS.5
SEE KEYED NOTES 1 & 2.
SAW CUT EXISTING 12" SLAB AT PERIMETER OF NEW SLAB SHOWN. 4
COLUMN TO SUPPORT STEEL DECK. FIELD WELD TO W14 FLANGES.
x 1'-1" LG ON EAST AND WEST SIDES OF EXISTING 4 1PROVIDE L3x3x
PROVIDE 1/2" ISOLATION JOINT BETWEEN COLUMN & CONCRETE.3
NEW SLAB TO EXISTING 12" SLAB JOINT.2
NEW SLAB TO EXISTING WALL FOUNDATION JOINT.1
KEYED NOTES
9 10
J x 7'-4 1/4"
HIGH
OPENING
3'-4 1/2"
W8x28
C5
S-521
TYP
C1
S-521
C5
S-521
SIM
C5
S-521
SIM
NOTE:
CONFIRMATION THAT SHIELDING REQUIREMENTS HAVE BEEN MET.
PERFORMED. DO NOT FABRICATE OR CONSTRUCT VAULT STRUCTURES WITHOUT USAF APPROVAL AND
WALLS AND CONCRETE ROOF SLAB THICKNESSES. SHIELDING ANALYSIS AND DESIGN HAVE NOT BEEN
VAULT WALLS AND ROOF SLAB THICKNESSES ARE BASED ON EXISTING BUILDING 2201 X-RAY VAULT CMU
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
N O
V E
M B
E R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
D1
SECTION @ VAULT WALL
1/2" = 1'-0"
D7
SECTION @ VAULT WALL
1/2" = 1'-0"
(D E
C K
PLAN
SEE 2'-0"
4'-2"2'-0"
@ FACE/WALL
W/CLOSURE
3" FORM DECK
W16
-N
O V -2
:4
S T
R U
C T
U R
A L
S E
C T
IO
N S A
N D D
E T
A
IL
S-510
K L E
S T
E R
J P
IT
T M
A N
L P
R E
S L E
Y
G
R
IG
G
IN
S
P T F
L -1
-2
-S -5
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
DETAIL
A1
S-510
@ 2'-0" OC
L4x3x1/4 (LLH) (CONT)
2@12
T/WALL JOINT
(CONT)
1/4" x 3 1/2" BAR
3/16
A1
DETAIL
3" = 1'-0"
/2
1'-0" 2'-0"
W16
DETAIL
A4
S-510
A4
DETAIL
3/4" = 1'-0"
2'-0"
10"
2"
6"
2"
W16
5 1/2" GAGE
ANCHOR BOLTS ON
BRG PL 1/2"x6"x0'-9"
GROUT
1" NON SHRINK
3"
EL 115'-9"
T/CONC
EL 115'-9"
T/CONC
2'-0"
T&B
#7@12"
(TYP EF)
1" CLR
T&B
#7@8"
CORNERS, HORIZ BARS, TYP)
#7@12" EF, (STD HOOK @(TYP EF)
1" CLR
C L
R
C L
R
C L
R
C L
R
T&B
#7@12"1
C L
R
C L
R
T&B
#7@8"
(T Y
P
C L
R
(T Y
P
C L
R
NOTE: REINF NOT SHOWN FOR CLARITY.
L A
P
C L
A S
S B
WALL JOINT
SLAB
EXIST
L A
P
C L
A S
S B
T/CONC EL 99'-11"
EL 115'-9"
T/CONC
/2
FACE OF OPENINGS)
HORIZ BARS AT VERTICAL
T/OPENINGS & HOOK #7
(HOOK #7 VERT BARS ABOVE
CORNERS, HORIZ BARS, TYP)
#7@12" EF, (STD HOOK @
WALL JOINT
W/ROOF SLAB POUR
FILL BEAM POCKET
A7
NEW TO EXIST SLAB CONST JT
1 1/2" = 1'-0"
AGGREGATE AND COMPACT. SEE FOUNDATION NOTES, S-001.
REMOVE 6" OF EXIST 14" OF DENSE GRADED
10"
SEE DETAIL A7/S-510
SMOOTH ADHESIVE DOWEL.
SLOPE
T/CONC EL 99'-11"
SLOPE WP (EL 99'-11")
EL 114'-4"
T/CONC & WALL JOINT
JOINT
1/2" EXP
DECK
2" COMPOSITE
4" SLAB ON
3" FORM DECK
WALL FDN
EXIST SLAB/
PROVIDE PLASTIC END CAP W/1/8" VOID
PAINT AND GREASE END IN NEW CONCRETE.
NEW SLAB
FILL W/ EPOXY JOINT FILLER.
SAW CUT 1/8"x2" DEEP.
D4
SECTION @ CMU WALL
1/2" = 1'-0"
2'-0"3'-0"
WALL FDN
EXIST
EL 100'-0"
T/CONC
CMU WALL
EXIST 8"
EL 114'-4"
T/CONC
W8
W8
1/2" EXP JOINT
(1" FROM T/SLAB)
REINF. W/ 6x6-W2.9xW2.9 WWF
4" SLAB ON 2" COMPOSITE DECK
J 1'-5"
4 1/2"
DETAIL A7/S-510.
PROVIDE NEW ADHESIVE DOWELS PER
SMOOTH DOWELS TO REMAIN OR
PROVIDE NEW CAP
EXIST SLOPE WP (EL 100'-0")
SLOPE
10"
SEE SHEETS S-001 THROUGH S-003.
FOR GENERAL STRUCTURAL NOTES, 1.
NOTES:
DECK
3" FORM
REINF. BETWEEN BEAMS
ABOVE OPENING)
#4 CLOSED TIES @ 6" (ONLY
WIDE DOOR OPENING. PROVIDE
REINF CENTERED OVER 9'-10"
PROVIDE 8 - ADD'L #7 x 22'-0" LG.
EXIST AGGREGATE
W8
W8
4 1/2"
EXIST AGGREGATE
VAPOR RETARDER
VAPOR RETARDER
LAP SPLICE
2'-7"
2 2
EXIST AGGREGATE
VAPOR RETARDER
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
N O
V E
M B
E R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
INTERSECTION CORNER OPENING OR END OF PANEL CONTROL JOINT
SOLID)
REINFORCING (GROUT CORES
TYPICAL VERT WALL
VERTICAL BARS SAME SIZE AS
DETAILS
LOCATIONS AND CJ
SEE ARCH'L DWGS FOR CJ
SOLID)
REINF (GROUT CORES
SIZE AS TYP VERT WALL
VERTICAL BARS SAME
JOINT
CONTROL
SOLID)
REINF (GROUT CORES
SIZE AS TYP VERT WALL
VERTICAL BARS SAME
PARTITION WALL
EXTERIOR OR
SOLID)
REINF (GROUT CORES
SIZE AS TYP VERT WALL
VERTICAL BARS SAME
PARTITION WALL
CONTROL JOINTS.
CORNER
RUN CONTINUOUS ACROSS
BOND BEAM REINF SHALL
NOTE:
INTERSECTION
REINF
2-#5 BOND BEAM
BEAM REINFORCING.
BARS SAME SIZE AS TYP BOND
PROVIDE ADDITIONAL CORNER
(TYP)
24 BAR DIA
D
IA
T Y
P
B
R
(TYP)
24 BAR DIA
(TYP)
24 BAR DIA
CONT
CMU BOND BEAM
EA SIDE OF JOINT
ADD'L VERT REINF AT
D
IA
T Y
P
B
A R
FOR LOCATION
SEE ARCH'L PLAN
OR CONTROL JOINT,
EXPANSION JOINT
G E
N E
R A
L N
O T
E S
S P
L
IC
E S
SEE PLAN
T/CONC
GENERAL NOTES
CONCRETE
DOWELS, SEE
EPOXY REBAR
PIER
GROUT CONT
COURSE, REINF &
BOND BEAM TOP
& GENERAL NOTES
SEE LINTEL SCHEDULE
EA SIDE MIN.
BARS EACH CELL). PROVIDE 1-#5
(1/2 EACH SIDE OF OPENING W/2
BARS INTERRUPTED BY OPENING
OPENINGS EQUAL TO NUMBER OF
PROVIDE REINF @ JAMB OF WALL
& INTERSECTIONS
WALL ENDS, CORNERS
ADD'L VERT REINF AT
SEE SCHEDULE
VERT REINF
(ALL OTHERS)
1 LAYER REINF
VERT REINF
AND @ 4' OC BETWEEN.
1 COURSE BELOW TOP OF WALL
LOCATE @ TOP OF 1ST COURSE,
BAR POSITIONER.
VERT REINF
AND @ 4' OC BETWEEN.
1 COURSE BELOW TOP OF WALL
LOCATE @ TOP OF 1ST COURSE,
BAR POSITIONER.
DOWEL
2 LAYER REINF
/2
"DOWEL
AND SPACING
HORIZONTAL REINFORCEMENT
WALL THICKNESS
NOMINAL
CMU WALL REINFORCING SCHEDULE
AND SPACING
VERTICAL REINFORCEMENT
A. SEE ARCH'L DWGS FOR WALL LOCATIONS.
WALL TYPE NOTES:
WALL DESCRIPTION (LOCATION)
LC CELL
LC CELL
LC
A L L
A2
WALL REINFORCING DETAILS
NTS
TYPICAL MASONRY VERTICAL
A5
REINFORCING DETAILS
NTS
TYPICAL BOND BEAM
D7
VERTICAL REINF PLACEMENT
NTS
TYPICAL
D2
TYP REINFORCING DIAGRAM
NTS
CMU WALL
#5 @ 24"8" LADDER TYPE @ 16"
-N
O V -2
:4
S T
R U
C T
U R
A L
C O
N C
R E
T E M
A S
O N
R Y
S E
C T
IO
N S A
N D D
E T
A
IL
S
S-520
FOR CONSTRUCTION
K L E
S T
E R
J P
IT
T M
A N
L P
R E
S L E
Y
G
R
IG
G
IN
S
P T F
L -1
-2
-S -5
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
ADD'L BARS AS REQD
NOTES:
(T
Y P
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
N O
V E
M B
E R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
N O
M
IN
A L
D E
P T
H
NOMINAL DEPTH)
COURSES TO ATTAIN SPECIFIED
SUFFICIENT NUMBER OF
8" DEPTH CMU (PROVIDE
THK
WALL
TYPE A
EACH SIDE OF OPENING
PROVIDE 8" BEARING
8" DEPTH CMU LINTEL COURSE
/2
TYPE B
(M
IN
/2 (M
A X
/2
CHANNEL W/STUDS
EACH SIDE OF OPENING
PROVIDE 8" BEARING
THK
WALL
N O
M
IN
A L
D E
P T
H
/2 (M
IN
/2 (M
A X
LINTEL DEPTH
NOMINAL
WALL THICKNESS
NOMINAL
CLEAR SPAN
NOMINAL
8" UP TO 4'
8" UP TO 8'
TYPE
A,B
CMU LINTEL SCHEDULE
REINFORCEMENT
BOTTOM
REINFORCEMENT
TOP
8" 2-#4 NONE REQUIRED
16" 2-#4 2-#4
REMARKS
-N
O V -2
:4
S T
R U
C T
U R
A L
C O
N C
R E
T E M
A S
O N
R Y
S E
C T
IO
N S A
N D D
E T
A
IL
S
S-521
FOR CONSTRUCTION
K L E
S T
E R
J P
IT
T M
A N
L P
R E
S L E
Y
G
R
IG
G
IN
S
P T F
L -1
-2
-S -5
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
A,B
NOTES:
2"
ON BEAM GAGE
BEARING PL 1/2"x4"x0'-6 1/2"
W8
T/SLAB EL 114'-4"
C1
SECTION
NTS
C5
SECTION
NTS
T/SLAB EL 114'-4"
(TYP ALL WALLS)
STUDS@2'-0" OC
PL 1/4"x3"xCONT
(ATTACH TO PL 1/4")
2" COMPOSITE DECK
8" CMU
8" CMU
2 1/2"
TOP RAILING
2'-0"
0'-6" 0'-6"
18" CLEAR
7"
A-601
A5
6" HEIGHT CONTAINMENT CURB 6" CMU
(OPT. 6" POURED IN PLACE CONCRETE)
EPOXY PAINT FLOOR SURFACE AND 6" MIN
UP WALL SURFACE (ALL AROUND) MATCH
EXISTING HAZ MAT ROOM FLOOR FINISH
RUBBER MAT FLOORING (BY OTHERS)
2-HR. FLOOR CEILING ASSEMBLY W/ GWB &
METAL STUD JOISTS (UL DESIGN K506)
SEE DETAILED DESCRIPTION ON SHEET A-201
H.M. DOOR AND FRAME
EXISTING 2-HR FIRE RATED CONCRETE FLOOR/CEILING ASSEMBLY
(BEYOND AT EXISTING HAZMAT RM.)
A-301
E6
T.O. NEW WALL
13'-9 1/4"
T.O. DOOR FRAME
7'-4"
T.O. EXIST SLAB
0'-0"
B.O. CLG
12'-0"
NEW 1 1/2" Ø SCH 40 STEEL PIPE GUARDRAIL PAINTED
'SAFETY YELLOW'' AT EXISTING CONC HAZ MAT LID
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
BOLLARD?
STL. BOLLARD PIPE, TYP.
6" DIA. SCHED. 40 CONC. FILLED
3/4" X 1'-6"X1'-6" BASE PLATE
ANCHOR
CONC. FLOOR
3/4" NONSHRINK GROUT
6"
EL 0'-0"
A - ELEVATIONB - SECTION
BOLT THE LADDER DIRECTLY TO CMU
BOLT THE LADDER TO CONCRETE FLOOR
3'-0"
CMU WALL
FACE OF EXISTING
LADDER
NEW STEEL PUDDLE WELD IN PLACE
DRILL PLATE FOR RUNGS AND
3/8" X 2 1/2" STEEL PLATE SIDE RAILS
RUNGS @ 12" CC (TYPICAL)
AT EXISTING CONC HAZ MAT LID
GUARDRAIL PAINTED 'SAFETY YELLOW''
NEW GUARDRAIL BEYOND
2'-3"
E
X
IS
T
IN
G V
E R
IF
Y I
N F
IE
L D
PER STRUCTURAL
ADHESIVE ANCHORS
TO BOND BEAM WITH
MTL RAILING ATTACHED
WITH CONCRETE
BOND BEAM FILLED
CONCRETE "U" BLOCK
8" CMU
DOWELS @ 24" O.C. MAX
MEZZANINE
EXIST HAZMAT
12' AFF@
2-HR CEILING
CONCRETEBOND BEAM
GENERAL SHEET NOTES
A. SEE SHEET A-601 FOR DOOR SCHEDULE.
B. SEE SHEET A-201 FOR 2HR FIRE RATED CEILING ASSEMBLY
DETAIL.
C. SEE SHEET A-112 FOR BOLLARD LOCATION (ADJACENT TO
VAULT ROOM #180).
D. SEE STRUCTURAL GENERAL NOTES REFERENCED AS
"POST-INSTALLED ANCHORS"
-O
C T -2
:0
A R
C H
IT
E C
T U
R A
L
W A
L L S
E C
T
IO
N
A-301
FOR CONSTRUCTION
M J
O H
N S
O N
J .O
C A
S
IO
S A
N G
E R
H A
U S
E N
G
R
IG
G
IN
S
P T F
L -1
-2
-A -3
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-3
F6
TYP.INT. BOLLARD SECTION DETAIL
SCALE: 1"=1'-0"
A5
BUILDING SECTION -HAZMAT STORAGE
SCALE: 3/8"=1'-0"
A1
LADDER DETAIL
SCALE: 3/8"=1'-0"
4'0 2' 8'
E6
TYP.INT. BOLLARD SECTION DETAIL
SCALE: 1"=1'-0"
M. Johnson Stamp
4"
BRACKET
LOCK JOINT
DOOR HANGER
VAULT
FROM EXISTING
DOOR RELOCATED
EXISTING VAULT
TOP TRACK
C
L DOOR
DOOR THICKNESS
BOLT DIAMETER AND SPACING
ANCHOR TO MATCH EXISTING
THREADED ROD AND ADHESIVE
TYPICAL ANCHOR BOLT:
STRUCT DWGS
NEW CONC WALL, SEE
DOOR GUIDE
CHANNEL TRACK
NEW FLOOR
T.O. CONC SLAB
11'-10"
B.O. CONC (DOOR OPNG)
CENTERLINE OF BOLT
3"
2 HR FIRE RATED - UL DESIGN NO. U905
8" CMU WALL
8" CMU WALL
1A
GYP. BD. PARTITION
FULL HT. STUDS, GYP. BD.
8" CONCRETE MASONRY UNIT
FIN. FLOOR FIN. FLOOR
3" SOUND BATT INSUL
FIRESTOPS AT FIRE RATED WALLS.
SEALANT - PROVIDE 1-HR. OR 2-HR.
8" CMU WALL-2 HR FIRE RATED 1A
24" WALL
( SEE STRUCTURAL)
24" CONCRETE WALL
JOINT REINF. @ 16" O.C.
HORIZONTAL TRUSS TYPE
IF SCHEDULED
WALL BASE
AS SCHEDULED
LINE OF CEILING
FIN. FLOOR
BASE AS SCHEDULED
SIDE
1 LAYER 5/8" GWB EA.
AT 16" O.C.
3 5/8" METAL STUDS
AS SCHEDULED
CEILING
GWB AT ALL WET AREAS (TYP)
USE MOISTURE RESISTANT
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
(TYPICAL)
POSTS, TYP.
STL. PLATE WELD TO STL.
"(THK.) 4
1TOE KICK: 2"(H) X
EXIST 8" CMU
SLAB ON 2" STL DECK
1 2
POST @ 5'-0" (MAX)
1/4" FROM T/CONC
1/4" x 4" TOE PL
ANCHORS @ 5'-0" OC
PL 3/4" x 4" x 0'-8" w/
STORAGE ROOM
EXISTING HAZ MAT
5/16"
GENERAL SHEET NOTES
A. SEE SHEET A-601 FOR DOOR SCHEDULE.
B.MOVE EXISTING VAULT DOOR TO ROOM 180 AND ADD NEW
FLOOR CHANNEL.
C.SEE STRUCTURAL GENERAL NOTES REFERENCED AS
"POST-INSTALLED ANCHORS"
A1
VAULT DOOR HEAD/SILL DETAIL
SCALE: 3"=1'-0"
A4
WALL TYPES
SCALE: 1"-1'-0"
0 1' 2'6"
0 2' 4'1'
C4
GUARDRAIL SECTION & ELEV
SCALE: 1/2"=1'-0"
6"0 3" 1'
-O
C T -2
:0
A R
C H
IT
E C
T U
R A
L
W A
L L S
E C
T
IO
A-310
FOR CONSTRUCTION
M J
O H
N S
O N
J .O
C A
S
IO
S A
N G
E R
H A
U S
E N
G
R
IG
G
IN
S
P T F
L -1
-2
-A -3
.d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-3
MECH.
HANGAR BAY
BEARING
CLEANING
ROOM
FIRE PROTECTION
MEN
LOBBY
OFFICE
OFFICE
JAN.
WOMEN
CONF.
ADMIN.
VEST.
ELEC./
400 HZ.
REPAIR &
RECLAMATION SHOP
ADMIN.
ADMIN.
CTK.
ELECT. COMM.
GENERATOR
TEST STAND
ADMIN.
CTK.
COMM.
LOX CART
REPAIR
PNEUDRAULICS SHOP
ELEN SHOP
DIFM
SPIN RIVETER HAZ MAT
NI-CAD
BATTERY
LEAD ACID
BATTERY
OXYGEN
CO2
ADMIN.
ADMIN.
CTK.
CTK.
MACHINE SHOP
WELDING SHOP
CORROSION CONTROL/
COMPOSITE SHOP
PAINT BOOTH
WASH
STOR.
MEDIA BLASTER
COMM.
ADMIN. CTK.
CLEAN ROOM
SHEET METAL SHOP
STAIR
BOTTLE
STOR.
BOTTLE
STOR.
LOCKER ROOM
UP
PN-SPIN RIVETER
256T
E
3.2 14 12.62.6
M
J
L
K
H
E
F
G
D
C
B
M
L
K
J
H
G
F
D
C
B
6 3 4 5 7 8 9 10 11 12 13 14
A A
C.1
D.1
J.8
K.6
L.3
K.5
1 2 3 4 5 6 7 8 9 10 11 12 13 13.3
K.7
11.4
K.7
10.8
F.3
H.6
4.2
C.7
3.7
D.3
9.4 9.8
J.9
7.2 7.8 11.4
J.1
145 143
109.89.4
G
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
N
SEE SHEET FA001 FOR SYMBOLS, ABBREVIATIONS AND GENERAL NOTES.A.
GENERAL SHEET NOTES
SHEET KEYNOTES
C3
FIRST FLOOR FIRE ALARM DEMOLITION PLAN
SCALE: 1/32" = 1'-0"
-N
O V -2
:3
D E
M O
L
IT
IO
N
F
IR
E A
L A
R M
F
IR
S T F
L O
O R D
E M
O L
IT
IO
N P
L A
N
FD110
FOR CONSTRUCTION
B P
E A
B O
D Y
M
M
IK
L A
N C
IC
G
R
IG
G
IN
S
G
R
IG
G
IN
S
P T F
L -1
-2
-F
D .d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
C
O M
M E
N T C
L O
S U
R E
-3
32' 64'0
B4
F401
A3
ENLARGED FIRE ALARM DEMOLITION PLAN
SCALE: 1/32" = 1'-0"
A6
ENLARGED FIRE ALARM DEMOLITION PLAN
SCALE: 1/32" = 1'-0"
A3
FD110
A6
FD110
2 2
ELEC./
400 HZ.
VAULT
PROCESSING
176 178
CONTROL
VIEWING
OFFICE
OFFICE
ELEC.
COMM.
TRAINING
VEST
LOCKER ROOM
VENDING
BREAK ROOM
NDI SHOP
CTK
STORAGE
MPO
& STORAGE
SHOP STOCK
TRAP
LIGHT
HAZ MAT STORAGE
HAZ MAT STORAGE
AHU-2-2
ACU-2-1
G
9 9.4 9.8 10 1
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
S E
P T
E M
B E
R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
N
S
SEE SHEET F-001 FOR SYMBOLS, ABBREVIATIONS AND GENERAL NOTES.A.
GENERAL SHEET NOTES
SHEET KEYNOTES
EXISTING HAZMAT ROOM.8.
NEW HAZMAT ROOM.7.
ALL DEVICES IN SPACE SHALL BE NEW.6.
EXISTING TO REMAIN FIRE ALARM DEVICES.5.
FOAM SYSTEM.
RELOCATED MANUAL RELEASE AND SPEAKER STROBE FOR HIGH EXPANSION 4.
ENVIRONMENTS.
ALL FITTINGS AND DEVICES SHALL BE U.L. LISTED FOR CLASS I DIVISION II
EXTEND EXISTING FIRE ALARM CIRCUIT TO INCLUDE NEW HEAT DETECTOR. 3.
ACU-2-1 ON MEZZANINE LEVEL.
PROVIDE NEW DUCT TYPE SMOKE DETECTOR ON SUPPLY SIDE OF NEW 2.
DIVISION 2.
PROVIDE FIXED TEMPERATURE HEAT DETECTOR U.L. LISTED FOR CLASS I, 1.
A1
FIRST FLOOR FIRE ALARM PLAN - AREA B
SCALE: 3/32" = 1'-0"
A5
FA401
D5
NEW HAZMAT ROOM
SCALE: 1/4" = 1'-0"
-N
O V -2
:3
F
IR
E A
L A
R M
E N
L A
R G
E D P
L A
FA401
B P
E A
B O
D Y
M
M
IK
L A
N C
IC
G
R
IG
G
IN
S
G
R
IG
G
IN
S
P T F
L -1
-2
-F
A .d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
A
M E
N D
M E
N T
-0
-1
C
O M
M E
N T C
L O
S U
R E
-3
0 4' 8'2'
0 8' 32'16'
A5
NEW AHU - MEZZANINE LEVEL
SCALE: 1/4" = 1'-0"
KJ
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
J U
L Y
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
N
-A
U G -2
:5
M E
C H
A N
IC
A L
H V
A C S
E C
T
IO
MH301
FOR CONSTRUCTION
E
C A
R R
O L L
D F
L O
Y D
J
C O
E N
G
R
IG
G
IN
S
P T F
L -1
-2
-M
H .d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -0
GENERAL SHEET NOTES
SHEET KEYNOTES
MAINTENANCES.
INSTALL FAN MOTOR SUCH THAT IT IS EASILY ACCESSIBLE FOR 1.
NOTES.
SEE SHEET M-001 FOR SYMBOLS, ABBREVIATIONS AND GENERAL A.
C2
SECTION
SCALE: 1/4" = 1'-0"
0 4' 8'2'
12x8 OA(E)
12x8 OA
4"-LPS(E)
1 1/2"-CWS(E)
1 1/2"-CWR(E)
4"-HWS(E)
4"-HWR(E)
18x18 SA
ACU-2-1
1"-HWR (E)
1"-HWS (E)
1 1/4"-CWR (E)
1 1/4"-CWS(E)
D6
SECTION
SCALE: 1/4" = 1'-0"
10x10 SA(E)
10x10 SA 8"x8" EA
200CD
FD
200EG
EF-9-1
"x
E A
"x
E A
M A
X
C5
MH501
A P
P R
O X
BIRDSCREEN
HAZ. MAT. STORAGE
1"-HWR
1"-HWS
1 1/4"-CWR
1 1/4"-CWS
E1
MH501FLOOR DRAIN
EXISTING
E8
MH501
EXH FAN EF-2
PROCESSING
FROM
8x8 EXH
LOUVER
PLENUM &
12x12 EXH
B1
MH501
PAD
HOUSEKEEPING
4"
TRAINING
COMM.
VEST
ELEC.
OFFICE
OFFICE
PROCESSING
TRAP
LIGHT
CONTROL
400 HZ.
ELEC./
VIEWING
SHOP
NDI
CTK
MPO
& STORAGE
SHOP STOCK
STORAGE
BREAK ROOM
LOCKER ROOM
LINE
PENETRANT
DYE
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
N O
V E
M B
E R
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
N
T
T
X X
X
PIPE SUPPORTS NOT SHOWN THIS PLAN. INSTALL PER 23.D.
DUCT HANGERS NOT SHOWN THIS PLAN. SUSPEND DUCT PER 23.C.
ACCORDANCE WITH 23.
DUCT INSULATION NOT SHOWN THIS PLAN. INSULATE IN B.
GENERAL NOTES.
SEE SHEET M-001 FOR SYMBOLS, ABBREVIATIONS ANDA.
GENERAL SHEET NOTES
SHEET KEYNOTES
VIA 12"x12" DISCHARGE LOUVER.
DISCHARGE TO ATMOSPHERE OUT SIDEWALL ABOVE LOW ROOF
ACCESSIBLE LOCATION ABOVE ROOM CAP. ROUTE DUCT UP AND
8"x8" EXHAUST AIR FROM PROCESSING. LOCATE EXHAUST FAN IN 12.
EI-MH-501 FOR P-TRAP DETAIL.
IMMEDIATELY IN FRONT OF COOLING COILS. REFER TO DETAIL
CONNECTION TO EXISTING FLOOR DRAINS LOCATED
ROUTE 3/4" CONDENSATE DRAIN FROM COIL DRAIN PAN 11.
IN SUPPLY DUCT OF ACU-2-1 ONLY.
MOUNT DUCT SMOKE DETECTOR (DSD) IN ACCESSIBLE LOCATION 10.
SEE ENLARGED PLAN A4 ON THIS SHEET FOR CONTINUATION.9.
ABOVE NEW CEILING.
DROP DUCT DOWN APPROXIMATELY 18" BOTTOM OF DUCT 8.
ADDITION.
DROP DUCT DOWN THROUGH CAP INTO CEILING OF NEW ROOM 7.
HORIZONTAL RUNS ON TOP OF NEW ADDITION.
DROP DUCTS DOWN AS CLOSE TO WALL AS POSSIBLE. INSTALL 6.
IN ROOF.
DROP DUCT DOWN THRU ROOF OF EXIST VAULT. PROVIDE OPEN 5.
UNIT.
CONNECT NEW CHW BRANCH PIPING TO MAINS AND EXTEND TO 4.
CONNECT UNITS TO EXIST. CHW SUPPLY AND RETURN. 3.
CONNECT UNITS TO EXIST. HW SUPPLY AND RETURN. 2.
DRAINS.
DIMENSIONS AND 2" TOERAIL. DO NOT COVER EXISTING FLOOR
PROVIDE ADDITIONAL CONCRETE TO 4" GREATER THAN UNIT
INSTALL NEW AIR HANDLING UNITS ON EXIST. CONCRETE PADS 1.
9 9.4 9.8 10
J
J.8
H.6
J
J.8
K
K.5
L
L.3
M
C5
ENLARGED FIRST FLOOR HVAC PLAN - NON-DESTRUCTIVE ANALYSIS
SCALE: 1/8"-1'-0"
0 8'4' 16'
-N
O V -2
:3
M E
C H
A N
IC
A L
E N
L A
R G
E D H
V A
C P
L A
MH401
E
C A
R R
O L L
D F
L O
Y D
J
C O
E N
G
R
IG
G
IN
S
P T F
L -1
-2
-M
H .d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -2
-1
R
E S
P O
N S
E T
O C
L
IE
N T C
O M
M E
N T S
-0
-1
A
M E
N D
M E
N T
-1
-1
A4
ENLARGED MEZZANINE HVAC PLAN - NON DESTRUCTIVE ANALYSIS
SCALE: 1/4"-1'-0"
9.4 9.8 10 11
0 4' 8'2'
16x12 x x
8x6
190CD-8
8x6175CD-8
DN
x
8x6
105CD(E)
105CD(E)
16x10
16x10 16x12 x x
350CD-10
TYP.4
170CD(E)
170CD(E)
100CD(E)
170CD(E)
170CD(E)
125CD(E)
x (E x
100CD(E)
50CD(E)
50CD(E)
x
8x6 x
DN 160CD-6
DN
235CD-8
16x12
DN
7TYP.
2 2 3 x x
1 1 x x
12x6 12x8
DSD
TURNING VALVES TYP.
x (E
9 9 x
1"-HWS/R
1 1/4"-CWS/R
1 "-CWS/R
1"-HWS/R
E8
MH501
D2
MH301
TYP. 4
x
EF-2
x
E5
MH501
TYP.
B1
MH501
C5
MH501
220RG-1
MAINTENANCE & COIL
PULL CLEARANCE
MAINTENANCE & COIL
PULL CLEARANCE
AHU-2-2 ACU-2-1
(E) 4"-LPS
(E) 4"-HWR
(E) 4"-HWS
(E) 1 1/4"-CHWR
(E) 1 1/4"-CHWS
MATCHLINE. SEE
ENLARGED PLAN C3,
THIS SHEET, FOR CONT.
315RG(E)90RG(E)
90RG(E)
100CD(E)
95RG(E)
205RG-1160RG-1
275RG(E)
1380RG-5
130RG-1
R E
S P
O N
S E T
O C
L
IE
N T C
O M
M E
N T S
-0
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
J U
L Y
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
3/4" DRAIN W/GATE VALVE
3/4" COIL DRAIN VALVE
W/HOSE COUPLING
& HOSE COUPLING
AIR VENT (3/4" GATE
SEPARABLE SOCKET
THERMOMETER WITH
COOLING COIL
VALVE W/PLUG
COIL AIR VENT
HOT WATER OR
VALVE WITH CAP)
PIPING
Y-STRAINER w/
BLOW-OFF VALVE
W/GATE VALVE
PRESSURE GAUGE
1-1/2") GATE VALVE
BALL VALVE (UP TO
(2" & OVER)
VALVE
BALANCING
REDUCER
PIPING
CHWS & HWS
CHWR & HWR
UNION
3-WAY MODULATING VALVE
FOR DETAIL
ARCHITECTURAL DWGS
LOUVER REFER TO
INTAKE / EXHAUST
BIRDSCREEN
1/2" MESH
EXTERIOR WALL
MINIMUM
DUCT FOR FIRST 4'
EXTERIOR INSULATE
DOOR
ACCESS
OUTSIDE FOR DRAINAGE.
(MINIMUM) PER FOOT TO
PLENUM DOWN 4"
PITCH BOTTOM OF
PLENUM
EXTERIOR INSULATED
INDICATED ON DWGS
BACKDRAFT DAMPER IF
POSSIBLE
PLENUM AS HIGH AS
CONNECT DUCTS TO
AREA
WATERTIGHT IN THIS
CAULK ALL JOINTS
SUPPORT PLENUM BOTTOM
BOLTS EXTEND FRAME TO
FRAME TO WALL WITH ANCHOR
ANCHOR WELDED ANGLE-IRON
FLOW
AIR
SHOWN ON DWGS
12" MINIMUM OR AS
FLOW
AIR
DRAINAGE
BLADE OF LOUVER FOR
TO OVERLAP BOTTOM
EXTEND PLENUM BOTTOM
EXHAUST DUCT
FAN MOTOR
EXHAUST FAN
SPRING ISOLATORS
FLEXIBLE CONNECTION
MOTOR COVER
(TYPICAL)
FASTEN TO STRUCTURE
ARCHITECT ON HOW TO
COORDINATE WITH SUPPORTS
HANGER
DUCT
DIAMETERS OF STRAIGHT
ALLOW 2 1/2 INLET
DUCT
DIAMETERS OF STRAIGHT
ALLOW 2 1/2 OUTLET
D
IR
E C
T
IO
N O
F
A
IR
F
L O
W
BRANCH DUCT
(S U
P P
L Y A
IR
45 DEG
0.25 BRANCH WIDTH
0R 75mm MIN.
MANUAL OPPOSED BLADE DAMPER
WITH LOCKING QUADRANT
D
IR
E C
T
IO
N O
F
A
IR
F
L O
W
T R
U N
K D
U C
T
(R E
T U
R N O
R
E X
H A
U S
T A
IR
INSULATION (WHERE APPLICABLE)
COIL
UNIT DRAIN PAN
UNION
CAP-2 PLACES
=UNIT TSP+2"
=UNIT TSP
PIPE SIZE EQUAL TO
DRAIN CONNECTION SIZE
TO DRAIN
FIG. A
FIG. B
DUCT
DUCT
AIR FLOW
AIR FLOW
CONTROL.
GRILLE HAS NO VOLUME
CONTROL AT GRILLE.
DIFFUSER CONTAINS VOLUME
NOTE:
SUPPLY/RETURN
DIFFUSER
ADJUSTABLE DAMPER
(DIFFUSER ONLY)
COLLAR
CEILING
WALL OR
45° ENTRY
45° ENTRY
COLLAR
SUPPLY/RETURN
DIFFUSER
A
IR
F
L O
W A
IR
F
L O
W
CHILLER
VIBRATION ELIMINATOR (TYP.)
(TYP.)
PRESSURE INDICATOR
(TYP.)
THERMOMETER STRAINER
BUTTERFLY VALVE (TYP.)
5" CHWR
5" CHWS
BALANCING VALVE
FLANGE
NC
NC
VENT (TYP.)
CHECK VALVE
TANK
EXPANSION
PUMP
FURNISHED WITH CHILLER
PUMP PACKAGE
-A
U G -2
:5
M E
C H
A N
IC
A L
H V
A C D
E T
A
MH501
J
G A
R N
E R
D F
L O
Y D
J
C O
E N
G
R
IG
G
IN
S
P T F
L -1
-2
-M
H .d w g
IS
S U
E F
O R C
O N
S T
R U
C T
IO
N -0
E8
AIR HANDLING UNIT COIL PIPING DETAIL
SCALE: NONE
B8
DIFFUSER / GRILLE CONNECTION DETAIL
SCALE: NONE
B1
WALL-MOUNTED LOUVER DETAIL
SCALE: NONE
C5
IN-LINE EXHAUST FAN DETAIL
SCALE: NONE
E5
TYPICAL DUCT BRANCH TAKEOFF DETAIL
SCALE: NONE
E1
TYPICAL CONDENSATE DRAIN PIPE DETAIL
SCALE: NONE
A5
100 TON CHILLER PIPING DETAIL
SCALE: NONE
MECH.
HANGAR BAY
BEARING
CLEANING
ROOM
FIRE PROTECTION
MEN
LOBBY
OFFICE
OFFICE
JAN.
WOMEN
CONF.
ADMIN.
VEST.
ELEC./
400 HZ.
REPAIR &
RECLAMATION SHOP
ADMIN.
ADMIN.
CTK.
ELECT. COMM.
GENERATOR
TEST STAND
ADMIN.
CTK.
COMM.
LOX CART
REPAIR
PNEUDRAULICS SHOP
ELEN SHOP
DIFM
SPIN RIVETER HAZ MAT
NI-CAD
BATTERY
LEAD ACID
BATTERY
OXYGEN
CO2
ADMIN.
ADMIN.
CTK.
CTK.
MACHINE SHOP
WELDING SHOP
CORROSION CONTROL/
COMPOSITE SHOP
PAINT BOOTH
WASH
STOR.
MEDIA BLASTER
COMM.
ADMIN. CTK.
CLEAN ROOM
SHEET METAL SHOP
STAIR
BOTTLE
STOR.
BOTTLE
STOR.
LOCKER ROOM
UP
PN-SPIN RIVETER
256T
3.2 14 12.62.6
M
J
L
K
H
E
F
G
D
C
B
A
C.1
D.1
J.8
K.6
L.3
K.5
1 2 3 4 5 6 7 8 9 10 11 12 13 13.3
K.7
F.3
H.6
9.4 9.87.2 7.8 11.4
VAULT
HYDRO WARP MAINTENANCE
145 143
PROCESSING
176 178
CONTROL
VIEWING
OFFICE
OFFICE
ELEC.
COMM.
TRAINING
VEST
LOCKER ROOM
VENDING
BREAK ROOM
NDI SHOP
CTK
STORAGE
MPO
& STORAGE
SHOP STOCK
HAZ MAT STORAGE
HAZ MAT STORAGE
TRAP
LIGHT
T A
S K O
R D
E R N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
S C
A L E
S H
E E
T
D R
A W
IN
G C
O D
E
O F
K C -4
A B
E D
D O
W N
M C
G U
IR
E A
F B
B U
R L
IN
G T
O N C
O U
N T
Y
N E
W J
E R
S
E
R -1
-D -0
J U
L Y
A N
S I
D :1
L
A K
E S
ID
E C
E N
T R
E W
A Y
S U
IT
E
K N
O X
V
IL
L E T
N
N
GENERAL NOTES.
SEE SHEET M-001 FOR SYMBOLS, ABBREVIATIONS AND A.
GENERAL SHEET NOTES
SHEET…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.