Amendment_3_-_Appendix_A_-_As-Build_Drawings.pdf
PDF 22 MB Posted
- Attached to
- KC-46A Alter Facilities for Maintenance Federal contract opportunity
- Solicitation number
- W912DS18B0023
View the file
Other files for this federal contract opportunity
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2
DOOR LEAF IN OPEN POSITION
1 2
DOOR LEAF IN
CLOSED POSITION
1 2
DOOR LEAF IN OPEN POSITION
DOOR LEAF IN
CLOSED POSITION
3"
SEE DETAIL
2'-0"
12'-5"
SEE DETAIL
2'
2'
1/2"X3" STEEL BAR
5/8" PLYWOOD(FILLER)
1/4"FILLER
9'-10"
9"
9"
5'-8" 5'-8"
SQ. TUBE 3"X3"X5/16"(TYP.)
6"
SEE DETAIL
3 4
11'-4"
1/4"Pb
1/2"X3" STEEL BAR
5/8" PLYWOOD FILLER
1/4Pb
1/4" FILLER MAT.
DOOR ASTRAGAL
16ga STEEL PLATE FILLED w/1/8" Pb
(ATTACHED TO EACH DOOR LEAF)
6"
16ga STEEL PLATE COVER
16ga STEEL PLATE COVER
4"Ø SCHED.
120 STEEL PIPE
1 2
1'
4'-6"
RECT.TUBE 4"X3"X5/16"
SQ.TUBE 3"X3"X5/16"
3"
RECT.TUBE 4"X3"X5/16"
SQ.TUBE
3"X3"X5/16"
SQ.TUBE 3"X3"X5/16"
L4"X3"X3/8"
3"
SQ.TUBE3"X3"X5/16"
L4"X3"X3/8"
SQ.TUBE
3"X3"X5/16"
1/2"X3"PL.
HORIZ. STEEL BAR(TYP.)
1/2"X3"PL.
HORIZ. STEEL BAR(TYP.)
4'-6"
1'
4"Ø SCHED 120 STEEL PIPE
4'-10"
1997 Rte 17m
Goshen, NY 10925
21'-7"
7'-10" 5'-11" 7'-10"
1"
2'-7" 2'-7" 2'-7"
2'-11
" 2'-11
2'-7" 2'-7"
10" 10" 10" 4' 10" 4'
OPEN BRACKET
LOCK JOINT BRACKETLOCK JOINT BRACKET
OPEN BRACKET (TYP)
2'-7"
1"
TOTAL TRACK LENGTH
DOOR HANGER
RECT. TUBE
4"X3"X 5/16"
9'-10"
3"
6" 6" 6"6"
L 4"X3"X3/8"
RECT. TUBE
3"X3"X5/16"
(TYP.)
5 8
5 8
21'-7"
DOOR GUIDE (TYP.)
RECT. TUBE
3"X3"X5/16"
(TYP.)
6" 6"
STEEL BAR
3"X1/2" (TYP.)
5'-8" 5'-8"
STEEL BAR
3"X1/2" (TYP.)
LINE OF WALL OPENING
LOCK JOINT BRACKET
DOOR HANGER
RECT. STEEL TUBE
4"x3"x5/16"
TOP TRACK
DOOR GUIDE
FLOOR CHANEL
TOP OF CONCRETE FLOOR
3 8
3"
16ga.PL.COVER 16ga.PL.COVER
SQ.TUBE
3"X3"X5/16"
2'-7"
7'-10"
21'-7"
2'-7"
1"
2'-7"
7'-10"
4' 10"4'10"10"10"
2'-7"
2'-11
"2'-11
2'-7"
5'-11"
LINE OF WALL OPENING
RECT. TUBE
4"X3"X 5/16"
DOOR HANGER
5'-8" 5'-8"
1"
TOTAL TRACK LENGTH
2'-7"
1'-6"
12'-7
1'-7
9'-6
RELEASE PIN
C.L. OPERATOR
JF
HS HS
JF
HS
JF
HS
JF
PWF
EPWT
AS
CA
192 LOCKER POSITIONS
MS06BMS35
RR05
E L S
E L S
E L S
UP
15 15
F
F185
F
185 F
185 F
F
185185
FF
F 185
F 185
F
JF
HSHS
JF
HS
JF
HS
JF
PWF
EP WT
AS
CA
EP
JF
HS
CA
AS
WT
PW
AS
JF
JF
JF
HS
WT
WT
CA
CTK.
ELEC./
400 HZ.
HANGAR BAY
ADMIN.
J
H
G
F
E
D
C
B
C.7
D.3
4 5 6 7 8 9 10 119.4 9.87.2 7.8
CONTINUOUSLY FROM DEVICES TO DEVICES WITHOUT ANY SPLICES. DRAIN
WIRE SHALL BE CONNECTED TOGETHER AND INSULATED INSIDE THE
JUNCTION BOX. DRAIN WIRE MUST NOT BE CONNECTED TO BUILDING
1. REFER TO DRAWING NO. E-001 FOR SYMBOL LIST AND ABBREVIATIONS.
2. REFER TO DRAWING NO. EY-601 FOR BUILDING FIRE ALARM RISER DIAGRAM.
6. ADDRESSABLE LOOP AND APPLIANCE NOTIFICATION WIRINGS SHALL BE RUN
NOTES:
GROUNDING.
3. REFER TO DRAWING NO. EY-602 FOR BUILDING FOAM SYSTEM RISER DIAGRAM.
4. REFER TO DRAWING NO. EY-102 FOR MOUNTING HEIGHT OF FIRE ALARM PULL
STATION, HORN AND STROBE DEVICES.
5. REFER TO DRAWING NO. EY-102 FOR MOUNTING HEIGHT OF FOAM SYSTEM
MANUAL ACTIVATION STATION AND COMBINATION HORN/BLUE BEACON STROBE
LIGHT DEVICES.
UP
F
185 185
F of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N E
W
Y O
R K
N
R K
D
IS
T R
IC
T
C
R P
S
F
N
G
IN
E E
R S
U .S
A R
M
G
IN
E
R
D
IV
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
IR
A
R
B
S E
N E
W
J E
R S
E Y
C
H
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
SCALE: 1/8" = 1'-0"
4 8 160
SCALE:
1/8"=1'-0"
AREA A GROUND FLOOR FIRE ALARM PLAN
EY101
NN
TRUE NORTH PLAN NORTH
EY-101
A R
G
O U
L
O
A
A N
E L E
C T
R
IC
T E
D
R C
C
A R
C
K P
K
R C
C
E Y
G F
A .D
W G
KEY PLAN
AREA C
AREA B AREA A
AREA D
AREA F
AREA E
JF
HS HS
JF
HS
JF
HS
JF
PWF
EPWT
AS
CA
192 LOCKER POSITIONS
MS06BMS35
RR05
E L S
E L S
E L S
UP
HEF
TS
TAMPER SWITCH FOR
HIGH EXPANSION FOAM
GENERATOR - LOCATED AT
PLATFORM ABOVE (TYPICAL)
M
HEF
HEF
HEF HEF
M
HEF
M
HEF
HEF
M HEF
HEF
HEF M
HEF HEF
M
M
HEF HEF
HEF
M
HEF
M
HEF HEF
JF
HSHS
JF
HS
JF
HS
JF
PWF
EP WT
AS
CA
EP
JF
HS
CA
AS
WT
PW
AS
JF
JF
JF
HS
WT
WT
CA
M
HEF
HEF
TS
TS
TS
TS
TS
TS
TS
TS
TS
TS TS
TS
ALARM ONLY
SET AT 40°F FOR
TS
ALARM ONLY
SET AT 40°F FOR
TS
ALARM ONLY
SET AT 40°F FOR
TS
ALARM ONLY
SET AT 40°F FOR
(TYP. FOR 4)
AT THE CATWALK
SENSOR - MOUNTED
TEMPERATURE
J
H
G
F
E
D
C
B
C.7
D.3
4 5 6 7 8 9 10 119.4 9.87.2 7.8
CONTINUOUSLY FROM DEVICES TO DEVICES WITHOUT ANY SPLICES. DRAIN
WIRE SHALL BE CONNECTED TOGETHER AND INSULATED INSIDE THE
JUNCTION BOX. DRAIN WIRE MUST NOT BE CONNECTED TO BUILDING
1. REFER TO DRAWING NO. E-001 FOR SYMBOL LIST AND ABBREVIATIONS.
2. REFER TO DRAWING NO. EY-601 FOR BUILDING FIRE ALARM RISER DIAGRAM.
6. ADDRESSABLE LOOP AND APPLIANCE NOTIFICATION WIRINGS SHALL BE RUN
NOTES:
GROUNDING.
3. REFER TO DRAWING NO. EY-602 FOR BUILDING FOAM SYSTEM RISER DIAGRAM.
4. REFER TO DRAWING NO. EY-102 FOR MOUNTING HEIGHT OF FIRE ALARM PULL
STATION, HORN AND STROBE DEVICES.
5. REFER TO DRAWING NO. EY-102 FOR MOUNTING HEIGHT OF FOAM SYSTEM
MANUAL ACTIVATION STATION AND COMBINATION HORN/BLUE BEACON STROBE
LIGHT DEVICES.
UP
M
HEF
of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
SCALE: 1/8" = 1'-0"
4 8 160
SCALE:
AREA A GROUND FLOOR H. E. FOAM SYSTEN PLAN
EY101
NN
TRUE NORTH PLAN NORTH
EY-101A
A R
O U
O
E
F O
S
T
A N
E L E
C T
R
IC
T E
D
R C
C
A R
C
K P
K
R C
C
E Y
G F
A .D
W G
KEY PLAN
AREA C
AREA B AREA A
AREA D
AREA F
CORROSION CONTROL/
COMPOSITE SHOP
PAINT BOOTH
WASH
STOR.
MEDIA BLASTER
HAZ MAT
COMM.
ADMIN.
CTK.
OVEN
CLEAN ROOM
FREEZER
SHEET METAL SHOP
STAIR
UP
159163
110110
F
F
F
F
F
TS WF
12" ALARM BELL
EP
BOOTH TYP. FOR 2
SHUT-DOWN FOR PAINT
EMERGENCY POWER
EP
WF
WF
WF
BOOTH
FOR PAINT
#3
#2
#1
J
H
G
F
E
D
C
B
C.7
D.3
1 2 3 3.3
STATION, HORN AND STROBE DEVICES.
CONTINUOUSLY FROM DEVICES TO DEVICES WITHOUT ANY SPLICES. DRAIN
WIRE SHALL BE CONNECTED TOGETHER AND INSULATED INSIDE THE
JUNCTION BOX. DRAIN WIRE MUST NOT BE CONNECTED TO BUILDING
1. REFER TO DRAWING NO. E-001 FOR SYMBOL LIST AND ABBREVIATIONS.
2. REFER TO DRAWING NO. E-002 FOR GENERAL NOTES.
3. REFER TO DRAWING NO. EY-601 FOR BUILDING FIRE ALARM RISER DIAGRAM.
4. REFER TO THIS DRAWING FOR MOUNTING HEIGHT OF FIRE ALARM PULL
5. ADDRESSABLE LOOP AND APPLIANCE NOTIFICATION WIRINGS SHALL BE RUN
NOTES:
GROUNDING.
HEF
COMBINATION
HORN/BLUE BEACON
STROBE LIGHT
M
MANUAL ACTIVATION
STATION
HEF
FINISHED
FLOOR
F
F
PULL STATION
FIRE ALARM
FIRE ALARM
HORN/STROBE
F
F
FLOOR
FINISHED
F
F
FIRE ALARM
STROBE
FIRE ALARM
HORN
of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
SCALE: 1/8" = 1'-0"
4 8 160
SCALE:
AREA B GROUND FLOOR FIRE ALARM PLAN
EY102
NN
TRUE NORTH PLAN NORTH
EY-102
E L E
C T
R
IC
T E
D
R C
C
A R
C
K P
K
R C
C
E Y
G F
B .D
W G
KEY PLAN
AREA C
AREA B AREA A
AREA D
AREA F
AREA E
A R
O U
O
A
D
SCALE:
N.T.S.
TYPICAL MOUNTING HEIGHT OF FOAM SYSTEM MANUAL ACTIVATION
STATION AND COMBINATION HORN/BLUE BEACON STROBE LIGHT
EY102 SCALE:
N.T.S.
TYPICAL MOUNTING HEIGHT OF FIRE ALARM PULL
STATION, HORN/STROBE, STROBE AND HORN DEVICES.
EY102
GROUP D, T1
CLASS 1 DIV. 1,
HAZARDOUS LOCATION
GROUP D, T1
CLASS 1 DIV. 1,
HAZARDOUS LOCATION
F
A
V
U N
T
IN
T A
IL
30110
75 75
HEF
F F
WF
CANOPY
FOR DRY SRINKLER AT
TS
PS
#5
0"
0"
R U
B
B
T
R U
B B
T
R U
B
B
T
MP10
MP09
OFFICE
ADMIN.
CTK.
MACHINE SHOP
WELDING SHOP
BOTTLE
STOR.
BOTTLE
STOR.
MP08
MP11
MP26
MS02
MP07
M S
MS30
MS34
M S
M S
MS32
MS15
MS08
MS06A
MS32
MS07
MS32 MS32 MS32 MS32MS40
MS22 MS23 MS21 MS24 MS25 MS30
MS32 MS32 MS32
MS14
MS30
MS10 MS11
MS41
MS40MS40MS40
MS30
MS19
MS17 MS16
MS06BMS35
MS01
MS33
MS32
MS29
MP26
MP20
MP06
MP12
MP13
MP21
MP16
MP19
MP17
MS37
MS37
MS37
MS37
MS37
MS37
MS37
MS37MS37 MS37
MS37
MS37
MS26
MP26
MP04
MP01
MP18
MP04
MP01
MP18
MP04
MP01
MP18
MP04
MP01
MP18
MP04
MP01
MP18
MP04
MP01
MP18
0"
0"
F F
F
FLUSH MOUNTED
FIRE ALARM/HIGH
EXPANSION FOAM
REMOTE ALARM
AND VISUAL GRAPHIC
ANNUNCIATOR
WF
WF
WF
#8
#7
#6
0""
0"
0"
0"
0"
0" 0"
192 LOCKER POSITIONS
23 LOCKERS
MEN
VENDING
LOBBY
OFFICE
JAN.
WOMEN
CONF.
ADMIN.
VEST.
LOCKER ROOM
MS30
BREAK ROOM
0""
0"
0"
0"
0"
0" 0"
OIL
ANALYSIS
LAB
X-RAY
VAULT
NDI
SHOP
PROCESS'G
VIEWING
OFFICE
CTK/EQUIP.
VEST.
VEST.
ND2
ND1
BEYOND.
HANGER
MONORAIL
BEYOND
MONORAIL
T
S T
L
W x
27'-7 7/8")
(T/STL.
W12x35
120 STL. PIPE.
4" DIA. SCHED
ELEC.
COMM.
M
L
K.7
K
J.9
J.1
1 2 3 4 5 63.3
7 8 9 10 119.4 9.87.2 7.8
M
L.3
L
K.7
K.6
K.5
K
J.8
3. REFER TO DRAWING NO. EY-102 FOR MOUNTING HEIGHT OF FIRE ALARM PULL
STATION, HORNS AND STROBES DEVICES.
CONTINUOUSLY FROM DEVICES TO DEVICES WITHOUT ANY SPLICES. DRAIN
1. REFER TO DRAWING NO. E-001 FOR SYMBOL LIST AND ABBREVIATIONS.
2. REFER TO DRAWING NO. EY-601 FOR BUILDING FIRE ALARM RISER DIAGRAM.
4. ADDRESSABLE LOOP AND APPLIANCE NOTIFICATION WIRINGS SHALL BE RUN
WIRE SHALL BE CONNECTED TOGETHER AND INSULATED INSIDE THE
JUNCTION BOX. DRAIN WIRE MUST NOT BE CONNECTED TO BUILDING
GROUNDING.
NOTES:
of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
T E
D
R C
C
A R
C
K P
K
R C
C
E Y
G F
C .D
W G
SCALE:
AREA D GROUND FLOOR FIRE ALARM PLAN
EY103
N N
PLAN NORTHTRUE NORTH
SCALE:
AREA C GROUND FLOOR FIRE ALARM PLAN
EY103
PLAN NORTHTRUE NORTH
N N
KEY PLAN
AREA C
AREA B AREA A
AREA D
AREA F
AREA E
0 1684
SCALE: 1/8" = 1'-0"
EY-103
A R
O U
O
A
A N
S
E L E
C T
R
IC
A L
GROUP D, T1
CLASS 1 DIV. 2,
GROUP D, T1
CLASS 1 DIV. 2,
MECH.
BEARING
CLEANING
ROOM
FIRE PROTECTION
REPAIR &
RECLAMATION SHOP
ADMIN.
ADMIN.
CTK.
ELECT. COMM.
GENERATOR
WHEEL & TIRE SHOP
W T
W T
W T
W T
W T
WT16
WT23
WT23
WT10
W T
W T
WT24
WT22
WT22
WT22
WT06
WT05 WT07
WT04
WT26
WT17
W
T
WT17 WT17 WT17 WT17 WT17
WT17WT17WT17WT17WT17
WT24
WT17WT17WT17WT17
WT17WT17WT17WT17WT17
WT12
WT01
WT13
RR07
RR06
RR02
RR03
RR04
RR28
RR09
RR17
RR09
RR11
RR11
RR23
RR27
RR17
RR12
RR17
RR10
RR17
RR17
RR20
RR17RR17
RR12 RR23
RR20
RR01
RR13
RR05
R R
WT14
W T
WT02
COOLING
UNIT
RR02
132 133
110 110
75 75
F
F F
F
F
WF
WF
TIRE SHOP
#9
TEST STAND
ADMIN.
CTK.
COMM.
LOX CART
REPAIR
PNEUDRAULICS SHOP
ELEN SHOP
DIFM
SPIN RIVETER HAZ MAT
NI-CAD
BATTERY
LEAD ACID
BATTERY
OXYGEN
CO2
PN15PN16
PN05
PN03
P N
9 PN21
P N
9 PN21
P N
9 PN21
P N
9 PN21
P N
PN21
PN01
PN13
PN04
PN11
E L S
ELS05
E L S
ELS27
E L S
E L S
ELS12
ELS12
ELS12
ELS12
ELS12
ELS12
ELS12ELS12ELS12
E L S
E L S
E L S
E L S
E L S
E L S
E L S
E L S
E L S
BS21 BS21
BS14
BS14
BS08
(2)BS14
BS21 BS21
PN19 PN19PN19
PN20
PN20
PN20
PN20
ELS
PN06
PN17
ELS
ELS ELS
ELS ELS ELS
145 143
153154
110 110
XP
XP
XP
F
F
F
F
F
F
XP
F
FXP
WF
WF
WF
#11
11 12 13 1412.6 13.311.4 M
L.3
L
K.7
K.6
K.5
K
J.8
J
H.6
H
G
12 13 1412.6 13.311.4
F.3
F
E
D.1
D
C.1
C
B
A
NOTES:
GROUNDING.
4. ADDRESSABLE LOOP AND APPLIANCE NOTIFICATION WIRINGS SHALL BE RUN
3. REFER TO DRAWING NO. EY-102 FOR MOUNTING HEIGHT OF FIRE ALARM PULL
2. REFER TO DRAWING NO. EY-601 FOR BUILDING FIRE ALARM RISER DIAGRAM.
1. REFER TO DRAWING NO. E-001 FOR SYMBOL LIST AND ABBREVIATIONS.
JUNCTION BOX. DRAIN WIRE MUST NOT BE CONNECTED TO BUILDING
WIRE SHALL BE CONNECTED TOGETHER AND INSULATED INSIDE THE
CONTINUOUSLY FROM DEVICES TO DEVICES WITHOUT ANY SPLICES. DRAIN
STATION, HORNS AND STROBES DEVICES.
of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
SCALE: 1/8" = 1'-0"
4 8 160
SCALE:
AREA E GROUND FLOOR FIRE ALARM PLAN
EY104
NN
TRUE NORTH PLAN NORTH
EY-104
E L E
C T
R
IC
T E
D
R C
C
A R
C
K P
K
R C
C
E Y
G F
E .D
W G
SCALE:
AREA F GROUND FLOOR FIRE ALARM PLAN
EY104
TRUE NORTH PLAN NORTH
NN
KEY PLAN
AREA C
AREA B AREA A
AREA D
AREA F
AREA E
A R
O U
O
A
A N
S
GROUP D, T1
CLASS 1 DIV. 1,
HAZARDOUS LOCATION
GROUP D, T1
CLASS 1 DIV. 2,
HAZARDOUS LOCATION
GROUP D, T1
CLASS 1 DIV. 2,
HAZARDOUS LOCATION
GROUP D, T1
CLASS 1 DIV. 2,
HAZARDOUS LOCATION
GROUP D, T1
CLASS 1 DIV. 2,
HAZARDOUS LOCATION
GROUP D, T1
CLASS 1 DIV. 2,
HAZARDOUS LOCATION
NORTH
MEZZANINE
WEST
MEZZ.
EAST
MEZZ.HANGAR BAY
UP
201 203114
M
L
K
J
H
G
F
E
D
C
B
M
L
K
J
H
G
F
E
D
C
B
1 2 3 4 5 6 7 8 9 10 11 12 13 14
A A
C.1
D.1
J.8
K.6
L.3
K.5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 13.33.2 12.6
K.7
K.7
11.4 10.8
F.3
H.6
4.23.7
C.7
D.3
9.4 9.8
J.9
7.2 7.8 11.42.6
J.1
UP
75757575
F
F
F
F
F
D
D
D
D
D
D
D
D
D
D D D
AHU-10-1
MAU-9-1
AHU-9-1
ACU-9-1
AHU-8-1
AHU-7-1
AHU-6-1
AHU-5-1
AHU-4-1
ACU-1-1AHU-1-1
M
L
K
J
H
G
F
E
D
C
B
M
L
K
J
H
G
F
E
D
C
B
1 2 3 4 5 6 7 8 9 10 11 12 13 14
A A
C.1
D.1
J.8
K.6
L.3
K.5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 13.33.2 12.6
K.7
K.7
11.4 10.8
F.3
H.6
4.23.7
C.7
D.3
9.4 9.8
J.9
7.2 7.8 11.42.6
J.1
EY-105
Z Z
A N
V
A
A N
E L E
C T
R
IC
A L
T
C
A R
C
K P
K
R C
C
E Y
M F
A .D
TRUE NORTH PLAN NORTH
N N
SCALE: 1/16" = 1'-0"
80 16 32
SCALE:
1/16"=1'-0"
MEZZANINE LEVEL FIRE ALARM PLAN
EY105
of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
F F F FF
WEST MEZZANINE NORTH MEZZANINE EAST MEZZANINE
MACHINE SHOP ADMIN WELDING SHOP
F F
AREA C
AREA B
F F F F F
CORROSION CONTROL / COMPOSITE SHOP CLEAN ROOM ADMIN. SHEET METAL SHOP
MEDIA
BLASTER
HAZ.
MAT.
AREA A
HANGAR BAY ADMIN.
F F F F F F F F F F
ELEC.
400HZ PNEUDRAULICS SHOP ADMIN. ELEN SHOP
F F
HAZ.
MAT. BATTERY
NI.-CAD.
F
XP XP
F
LEAD ACID
BATTERY CO2
AREA F
F F F F F F
AREA E
PROTECTION
FIRE
MECH. ELEC. GENERATOR WHEEL & TIRE SHOP ADMIN. ADMIN. REPAIR & RECLAMATION SHOP
F
15 15
F F
AREA D
NDI SHOP BREAK ROOM MEN LOCKER ROOM LOBBY CONF. ADMIN. WOMEN
LOCKER ROOM
OIL
ANALYSIS
ELEC.
CONTROL PANEL
SYSTEM
FIRE ALARM
MAIN
RM (168) RM (169) RM (171)
RM (159) RM (161) RM (158) RM (156) RM (165) RM (163)
RM (114) RM (116) RM(117) RM (141) RM (148) RM (147) RM (153)RM (143) RM (150) RM (151)
RM (130) RM (131) RM (132) RM (134) RM (135) RM (138)RM (140) RM (139)
RM (118) RM (112) RM (111) RM (102) RM (106)RM (103) RM (121)
RM (107) RM (123)
(201) (202) (203)
75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75
30 110 110 30 30 110 110 15
75 75 15 75 75 75 110 110 110 15 15 30 75 75 110
30 30 30 110 75
RM (110)
75 15 15 15 110 30 15 3075 75 75 30 110 30 30 110 15 110
30 110 75 110 110 1101511011011011015157575
151518518518518518518575185185185185
J
F
(155)
STAIR
F
XP
NOTES:
PANEL
MONACO
1#8GRD - 3/4"C
TO BUILDING
STEEL COLUMN
TVSS
C C C C C C C C C C C C C C
C
A A A
A A
C C C C C C C C C C C C C C C C CC C C C C
C
C
C
A A A A A A A A A A A A A A A A A A A A
C C C C C C C C C C C C C C C
C
C
A A A A
A
A A A A A A A A A
A A
C C C C C C C C C
CC
A A A
A CCCC
C C C C C C C C C C C C C C C C C C
C
C
C
A A
A
A A A A A A A A A A A A A A
AA
C
C
A
A
A
RG-1
IN 3/4"C
COAXIAL CABLE
REMOTE GRAPHIC
ANNUNCIATOR
1"C
A
C
NO. 3
NOTE
SEE
A
D D D D D D D D D D D
A
A A A A A A A A A A A
AHU-8-1 ACU-9-1 AHU-9-1 MAU-9-1 AHU-1-1 ACU-1-1 AHU-4-1 AHU-5-1 AHU-6-1 AHU-7-1
X
P
XX13
DRY-PIPE SPRINKLERS
HI-LO PRESSURE SWITCHES -
TEMPERATURE MONITORING SYSTEM
VALVE SUPERVISORY SWITCHES -
WATER SUPPLY ENTRANCE
TROUBLE CONDITION
CIRCUIT FAULT
LOW BATTERY VOLTAGE
TROUBLE CONDITIONS
CONTROL COMPONENT COMMON
AC POWER FAILURE
SUPERVISED COMPONENT FAILURE18
X
X X
X
X
X
X
X
X
X
X
X
X
FIRE ALARMS
MANUAL FIRE ALARM STATIONS
FIXED TEMP TYPE HEAT DETECTORS
PHOTOELECTRIC-TYPE
SPRINKLER SYSTEMS IN ALL AREAS
SPRINKLER SYSTEM - CANOPY
WATER FLOW SWITCHES - WET-PIPE
WATER FLOW SWITCHES WET-PIPE
IN-DUCT SMOKE DETECTORS
AREAS EXCEPT HANGAR AREA
VALVE SUPERVISORY SWITCH -
OR DRY-PIPE SPRINKLERS IN ALL
VALVE SUPERVISORY SWITCH - WET
SUPERVISORY SIGNALS
SPRINKLER SYSTEM IN HANGAR
SPRINKLERS IN HANGAR AREA
X X
D
X
X
SYSTEM INPUTS
CBA
X
X
X
X
HGE F KJI
X
X
X
X
X
X X
X
ML
X
N
X
X
SMOKE DETECTORS
X XX
PRESSURE SWITCH PRE-ACTION
O
X
EXCEPT HANGAR AREA
AREA
X X
X
H A
N G
E A
SYSTEM OUTPUTS
F O
A M
W A
T
IS
C H
A R
G E
IN
B L
U
R O
B E
B E
A C
O N
F O
S
T
IG
N A
L
A U
D
IO
V
IS
U
N A
L
F A
C
IL
IT
V
A C
U A
T
IO
C
IR
C U
L A
T
N S
S H
P P
L Y
C O
M M
P E
R V
IS
O
N A
L
C O
M M
R
IN
K L
T
O W
C O
M M
A R
M
C O
M M
O U
B
N A
L
A U
D
IO
V
IS
U
A R
M
IN
D
IC
A T
IO
V
IC
E
S
IG
N
M P
H O
U S
E
T R
A N
S
A R
T
T R
O U
B L E
IN
D
IC
A T
IO
N
A U
D
IO
V
IS
U
M M
O N
IN
D
IC
A T
Z
D
IV
ID
U A
L
A U
D
IO
V
IS
U
O U
B L E
S P
R
IN
K L
L V
E S
O P
E
A C
T
IO
N
IN
D
IC
A T
D
IV
ID
U A
L
A U
D
IO
V
IS
U
A R
M
TRANSMIT SIGNALS TO
FIRE DEPARTMENT
ANNUNCIATION AT
LOCAL PANELS
FIRE SUPPRESSION
SYSTEM FUNCTIONS
AUXILIARY
FUNCTIONS
EVACUATION
SIGNALS
P O
W
U T
D O
L
E L E
C
P O
W E
N G
E A
E X
C E
X
E R
L T
G
D E
V
IT
D R
E S
S
D E
V
IT
D R
E S
S
O P
V
A M
S Y S
T
L E
A
L V
E
J
FOR CONNECTIONS.
REFER TO DWG. NO. E-601
FUSED CUT-OUT BOX -
TO 20A, 1P, 120V FUSE IN
2#12 + 1#12GRD - 3/4"C
LOCATION
BASE FOR EXACT
WITH MCGUIRE AIR FORCE
ANTENNA - COORDINATE
"MONACO" RADIO
GROUNDING SYSTEM
TO BUILDING
1#8GRD - 3/4"C
TO DWG. NO. EY-602)
CONTROL PANEL (REFER
1 1/4"C TO FOAM SYSTEM
(SEE NOTE NO. 11)
LOBBY AREA 'D'
LOCATED IN THE
EXPANSION FOAM
FIRE ALARM/HIGH
STEEL COLUMN
TO NEAREST BLDG.
1#8GRD - 3/4"C
TWISTED) IN 3/4"C
4 PRS. #18 (SHIELDED
REFER TO DWG. EY-602.
PUMP START SIGNAL -
PANEL FOR REMOTE FIRE
TO FOAM SYSTEM CONTROL
CONDUIT RUN (SEE NOTE #12)
DWG. NO. C-107A FOR COMPLETE
REMOTE FIRE PUMP START (REFER TO
5#12 - 1"C TO RISER POLE FOR
FOR ROUTING OF CONDUIT TO THE EXISTING PUMP HOUSE FOR FIRE PUMP START SIGNAL.
CONTROL PANEL IN THE PUMP HOUSE BLDG. NO. 3102. REFER TO CIVIL DRAWING NO. C-107A
COORDINATE WITH MCGUIRE AIR FORCE BASE FOR LOCATION OF FIRE PUMP "REMOTE START"
FOR MAIN FIRE ALARM CONTROL PANEL AND 2#12 FOR FOAM SYSTEM CONTROL PANEL).
12. CONNECT TO SPARE "START" TERMINALS IN THE REMOTE PUMP START CONTROL PANEL (2#12
IN "BLUE LED" LAMPS.
BE INDICATED BY "RED LED" LAMPS AND HIGH EXPANSION FOAM VISUAL INDICATIONS SHALL BE
ALARM SYSTEM AND HIGH EXPANSION FOAM SYSTEM. ALL FIRE ALARM VISUAL INDICATIONS SHALL
REMOTE ALARM AND VISUAL GRAPHIC ANNUNCIATOR SHALL BE COMMON FOR BOTH BUILDING FIRE 11.
FOAM SYSTEM CONTROL PANEL.
INTERCONNECTIONS SHALL BE PROVIDED BETWEEN BUILDING FIRE ALARM CONTROL PANEL AND 10.
MODULES.
ALL TAMPER SWITCHES AND WATER FLOW SWITCHES SHALL BE PROVIDED WITH SWITCH CONTROL 9.
C - 2#14
B - 1 PAIR #18 - SHIELDED TWISTED PAIR
A - 1 PAIR #18 - SHIELDED TWISTED PAIR
WIRE SIZE LEGEND: 8.
MOUNTED 48" AFF UNLESS OTHERWISE NOTED.
ALL MANUAL PULL STATIONS SHALL BE DOUBLE ACTION, ADDRESSABLE TYPE AND TO BE 7.
ALL HORNS AND STROBES SHALL BE MOUNTED 6'-8" AFF UNLESS OTHERWISE NOTED. 6.
CLEAN UP OF THE BUILDING IS DONE.
ALL DETECTORS AND NOTIFICATION DEVICES SHALL NOT BE INSTALLED UNTIL THE CONSTRUCTION 5.
WATER FLOW SWITCHES.
REFER TO SPRINKLER FIRE PROTECTION DRAWINGS FOR LOCATION OF ALL TAMPER SWITCHES AND 4.
RING SUPPRESSION (2000 VOLTS, 67 AMPERES, 180 DEGREES) OF LESS THAN 50V.
TERMINAL. THE TVSS DEVICE SHALL PROVIDE NOMINAL SINE WAVE TRACKING, WITH CATEGORY A1
INSTALL TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) AT THE INCOMING 120V POWER 3.
SHALL BE 3/4" DIAMETER.
ALL WIRING SHALL BE RUN IN RIGID STEEL CONDUIT, MINIMUM SIZE OF CONDUIT TO BE USED 2.
FIRE ALARM SYSTEM CONTROL PANEL SHALL BE ADDRESSABLE TYPE CONTROL PANEL. 1.
RM (133)
COMM.
A
TVSS
NO. 3
SEE NOTE TVSS
D
AHU-10-1
IM
TS
IM
TS
IM
IM
IM
IM
IM IM
IM
IM
IM
IM
TS
IM
IM
IM
IM
TS
IM
IM
IM
NDI-SHOP
OFFICES/LOBBY
NORTH MEZZ.
WELDING SHOP PAINT BOOTH
CORR/COMP.
WEST MEZZ.
DRY SYSTEM
WEST CANOPY
SHEET METAL
SHOP & STAIR
TIRE SHOP
ELLEN SHOP
PNEUDRAULICS
SHOP
EAST MEZZ.
RECLAMATION SHOP
EAST CANOPY
IM
TS
PIV
ZONE #1
RISER #1
ZONE #2
RISER #2
(HANGAR AREA)
ZONE #3
RISER #3
A
A
A
A
A A
A
A
A A
A
A
A
A
A
A
A
A
A
A
RM (122)
COMM.
C
A
RM (152)
OXYGEN LOX CART
RM (154) RM (149)
COMM.
F
A A
F
A
F
XP
A
F
XP
X
X
X
XX
A A A
AREA
DISCHARGE STATION IN HANGAR
HIGH EXPANSION FOAM MANUAL
X
FOR CONNECTIONS.
REFER TO DWG. NO. E-601
FUSED CUT-OUT BOX -
TO 20A, 1P, 120V FUSE IN
2#12 + 1#12GRD - 3/4"C
X
X
OS&Y VALVE
OS&Y VALVE
OS&Y VALVE
TS
DRY PIPE
VALVE
RM. 130
PROTECTION ROOM -
RISER NO. 1 FIRE
WF
WF
WF
WF
WF
#8
#7
#6
#5
PS
WF
WF
#1
#2
WF
WF
#3
#4
WF
RM. 130
PROTECTION ROOM -
RISER NO. 2 FIRE
WF
WF
WF
#9
#10
#11
WF
WF
#13
#12
ROOM - RM. 130
FIRE PROTECTION
WF
FLOOR PLAN DRAWING EY-101A
LOCATED AT THE CATWALK - REFER TO
TO TEMPERATURE MONITORING SYSTEM
of
S u b m it t e d b y
D e s ig n
D r a w n
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w
C h e c k
R e v
D a t e
D r a w in g f o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F a m e
P lo t t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
EY-601
E L E
C T
R
IC
T E
D
R C
C
A R
C
K P
K
R C
C
E Y .D
W G
F
A
IA
G R
D
EY601
SCALE: NONE
BUILDING FIRE ALARM SYSTEM RISER DIAGRAM
EY601
2 BUILDING FIRE DETECTION AND ALARM SYSTEM FUNCTIONAL MATRIX
SCALE: NONE
F U
N C
T
IO
N
T
IX
H E
D U
L
PANEL
CONTROL
SYSTEM
FOAM
1#8GRD - 3/4"C
TO NEAREST BLDG.
STEEL COLUMN
WFSV
SOLENOID VALVE
HIGH EXPANSION
FOAM DELUGE
TS
TS
M MM M M
HEF HEF HEF HEF HEF
HEF HEF HEF HEF HEF
SEE
NOTE
COL. J/7COL. J/4COL. H/4COL. C.7/4COL. B/4
COL. E-F/4B
B
C C C C
C
COL. D/11 COL. A/11
M
HEF
B
HEF
C
M
COL. J/9.6
MM
COL. F/11COL. G-H/11
MB
B
HEFHEFHEF
BB
C
HEFHEFHEF
CC
HEF
HEF
2. ALL WIRING SHALL BE RUN IN RIGID STEEL CONDUIT, MINIMUM SIZE OF CONDUIT
TO BE USED SHALL BE 3/4" DIAMETER.
3. INSTALL TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) AT THE INCOMING
120V POWER TERMINAL. THE TVSS DEVICE SHALL PROVIDE NOMINAL SINE WAVE
TRACKING, WITH CATEGORY A1 RING SUPPRESSION (2000 VOLTS, 67 AMPERES,
180 DEGREES) OF LESS THAN 50V.
4. REFER TO FIRE PROTECTION DRAWINGS FOR LOCATION OF ALL TAMPER
SWITCHES, FOAM DELUGE SOLENOID VALVE, AND PRESSURE SWITCH ALARM.
HEF
C
B
B B
SYSTEM
FOAM
START
FOAM
RED LETTERS
MANUAL FOAM DISCHARGE STATION
TAMPER COVER
DISTINCTIVE "YELLOW" SIGN
1. FOAM SYSTEM CONTROL PANEL SHALL BE ADDRESSABLE TYPE CONTROL PANEL.
6. ALL HORN/STROBE/BEACON SHALL BE MOUNTED 6'-8" AFF UNLESS OTHERWISE
NOTED.
7. ALL MANUAL FOAM DISCHARGE STATIONS SHALL BE DOUBLE-ACTION, ADDRESSABLE
TYPE AND TO BE MOUNTED 48" AFF UNLESS OTHERWISE NOTED.
5. ALL DETECTORS AND NOTIFICATION DEVICES SHALL NOT BE INSTALLED UNTIL THE
CONSTRUCTION CLEAN UP OF THE BUILDING IS DONE.
8. WIRE SIZE LEGEND:
9. ALL TAMPER SWITCHES SHALL BE PROVIDED WITH SWITCH CONTROL MODULES.
10. PROVIDE INTERCONNECTIONS BETWEEN BUILDING FIRE ALARM CONTROL PANEL AND FOAM
SYSTEM CONTROL PANEL (FSCP).
TVSS
11. REMOTE ALARM AND VISUAL GRAPHIC ANNUNCIATOR SHALL BE COMMON FOR BOTH
BUILDING FIRE ALARM SYSTEM AND HIGH EXPANSION FOAM SYSTEM. ALL FIRE ALARM
VISUAL INDICATIONS SHALL BE INDICATED BY "RED LED" LAMPS AND HIGH EXPANSION
FOAM VISUAL INDICATIONS SHALL BE IN "BLUE LED" LAMPS.
12. CONNECT 2#12 TO SPARE "START" TERMINALS IN THE REMOTE PUMP START CONTROL
PANEL. COORDINATE WITH MCGUIRE AIR FORCE BASE FOR LOCATION OF FIRE PUMP
"REMOTE START" CONTROL PANEL IN THE PUMP HOUSE BLDG. NO. 3102. REFER
(SEE NOTE NO. 11)
LOBBY AREA 'D'
LOCATED IN THE
FIRE ALARM/HIGH
EXPANSION FOAM
ANNUNCIATOR
REMOTE GRAPHIC
1"C
NO. 3
B - 1 PAIR #18 - SHIELDED TWISTED PAIR
A - 1 PAIR #18 - SHIELDED TWISTED PAIR
C - 2#14
NOTES:
P
H A
N G
E A
F O
A M
W A
T
C H
A R
G E
IN
B L
R O
B E
B E
A C
O N
F O
S
T
N A
L
C O
M M
P E
R V
IS
O
N A
L
C O
M M
R
IN
K L
T
O W
C O
M M
A R
M
C O
M M
O U
B
N A
L
A U
D
IO
V
IS
U
A R
M
IN
D
IC
A T
V
IC
E
S
IG
N
M P
H O
U S
E
T R
A N
S
A R
T
T R
O U
B L E
IN
D
IC
A T
IO
N
A U
D
IO
V
IS
U
M M
O N
IN
D
IC
A T
D
IV
ID
U A
L
A U
D
IO
V
IS
U
O U
B L E
S P
R
IN
K L
L V
E S
O P
E
A C
T
IO
N
IN
D
IC
A T
D
IV
ID
U A
L
A U
D
IO
V
IS
U
A R
M
TROUBLE CONDITIONS
X
X X
X
X
X
X
X
X
X
X
SUPERVISORY SIGNALS
DCBA HGE F KJI
X
X
ML N
TRANSMIT SIGNALS TO
FIRE DEPARTMENT
ANNUNCIATION AT
LOCAL PANELS
FIRE SUPPRESSION
SYSTEM FUNCTIONS
AUXILIARY
FUNCTIONS
EVACUATION
SIGNALS
P O
W
U T
D O
L
E L E
C
P O
W E
N G
E A
E X
C E
E R
L T
G
O
X X
D E
V
IT
D R
E S
S
D E
V
IT
D R
E S
S
TO CIVIL DRAWING NO. C-107A FOR ROUTING OF CONDUIT TO THE EXISTING PUMP
HOUSE FOR FIRE PUMP START SIGNAL.
O P
V
A M
S Y S
T
L E
A
L V
E
X
X X
X
X
X
X
X
X
X
X
X
X
X
SYSTEM INPUTS
FIRE ALARMS
SYSTEM OUTPUTS
AREA
EXCEPT HANGAR AREA
WATER FLOW SWITCHES PRE-ACTION
SMOKE DETECTORS
SPRINKLER SYSTEM IN HANGAR
IN-DUCT SMOKE DETECTORS
WATER FLOW SWITCHES WET-PIPE
WATER FLOW SWITCHES - WET-PIPE
SPRINKLER SYSTEM - CANOPY
SPRINKLER SYSTEMS IN ALL AREAS
PHOTOELECTRIC-TYPE
FIXED TEMP TYPE HEAT DETECTORS
MANUAL FIRE ALARM STATIONS
SPRINKLERS IN HANGAR AREA
VALVE SUPERVISORY SWITCH - WET
OR DRY-PIPE SPRINKLERS IN ALL
VALVE SUPERVISORY SWITCH -
AREAS EXCEPT HANGAR AREA
CONTROL COMPONENT COMMON
TROUBLE CONDITION
WATER SUPPLY ENTRANCE
VALVE SUPERVISORY SWITCHES -
TEMPERATURE MONITORING SYSTEM
HI-LO PRESSURE SWITCHES -
DRY-PIPE SPRINKLERS
SUPERVISED COMPONENT FAILURE
AC POWER FAILURE
LOW BATTERY VOLTAGE
CIRCUIT FAULT
EY-601 (SEE NOTE #12)
TO RISER DIAGRAM ON DWG.
FIRE PUMP START SIGNAL - REFER
TO JUNCTION BOX FOR REMOTE
FOR CONNECTIONS.
REFER TO DWG. NO. E-601
FUSED CUT-OUT BOX -
TO 20A, 1P, 120V FUSE IN
2#12 + 1#12GRD - 3/4"C
(SHIELDED TWISTED) IN 3/4"C
TRANSMITTER) 4 PRS. #18
TO MONACO PANEL (RADIO
RISER #3
AT HANGAR
SPRINKLER SYSTEM
FLOW SWITCH
NO. EY-601)
CONTROL PANEL (REFER TO DWG.
1 1/4"C TO BUILDING FIRE ALARM
H.E.F.RISER #4
VALVE
TEST HEADER
RISER #4
CONTROL VALVE
FOAM SYSTEM
A
IM
IM
IMCR
J
4#12 - 3/4"C
2#12 - 3/4"C
2#12 - 3/4"C
A
COL. H-G/6-7
TS
CM
COL. H-G/8-9
TS
CM
TS
CM
COL. H-G/5-6 COL. H-G/9.8
CM
TS
TS
CM
COL. E/5-6
TSTS
COL. F-E/7 COL. F-E/8
COL. E/9.8
TS
CM
CM CM
COL. C.7-C/5-6
TS
CM
CM
COL. D-C.7/7
TS
CM
COL. D-C.7/8
TS
TS
COL. C.7-C/9.8
CM
A
A
A
A
A
A
A
A
A
A
GATE VALVE TAMPER SWITCH
FOR HIGH EXPANSION FOAM
GENERATOR LOCATED AT THE
PLATFORM - TYPICAL FOR 12
A A
AREA
DISACHARGE STATION IN HANGAR
HIGH EXPANSION FOAM MANUAL
T R
A N
S
N
IL
D
IN
IT
IA
U T
D O
P P
C
IR
C U
L A
T
N S
T R
A N
S
N
IL
D
IN
IT
IA
C
IL
A C
U A
T
D
IO
V
IS
U
N A
L
VALVE ALARM PRESSURE SWITCH
HIGH EXPANSION FOAM DELUGE
9 X X XX X
13. SEQUENCING OF PUMP OPERATIONS AND ALL NECESSARY CONTROL WIRINGS
INSIDE THE PUMPHOUSE BUILDING NO. 3102 SHALL BE THE RESPONSIBILITY OF THE
GOVERNMENT.
IM
TS
OS&Y VALVE
IM
PS
SWITCH
PRESSURE
ALARM
IM
TS
VALVE
SHUT-OFF
WATER
PRESSURIZED
TS
VALVE
SHUT-OFF
SUPPLY
CONCENTRATE
FOAM
AA
IM
TS
VALVE
SHUT-OFF
WATER SUPPLY
PRESSURIZATION
TANK SHELL
A
#3
X X
BEARING
CLEANING
ROOM
FIRE PROTECTION
CTK/EQUIP.
F
TS
TS TS
WF
WF WF
TS
TS
TS
PS
SV
TS
F S
C P
F A
C P
PANEL
FOAM CONTROL
CONTROL PANEL
FIRE ALARM
TRANSMITTER PANEL
"MONACO" RADIO
J
(TYP. FOR 3)
TVSS
WIRES UP TO PUMP HOUSE NO. 3102.
DWG. NO. C-107A FOR ROUTING OF
FIRE PUMP START SIGNAL. REFER TO
5#12 IN 3/4"C TO RISER POLE FOR
TS
TS
FOAM PROPORTIONER
H.E.F. DELUGE VALVE AND
OS&Y VALVE
H.E. FOAM SYSTEM RISER H.E. FOAM TEST LINE
RISER NO. 2
OS&Y VALVE
RISER NO. 2
RISER NO. 1
RISER NO. 3
RISER NO. 1
OS&Y VALVE
RISER NO. 3
OS&Y VALVE
WATER SUPPLY SHUT-OFF VALVE
TANK SHELL PRESSURIZATION
VALVE
SUPPLY SHUT-OFF
FOAM CONCENTRATE
SHUT-OFF VALVE
PRESSURE WATER
WF
11 11.4
M
L of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
EY-602
E L E
C T
R
IC
T E
D
R C
C
A R
C
K P
K
R C
C
E Y .D
W G
H
P A
N S
S
T
G R
A M
EY602
SCALE: NONE
HIGH-EXPANSION FOAM RISER DIAGRAM
EY602
3 TAMPER COVER, AND SIGNAGE
SCALE: NONE
EY602
SCALE: NONE
WET-PIPE & LOW-LEVEL HIGH EXPANSION FOAM SYSTEM FUNCTIONAL MATRIX
SCALE: NONE
FIRE PROTECTION RM. 130 PART PLAN4
EY602
MANUAL FOAM DISCHARGE STATION,
F U
N C
T
IO
N
T
IX
H E
D U
L E
P A
A N
A
T A
IL
CLG CEILING
PENDENT CONCEALED SPRINKLER HEAD
SPRINKLER
ABOVE FINISHED FLOOR
ABBREVIATIONS
AFF
SPR
AFFF CONCENTRATE
NORMALLY CLOSED
NORMALLY OPEN
NOT IN CONTRACT
PRESSURE SWITCH
NOT TO SCALE
CONNECT
CEILING
DOWN
DRAWING
DIAMETER
BELOW FINISHED FLOOR
C
PS
DN
CLG
DIA
CONN
DWG
NC
NIC
NTS
BFF
NO
PLUMBING
ELECTRICAL
GALLON
EQUIPMENT
ROOM
POUNDS PER SQUARE INCH
MECHANICAL
HORSE POWER
GALLONS PER MINUTE
HP
MECH
ELEC
PLBG
PSI
EQUIP
GAL
GPM
RM
EL ELEVATION
DRY
FG-1
C
ALARM VALVE
CHECK VALVE
S m
SOLENOID VALVE
PIPE SLEEVE
O.S. & Y. GATE VALVE
PIPE DOWN
PRESSURE GAUGE
PIPE UP
STRAINER
FLOW SWITCH (FS)
FIRE DEPARTMENT CONNECTION (SIAMESE)
O.S. & Y. GATE VALVE W/TAMPER SWITCH
HYDRAULIC OPERATED VALVE
FOAM CONCENTRATE PIPING
HIGH EXPANSION FOAM GENERATOR
DRY SPRINKLER PIPE
FIRE PROTECTION LEGEND
WET SPRINKLER PIPING
UPRIGHT SPRINKLER HEAD
HYDRAULIC CONTROL LINE
DRY PENDENT SPRINKLER HEAD
HIGH PRESSURE FIRE WATER LINEHPFL
HIGH EXPANSION FOAM PIPEFOAM
0.15
0.40
0.40
EXTRA HAZARD
EXTRA HAZARD
0.15
0.15
0.1LIGHT HAZARD
0.15
0.40EXTRA HAZARD
0.40EXTRA HAZARD
0.40EXTRA HAZARD
0.40EXTRA HAZARD
0.40EXTRA HAZARD
0.1LIGHT HAZARD
0.20161 CLEAN ROOM
HAZ MAT
OVEN
MEDIA BLASTER
PAINT BOOTH
WASH BAY
MACHINE SHOP
ADMINSTRATION
STORAGE ROOM
WELDING SHOP
BOTTLE STORAGE
BOTTLE SHOP
CTK
162 FREEZER
0.20
0.1LIGHT HAZARD
0.20
0.1
0.1
LIGHT HAZARD
LIGHT HAZARD
0.20
LIGHT HAZARD 0.1
0.15
0.1
0.1
0.1
LIGHT HAZARD
LIGHT HAZARD
LIGHT HAZARD
0.1LIGHT HAZARD
0.15ORDINARY HAZARD GR.1
0.1LIGHT HAZARD
0.1LIGHT HAZARD
0.1LIGHT HAZARD
0.1LIGHT HAZARD
0.1LIGHT HAZARD
0.1LIGHT HAZARD
0.1LIGHT HAZARD
0.1LIGHT HAZARD
(GPM/SQ.FT)
DENSITY
MINIMUM
CLASSIFICATION
OCCUPANCY
0.1LIGHT HAZARD
0.40EXTRA HAZARD
0.15
0.15
0.40EXTRA HAZARD
0.40EXTRA HAZARD
0.20
0.20
0.1LIGHT HAZARD
0.20
0.1LIGHT HAZARD
0.15
0.40EXTRA HAZARD
0.40EXTRA HAZARD
0.15
0.20
0.20
0.20
0.1LIGHT HAZARD
0.20
0.1LIGHT HAZARD
0.15
0.15
COMPOSITE SHOP
ADMINSTRATION
CORROSION CONTROL/
COMM. SHOP
ROOM
NO.
NAME
VESTIBULE
LOBBY
OFFICE
OFFICE
CONFERENCE ROOM
WOMEN
LOCKER ROOM
JANITOR STORAGE
MEN
LOCKER ROOM
BREAK ROOM
VENDING
HANGAR BAY
CTK
ADMINISTRATION
ELEC./400 HZ.
NDI SHOP
OFFICE
OFFICE
ELECTRICAL ROOM
COMM. ROOM
OIL ANALYSIS LAB
VESTIBULE
X-RAY VAULT
103 ADMINISTRATION
OCCUPANCY CLASSIFICATION TABLE
VESTIBULE
PROCESSING
VIEWING
CTK/EQUIPMENT
FIRE PROTECTION
MECHANICAL ROOM
ELECTRICAL ROOM
COMM. ROOM
GENERATOR ROOM
WHEEL AND TIRE SHOP
CTK
ADMINISTRATION
REPAIR AND RECL. SHOP
ADMINISTRATION
PNEUDRAULICS SOP
HAZ MAT
TEST STAND
SPIN RIVETER
CTK
ELEN SHOP
ADMINISTRATION
COMM. ROOM
DIFM
BEARING CLEANING ROOM
SHEET METAL SHOP
CTK
SYSTEM TEST CONNECTION ON WET PIPE SYSTEM
SYSTEM TEST CONNECTION ON DRY PIPE SYSTEM
TC-W
TC-D
NOTE:
6-4.
REQUIRED BY MIL-HDBK-1008C SECTION
INSIDE HOSE STREAM SYSTEM IS NOT
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.2
ORDINARY HAZARD GR.1 0.15
ORDINARY HAZARD GR.1 0.15
ORDINARY HAZARD GR.1 0.15
ORDINARY HAZARD GR.2
ORDINARY HAZARD GR.2
ORDINARY HAZARD GR.2
ORDINARY HAZARD GR.2
ORDINARY HAZARD GR.2
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.2
ORDINARY HAZARD GR.2
ORDINARY HAZARD GR.2
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.1 0.15
150 NI-CAD BATTERY
152 OXYGEN
CO2
LOX CART REPAIR
STAIR
151 LEAD ACID BATTERY
0.40
0.1
0.40
0.40
0.40
0.40
EXTRA HAZARD
LIGHT HAZARD
EXTRA HAZARD
EXTRA HAZARD
EXTRA HAZARD
EXTRA HAZARD
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.2
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.2
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.1
ORDINARY HAZARD GR.1
0.15
0.15
0.15
0.15
0.15
HANGAR C-17
POINT FOR
CONNECTION
EXISTING LINE
SUPPLY TANK
EXISTING FIRE WATER
ETL 01-2 0.2
FIRE WATER SUPPLY INFORMATION:
EXISTING FIRE WATER TANK: 500,000 GALLONS
CAPACITY
FIRE PUMPING STATION (BUILDING
3102):
1.
2.
a)
NEW 12" P.I.V.
EXISTING P.I.V.
SERVICE
FIRE WATER
NEW 12"
GENERAL FIRE PROTECTION NOTES
1. HYDRAULIC CALCULATIONS SHOULD INDICATE A MINIMUM MARGIN
OF SAFETY OF 10 PSI (AS PER SECTION 01010, AMENDMENT #2).
2. HOSE ALLOWANCES ARE NOT INCORPORATED IN THE HYDRAULIC
CALCULATIONS BECAUSE THE OUTSIDE FIRE HYDRANTS ARE
SUPPLIED BY THE LOW PRESSURE WATER SYSTEM (DOMESTIC
SYSTEM).
3. FIRE PROTECTION DURING CONSTRUCTION MUST ADHERE TO NFPA
241, SAFEGUARDING CONSTRUCTION, ALTERATION, AND
DEMOLITION OPERATIONS.
4. FITTINGS INTO WHICH SPRINKLERS DROP NIPPLES OR RISER
NIPPLES (SPRIGS) ARE SCREWED SHALL BE THREADED TYPE.
5. PLAIN-END FITTINGS WITH MECHANICAL COUPLING, FITTING WHICH
REQUIRE DRILLINIG A HOLE IN THE PIPE, AND FITTINGS WHICH
USE STEEL GRIPPING DEVICES TO BITE INTO THE PIPE AND
WELDED SEGMENTED FITTINGS SHALL NOT BE USED.
6. WELDED OUTLETS, WELD-O-LETS OR MECHANICAL OUTLETS SHELL
NOT BE USED. WELDED BRANCH OUTLET FITTINGS WITH THREADED
7. INSTALLATION OF ALL FIRE PROTECTION SYSTEMS SHALL BE IN
COMPLIANCE WITH ETL 01-2, ETL 1110-3-484 AND MIL-
HDBK-1008C.
8. PROVIDE PRESSURE GAGE AT WATER SUPPLY ENTRANCE TO THE
BUILDING.
9. PROVIDE PRESSURE GAGES AT INLET AND OUTLET FOR EACH
CHECK VALVE.
10. PROVIDE PRESSURE GAGE AT EACH GENERATOR.
11. PRESSURE GAGE SHALL BE AT LEAST 3-1/2" DIAL AND OIL-
FILLED.
11. FIRE PROTECTION DRAWINGS AND CALCULATIONS SHALL BE
STAMPED AND SIGNED BY A PROFESSIONAL FIRE PROTECTION
ENGINEER.
12. SEISMIC DESIGN AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A PROFESSIONAL ENGINEER.
13. ALL FIRE PROTECTION RELATED SUBMITTAL SHALL BE
GOVERNMENT APPROVED.
DRY PIPE VALVE
PERMITTED FOR PIPING NOT14. SCHEDULE 10 PIPING IS
FS
FIRE PROTECTION DESIGN CRITERIA
2. SPRINKLER SYSTEM:
a) HANGAR CEILING:
- TYPE OF SYSTEM: WET-PIPE, AUTOMATIC
- DENSITY: 0.2 GPM PER SQFT
- AREA OF OPERATION (DESIGN AREA): 5,000 SQFT
- NUMBER OF ZONES: ONE(1) ZONE
- PIPING LAYOUT TYPE: GRID
- SPRINKLER TYPE: QUICK-RESPONSE , K=5.6, TEMPERATURE RATING
- CONTROLS: FLOW SWITCH INTERLOCKED WITH HIGH EXPANSION FOAM
CONTROL PANEL
- ADDITIONAL SPRINKLER HEADS: BELOW THE CATWALK AND EQUIPMENT
PLATFORMS
b) SHOPS AND ADMINISTRATIVE AREAS (SUPPORT BUILDING):
- TYPE OF SYSTEM: WET-PIPE, AUTOMATIC, OVER 100F THE SPACE
- COVERAGE PER OCCUPANCY HAZARD: AS PER TABLE ON THIS DRAWING
- AREA OF OPERATION (DESIGN AREA):
* BELOW MAIN ROOF: 3,000 SQFT X 30% = 3,900 SQFT (ROOF WITH MORE
THAN 15% SLOPE)
* BELOW LOWER CEILINGS: 3,000SQFT
- FOR MINIMUM DENSITY OCCUPANCY CLASSIFICATION AND HOSE
REQUIREMENTS, SEE TABLE ON THIS DRAWING
- SPRINKLER HEAD LOCATIONS: AT THE MAIN CEILING AND BELOW LOWER
LOCAL CEILING AT THE ENCLOSED ROOMS
- ADDITIONAL SPRINKLER HEADS: BELOW THE MEZZANINE FLOOR
3. FOAM SYSTEM AT THE HANGAR:
- TYPE OF SYSTEM: HIGH EXPANSION FOAM
- TIME OF DISCHARGE: 15 MINUTES
- FOAM CONCENTRATE RESERVE: ACTIVE TANK FOR 15 MINUTES (OR FOUR
TIMES THE SUBMERGENCE VOLUM), RESERVE TANK NOT REQUIRED
- SYSTEM TYPE: ONE(1)ZONE CONTROLLED BY A 6" DELUGE VALVE
(ELECTRICAL ACTUATION) AND A 6" PRESSURE PROPORTIONER.
- METHOD OF ACTIVATION: ACTIVATION BY A FLOW SWITCH (WITH BUILT-IN
ADJUSTABLE RETARD TIMER) ON THE SPRINKLER SYSTEM AND/OR MANUAL PULL
STATIONS
- FOAM SUPPLY SYSTEM: BLADDER TANK
- FIRE DEPARTMENT CONNECTIONS: NOT REQUIRED
- DRAFT CURTAINS: THREE (3) AT HANGAR CEILING
- ADDITIONAL PROTECTION TO STRUCTURAL MEMBERS: NOT REQUIRED
- MANUAL FOAM/WATER FIRE HOSE STATION: NOT REQUIRED.
1. GENERAL
PROVIDE DESIGN AND INSTALLATION OF ALL FIRE PROTECTION SYSTEMS
IN ACCORDANCE WITH ETL 01-2, ETL 1110-3-484 AND
MIL-HDBK-1008C
OR GROOVED OUTLETS ARE ACCEPTABLE.
SYSTEM IN HANGAR BAY.
SEE EY SERIES DRAWINGS FOR ADDITIONAL FIRE PROTECTION DRAWINGS
DWG. C-105)
AREA ONLY (SEE
NEW PIPING IN THIS
(NOT IN SCOPE OF WORK)
EXISTING FIRE PUMPING STATION
GOVERNMENT
NEW FIRE PUMP STATION, BY
TR
ANS
Y H
V
Y H
P1 F P
R O
A D
V
V
SYS
TE
M
IN
HANGAR
DELUGE
SP
RIN
KLE
R
95-1
142RD. 2225
R A
D
IN
L H
12"
22452222
S T
148-1
FP
V
AFFEE14
CH
AVE
2 2
F
W H
IT
E
GRISSOM
A P
P R
O A
P
A R
T U
E
A R
A N
R F
A
A P
P R
O A
P
A R
T U
E
A R
A N
R F
A
M
W
14"
HANGAR C-17
14"
FP-001
S
IT
E R
IA
F
O T E
C T
IO
N
T E
D
F P
J O
L L
K
F P .D
A E J R U of
S u b m it t
D e s ig n
D r a
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w
C h e c k
R e v
D a t e
D r a w in g f
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F m e
P t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
SCALE:
1" = 200'-0"
EXISTING HIGH PRESSURE FIRE WATER (HPFW)
SUPPLY SYSTEM - AS BUILT PART PLAN
FP401
N
PLAN NORTH
N
TRUE NORTH
SCALE: 1" = 200'-0"
0 100
HOUSE
LEGEND:
NEW PIPING
EXISTING PIPING
(NOT IN SCOPE OF WORK)
UP
UP
SPRINKLER ZONE #1 (WEST/NORTH) - SUPPORT AREA
SPRINKLER ZONE #3 - HANGAR HIGH EXPANSION FOAM ZONE #4 - HANGAR
RISER #1 WITH FS-R1 RISER #2 WITH FS-R2
RISER #3 WITH FS-R3 RISER #4 WITH PS-2
FS
FS
FS
PS
FS
FS
FS
FS
FS
SPRINKLER ZONE #2 (EAST) - SUPPORT AREA
FS
FS
FS
FS
FS
FS
R3
FS PS
HIGH EXPANSION FOAM - SCHEMATIC DIAGRAM
PG PRESSURE GAUGE
LEGEND
TAMPER SWITCHTS
FLOW SWITCH WITH BUILT-IN
SOLENOID VALVE RELEASE
PRESSURE SWITCH
FS
PS
SV
STRAINER
BASKET
VALVE
SOLENOID
2.
1.
NOTES:
10"
FIN. FLOOR
P.G.
C
CC
SV
PS
TS
F O
A M
PORT
FOAM SAMPLING
6"
6"
1 1/2"
FOAM
TS
TS
8"
6"
6" FOAM PROPORTIONER
8"
F O
A M
PLATFORM (TYPICAL)
MOUNTED INSIDE HANGAR ON METAL
HIGH EXPANSION FOAM GENERATOR
FOAM
O.S. & Y. GATE
VALVE WITH TAMPER
SWITCH (TYPICAL)
4" CONCRETEFLUSHING OUTLET
BLADDER
TANK FOR
FOAM
CONCENTRATE
H.E. FOAM
CONCENTRATE
WATER OPERATED
CONCENTRATE
CONTROL VALVE
PAD (TYPICAL)
DRAIN VALVE
FUTURE
EXPANSION
(VALVED & CAPPED)
6"
DRAIN VALVE
(TYP. FOR ALL
GENERATORS)
PRESSURE
SWITCH ALARM
SURGE TANK
WET SPRINKLER SYSTEM
FROM RISER #3
RISER #4
FOR PIPING CONNECTION BETWEEN FOAM TANK AND
DELUGE VALVE ASSEMBLY SEE DETAIL ON DWG. FP-402
FOR TRIM ARRANGEMENT AT DELUGE VALVE AND
PROPORTIONER ASSEMBLY SEE DETAIL ON DWG. FP-402
ADJUSTABLE RETARD (0-90 SEC.)
8"
8"
TS
P.G.
F O
A M
F O
A M
FOAM
FOAM
FOAM
FOAM
FOAM
FOAM
8"
6"
6"
2 1/2" 3"
3"
2 1/2"
3"
P.G.
TS
2 1/2"
P.G.
TS 2 1/2"
P.G.
TS
P.G.
TS
2 1/2" 3"
2 1/2"
P.G.
TS
3"
TS
P.G.
2 1/2"
2 1/2"
TS
P.G.
P.G.
TS
2 1/2" 3"
2 1/2"
P.G.
TS
3"
TS
P.G.
2 1/2"
2 1/2"
TS
P.G.
3" 3"
3" 3"
3" 3"
WALL
EXTERIOR
B
A 6"
6" DELUGE
VALVE
ROOM, MEDIA BLASTER
PS-2: HANGAR FOAM SYSTEM
ZONE #4 HANGAR HI-EX, RISER #4 WITH PS-2:
FS-R3: HANGAR OVERHEAD SPRINKLERS
ZONE #2 (EAST), RISER #2 WITH FS-R2:
FS-1: SHEET METAL SHOP
FS-2: MEZZANINE - WEST
FS-3: CORROSION CONTROL/COMPOSITE SHOP, CLEAN
PS-1: OUTSIDE CANOPY - WEST
FS-5: WELDING/MACHINE SHOP
FS-6: MEZZANINE - NORTH
FS-7: OFFICES AND LOBBY - NORTH
FS-8: NDI SHOP, OIL ANALYSIS, X-RAY
(PS) SWITCHES SCHEDULE
FLOW (FS) AND PRESSURE
ZONE #3 HANGAR SPRINKLER, RISER #3 WITH FS-R3:
FS-13: ELEN SHOP, BATTERY ROOMS, OXYGEN/CO2,
HAZMAT, LOX CART
FS-12: MEZZANINE - EAST
FS-11: PNEUDRAULICS SHOP
FS-10: REPAIR & RECLAMATION SHOP, OUTSIDE CANOPY -
ROOMS, ELECTRICAL ROOMS
FS-9: WHEEL AND TIRE SHOP, MECHANICAL & SPRINKLER
ZONE #1 (WEST/NORTH), RISER #1 WITH FS-R1:
EAST
FS-4: PAINT BOOTH
HIGH EXPANSION FOAM
ZONE #4 - HANGAR
" VALVED OUTLETS2
(8) 2
SPRINKLER FLOW SIMULATION
HIGH EXPANSION FOAM AND
COMBINED TEST HEADER FOR
(N.C.)
H.E.F. TEST VALVE
TS TS
TS
SPRINKLER SYSTEM - SCHEMATIC DIAGRAM
GRADE
EX
12"
EX
NEW CONNECTION
1O"12"
TS
P.G.
TS
P.I.V.
6"
HPFL
ZONE #3 - HANGAR
FIN. FLOOR
SIAMESE SPRINKLER
CONNECTION
4"x4"x6"
BUILDING
WALL
FLOW SWITCH INTERLOCKED
TO SPRINKLERS
FIRE WATER
HEADER
UTILITY PIT (INSIDE
MECHANICAL ROOM)
SWING CHECK VALVE
EXISTING 14" HIGH
PRESSURE FIRE
LINE (HPFL)
FROM FIRE
PUMPING
STATION
WET SPRINKLER
RISER #3
UNDER THE CATWALK
TS
6"
6"
WITH HIGH EXPANSION FOAM
CONTROL PANEL
6"
WITH PRESSURE
RELIEF TRIM
TS
6"
6"
6"
SURGE
TANK
TO OUTSIDE TEST HEADER
MAIN CEILING (BELOW ROOF)
TS
DRYPIPE
VALVE
TO DRY SYSTEM
1O"
AT WEST CANOPY
6"
3"
CORR/COMP
TS
1"
TEST CONNECTION
TANK
SURGE
6"
6"
6"
1"
TS
TEST CONNECTION
6"MAIN CEILING (BELOW ROOF)
6"6"
6" 6"
O.S. & Y. GATE VALVE
WITH TAMPER SWITCH
6"
1O"
O.S. & Y. GATE VALVE
WITH TAMPER SWITCH
ZONE #1 (WEST/NORTH)
RISER #1 RISER #2
ZONE #2 (EAST)
(TYPICAL)
FOR DETAILED PIPING/ EQUIPMENT
NOTE:
AT SPRINKLER RISERS SEE DWG. FP-401
SIAMESE CHECK
VALVE (TYPICAL)
HPFL HPFL HPFL
(FOR CONT. SEE HEF DIAGRAM)
A
B
R3
FS
WET SPRINKLER WET SPRINKLER
FS
R1
FS
NDI SHOP
4"
FS
4"
FS
4"
FS
4"
OFFICES/LOBBY
NORTH MEZZANINE
WELDING SHOP
PS
FS
FS
SHOP AND STAIR
SHEET METAL 1
FS
MEZZANINE WEST
FS
BOOTH
PAINT
6"
R2
FS
FS
FS
4"
FS
4"
4"
TIRE SHOP
RECLAMATION SHOP
PNEUDRAULICS SHOP
EAST CANOPY
MEZZANINE EAST
4"
FS
4"
ELEN SHOP
FS
6"
TO RISER #4
(H.E.F.)
SURGE
TANK
(N.C.)
WATER TEST VALVE
FP-002
S
T
N
V E
R A
A
G R
A M
S
F
O T E
C T
IO
N
T E
D
F P
J O
L L
F P .D of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
14131210 11 13.37 84 5 62 31 9
(12) TYPICAL HIGH
EXPANSION FOAM
GENERATORS ON CATWALK
ROOF
LOWER CEILING
MEZZANINE WEST
RISER #1 - WEST/ NORTH HANGAR BAY ZONE RISER #2 - EAST
SPRINKLER ZONE #3 AND HI-EX FOAM ZONE #4
SCHEMATIC PIPING DIAGRAM - BUILDING SECTION WEST/ EAST
NOT TO SCALE
MAIN
SYSTEM CROSS
WET SPRINKLER
LOWER CEILING
WET SPRINKLERS
BELOW MEZZANINE
WET SPRINKLER
FEED MAIN FOR
MAIN CEILING
AND LOWER CEILING
TYPICAL GRID
BRANCH AT
HANGAR CEILING
WET SPRINKLER
SYSTEM CROSS
MAIN
SPRINKLERS
UNDER
CATWALK
DRY SPRINKLER
SYSTEM
WET SPRINKLER
FEED MAIN FOR
MAIN CEILING
AND LOWER
CEILING
EXTERIOR
CANOPY
WET SPRINKLERS
BELOW
MEZZANINE
MEZZANINE EAST
ROOF
CATWALK
HANGAR BAY ROOF
CRANE LINE
LOWER CEILING
SPRINKLER HEAD
(TYPICAL)
DRY PIPE VALVE
FP-003
H E
M A
IP
G R
A
C T
IO
N
F
O T E
C T
IO
N
T E
D
F P
J O
L L
F P .D of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
XXXXXXXXXXXX
UP
DRAFT CURTAIN
DRAFT CURTAIN
DRAFT CURTAIN
UPRIGHT SPRINKLER
HEAD BELOW
CATWALK (TYPICAL)
SPRINKLER
PIPING BELOW
CATWALK
(TYPICAL)
2"SPR - UP
1-1/2"SPR-UP
FL
1" 1"1"
1"1" 1"
FL
2"
P
2"
P
2"
U P
2"
P
2"
1- 1/
4"
1- 1/
4"
4"
4"
D N1-
1/ 4"
D N
1"
D N
1- 1/
2"
U P
1"
D N
1- 1/
2"
U P
1- 1/
4"
D N
1- 1/
2"
D N
1- 1/
2"
D N
1- 1/
4"
1["
1\"
1"
D N
2"
D N
2"
D N
2"
D N
2"
J
H
G
F
E
D
C
B
A
C.7
D.3
J
H
G
F
E
D
C
B
A
C.7
D.3
5 6 7 8 9 10 1110.85 6 7 8 9 10 1110.8
FP-101
T W
A L
K
F
O T E
C T
IO
N
T E
D
F P
J O
L L
F P .D
PLAN NORTH
NN
TRUE NORTH
R E
F
F P
M A
T
E R
E F
F P
M A
T
E
R E
F
F P
M A
T
E M
A T
E R
E F
F P
REF. 2/FP103 MATCH LINEREF. 2/FP103REF. 1/FP103
R E
F
P P
R E
F
P P
SCALE: 1/8" = 1'-0"
0 4 8 16
SCALE:
FIRE PROTECTION - AREA A
LOWER LEVEL
FP101
of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
KEY PLAN
AREA C
AREA B AREA A
AREA D
AREA F
CORROSION CONTROL/
COMPOSITE SHOPHAZ MAT
COMM.
ADMIN.
CTK.
OVEN
CLEAN ROOM
FREEZER
SHEET METAL SHOP
STAIR
UP
MEZZANINE CONTOUR
DRY PENDENT
SPRINKLER
PENDENT SPRINKLER
HEAD (TYPICAL)
CONCEALED PENDENT
SPRINKLER HEAD
(TYPICAL)
SPR. LINE AND HEADS
AREA CEILING (TYPICAL)
1"SPR - DROP
TO TC-D
3"SPR - UP
159163
G
F
E
D
C
B
C.7
D.3
1 2 3 43.7
ABCD
PLAN NORTH
NN
TRUE NORTH
SCALE: 1/8" = 1'-0"
0 4 8
SCALE:
FIRE PROTECTION - AREA B
FP102
KEY PLAN
AREA C
AREA B AREA A
AREA D
R E
F
P P
M A
T
CLEANING
MEN
VENDING
LOBBY
OFFICE
OFFICE
JAN.
WOMEN
CONF.
ADMIN.
VEST.
LOCKER ROOM
BREAK ROOM
OIL
ANALYSIS
LAB
X-RAY
VAULT
NDI
SHOP
PROCESS'G
VIEWING
OFFICE
CTK/EQUIP.
VEST.
VEST.
ELEC.
COMM.
ROOF/CANOPY LINE
S H
ES
T
S H O P
EAS
T H
AN
G
AR
1"SPR - DROP
TO TC-D
2"SPR - UP
1"SPR - DROP
TO TC-D
2"SPR - UP
4"SPR - UP
"4" 4"
1" 1"
1" 1"
4"
4"
1" 2"
1"
2"
1"
MEZZANINE CONTOUR
OFFICE
ADMIN.
CTK.
MACHINE SHOP
WELDING SHOP
BOTTLE
STOR.
BOTTLE
STOR.
MEZZANINE CONTOUR
CONCEALED PENDENT
SPRINKLER HEAD
(TYPICAL)
UPRIGHT SPRINKLER
HEAD (TYPICAL)
EXTEND TO EXHAUST PLENUM
AND STACK AND PROVIDE
CONTROL VALVE AND FLOW SWITCH
(WIRED TO LOCAL ALARM BELL TO
MAIN FIRE ALARM PANEL AND
SHUT-DOWN THE COATING MATERIAL
DELIVERY SYSTEM AND SPRAY
APPLICATION) 2"SPR - UP
1-1/2"SPR-UP
1-1/2"SPR - UP
1"SPR - DROP
TO TC-D
3"SPR - UP
1"SPR - DROP
TO TC-D
1-1/2"SPR - UP
1"SPR - DROP
TO TC-D
1-1/2"SPR - UP
DRY PENDENT
SPRINKLER
DRY PENDENT
SPRINKLER
1"1" 1-1/4"
1"1"
M
L
K.7
J
K
J.9
J.1
1 2 3 4 5 63.3
M
L
K.7
K
J.9
J.1
6 7 8 9 10 119.4 9.87.2 7.8
FP-103
E
W
V E
L
F
O T E
C T
IO
N
T E
D
F P
J L
L L
F P
.D
TRUE NORTH
TRUE NORTH
N N
PLAN NORTH
R E
F
F P
M A
T
E
REF. 1/FP101 MATCH LINE
M A
T
E R
E F
F P
MATCH LINE REF. 1/FP101
R E
F
F P
M A
T
E
MATCH LINEREF. 1/FP101REF. 1/FP101REF. 1/FP102MATCH LINE REF. 1/FP102
SCALE: 1/8" = 1'-0"
0 4 8 16
SCALE:
FIRE PROTECTION - AREA D
FP103
SCALE:
FIRE PROTECTION - AREA C
FP103
of
S u b m it t e d b y
D e s ig n
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p
BCD
ABCD
Number:
Reference
Sheet
R e v ie w
C h e c k
R e v
D a t e
D r a w in g f
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
KEY PLAN
AREA C
AREA B AREA A
AREA D
AREA F
TEST STAND
ADMIN.
CTK.
COMM.
LOX CART
REPAIR
PNEUDRAULICS SHOP
ELEN SHOP
DIFM
SPIN RIVETER HAZ MAT
NI-CAD
BATTERY
LEAD ACID
BATTERY
OXYGEN
CO2
MEZZANINE CONTOUR
UPRIGHT SPRINKLER
HEAD (TYPICAL)
CONCEALED PENDENT
SPRINKLER HEAD
(TYPICAL)
(SEE DETAIL)
TO TC-W
1"SPR-DROP
(SEE DETAIL)
TO TC-D
1"SPR-DROP
CORROSION
PROTECTED
SPRINKLER
HEADS
1-1/2"SPR-UP
2-1/2"SPR-UP
1"SPR - DROP
TO TC-D
1-1/2"SPR - UP
1" 1-1/4"
1" 1" 1-1/4" 1-1/2"
1" 1" 1-1/4" 1-1/2"
1-1/2"
1" 1" 1-1/4" 1-1/2"
1-1/2"
1-1/2"
1-1/2" 1"
1" 1"
2-1/2"1
1"1"
1"1"1"
F-FP-101
1"
145 143
153154
MECH.
BEARING
CLEANING
ROOM
FIRE PROTECTION
ELEC./
400 HZ.
REPAIR &
RECLAMATION SHOP
ADMIN.
ADMIN.
CTK.
ELECT. COMM.
GENERATOR
WHEEL & TIRE SHOP
CTK/EQUIP.
CEILING
ABOVE CANOPY
SPRINKLER PIPING
1"SPR - DROP
1-1/2"SPR - UP
1"SPR - DROP
TO TC-D
2-1/2"SPR - UP
2"SPR-UP
1"SPR - DROP
TO TC-D
2"SPR - UP
S H
ES
T
S H O P
EAS
T H
AN
G
AR
FO
AM
1"SPR - DROP
TO TC-D
2"SPR - UP
DRY PENDENT
SPRINKLER
1"1"
1" 2"
1-1/4"
1" 1"
1"1"
1"
1-1/4" 1-1/4"
2-1/2"
1"
1"
132 133
131129
11 12 13 1412.6 13.311.4
M
L.3
L
K.7
K.6
K.5
K
J.8
J
H.6
H
G
F.3
11 12 13 1411.4
F.3
F
E
D.1
D
C.1
C
B
FP-104
E
W
V E
L
F
O T E
C T
IO
N
T E
D
F P
M V
TRUE NORTH
N
PLAN NORTH
N
TRUE NORTH
REF. 2/PP104 MATCH LINE
M A
T
E R
E F
F P
R E
F
P P
R E
F
P P
R E
F
F P
MATCH LINEREF. 1/FP104
M A
T
E R
E F
F P
SCALE: 1/8" = 1'-0"
0 4 8 16
SCALE:
FIRE PROTECTION - AREA E
FP104 SCALE:
FIRE PROTECTION - AREA F
FP104
of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
KEY PLAN
AREA C
AREA B AREA A
AREA D
AREA F
HANGAR BAY
OFFICE ELEC./
400 HZ.
ADMIN.
CTK.
CORROSION CONTROL/
STAIR
LOCKER ROOM
UP
WEST
MEZZ.
EL +30'-0"
HANGAR BAY
HANGAR BAY
OFFICE ELEC./
400 HZ.
ADMIN.
CTK.
CORROSION CONTROL/
STAIR
LOCKER ROOM
UP
201 114
WEST
MEZZ.
EL +30'-0"
HANGAR BAY
HANGAR BAY
OFFICE ELEC./
400 HZ.
ADMIN.
CTK.
CORROSION CONTROL/
STAIR
LOCKER ROOM
UP
LOW PARTITION
(TYPICAL)
F
L
F
L
4"
6" FIDDING MAIN
O
IN
O
IN
2" BRANCHLINE (TYP.)
B
EL
O W
C
AT
W
AL
K
B
EL
O W
C
AT
W
AL
K
B
EL
O W
C
AT
W
AL
K
B
EL
O W
C
AT
W
AL
K
B
EL
O W
C
AT
W
AL
K
B
EL
O W
C
AT
W
AL
K
B
EL
O W
C
AT
W
AL
K
2"
D
TO
EL
O W
C
AT
W
AL
K
201 114 x 0-
2"
D
3"
EZ
Z
B
EL
Z
6"
U P
8"
U P
TO
FO
AM
G
EN
2"
D N
TO
2"
D N
TO
2"
D N
TO
2"
D N
TO
2"
D N
TO
2"
D N
TO
J
H
G
F
E
D
C
B
A
C.7
D.3
J
H
G
F
E
D
C
B
A
C.7
D.3
J
H
G
F
E
D
C
B
A
C.7
D.3
5 6 7 8 9 10 1110.85 6 7 8 9 10 1110.85 6 7 8 9 10 1110.8
FP-105
IL
N G
A R
F
O T E
C T
IO
N
T E
D
F P
M V
TRUE NORTH
R E
F
F P
M A
T
E R
E F
F P
M A
T
E
R E
F
F P
M A
T
E M
A T
E R
E F
F P
REF. 2/FP107 MATCH LINEREF. 2/FP103REF. 1/FP103
R E
F
P P
R E
F
P P
SCALE: 1/8" = 1'-0"
0 4 8 16
SCALE:
FIRE PROTECTION - AREA A
CEILING PLAN HANGAR
FP105
of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n tr a c to rs
A S -B
U
IL
T S
U B
M
IS
S
IO
N
/1
/0
KEY PLAN
AREA C
AREA B AREA A
AREA D
AREA F
AREA E
DWG. FP-401
PIPING SYSTEM SEE DETAIL ON
FOR FLUSHING PROVISIONS ON
NOTE:
MEZZANINE CONTOUR
WEST
MEZZ.
4' (APPROX.) DIA.
EXHAUST DUCT TO
ROOF, ABOVE.
42"X48" DISCHARGE
DUCT TO ROOF, ABOVE.
CORROSION CONTROL/
COMPOSITE SHOP
PAINT BOOTH
WASH
STOR.
MEDIA BLASTER
HAZ MAT
COMM.
ADMIN.
CTK.
OVEN
CLEAN ROOM
FREEZER
SHEET METAL SHOP
STAIR
UP
LOW PARTITION
FULL HEIGHT PARTITION
(TYPICAL)
F L
Z O
N E
W E
Z Z
S
O P
Z O
N E
F L
C O
R R
C O
M P
Z O
N E
F L
6"
3"
3"
4"
4"
(WEST MEZZANINE)
FS-2
(SHEET METAL SHOP)
FS-1
159163 x 0-
2"
D
4"
R Y
P
IP
E
VL
V
3"
D
ED
IA
B
LA
ST
ER
C
LE
AN
R
M
B
EL
Z
B
EL
Z
1"
TE
ST
D R
AI
TE
ST
D R
AI
N
1"
TE
ST
D R
AI
N w
P R
ES
S
SW
4"
B 'F
LY
VL
V w
TA
M P
ER
SW
J
H
G
F
E
D
C
B
A
C.7
D.3
1 2 3 3.7
FP-106
P
IL
A N
F
O T E
C T
IO
N
T E
D
F P
M V
TRUE NORTH
REF. 1/FP107 MATCH LINE
R E
F
F P
M A
T
E R
E F
F P
M A
T
E
SCALE:
FIRE PROTECTION - AREA B
UPPER CEILING PLAN
FP106
SCALE: 1/8" = 1'-0"
0 4 8 16 of
S u b m it t e d b y
D e s ig n e d b y
D r a w n b y
A
D e s c r ip t io n M a r k
D a t e
A p p v d
Sheet
A p r il
BCD
ABCD
Number:
Reference
Sheet
R e v ie w e d b y
C h e c k e d b y
R e v
D a t e
D r a w in g f il e n o
N
R K
N
R K
D
IS
T R
R
G
IN
E E
R S
U .S
A R
G
IN
E
IS
IO
N
Professional Seals:
D r a w in g c o d e
F il e n a m e
P lo t d a t e
D w g s c a le
M C
G U
R
S E
N E
W
J E
R S
E Y
C
N G
A R
A
IR
C R
A
IN
T E
N A
N
C
IL
IT
Y
T o m a s e tt i
G ro u p
A D iv is io n o f T h e T h o rn to n w w w .l z a a s s o c ia te s .c o m
C P y r a m id E n te r p r is e s I n c
E s t.
G e n e ra l, M e c h a n ic a l
M a ri n e C o n…