Amendment_4_-_KC46_BOT_-_Plans.pdf
PDF 134 KB Posted
- Attached to
- KC-46A Add/Alter Bldg. 2319 for Boom Operator Trainer Federal contract opportunity
- Solicitation number
- W912DS-18-B-0021
About this file
PLANS: AMENDMENT 0004, W912DS-18-B-0021
View the file
Other files for this federal contract opportunity
Show all 36
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
Conc.
Pad
T1500
E
EXISTING FACILITY
1500 KVA POWER DISTRIBUTION
TRANSFORMER TO REMAIN.
ACLC-1B
FDS-600HR
N
GRAPHIC SCALE
KEY PLAN
-1 -9
1 14
-A
-L
A
G C
D
B
A
S M
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N S
H E
E T
L
A K
E S
ID
E
C E
N T
R E
W A
Y S
U
IT
E
K N
O X
V
IL
L E
T
N
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
K C
A
B E
D D
O W
N M
C G
U
IR
E A
F B
B U
R L
IN
G T
O N
C O
U N
T Y
N
E W
J E
R S
E Y
S C
A L E
:1
O F
P T
F L -1
W E
R -1
-D
-0
ES101
G
B A
R N
E S
U
L E
D E
Z M
A
G
R
IG
G
IN
S
R
J O
H N
S O
N
J U
L Y
FOR CONSTRUCTION
-2
-E
S
E L E
C T
R
IC
A L
S
IT
E P
L A
N
1/16" = 1'-0"A1
ELECTRICAL SITE PLAN
0 8' 16' 32'
SCALE: 1/16" = 1'-0"
GENERAL SHEET NOTES
A REFER TO SHEET E-001 FOR ABBREVIATIONS, SYMBOLS, AND
GENERAL NOTES.
B CONDUITS, WHERE SHOWN, ARE SHOWN FOR DESIGN INTENT
ONLY, AND ARE NOT TO BE ASSUMED AS INCLUSIVE OF ALL
CONDUITS REQUIRED.
C ANY WIRE TERMINATIONS OR SPLICES WITHIN HANDHOLES
SHALL BE U.L. LISTED FOR SUBMERSIBLE APPLICATIONS.
D REFER TO E-600 SERIES SHEETS FOR LUMINAIRE SCHEDULE
AND PANEL SCHEDULES.
1 CLEAN EXISTING TO BE REUSED BOLLARD WITH A MILD
DETERGENT AND RE-LAMP. RE-INSTALL LUMINAIRE ON NEW
BOLLARD BASE (MATCHING EXISTING DIAMETER, DEPTH, ETC.),
AND EXTEND EXISTING CIRCUIT (MATCHING EXISTING CONDUIT
AND WIRE SIZE) RETAINED FOR REUSE. REFER TO SHEET
ED101 FOR ADDITIONAL INFORMATION.
2 EXISTING POLE AND AREA LUMINAIRE (TYP).
3 EXISTING BOLLARD (TYP).
4 PROVIDE ELECTRICAL EQUIPMENT CONNECTION AND
DISCONNECT FOR NEW OUTDOOR MECHANICAL UNIT,
COORDINATE THE EXACT LOCATION WITH THE MECHANICAL
EQUIPMENT INSTALLER PRIOR TO ROUGH-IN.
5 'SE' SWITCHBOARD, NEW CIRCUIT #5 REFER TO E-601 FOR
CIRCUIT INFORMATION, AND EP112 FOR THE LOCATION OF THE
'SE' SWITCHBOARD.
SHEET KEYED NOTES 0
IS
S U
E F
O R
C O
N S
T R
U C
T
IO
N
/2
/1
R
E S
P O
N S
E T
O C
L
IE
N T
C O
M M
E N
T S
/0 /1
File details come from the government source that posted it.