Floor Areas (square feet) Room or Space (True Occupancy Classification) Level 1 Level 2
Entire Floor Level 71,821 55,891
Classrooms (Group A-3, includes Rooms
5.3.3 & 5.3.56) 5,429 --
General Storage Rooms, Janitors Closets (Group S-1, includes Rooms 11.1.1,
11.1.2 & 11.1.3 on Level 1)
1,324 80
Total Accessory Use (% of Floor Level)
6,753 (9.4%)
(0.1%)
Requirement Allowed/Required Provided Construction Classification Type II-B Type II-B Occupancy Classifications Group B Group S-2
Basic Allowable Height (IBC Table 503) 4 stories & 55 feet
4 stories & 55 feet
Fire Sprinkler Increase (IBC 504.2)1 1 story & 20 feet
1 story & 20 feet
Maximum Allowable Height 5 stories & 75 feet
5 stories & 75 feet
2 stories &
57.75 feet
Basic Allowable Floor Area per Story (IBC Table 503) 23,000 ft2 26,000 ft2
Frontage Increase (IBC 506.2) 100%×[(1,230/1,230)-0.25]×(30/30) = 75% 17,250 ft2 19,500 ft2
Fire Sprinkler Increase (IBC 506.3)1 Multi-story Building = 200% 46,000 ft2 52,000 ft2
Maximum Allowable Area per Story, Separated Uses -- -- --
Maximum Allowable Area per Story, Non-separated Uses 86,250 ft2 97,500 ft2 71,821 ft2
(Level 1) Separated Use Ratios (IBC 302.3.2), -- -- -- Multi-Story Increase (IBC 506.4) Based on 2-Story Building
2 × Area per Story
2 × Area per Story
Maximum Total Building Floor Area 172,500 ft2 195,000 ft2 127,712 ft2
Use & Occupancy Classification
(per NFPA 101®)
Number of Rooms
Maximum Load per
Room
Total Load for All Rooms
Egress Factors Stairways Level In. in.
Patriot GIF, Level 1
Classrooms, Labs, Shops 28 25 478 0.3 0.2
Offices 10 30 80 0.3 0.2
Vehicle Maintenance Training Area
1 45 45 0.3 0.2
Equipment Storage Rooms 4 10 22 0.3 0.2
Assembly Areas 3 100 163 0.3 0.2
Floor Level Totals -- 100 788 -- --
Patriot GIF, Level 2
Classrooms, Labs, Shops 26 25 650 0.3 0.2
Offices 4 38 82 0.3 0.2
Breakroom 1 12 12 0.3 0.2
Floor Level Totals -- 38 744 -- --
Requirement Allowed/Required Provided Construction Classification Type II-B Type II-B Occupancy Classifications Group B Group S-1 Group S-2
Basic Allowable Height (IBC Table 503) 4 stories & 55 feet
3 stories & 55 feet
4 stories & 55 feet
Fire Sprinkler Increase (IBC 504.2)1 1 story & 20 feet
1 story & 20 feet
1 story & 20 feet
Maximum Allowable Height 5 stories & 75 feet
4 stories & 75 feet
5 stories & 75 feet
1 story &
30.5 feet
Basic Allowable Floor Area per Story (IBC Table 503) 23,000 ft2 17,500 ft2 26,000 ft2
Frontage Increase (IBC 506.2) 100%×[(488/488)-0.25]×(30/30) = 75% 17,250 ft2 13,125 ft2 19,500 ft2
Fire Sprinkler Increase (IBC 506.3)1 Single-story Building = 300% 69,000 ft2 52,500 ft2 78,000 ft2
Maximum Allowable Area per Story, Separated Uses -- -- -- --
Maximum Allowable Area per Story, Non-separated Uses 109,250 ft2 83,125 ft2 123,500 ft2 14,560 ft2
Separated Use Ratios (IBC 302.3.2), -- -- -- -- Multi-Story Increase (IBC 506.4) Based on 1-Story Building
1 × Area per Story
1 × Area per Story
1 × Area per Story
Maximum Total Building Floor Area 109,250 ft2 83,125 ft2 123,500 ft2 14,560 ft2
Use & Occupancy Classification
(per NFPA 101®)
Number of Rooms
Maximum Load per
Room
Total Load for All Rooms
Egress Factors Stairways Level In. in.
System Maintenance
Offices 7 7 29 0.3 0.2
General Storage Rooms 4 0 0 0.3 0.2
Rack Storage Area 1 0 0 0.3 0.2
Floor Level Totals -- 7 29 -- --