Building 4100_4101 - As Built Drawings.pdf

PDF 831 KB Posted

Attached to
FORT SILL ACCESS CONTROL
Solicitation number
W9124L20R0023
Issued by

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Floor Areas (square feet) Room or Space (True Occupancy Classification) Level 1 Level 2

Entire Floor Level 71,821 55,891

Classrooms (Group A-3, includes Rooms

5.3.3 & 5.3.56) 5,429 --

General Storage Rooms, Janitors Closets (Group S-1, includes Rooms 11.1.1,

11.1.2 & 11.1.3 on Level 1)

1,324 80

Total Accessory Use (% of Floor Level)

6,753 (9.4%)

(0.1%)

Requirement Allowed/Required Provided Construction Classification Type II-B Type II-B Occupancy Classifications Group B Group S-2

Basic Allowable Height (IBC Table 503) 4 stories & 55 feet

4 stories & 55 feet

Fire Sprinkler Increase (IBC 504.2)1 1 story & 20 feet

1 story & 20 feet

Maximum Allowable Height 5 stories & 75 feet

5 stories & 75 feet

2 stories &

57.75 feet

Basic Allowable Floor Area per Story (IBC Table 503) 23,000 ft2 26,000 ft2

Frontage Increase (IBC 506.2) 100%×[(1,230/1,230)-0.25]×(30/30) = 75% 17,250 ft2 19,500 ft2

Fire Sprinkler Increase (IBC 506.3)1 Multi-story Building = 200% 46,000 ft2 52,000 ft2

Maximum Allowable Area per Story, Separated Uses -- -- --

Maximum Allowable Area per Story, Non-separated Uses 86,250 ft2 97,500 ft2 71,821 ft2

(Level 1) Separated Use Ratios (IBC 302.3.2), -- -- -- Multi-Story Increase (IBC 506.4) Based on 2-Story Building

2 × Area per Story

2 × Area per Story

Maximum Total Building Floor Area 172,500 ft2 195,000 ft2 127,712 ft2

Use & Occupancy Classification

(per NFPA 101®)

Number of Rooms

Maximum Load per

Room

Total Load for All Rooms

Egress Factors Stairways Level In. in.

Patriot GIF, Level 1

Classrooms, Labs, Shops 28 25 478 0.3 0.2

Offices 10 30 80 0.3 0.2

Vehicle Maintenance Training Area

1 45 45 0.3 0.2

Equipment Storage Rooms 4 10 22 0.3 0.2

Assembly Areas 3 100 163 0.3 0.2

Floor Level Totals -- 100 788 -- --

Patriot GIF, Level 2

Classrooms, Labs, Shops 26 25 650 0.3 0.2

Offices 4 38 82 0.3 0.2

Breakroom 1 12 12 0.3 0.2

Floor Level Totals -- 38 744 -- --

Requirement Allowed/Required Provided Construction Classification Type II-B Type II-B Occupancy Classifications Group B Group S-1 Group S-2

Basic Allowable Height (IBC Table 503) 4 stories & 55 feet

3 stories & 55 feet

4 stories & 55 feet

Fire Sprinkler Increase (IBC 504.2)1 1 story & 20 feet

1 story & 20 feet

1 story & 20 feet

Maximum Allowable Height 5 stories & 75 feet

4 stories & 75 feet

5 stories & 75 feet

1 story &

30.5 feet

Basic Allowable Floor Area per Story (IBC Table 503) 23,000 ft2 17,500 ft2 26,000 ft2

Frontage Increase (IBC 506.2) 100%×[(488/488)-0.25]×(30/30) = 75% 17,250 ft2 13,125 ft2 19,500 ft2

Fire Sprinkler Increase (IBC 506.3)1 Single-story Building = 300% 69,000 ft2 52,500 ft2 78,000 ft2

Maximum Allowable Area per Story, Separated Uses -- -- -- --

Maximum Allowable Area per Story, Non-separated Uses 109,250 ft2 83,125 ft2 123,500 ft2 14,560 ft2

Separated Use Ratios (IBC 302.3.2), -- -- -- -- Multi-Story Increase (IBC 506.4) Based on 1-Story Building

1 × Area per Story

1 × Area per Story

1 × Area per Story

Maximum Total Building Floor Area 109,250 ft2 83,125 ft2 123,500 ft2 14,560 ft2

Use & Occupancy Classification

(per NFPA 101®)

Number of Rooms

Maximum Load per

Room

Total Load for All Rooms

Egress Factors Stairways Level In. in.

System Maintenance

Offices 7 7 29 0.3 0.2

General Storage Rooms 4 0 0 0.3 0.2

Rack Storage Area 1 0 0 0.3 0.2

Floor Level Totals -- 7 29 -- --

File details come from the government source that posted it. Updated .