Floor Areas (square feet) Room or Space (True Occupancy Classification) Level 1 Level 2 Level 3

Entire Floor Level 44,083 29,029 16,132

General Storage Rooms, Janitors Closets (Group S-1) 372 1,808 127

Weapons/Arms Storage Rooms (Group S-1) 862 -- --

Elevator Machine Room (Group S-1) 53 -- --

Total Accessory Use (% of Floor Level)

1,287 (2.9%)

1,808 (6.2%)

(0.8%)

Requirement Allowed/Required Provided Construction Classification Type II-B Type II-B Occupancy Classifications Group A-3 Group B Group S-2

Basic Allowable Height (IBC Table 503) 2 stories & 55 feet

4 stories & 55 feet

4 stories & 55 feet

Fire Sprinkler Increase (IBC 504.2)1 1 story & 20 feet

1 story & 20 feet

1 story & 20 feet

Maximum Allowable Height 3 stories & 75 feet

5 stories & 75 feet

5 stories & 75 feet

3 stories & 56 feet

Basic Allowable Floor Area per Story (IBC Table 503) 9,500 ft2 23,000 ft2 26,000 ft2

Frontage Increase (IBC 506.2) 100%×[(848/848)-0.25]×(30/30) = 75% 7,125 ft2 17,250 ft2 19,500 ft2

Fire Sprinkler Increase (IBC 506.3)1 Multi-story Building = 200% 19,000 ft2 46,000 ft2 52,000 ft2

Maximum Allowable Area per Story, Separated Uses 35,625 ft2 -- -- 2,917 ft2

(Level 2) Maximum Allowable Area per Story, Non-separated Uses -- 86,250 ft2 97,500 ft2 44,083 ft2

(Level 1) Separated Use Ratios (IBC 302.3.2), Level 2 0.08 0.30 -- 0.38 < 1.0

Multi-Story Increase (IBC 506.4) Based on 3-Story Building

3 × Area per Story

3 × Area per Story

3 × Area per Story

Maximum Total Building Floor Area 106,875 ft2 258,750 ft2 292,500 ft2 89,244 ft2

Use & Occupancy Classification

(per NFPA 101®)

Number of Rooms

Maximum Load per

Room

Total Load for All Rooms

Egress Factors Stairways Level In. in.

Level 1

Classrooms, Labs, Shops 6 49 109 0.3 0.2

Offices 2 7 14 0.3 0.2

Vehicle Maintenance Training Area

1 24 24 0.3 0.2

Equipment Storage Rooms 4 2 4 0.3 0.2

Floor Level Totals -- 49 151 -- --

Level 2

Classroom (assembly use) 1 58 58 0.3 0.2

Classrooms, Labs, Shops 9 40 278 0.3 0.2

Equipment Storage Rooms 1 0 0 0.3 0.2

Floor Level Totals -- 58 336 -- --

Level 3

Classrooms, Labs, Shops 7 36 186 0.3 0.2

Offices 2 10 20 0.3 0.2

Floor Level Totals -- 36 206 -- --