FY17 649 MUNS MUNITIONS STORAGE MAGAZINES 2093
Amendment 003
ATTACHMENT 9
HAZARDOUS MATERIALS DATA
SIGNATURE:
PREPARED BY: Traver Andreasen (ASB#-4397, PB#-2085)
DEMOLISH IGLOOS
FACILITY:
FACILITY CONSTRUCTION DATE:
REQUESTER:
ORGANIZATION:
THIS REPORT IS NOT TO BE USED FOR BIDDING PURPOSES
REQUESTED:
1460 & 1461
LEAD BASED PAINT
ASBESTOS
JACOB REID
649 MUNS
06 July 2016
LIMITED INSPECTION REPORT
Utah Certified State Inspector: Traver Andreasen (ASB#-4397, PB#-2085)
INSPECTION DATE: 25 July 2016
58356WORK ORDER #:
DEPARTMENT OF THE AIR FORCE
75TH CIVIL ENGINEERING (CEOHA)
HILL AIR FORCE BASE, UTAH
ASBESTOS
21% Chrysotile
15% Chrysotile
Assumed
FRIABILITY *LOCATIONS FOUND
*Per UDAQ definition.
QUANTITY
Waterproofing, Black
Non Friable Category I 1,000 Square
Feet
This inspection was performed in accordance with the Utah Division of Air Quality (DAQ) requirements as found in the Utah Air Quality Rule R307-801-10. This inspection report is required to be on site during all abatement, renovation, and demolition activities. Samples referenced in this report were analyzed by polarized light microscopy (PLM) utilizing method 600R-93-116 by The Science and Engineering Laboratory
(AIHA Acc.#-101572) at Hill Air Force Base, Utah.
The quantities within this report are estimates and are not to be used for bidding purposes.
Table 1
SUMMARY OF ASBESTOS CONTAINING MATERIALS FOUND
MATERIAL TYPE
Category I Non-Friable ACM: Asbestos-containing packings, gaskets, resilient floor coverings, or asphalt roofing products containing more than 1% asbestos as determined by using the method specified in 40 CFR Part 763, Subpart E, Appendix E, Section 1, Polarized Light Microscopy (PLM).
*RACM
*Category I *Category II
DEPARTMENT OF THE AIR FORCE
75 CIVIL ENGINEERING (CEOHA)
HILL AIR FORCE BASE, UTAH
Demolish Igloos 1460 and 1461.Statement of Work:
LIMITED ASBESTOS INSPECTION REPORT INFORMATION
Civil Engineering personnel also reviewed previous asbestos inspection reports of suspect asbestos containing materials (ACM) that could potentially be encountered in the proposed area/areas. The information gathered from all current and previous inspections is shown below by homogenous area.
RACM: Regulated Asbestos-Containing Material (RACM)" means friable ACM, Category I non-friable ACM that has become friable, Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation project operations.
Category II Non-Friable ACM: Any material, excluding Category I non- friable ACM, containing more than 1% asbestos as determined by using the methods specified in 40 CFR Part 763, Subpart E, Appendix E, Section 1, Polarized Light Microscopy (PLM) that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
Building 1461
Sealant, Black Non Friable Category I 1,000 Square
Feet Building 1461
Door Insulation, White
Friable RACM 200 Square
Feet Inside of the Main Doors
A total of 30 6
None Detected GM162313 North Center, Bay None Detected GM162314 Northwest, Exterior None Detected
Waterproofing, Black, Exterior, 1,000 Square Feet
GM162315 Northwest, Exterior None Detected GM162316 Southwest, Exterior
Per Hill AFB requirements, all materials containing any detectable amount of asbestos shall be handled as Asbestos Containing Material (ACM). Table 2 shows the summary of materials containing ≤1% that were identified via "Point Counting". Per EPA/UDAQ ≤1% is not considered to be an asbestos containing material, but special handling/packaging requirements are necessary per OSHA 29CFR 1926.1101 and
29CFR 1910.1001
Thermal System Pipe Fitting Insulation, Brown Sealant, Black Thermal System Pipe Insulation, White/Yellow
Per EPA requirements, all materials analyzed as containing ≤10% asbestos are point counted utilizing EPA method 600/R-93/116 this information is summarized in Table
2.
Table 2.
ASBESTOS
N/A
QUANTITY
N/A
Duct Sealant, White Thermal System Pipe Fitting Insulation, White Waterproofing, Black
The following is a list of the "Suspect Materials" that were sampled as part of this inspection:
suspect materials assessed as part of the inspection.
Sample # samples reference the
Building 1460
Duct Sealant, White, Bay and Exterior, 100 Linear Feet
GM162312
ResultsSample Location
Northwest, Bay
The following table summarizes the sampling data.
Homogenous Building Material, Description, Location, Quantity.
Locations found: Locations of building materials as described in this report indicate where they were found, but do not necessarily mean that these are the only locations where these materials may be encountered during the project.
*LOCATIONS FOUND
N/A N/A
Table 3.
MATERIAL TYPE
None Detected GM162317 North Center, Exterior None Detected
Sealant, Black, Exterior, 1,000 Square Feet GM162318 Northwest, Exterior None Detected GM162319 Northwest, Exterior None Detected GM162320 Southwest, Exterior None Detected
Thermal System Pipe Insulation, White Over Yellow, Exterior, 500 Linear Feet
GM162321 Northwest, Exterior None Detected GM162322 Northwest, Exterior None Detected GM162323 North Center, Exterior None Detected
Thermal System Pipe Fitting Insulation, White, Exterior, 10 Linear Feet
GM162324 Northwest, Exterior None Detected GM162325 Northwest, Exterior None Detected
Thermal System Pipe Fitting Insulation, Brown, Exterior, 10 Linear Feet
GM162326 Northwest, Exterior None Detected
Supervisor: Traver Andreasen: DSN: (801)586-7094
Asbestos/LBP Shop 75 CES(CEOHA)
CONTACT INFORMATION
Table 4.
POTENTIAL FOR ADDITIONAL MATERIALS:
Asbestos/LBP Shop Personnel
DSN:(801)777-8006
This inspection report only encompasses the areas/materials designated within this report. Should the scope of the project be altered in any way or any materials found that are not identified in this report shall require additional assessment. This report cannot be used for any other projects within the building.
Any questions or concerns regarding this inspection report or if any new suspect asbestos containing material (ACM) is encountered, stop work and contact the personnel listed below for further assistance.
Cell: (801)430-3976
Building 1461
Duct Sealant, White, Bay and Exterior, 100 Linear Feet
GM162327 Northwest, Bay None Detected GM162328 Northwest, Bay None Detected GM162329 Northwest, Exterior None Detected
Waterproofing, Black, Exterior, 1,000 Square Feet
GM162330 West Center, Exterior 18% Chrysotile GM162331 Southwest, Exterior 16% Chrysotile GM162332 Southwest, Exterior 21% Chrysotile
Sealant, Black, Exterior, 1,000 Square Feet GM162333 Northwest, Exterior 13% Chrysotile GM162334 North Center, Exterior 15% Chrysotile GM162335 Northwest, Exterior 12% Chrysotile
Thermal System Pipe Insulation, White Over Yellow, Exterior, 500 Linear Feet
GM162336 Northwest, Exterior None Detected GM162337 Northwest, Exterior None Detected GM162338 North Center, Exterior None Detected
Thermal System Pipe Fitting Insulation, White, Exterior, 10 Linear Feet
GM162339 Northwest, Exterior None Detected GM162340 Northwest, Exterior None Detected
Thermal System Pipe Fitting Insulation, Brown, Exterior, 10 Linear Feet
GM162341 Northwest, Exterior None Detected
Table 1.
2-The condition column is the condition only of the painted/coated component (See final page for all readings/samples).
5-This inspection report only encompasses the areas/materials designated within this report. Should the scope of the project be altered in any way or any materials found that are not identified within this report shall require additional assessment. This report cannot be used for any other projects within the building.
4-Any effort to disturb lead paint can create lead dust. Ensure that appropriate abatement, cleanup, and disposal will be accomplished and that appropriate safety measures are taken IAW 29 CFR 1926.62. If you have any questions please feel free to call Traver Andreasen at 777-8006.
3-The U.S. Department of Housing and Urban Development defines Lead-based paint as any paint, varnish, stain, or other applied coating that has 1 mg/cm² as measured by an X-ray Fluorescence (XRF) Analyzer or laboratory analysis or 0.5 percent by weight (5,000 µg/g by dry weight) by laboratory analysis, or more of lead.
All other components tested were less than 0.80 mg/cm².
DEPARTMENT OF THE AIR FORCE
75TH CIVIL ENGINEERING (CEOHA)
HILL AIR FORCE BASE, UTAH
LIMITED LEAD-BASED PAINT IDENTIFICATION REPORT INFORMATION
SCOPE OF WORK: Demolish igloos 1450 and 1461.
Building 1460 Metal Hoist Yellow 2.1 Good
1-table 1 below summarizes the painted/coated building components that tested positive for Lead Based Paint.
These components should be segregated or abated prior to renovation or demolition, and a composite TCLP taken of the waste before disposal.
Component ConditionLead ReadingColor
Metal Door Jamb Grey 4.84 Good Metal Door Grey 12.02 Good Metal Door Brown 6.06 Good
Impeller Bracket Yellow 1.34 Good Metal Angle Red 2.5 Good
Building 1461 Metal Hoist Yellow 2 Good
Metal Door Jamb Grey 4.57 Good Metal Door Grey 8 Good Metal Door Brown 10.69 Good
Impeller Bracket Yellow 1.75 Good Metal Angle Red 2.42 Good
953 0.97 984 1.05 954 1.04 985 0.97 955 1.09 986 0.96
Range: .8 to 1.2 Range: .8 to 1.2 Side Condition Color
North Good Yellow North Good Grey East Good Grey West Good Brown West Good Blue West Good Yellow North Good Red West Good Yellow West Good Brown West Good Brown West Good Brown West Good Grey North Good Yellow East Good Grey West Good Grey West Good Brown West Good Yellow West Good Blue North Good Red West Good Yellow West Good Brown South Good Brown
Pre Calibration PbL (mg/cm²) Calibration
Range Model# Serial #
XL Number Room Structure Substrate PbL(mg/cm2) NEG/POS
Post Calibration
PbL (mg/cm²)
Calibration RangeXRF Analyzer XL2 600 (Serial #56999)
Per 20 Second Reading
Per 20 Second Reading
POS
957 Building 1460 Bay Door Jamb Metal 4.84 POS 956 Building 1460 Bay Hoist Metal 2.10
959 Building 1460 Bay Door Metal 6.06 POS 958 Building 1460 Bay Door Metal 12.02 POS
961 Building 1460 Bay Impeller Bracket Metal 1.34 POS 960 Building 1460 Bay Rail Metal 0.07 NEG
963 Building 1460 Bay 4" Floor Line Concrete 0.01 NEG 962 Building 1460 Bay Angle Metal 2.50 POS
965 Building 1460 Bay Bollard Metal 0.01 NEG 964 Building 1460 Bay Moisture Eliminator Metal 0.01 NEG
967 Building 1460 Bay Bracket Metal 0.04 NEG 966 Building 1460 Bay Steam Post Metal 0.01 NEG
969 Building 1461 Bay Door Jamb Metal 4.57 POS 968 Building 1461 Bay Hoist Metal 2.00 POS
971 Building 1461 Bay Door Metal 10.69 POS 970 Building 1461 Bay Door Metal 8.00 POS
973 Building 1461 Bay Rail Metal 0.04 NEG 972 Building 1461 Bay Impeller Bracket Metal 1.75 POS
975 Building 1461 Bay 4" Floor Line Concrete 0.01 NEG 974 Building 1461 Bay Angle Metal 2.42 POS
977 Building 1461 Bay Moisture Eliminator Metal 0.01 NEG 976 Building 1461 Bay Bollard Metal 0.01 NEG