Boiler_FBE
| Solicitation: W911S6-16-R-0002 | ||||||||||
| Technical Exhibit PP | ||||||||||
| 4/28/16 | ||||||||||
| Building | Building Name | Location in Building | Equipment Description | Manufacturer | Model # | Serial # | Fuel Type | Fuel Rating (MMBTU/hr) | Manufacture Date | Real Property or Test Property |
| 2028 | Bio Lab | West | Hot Water Boiler | Bryan | AB150-S-150-150-FDG | 97197 | Propane | 1.205244 | Contructed prior to June 4, 2010 | Real Property |
| 2028 | Bio Lab | East | Hot Water Boiler | Bryan | AB150-S-150-150-FDG | 97203 | Propane | 1.205244 | Contructed prior to June 4, 2010 | Real Property |
| 2028 | Bio Lab | East | High Pressure Steam Boiler | Bryan | RV700-W-FDG | 97122 | Propane | 5.590933 | Contructed prior to June 4, 2010 | Real Property |
| 2028 | Bio Lab | West | High Pressure Steam Boiler | Bryan | RV700-W-FDG | 97123 | Propane | 5.5909993 | Contructed prior to June 4, 2010 | Real Property |
| 2029 | LSTF | North West | High Pressure Steam Boiler | Kewanee | H3S-150-0 | 861401 | Fuel Oil #2 | 6.278 | 1996 | Real Property |
| 2029 | LSTF | North West | High Pressure Steam Boiler | Kewanee | H3S-200-0 | 861402 | Fuel Oil #2 | 8.37 | 1996 | Real Property |
| 2032 | Baker | East | Hot Water Boiler | Sussman | SSB60 | N4-19065-Y06 | Propane | 1.68 | Contructed prior to June 4, 2010 | Real Property |
| 2032 | Baker | East | High Pressure Steam Boiler | Parker Industrial | 104-40 | L12R43295 | Propane | 1.68 | Contructed prior to June 4, 2010 | Real Property |
| 3036 | Change House | North East | Hot Water Boiler | Bryan | L64WFDO | 63794 | Fuel Oil #2 | 4.3 | 5/19/87 | Real Property |
| 3043 | CARR Equip. Staging | South West | Hot Water Boiler | Columbia | L30 | N/G | Fuel Oil #2 | 0.448 | Contructed prior to June 4, 2010 | Real Property |
| 3048 | Heavy Gun Shop | South West | Hot Water Boiler | H.B. Smith | M86-143 | N/A | Fuel Oil #2 | 0.4501 | 1986 | Real Property |
| 3131 | Vibration Test | South West | Hot Water Boiler | Weil McLain | 978 | CP2946950 | Fuel Oil #2 | 1.007 | 12/4/95 | Real Property |
| 3131 | Vibration Test | South West | Hot Water Boiler | Weil McLain | 978 | CP2946565 | Fuel Oil #2 | 1.007 | 12/4/95 | Real Property |
| 3342 | Expl. Svc. Fac | South East | Hot Water Boiler | H.B. Smith | N/A | C86-125 | Fuel Oil #2 | 0.3583 | 1986 | Real Property |
| 3445 | Lab Gen. Purpose | South Center | Low Pressure Steam Boiler | Hurst | 305 | FB625-15 | Fuel Oil #2 | 5.088 | 5/15/86 | Real Property |
| 3641 | Change House | East Center | Hot Water Heater 250 Gallon | PVI | 40G250A-PG | 88658781 | Propane | 0.032 | 8/1/86 | Real Property |
| 3641 | Change House | East Center | Hot Water Boiler | Lockinvar | N/A | 1864691 | Propane | 0.355 | 8/1/96 | Real Property |
| 4026 | Ditto Fire Station | West | Hot Water Boiler | Smith | 19 Series-5 | F95-471 | Propane | 0.397 | Contructed prior to June 4, 2010 | Real Property |
| 4032 | Weather Station | South East | Hot Water Boiler | National Ray Pack | HI-0183CECAK3AA | 9211104176 | Propane | 0.148 | 11/1/92 | Real Property |
| 4038 | Avn Ops Bldg | South East | Hot Water Boiler | Raypak | W1-0403BCDDRE3A | 9512128618 | Propane | 0.32718 | 12/1/95 | Real Property |
| 4046 | Hangar | South West | Low Pressure Steam Boiler | Superior-Aztec | 5-5-402 | 12548 | Fuel Oil #2 | 2.76 | 1994 | Real Property |
| 4119 | Grid Services Bldg | North Center | Hot Water Boiler | Parker | 0-1583 | 37957 | Fuel Oil #2 | 1.583 | 1989 | Real Property |
| 4122 | Bio Training Building | Inbetween Buildings | Hot Water Boiler | RayPak | H7-2003 | 806283701 | Propane | 0.595 | 6/19/08 | Test Property |
| 4122 | Bio Training Building | Inbetween Buildings | Hot Water Boiler | RayPak | H7-2003 | 806283702 | Propane | 0.595 | 6/19/08 | Test Property |
| 4146 | Remodel Bldg | East Center | Hot Water Boiler | Lockinvar | RBL-500 | 3941217 | Propane | 0.41 | 1994 | Real Property |
| 4156 | Combined Chem Lab | South West | Hot Water Boiler | Bryan | RW 1050-W-FDO | 68989 | Propane | 10.5 | Contructed prior to June 4, 2010 | Real Property |
| 4156 | Combined Chem Lab | South West | Hot Water Boiler | Bryan | RW 1050-W-FDO | 69001 | Propane | 10.5 | Contructed prior to June 4, 2010 | Real Property |
| 4165 | Combined Chem Lab | South West | Hot Water Boiler | Bryan | RV500-W-FDG | 95651 | Propane | 3.984001 | Contructed prior to June 4, 2010 | Real Property |
| 4165 | Combined Chem Lab | South West | Hot Water Boiler | Bryan | RV500-W-FDG | 95650 | Propane | 3.984001 | Contructed prior to June 4, 2010 | Real Property |
| 4168 | Ditto Fitness Center | West Center | Hot Water Boiler | Ajax | WF0250 | 50895 | Fuel Oil #2 | 0.205 | Contructed prior to June 4, 2010 | Real Property |
| 4215 | Ditto Decon Facility | South West | Hot Water Boiler | Weil McLain | 778 Series | WDBOL 4215-1 | Fuel Oil #2 | 0.764 | Contructed prior to June 4, 2010 | Real Property |
| 4218 | Battery Shop | East Center | Hot Water Boiler | Parker | O-1675C1536 | 37598 | Fuel Oil #2 | 1.675 | 1989 | Real Property |
| 4223 | Sampler Rep/Storage | South Center | Hot Water Boiler | Rite | 150-WO | 8620412 | Fuel Oil #2 | 1.5 | 1986 | Real Property |
| 4229 | Tech Laundry | North West | High Pressure Steam Boiler | Superior | 4-X-508 | 12091 | Fuel Oil #2 | 3.3479 | 1993 | Real Property |
| 4229 | Tech Laundry | North West | High Pressure Steam Boiler | Superior | 4-X-508 | 12087 | Fuel Oil #2 | 3.3479 | 1993 | Real Property |
| 4231 | Calibration Facility | North East | Hot Water Boiler | Teledyne Lars | JUI-160H | N/A | Propane | 0.134 | Contructed prior to June 4, 2010 | Real Property |
| 4258 | Photo Optics Lab | West Center | Hot Water Boiler | Smith | F95-787 | N/A | Fuel Oil #2 | 0.744 | 1995 | Real Property |
| 4258 | Photo Optics Lab | Middle Center | Hot Water Boiler | Weil McLain | Ultra 310 | N/G | Propane | 0.31 | Contructed prior to June 4, 2010 | Real Property |
| 4258 | Photo Optics Lab | Middle Center | Hot Water Boiler | Weil McLain | Ultra 310 | N/G | Propane | 0.31 | Contructed prior to June 4, 2010 | Real Property |
| 4258 | Photo Optics Lab | Middle Center | Hot Water Boiler | Weil McLain | Ultra 310 | N/G | Propane | 0.31 | Contructed prior to June 4, 2010 | Real Property |
| 4357 | Vehicle Maint (New) | North West | Hot Water Boiler | Bryan | CL180-W-FDO | 74957 | Fuel Oil #2 | 0.9 | 11/29/93 | Real Property |
| 4515 | Security | South Center | Hot Water Boiler | Burnham | V-904 | 7592502 | Fuel Oil #2 | 0.404 | Contructed prior to June 4, 2010 | Real Property |
| 4531 | Kuddes Building | West Center | Hot Water Boiler | Weil McClain | 88-680 | Fuel Oil #2 | 1.2 | 1994 | Real Property | |
| 4541 | First Aid Station | North Center | Hot Water Boiler | Weil McLain | PFG-7-PI | 3 | Propane | 0.3042 | 7/81 - 1/89 | Real Property |
| 4545 | Ditto Diner | South East | Hot Water Boiler | Seneca | 13-X-150 | 11875 | Fuel Oil #2 | 1.2 | 1993 | Real Property |
| 4551 | Change House | North West | Hot Water Boiler | Burnham | 4FW-675A40LB | 17720 | Fuel Oil #2 | 5.657 | 1987 | Real Property |
| 4561 | TAP Laundry | South Center | Low Pressure Steam Boiler | Superior | 3-5-201 | 12547 | Fuel Oil #2 | 1.39916 | 1994 | Real Property |
| 5100 | Post Chapel | South | Low Pressure Steam Boiler | Burnham | E-20 | 9013100 | Fuel Oil #2 | 0.67 | Contructed prior to June 4, 2010 | Real Property |
| 5109 | Fitness Center | South | Hot Water Boiler | Rite | 425WG | 23858 | Fuel Oil #2 | 3.375 | 1993 | Real Property |
| 5114 | Commissary | North West | Hot Water Boiler | Smith | 19SERIES-10 | F94-556 | Fuel Oil #2 | 0.83 | 1994 | Real Property |
| 5116 | New Health Clinic | West | Hot Water Boiler | Bryan | HECLM9-W-FD-6 | 93907 | Propane | 0.30131 | 2006 | Real Property |
| 5124 | Community Center | North | Hot Water Boiler | Weil McLain | BG-488-WS | 1727079 | Fuel Oil #2 | 0.81 | Contructed prior to June 4, 2010 | Real Property |
| 5126 | Theatre | North | Hot Water Boiler | Smith | 19 SERIES-7 | F94-874 | Fuel Oil #2 | 0.57 | Contructed prior to June 4, 2010 | Real Property |
| 5132 | Civilian Dormitory | South West | Hot Water Boiler | Smith | 28A-7 | N97-70 | Fuel Oil #2 | 1.477 | 1997 | Real Property |
| 5140 | Civilian Dormitory | North East | Hot Water Boiler | Weil McClain | 80 Series 1-680 | CP6859484 | Fuel Oil #2 | 1.2 | Contructed prior to June 4, 2010 | Real Property |
| 5212 | Fire Station | South | Hot Water Boiler | Smith | 19SERIES-4 | F94-779 | Fuel Oil #2 | 0.31 | 1994 | Real Property |
| 5212 | Fire Station | South | Hot Water Boiler | Smith | 19SERIES-4 | F94-902 | Fuel Oil #2 | 0.31 | 1994 | Real Property |
| 5220 | Base Officers Qtrs. | Downstairs | Low Pressure Steam Boiler | Weil McLain | 776 | N/A | Propane | 0.488 | 1975 - 1993 | Real Property |
| 5228 | Visiting Officers Qtrs | Downstairs | Low Pressure Steam Boiler | Weil McLain | 776 | N/A | Propane | 0.488 | 1975 - 1993 | Real Property |
| 5228 | Visiting Officers Qtrs | Downstairs | Low Pressure Steam Boiler | Weil McLain | 776 | N/A | Propane | 0.488 | 1975 - 1993 | Real Property |
| 5230 | Community Club | North West | High Pressure Steam Boiler | Columbia | CT-25 | 145148 | Fuel Oil #2 | 0.83697 | 9/1/95 | Real Property |
| 5230 | Community Club | North West | High Pressure Steam Boiler | Columbia | CT-25 | 145148 | Fuel Oil #2 | 1.05 | 1995 | Real Property |
| 5230 | Community Club | North West | High Pressure Steam Boiler | Columbia | CT-35 | 145286 | Fuel Oil #2 | 1.47 | 1995 | Real Property |
| 5240 | EV Police Station | Basement Interior middle | Hot Water Boiler | Furtera III | MB750 | 71364964 | Propane | 0.653 | Contructed prior to June 4, 2010 | Real Property |
| 5240 | EV Police Station | Basement Interior middle | Hot Water Boiler | Furtera III | MB751 | 71364965 | Propane | 0.653 | Contructed prior to June 4, 2010 | Real Property |
| 5326 | Dugway Mall | North Center | Low Pressure Boiler | Burnham | EL-40-0-PF | 22156 | Fuel Oil #2 | 1.402 | 1993 | Real Property |
| 5330 | Administration | West | Low Pressure Steam Boiler | Weil McClain | 88-Series 2-688 | CP6858155 | Fuel Oil #2 | 1.413 | Contructed prior to June 4, 2010 | Real Property |
| 5330 | Administration | West | Low Pressure Steam Boiler | Smith | Series 284-9 | N-95-323 | Fuel Oil #2 | 1.733 | Contructed prior to June 4, 2010 | Real Property |
| 5444 | Communication Center | Middle South | Hot Water Boiler | Kewanee | M-155-KO | R8136 | Fuel Oil #2 | 2.105 | 9/28/85 | Real Property |
| 5460 | Machine Shop | West Center | Low Pressure Boiler | Weil McClain | 88 - Series 2688 | CP6859192 | Fuel Oil #2 | 1.229 | Contructed prior to June 4, 2010 | Real Property |
| 5460 | Machine Shop | West Center | Low Pressure Boiler | Weil McClain | 88 - Series 888 | N/G | Fuel Oil #2 | 1.728 | Contructed prior to June 4, 2010 | Real Property |
| 5460 | Skill Development Ctr. | West | Low Pressure Steam Boiler | Weil McLain | 888 | N/A | Propane | 1.904 | 2/85 - present | Real Property |
| 5460 | Skill Development Ctr. | West | Low Pressure Steam Boiler | Weil McLain | 888 | N/A | Propane | 1.904 | 2/85 - present | Real Property |
| 5468 | Motor Pool | West Center | Low Pressure Boiler | Peerless | SC/SCT/06-W/S | 697504-201310 | Fuel Oil #2 | 0.409 | Oct-13 | Real Property |
| 5474 | Base Operations | South Middle | Hot Water Boiler | Peerless | LCE-16 | LC-010363-696 | Fuel Oil #2 | 2.125 | 6/1/96 | Real Property |
| 5802 | Auto Craft Shop | South West | Hot Water Boiler | RayPak | B-7777 | 72L0025014 | Fuel Oil #2 | 1.3 | 1972 | Real Property |
| 8027 | MTF | South East | High Pressure Steam Boiler | Cleaver Brook | CB-7010-250 | L86880 | Propane | 10.5 | Contructed prior to June 4, 2010 | Real Property |
| 8027 | MTF | South East | High Pressure Steam Boiler | Cleaver Brook | CB-7010-250 | L86879 | Propane | 10.5 | Contructed prior to June 4, 2010 | Real Property |
Major_HAP Overview
| Solicitation: W911S6-16-R-0002 | ||||||||||||||
| Technical Exhibit PP | ||||||||||||||
| 4/28/16 | ||||||||||||||
| Building | Building Name | Location in Building | Equipment Description | Manufacturer | Model # | Serial # | Fuel Type | Fuel Rating (MMBTU/hr) | Manufacture Date | Subcatagory | Summary of Requirements | Comments | ||
| 4168 | Ditto Fitness Center | West Center | Hot Water Boiler | Ajax | WF0250 | 50895 | Fuel Oil #2 | 0.205 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5212 | Fire Station | South | Hot Water Boiler | Smith | 19SERIES-4 | F94-779 | Fuel Oil #2 | 0.31 | 1994 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5212 | Fire Station | South | Hot Water Boiler | Smith | 19SERIES-4 | F94-902 | Fuel Oil #2 | 0.31 | 1994 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 3342 | Expl. Svc. Fac | South East | Hot Water Boiler | H.B. Smith | N/A | C86-125 | Fuel Oil #2 | 0.3583 | 1986 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4515 | Security | South Center | Hot Water Boiler | Burnham | V-904 | 7592502 | Fuel Oil #2 | 0.404 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5468 | Motor Pool | West Center | Low Pressure Boiler | Peerless | SC/SCT/06-W/S | 697504-201310 | Fuel Oil #2 | 0.409 | Oct-13 | New small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on after June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
3043 CARR Equip. Staging South West Hot Water Boiler Columbia L30 N/G Fuel Oil #2 0.448 Contructed prior to June 4, 2010 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 3048 | Heavy Gun Shop | South West | Hot Water Boiler | H.B. Smith | M86-143 | N/A | Fuel Oil #2 | 0.4501 | 1986 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5126 | Theatre | North | Hot Water Boiler | Smith | 19 SERIES-7 | F94-874 | Fuel Oil #2 | 0.57 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5100 | Post Chapel | South | Low Pressure Steam Boiler | Burnham | E-20 | 9013100 | Fuel Oil #2 | 0.67 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
4258 Photo Optics Lab West Center Hot Water Boiler Smith F95-787 N/A Fuel Oil #2 0.744 1995 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4215 | Ditto Decon Facility | South West | Hot Water Boiler | Weil McLain | 778 Series | WDBOL 4215-1 | Fuel Oil #2 | 0.764 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5124 | Community Center | North | Hot Water Boiler | Weil McLain | BG-488-WS | 1727079 | Fuel Oil #2 | 0.81 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5114 | Commissary | North West | Hot Water Boiler | Smith | 19SERIES-10 | F94-556 | Fuel Oil #2 | 0.83 | 1994 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5230 | Community Club | North West | High Pressure Steam Boiler | Columbia | CT-25 | 145148 | Fuel Oil #2 | 0.83697 | 9/1/95 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on after June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
4357 Vehicle Maint (New) North West Hot Water Boiler Bryan CL180-W-FDO 74957 Fuel Oil #2 0.9 11/29/93 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 3131 | Vibration Test | South West | Hot Water Boiler | Weil McLain | 978 | CP2946950 | Fuel Oil #2 | 1.007 | 12/4/95 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 3131 | Vibration Test | South West | Hot Water Boiler | Weil McLain | 978 | CP2946565 | Fuel Oil #2 | 1.007 | 12/4/95 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5230 | Community Club | North West | High Pressure Steam Boiler | Columbia | CT-25 | 145148 | Fuel Oil #2 | 1.05 | 1995 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
4531 Kuddes Building West Center Hot Water Boiler Weil McClain 88-680 Fuel Oil #2 1.2 1994 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4545 | Ditto Diner | South East | Hot Water Boiler | Seneca | 13-X-150 | 11875 | Fuel Oil #2 | 1.2 | 1993 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5140 | Civilian Dormitory | North East | Hot Water Boiler | Weil McClain | 80 Series 1-680 | CP6859484 | Fuel Oil #2 | 1.2 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5460 | Machine Shop | West Center | Low Pressure Boiler | Weil McClain | 88 - Series 2688 | CP6859192 | Fuel Oil #2 | 1.229 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
5802 Auto Craft Shop South West Hot Water Boiler RayPak B-7777 72L0025014 Fuel Oil #2 1.3 1972 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4561 | TAP Laundry | South Center | Low Pressure Steam Boiler | Superior | 3-5-201 | 12547 | Fuel Oil #2 | 1.39916 | 1994 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
5326 Dugway Mall North Center Low Pressure Boiler Burnham EL-40-0-PF 22156 Fuel Oil #2 1.402 1993 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
5330 Administration West Low Pressure Steam Boiler Weil McClain 88-Series 2-688 CP6858155 Fuel Oil #2 1.413 Contructed prior to June 4, 2010 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
5230 Community Club North West High Pressure Steam Boiler Columbia CT-35 145286 Fuel Oil #2 1.47 1995 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
5132 Civilian Dormitory South West Hot Water Boiler Smith 28A-7 N97-70 Fuel Oil #2 1.477 1997 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4223 | Sampler Rep/Storage | South Center | Hot Water Boiler | Rite | 150-WO | 8620412 | Fuel Oil #2 | 1.5 | 1986 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4119 | Grid Services Bldg | North Center | Hot Water Boiler | Parker | 0-1583 | 37957 | Fuel Oil #2 | 1.583 | 1989 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4218 | Battery Shop | East Center | Hot Water Boiler | Parker | O-1675C1536 | 37598 | Fuel Oil #2 | 1.675 | 1989 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
5460 Machine Shop West Center Low Pressure Boiler Weil McClain 88 - Series 888 N/G Fuel Oil #2 1.728 Contructed prior to June 4, 2010 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
5330 Administration West Low Pressure Steam Boiler Smith Series 284-9 N-95-323 Fuel Oil #2 1.733 Contructed prior to June 4, 2010 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
5444 Communication Center Middle South Hot Water Boiler Kewanee M-155-KO R8136 Fuel Oil #2 2.105 9/28/85 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
5474 Base Operations South Middle Hot Water Boiler Peerless LCE-16 LC-010363-696 Fuel Oil #2 2.125 6/1/96 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
4046 Hangar South West Low Pressure Steam Boiler Superior-Aztec 5-5-402 12548 Fuel Oil #2 2.76 1994 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
4229 Tech Laundry North West High Pressure Steam Boiler Superior 4-X-508 12091 Fuel Oil #2 3.3479 1993 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
4229 Tech Laundry North West High Pressure Steam Boiler Superior 4-X-508 12087 Fuel Oil #2 3.3479 1993 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
5109 Fitness Center South Hot Water Boiler Rite 425WG 23858 Fuel Oil #2 3.375 1993 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
3036 Change House North East Hot Water Boiler Bryan L64WFDO 63794 Fuel Oil #2 4.3 5/19/87 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
3445 Lab Gen. Purpose South Center Low Pressure Steam Boiler Hurst 305 FB625-15 Fuel Oil #2 5.088 5/15/86 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
2029 LSTF North West High Pressure Steam Boiler Kewanee H3S-150-0 861401 Fuel Oil #2 6.278 1996 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
2029 LSTF North West High Pressure Steam Boiler Kewanee H3S-200-0 861402 Fuel Oil #2 8.37 1996 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
3641 Change House East Center Hot Water Heater 250 Gallon PVI 40G250A-PG 88658781 Propane 0.032 8/1/86 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
4231 Calibration Facility North East Hot Water Boiler Teledyne Lars JUI-160H N/A Propane 0.134 Contructed prior to June 4, 2010 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4032 | Weather Station | South East | Hot Water Boiler | National Ray Pack | HI-0183CECAK3AA | 9211104176 | Propane | 0.148 | 11/1/92 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5116 | New Health Clinic | West | Hot Water Boiler | Bryan | HECLM9-W-FD-6 | 93907 | Propane | 0.30131 | 2006 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4541 | First Aid Station | North Center | Hot Water Boiler | Weil McLain | PFG-7-PI | 3 | Propane | 0.3042 | 7/81 - 1/89 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4258 | Photo Optics Lab | Middle Center | Hot Water Boiler | Weil McLain | Ultra 310 | N/G | Propane | 0.31 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4258 | Photo Optics Lab | Middle Center | Hot Water Boiler | Weil McLain | Ultra 310 | N/G | Propane | 0.31 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4258 | Photo Optics Lab | Middle Center | Hot Water Boiler | Weil McLain | Ultra 310 | N/G | Propane | 0.31 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4038 | Avn Ops Bldg | South East | Hot Water Boiler | Raypak | W1-0403BCDDRE3A | 9512128618 | Propane | 0.32718 | 12/1/95 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4026 | Ditto Fire Station | West | Hot Water Boiler | Smith | 19 Series-5 | F95-471 | Propane | 0.397 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 4146 | Remodel Bldg | East Center | Hot Water Boiler | Lockinvar | RBL-500 | 3941217 | Propane | 0.41 | 1994 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5220 | Base Officers Qtrs. | Downstairs | Low Pressure Steam Boiler | Weil McLain | 776 | N/A | Propane | 0.488 | 1975 - 1993 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
5228 Visiting Officers Qtrs Downstairs Low Pressure Steam Boiler Weil McLain 776 N/A Propane 0.488 1975 - 1993 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
5228 Visiting Officers Qtrs Downstairs Low Pressure Steam Boiler Weil McLain 776 N/A Propane 0.488 1975 - 1993 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
4122 Bio Training Building Inbetween Buildings Hot Water Boiler RayPak H7-2003 806283701 Propane 0.595 6/19/08 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
4122 Bio Training Building Inbetween Buildings Hot Water Boiler RayPak H7-2003 806283702 Propane 0.595 6/19/08 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
5240 EV Police Station Basement Interior middle Hot Water Boiler Furtera III MB750 71364964 Propane 0.653 Contructed prior to June 4, 2010 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 5240 | EV Police Station | Basement Interior middle | Hot Water Boiler | Furtera III | MB751 | 71364965 | Propane | 0.653 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 2028 | Bio Lab | West | Hot Water Boiler | Bryan | AB150-S-150-150-FDG | 97197 | Propane | 1.205244 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 2028 | Bio Lab | East | Hot Water Boiler | Bryan | AB150-S-150-150-FDG | 97203 | Propane | 1.205244 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
| May meet exemption under hot water heater - additional information required to determine. | |||||||||||||
| 2032 | Baker | East | Hot Water Boiler | Sussman | SSB60 | N4-19065-Y06 | Propane | 1.68 | Contructed prior to June 4, 2010 | Existing small major source boilers and process heaters | i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr | Coal, Biomass, Oil, and Gas | • Tune‐up every other year |
• No numeric emission limits
• One‐time energy assessment
2032 Baker East High Pressure Steam Boiler Parker Industrial 104-40 L12R43295 Propane 1.68 Contructed prior to June 4, 2010 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
5460 Skill Development Ctr. West Low Pressure Steam Boiler Weil McLain 888 N/A Propane 1.904 2/85 - present Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
5460 Skill Development Ctr. West Low Pressure Steam Boiler Weil McLain 888 N/A Propane 1.904 2/85 - present Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
4165 Combined Chem Lab South West Hot Water Boiler Bryan RV500-W-FDG 95651 Propane 3.984001 Contructed prior to June 4, 2010 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
4165 Combined Chem Lab South West Hot Water Boiler Bryan RV500-W-FDG 95650 Propane 3.984001 Contructed prior to June 4, 2010 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
2028 Bio Lab East High Pressure Steam Boiler Bryan RV700-W-FDG 97122 Propane 5.590933 Contructed prior to June 4, 2010 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
2028 Bio Lab West High Pressure Steam Boiler Bryan RV700-W-FDG 97123 Propane 5.5909993 Contructed prior to June 4, 2010 Existing small major source boilers and process heaters i.e., commenced construction or reconstruction of the boiler on or before June 4, 2010; less than 10 MMBtu/hr Coal, Biomass, Oil, and Gas • Tune‐up every other year
• No numeric emission limits
• One‐time energy assessment
4156 Combined Chem Lab South West Hot Water Boiler Bryan RW 1050-W-FDO 68989 Propane 10.5 Contructed prior to June 4, 2010 Existing large major source boilers and process heaters i.e., commenced construction or reconstruction of the unit on or before June 4, 2010; heat input capacity of 10 MMBtu/hr or greater Clean Gas (Natural gas, refinery gas) • Tune‐up every year
• No numeric emission limits
• One‐time energy assessment
4156 Combined Chem Lab South West Hot Water Boiler Bryan RW 1050-W-FDO 69001 Propane 10.5 Contructed prior to June 4, 2010 Existing large major source boilers and process heaters i.e., commenced construction or reconstruction of the unit on or before June 4, 2010; heat input capacity of 10 MMBtu/hr or greater Clean Gas (Natural gas, refinery gas) • Tune‐up every year
• No numeric emission limits
• One‐time energy assessment
8027 MTF South East High Pressure Steam Boiler Cleaver Brook CB-7010-250 L86880 Propane 10.5 Contructed prior to June 4, 2010 Existing large major source boilers and process heaters i.e., commenced construction or reconstruction of the unit on or before June 4, 2010; heat input capacity of 10 MMBtu/hr or greater Clean Gas (Natural gas, refinery gas) • Tune‐up every year
• No numeric emission limits
• One‐time energy assessment
8027 MTF South East High Pressure Steam Boiler Cleaver Brook CB-7010-250 L86879 Propane 10.5 Contructed prior to June 4, 2010 Existing large major source boilers and process heaters i.e., commenced construction or reconstruction of the unit on or before June 4, 2010; heat input capacity of 10 MMBtu/hr or greater Clean Gas (Natural gas, refinery gas) • Tune‐up every year
• No numeric emission limits
• One‐time energy assessment
| 4551 | Change House | North West | Hot Water Boiler | Burnham | 4FW-675A40LB | 17720 | Fuel Oil #2 | 5.657 | 1987 |
| 4122 | Bio Training Building | Inbetween Buildings | Hot Water Boiler | RayPak | H7-2003 | 806283701 | Propane | 0.595 | 6/19/08 |
| 4122 | Bio Training Building | Inbetween Buildings | Hot Water Boiler | RayPak | H7-2003 | 806283702 | Propane | 0.595 | 6/19/08 |
| 3641 | Change House | East Center | Hot Water Boiler | Lockinvar | N/A | 1864691 | Propane | 0.355 | 8/1/96 |
| 2028 | Baker | High Pressure Boiler | Cemline - Clean System | V45USG818 | 61818 |
| 2029 | Burns Road Baker | High Pressure Boiler | Cemline Corp | V45USG 818 | N/A |
| 5474 | Frontage Road | High Pressure Boiler | Cleaver Brook | PSM-50-M | 6356 |
| 4070 | Tucker Road | Hot Water Boiler | HTP | EL110N | L12R43295 |
| Boiler means an enclosed device using controlled flame combustion and having the primary purpose of recovering thermal energy in the form of steam or hot water. Controlled flame combustion refers to a steady-state, or near steady-state, process wherein fuel and/or oxidizer feed rates are controlled. A device combusting solid waste, as defined in §241.3 of this chapter, is not a boiler unless the device is exempt from the definition of a solid waste incineration unit as provided in section 129(g)(1) of the Clean Air Act. Waste heat boilers are excluded from this definition. |
Process heater means an enclosed device using controlled flame, and the unit's primary purpose is to transfer heat indirectly to a process material (liquid, gas, or solid) or to a heat transfer material (e.g., glycol or a mixture of glycol and water) for use in a process unit, instead of generating steam. Process heaters are devices in which the combustion gases do not come into direct contact with process materials. A device combusting solid waste, as defined in §241.3 of this chapter, is not a process heater unless the device is exempt from the definition of a solid waste incineration unit as provided in section 129(g)(1) of the Clean Air Act. Process heaters do not include units used for comfort heat or space heat, food preparation for on-site consumption, or autoclaves. Waste heat process heaters are excluded from this definition.
Hot Water Heaters
| Solicitation: W911S6-16-R-0002 | ||||||||||||
| Technical Exhibit PP | ||||||||||||
| 4/28/16 | ||||||||||||
| Water Heater No More Than 120 Gallons (Exempt) | ||||||||||||
| Building | Building Name | Location in Building | Equipment Description | Manufactuer | Model# | Serial# | Fuel Type | Rated MMBTU | Manufacture Date | Gallons | Manufacture Date | Real Property or Test Property |
| 4239 | Remodel Bldg | In Electrical Closet | Hot Water Heater | Ruud | P40-7P | RULP198114388 | Propane | 0.034 | N/G | <100 | 2/2/12 | Real Property |
| 5240 | Applied Instr. Bldg. | Downstairs | Hot Water Heater | Ruud | P50-2P | 0894A33226 | Propane | 0.036 | 8/1/94 | <100 | 8/1/94 | Real Property |
| 5240 | Applied Instr. Bldg. | Downstairs | Hot Water Heater | Ruud | P50-2P | 0894A33227 | Propane | 0.036 | 8/1/94 | <100 | 8/1/94 | Real Property |
| 5438 | Security Office | North East | Hot Water Boiler | Smith | 19SERIES-4 | F92-210 | Fuel Oil #2 | 0.31 | 6/14/05 | <100 | Real Property | |
| 3445 | Lab Gen. Purpose | South Center | Hot Water Heater | Bock | 241E | 99013046T | Fuel Oil #2 | 0.2839097242 | 1/1/99 | 100 | 1/1/99 | Real Property |
| 4215 | Ditto Decon Team Facility | South West | Hot Water Heater | Weil Mclain | 778 | N/G | Fuel Oil #2 | 0.764 | N/G | 119 | Real Property | |
| 5212 | Fire Station | South | Hot Water Heater | A.O. Smith | COF199930 | MK960591-44930 | Fuel Oil #2 | 0.199 | 10/1/96 | 120 | 10/1/96 | Real Property |
| Hot water heater means a closed vessel with a capacity of no more than 120 U.S. gallons in which water is heated by combustion of gaseous, liquid, or biomass/bio-based solid fuel and is withdrawn for use external to the vessel. Hot water boilers (i.e., not generating steam) combusting gaseous, liquid, or biomass fuel with a heat input capacity of less than 1.6 million Btu per hour are included in this definition. The 120 U.S. gallon capacity threshold to be considered a hot water heater is independent of the 1.6 MMBtu/hr heat input capacity threshold for hot water boilers. Hot water heater also means a tankless unit that provides on demand hot water. |