TECH LIBRARY 1 SVPP Supplier Manuals Rockwell 1444-td001_-en-p.pdf
PDF 1 MB Posted
- Attached to
- Launch Operations Support Contract (LOSC) Request for Proposal (RFP) – FINAL Federal contract opportunity
- Solicitation number
- FA4610-22-R-0001
About this file
This is a request for proposal for launch operations support contract services issued by the 30th Space Wing at Vandenberg Air Force Base. The RFP seeks proposals for launch operations support including engineering, analysis, processing, and launch services. Interested contractors must submit proposals by January 27, 2022. The North American Industry Classification System code for this opportunity is 561210 for facilities support services, with a small business size standard of $41.5 million. The RFP includes fifteen attachments outlining requirements such as the performance work statement and government furnished property, six Davis-Bacon wage determinations, collective bargaining agreements, and security specifications. Five additional documents provide templates for staffing plans, subcontractor consent, organizational conflict of interest mitigation, and proposal instructions.
View the file
Other files for this federal contract opportunity
Show all 50
Launch Operations Support Contract (LOSC) Request for Proposal (RFP) – FINAL has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Technical Data Dynamix 1444 Series Monitoring System Specifications Catalog Numbers 1444-DYN04-01RA, 1444-TSCX02-02RB, 1444-RELX00-04RB, 1444-AOFX00-04RB, 1444-TB-A, 1444-TB-B
The Dynamix™ series of intelligent I/O modules process, in real-time, critical parameters that are used in protecting industrial machinery from imminent failure, and in assessing the machines current and predicted health. The versatile 1444 series can be made an independent solution for serving condition monitoring data. The monitoring data can be sourced from simple motors, pumps, and fans or part of a Turbine Supervisory Instrumentation system. The Turbine Supervisory Instrumentation system serves diagnostic data while protecting high-speed turbo compressors, steam or gas turbines, and other critical rotating or reciprocating machines.
The 1444 series can perform its protection function entirely on its own by using its integral relays and can communicate machine status and condition data, including discrete fault indicating parameters to plant control and information management systems. As part of the Rockwell Automation Integrated Architecture® system, configuration and management of the Dynamix system is accomplished through a Logix controller,(1) which is linked via an EtherNet/IP industrial network.
Tight coupling of the Dynamix system with the Integrated Architecture system permits the application of other Integrated Architecture system components such as controllers, visualization products, other input and output products, and more.
This integration provides a seamless, easily-deployed and maintained system that can be tailored to the needs of each application that it serves.
(1) The Dynamix system performs its safety and protection function regardless of the availability of the controller.
The Dynamix series consists of just six core part numbers and various accessories for connectors and cables.
Additional Resources
These documents contain additional information concerning related products from Rockwell Automation.
You can view or download publications at http://www.rockwellautomation.com/literature. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
Table 1 - 1444 Series Catalog Numbers
Type Module Cat. No. Page
Measurement modules Dynamic Measurement Module 1444-DYN04-01RA 5
Speed modules Tachometer Signal Conditioner Expansion Module 1444-TSCX02-02RB 13
Relay modules Relay Expansion Module 1444-RELX00-04RB 15
Analog output modules 4…20mA Expansion Module 1444-AOFX00-04RB 16
Terminal bases Dynamic Measurement Module Terminal Base 1444-TB-A 18
Expansion Module Terminal Base 1444-TB-B 18
Table 2 - Removable Plug Connector Sets
Module Spring Connector Screw Connector Page
1444-DYN04-01RA 1444-DYN-RPC-SPR-01 1444-DYN-RPC-SCW-01 19
1444-TSCX02-02RB 1444-TSC-RPC-SPR-01 1444-TSC-RPC-SCW-01 19
1444-RELX00-04RB 1444-REL-RPC-SPR-01 1444-REL-RPC-SCW-01 19
1444-AOFX00-04RB 1444-AOF-RPC-SPR-01 1444-AOF-RPC-SCW-01 19
Terminal Base Spring Connector Screw Connector Page
1444-TB-A 1444-TBA-RPC-SPR-01 1444-TBA-RPC-SCW-01 19
1444-TB-B 1444-TBB-RPC-SPR-01 1444-TBB-RPC-SCW-01 19
Table 3 - 1444 Series Interconnect Cable Accessories
Cat. No. Description Page
1444-LBIC-04 Local Bus Interconnect Cable (qty 4) 19
1444-LBXC-0M3-01 Local Bus Extender Cable (0.3 m) 19
1444-LBXC-1M0-01 Local Bus Extender Cable (1.0 m) 19
Resource Description
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing a Rockwell Automation® industrial system.
Product Certifications website, http://www.rockwellautomation.com/rockwellautomation/certification/overview.page
Provides declarations of conformity, certificates, and other certification details.
2 Rockwell Automation Publication 1444-TD001A-EN-P - December 2014 http://literature.rockwellautomation.com/idc/groups/literature/documents/in/1770-in041_-en-p.pdf http://www.rockwellautomation.com/rockwellautomation/certification/overview.page http://www.rockwellautomation.com/rockwellautomation/certification/overview.page http://www.rockwellautomation.com/literature/
Dynamix 1444 Series Common
Dynamix 1444 series modules are designed to serve the condition monitoring requirements of rotating and reciprocating industrial machinery. The family includes the 1444-DYN04-01RA high performance, highly-configurable main module. The 1444-TSCX02-02RB modules provide tachometer signal conditioning. The 1444-RELX00-04RB relays, 1444-AOFX00-04RB analog outputs, and 1444-TB-A/B terminal bases are also included in the family. The modules are applied in combinations as necessary to the application.
All 1444 series modules and terminal bases share the following common hardware specifications.
API-670 Compliance
The 1444 series is designed in accordance with the relevant sections of the 5th Edition of the American Petroleum
Table 4 - 1444 Series Common Hardware Specifications
Attribute 1444-DYN04-01RA, 1444-TSCX02-02RB, 1444-RELX00-04RB, 1444-AOFX00-04RB, 1444-TB-A/B
Technical Specifications
Enclosure type rating None (open-style)
North American Temp Code T4
IEC Temp Code T4
Power
Voltage Input: 18…32V DC, max 5 A SELV/class 2 source
Conformal Coating
All printed circuit boards are conformal coated in accordance with IPC-A-610C and in compliance with:
• IPC-CC-830B
• UL508
Environmental Specifications
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-25…70 °C (-13…158 °F)
Temperature, surrounding air, max 70 °C (158 °F)
Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock):
-40…85 °C (-40…185 °F)
Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat):
5…95% noncondensing
Vibration Per IEC 600068-2-6 (Test Fc, Operating):
2 g @ 10…500 Hz
Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock):
15 g
Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock):
30 g
Emissions IEC 61000-6-4
ESD immunity
IEC 61000-4-2:
6 kV contact discharges 8 kV air discharges
Radiated RF immunity
IEC 61000-4-3:
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 1V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
Conducted RF immunity
IEC 61000-4-6:
10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Certifications(1) c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584.
UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada.
See UL File E194810.
CE European Union 2004/108/EC EMC Directive, compliant with:
• EN 61326-1; Meas./Control/Lab., Industrial
Requirements
• EN 61000-6-2; Industrial Immunity
• EN 61000-6-4; Industrial Emissions
• EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2006/95/EC LVD, compliant with:(2)
EN 61131-2; Programmable Controllers (Clause 11)
RCM EN 61000-6-4; Industrial Emissions
Ex European Union 94/9/EC ATEX Directive, compliant with:
• EN 60079-15; Potentially Explosive Atmospheres, Protection "n"
• EN 60079-0; General Requirements
• II 3 G Ex nA IIC T4 Gc
• II 3 G Ex nA nC IIC T4 Gc (only 1444-DYN04-01RA and 1444-RELX00-04RB)
• DEMKO14ATEX1365X
IECEx IECEx System, compliant with:
• IEC 60079-15; Potentially Explosive Atmospheres, Protection "n"
• IEC 60079-0; General Requirements
• II 3 G Ex nA IIC T4 Gc
• II 3 G Ex nA nC IIC T4 Gc (only 1444-DYN04-01RA and 1444-RELX00-04RB)
• IECEx UL 14.0082X
KC Korean Registration of Broadcasting and Communications Equipment, compliant with:
Article 58-2 of Radio Waves Act, Clause 3
(1) When product or packaging is marked. See the Product Certification link at http://www.rockwellautomation.com/ for Declarations of Conformity.
(2) Applies to only 1444-DYN04-01RA and 1444-RELX00-04RB modules.
Table 4 - 1444 Series Common Hardware Specifications
Attribute 1444-DYN04-01RA, 1444-TSCX02-02RB, 1444-RELX00-04RB, 1444-AOFX00-04RB, 1444-TB-A/B
Rockwell Automation Publication 1444-TD001A-EN-P - December 2014 3 http://www.rockwellautomation.com/
Institutes (API) standard 670,(1) ‘Machinery Protection Systems’.
Local Bus
The 1444 series family includes a power and communication bus that, similarly to the backplane of a rack-based system, connects a series of modules.(2) The Local Bus is implemented by using simple ribbon connectors that typically span adjacent modules.(3)
Insert and Remove Under Power
All 1444 series modules can be removed and replaced while power is applied to its terminal base(4), (5).
Mounting and Connections
DIN Rail
Terminal bases require DIN mounting by using 35 x 7.5 mm rail.
1444 series modules do not connect ground to the DIN rail, therefore coated DIN rail is acceptable.
Wiring Connectors
Field wiring landed to 1444 series modules and terminal bases are via 45°, front access, removable plug connectors with screw and spring-cage connectors available(6).
Each connector is keyed such that it can be inserted into the location on the module or terminal base that it serves.
Connectors are secured in place by quarter-turn screws.
(1) Whether a system is compliant is dependent on the components that are provided, the various optional elements of the standard that you require, and the configuration of the installed system.
(2) Any main module must be installed to the left of any expansion modules that it manages.
(3) A short ribbon cable, suitable for connecting adjacent modules, is included with each terminal base. See the Accessories, section of this publication for a description of available extended length cables.
Table 5 - Local Bus Function
Attribute Description
Power Passes power from each main module (1444-DYN04-01RA) to its expansion modules
Power is not passed between main modules
When redundant power supplies are connected to a main module, only the voted power source is distributed to its expansion modules.
TTL signals Dual independent TTL signals, with tachometer sensor status, are passed on the Local Bus
There can be only one tachometer expansion module on a local bus
The TTL signal can serve up to 6 main modules
Communication A digital network that is used between a main module and its expansion modules is implemented on the local bus
Communication does not link main modules
WARNING: If you insert or remove the module while backplane power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding.
WARNING: If you connect or disconnect wiring while the field-side power is on, an electrical arc can occur.
This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding.
(4) If a removed module includes an energized relay, the relay goes to its de-energized state.
(5) If Ethernet is daisy chained, one module to the next, and DLR is not used, removing a main module causes the loss of Ethernet communication to all ‘downstream’ main modules.
(6) A spring cage or screw clamp Removable Plug Connector set must be purchased for each module and terminal base ordered. See Table 2 for available catalog numbers.
4 Rockwell Automation Publication 1444-TD001A-EN-P - December 2014
Controller Independence
While the 1444 series is dependent on a Logix controller for its initial configuration, it is not dependent on the controller to perform its protection function. If communication with the controller is lost, the system continues to perform measurements, evaluate alarm conditions and, if necessary, actuate its relays. It also remains available to serve data to other hosts(1) that can remain accessible.
Nonvolatile Memory
After its initial configuration, a 1444 series Main Module maintains its configuration in nonvolatile memory. After any subsequent power cycle, the module loads its configuration from the nonvolatile memory and resumes its normal function. This process makes sure that even if the controller is not accessible after powerup that the monitor performs its function.
Dynamic Measurement Module
(1444-DYN04-01RA)
The Dynamix 1444 Series dynamic measurement module has four channel and is capable of general purpose monitoring.
The dynamic measurement module serves industrial machinery protection and condition monitoring applications. The module supports measurements of dynamic inputs such as vibration and pressure. The module supports measurements of and static inputs such as thrust, eccentricity, and rod drop. The module can be used for monitoring the following:
• Shaft vibration
• Casing vibration
• Pedestal vibration
• Shaft and rod position
• Casing expansion
• Other critical dynamic and position measurements on rotating and reciprocating machinery
To achieve this degree of adaptability, the module couples an extraordinarily flexible firmware and a powerful multi-processor hardware platform.
The 1444-DYN04-01RA module is designed specifically for integration with Allen-Bradley® Logix 5000™ controllers that are connected across an industrial Ethernet network.
This design makes the 1444 series unequaled in its ability to serve as a synergetic member of larger total facility control and information management systems.
Table 6 - Field Wiring Termination Requirements
Attribute Description
Conductor type Copper
Conductor/ insulation temperature rating, min
85 °C (185 °F)
Operating temperature, max (screw type only)
115 °C (239 °F)
Operating temperature, max (spring type only)
105 °C (221 °F)
Torque (screw type only)
0.22… 0.25 N•m (2…2.2 lb•in)
Stripping length 9 mm (0.35 in.)
Conductor cross-section solid or stranded
0.14…1.5 mm² (26…16 AWG)
Conductor cross-section stranded with ferrule without plastic sleeve
0.25…1.5 mm² (24…16 AWG)
Conductor cross-section stranded with ferrule with plastic sleeve
0.25…0.5 mm² (24…20 AWG)
Conductor cross section AWG/kcmil
0.08…1.5 mm² (28…16 AWG)
Conductor UL/cUL AWG (screw type only)
0.05…1.5 mm² (30…16 AWG)
Conductor UL/cUL AWG (spring type only)
0.08…1.5 mm² (28…16 AWG)
(1) Only the controller that ‘owns’ a module can change its configuration. Other processors such as personal computers, DCS computers, or other controllers, can query the module for data.
Rockwell Automation Publication 1444-TD001A-EN-P - December 2014 5
Hardware Specifications
Table 7 - 1444-DYN04-01RA H/W Specifications
Attribute Description
Channel Inputs (4)
Sensor types ICP accelerometers (CCS) Dynamic pressure transducers Dual sensors (acceleration + temperature) Eddy current probe systems (-24V DC) Self-powered sensors Voltage signals
Transducer positive power
Constant current: 4mA @ 24V
Voltage regulated: 24V/25 mA
Transducer negative power
Voltage regulated: -24V/25 mA
Voltage range ± 24V DC
Isolation Non-isolated, single-ended analog inputs. Sensor signal returns must be isolated from ground
Impedance >100 kΩ
Protection Reverse polarity
Transducer fault detection
Bias level high / low limits
Current threshold level monitoring, which is implemented in hardware for -24V supplied sensors. Provides the fastest, most reliable fault detection possible
A/D Converter
Conversion 24 bit
Measurement accuracy
± 0.1% full scale minimum (3 μV theoretical)
Dynamic range 80 dBfs (0.01% fs), 90 dBfs typical
Sample rate 2 Channels 93 kS/s
4 Channels 47 kS/s
Tachometer Inputs (2)
Terminal inputs TTL class with internal pull-up resistor (5V DC)
Local bus inputs Opto-isolated TTL input for signal and TX status
Detection threshold
Fixed (-2.5V DC)
Transducer status Only local bus inputs
Protection Reverse polarity
Digital Inputs (2)
Connection Terminal pins
Type TTL class
Power 32V DC, 15 mA max per output
Isolation Non-isolated
Application Trip inhibit/bypass Alarm/relay reset Alarm SPM/gate control 0, 1 Tachometer 0, 1 status
Digital Outputs (2)
Connection Terminal pins
Type Opto-isolated open-collector
Power 32V DC, 15 mA max per output
Application Module status Tachometer 0, 1 TTL Tachometer 0, 1 status Replicate digital input 0, 1 Transducer 0…3 Status Voted alarm 0…12 status
Buffered Outputs (4)
Connections Terminal pins
BNC
Protection Short circuit protected
Power ± 24V, 8 mA max per output
Relay (1)
Contact arrangement
Single pole double throw (SPDT) Change-over contact
Rating 250V AC/24V DC, 5A max @ 40 °C (104 °F), 2 A @ 70 °C (158 °F)
Indicators
Status indicators (16)
Power Module status Network status Processor status Processor operating state DSP status DSP operating state Channel status (4) Relay status Ethernet link status (2) Ethernet activity indicator (2)
Real-Time Clock
Synchronization IEEE-1588 standard ver. 2 CIP sync (ODVA)
Accuracy Max drift: 100 ms per year
Communication
Ethernet Connector (2): RJ45, shielded Speed: 10 MB/100 MB Modes: half/full duplex Operation: auto-switching - auto negotiation - auto mitigation
Communication protocol
ODVA compliant (conformance tested) EtherNet/IP industrial protocol
Supported connectivity protocols
Single Ethernet (IEEE 802.3) Device level ring (ODVA)
IP address Set by hardware switch on the terminal base
Set in configuration (retained in nonvolatile memory)
Concurrent acess Controller (owner)
Up to 3 (more) sessions
Power
Connections (2) Terminal pins
Current 411 mA @ 24V (546…319 mA @ 18…32V)
Consumption 11.5 W
Dissipation 9 W
Table 7 - 1444-DYN04-01RA H/W Specifications
Attribute Description 6 Rockwell Automation Publication 1444-TD001A-EN-P - December 2014
Functional Specifications
The capabilities of the 1444-DYN04-01RA module vary depending on configuration.
The selected module Personality defines the application of the channels and the available sample rates per channel, see Table 8.
The module can measure static values such as position from proportional (DC) voltages, but it is designed to make dynamic measurements. Dynamic measurements are typically of vibration but can also be of pressure, strain, or other signals.
The signal source (input) to dynamic measurements is selectable from up to five points in the signal processing path. Signal sources include the output of the analog to digital converter, before and after the low and high pass filters within the ‘primary’ signal processing path, and from the output of an entirely independent ‘alternate’ signal processing path, see Table 10.
Redundant power Two 18…32V DC, max 5 A SELV/class 2 power supply inputs
Higher voltage supply is applied to main and expansion modules
Power monitor The two power supply voltage levels are monitored. Status indicated via process operating status indicators and on controller input (I/O).
Isolation voltage 50V (continuous), basic insulation type between Ethernet, power, ground, and AUX bus 50V (continuous), basic insulation type between signal ports, power, ground, and AUX bus 250V (continuous), basic insulation type between relay ports and system No isolation between signal ports and Ethernet ports No isolation between individual signal ports or Ethernet ports Relay ports type tested at 1500V AC for 60 s All other ports type tested at 707V DC for 60 s
Environmental
EFT/B Immunity
IEC 61000-4-4:
±2 kV at 5 kHz on unshielded power ports ±2 kV at 5 kHz on shielded signal ports ±2 kV at 5 kHz on shielded Ethernet ports ±3 kV at 5 kHz on unshielded relay ports
Surge Transient Immunity
IEC 61000-4-5:
±1 kV line-line(DM) and ±2 kV line-earth(CM) on unshielded power and relay ports ±2 kV line-earth(CM) on shielded signal ports ±2 kV line-earth(CM) on shielded Ethernet ports
Terminal Base
Requires terminal base 1444-TB-A
Removable Plug Connector Sets
Module Spring 1444-DYN-RPC-SPR-01
Screw 1444-DYN-RPC-SCW-01
Terminal base Spring 1444-TBA-RPC-SPR-01
Screw 1444-TBA-RPC-SCW-01
Dimensions
Definition H: Height above DIN rail
W: Width along DIN rail
D: Depth across DIN rail
Without terminal base (H x W x D)
106 x 102 x 154 mm (4.17 x 4.02 x 6.06 in.)
With terminal base (H x W x D)
125 x 102 x 158 mm (4.92 x 4.02 x 6.22 in.)
Weight
Without terminal base
0.40 kg (0.88 lb)
With terminal base 0.58 kg (1.28 lb)
Wiring
Wiring category(1) 2 - on signal ports 2 - on power ports 2 - on communications ports 1 - on relay ports
Wire type Shielded on signal and Ethernet ports Unshielded on power and relay ports
(1) Use this Conductor Category information for planning conductor routing. See Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Table 7 - 1444-DYN04-01RA H/W Specifications
Attribute Description
Table 8 - Module Personalities
Real Time Description
4 dynamic (5 kHz) or static Channels sampled in pairs (0/1, 2/3) but configured individually as dynamic (up to 5 kHz Fmax), static, or off
4 dynamic (5 kHz) - dual path
Channels sampled and configured in pairs (0/1, 2/3). Configure pairs as dynamic (up to 5kHz Fmax), static, or off. Dual path internally connects channels 0,2 and 1,3
2 dynamic (20 kHz) + 2 static
Channels sampled and configured in pairs (0/1, 2/3). Configure channels 0/1 as dynamic (up to 20 kHz Fmax) or off, channels 2/3 as static or off
2 dynamic (40 kHz) Channels 0/1 sampled and configured as a pair. Configure channel pair as dynamic (up to 40 kHz Fmax) or off, or gSE or off.
Channels 2/3 are off
Table 9 - Supported Engineering Units
Signal Type Engineering Units
Acceleration m/s², inch/s², g, mm/s², mg, RPM/min
Velocity m/s, inch/s, mm/s
Displacement m, mm, micron, inch, mil
Spike energy gSE
Temperature °K, °C, °F
Voltage V, mV
Current A, mA
Power W, kW, MW, VA, kVA, VAR, kVAR, Pressure Pa, kPa, MPa, bar, mbar, psi
Frequency Hz, cpm, RPM
Flow l/min, cgm, US g/min, m3/min
Other EU Rockwell Automation Publication 1444-TD001A-EN-P - December 2014 7 http://literature.rockwellautomation.com/idc/groups/literature/documents/in/1770-in041_-en-p.pdf
Signal Conditioning Real-Time Measurements
Real-Time measurements are made on the Primary Path signal source data stream. How fast they update is dependent on the selected module personality, see Table 8.
Table 10 - Measurement Data Sources
Meas. Source Description
ADC out Signal out of the ADC
Pre filter After Fmax decimation
Mid filter After low pass filter
Post filter After high pass filter and integration
Alternate path Alternate signal path
Table 11 - 1444-DYN04-01RA Signal Conditioning
Attribute Description
Maximum frequency 4-Ch. protection: 5 kHz
2-Ch. protection: 20 kHz
Surveillance: 40 kHz
Low pass filter -3 dB corner 10 Hz to 5 kHz
-24, -60 dB/octave
Signal detection Peak to peak Peak
RMS
Calculated peak to peak Calculated peak
Primary Path Signal Conditioning
Sampling mode Asynchronous
Bandwidth FMAX * 4 Ch 9 Hz – 18.3 kHz
2 Ch 9 Hz – 36.6 kHz
* See (Table 8)
High pass filter -3 dB corner: 0.1 Hz to 1 kHz
-24, -60 dB/octave
Integration None, single or double
Alternate Path Signal Conditioning
Sampling mode Asynchronous
Synchronous
Asynchronous mode FMAX* 4 Ch 9 Hz…18.3 kHz
2 Ch 9 Hz…36.6 kHz
* See Table 8.
Synchronous mode Tachometer source: 0, 1
Pulses per rev: 4…128
Special Dynamic Signal Conditioning
Absolute shaft Per channel pair
Ch-0/2: displacement
Ch-1/3: acceleration or velocity
Relative mounting: 0°, 180° gSE 2 gSE channels max
Only 2-channel protection or surveillance modes
Overall, only TWF/FFT
HPF: 200, 500 Hz, 1, 2, 5 kHz
FFT FMAX: 100 Hz…5 kHz
Table 12 - Real-time Measurement Specifications
Personality Update Rate
Real time 40 ms
Attribute (#) Description
Overall (8) Number per channel: 2
Signal detection
Data source:
OA 0: post filter (fixed) OA 1: pre/mid filter (selectable)
Time constant
Tracking filters (16) Number per channel: 4
Data source: pre filter
Roll Off: -48 dB/octave
Per channel Signal detection
Integration: none, single, double
Revolutions (resolution)
Per filter Enable
Speed reference:
0 or 1
Order: 0.25…32x
Measure Magnitude
Phase (integer orders)
SMAX (2) Per channel pair
Not 1x (4) Number per channel: 1
Bias/gap (4) Number per channel: 1
Shaft absolute (2) Per channel pair gSE overall (2) Number per channel: 1
Table 11 - 1444-DYN04-01RA Signal Conditioning
Attribute Description 8 Rockwell Automation Publication 1444-TD001A-EN-P - December 2014
The module supports common DC and rod drop measurements. When specified, these measurements are also Real-Time measures.
Continuous Measurements
Continuous measurements include the complex time waveforms and FFTs, and the FFT band values. Because time waveforms are captured with ‘maximum overlap’, they can be updated rapidly. However, as these measures are second in priority to any defined real-time measurements, how fast they update is dependent on configuration.
Two complex data measurements can be defined, each with its own data source and TWF/FFT attribute definitions.
One continuous complex data measurement is applied uniquely to the FFT Band measurements. As the band values are the only use of these complex data, the source TWF / FFT are not otherwise available.
The second continuous data measurement is for the time waveform and FFT that are written to the Alarm, Trend (Trend and Alarm Capture), and dynamic measurement buffers. These measurements are also the TWFs and FFTs that are served to a remote host when the ‘current’ complex measurements are requested.
Demand Measurements
Demand measurements are unscheduled data requests from the controller or computers. These data are typically measured from another source, at another resolution, or with another Fmax from the continuous measures.
Because for protection applications the real time and continuous measurements must meet minimum required update rates, Demand data is executed as a background process, as time is available. Therefore how fast Demand
Table 13 - Static (DC) Measurements
Attribute Description
Measurement type DC measurement
Rod drop
DC Measurements
Measurement types Proportional voltage
Eccentricity
Position Normal (thrust)
Radial cancel (ramp) differential expansion
Head to head (complimentary) differential expansion
Rod Drop Measurement
Trigger source Speed reference: 0 or 1
Table 14 - Continuous FFT Band Measurements
Personality Update Rate
Data source Selectable
Real time 100 ms (typical)
Attribute Description
FFT (4) Number of lines: 1,600
Averaging: exponential
Number of averages(1): 1, 2, 3, 6, 12, 23, 45, 89 or 178
Windows: none, flat top, hamming, hanning
FFT bands (32) Number per channel: 8
Measurement: OA, max peak amp, max peak Hz
Domain: Hz, orders
Order domain speed ref: 0, 1
(1) If the Time Waveform data source is Alternate Path, and the Alternate Path processing mode is Synchronous, averaging is performed in the time domain.
Table 15 - Complex Measurement Specification
Attribute Description
Data format 32-bit float, 16-bit or 8-bit scaled integer(1)
(1) Smaller data sizes lets memory hold a larger number of measurements, but at reduced precision.
Time waveform (4) Number per channel: 1
Block size: 256…8,192
Overlap: continuous maximum overlap
Data source: selectable
Asynchronous
FFT (4) Number of lines: 100…1,600
Averaging: exponential
Number of averages: 1, 2, 3, 6, 12, 23, 45, 89 or 178
Windows: none, flat top, hamming, hanning gSE FFT (2) Number per channel: 1
Number of lines: 100…1,600
Averaging: exponential
Number of averages: 1, 2, 3, 6, 12, 23, 45, 89 or 178
Table 14 - Continuous FFT Band Measurements
Personality Update Rate Rockwell Automation Publication 1444-TD001A-EN-P - December 2014 9 data can be serviced is dependent on module configuration and the modules activity when the request is made.
Speed Measurements
The 1444-DYN04-01RA module includes two speed inputs. The source of the speed measures can be a TTL signal or values that are passed to the module on its Input Table.
The speed values are applied to measurements, not channels. The measurements that are made on signals that are applied to any channel can be processed by using speed values.(1)
Alarms and Relays
The module offers two types of alarms, measurement and voted alarms. Relays are associated with voted alarms.
Measurement Alarms
Measurement alarms provide for the customary threshold limits that are applied to selected measurements.
Alarm threshold limits can be entered into the configuration, normal mode, or can be read from Controller I/O, profile mode. ‘Normal’ mode permits the usual static limits. Profile mode lets the controller determine and send to the module the limit for any given machine state, such as an instance of an alarm ‘profile’ to be applied during a process cycle.
Table 16 - Demand Measurement Specifications
Personality Update Rate
Real time 500 ms (typical)
Multiplexed Configuration dependent
Attribute Description
Time waveform Block size: 256…65,536
Sample rate: ≤Fmax
Data source: selectable
FMAXSP: Fmax for the signal path of the selected data source
(1) Phase measurements are only valid when the speed used is from a TTL source.
Table 17 - Speed Measurement Specifications
Attribute (#) Description
Speed (2) Number per module: 2
Source: selectable per speed
Local bus:
TTL
Transducer status
Terminal pins: TTL
Input table:
RPM
Transducer status
Speed maximum (2) 1 per speed measurement
Maximum speed since reset
Reset via controller I/O
Speed acceleration (2) 1 per speed measurement
Units: RPM/min
Update rate: 1 / second
Mode Normal 2 independent speeds
Redundant Speed 0 = Speed 1 when tach 0 in fault
Table 18 - Measurement Alarms
Attribute Description
Number 24
Input parameter Any real time or discrete continuous measurement
Alarm form Over/under threshold
Inside/outside window
Dead band 0…20% of limit
Transducer state consideration
OK required
Not OK forces alarm
OK status not considered
Processing mode Normal Static limits that are applied
Profile Limits that are read from controller I/O
Delay times Separate delay times for alert and danger alarms
0.10…60.0 s
Sustain time 1.0 s (fixed)
Table 17 - Speed Measurement Specifications
Attribute (#) Description 10 Rockwell Automation Publication 1444-TD001A-EN-P - December 2014
Voted Alarms
Voted alarms provide a voted logic solution that is based on the status of up to four measurement alarms.
Relays
Relays are enabled and mapped to a voted alarm and selected faults. All logic that is associated with relay actuation on alarm is included in the Voted Alarm definition.(1) Logic that is associated with relay activation on fault is local to the relay.
Event Management
The 1444 series manages events as follows:
• Optimizes behavior
• Uses alarm gating or adaptive limit multipliers
• Provides tools for recording the occurrence of events and data from an event
Event Log
The module includes a rolling (first-in, first out) event log, held in nonvolatile memory, that is in compliance with
API-670.
Set point multiplier Range: 0.1…100x
Multiply the threshold limits by this value when invoked. Can be:
Static Enabled by controller I/O or manual switch
Adaptive Up to 5 multipliers that are defined for ranges of any 3rd parameter (typically speed)
Table 19 - Voted Alarms
Attribute Description
Number 13
Input condition Alert
Danger
Transducer fault
Latching Non-latching, resets when condition clears
Latching, after condition clears, resets upon command via controller I/O
Fail safe If assigned to a relay, when in alarm the relay coil is de-energized
Alarm logic 1oo1, 1oo2, 2oo2, 1oo3, 2oo3, 3oo3, 1oo4, 2oo4, 3oo4, 4oo4, 1oo2 AND 1oo2. 2oo2 OR 2oo2,1oo2 AND 2oo2, 2oo2 AND 1oo2
Logic inputs 1…4 measurement alarms
SPM timer Number of seconds the SPM is applied after SPM signal is reset.
From 0…65.5 s in 0.1 s increments
SPM control source Controller I/O SPM control bit 0 or 1/digital input 0 or 1
Speed gating control Speed reference: 0, 1
Condition (>, <, <>, ><)
Speed limits (low, high)
I/O gating control Controller output (I/O)
Select one of 2 control bits
Table 18 - Measurement Alarms
Attribute Description
(1) Expansion module relays can also be configured to act on fault (page 19).
Table 20 - Relay Logic Attributes
Attribute Description
Number 13
Enable Enable to assign the relay to a voted alarm
Voted alarm Assign to any enabled voted alarm (0…12)
Faults Main module fault Main module tachometer fault Expansion module fault Ethernet network fault Expansion bus fault
If associated to a voted alarm that is configured fail safe, main module fault is required
Latching/non-latching
Table 21 - Event Log Attributes
Attribute Description
Event types • System
• Alarm
• Buffer
Conditions • 35 logged conditions
• Categorized by event type
Number of entries • 768 total records
• 256 records per event type
Time stamp resolution 0.1 ms Rockwell Automation Publication 1444-TD001A-EN-P - December 2014 11
Trend and Alarm Capture
Comprised of static and dynamic data, the Trend facility provides a source for real time/recent history/high density data without the need for continuous updates to an external data historian.
The Alarm facility provides for the capture of data immediately before and after an alarm or receipt of a trigger from the Controller signals an event. The Alarm facility includes a copy of the Trend buffers static and dynamic data. The static and dynamic data includes some samples after the trigger, plus a second set of static data that was captured at the maximum rate.
Time Synchronization
Time synchronization on EtherNet/IP is implemented by using CIP Sync. CIP Sync is a technology that is based on and fully compliant with the IEEE-1588 Standard Version 2 for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems. With the
CIP Sync technology, synchronization between 1444 series Modules and networked Controllers down to 100 nanoseconds can be achieved.
Supported Network Topologies
The 1444 series offers two alternatives to the network solution applied. These alternatives include the common single wire Ethernet networks and Device Level Ring networks for when a more fault-tolerant topology is required.
Single Ethernet
By using single Ethernet, as defined by IEEE 802.3, modules are connected in series on a common network. In this architecture, typically, the network is routed through adjacent modules by using one RJ-45 connector as its input and the second connector as an output.
Device Level Ring
Device Level Ring (DLR) is a network topology that lets devices be connected in series, one-to-the-next, and back to the beginning, which forms a ring. Ring topologies offer a far simpler fault-tolerant network design that requires less cabling and can be installed at lower cost, while still providing a resilient, responsive solution.
Unlike typical ring solutions, DLR is deployed at the end devices, instead of the switches. So a DLR enabled device can connect directly to neighboring nodes. A ring topology at the device level greatly reduces the number of wires on the network, and the number of needed industrial Ethernet switches.
Fault Management
On detection of a fault, a Dynamix 1444-DYN04-01RA module provides indication via its status indicators, and communicates the status via Controller I/O. Additionally, the single onboard relay can be configured to actuate based on any of the detected faults, see Table 23.
Table 22 - Trend and Alarm Capture Attributes
Attribute Description
Enable Enable static data capture
Enable dynamic data capture
Record content Discrete data Any number of measurements
Dynamic data TWF and FFT per channel
Trend Buffer
Static data Number of records: 640
Sample rate: N x 100 ms
Dynamic data Number of records: 64
Sample rate(1): N x 100 ms
(1) How fast dynamic data can be written to Trend and Alarm buffers is dependent on the total module configuration. While a 1 second rate can be assured, a 100 millisecond rate cannot be possible.
Alarm Buffer
Trigger source Controller output (I/O) control bit Any voted alarm (alert condition) Any voted alarm (danger) Any voted alarm (TX Fault)
Saved trend buffer 640 static records Includes N% records sampled post trigger
64 dynamic records Includes N% records sampled post trigger
High-resolution samples 320 static records
Sampled rate: 100 ms 12 Rockwell Automation Publication 1444-TD001A-EN-P - December 2014
Controller I/O
The Dynamix 1444-DYN04-01RA module provides the following data in its controller input and output assemblies.
Input
The content of the input assembly is configurable, in Module Definition. At a minimum, the assembly consists of a fixed record of status information.
Additionally the Input Assembly can contain any number of measured values. These values include the real-time measurements that are listed in Table 12, the DC measurements in Table 13, and the continuous measurements that are listed in Table 14.
Output
The content of the Output assembly is configurable, in Module Definition. The assembly includes various control bits, plus, when specified, speed values and alarm limits.
Tachometer Signal Conditioner Expansion Module 1444-TSCX042-02RB
The Dynamix 1444 series tachometer signal conditioner expansion module is a two-channel monitor that converts the signal from common speed sensing transducers into a once-per-rev TTL class signal suitable for use by 1444- DYN04-01RA dynamic measurement modules.
The 1444-TSCX02-02RB module is designed for use with a Dynamic Measurement module, which acts as its host, serving power and managing the configuration of the modules.
Table 23 - Main Module Fault Management Specification
Attribute Description
Expansion bus link time out 100 ms (fixed)
Fault actions
Indication Flash status indicator (Table 7)
Controller I/O Status bits on controller input table
Relay action Select fault on any of(1)
(1) If no fault action is defined for the relay of the main module, and the voted alarm that is associated with the relay is not configured Fail Safe, the relay is held in its current position until the fault condition clears.
Module*
Expansion module
Ethernet
Expansion bus
Latching/non-latching on fault
*Actuates on module fault if associated voted alarm configured fail safe
Table 24 - Controller Input Status Information
Control Bits
Aux processor DSP processor
Trend alarm Transducer
Alarm status Channel setup
Relay status Expansion module
Table 25 - Controller Output
Control Bits
Trip inhibit Alarm buffer trigger
Set point multiplier enable Alarm buffer reset
Alarm reset Alarm gate control
Data
Speed (2) Alarm limits (16)
Table 26 - 1444-TSCX02-02RB Hardware Specifications
Attribute Description
Channel Inputs (2)
Sensor types Voltage signals Eddy current probe systems
TTL
NPN proximity switch PNP proximity switch Self-generating magnetic sensors
Transducer positive power Voltage regulated: 24V/25 mA
Transducer negative power Voltage regulated: -24V/25 mA
Voltage range ± 24V
Isolation Non-isolated, single-ended analog inputs. Connected sensors shall have their signal return isolated from ground Rockwell Automation Publication 1444-TD001A-EN-P - December 2014 13
Functional Specifications
Host Module Dependence
The Tachometer Signal Conditioner commonly serves speed signals to main modules other than its host. So, unlike other expansion modules, and except for configuration services, the 1444-TSCX02-02RB operates independently of its host module. Therefore, once configured, the Tachometer Signal Conditioner continuously serves TTL speed signals regardless of the state or availability of its host module or Local Bus.
Fault Management
On failure of self-test or on communication link failure, the Tachometer Signal Conditioner module notifies its host
Impedance >100 kΩ
Protection Reverse polarity
A/D converter 24 bit
Measurement accuracy ± 3 degrees of speed input for 1/rev up to 20 kHz
Measurement error 0.0167…4 Hz: ± 0.0033 Hz 4…200 Hz: ± 0.033 Hz 200…340 Hz: ± 0.083 Hz 340…2000 Hz: ± 0.333 Hz 2000…6000 Hz: ± 1.0 Hz 6000…20,000 Hz: ± 2.67 Hz
1…240 RPM: ± 0.2 RPM
240…12k RPM: ±2.0 RPM 12k…20.4k RPM: ±5.0 RPM 20.4k…120k RPM: ±20 RPM 120k…360k RPM: ±60 RPM 360k…1,200k RPM: ±160 RPM
Raw Buffered Outputs (2)
Connections BNC
Protection Short circuit protected
Voltage ± 20V
Conditioned Buffered Outputs (4)
Connections Terminal pins
Signal, 1/rev TTL (2)
Signal, N/rev TTL (2)
Power 5V DC, 35 mA max per output
Local Bus Outputs (2)
Connection Integral, via ribbon connector
Type Opto-isolated open-collector
Signal TTL speed (once-per-rev)
Tach channel status
Capacity Can serve 6 main modules (1444-DYN04-01RA) (minimum)
Power 5V DC, 5 mA max per output
Indicators
Status indicators (4) Power Channel status (2) Local bus status
Power
Current 128 mA @ 24V (174…104 mA @ 18…32V)
Consumption 4 W
Dissipation 3 W
Isolation 50V (continuous), basic insulation type between signal ports and AUX bus.
No isolation between individual signal ports.
Type Tested at 707V DC for 60 s.
Environmental
EFT/B immunity
IEC 61000-4-4:
±2 kV at 5 kHz on shielded signal ports
Surge transient immunity
IEC 61000-4-5:
±2 kV line-earth(CM) on shielded signal ports
Table 26 - 1444-TSCX02-02RB Hardware Specifications
Attribute Description
Terminal Base
Requires terminal base 1444-TB-B
Removable Plug Connector Sets
Module Spring 1444-TSC-RPC-SPR-01
Screw 1444-TSC-RPC-SCW-01
Terminal base Spring 1444-TBB-RPC-SPR-01
Screw 1444-TBB-RPC-SCW-01
Dimensions
Definition H: height above DIN rail
W: width along DIN rail
D: depth across DIN rail
Without terminal base (H x W x D)
65 x 54 x 154 mm (2.56 x 2.13 x 6.06 in.)
With terminal base (H x W x D)
96 x 54 x 158 mm (3.78 x 2.13 x 6.22 in.)
Weight
Without terminal base 0.16 kg (0.35 lb)
With terminal base 0.26 kg (0.57 lb)
Wiring
Wiring category(1),(2) 2 - on all ports
Wire type Shielded on signal ports
(1) Use this Conductor Category information for planning conductor routing. See Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
(2) Use this Conductor Category information for planning conductor routing as described in the appropriate System Level Installation Manual.
Table 26 - 1444-TSCX02-02RB Hardware Specifications
Attribute Description 14 Rockwell Automation Publication 1444-TD001A-EN-P - December 2014 module, if possible, and signals the condition via status indicators.
Relay Expansion Module
1444-RELX00-04RB
The Dynamix 1444 series relay expansion module is a four-relay module that serves to add relays to its host module.
The 1444-RELX00-04RB Relay Expansion Module is designed for use with a Dynamic Measurement module that acts as its host, serving power and managing the modules configuration.
Functional Specifications
Host Module Dependence
The Relay Expansion module is designed to act as an extension of its host module. The operation of the 1444- RELX00-04RB module is dependent on the availability of its host.
A handshake communiqué between the relay expansion module and its host are executed continuously to verify communication and each modules operation. Failure of the heartbeat constitutes a Link Failure condition on the relay module and a Module Fault on the main module.
Table 27 - TSC Module Functional Specification
Attribute Description
Communication link time out 1 second (fixed)
Fault Actions
Module or link Flash module status indicator
Table 28 - 1444-RELX00-04RB Hardware Specifications
Attribute Description
Relay (4)
Contact arrangement Single pole double throw (SPDT) change-over contact
Rating 250V AC/24V DC, 5 A max @ 40 °C (104 °F), 2 A @ 70 °C (158 °F)
Indicators
Status indicators (6) Power Relay status (4) Local bus status
Power
Current 56 mA @ 24V (73…48 mA @ 18…32V)
Consumption 1.6 W
Dissipation 2.3 W
Isolation voltage 250V (continuous), basic insulation type between relay ports and system Type tested at 1500V AC for 60 s
Environmental
EFT/B immunity
IEC 61000-4-4:
±3 kV at 5 kHz on unshielded relay ports
Surge transient immunity
IEC 61000-4-5:
±1 kV line-line(DM) and ±2 kV line-earth(CM) on unshielded relay ports
Terminal Base
Requires terminal base 1444-TB-B
Removable Plug Connector Sets
Module Spring 1444-REL-RPC-SPR-01
Screw 1444-REL-RPC-SCW-01
Terminal base Spring 1444-TBB-RPC-SPR-01
Screw 1444-TBB-RPC-SCW-01
Dimensions
Definition H: height above DIN rail
W: width along DIN rail
D: depth across DIN rail
Without terminal base (H x W x D)
65 x 54 x 154 mm (2.56 x 2.13 x 6.06 in.)
With terminal base (H x W x D)
96 x 54 x 158 mm (3.78 x 2.13 x 6.22 in.)
Weight
Without terminal base 0.18 kg (0.40 lb)
With terminal base 0.28 kg (0.62 lb)
Wiring
Wiring category(1),(2) 1 - on relay ports
Wire type Unshielded on relay ports
(1) Use this Conductor Category information for planning conductor routing. See Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
(2) Use this Conductor Category information for planning conductor routing as described in the appropriate System Level Installation Manual.
Table 28 - 1444-RELX00-04RB Hardware Specifications
Attribute Description Rockwell Automation Publication 1444-TD001A-EN-P - December 2014 15
Double-Pole Relays
When API-670 compliance or other applications require use of double-pole, double-throw (DPDT) relays, two expansion module relays can be paired.
Fault Management
If a Relay Expansion module fails self-tests (module fault) or detects a Link Failure, it actuates any relays that are configured as ‘Fail Safe’ in the referenced Voted Alarm definition and any relays that are configured to actuate on Expansion Bus fault.
Upon re-establishing communication to a relay module, a host module verifies the position of all relays, and commands each to be repositioned based on current alarm status and latching definition.
Analog Output Expansion Module
1444-AOFX00-04RB
The Dynamix 1444 series Analog Output Expansion Module is a four-channel module that outputs 4…20mA analog signals that are proportional to measured values passed to it by the modules host module.
The 1444-AOFX00-04RB Analog Output Expansion module is designed for use with a Dynamic Measurement module, which acts as its host, serving power and managing the modules configuration.
Hardware Specifications
Table 29 - Main Module Fault Management Specifications
Attribute Description
Communication link time out 100 ms (fixed)
Fault Actions
Indication Flash status indicator (Table 27)
Host notification Local bus status indication
Relay action Select fault on any of (1):
(1) If no fault action is defined for the relay, and the voted alarm that is associated with the relay is not configured Fail Safe, the relay is held in its current position until the fault condition clears and the main module commands it otherwise.
Module*
Expansion bus
Latching/non-latching
* Actuates on module fault if associated voted alarm configured fail safe
Table 30 - 1444-AOFX00-04RB Hardware Specifications
Attribute Description
Channels (4)
Current output 20 mA max per output
Protection Insensitive to polarity
Accuracy ± 0.1% full scale
Not OK output Configurable: force low (2.9 mA), force high (>20 mA), hold current level
Indicators
Status indicators (6) Power Channel status (4) Local bus status
Power
Current 18 mA @ 24V (22…8 mA @ 18…32V)
Consumption 0.76 W
Dissipation 3.6 W
Isolation voltage 50V (continuous), basic insulation type between signal ports and AUX bus.
No isolation between individual signal ports.
Type tested at 707V DC for 60 s
Environmental
EFT/B immunity
IEC 61000-4-4:
±2 kV at 5 kHz on shielded signal ports
Surge transient immunity
IEC 61000-4-5:
±2 kV line-earth(CM) on shielded signal ports
Terminal Base
Requires terminal base 1444-TB-B
Removable Plug Connector Sets
Module Spring 1444-AOF-RPC-SPR-01
Screw 1444-AOF-RPC-SCW-01 16 Rockwell Automation Publication 1444-TD001A-EN-P - December 2014
Functional Specification
The Analog Output Expansion module is designed to act as an extension of its host module. So the operation of the 1444-AOFX00-04RB module is dependent on the availability of its host.
Fault Management
On failure of self-test or on communication link failure, if possible, the 4…20 mA Output module notifies its host module, signals the condition via status indicators and drives its outputs as specified by configuration, see Table 31.
Terminal Bases
Each Dynamix module is installed in a terminal base that, when linked together, serve as the backplane of a 1444 series system.
Besides providing connections for common or ‘dirty’ wiring, the terminal bases provide two key capabilities for the system.
Addressing
The terminal base of the main module, the 1444-TB-A, includes a switch that is used to set the last octet of the IP address for the installed module. The address can be changed in firmware and held in nonvolatile memory. The terminal base switch provides a portable, physical relationship that makes sure that modules installed are at the address set on the base rather than whatever can be in the memory of the module.
The expansion modules terminal base, the 1444-TB-B, also includes an address switch. However, in this case the switch is only used when a relay module is installed. In that case, the relay module must be set as 0, 1, or 2. Addressing for the Tachometer Signal Conditioner expansion module and the Analog Output expansion module is automatic so does not use the switch.
Local Bus
Each terminal base includes the circuitry and connectors necessary to extend the local bus. A ribbon cable is included that is of a length suitable for connecting two adjacent terminal bases.(1)
The local bus is not interrupted when a module is removed.
Removal or failure of any module does not affect tachometer signals, power, and local bus communication.
Terminal base Spring 1444-TBB-RPC-SPR-01
Screw 1444-TBB-RPC-SCW-01
Dimensions
Definition H: height above DIN rail
W: width along DIN rail
D: depth across DIN rail
Without terminal base (H x W x D)
65 x 54 x 154 mm (2.56 x 2.13 x 6.06 in.)
With terminal base (H x W x D)
96 x 54 x 158 mm (3.78 x 2.13 x 6.22 in.)
Weight
Without terminal base 0.14 kg (0.31 lb)
With terminal base 0.24 kg (0.53 lb)
Wiring
Wiring category(1),(2) 2 - on signal ports
Wire type Shielded on all signal ports
(1) Use this Conductor Category information for planning conductor routing. See Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
(2) Use this Conductor Category information for planning conductor routing as described in the appropriate System Level Installation Manual
Table 31 - Analog Output Module Functional Specification
Attribute Description
Communication time out 1 second (fixed)
Fault Actions
Indication Flash module status indicator
Output behavior on fault options Hold current value
Force low (<4 mA)
Force high (>20 mA)
Table 30 - 1444-AOFX00-04RB Hardware Specifications
Attribute Description
(1) Longer cables are available for use when jumping modules on adjacent DIN rails or when locating modules in other areas of a cabinet.
Rockwell Automation Publication 1444-TD001A-EN-P - December 2014 17
Terminal Base 1444-TB-A
Terminal Base 1444-TB-B
All…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .