TECH LIBRARY 1 SVPP Supplier Manuals Axiomatic corrected current-converter.pdf
PDF 53 KB Posted
- Attached to
- Launch Operations Support Contract (LOSC) Request for Proposal (RFP) – FINAL Federal contract opportunity
- Solicitation number
- FA4610-22-R-0001
About this file
This Request for Proposal (RFP) solicits offers for launch operations support services at Vandenberg Air Force Base in California. The RFP seeks to award an indefinite delivery/indefinite quantity contract to provide mission planning, processing, launch, and range support for Department of Defense and National Aeronautics and Space Administration (NASA) missions. Services include payload processing, launch vehicle processing, mission integration, range safety, and emergency response. The period of performance is a one-year base period and four one-year options. Proposals are due by January 27, 2022 and the contract is anticipated to be awarded by the 30th Space Wing. The North American Industry Classification System code for this effort is 561210 and the size standard for small businesses is $41.5 million.
View the file
Other files for this federal contract opportunity
Show all 50
Launch Operations Support Contract (LOSC) Request for Proposal (RFP) – FINAL has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Axiomatic Technologies Corporation 5915 Wallace Street, Mississauga, Ontario Canada L4Z 1Z8
TEL: 1 (905) 602-9270 x225 FAX: 1 (905) 602-9279 E-mail: sales@axiomatic.com www.axiomatic.com
TECHNICAL DATASHEET #TD2300AX
4-20 mA to Current Converter P/N: IC-DR-XX and AX130300
Where xx = 11 (0-200 mA output) 12 (20 – 160 mA output)
14 (0-50 mA output) 18 (40-160 mA output) 20 (0-100 mA output) 24 (0-160 mA output)
25 (20-200 mA output) AX130300 (5-195 mA output)
Description: The Current Converter accepts a 24VDC power supply (nominal) and a 4-20mA input signal converting it to a current output. Various outputs are available, including 0-200 mA, 20-200 mA, 5-195 mA, 0-100 mA, 20-160 mA, 40- 160 mA, 0-160 mA or 0-50 mA. Span and zero is user adjustable. A diagnostic LED indicates operational status, glowing green when the load, input signal and power supply are connected. The load should be floating, isolated from ground. The circuit board is conformal coated and the unit is available in a 35 mm DIN rail mount housing.
Application:
Industrial automation Power generation controls
Technical Specifications:
Typical at nominal input voltage and 25 degrees C unless otherwise specified
Ordering Part Number: IC-DR-xx 4-20 mA to Current Converter Where xx = Output current default setting xx = 11 (0-200mA output) xx = 12 (20-160mA output) xx = 14 (0-50 mA output) xx = 18 (40-160 mA output) xx = 20 (0-100 mA output) xx = 24 (0-160 mA output) xx = 25 (20-200 mA output) AX130300: 4-20 mA input, 5-195 mA output
Input Specifications:
Current Input 4-20mA Input Impedance 50 Ohms +/- 1%
TD2300AX 2
Output Specifications:
Current Output Factory settings +/- 2mA:
IC-DR-11 = 0-200mA IC-DR-12 = 20-160 mA IC-DR-14 = 0-50 mA IC-DR-18 = 40-160 mA IC-DR-20 = 0-100 mA IC-DR-24 = 0-160 mA IC-DR-25 = 20-200 mA AX130300 = 5-195 mA (Other current output ranges are available on request.)
Connect output to the output positive terminal and not to GND.
Output Impedance <40 MOhm Response Time <5 mSec.
Non-linearity <0.1% without adjustments performed General Specifications:
Power Supply 24Vdc nominal (15-45Vdc operating range)
Transient protection is provided.
Power Consumption 550 milliwatts
All measurements taken at 24VDC, full output current (max.).
Reverse Polarity Protection Provided Operating Conditions -40 to 85 degrees C (-40 to 185 degrees F) Electrical Connection Screw terminals accept 14-24 AWG wire Enable (enables output through closing a mechanical relay contact)
To enable operation, externally short terminals 1 and 3.
Packaging and Dimensions (W x H x D)
DR12, Polycarbonate DIN rail mount (75 x 98.5 x 22.5 mm or 2.95 x 3.88 x 0.89 inches) for high profile DIN rail (35 mm)
Protection PCB conformal coated IP40 rated housing, Terminals rated at IP20
Weight 0.25 lb. (0.11 kg)
Adjustments: Multi-turn trim pots (10 turns) Zero CW = increasing
Apply 4mA input current and adjust the Zero trimpot to desired minimum output current. Refer to the chart below.
Factory settings are listed below.
Span CW = increasing Apply 20mA input current and adjust the Span trimpot to desired maximum current output. Refer to the chart below.
Factory settings are listed below.
CW = clockwise, CCW = counter clockwise
Default Current Outputs and Adjustment Ranges:
MODELS IOUT MIN RANGE IOUT MAX RANGE DEFAULT DEFAULT
P/N MIN [mA] MAX [mA] MIN [mA] MAX [mA] MIN [+/-2 mA] MAX [+/-2 mA]
IC-DR-11 0 25 155 220 0 200
IC-DR-12 6 29 116 171 20 160
IC-DR-14 0 5 38 63 0 50
IC-DR-18 0.14 43.46 143 172 40 160
IC-DR-20 0 12 69 105 0 100
IC-DR-24 0.14 43.46 143 172 0 160
IC-DR-25 0 25 155 220 20 200
AX130300 0 25 155 220 15 195
TD2300AX 3
Specifications are indicative and subject to change. Actual performance will vary depending on the application and operating conditions. Users should satisfy themselves that the product is suitable for use in the intended application. All our products carry a limited warranty against defects in material and workmanship. Please refer to our Warranty, Application Approvals/Limitations and Return Materials Process as described on www.axiomatic.com/service.html.
Form: TD2300AX-07/29/15