Submittal_List_-_Comfort_Station.pdf
PDF 89 KB Posted
- Attached to
- CUVA - Comfort Station Construction Federal contract opportunity
- Solicitation number
- 140P6421R0018
About this file
This document provides details for a federal solicitation seeking construction services. The National Park Service intends to issue a Request for Proposal for renovations and upgrades to an existing comfort station at Cuyahoga Valley National Park in Brecksville, Ohio. Work includes converting a wood vault toilet into a temperature-controlled flush toilet system with potable water and septic tank/drain field, and constructing a new water main. The project magnitude is estimated between $800,000 to $2,000,000. This will be a firm-fixed price contract subject to Construction Wage Rate Requirements for Summit County, Ohio. Evaluation factors are technical approach, past performance, and price. The NAICS code is 236220 for commercial and institutional building construction with a small business size standard of $39.5 million. The project is set aside 100% for small businesses. Offerors must have a DUNS number and be registered in SAM.gov to be eligible for award. The point of contact for the solicitation is Craig D Bryant at the National Park Service Midwest Region.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Site_Visit_Sign-in_Sheet_0001.pdf | ||
| Product_Specs_for_Approval__2_0001.pdf | ||
| Sol_140P6421R0018_Amd_0001.pdf | ||
| Product_Specs_for_Approval__1_0001.pdf | ||
| Questions_and_Answers_0001.pdf | ||
| Specifications_-_Comfort_Station.pdf | ||
| Drawings.pdf | ||
| Sol_140P6421R0018.pdf | ||
| Notice_to_Contractors.pdf | ||
| Technical_Questionnaire.pdf | ||
| Technical_Questionnaire.docx | DOCX document | |
| Past_Performance_Questionnaire.pdf | ||
| Bid_Schedule_-_Comfort_Station.xlsx | XLSX spreadsheet | |
| Past_Performance_Questionnaire.docx | DOCX document | |
| Wage_Determination_-_Summit_County_OH.pdf | ||
| Updated_-_COVID-19_Mask_Policy.pdf | ||
| Bid_Schedule_-_Comfort_Station.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
ER
T.
/L
A B
T
ES
T
R
EP
O R
T/ C
A
LC
O
R P
LA
N
M fg
. D A
TA
IN
ST
R U
C
TI
O N
S
SH
O
P D
R A
W
IN
G
SA
M
PL
E
M fg
. D A
TA
IN
ST
R U
C
TI
O N
S
01 31 00 1.3 Preconstruction Conference info required x
01 32 16 1.3 Construction Schedule x
01 40 00 1.4 Quality Requirements
Quality Control Plan x
Qualification Data x
Contractor's Quality Control Daily Reports x
Test Reports x
Permits, Licenses, and Certificates x
01 74 19 1.4 Waste Management Plan x
04 20 00 1.4 Unit Masonry x x
06 19 00 1.3 Prefabricated Wood Trusses and Joists x x
07 20 00 1.3 Building Insulation x
07 60 00 1.3 Flashing and Sheet Metal Standing Seam Roof Panel System x x x
08 11 13 Metal Doors and Frames x
08 71 00 1.5 Hardware and Specialties x
09 90 00 1.8 Painting
Paint Product Data x
Paint Samples x
10 28 13 1.4 Toilet Accessories x
SUBMITTAL LIST
Note: See tab below for Samples and Instructions. Attach to end of Specification Section 01 33 23 when complete.
Spec.
Sec. Par. No. Description
INFORMATIONAL ACTION
CUVA / 257393 / Comfort Station Upgrade
SUBMITTAL REQUIREMENTS (indicate with an "X")
T.
/L
A B
T
ES
T
R
EP
O R
T/ C
A
LC
O
R P
LA
N
M fg
. D A
TA
IN
ST
R U
C
TI
O N
S
SH
O
P D
R A
W
IN
G
SA
M
PL
E
M fg
. D A
TA
IN
ST
R U
C
TI
O N
S
221505 Ductile Iron Pipe and Fittings X
220523 Water Main Gate Valves X X
221514 Pipe Hangers and Supports X X
211116 Fire Hydrants X X
221505 Tapping Saddle X
Sht C5/C6 HDPE pipe X
Sht C7 Curb Stop X
Sht C8 Flush Hydrant, Check Valve, Pressure Regulator X X
221353 Septic Tank X
221353 Distribution Boxes X
Sht C9 Mound System Lateral Lines X X X X
Sht C9 Sanitary Sewer PVC Pipe X
322831 Fencing and Gates X
Sht C10 J-1000 Treatment System X X X X
SUBMITTAL LIST
Note: See tab below for Samples and Instructions. Attach to end of Specification Section 01 33 23 when complete.
Spec.
Sec. Par. No. Description
INFORMATIONAL ACTION
CUVA / 257393 / Comfort Station Upgrade
T.
/L
A B
T
ES
T
R
EP
O R
T/ C
A
LC
O
R P
LA
N
M fg
. D A
TA
IN
ST
R U
C
TI
O N
S
SH
O
P D
R A
W
IN
G
SA
M
PL
E
M fg
. D A
TA
IN
ST
R U
C
TI
O N
S
22 0400 Common Requireemnts for Plumbing X
22 0519 Meters and Gages for Pluming Piping
Product Data X
22 0719 Plumbing Piping Insulation
Product Data X
Manufacturer's Instructions X
22 1005 Plumbing Piping
Product Data X
22 1006 Plumbing Piping Specialties
Product Data X
Maintenance Data X
22 3300 Commercial Electric Domestic Water Heaters
Product Data X
Operation and Maintenance Data X
Warranty X
22 4000 Plumbing Fixtures
Product Data X
Manufacturer's Instructions X
Maintenance Data X
Warranty X
23 0400 Common Requireemnts for HVAC X
23 0593 Testing, Adjusting, and Balancing for HVAC
Installer Qualifications X
Contract Documents Examination Report X
Final Report X
Instrument Calibration X
23 0713 Duct Insulation
Product Data X
Manufacturer's Instructions X
23 3100 HVAC Ducts and Casings
Product Data X
SUBMITTAL LIST
Note: See tab below for Samples and Instructions. Attach to end of Specification Section 01 33 23 when complete.
Spec. Sec. Par. No. Description
INFORMATIONAL ACTION
Park/PMIS/Project Title
T.
/L
A B
T
ES
T
R
EP
O R
T/ C
A
LC
O
R P
LA
N
M fg
. D A
TA
IN
ST
R U
C
TI
O N
S
SH
O
P D
R A
W
IN
G
SA
M
PL
E
M fg
. D A
TA
IN
ST
R U
C
TI
O N
S
SUBMITTAL LIST
Note: See tab below for Samples and Instructions. Attach to end of Specification Section 01 33 23 when complete.
Spec. Sec. Par. No. Description
INFORMATIONAL ACTION
Park/PMIS/Project Title
SUBMITTAL REQUIREMENTS (indicate with an "X")
Manufacturer's Installation Instructions X
23 3300 Air Duct Accessories
Product Data X
23 3700 Air Outlets and Inlets
Product Data X
23 7223 Packaged Air-To-Air Energy Recovery Units
Product Data X
Manufacturer's Instructions X X
Operation and Maintenance Data X X
Warranty X
23 8200 Convection Heating and Cooling Units
Product Data X
Manufacturer's Instructions X
Operation and Maintenance Data X
Warranty X
26 0400 Common Requirements for Electrical Operation and Maintenance Manuals X
26 0526 Grounding and Bonding
Product Data-Ground Bars X X
26 2416 Panelboards
Product Data X
Shop Drawings X
Project Record Documents X
Maintenance Data X
26 2726 Wiring Devices
Product Data X X
26 2813 Fuses
Product Data X X
Extra Fuses X
26 5100 Interior Lighting
Shop Drawings X
Product Data X
T.
/L
A B
T
ES
T
R
EP
O R
T/ C
A
LC
O
R P
LA
N
M fg
. D A
TA
IN
ST
R U
C
TI
O N
S
SH
O
P D
R A
W
IN
G
SA
M
PL
E
M fg
. D A
TA
IN
ST
R U
C
TI
O N
S
SUBMITTAL LIST
Note: See tab below for Samples and Instructions. Attach to end of Specification Section 01 33 23 when complete.
Spec. Sec. Par. No. Description
INFORMATIONAL ACTION
Park/PMIS/Project Title
Operation and Maintenance Data X
| Submittal List Template |
| Blank Page |
| Section 013323_attachment (3) Civil.pdf |
| Submittal List Template |
| Section 013323_attachment (4) Elec.pdf |
| Submittal List Template |
| Section 013323_attachment (2) Arch.pdf |
| Submittal List Template |
| Section 013323_attachment (3) Civil.pdf |
| Submittal List Template |
| Section 013323_attachment (4) Elec.pdf |
| Submittal List Template |
File details come from the government source that posted it. Updated .