Drawings.pdf
PDF 12 MB Posted
- Attached to
- CUVA - Comfort Station Construction Federal contract opportunity
- Solicitation number
- 140P6421R0018
About this file
This document provides details of a federal contract solicitation for construction services. The National Park Service Midwest Region is seeking proposals for a project to renovate an existing comfort station at Cuyahoga Valley National Park in Brecksville, Ohio. Work will include upgrading the vault toilet facility to a temperature-controlled flush toilet system with running potable water and a septic tank/drain field. The project magnitude is estimated between $800,000 to $2,000,000. A firm-fixed price contract will be awarded, subject to Summit County, Ohio construction wage rates. Evaluation criteria are technical approach, past performance, and price. The NAICS code is 236220 for commercial and institutional building construction, with a size standard of $39.5 million. The solicitation is set aside 100% for small businesses. The point of contact is provided for any questions.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Site_Visit_Sign-in_Sheet_0001.pdf | ||
| Product_Specs_for_Approval__2_0001.pdf | ||
| Sol_140P6421R0018_Amd_0001.pdf | ||
| Product_Specs_for_Approval__1_0001.pdf | ||
| Questions_and_Answers_0001.pdf | ||
| Specifications_-_Comfort_Station.pdf | ||
| Sol_140P6421R0018.pdf | ||
| Notice_to_Contractors.pdf | ||
| Technical_Questionnaire.pdf | ||
| Technical_Questionnaire.docx | DOCX document | |
| Past_Performance_Questionnaire.pdf | ||
| Bid_Schedule_-_Comfort_Station.xlsx | XLSX spreadsheet | |
| Past_Performance_Questionnaire.docx | DOCX document | |
| Wage_Determination_-_Summit_County_OH.pdf | ||
| Updated_-_COVID-19_Mask_Policy.pdf | ||
| Submittal_List_-_Comfort_Station.pdf | ||
| Bid_Schedule_-_Comfort_Station.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUMMIT
BRANDYWINE FALLS COMFORT
STATION UPGRADE
BRANDYWINE FALLS PICNIC AREA
80070
A/E FIRM
PRIME/ARCH:
KENNETH HAHN ARCHITECTS
OMAHA, NE
CIVIL ENGINEER/CONSULTING FIRM:
OLSSON
OMAHA, NE
ELECTRICAL ENGINEER:
ALVINE ENGINEERING
OMAHA, NE
03/31/2021
03/31/2021
SCHEDULE OF DRAWINGSABBREVIATIONS
TILE(LARGE SCALE)
CARPET
BRICK PAVERS
ACOUSTICAL TILE
TERRAZZO
OR BOARD
STRUCTURAL STEEL
METAL STUD WALL
OTHER
(LARGE SCALE)
(SMALL SCALE)
WOOD STUD WALL
PARTICLE BOARD
PLYWOOD
FINISH WOOD
DIMENSION LUMBER
ROOF OR RIGID
FLASHING, DAMPROOFING
CAULKING OR SEALANT
BATT OR LOOSE
INSULATION
INSULATION
GLASS
GLASS
OR PLASTER
(SMALL SCALE)
GYPSUM WALLBOARD
(LARGE SCALE)
OR WATERPROFING
LAMINATED WOOD
CERAMIC OR QUARRY
CEMENT GYPSUM
CONCRETE MASONRY
LIGHTWEIGHT
METALS
CUT STONE
STEEL
CONCRETE MASONRY
COMPRESSIBLE
OR E.J. FILLER
BRICK
MASONRY
PRECAST
REINFORCEMENT
FINISHES
GLAZING
MOISTURE
THERMAL AND
PROTECTION
MATERIALS
BITUMINOUS PAVEMENT
CONCRETE POURED
CRUSHED ROCK
GRAVEL OR
SAND
SITE EARTH WOOD
REFERENCES
XX
DETAIL NUMBER
DETAIL SHEET NUMBER
SECTION NUMBER
SECTION SHEET NUMBER
ELEVATION NUMBER
ELEVATION SHEET NUMBER
COLUMN LINE
ROOM NAME AND NUMBER
DOOR NUMBER
WINDOW NUMBER
WALL TYPE
KEYNOTE
ELEVATION NUMBER
ELEVATION SHEET NUMBER
ELEVATION SYMBOL
ABOVE FINISHED FLOOR AFF
ACOUSTIC TILE CEILING ATC
ADJACENT ADJ
AIR CONDITIONING AC
ALTERNATE ALT
ALUMINUM ALUM
ANCHOR BOLT AB
ANGLE L
APPROXIMATELY APPROX
ARCHITECT ARCH
ARCHITECT / ENGINEER A/E
AT @
BASEMENT BSMT
BEAM BM
BEARING BRG
BLOCKING BLKG
BOARD BD
BOTTOM BOT
BOTTOM OF B.O.
BUILDING BLDG
CARPET CPT
CAST IRON CI
CEILING CLG
CENTERLINE CL
CERAMIC TILE CT
CHANNEL CH
CIRCUIT CKT
CLEANOUT CO
CLEAR CLR
CLOSET CLO
COMPACTED COMP
COMPRESSIBLE COMPR
CONCRETE CONC
CONCRETE MASONRY UNIT CMU
CONSTRUCTION CONST
CONTINUOUS CONT
CONTRACTOR CONTR
CONTROL JOINT CJ
CORRIDOR CORR
COUNTERSUNK CTSK
CURB C
DEAD LOAD DL
DETAIL DET
DIAMETER DIA
DIMENSION DIM
DISPENSER DISP
DISHWASHER DW
DOOR DR
DOUBLE DBL
DOWN DN
DOWNSPOUT DS
DRAWING DWG
DRINKING FOUNTAIN DF
EACH EA
ELECTRICAL ELEC
ELECTRIC WATER COOLER EWC
ELEVATION EL
ELEVATOR ELEV
ENGINEER ENGR
EQUAL EQ
EQUIPMENT EQUIP
EXHAUST FAN EF
EXISTING EXIST
EXPANSION EXP
EXPANSION JOINT EJ
EXTERIOR EXT
EXTERIOR INSULATION FINISH SYSTEM EIFS
FIELD VERIFY F.V.
FINISH FIN
FIRE ALARM FA
FIRE EXTINGUISHER FE
FIRE EXTINGUISHER CABINET FEC
FLATHEAD FH
FLEXIBLE FLEX
FLOOR FL
FLOORING FLRG
FLOOR DRAIN FD
FLUORESCENT FLUOR
FOOTING FTG
FOUNDATION FNDN
FRAME FR
FURRING FUR
GALVANIZED GALV
GAUGE GA
GLASS GL
GLASS FIBER REINFORCED PANEL GFRP
GLAZING GLZ
GRANULAR GRAN
GUTTER G
GYPSUM WALLBOARD GWB
HANDICAP HC
HARDWARE HDWE
HARDWOOD HDWD
HEIGHT HT
HIGH POINT HP
HOLLOW CORE HC
HOLLOW METAL HM
HORIZONTAL HORIZ
INSIDE DIAMETER ID
INSULATION INSUL
INTERIOR INT
JOINT JT
JOIST JST
KNEE SPACE KS
LAVATORY LAV
LIGHT LT
LIGHTWEIGHT LTWT
LIVE LOAD LL
LOW POINT LP
LUXURY VINYL TILE LVT
MARKERBOARD MB.
MANHOLE MH
MANUFACTURER MFR
MATERIAL MATL, MAT
MECHANICAL MECH
MEDICINE CABINET MC
METAL MET
METAL BUILDING PANEL MBP
METAL WALL PANEL MWP
MINIMUM MIN
MISCELLANEOUS MISC
MOUNT MT
NOT IN CONTRACT NIC
NOT TO SCALE NTS
NUMBER NO.
ON CENTER O.C.
OPENING OPNG
OPPOSITE OPP
ORIENTED STRAND BOARD OSB
OUTSIDE AIR OA
OUTSIDE DIAMETER OD
PAINT PT
PANEL PNL
PARTITION PART
PLASTER PLAS
PLASTIC LAMINATE PLAM
PLATE PL
PLYWOOD PLYWD
POLISHED POL
POUND LB
PROPERTY PROP
QUARRY TILE QT
RADIUS R
RECESSED REC
REFERENCE REF
REFRIGERATOR REFRIG, REF
REGARDING RE:
REINFORCE REINF
REQUIRED REQ
RESILIENT BASE RB
RETURN AIR RA
REVERSE REV
RISER R
ROOF DRAIN RD
ROOM RM
ROUGH OPENING RO
ROUND RND
SCHEDULE SCHED
SECTION SET
SHEET SHT
SHEET METAL SM
SHEET VINYL SV
SHEET VINYL BASE SVB
SIMILAR SIM
SLAB-ON-GRADE SOG
SPECIFICATIONS SPEC
SQUARE SQ
SQUARE FOOT SF
STEEL STL
STORAGE STOR
STRUCTURAL STRUCT
SUPPLY AIR SA
SUSPENDED SUSP
TACKBOARD TB.
TELEPHONE TELE
TEMPERATURE TEMP
TERRAZZO TERR
TOILET TLT
TONGUE & GROOVE T&G
TOP OF T.O.
TOP OF STEEL TOS
TREAD T
TYPICAL TYP
UNDERGROUND UG
UNLESS NOTED OTHERWISE UNO
URINAL UR
VERTICAL VERT
VESTIBULE VEST
VINYL COMPOSITION TILE VCT
VINYL WALLCOVERING VWC
WATER CLOSET WC
WATER HEATER WH
WEIGHT WT
WELDED WIRE FABRIC WWF
WHERE OCCURRING W.O.
WOOD WD
X A-X01
X A-X01
XX.XX
X
X
X
A-X01
X
ROOM
NAME
XXXX
XX
XX
ELEV. = 100'-0"
FINISH FLOOR
XX
GENERAL NOTES
XXX
1. IN THE EVENT OF DISCREPANCIES WITHIN THE DRAWINGS OR SPECIFICATIONS, THE GREATER QUALITY AND QUANTITY OF THE ITEMS IN QUESTION SHALL BE UTILIZED AT ALL LOCATIONS WHERE SUCH DISCREPANCIES OCCUR IN THE EVENT DISCREPANCIES BETWEEN THE DRAWINGS
AND THE SPECIFICATIONS OCCURS, THE SPECIFICATIONS SHOULD BE USED.
2. THE LOCATION OF ALL UNDERGROUND UTILITIES MAY NOT BE INDICATED ON THESE PLANS, AND SOME LOCATIONS MAY BE INACCURATE. NO EXCAVATION WILL BE PERMITTED IN THE AREA OF UNDERGROUND UTILITIES UNTIL SUCH UTILITIES HAVE BEEN LOCATED AND IDENTIFIED TO THE SATISFACTION OF ALL PARTIES, AND THEN ONLY WITH EXTREME CAUTION TO AVOID ANY POSSIBILITY OF DAMAGE TO THE UTILITY OR PERSONAL INJURY. HAND-DIGGING MAY BE REQUIRED WHEN THE EXCAVATION AND UTILITIES ARE EXTREMELY CLOSE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REPAIR AND REPLACEMENT COST OF ANY UNDERGROUND UTILITY DAMAGE.
3. THE FOLLOWING UTILITY FEES WERE IDENTIFIED DURING THE DESIGN PROCESS AS BEING REQUIRED (REFER TO ADDITIONAL INSTRUCTIONS AT SPEC SECTIONS 01 31 00 AND 01 73 40):
a. CLEVELAND WATER (CW) EXISTING WATER MAIN TAP FEE
b. CLEVELAND WATER (CW) WATER METER FEE
4. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND SHALL BE RESPONSIBLE FOR THE SAME. COORDINATE ALL WORK AND SHOP DRAWINGS WITH OTHER TRADES.
5. THE CONTRACTOR SHALL COORDINATE ALL TESTING AND INSPECTIONS AS SPECIFIED, OR AS NECESSARY TO DEMONSTRATE A COMPLETE AND SATISFACTORY INSTALLATION.
6. ALL WORK SHALL COMPLY WITH APPLICABLE CODES, REGULATIONS, AND ORDINANCES.
7. ALL MATERIALS AND EQUIPMENT OF THE SAME TYPE SHALL BE SUPPLIED BY THE SAME MANUFACTURER, AND SHALL BE NEW, OF THE BEST QUALITY AND DESIGN, AND FREE FROM DEFECTS.
8. ALL ITEMS ARE NEW UNLESS SPECIFICALLY IDENTIFIED AS EXISTING.
9. "PROVIDE" MEANS TO FURNISH AND INSTALL.
10. THE CONTRACTOR SHALL COORDINATE ON-SITE STORAGE OF BUILDING MATERIALS, EQUIPMENT, AND TRASH CONTAINERS WITH GOVERNMENT.
11. ALL BUILDING DIMENSIONS ARE TO FACE OF GYPSUM WALL BOARD , COLUMN CENTERLINE, OR OUTSIDE FACE OF EXTERIOR WALL SHEATHING, UNLESS NOTED OTHERWISE.
12. ALL ANGLES ON PLANS ARE 45- OR 90-DEGREES, UNLESS NOTED OTHERWISE
13. THE GOVERNMENT RESERVES THE RIGHT TO REMOVE ANY ITEMS FROM THE CONSTRUCTION AREA PRIOR TO THE START OF DEMOLITION WORK BY THE CONTRACTOR AND TO RETAIN SUCH ITEMS AS THEIR PROPERTY.
14. IT IS THE INTENT OF THIS CONTRACT THAT ALL AREAS AFFECTED BY CONSTRUCTION BE A FINISHED AND COMPLETE PROJECT. CONTRACTOR SHALL PATCH, REPAIR, AND ADJUST AS REQUIRED TO ACHIEVE THIS FINISHED PROJECT.
GENERAL
1. G1 COVER SHEET
2. G2 DRAWING INDEX, LEGEND AND ABBREVIATIONS
3. G3 WATER SYSTEM INSTALLATION NOTES
CIVIL
4. V1 TOPOGRAPHIC SURVEY
5. C1 8" WATER MAIN (0+00 TO 5+50)
6. C2 8" WATER MAIN (5+50 TO 10+75)
7. C3 8" WATER MAIN (10+75 TO 15+94.78)
8. C4 3" WATER MAIN (0+00 TO 3+25)
9. C5 3" WATER SERVICE LINE (3+25 TO 6+50)
10. C6 3" WATER SERVICE LINE (6+50 TO 9+81.25)
11. C7 WATER SYSTEM DETAILS
12. C8 WATER SYSTEM DETAILS
13. C9 WASTEWATER TREATMENT AND DISPOSAL ELEVATED MOUND SYSTEM
PLAN LAYOUT
14. C10 WASTEWATER TREATMENT AND DISPOSAL SYSTEMS DETAILS
15. C11 WASTEWATER TREATMENT AND DISPOSAL SYSTEMS DETAILS
ARCHITECTURAL
16. A1 REMOVAL PLANS
17. A2 FLOOR PLANS AND ROOM FINISH SCHEDULE
18. A3 EXTERIOR ELEVATIONS
19. A4 ROOF PLAN AND BUILDING SECTIONS
20. A5 WALL SECTIONS AND DETAILS
21. A6 DOOR AND FRAME SCHEDULE, FRAME TYPES & DETAILS, WALL TYPES AND
INTERIOR ELEVATIONS
STRUCTURAL
22. S1 STRUCTURAL GENERAL NOTES
23. S2 STRUCTURAL GENERAL NOTES & ROOF FRAMING PLAN
24. S3 STRUCTURAL DETAILS
MECHANICAL
25. M0 MECHANICAL SYMBOL LEGEND AND ABBREVIATIONS.
26. M1 MECHANICAL DEMOLITION FLOOR PLANS.
27. M2 MECHANICAL FLOOR PLANS - PLUMBING.
28. M3 MECHANICAL FLOOR PLANS-HVAC.
29. M4 PLUMBING RISER DIAGRAM AND MECHANICAL DETAILS.
30. M5 MECHANICAL SCHEDULES.
ELECTRICAL
31. E0 ELECTRICAL SYMBOLS AND ABBREVIATIONS.
32. E1 ELECTRICAL DEMOLITION PLANS.
33. E2 LIGHTING FLOOR PLANS.
34. E3 POWER FLOOR PLANS.
35. E4 ELECTRICAL RISER DIAGRAM AND DETAILS.
36. E5 ELECTRICAL SCHEDULES.
DRAWING INDEX, LEGEND
AND ABBREVIATIONSG2
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
KJH
CLZ
GJH
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A p r a m
Y
B r a n d y w i n e
C o m f o r t
S t a t i o n
C
U V
A S
U B
M I T
T A
L S
F
I N
A L
C
D
R
E S
U B
M I T
T A
L D
R A
W I N
G S
D
W G s
C
U V
A G d w g
U
S E
R
C a r e y
FINAL CONSTRUCTION DOCUMENTS
WATER SYSTEM
INSTALLATION NOTESG3
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 6
:0 8a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
-C
UV
A-
G3 -R
.d wg
US
ER
th ill
CLEVELAND WATER SYSTEM INSTALLATION NOTES
BRANDYW
INE RO
AD (R/W
60')
BRANDYW
INE ROAD (R/W
60')
BRANDYW
INE ROAD (R/W
60')
RELOCATED STANDFORD ROAD
I-271
LEGEND
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 6
:0 6a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
_C
UV
A_
V1 -R
.d wg
US
ER
th ill
FINAL CONSTRUCTION DOCUMENTS
Olsson and the surveyor of record make no guarantees that the underground utilities shown hereon comprise all such utilities in the area, either in service or abandoned. Olsson and the surveyor of record further does not warrant that the underground utilities shown are in the exact location indicated. Olsson and the surveyor of record have not physically located the underground utilities.
If any underground utility locations are required, they will have to be verified by field pot-holing the utilities. Olsson and the surveyor of record shall not be liable for the location of or the failure to note the location of non-visible utilities. Utilities were ordered to be located per one-call ticket number B825500248. The companies listed on the ticket are CEI, CWDP, EOM, LVTP, MCIP, NRSP, OBFP, SXFP and VVV.
Above ground utility appurtenances found as shown. (SUE Level B)
Contractor responsible for ensuring known area utilities are marked in field prior to construction. Notify Engineer and Owner of any potential design changes as a result of marked utilities.
UTILITY NOTE
PREPARED BY
PREPARED FOR
OLSSON
550 ST. LOUIS STREET
SPRINGFIELD, MO 65806
U.S. NATIONAL PARK SERVICE
MWR DESIGN AND FACILITY MANAGEMENT
820 COLUMBUS STREET
RAPID CITY, SD 57701
BASIS OF BEARINGS
Grid North based on Ohio State Plane
Coordinate System 2011 by use of ODOT VRS system
DATUM
Elevations based on NAVD 88 by use of ODOT VRS system
HORIZONTAL AND VERTICAL CONTROL
TOPOGRAPHIC SURVEYV1
BRANDYWINE ROAD (R/W 60')
8" WATER MAIN (STA 0+00 TO STA 5+50)
0+00 1+00 2+00 3+00 4+00 5+00 5+75
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 6
:0 5a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
_C
UV
A_
C1 -R
.d wg
US
ER
th ill
FINAL CONSTRUCTION DOCUMENTS
8" WATER MAIN
(STA 0+00 TO STA 5+50)C1
5+25 6+00 7+00 8+00
8" WATER MAIN (STA 5+50 TO STA 8+00)
8+00 9+00 10+00 10+75
8" WATER MAIN (STA 8+00 TO STA 10+75)
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 6
:0 4a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
_C
UV
A_
C2 -R
.d wg
US
ER
th ill
FINAL CONSTRUCTION DOCUMENTS
8" WATER MAIN
(STA 5+50 TO STA 10+75)C2
8" WATER MAIN (STA 10+75 TO STA 15+94.78)
10+75 11+00 12+00 13+00 14+00 15+00 15+84.80
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 6
:0 3a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
_C
UV
A_
C3 -R
.d wg
US
ER
th ill
FINAL CONSTRUCTION DOCUMENTS
8" WATER MAIN
(STA 10+75 TO STA 15+94.78)C3
3" SERVICE LINE (STA 0+00 TO STA 3+25)
0+00 1+00 2+00 3+00 3+25
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 6
:0 1a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
_C
UV
A_
C4 -R
.d wg
US
ER
th ill
FINAL CONSTRUCTION DOCUMENTS
3" SERVICE LINE
(STA 0+00 TO STA 3+25)C4
NOTES:
THIS 3" SERVICE LINE ROUTE INCLUDES THREE CROSSINGS OF
A PAIR OF GAS LINES - ONE NATURAL GAS PIPELINE AND ONE
LIQUID GAS PIPELINE.
NORTH COAST GAS TRANSMISSION LEASES THESE LINES FROM
BUCKEYE PARTNERS. THE EXACT LOCATION, DEPTH, AND
EASEMENT WIDTH FOR THE PIPELINES IS EITHER UNKNOWN OR
IS BASED ON AVAILABLE RECORDS SHARED DURING THE
DESIGN OF THIS PROJECT, AS DESCRIBED BELOW.
THE NEW WATER LINE MUST CROSS UNDER THESE GAS LINES
WITH A VERTICAL CLEARANCE OF AT LEAST TWO FEET (2')
THROUGHOUT THE ENTIRETY OF THE GAS LINE EASEMENT.
RECORDED WIDTH OF THE GAS EASEMENT IS CURRENTLY
UNKNOWN. THE DEPTH OF THESE GAS LINES ARE ASSUMED TO
BE 48" AND 6'. ACTUAL DEPTHS ARE TO BE VERIFIED IN THE
FIELD.
CONTRACTOR TO COORDINATE GAS PIPELINE CROSSINGS WITH
LEE LOCHTEFELD (614)505-7419 TO DEVELOP A CROSSING
AGREEMENT WITH THE PIPELINE COMPANY BEFORE
CONSTRUCTION BEGINS.
THIS ROUTE ALSO INCLUDES TWO TRAIL CROSSINGS.
CONTRACTOR TO COORDINATE WITH NPS DURING
CONSTRUCTION.
3" SERVICE LINE TO BE INSTALLED VIA HORIZONTAL
DIRECTIONAL DRILLING (HDD) WHERE FEASIBLE, WITH
OPEN-CUT INSTALLATION AT GAS LINE CROSSINGS. UTILITY
CROSSINGS TO BE POTHOLED TO DETERMINE DEPTH AND
NEEDED CLEARANCE PRIOR TO INSTALLATION.
3+254+005+006+006+50
3" WATER SERVICE LINE (STA 3+25 TO STA 6+50)
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 6
:0 0a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
_C
UV
A_
C5 -R
.d wg
US
ER
th ill
FINAL CONSTRUCTION DOCUMENTS
3" WATER SERVICE LINE
(STA 3+25 TO STA 6+50)C5
NOTES:
THIS 3" SERVICE LINE ROUTE INCLUDES THREE CROSSINGS OF
A PAIR OF GAS LINES - ONE NATURAL GAS PIPELINE AND ONE
LIQUID GAS PIPELINE.
NORTH COAST GAS TRANSMISSION LEASES THESE LINES FROM
BUCKEYE PARTNERS. THE EXACT LOCATION, DEPTH, AND
EASEMENT WIDTH FOR THE PIPELINES IS EITHER UNKNOWN OR
IS BASED ON AVAILABLE RECORDS SHARED DURING THE
DESIGN OF THIS PROJECT, AS DESCRIBED BELOW.
THE NEW WATER LINE MUST CROSS UNDER THESE GAS LINES
WITH A VERTICAL CLEARANCE OF AT LEAST TWO FEET (2')
THROUGHOUT THE ENTIRETY OF THE GAS LINE EASEMENT.
RECORDED WIDTH OF THE GAS EASEMENT IS CURRENTLY
UNKNOWN. THE DEPTH OF THESE GAS LINES ARE ASSUMED TO
BE 48" AND 6'. ACTUAL DEPTHS ARE TO BE VERIFIED IN THE
FIELD.
CONTRACTOR TO COORDINATE GAS PIPELINE CROSSINGS WITH
LEE LOCHTEFELD (614)505-7419 TO DEVELOP A CROSSING
AGREEMENT WITH THE PIPELINE COMPANY BEFORE
CONSTRUCTION BEGINS.
THIS ROUTE ALSO INCLUDES TWO TRAIL CROSSINGS.
CONTRACTOR TO COORDINATE WITH NPS DURING
CONSTRUCTION.
3" SERVICE LINE TO BE INSTALLED VIA HORIZONTAL
DIRECTIONAL DRILLING (HDD) WHERE FEASIBLE, WITH
OPEN-CUT INSTALLATION AT GAS LINE CROSSINGS. UTILITY
CROSSINGS TO BE POTHOLED TO DETERMINE DEPTH AND
6+507+008+009+009+90
3" WATER SERVICE LINE (STA 6+50 TO STA 9+81.25)
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 9
:0 3a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
0_
CU
VA
_C 6-
R1 3.
dw g
- U
SE
R th ill
FINAL CONSTRUCTION DOCUMENTS
3" WATER SERVICE LINE
(STA 6+50 TO STA 9+81.25)C6
NOTES:
THIS 3" SERVICE LINE ROUTE INCLUDES THREE CROSSINGS OF
A PAIR OF GAS LINES - ONE NATURAL GAS PIPELINE AND ONE
LIQUID GAS PIPELINE.
NORTH COAST GAS TRANSMISSION LEASES THESE LINES FROM
BUCKEYE PARTNERS. THE EXACT LOCATION, DEPTH, AND
EASEMENT WIDTH FOR THE PIPELINES IS EITHER UNKNOWN OR
IS BASED ON AVAILABLE RECORDS SHARED DURING THE
DESIGN OF THIS PROJECT, AS DESCRIBED BELOW.
THE NEW WATER LINE MUST CROSS UNDER THESE GAS LINES
WITH A VERTICAL CLEARANCE OF AT LEAST TWO FEET (2')
THROUGHOUT THE ENTIRETY OF THE GAS LINE EASEMENT.
RECORDED WIDTH OF THE GAS EASEMENT IS CURRENTLY
UNKNOWN. THE DEPTH OF THESE GAS LINES ARE ASSUMED TO
BE 48" AND 6'. ACTUAL DEPTHS ARE TO BE VERIFIED IN THE
FIELD.
CONTRACTOR TO COORDINATE GAS PIPELINE CROSSINGS WITH
LEE LOCHTEFELD (614)505-7419 TO DEVELOP A CROSSING
AGREEMENT WITH THE PIPELINE COMPANY BEFORE
CONSTRUCTION BEGINS.
THIS ROUTE ALSO INCLUDES TWO TRAIL CROSSINGS.
CONTRACTOR TO COORDINATE WITH NPS DURING
CONSTRUCTION.
3" SERVICE LINE TO BE INSTALLED VIA HORIZONTAL
DIRECTIONAL DRILLING (HDD) WHERE FEASIBLE, WITH
OPEN-CUT INSTALLATION AT GAS LINE CROSSINGS. UTILITY
CROSSINGS TO BE POTHOLED TO DETERMINE DEPTH AND
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 5
:5 3a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
1_
CU
VA
_C 7-
R1 3.
dw g
- U
SE
R th ill
FINAL CONSTRUCTION DOCUMENTS
SCALE: NONE
INSULATED CASING FIELD JOINT DETAIL SCALE: NONE
SLEEVE FOR WATER MAIN AT ABUTMENTS DETAIL PROFILE VIEW
SCALE: NONE
INSULATED CASING EXPANSION JOINT DETAIL
SCALE: NONE
6" INSULATED CASING DETAIL
SCALE: NONE
WATER SERVICE CONNECTION
SCALE: NONE
TYPICAL FROST PROOFING DETAIL
SCALE: NONE
VERTICAL BEND BLOCKING DETAIL
WATER SYSTEM
DETAILSC7
11SCALE: NONE
PARTIAL WATER SERVICE CONNECTION FOR INN
SCALE: NONE
METER SET DETAIL
ROOT PRUNING NOTES:
TREE PRESERVATION NOTES
TREE PROTECTION NOTES:
TREE REMOVAL NOTES:
SCALE: NONE
TYPICAL FLUSH HYDRANT ASSEMBLY
SCALE: NONE
VALVE AND BOX INSTALLATION DETAIL
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 5
:5 2a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
2_
CU
VA
_C 8-
R1 3.
dw g
- U
SE
R th ill
FINAL CONSTRUCTION DOCUMENTS
SCALE: NONE
TREE PROTECTION DETAIL
SCALE: NONE
WATER MAIN AND SERVICE LINE TRENCH DETAIL
IN EARTH IN ROCK
SCALE: NONE
TYPICAL NEW HYDRANT INSTALLATION DETAIL
SCALE: NONE
ASPHALT REPAIR
WATER SYSTEM
DETAILSC8
SCALE: NONE
PIPE SUPPORT AT BRIDGE
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 5
:5 0a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
3_
CU
VA
_C 9-
R1 3.
dw g
- U
SE
R th ill
FINAL CONSTRUCTION DOCUMENTS
WASTEWATER TREATMENT
AND DISPOSAL ELEVATED
MOUND SYSTEM PLAN LAYOUTC9
TREE REMOVAL NOTES:
AA
B
B
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 5
:4 9a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
4_
CU
VA
_C
-R
.d wg
US
ER
th ill
FINAL CONSTRUCTION DOCUMENTS
WASTEWATER TREATMENT
AND DISPOSAL SYSTEM
DETAILSC10
SCALE: NONE
LEVEL (<5% SLOPE) ELEVATED MOUND SYSTEM SECTION
SCALE: NONE
LATERAL CROSS SECTION DETAIL
SCALE: NONE
OBSERVATION PORT DETAIL
SCALE: NONE
1,500 GALLON DUAL-COMPARTMENT SEPTIC TANK WITH AERATED WWTP PLAN
SCALE: NONE
1,500 GALLON SEPTIC TANK WITH AERATED TANK SECTION A-A
SCALE: NONE
DIVISION BOX PLAN
SCALE: NONE
DIVISION BOX SECTION B-B
SCALE: NONE
SEWER CONNECTION TO EXISTING DETAIL
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
JGJ
TMH
DLE
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
1,
- 5
:4 0a m F
:\2
9\
-2
0\
9-
\8 0-
Cu rre nt \P lan s\2
1-
-3 0\
5_
CU
VA
_C
-R
.d wg
US
ER
th ill
FINAL CONSTRUCTION DOCUMENTS
WASTEWATER TREATMENT
AND DISPOSAL SYSTEM
DETAILSC11
SCALE: NONE
ONE-WAY CLEANOUT DETAIL
SCALE: NONE
TYPICAL SITE FENCE DETAIL
SCALE: NONE
TWO-WAY CLEANOUT DETAIL
SCALE: NONE
REMOVABLE BOLLARD WITH CHAIN DETAIL
SCALE: NONE
TYPICAL GRAVEL PATH DETAIL SECTION
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
BASEMENT REMOVAL PLAN
N
25'-0" F.V.
'-0
" F .V
SUMP
7'-0" F.V. 11'-0" F.V. 7'-0" F.V.
5'- 6"
DN
EXISTING WOOD FENCE
TO REMAIN
EXISTING RAILROAD TIE RETAINING WALL
TO REMAIN
EXIST. C.S.
ACCESS PANEL
EXISTING LANDING
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
MAIN FLOOR REMOVAL PLAN
N
25'-0" F.V.
'-0
" F .V
MEN
WOMEN
EXISTING ASPHALT PAVEMENT TO REMAIN
N
PLAN TRUE
N
TRUEPLAN
1. REMOVE ALL WOOD FRAMED BUILDING COMPLETE SHOWN BOLD AND DASHED. CONCRETE
FLOORS AND FOUNDATION TO REMAIN.
2. REMOVE ALL PLUMBING FIXTURES COMPLETE SHOWN BOLD AND DASHED; SEE
MECHANICAL.
3. REMOVE ASPHALT PAVEMENT.
4. RELOCATE ELECTRICAL METER; SEE ELECTRICAL.
5. REMOVE SEPTIC TANKS AND ALL PIPING; SEE MECHANICAL.
6. REMOVE STORM WATER PIPING ABOVE GRADE. STORM WATER PIPE +/-2'-0" ABOVE GRADE
AND BELOW GRADE TO REMAIN - SEE PLUMBING PLAN FOR INFORMATION ON CONNECTING
NEW PIPE TO EXISTING.
7. REMOVE CONCRETE PAD.
8. REMOVE STORM DRAIN TO BE RELOCATED. STORM WATER PIPE BELOW GRADE TO REMAIN
- SEE PLUMBING PLAN FOR INFORMATION ON CONNECTING NEW DRAIN AND PIPE TO
EXISTING PIPING.
9. REMOVE MIN. FLOOR SLAB OPENING FOR MECH. DUCT RUN PENETRATIONS; SEE MECH
DRAWINGS.
REMOVAL PLAN KEY NOTES
TYP.
REMOVAL PLANS
A1
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
KJH
CLZ
GJH
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
r
B r a n d y w i n e
C o m f o r t
S t a t i o n
C
U V
A D
R A
W I N
G S
C
U V
A A d w g
U
S E
R
C a r e
BASEMENT PLAN
N
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
MAIN FLOOR PLAN
N
EXISTING ASPHALT PAVEMENT TO REMAIN
25'-0" F.V.
8'-10" 7'-4" 8'-10"
8'- 4"
M
AS
7'-
4" 9'-
4" M
AS
'-0
" F .V
7'-0"
7'-0"
5'- 6"
4 1 /8"
4 1 /8"
102101
MEN
WOMEN
JAN.
8'- 4"
M
AS
7'-
4" 9'-
4" M
AS
'-0
" F .V
8'-8"
2'-1"
5'- 2"8'-
2 1 /2"
2'-6"
6'- 0"
6" 6"
A4
A4
A4
CONC. APRON; SEE 3/A2
1'-8"1'-8"
A3
A3
A3
A3
8 x 8 POST
ON CONC.
PIER TOP;
SEE STRUC'L
25'-0" F.V.
8'-8" 7'-8"
EQEQ
A6
8A 8B
8C
A6
7B 7A7C
2B A3
STACK COLUMN ATOP CMU
WALL BELOW; SEE STRUCT'L
C1
A1
B1
A1
B1
A1
A1A1
A1
COLUMN ATOP
CMU WALL; SEE
STRUCTL
ELEC. METER;
SEE ELEC.
MOP SINK
D.F.
TRENCH DRAIN; DAYLIGHT
TO WEST PER 3/A2
3'-2 1/2" +/-
1'-0"
2'-0"2'-0"
F02 F03
A1
A1
'-4
8'-4"
HD-1
HD-1
C1
9'- 3 1
/2"
4" 4" 9'-4"
5'-2"
SUMP
DN
EXISTING WOOD FENCE
TO REMAIN
EXISTING RAILROAD TIE RETAINING WALL
TO REMAIN
EXIST. C.S.
ACCESS PANEL
EXISTING LANDING
8'- 4"
'-0
" F .V
7'-
4"
8'- 4"
7'- 4"
'-0
F
.V
6"6"
6'- 0"
A4
A4
A4
EXIST. CRAWL SPACE
PIER FOOTING SEE STRUCTURAL
BASEMENT
SEE MECH/ELEC
ERU; SEE MECH.
EXISTING MASONRY WALL
CORE DRILL FOR PLUMBING;
REFER TO DETAIL AT 3/A4
SEE ELEC
N
PLAN TRUE
N
TRUEPLAN
1. CAST IN PLACE CONCRETE (SEE STRUCTURAL DETAILS).
2. BABY CHANGING STATION; SEE SHEET A6 ELEVATIONS
3. FIRE EXTINGUISHER CABINET, FEC-1
4. DOOR ACTIVATOR
5. GROUT TO FILL THE EXISTING T.O. GROUT SHALL BE SMOOTH AND LEVEL/FLUSH WITH
ADJACENT SLAB SURFACE.
6. PROVIDE BLOCKING AT WALLS TO ANCHOR URINAL AND TOILET PARTITIONS
7. ABUSE RESISTANT GWB AT WALLS (TYPICAL)
FLOOR PLAN KEY NOTES
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
APRON PLAN
N
N
PLAN TRUE
2 2
TRENCH DRAIN; SEE 4/A4
EXIST. SLAB
'-0
8'-0"+/-
MATCH
EXIST.
ELEV.
EXIST.
ELEV.
MATCH
EXIST.
ELEV.
EXIST.
ELEV.
6'- 9"
3'- 4"
2% S
LO
PE
EX
IS
T.
SL
OP
E
CONC
EXIST.
ASPHALT
C O
N C
E
X I S
T
A
S P
H A
L T
CONC. APRON
MATCH
EXIST.
ELEV.
EXIST.
ELEV.
100.00 (EXIST)
100.00
100.00 (EXIST)
100.00 100.00
DAYLIGHT
DOWN SLOPE
99.9+/-
EXIST.
4 4
98.4
(MAX)
98.2+/-
EX
IS
T.
SL
OP
E
SL
OP
E A
S
RE
Q' D
PE
R
DE
TA
IL
2/A
A4
A4
EXIST.
ELEVATION
AT BUILDING'S
SW CORNER
EX
IS
T.
SL
OP
E
EX
IS
T.
SL
OP
E
TYP.
FLOOR PLANS AND ROOM
FINISH SCHEDULEA2
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
KJH
CLZ
GJH
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
r
B r a n d y w i n e
C o m f o r t
S t a t i o n
C
U V
A D
R A
W I N
G S
C
U V
A A d w g
U
S E
R
C a r e y
FINAL CONSTRUCTION DOCUMENTS
NOTES
ROOM FINISH SCHEDULE
NO. DESCRIPTION FLOOR BASE
NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING
MAT. FIN. MAT. FIN. HEIGHTMAT. FIN. MAT. FIN. MAT. FIN.
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
EFC EPOXY FLOOR COATING
EWC EPOXY WALL COATING
EX EXISTING
EXP EXPOSED
FRP FIBER GLASS-REINFORCED PLASTIC
GWB GYPSUM WALLBOARD
P PAINT
VB VINYL BASE
ROOM FINISH SCHEDULE LEGEND
NOTE: REFER TO COLOR SCHEDULE FOR ALL INTERIOR FINISHES.
001 BASEMENT EX CONC - - EX CONC EFC-1 EX CONC EFC-1 EX CONC EFC-1 EX CONC EFC-1 EX DECK EWC-1 - - 1, 2 101 MEN EX CONC VB-1 GWB EFC-1 GWB EFC-1 GWB EFC-1 GWB EFC-1 GWB P-1 SLOPED 1, 3, 4 102 WOMEN EX CONC VB-1 GWB EFC-1 GWB EFC-1 GWB EFC-1 GWB EFC-1 GWB P-1 SLOPED 1, 3, 4
103 JANITOR EX CONC VB-1 CMU EFC-1 GWB EFC-1 CMU EFC-1 GWB EFC-1 EXP P-1 - -
ROOM FINISH SCHEDULE NOTES
1. (2) COATS EPOXY COATING AT SLAB WITH COVE; SEE SPEC
2. EPOXY COATING AT WALLS AND CEILING (MTL DECK); SEE SPEC
3. EPOXY WALL COATING AT WALLS; SEE SPEC
4. ABUSE RESISTANT GWB AT WALLS (TYPICAL)
WEST ELEVATION
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
SOUTH ELEVATION
EXISTING RAILROAD
TIES RETAINING WALL
TO REMAIN
STANDING SEAM ROOF
8"x8" TREATED
WOOD POST; ST-1
EXISTING HOLLOW
METAL DOOR AND
FRAME TO REMAIN
CEMENT BD
LAP SIDING; P-3
8INSULATED
TRANSLUCENT
WALL PANEL
ATTIC VENT
ROOF RIDGE
CEMENT BD LAP SIDING; P-3
SPLIT FACE CMU
CEMENT BD
LAP SIDING; P-3
SPLIT FACE CMU
CAST-IN-PLACE
EXIST
FOUNDATION
ELEC. METER;
SEE ELEC
DRAWINGS
LOUVER; SEE MECH.
AF
A4
A4
P-4 AT CEMENT BD
TRIM AT HEADER; SEE
STRUCTURAL 2/S2
STANDING SEAM ROOF
8"x8" CEDAR
POST; SEE
STRUCT'L
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
EAST ELEVATION
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
NORTH ELEVATION
CEMENT BD LAP
SIDING; P-3
FILL IN HOLES AT
REMOVED
SEPTIC
CONNECTION
PIPES
ROOF RIDGE
SPLIT FACE CMU SPLIT FACE CMU
EXIST
FOUNDATION CAST-IN-PLACE
DRINKING
FOUNTAIN
ST-1 8"x8"
CEDAR POST;
SEE STRUCT'L
8x8 TIMBER TRUSS; ST-1
AF
AF
A4
A4
CEMENT BD
FASCIAS &
SOFFITS; P-4
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
NORTH ELEV / COVERED ENTRY SECTION
2B
SPLIT FACED
CMU
CEMENT BD
LAP SIDING; P-3
ATTIC VENT
LT FIXT (SEE ELEC.);
T.O. FIXTS AT 8'-0"
AFF TO ALIGN W/
CMU COURSING
(TYPICAL)
8x10 TIMBER BM
FLASH TOP OF WING
WALL AS REQUIRED
8x10 TIMBER BM; ST-1
LOUVER; SEE MECH.
8 x 16 SMOOTH
FACED CMU AT
(BEHIND) LT FIXT
MOUNT PLATES
(TYPICAL)
EXTERIOR ELEVATIONS
A3
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
KJH
CLZ
GJH
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
r
B r a n d y w i n e
C o m f o r t
S t a t i o n
C
U V
A D
R A
W I N
G S
C
U V
A A d w g
U
S E
R
C a r e
SLOPE 8/12 SLOPE 8/12
ROOF PLAN
N
N
PLAN TRUE
1. STANDING SEAM METAL ROOF
2. ROOF RIDGE; SEE DETAIL 7/A5
3. EAVE VENT IN EAVE SOFFIT BELOW; SEE 1/A5
ROOF PLAN KEY NOTES
8" CMU
EXIST. STRUCTURE
FRP
2 x 10
3/4" SHEATHING
WEATHER BARRIER
STANDING SEAM METAL ROOF
2 x 6 COLAR; SEE STRUCTURAL
5/8" GWB
A5
RIDGE BM; SEE STRUCT'L
AF
2 LAYERS OF 2" SPRAY FOAM INSULATION
DUCT; SEE MECH.
ELEV. = 100'-0"
EXIST. SLAB/ FINISH FLR
ELEV. = 90'-4"+/- (F.VER.)
EXIST BASEMENT SLAB
5/8" ON 2 x 6
STUDS
CAST-IN-PLACE CONC. WALL;
SEE STRUCTURAL
5/8" ON 2X10 JOISTS
JAN.
ELEV. = 100'-0"
EXIST. SLAB/ FINISH FLR
ELEV. = 114'-0"
B.O.COLAR
ELEV. = 90'-4"+/- (F.VER.)
EXIST BASEMENT SLAB
MEN WOMEN
STANDING SEAM METAL ROOF
RIDGE BM; SEE STRUCT'L
A5
CORE DRILL FOR PLUMBING;
SEE BASEMENT PLAN 1/A2
EXIST. STRUCTURE
A5
RIGID INSUL
AF
2 LAYERS OF 2" SPRAY FOAM INSULATION
DUCT; SEE MECH.
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
BUILDING SECTION
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
BUILDING SECTION
5/8" GWB ON 2X8 JOISTS
8" SPLIT FACE CMU
EXIST. STRUCTURE
TRENCH DRAIN
CEMENT BD EAVE; P-4
A5
A5
A5
FORMED PIER TOP; SEE STRUCT'L
ELEV. = 96'-0"
B.O. PIER
ELEV. = 100'-0"
EXIST. SLAB
18" DIA PIER; SEE STRUCT'L
S3
A5
SPLIT FACE CMU
A4
A4
2 LAYERS OF 2" SPRAY FOAM INSULATION
2" SPRAY FOAM INSULATION
2" SPRAY FOAM INSUL.
GWB
LT FIXT (SEE ELEC.);
T.O. FIXTS AT 8'-0" AFF TO
ALIGN W/ CMU COURSING
(TYPICAL)
FLASH TOP OF WING WALL
AS REQUIRED; SEE 2B/A3
8 x 16 SMOOTH FACED CMU
AT (BEHIND) LT FIXT MOUNT
PLATE (TYP.)
ELEV. = 90'-4"+/-
EXIST SLAB
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
BUILDING SECTION
7'- 0"
1'- 0"
7'- 4"
1'-6"
2" SPRAY FOAM
INSULATION
5/8" GWB
2" X2" STUD
10 3/4"
7 5/8" 3 1/8"
8" CMU
1 1/2" RIGID INSULAT'N
AIR & WATER BARRIER
1/2" OSB SHEATHING
1 1/2" RIGID INSULATION
AIR & WATER BARRIER
ROOF PLAN AND
BUILDING SECTIONSA4
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
KJH
CLZ
GJH
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
r
B r a n d y w i n e
C o m f o r t
S t a t i o n
C
U V
A D
R A
W I N
G S
C
U V
A A d w g
U
S E
R
C a r e
4 x 8 BLOCKING W/ ANCHOR
ROD; SEE STRUCT'L DTLS
8" CMU
2 x 10's AT 16" O.C.
ELEV. = 108'-8"
T.O. CMU
ELEV. = 100'-0"
T.O. EXIST. SLAB
2 x 2 STUDS AT
16" O.C. W/ 2" SPRAY
FOAM INSUL
ICE DAM BARRIER ON
3/4" SHEATHING
STANDING SEAM
METAL ROOF
EXIST. STRUCTURE
2 x 6 RAFTER TAILS
SISTERED TO RAFTERS
3'-0"
CEMENT BD EAVES
AND FASCIA; P-4
2'-0"
S3
EAVE VENT; 3 PER SIDE
FLASHING WITH DRIP
EDGE & WEEP HOLES
AT 24'' O.C. (TYP. AT
BASE OF CMU WALL)
ABUSE RESISTANT
GWB AT WALLS;
TYPICAL
GWB
ELEV. = 100'-0"
T.O. EXIST. SLAB
ELEV. = +/-107'-9" (F.VER)
T.O. WALL
2 x 6 STUDS AT 16" O.C.
1/2" SHEATHING
WIND/ WATER
BARRIER
CEMENT BD EAVES
5/8" FLOOR
SHEATHING
CORE DRILL FOR PLUMB'G
1/2" CEMENT BD
SUBSTRATE
6"+/-
CEMENT BOARD
LAP SIDING
BM BEYOND
CAST IN PLACE CONC; SEE STRUCT.
S.M. ALUM. COVERTO
4" BELOW GRADE
GRADE
SPRAY FOAM INSUL.
EXIST. CAST-IN-PLACE
CONC FOUNDATION
FLOOR LEVELER
TOPPING
2" RIGID INSUL. TO 4"
BELOW GRADE
1 1/2" RIGID INSUL.
1'- 2"
4"
2 x 4
CONT'S SPRAY
FOAM INSUL.
ABUSE RESISTANT
GWB (TYP @ WALLS)
GWB
4" SPAY FOAM
INSUL 2 x 8 BLOCKING
8" CMU
1/2" SHEATHING
ELEV. = 108'-8"
T.O. CMU
ELEV. = 100'-0"
T.O. EXIST. SLAB
2 x 6 STUDS AT
16" O.C. W/ 2" SPAY
FOAM INSUL
10"
CEMENT BOARD
LAP SIDING
EXIST. STRUCTURE
SEALANT
A6
1 1/2" RIGID INSUL
AT TISG
4" SPAY FOAM
INSUL
GWB
DRIP EDGE (TYP.)
FLASHING WITH
WEEP HOLES AT
24'' O.C. (TYP. AT
CMU WALL BASE)
CONTINUOUS 2"
SPRAY FOAM
INSULATION
ABUSE RESISTANT
GWB (TYP @ WALLS)
(3) 2 x 6 HEADER AT TISG
TRANSOM SHOWN DASHED;
SEE STRUCTURAL
ATTIC VENT; SEE ELEVATIONS
2 x 6 OUTLOOKERS AT 24" O.C.;
SEE STRUCTURAL DTLS
ELEV. = 108'-8"
T.O. CMU
ELEV. = 114'-0"
T.O. WALL/ B.O. COLLARS
2 x 8 BLOCKING
3/4" SHEATHING
2 x 6 STUDS AT 16" O.C.
CEMENT BOARD
LAP SIDING
CONTINUOUS
2" SPAY FOAM
INSUL
8" CMU
RIDGE BM BEYOND
ATTIC VENT; SEE ELEVATIONS
ELEV. = 108'-0"
B.O. TRUSS FRAME
8 x 8 CEDAR TRUSS
MEMBERS; SEE STRUCTURAL
6 x 10 CEDAR BM
BEYOND
8 x 8 CEDAR TRUSS
MEMBERS; SEE
STRUCTURAL
8 x 11 1/4 GLUE LAM
EXTER. BM BEYOND;
SEE STRUCTURAL
1'-0"
CL
2 x 6 OUTLOOKERS
AT 24" O.C.; SEE
STRUCTURAL DTLS
STL ANGLE SUPPORT
LEDGE; SEE STRUCT'L
(2) LAYERS 1" RIGID
INSUL
EXISTING CONC.
FOUNDATION WALL
CONC. APRON
BACKER ROD
AND SEALANT
TRENCH DRAIN;
SEE SPEC
B RAKE EDGE FLASHING DETAIL
RAKE FLASHING BY
STANDING SEAM
ROOFING
MANUFACTURER
CONTINUOUS CLEAT
CEMENT BD FASCIA
T & G CEDAR SOFFIT
ICE DAM BARRIER
ROOF SHEATHING
SHEET MTL. FLASHING W/
CONTINUOUS CLEAT
CEMENT BOARD SIDING
ON WALL SHEATHING
WIND/WATER BARRIER
RAFTER
STANDING SEAM
METAL ROOFING
4"SCALE: 3" = 1'-0" 2"0 8"
DETAILS
A ROOF EAVE FLASHING DETAIL
SHEET METAL RIDGE
FLASHING
STANDING SEAM METAL
ROOFING
ICE DAM BARRIER
3/4" OSB ROOF SHEATHING
RAFTER BEYOND
WALL SECTIONS AND
DETAILSA5
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
KJH
CLZ
GJH
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
r
B r a n d y w i n e
C o m f o r t
S t a t i o n
C
U V
A D
R A
W I N
G S
C
U V
A A d w g
U
S E
R
C a r e y
FINAL CONSTRUCTION DOCUMENTS
SCALE: 3/4" = 1'-0" 6" 0 18"6"
WALL SECTION
SCALE: 3/4" = 1'-0" 6" 0 18"6"
WALL SECTION
SCALE: 3/4" = 1'-0" 6" 0 18"6"
WALL SECTION
SCALE: 3/4" = 1'-0" 6" 0 18"6"
WALL SECTION
SCALE: 3/4" = 1'-0" 6" 0 18"6"
TRUSS SECTION
S3
SCALE: 3/4" = 1'-0" 6" 0 18"6"
APRON FROST LEDGE & TRENCH DRAIN DTL
SCALE: 1-1/2" = 1'-0" 8"4"0 16"
ROOF RIDGE DETAIL
NOTES
DOOR AND FRAME SCHEDULE
NO. SIZE TYPE MAT.
FRAME
TYPE MAT. DEPTH DETAILS SHEET
DOOR
GLASS
KEY
TYPE
HDWR
SET
FIRE
RATING
DOOR
HM HOLLOW METAL
DOOR AND FRAME SCHEDULE LEGEND
001 EXIST EXIST
101 3'-0" x 7'-0" x 1-3/4" DA HM F01 HM 5-3/4" 2 A6 -- -- 1 -- 1, 2 102 3'-0" x 7'-0" x 1-3/4" DA HM F01 HM 5-3/4" 2 A6 -- -- 1 -- 1, 2 103 3'-0" x 7'-0" x 1-3/4" DA HM F01 HM 5-3/4" 2 A6 -- -- 2 -- 1, 2
1. SEE 09 06 90 COLOR SCHEDULE
2. SEE HDWE SCHEDULE SPECIFICATIONS
DOOR AND FRAME SCHEDULE NOTES
DA
SCALE: 1/4" = 1'-0"
4' 2' 0 4'
DOOR TYPE
2" 5/8"
1/2
1/2
SE
E
SC
HE
D. 1 1 5/1
6" 1 1
5/1 6"
SCALE: 1/4" = 1'-0"
4' 2' 0 4'
HOLLOW METAL
FRAME PROFILE
FINISH FLOOR
F01
SEE SCHEDULE
SE
E
SC
HE
DU
LE
SCALE: 1/4" = 1'-0"
4' 2' 0 4'
HOLLOW METAL FRAME TYPE
SCALE: 1/4" = 1'-0"
4' 2' 0 4'
MEN
SCALE: 1/4" = 1'-0"
4' 2' 0 4'
WOMEN
1'-6"
M-1
SHELF &
BRACKET
1'-6"
1'-6" 1'-6"
A EAST B SOUTH
B SOUTH C WEST
PH-1
M-1
SHELF
M-1 20" x 36" MIRROR; 40" TO BOTTOM
HD-1 ELECTRIC HAND DRYER; 44" TO BOTTOM
PH-1 SURFACE MOUNTED DOUBLE ROLL PAPER HOLDER;
30" TO TOP
ND-1 SURFACE MOUNTED NAPKIN DISPOSAL; 30" TO TOP
GB-1 GRAB BAR SET = 2 WALL HORIZONTAL MOUNT UNITS
AND 1 VERTICAL UNIT; 34" TO CENTER:
REAR 36" (LOCATE EDGE CLOSEST TO WALL
CORNER 12" FROM WATER CLOSET CENTERLINE,
+/- 6" FROM WALL CORNER)
SIDE: 42" (LOCATE 12" MAX. FROM WALL CORNER)
VERTICAL 18" (LOCATE ABOVE HORIZONTAL GRAB
BAR 40" FROM WALL CORNER)
SD-1 SURFACE MOUNTED SOAP DISPENSER
BCS-1 BABY CHANGING STATION
TOILET ACCESSORY SCHEDULE
REFER TO SPECIFICATION SECTION 10 28 13
HD-1
HD-1
BCS-1
SLOPED
GWB CLG
SLOPED
GWB CLG
BCS-1
HD-1
FINISH FLOOR
F03
SCALE: 1/4" = 1'-0"
4' 2' 0 4'
INSULATED TRANSLUCENT FRAME TYPES
F02
ELEV. = 108'-9 1/2"
T.O. SILL
5'- 2 1
/2"
7'-6"+/- F. VERIFY7'-6"+/- F. VERIFY
HD-1
A EAST
C WEST
FIRE EXTINGUISHER CAB'T
AT N. SIDE OF WING WALL
FIRE EXTINGUISHER CAB'T
AT N. SIDE OF WING WALL
3'-0" 1"
3'-0"
1'-6"
GB-1
2'- 6"
1'-6" 3'-1" 3'-1" 3'-1"
5'-2"
GB-1
3'-1"+ 3'-0" 1"
5'-0" MIN.
1'- 5"
1'-6" 3'-1" 3'-1" 1'-6" 5'-1" MIN. 1'-6"
1'-6"
12'-3" (MIN.)
8'-1" (MIN.)9'- 3 1/2"+/-
PH-1
3'-1"3'-1"
SD-1
SD-1
MA
X.
A
LL
OW
AB
LE
SIM
PH-1 & ND-1
8 5
1. PROVIDE BLOCKING AT WALLS TO ANCHOR
URINAL AND TOILET PARTITIONS.
2. TOILET ACCESSORIES SHALL BE INSTALLED SO
THAT POSITION OF EACH ACCESSORY IS FULLY
COMPLIANT WITH ADA.
TOILET ACCESSORY SCHEDULE NOTES
SS TOILET PARTITIONS
TYPICAL, SEE SPEC
SS TOILET PARTITIONS; TYP
PE
R
MF
R
SEE TOILET ACCESSORY
SCHEDULE
SCALE: 3/4" = 1'-0"
2'1'0 4'
WALL TYPES
FINISH FLOOR
A1
FINISH FLOOR
B1
BOTTOM OF STRUCTURE
5/8" ABUSE RESISTANT GWB
EA. SIDE ON 2 x 4 STUDS
BOTTOM OF STRUCTURE
5/8" ABUSE RESISTANT
GWB ON 2" X 2" STUDS -
HOLD 1" FROM CMU
VINYL BASE
4 3/4"
ELEV. = 100'-0"
FINISH FLOOR
C1
SPRAY FOAM INSULATION
VINYL BASE VINYL BASE
4 3/4" 5/8" ABUSE RESISTANT GWB EA.
SIDE OF 2 x 4 STUDS
4 1/8"
5/8" GWB
2" SPRAY FOAM
BOTTOM OF STRUCTURE
FLASHING
1/4" GWB AT JAMB
1/2" SOLID SURFACE AT SILL
GWB
ALUMINUM FLASHING BY
TISG PROVIDER
DR & FRAME SCHEDULE,
FRAME TYPES & DTLS,
INT. ELEVS & WALL TYPESA6
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
KJH
CLZ
GJH
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
r
B r a n d y w i n e
C o m f o r t
S t a t i o n
C
U V
A D
R A
W I N
G S
C
U V
A A d w g
U
S E
R
C a r e y
FINAL CONSTRUCTION DOCUMENTS
4"
SCALE: 3" = 1'-0"
2"0 8"
JAMB DETAIL
ALUMINUM FLASHING BY
TISG PROVIDER
INSULATED TRANSLUCENT
WALL PANEL
Fi le n am e:
L
:\1 9-
B ra nd yw in e
C on fo rt
St at io n
(K H
A
S\ b1
9-
6s
.d w g
L as t p lo tte d:
4/
/2
:2
P ro j #
RJD
TJP
NRJ
31 MAR 2021
80070
BRANDYWINE FALLS COMFORT STATION UPGRADE
CUYAHOGA VALLEY NATIONAL PARK
BRECKSVILLE, OHIO
257393
A pr
2,
- 8
:2 9a m L
:\1 9-
Br an dy wi ne C on fo rt St at ion
(K
HA
)\S \ b
-0 s0
1.
dw g
- U
SE
R
To sh
FINAL CONSTRUCTION DOCUMENTS
FOUNDATIONS
F1. Subsoil investigations have not been made; therefore, the footings have been designed for the assumed bearing pressure specified below. The Contractor shall engage the services of a Geotechnical Engineer who shall conduct sufficient testing, including soil borings if necessary, to verify the adequacy of the foundation system shown and make recommendations on footing and slab subgrade preparation. If the foundation system shown is inappropriate, the Contractor shall notify the Architect who will then revise the design.
F2. The Geotechnical Engineer shall be retained for testing and observation during all earthwork and foundation construction phases to verify that the recommendations of the subsoil investigation are being implemented. The
Geotechnical Engineer shall inspect all footing excavations and slab subgrade immediately prior to placement of any concrete and shall test all fill for proper compaction.
F3. Bear footings on natural soils or suitable compacted fill materials. No footings shall be placed on frozen soils.
All footings have been designed for an allowable net bearing pressure of 1500 psf.
F4. The Contractor shall locate and protect any existing utilities from damage or interruption during construction.
CONCRETE AND REINFORCEMENT
C1. Concrete work shall conform to all requirements of ACI 301, "Specifications for Structural Concrete for
Buildings", except as modified by the Supplemental Requirements below.
C2. Submit a concrete mix design for each class of concrete for approval by the Project Engineer. The mix design shall include the proportions and test results or certifications for all components of the mix in accordance with the latest ACI 301. Submit documented results of “field test data” or “trial mixtures” in accordance with ACI 301 for each class of concrete to be used. The mix designs shall meet the following guidelines except as approved by the
Project Engineer.
C3. Use f'c = 4,000 PSI (L6.5) limestone concrete for structural concrete. Use f'c = 3,000 PSI (SG7.0) sand-gravel concrete for all masonry grouting and bond beam lintels. Design concrete mixes to the following specifications:
Cement per Water/ Air cu.yd. Cement Content Slump
Mix (min. sacks) (max. ratio) (%) (inches) L6.5 6 ½ 0.42 5-7 2-4
SG7.0 7 -- -- 8-10
* The Aggregate in mixes denoted as limestone concrete shall contain approximately 30 percent limestone by weight.
** Air entrainment shall not be used for interior slabs.
C4. The addition of water to the mix on site will not be allowed, unless specifically approved. Concrete may not be placed during freezing weather unless suitably protected, per ACI 306.1. Conform to ACI 305.1 for hot weather concreting.
C5. Cure concrete flatwork by moist cure or membrane forming curing compound for 72 hours.
C6. All reinforcing steel shall be ASTM A 615 grade 60.
C7. Provide lap splices as indicated below unless noted otherwise in details and schedules. Top bars are horizontal bars with more than 12-inches of fresh concrete cast below the bars in question.
Splice Length
Bar Size Top Bars All Other Bars #3 1'-4" 1'-1" #4 1'-10" 1'-5" #5 2'-3" 1'-9" #6 2'-8" 2'-1"
C8. Concrete cover of reinforcement shall conform to ACI 318-14 unless detailed otherwise.
C9. Submit reinforcing steel shop drawings indicating placement, spacing and lap lengths for review by the Project
Engineer.
C10. Welded wire fabric shall be flat sheets and shall conform to ASTM A 1064.
C11. Non-shrink grout shall be factory premixed as manufactured by L & M Chemicals, or equivalent.
C12. Expansion anchors shall be Hilti Kwik-Bolt 3, Red Head Trubolt or approved equivalent, with size as noted on the drawings. Install per manufacturer's instructions.
C13. Screw anchors shall be Hilti KWIK HUS-EZ, Red Head Large Diameter Tapcon, Simpson Titen HD, or approved equivalent, with size as noted on the drawings. Install per manufacturer's instructions.
C14. Adhesive anchors shall utilize Red Head “A7 Acrylic Adhesive” Anchor System. Simpson Strong-Tie
“Acrylic-Tie” and “Epoxy-Tie” anchor systems or Hilti “HIT HY-200” and “HIT-RE 500-SD” systems are also acceptable provided their shear and tension allowable load capacities are equivalent to or greater than Red Head A7
Acrylic Adhesive. Threaded rods shall be ASTM A193 Grade B7 unless noted otherwise. For threaded rods into masonry, use Hilti “HIT HY-70” adhesive. Installation of anchors shall be in strict accordance with manufacturer's recommendations including finish, minimum embedment, adhesive types, recommended accessories for base conditions (such as screens at hollow base conditions) and cure times for weather conditions.
C15. Deformed bar anchors shall conform to ASTM A 496.
C16. Portland cement shall conform to ASTM C150, type I.
C17. Air-entraining admixtures shall conform to ASTM C260. Other admixtures, if used, shall conform to ASTM C494.
C18. Any horizontal construction joints in concrete pours not shown on the drawings shall be submitted to the
Structural Engineer for review.
CONCRETE MASONRY
M1. Masonry units shall conform to ASTM C 90. Minimum compressive strength of individual units shall be
2,000 PSI on the net area of the block. Design compressive strength of masonry, f'm = 2,000 PSI.
M2. Mortar shall conform to ASTM C 270 type S.
M3. Furnish equipment and materials and perform all labor necessary to build concrete masonry, complete, as shown on the drawings.
M4. Grout for bond beams and for filling vertically reinforced masonry cells shall comply with cast-in-place concrete specifications and shall be well consolidated by rodding or vibrating. Grout by low-lift method with a maximum grout height of 4'-8".
M5. Reinforce all masonry horizontally with galvanized 9 gage Durowal at 16 inches on center. Reinforce walls vertically as shown on the drawings. Lap splice vertical reinforcing as shown on the drawings.
M6. Masonry may not be laid during freezing weather unless suitably protected. Conform to "Recommended
Practice for Cold Weather Masonry Construction" by the International Masonry Industry All-Weather Council.
M7. The contractor shall provide all temporary shoring necessary to laterally support all masonry walls.
M8. All openings required in masonry walls greater than 8 inches wide shall be placed at the time of wall construction. The Contractor shall contact the Structural Engineer if openings greater than 8 inches wide are required after the walls have been constructed. Do not place any duct openings directly below beam bearing locations unless specifically shown on the drawings.
M9. Shore steel lintels if required during construction to prevent rotation due to eccentric loads.
STRUCTURAL STEEL
S1. All channels, angles, bars and plates shall conform to ASTM A 36 (Fy = 36 ksi).
S2. Tube sections shall conform to ASTM A 500 Grade B (Fy = 46 ksi).
S3. Pipe sections shall conform to ASTM A 53 Grade B (Fy = 35 ksi) or ASTM A500 Grade B (Fy = 42 ksi).
S4. Anchor rods shall conform to ASTM A 36 or ASTM F 1554, Grade 36 unless indicated otherwise. All nuts used with anchor rods shall be heavy hex head conforming to ASTM A 563.
S5. Welding shall be performed by certified welders using low hydrogen E70 electrodes. Comply with AWS for electrodes and procedures.
S6. All steel shall be prime painted with TNEMEC 10-1009 or equivalent, except steel permanently exposed shall be painted with two coats of TNEMEC 90-97. Galvanize exterior lintel members in contact with masonry.
S7. Anchor rods, nuts, and washer plates in contact with preservative treated lumber shall be G90 hot-dip galvanized.
STRUCTURAL LUMBER AND CARPENTRY
L1. All stress grades and stress criteria shall be based on the National Design Specifications for Wood
Construction, 2015.
L2. Lumber for 2x8's and larger shall be No. 2 and better Hem-Fir, Spruce-Pine-Fir, or Doug Fir-Larch.
L3. Lumber for 2x4's, 2x6's, 4x4's and 6x6's shall be Stud grade (or better) Hem-Fir or Spruce-Pine-Fir.
L4. Where rectangular wood beams are specifically noted to be Structural Composite Lumber (SCL), they shall be laminated veneer lumber or parallel strand lumber, meeting the following criteria:
Minimum allowable stresses
Extreme fiber in bending Fb = 2,800 psi
Horizontal shear Fv = 285 psi
Modulus of elasticity E = 2,000,000 psi
L5. All framing lumber shall be stamped with grade and trademark for each piece.
L6. All lumber shall have a maximum moisture content of 19% and shall be smooth on 4 sides.
L7. Pressure treat sill plates, blocking, furring, and similar items in direct contact with masonry or concrete or use redwood.
L8. Roof sheathing shall be APA Rated Sheathing, plywood or OSB, Exposure 1, 19/32 Performance Category, with 40/20 Span Rating. Use ply clips at all unsupported edges.
L9. Wall sheathing at exterior walls and indicated interior shear walls shall be APA Rated Sheathing, plywood or
OSB, Exposure 1. Use 7/16 performance category with 24/16 Span Rating or 15/32 Performance Category with
32/16 Span Rating.
Installation:
L10. Standards: except as otherwise noted, comply with "Manual of House Framing" by National Forest Products
Association, including nailing, fire stopping, anchorage, framing and bracing.
L11. Unless specifically noted otherwise, nail plywood or OSB roof sheathing at 6 inches on-center at edges of panels and 12 inches on-center at intermediate supports with 8d nails (0.131” diameter x 2” min. length) with a minimum of 1 3/8-inch penetration. Leave 1/8 inch spacing at all ends and edges. Apply with the plywood perpendicular to the joists. Nails of different type, diameter, or length shall be submitted to the structural engineer for approval.
L12. Unless specifically noted otherwise, nail plywood or OSB wall sheathing at 6 inches on-center at edges of panels and 12 inches on-center at intermediate supports with 8d nails (0.131” diameter x 1 7/8” min. length) with a minimum of 1 3/8-inch penetration. All panel edges shall be blocked with 2-inch nominal or wider material. Leave
1/8 inch spacing at all ends and edges. Nails of different type, diameter, or length shall be submitted to the structural engineer for approval.
L13. All vertical joints of panel sheathing shall occur over, and be fastened, to common studs. At Contractor option, vertical joints of panel sheathing shall be permitted to occur over double studs where adjoining panel edges are attached to separate studs with the required panel edge fastening and adjacent studs attached together with (2) rows
10d box nails (3”x0.128”) at 6”o.c.
L14. All metal hangers and connectors shall be manufactured by Simpson or approved equivalent and be size and type recommended for the application by the manufacturer.
L15. All metal hangers, connectors, and fasteners in contact with preservative treated wood shall be stainless steel or G185 hot-dip galvanized. Fasteners shall be compatible with hangers and connectors. Do not mix stainless steel with galvanized steel.
L16. Bed all sills and plates resting on masonry or concrete on a sill sealer strip.
L17. Solid joists having spans more than 8 feet shall be rigidly braced with continuous rows of bridging at intervals not exceeding 8 feet.
L18. Use triple 2x studs at all exterior wall corners unless shown otherwise.
L19. All headers and built-up beams shall be glued with PL400 and nailed at 8" o.c. staggered both side's w/16d nails (0.162” x 3 ½”).
L20. Under built-up wood beams provide built-up columns with at least the same number of 2x's as contained in the built-up beam. Built-up wood columns shall be glued with PL400 and nailed at 8 inches on-center.
L21. Unless detailed or shown otherwise, provide the following minimum header sizes:
Wall Opening Width Header Size
Up to 4'-6" (2) - 2 x 8's
4'-6" to 5'-6" (2) - 2 x 10's
5'-6" to 6'-6" (2) - 2 x 12's
L22. Framing plans show primary framing members, sizes and supports. Framer shall provide and install all framing required (whether specifically shown or not) for headers, nailers, corners, partition supports, roof crickets, ceiling joists, stairs, bridging, etc. to make a complete and sound installation in accordance with all applicable codes.
GLUED-LAMINATED TIMBER
GL1. When rectangular wood beams or wood deck are specifically noted to be glued-laminated (G.L.), they shall conform to this section of the General Notes.
GL2. AITC 117 “Standard Specifications for Structural Glued Laminated Timber” and ANSI/AITC A190.1
“Structural Glued Laminated Timber”.
GL3. Glued Laminated Beams shall be “Architectural” appearance grade, AC/AC (Alaskan Cedar) combination
22F-V3, with the following minimum allowable properties:
Fbxx -
Tension Zone Stressed in Tension = 2200 psi
Compression Zone Stressed in Tension = 1100 psi
Fvxx = 165 psi
E = 1,700,000 psi
PREFABRICATED WOOD TRUSSES
WT1. Prefabricated wood trusses and connections thereof shall be designed, fabricated and installed in accordance with the National Design Specification and Truss Plate Institute publications TPI1, TPI DSB-89, and TPI HIB-91.
WT2. Design 8x8 cedar timber trusses for the following loads plus the self-weight of the truss:
Ridge Beam Reaction DL = 1.6 kips
Roof LL = 2.0 kips
Eave Beam Reactions DL = 1.0 kip
Roof LL = 1.0 kips
WT3. Connections shown are for general appearance. Fabricator shall design the connections for the loads above and adjust bolts and plates to meet appearance approved by the Architect/Engineer.
WT4. The truss manufacturer, subject to approval by the Architect, may alter truss layouts and geometry shown.
Submit any proposed changes on the shop drawings.
WT5. Truss manufacturer shall submit as shop drawings a complete erection drawing and engineering calculations for all trusses. A registered engineer in the State of Ohio shall stamp the calculations. The calculations shall be presented in a logical and orderly manner and shall be keyed to the erection plans. The erection plans shall include a complete layout plan of all trusses, with the trusses labeled using the same designations as the calculations. The truss layout plans shall dimension truss spacing and shall show the location of any concentrated loads. Any required hangers for concentrated loads shall be called for on the erection plans. Truss manufacturer shall design/detail all beam to truss connections. Required truss bridging and erection bracing shall be designated on the erection drawings.
EXISTING CONSTRUCTION
EX1. Guard against movement or settlement of the existing structure. Provide bracing or shoring as necessary in connection therewith. Be responsible for safety and support of the structure during all phases of the construction.
EX2. If during construction, movements or settlements of significant nature are observed, take precautions as necessary to secure the safety of the subject and/or adjoining premises, and contact the Architect.
EX3. The existing information shown on the drawings is as exact as could be secured insofar as building construction and existing conditions are concerned. Extreme accuracy is not guaranteed. The drawings and specification are intended for the assistance of the Contractor in achieving the end results. Many of the dimensions and conditions noted on the drawings are based on information obtained from the original drawings and may or may not be correct. Exact locations, measurements, distances, levels, etc. will be governed by conditions at the job site.
The Contractor shall field verify all existing conditions and dimensions…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .