Structural_Drawings_-_Daytona_Beach_Main_Street_Pier_Repairs_-2026_-_Signed.pdf
PDF 3 MB Posted
- Attached to
- 2620ITB - Main Street Pier Repairs - 2026
- Solicitation number
- 2620ITB
- Issued by
- Volusia County, Florida
About this file
This is a set of structural drawings and specifications for the City of Daytona Beach Main Street Pier Repairs project scheduled for 2026. The project encompasses comprehensive repairs to the existing pier structure located in Daytona Beach, Florida, involving concrete and wood framing work. The drawings detail formwork design, reinforcing steel placement, concrete protection requirements, and wood framing specifications in accordance with ACI standards, Florida Building Code 2023, and industry best practices. Key structural specifications include 5,000 PSI concrete strength with Type II cement, Grade 60 reinforcing steel, Southern Yellow Pine lumber with pressure treatment requirements, and stainless steel fasteners throughout. The contractor must verify existing conditions through site visits, submit shop drawings and specifications for engineer review prior to fabrication, conduct a pre-construction meeting with the engineer, and provide 48-hour advance notice before structural work observation. A non-mandatory pre-bid conference will be conducted via Teams, with question submissions accepted through the City's procurement platform at https://procurement.opengov.com/portal/codb until the deadline specified in the solicitation timeline.
The project requires contractors to comply with all applicable federal, state, and local codes and regulations, with responsibility for means, methods, job site safety, and coordination with building operations. All concrete testing will be performed by the owner's testing laboratory, and contractors must submit specifications for all materials used and obtain engineer approval before proceeding. The contractor bears responsibility for verifying the extent of repair work prior to bidding, managing demolition and disposal of existing damaged materials, and repairing any damage caused by construction activities. Wind load design is based on ultimate wind speed of 140 MPH with exposure category D, and the structure must accommodate design loads including 100 PSF deck live load and 50 PLF uniform top rail loads. All submittals must be reviewed and stamped by the contractor before engineer review, with the understanding that engineer checking does not relieve the contractor of responsibility for deviations or errors. Fire protection systems must remain operational throughout the repair period.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. FORMWORK SHALL BE DESIGNED IN ACCORDANCE WITH THE ACI "MANUAL OF CONCRETE
PRACTICE", LATEST EDITION.
2. REINFORCING STEEL SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH THE ACI "MANUAL
OF CONCRETE PRACTICE", LATEST EDITION, UNLESS OTHERWISE NOTED.
3. PROVIDE COLUMN AND WALL DOWELS OF THE SAME SIZE AND NUMBER AS THE RESPECTIVE
COLUMN AND WALL REINFORCING UNLESS OTHERWISE DETAILED.
4. PROVIDE TWO #4 BARS AS STIRRUP CARRY BARS WHERE NO TOP STEEL IS AVAILABLE TO HOLD
STIRRUPS.
5. WHEREVER AN APPROVED PIPE OR CONDUIT EXTENDS THROUGH A BEAM, PROVIDE ONE
ADDITIONAL STIRRUP ON EACH SIDE OF THE OPENING.
6. CONCRETE PROTECTION FOR REINFORCING BARS SHALL BE IN ACCORDANCE WITH THE
"BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE", ACI 318-19.
7. CONTRACTOR SHALL NOTIFY THE ENGINEER AT LEAST 24 HOURS PRIOR TO PLACING
CONCRETE.
8. CONSTRUCTION JOINTS IN BEAMS, JOISTS OR SLABS TO BE LOCATED BETWEEN THE 1/4 POINT
AND CENTERLINE OF SPAN, OR AS DIRECTED BY THE ENGINEER.
9. DO NOT PLACE OR CUT HOLES IN CONCRETE SLABS, BEAMS, WALLS OR COLUMNS WITHOUT
PRIOR APPROVAL OF THE ENGINEER.
10. EXTERIOR EXPOSED CONCRETE SHALL BE AIR-ENTRAINED. AIR CONTENT SHALL BE 6 PERCENT
(+/-1 1/2 PERCENT).
11. CAMBER CONCRETE MEMBERS FOR DEAD LOAD DEFLECTION BY ADJUSTING FORMS.
12. PIPES AND CONDUITS EMBEDDED IN OR PASSING THROUGH STRUCTURAL MEMBERS MUST BE
APPROVED BY THE STRUCTURAL ENGINEER. PIPE AND CONDUITS EMBEDDED IN CONCRETE
SHALL NOT BE LARGER THAN 2 INCHES IN OUTSIDE DIAMETER AT THEIR WIDEST POINT OR
FITTING OR 1/3 OF THE THICKNESS OF THE SLAB, BEAM OR WALL.
13. ELECTRICAL CONDUIT OR PIPES EMBEDDED IN OR PASSING THROUGH SLABS, BEAMS OR WALLS
SHALL BE LOCATED AND PLACED SO THAT:
A. THEY ARE NOT CLOSER THAN THREE DIAMETERS ON CENTER.
B. THE CONCRETE COVER IS NOT LESS THAN 2 INCHES.
C. THEY RUN BETWEEN REINFORCING AND DO NOT DISPLACE IT IN ANY MANNER.
14. ALUMINUM CONDUITS SHALL NOT BE PLACED IN CONCRETE.
15. CHAMFER ALL EXPOSED CONCRETE CORNERS. SEE ARCHITECTURAL/STRUCTURAL DRAWINGS
FOR REQUIREMENTS.
16. CONCRETE SHALL BE TESTED BY THE OWNER’S TESTING LAB. REFER TO SPECIFICATIONS FOR
REQUIREMENTS.
17. PROPER CURING PROCEDURES SHALL BE USED FOR SLAB ON GRADE TO PREVENT CURLING.
18. CALCIUM CHLORIDE SHALL NOT BE USED IN CONCRETE MIXES.
19. ALL CONCRETE SHALL CONTAIN CRYSTALLINE ADMIXTURE THAT CAUSES CONCRETE TO BE
SEALED AGAINST PENETRATION OF WATER. PRODUCT SHALL BE XYPEX CHEMICAL
CORPORATION, XYPEX ADMIXTURE, 3 PERCENT BY WEIGHT OF CEMENT CONTENT, OR
APPROVED EQUIVALENT. COMPLY WITH RECOMMENDATIONS OF MANUFACTURER.
1. CONSTRUCTION AND DESIGN OF ALL WOOD FRAMING SHALL CONFORM TO THE NATIONAL
FOREST PRODUCTS ASSOCIATION DESIGN SPECIFICATIONS, AMERICAN PLYWOOD ASSOCIATION,
NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION, AND THE STATE OF FLORIDA
BUILDING CODE, LATEST EDITIONS.
2. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE DRAWINGS OF ALL
OTHER DISCIPLINES AND THE SPECIFICATIONS. THE CONTRACTOR SHALL VERIFY THE
REQUIREMENTS OF OTHER TRADES AS TO SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS,
HOLES, AND OTHER ITEMS TO BE PLACED OR SET IN THE STRUCTURAL WORK.
3. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT
TO APPROVAL BY THE ENGINEER.
4. TIMBER:
A. ALL STRUCTURAL SYSTEMS RELATING TO WOOD FRAMING WHICH ARE TO BE COMPOSED OF
COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING
MANUFACTURING, DELIVERY, HANDLING, STORAGE, AND ERECTION IN ACCORDANCE WITH
THE SUPPLIER’S INSTRUCTIONS AND REQUIREMENTS.
B. SOUTHERN YELLOW PINE (SYP) LUMBER:
JOISTS: SYP SELECT STRUCTURAL GRADE
GUARDRAIL POSTS: SYP No. 1 GRADE OTHER SAWN LUMBER: SYP No. 2 GRADE
SOUTHERN PINE TREATED ROUND TIMBER: PILE GRADE IN ACCORDANCE WITH ASTM D25
DECKING: MARINE-GRADE 2X8 BY LUMBEROCK (OR APPROVED EQUAL)
C. ALL RAMPS ESTABLISHED WITHIN THE WOODEN DOCK SECTIONS SHOULD BE ESTABLISHED TO
ADA REQUIREMENTS. SLOPES MUST NOT EXCEED 1:12 (V:H) AND HANDRAILS MUST BE
ESTABLISHED ON BOTHSIDES OF THE RAMP ACCORDING THE TYPICAL SECTION FOUND IN
PLANS. TRANSITION OF THE WOODEN ACCESS RAMPS SHOULD BE FLUSH WITH THE DECK AND
A MINIMUM CLEARANCE OF 36" OF SPACE SHOULD BE BETWEEN HANDRAILS.
D. ALL STRINGERS, PILE CAP BOARDS OR OTHER TIMBER COMPONENTS NOT WITHIN THE
WALKWAYS SHALL BE SYP No. 2 GRADE.
E. TREATMENT OF TIMBER SHALL BE AS FOLLOWS: HANDRAILS AND DECKING -0.25 PCF CCA
(COPPER CHROMIUM ARSENATE), STRINGERS, PILE CAP BOARDS AND OTHER COMPONENTS
EXCEPT PILING -0.6 CCA, PILINGS/POSTS -2.5 CCA. IF REQUIRED BY THE OWNER OR LOCAL
AGENCY, TREATMENT SHALL BE EQUIVALENT LEVELS OF ACQ (ALKALINE COPPER
QUATEMARY). REFER TO TIMBER SUPPLIER FOR EQUIVALENT ACQ LEVELS OF PROTECTION.
F. DECKING SHALL BE PLACED WITH 1/4 INCH GAPS BETWEEN BOARDS.
G. ONE LAYER OF ROOFING FELT SHALL BE PLACED BETWEEN DECK (EACH ONE) AND
STRINGERS.
H. ALL BOARDS FOR DECKING SHALL BE INSTRALLED CROWN DOWN.
5. LOADING APPLIED TO THE STRUCTURE DURING THE PROCESS OF CONSTRUCTION SHALL NOT
EXCEED THE SAFE LOAD-CARRYING CAPACITY OF THE STRUCTURAL MEMBERS. THE LIVE LOADS
USED IN THE DESIGN OF THIS STRUCTURE ARE INDICATED IN THE “DESIGN SPECIFICATIONS”. DO
NOT APPLY ANY CONSTRUCTION LOADS UNTIL STRUCTURAL FRAMING IS PROPERLY CONNECTED
TOGETHER AND UNTIL ALL TEMPORARY BRACING IS IN PLACE.
6. NAILING OF GUARDRAIL SHEATHING SHALL BE:
8d AT 6 INCHES ON CENTER AT PANEL EDGES
8d AT 12 INCHES ON CENTER AT INTERMEDIATE FRAMING MEMBERS
7. INSTALL ALL SHEATHING WITH THE LONG DIMENSIONS OF THE PANEL ACROSS SUPPORTS AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS. STAGGER PANEL END JOINTS. ALLOW 1/8-
INCH SPACING AT PANEL ENDS AND EDGES UNLESS OTHERWISE RECOMMENDED BY THE
SHEATHING MANUFACTURER.
8. ALL NAILING SHALL BE CAREFULLY DRIVEN AND NOT OVERDRIVEN. THE USE OF STAPLES IS
PROHIBITED.
9. BOLTS, SCREWS, AND NAILS:
A. ALL FASTENERS, INCLUDING NAILS, SCREWS, THREADED RODS, BOLTS, NUTS, WASHERS,
PLATES, LAGS, ETC. SHALL BE GRADE 316 STAINLESS STEEL (SS). WASHERS USED WITH
SINGLE-BOLTED OR DOUBLE-BOLTED CONNECTIONS (FOR EXAMPLE: STRINGER TO PILING
CONNECTION, CAP BOARD CONNECTIONS OR CROSS-BRACING) SHALL BE MINIMUM 3-INCH
DIAMETER "DOCK WASHERS". STANDARD WASHERS FOR SPLICE BLOCK AND RAILINGS.
B. BOLTS SHALL BE EXTENDED FULLY THROUGH THE NUTS BUT NOT EXTEND BEYOND THE NUT
MORE THAN 1/2 INCH.
C. STAINLESS STEEL (SS) SCREWS AS SHWON IN PLANS.
10. HURRUCANE STRAPS AND HANGER:
A. SIMPSON STRONG TIE TWIST STRAPS (STAINLESS STEEL HURRICANE STRAPS), HTSQ20SS-
SDS.
B. EIGHT (8) TOTAL SCREWS, HALF STRINGERS AND HALF CAP BOARDS. SCREWS SHALL BE
SIMPSON STRONG TIE 1/4"X1 1/2" SDS, STAINLESS STEEL.
C. UNO, HANGER CONNECTION SHALL DEVELOP THE SHEAR STRENGTH OF THE BEAM AND JOIST.
11. WOOD MEMBERS BEARING ON CONCRETE AND MASONRY WALLS SHALL HAVE 1/2-INCH AIR
SPACES AROUND SIDES AND ENDS OF MEMBERS. BEAM ENDS SHALL HAVE THE TOP CORNERS
NOTCHED TO ALLOW BEAMS TO FALL OUT OF BEARING POCKETS FREELY IN THE EVENT OF FIRE
COLLAPSE.
12. NAILING OF WOOD FRAMING MEMBERS SHALL CONFORM TO THE MINIMUM NAILING SCHEDULE.
13. ALL FRAMING EXPOSED TO THE WEATHER OR IN CONTACT WITH MASONRY OR CONCRETE SHALL
BE PRESSURE-TREATED IN ACCORDANCE WITH THE AMERICAN WOOD PRESERVERS
ASSOCIATION SPECIFICATIONS. WHERE POSSIBLE, ALL CUTS AND HOLES SHOULD BE COMPLETED
BEFORE TREATMENT. CUTS AND HOLES DUE TO THE ON-SITE FABRICATION SHALL BE BRUSHED
WITH 2 COATS OF COPPER NAPHTHENATE SOLUTION CONTAINING A MINIMUM OF 2% METALLIC
COPPER IN SOLUTION (PER AWPA STANDARD M4).
14. PREFABRICATED METAL JOIST HANGERS, HURRICANE CLIPS, HOLD-DOWN ANCHORS, SELF-
DRILLING SCREWS, AND OTHER ACCESSORIES SHALL BE AS MANUFACTURED BY “SIMPSON
STRONG-TIE COMPANY” OR APPROVED EQUAL. INSTALL ALL ACCESSORIES PER THE
MANUFACTURER’S REQUIREMENTS. ALL STEEL SHALL HAVE A MINIMUM THICKNESS OF 0.04
INCHES (PER ASTM A653) AND BE GALVANIZED (G60 COATING) OR STAINLESS STEEL, TYPE 316 AS
SPECIFIED.
15. ALL JOISTS SHALL BE POSITIONED WITH THE NATURAL CAMBER TURNED UP.
1. DIMENSIONS OF EXISTING CONSTRUCTION OR CONSTRUCTION IN PROGRESS SHALL BE
VERIFIED AND COORDINATED PRIOR TO FABRICATION OF STRUCTURAL COMPONENTS.
2. VERIFY AND COORDINATE, WITH ALL CONTRACTORS, THE LOCATION OF ALL ARCHITECTURAL
AND MECHANICAL APPURTENANCES AND OPENINGS.
3. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION DRAWINGS FOR
ADDITIONAL INFORMATION.
4. EXPANSION ANCHORS SHALL BE HILTI KWIK BOLT 3.
5. ADHESIVE ANCHORS SHALL BE HILTI HIT-HY 200.
6. SLEEVE ANCHORS SHALL BE HILTI HLC.
7. SCREW ANCHORS SHALL BE HILTI KWIK HUS.
8. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR THE FOLLOWING ITEMS PRIOR TO
FABRICATION: STRUCTURAL CONCRETE, REBAR REINFORCEMENT, CONCRETE MIX DESIGN,
WOOD STUDS AND JOISTS.
9. THE CONTRACTOR MUST SUBMIT SPECIFICATIONS FOR ALL THE MATERIAL BEING USED IN THIS
PROJECT FOR THE ENGINEER’S REVIEW.
DESIGN WIND PRESSURE (CLEAR WIND FLOW), PSF
EFFECTIVE WIND AREA, SF
AREAS DESCRIPTION≤25 >25, ≤ 100
INTERIOR REGION OF THE BOARDWALK
ZONE 3 (+)
NOTES:
1. RAIL AND PARAPET WIND PRESSURE: +72/-72 PSF.
2. NEGATIVE PRESSURES ACT AWAY FROM COMPONENT SURFACE. POSITIVE PRESSURES ACT TOWARD COMPONENT SURFACES.
3. WIND PRESSURES SHOWN IN THIS TABLE ARE ULTIMATE PRESSURES OBTAINED VIA ASCE 7-22.
MULTIPLY BY 0.6 TO GET SERVICE WIND PRESSURES.
3 1
2 3
+95
T Y
P
IC
A L
T Y
P
IC
A L
TYPICAL
5'-0"
GENERAL ROOF PLAN
> 100
ZONE 3 (-)
ZONE 2 (+)
ZONE 2 (-)
ZONE 1 (+)
ZONE 1 (-)
-131
+71
-68
+48
-44
+71
-68
REGION OF THE BOARDWALK SURFACE LOCATED
WITHIN 5'-0" OF THE BOARDWALK EDGES
TYPICAL
5'-0"
REGION OF THE BOARDWALK LOCATED WITHIN 5'-0"
AND 10'-0" OF THE BOARDWALK EDGES
+71
-68
+48
-44
+48
-44
+48
-44
+48
-44
1. TO THE BEST OF OUR KNOWLEDGE, THE STRUCTURAL DRAWINGS AND SPECIFICATIONS COMPLY
WITH THE APPLICABLE REQUIREMENTS OF THE GOVERNING BUILDING CODE.
2. CONSTRUCTION IS TO COMPLY WITH THE REQUIREMENTS OF THE GOVERNING BUILDING CODE AND
ALL OTHER APPLICABLE FEDERAL, STATE, AND LOCAL CODES, STANDARDS, REGULATIONS AND
LAWS.
3. THESE DRAWINGS ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT AND SCOPE OF WORK.
THESE DRAWINGS ARE NOT INTENDED TO BE SCALED FOR MEASUREMENTS, OR TO SERVE AS SHOP
DRAWINGS.
4. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUCTED TO APPLY ANY SIMILAR SITUATION ELSEWHERE IN THE PROJECT, EXCEPT WHERE
A DIFFERENT DETAIL IS SHOWN.
5. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL VERIFY IN THE FIELD ALL DIMENSIONS, ELEVATIONS, CONNECTIONS, AND ALL EXISTING CONDITIONS. NOTIFY ENGINEER OF ANY
DISCREPANCY PRIOR TO PROCEEDING WITH FABRICATION OR INSTALLATION. DIMENSIONS OF
EXISTING STRUCTURES ARE PROVIDED FOR INFORMATION AND ILLUSTRATION PURPOSES ONLY. IF
CONFLICTS OCCUR IN OR BETWEEN DOCUMENTS AND FIELD CONDITIONS OR OTHERWISE THE
CONTRACTOR SHALL IMMEDIATELY CONTACT THE ENGINEER FOR CLARIFICATION AND DIRECTION
BEFORE PROCEEDING WITH THE WORK.
6. EVERY REASONABLE EFFORT HAS BEEN MADE TO VERIFY EXISTING CONDITIONS AND REPRESENT IN PLANS THE STRUCTURAL DAMAGE. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXTENT OF REPAIR WORK PRIOR TO BIDDING. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SUBSEQUENT
OR INCIDENTAL WORK REQUIRED TO PROPERLY INSTALL ALL NEW WORK INDICATED OR
REASONABLY INFERRED FROM THE DRAWINGS.
7. IF ANY ERRORS OR OMISSIONS APPEAR IN THE DRAWINGS THE CONTRACTOR SHALL NOTIFY THE
ENGINEER IN WRITING OF SUCH OMISSION OR ERROR PRIOR TO PROCEEDING WITH ANY WORK
WHICH APPEARS TO BE IN QUESTION.
8. CONTRACTOR SHALL VISIT THE SITE AND EXAMINE THE EXISTING STRUCTURE, SURFACES,
CONDITIONS & EXTENT OF WORK INVOLVED. AFTER EXAMINATION, A WORK SCHEDULE SHALL BE PREPARED AND SUBMITTED IN WRITING TO THE OWNER AND THE ENGINEER FOR THEIR APPROVAL
PRIOR TO COMMENCEMENT OF ANY WORK.
9. PRIOR TO STARTING WORK, THE CONTRACTOR SHALL CONDUCT A MEETING WITH THE ENGINEER TO
VERIFY EXISTING CONDITIONS AT EACH AREA AFFECTED AND DISCUSS THE PROCEDURES AND
SEQUENCE FOR THE ANTICIPATED REPAIR SOLUTIONS.
10. THE CONTRACTOR SHALL NOTIFY THE ENGINEER 48 HOURS IN ADVANCE TO OBSERVE THE WORK AS
REQUIRED BY THE OWNER, ENGINEER OR BUILDING DEPARTMENT. CONTRACTOR SHALL VERIFY
THAT EACH AND EVERY STRUCTURAL ITEM HAS BEEN ACCEPTED BY THE INSPECTOR PRIOR TO
PROCEEDING WITH SUBSEQUENT WORK AND/OR CONCEALING ANY STRUCTURAL ITEM. ANY
STRUCTURAL ITEM WHICH HAS NOT BEEN SPECIFICALLY ACCEPTED BY THE INSPECTOR AND/OR ANY
CONCEALING CONSTRUCTION COULD BE SUBJECT TO REMOVAL AND RECONSTRUCTION.
11. ANY EXISTING ACTIVE UTILITY SERVICE LINES, INDICATED OR NOT, SHALL BE PROTECTED FROM DEMOLITION OR DAMAGE. PRIOR TO DISCONNECTING ANY UTILITY SERVICE LINE IF NECESSARY, NOTIFY THE OWNER AND COORDINATE THE TIME WITH THE OWNER SCHEDULE.
12. THE CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS AND JOB SITE SAFETY,
COORDINATION WITH BUILDING OPERATIONS, MAINTENANCE OF TRAFFIC, AND CONSTRUCTION
PROCEDURES.
13. EXISTING STRUCTURE WHERE FOUND DAMAGED AND NOT EXPLICITLY REQUIRED TO BE REPAIRED
BY THESE PLANS SHALL BE REPAIRED AT THE ENGINEER'S DIRECTION.
14. CONTRACTOR TO EXECUTE ALL REPAIR WORK IN AN ORDERLY AND CAREFUL MANNER WITH DUE
CONSIDERATION FOR ANY EXISTING STRUCTURE/SURFACES. EXTREME CAUTION SHALL BE
EXERCISED TO ENSURE THAT NO DAMAGE OCCURS TO ANY OF THE EXISTING
STRUCTURE/SURFACES TO REMAIN. IF ANY MEMBER/SURFACE BECOMES DAMAGED DUE TO
CONSTRUCTION ACTIVITY, THE DAMAGED MEMBER/SURFACE SHALL BE REPAIRED/REPLACED AT THE
CONTRACTOR’S OWN EXPENSE.
15. CONTRACTOR TO REMOVE ITEMS AS REQUIRED TO ACCOMMODATE ADJACENT WORK. REINSTALL AFTER COMPLETION OF CONSTRUCTION ACTIVITIES TO A CONDITION ACCEPTABLE TO THE OWNER
AND ENGINEER.
16. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROPERLY DISPOSE DEMOLISHED MATERIALS. UPON
COMPLETION OF REPAIR WORK, ADJACENT AREAS AND PROPERTY SHALL BE LEFT CLEAN AND
SATISFACTORY TO THE AUTHORITIES HAVING JURISDICTION, THE OWNER, AND THE ENGINEER. ANY AND ALL DAMAGES TO BUILDING SURFACES, EQUIPMENT, ETC. CAUSED DURING PERFORMANCE OF
WORK SHALL BE THE RESPONSIBILITY OF CONTRACTOR TO REPAIR TO ORIGINAL CONDITIONS.
17. ANY UNFAVORABLE CHANGES IN THE WORKING CONDITIONS FROM THOSE IDENTIFIED IN THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE REPORTED TO THE STRUCTURAL
ENGINEER FOR THE VERIFICATION BEFORE PROCEEDING WITH THE WORK.
18. CONTRACTOR MAY, FOR HIS OWN CONVENIENCE, AT NO ADDITIONAL COST TO THE OWNER,
PROPOSE A DIFFERENT SOLUTION/MATERIALS TO THOSE SHOWN IN THE PLANS. ALL
SOLUTIONS/MATERIALS MUST BE SUBMITTED TO THE ENGINEER FOR APPROVAL. SEE NOTE 3 ON
SHOP DRAWING SECTION. CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS AND
CALCULATIONS FOR ANY PROPOSED SOLUTION THAT MAY REQUIRE ENGINEERING.
19. CONTRACTOR SHALL COORDINATE ANY BUILDING ACCESS REQUIREMENTS WITH THE OWNER.
20. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, TOOLS, EQUIPMENT, ETC. TO INSTALL/REPAIR
ALL MATERIALS FOR JOB.
21. IT SHALL NOT BE THE INTENT OF THESE PLANS AND SPECIFICATIONS TO SHOW EVERY MINOR DETAIL
OF CONSTRUCTION. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL MATERIALS
NECESSARY FOR A COMPLETE JOB AND PROVIDE ALL REQUIREMENTS FOR MATERIALS TO BE
INSTALLED IN PROPER WORKING CONDITIONS.
SHOP DRAWINGS
1. THE CONTRACTOR MUST SUBMIT SPECIFICATIONS FOR ALL THE MATERIAL BEING USED IN THIS
PROJECT FOR THE ENGINEER’S REVIEW.
2. NO SHOP DRAWING SHALL BE SUBMITTED FOR ENGINEER REVIEW UNTIL AFTER THEY HAVE BEEN
THOROUGHLY REVIEWED BY THE CONTRACTOR FOR CONSTRUCTION METHODS, DIMENSIONS AND
OTHER TRADE REQUIREMENTS AND STAMPED WITH THE CONTRACTORS’ APPROVAL STAMP.
ENGINEER ASSUMES NO RESPONSIBILITY FOR DIMENSIONS, QUANTITIES, ERRORS OR OMISSIONS
AS A RESULT OF REVIEWING ANY SHOP DRAWINGS. ANY ERRORS OR OMISSIONS MUST BE
RECTIFIED BY THE CONTRACTOR, IRRESPECTIVE OF RECEIPT, CHECKING OR REVIEW OF DRAWINGS
BY THE ENGINEER AND EVEN THOUGH WORK IS DONE IN ACCORDANCE WITH SUCH DRAWINGS.
3. THE STRUCTURAL ENGINEER REVIEWS SUBMITTAL TO CONFIRM THAT THE SUBMITTAL IS IN
GENERAL CONFORMANCE WITH THE DESIGN CONCEPT PRESENTED IN THE CONTRACT
DOCUMENTS. QUANTITIES AND DIMENSIONS ARE NOT CHECKED. NOTATIONS ON SUBMITTALS DO
NOT AUTHORIZE CHANGES TO THE CONTRACT SUM. CHECKING OF THE SUBMITTAL BY THE
STRUCTURAL ENGINEER SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR
DEVIATIONS FROM THE CONTRACT DOCUMENTS AND FROM ERRORS OR OMISSIONS IN THE
SUBMITTAL.
4. IF THE CONTRACTOR DEEMS THAT SHORING IS REQUIRED FOR CONSTRUCTION, SIGNED AND
SEALED SHOP DRAWINGS AND CALCULATIONS BY A FLORIDA PROFESSIONAL ENGINEER SHALL BE
SUBMITTED FOR REVIEW AND APPROVAL.
SAFETY
1. THE CONTRACTOR IS RESPONSIBLE AND SHALL COMPLY WITH THE SAFETY REQUIREMENTS
ESTABLISHED BY LOCAL, STATE AND FEDERAL LAWS.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY, ALL MEANS AND METHODS
PROCEDURES, AND SEQUENCES OF CONSTRUCTION. ALSO, IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO EMPLOY THE NECESSARY PROFESSIONAL SERVICES TO DETERMINE, DESIGN AND
SUPERVISE THE INSTALLATION OF THE APPROPRIATE MEANS AND METHODS FOR EXECUTION OF
THE REPAIR WORKS.
3. AT ALL TIMES, PROVIDE PROTECTION AGAINST WEATHER (RAIN, WIND, STORMS OR THE SUN), SO AS TO MAINTAIN ALL WORK, MATERIALS, APPARATUS AND FIXTURES FREE FROM INJURY OR DAMAGE.
4. PROVIDE AND MAINTAIN APPROPRIATE MEANS (E.G. BARRICADES) TO ISOLATE WORK AREAS OF
THE BUILDING DURING RESTORATION WORKS.
5. THE CONTRACTOR MUST PROVIDE DROP CLOTHS OR OTHER MEANS TO EFFECTIVELY PREVENT THE
FALLING OF DEBRIS.
6. THE CONTRACTOR MUST COORDINATE ALL WORKS WITH CITY OF DAYTONA BEACH.
7. FIRE PROTECTION SYSTEM SHALL REMAIN OPERATIONAL AT ALL TIMES DURING REPAIRS.
1. DESIGN IN ACCORDANCE WITH THE 2023 FLORIDA BUILDING CODE, EXISTING BUILDING, EIGHTH EDITION.
2. MINIMUM 28 DAY CONCRETE CYLINDER STRENGTH SHALL BE:
FOOTINGS 5000 PSI (MAXIMUM W/C=0.4), TYPE II CEMENT
COLUMNS 5000 PSI (MAXIMUM W/C=0.4), TYPE II CEMENT
BEAMS 5000 PSI (MAXIMUM W/C=0.4), TYPE II CEMENT
OTHERS 5000 PSI (MAXIMUM W/C=0.4), TYPE II CEMENT
3. REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60.
4. EPOXY COATED REINFORCING STEEL SHALL CONFORM TO ASTM A775 GRADE 60.
5. STRUCTURAL STEEL ANGLES AND OTHER ROLLED MEMBERS SHALL CONFORM TO ASTM A572 GRADE 50.
6. DESIGN LOADS:
DEAD LOADS SELF WEIGHT
5 PSF (MEP)
5 PSF (COLLATERAL)
LIVE LOAD 100 PSF (DECK)
50 PLF (UNIFORM, TOP RAIL)
200 LB (CONCENTRATED, TOP RAIL)
50 LB (CONCENTRATED, INTERMEDIATE
RAIL)
LIVE LOAD REDUCTION
LIVE LOAD REDUCTION PER FBC 2023 SECTION 1607.11 IS INCLUDED.
RAIN LOAD
RAIN INTENSITY 8.3 IN/HR.
WIND LOAD
RISK CATEGORY II
ULTIMATE WIND SPEED Vult = 140 MPH NOMINAL WIND SPEED Vasd = 109 MPH
EXPOSURE D
TORNADO DOES NOT CONTROL
INTERNAL PRESSURE COEFFICIENT GCpi = 0.0 (OPEN BUILDING)
COMPONENTS AND CLADDING REFER TO TABLE THIS SHEET
7. STRUCTURAL STEEL PLATES SHALL CONFORM TO THE FOLLOWING:
THICKNESS <= 1/8" ASTM A1011 CS TYPE B (OR APPROVED EQUAL)
3/16" <= THICKNESS <= 4" ASTM A572 GRADE 50
THICKNESS > 4" ASTM A36
8. THREADED RODS SHALL CONFORM TO ASTM A36 UNLESS NOTED OTHERWISE.
9. STRUCTURAL WOOD FRAMING SHALL CONFORM TO NFPA NATIONAL DESIGN SPECIFICATIONS (OR MEET
ALL THE MINIMUM PUBLISHED VALUES) AS FOLLOWS:
JOISTS SPECIES SYP GRADE SELECT STRUCTURAL
GUARDRAIL POSTS: SPECIES SYP GRADE No 1 OTHER SAWN LUMBER: SPECIES SYP GRADE No 2
10. RESISTANCE TO LATERAL LOADS ON STRUCTURE IS PROVIDED BY BOARDWALK DECK DIAPHRAGMS.
CONTRACTOR SHALL PROVIDE SUFFICIENT TEMPORARY BRACING UNTIL ALL LATERAL SUPPORT
SYSTEMS ARE IN PLACE AND FUNCTIONAL.
11. ALL STRUCTURAL FRAMING AND CONNECTIONS HAVE BEEN DESIGNED FOR THE FINAL COMPLETED CONDITION AND HAVE NOT BEEN INVESTIGATED FOR POTENTIAL LOADINGS ENCOUNTERED DURING
ERECTION AND CONSTRUCTION. ANY INVESTIGATION OF THE STRUCTURAL FRAMING AND
CONNECTIONS FOR ADEQUACY DURING THE ERECTION AND CONSTRUCTION PROCESS IS THE
RESPONSIBILITY OF THE CONTRACTOR.
12. CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION AND JOB SITE SAFETY.
SPALL REPAIRS AND CRACK SEALING
1. GENERAL
A. THE REPAIRS SHALL INCLUDE ALL AREAS WHERE SPALLS, CRACKS, DEBOND, AND
DELAMINATION ARE FOUND IN THE STRUCTURAL ELEMENTS, INCLUDING SLABS, COLUMNS,
GUARDRAILS, BEAMS AND WALLS.
B. CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, TOOLS AND EQUIPMENT, AND PERFORM ALL
PREPARATION, CONCRETE SPALL REPAIR, AND CONCRETE CRACK REPAIR, AS SHOWN ON THE
DRAWINGS, SPECIFIED HEREIN, AND REQUIRED FOR A COMPLETE AND PROPER INSTALLATION.
C. MATERIALS' MANUFACTURER MUST BE A COMPANY SPECIALIZED IN MANUFACTURING THE
PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM 20 YEARS DOCUMENTED EXPERIENCE.
D. ALL APPLICATIONS SHALL BE DONE BY A CERTIFIED INSTALLER (MINIMUM 10 YEARS OF
DOCUMENTED EXPERIENCE) FOLLOWING THE MANUFACTURERS’ DIRECTIONS AND STANDARDS.
THE CONTRACTOR MUST SUBMIT THE TECHNICAL SPECIFICATIONS FROM THE MANUFACTURER
FOR THE PRODUCTS SELECTED TO BE REVIEWED AND APPROVED BY THE ENGINEER.
E. PRIOR TO APPLICATION, REMOVE ALL DETERIORATED CONCRETE, DIRT, OIL, GREASE, AND ALL
BOND INHIBITING MATERIALS FROM SURFACE. PREPARATION WORK SHOULD BE DONE BY
APPROPRIATE MEANS IN ORDER TO OBTAIN THE CONDITIONS REQUIRED BY THE
MANUFACTURER FOR THE APPLICATION OF ANY SPECIFIC PRODUCT. SURFACE PREPARATION
METHODS MUST BE ACCORDING TO THE MANUFACTURERS' RECOMMENDATIONS AND
APPROVED BY THE ENGINEER AND OWNER BEFORE PROCEEDING.
F. BONDING AGENT, MIXING, APPLICATION AND CURING VARIES FROM PRODUCT TO PRODUCT. THE
CONTRACTOR MUST FOLLOW THE MANUFACTURERS’ RECOMMENDATIONS FOR EACH SPECIFIC
PRODUCT.
G. SURFACE PREPARATION WORKS MUST BE INSPECTED AND DEEMED ACCEPTABLE BY THE
OWNER AND ENGINEER, PRIOR TO APPLICATION OF THE SPECIFIED PRODUCTS.
H. CONTRACTOR SHALL PROTECT EXISTING REINFORCEMENT DURING REMOVAL OF DAMAGED
CONCRETE.
SPALL REPAIRS AND CRACK SEALING (CONT'D)
2. SPALL REPAIR MATERIALS
A. REPAIR ALL CONCRETE SPALLS, AREAS OF DELAMINATED CONCRETE, CONCRETE WITH
SURFACE EXPOSED REINFORCEMENT AND CONCRETE AREAS WHERE EMBEDDED STEEL SHOWS
SIGNS OF CORROSION.
B. FOR VERTICAL AND OVERHEAD SURFACES: MIX AND APPLY TWO-COMPONENT, POLYMER-
MODIFIED, CEMENTITIOUS, NON-SAG MORTAR, SIKATOP 123 PLUS AS MANUFACTURED BY SIKA
CORPORATION (OR APPROVED EQUAL BY ENGINEER) IN STRICT ACCORDANCE WITH THE
MANUFACTURER’S INSTRUCTIONS.
C. BONDING AGENT AND REINFORCEMENT PROTECTION COATING: BONDING AGENT AND ANTI-
CORROSION COATING SHALL BE SIKA ARMATEC 110 EPOCEM AS MANUFACTURED BY SIKA
CORPORATION (OR APPROVED EQUAL BY ENGINEER) IN STRICT ACCORDANCE WITH THE
MANUFACTURER’S INSTRUCTIONS.
3. CRACK REPAIR MATERIALS
A. CRACK SIZES VARY FROM HAIRLINE TO FINE. ALL CRACKS THAT NEED TO BE REPAIRED ARE NOT NECESSARILY SHOWN IN PLAN. ALL CRACKS WITH A WIDTH OF 0.01 INCHES AT ANY LOCATION OR
WIDER NEED TO BE SEALED AS INDICATED IN DETAILS.
B. HORIZONTAL GRAVITY-FED CRACK REPAIRS: MIX AND APPLY HYBRID URETHANE, 10-MINUTE
CONCRETE MENDER AS MANUFACTURED BY ROADWARE INCORPORATED (OR APPROVED EQUAL
BY ENGINEER) IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
C. VERTICAL AND OVERHEAD PRESSURE-INJECTED CRACK REPAIRS: MIX AND APPLY HIGH-
MODULUS, LOW-VISCOSITY, HIGH-STRENGTH, EPOXY RESIN ADHESIVE SIKADUR 35 HI-MOD LV AS
MANUFACTURED BY SIKA CORPORATION (OR APPROVED EQUAL BY ENGINEER) IN STRICT
ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS.
D. VERTICAL AND OVERHEAD CRACK SEALING AND INJECTION PORT INSTALLATION: MIX AND APPLY
HIGH-MODULUS, HIGH-STRENGTH, EPOXY PASTE ADHESIVE SIKADUR 31 HI-MOD GEL AS
MANUFACTURED BY SIKA CORPORATION (OR APPROVED EQUAL BY ENGINEER) IN STRICT
ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
SEAL:
DRAWN BY:
APPROVED BY:
SCALE:
CHECKED BY:
DATE:
PROJECT NUMBER:
PROJECT TITLE:
ISSUE:
PROJECT INFORMATION:
SHEET TITLE:
SHEET NUMBER:
AS NOTED
www.graef-usa.com
1 2 3 4 5 6
D
C
B
A
D
C
B
A
1 2 3 4 5 6
2300 Maitland Center Parkway, Suite 210 Maitland, FL 32751
407 / 659 6500
This item has been digitally signed and sealed by Scott D. Hinrichs, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Scott D. Hinrichs PE License #: 67810
CERT # 4270
PERMIT SET
C :\A ut od es k\
R ev it\ Lo ca l F ile s\
R el ea se
4\
-4
5_
S
_j ad
.a nt ou n.
rv t
5/
/2
5:
:4
P
M
CITY OF DAYTONA BEACH
MAIN STREET PIER
PARTIAL BOARDWALK AND
RAILING REPLACEMENT
GENERAL NOTES
05/23/2025
S001
2019-4115
JA
WL
SH
DESIGN SPECIFICATIONS
CONCRETE
GENERAL NOTES WOOD FRAMING
MISCELLANEOUS
WIND PROVISIONS FOR
COMPONENTS AND CLADDING
GENERAL NOTES (CONT'D)
A6A5A4A3A2A1
B6B5B4B3B2B1
C6C5C4C3C2C1
D6D5D4D3D2D1
LINE
BEYOND
CENTER, GRID
DEMOLITION
EXISTING
(HALFTONE)
HIDDEN
MATCHLINE
NEW (CUT)
NEW (PROJECTION)
OVERHEAD
MATERIAL
ALUMINUM
BRICK
CONCRETE
CONCRETE
MASONRY BLOCK
EARTH
GRAVEL
GROUT
WOOD STRUCTURAL
PANEL
STEEL
REFERENCE
BREAK LINE
N
A6
S-501
EXISTING GRID
INDICATOR
GRID INDICATOR
NORTH INDICATOR
SECTION VIEW
INDICATOR
SLOPE INDICATOR
STEP INDICATOR
REVISION CLOUD
SPAN DIRECTION
INDICATOR
ELEVATION VIEW
INDICATOR
KEYNOTE INDICATOR
REVISION INDICATOR
OPENING
(FLOOR, ROOF
OR WALL)
ELEVATION
INDICATOR
TOC
100'-0"
S-201
A1
A1
A1
A1B1
C1
D1
A6/S-501 VIEW INDICATOR
A6
S-501
VIEW CALLOUT
PC01
F01
DP01
TOPC 99'-0"
C01, P01
TOF 96'-0"
C01, P01
TODP 96'-0"
C01, P01
G B
TOF 96'-0"
FOUNDATION WALL,
CONTINUES UP
GRADE BEAM
PILE CAP
WALL FOOTING
FOOTING STEP
SPREAD FOOTING MARK
TOP OF FOUNDATION
ELEVATION
GRADE BEAM MARK
COLUMN OR PIER,
ENDS HERE
TOGB 99'-0"TOP OF GRADE
BEAM ELEVATION
CONCRETE COLUMN
OR PIER MARK
CJ
CJ
CJ
TOW 100'-0"TOP OF WALL
ELEVATION
SLAB ON GRADE CONTROL
OR CONSTRUCTION JOINT
CJ
PILE CAP MARK
COLUMN OR PIER,
CONTINUES UP
TOP OF PILE CAP
ELEVATION
SG01
TOC 100'-0"
FLOOR TYPE MARK
SPREAD FOOTING
TOP OF FOUNDATION
ELEVATION
DRILLED PIER
TOP OF DRILLED PIER
ELEVATION
DRILLED PIER MARK
F01
TOF 96'-0"
C01, P01
FOUNDATION WALL,
ENDS HERE
CJ
DOOR STOOP
F01
TOF 96'-0"
C01, P01
UTILITY THROUGH WALL
IE 95'-6"
TOF 95'-0"
CW01
WF01
WALL MARK
WALL FOOTING MARK
CONCRETE ENCASED
COLUMN
DIAGONAL BRACING ABOVE OR
BELOW
COLUMN CONTINUES
COLUMN ENDS HERE (BEAM
FRAMES OVER COLUMN)
ANGLE
KICKER
BRACE
BRACED BOTTOM FLANGE LOCATION
MOMENT CONNECTION
W x3
8)
1"
SECTION DESIGNATION
TOTAL NUMBER OF
SHEAR STUDS
CAMBER AT MIDSPAN
FACTORED AXIAL TRANSFER FORCE
(KIPS). DESIGN BEAM END CONNECTION
FOR TRANSFER FORCE IN ADDITION TO
SHEAR REACTION. FORCE MAY ACT IN
EITHER DIRECTION.
FACTORED END
SHEAR REACTION
(KIPS)
TOP OF STEEL ELEVATION, NOTED ON
EACH END INDICATES A SLOPED BEAM
CANTILEVER SAME SECTION AS
BACK SPAN UNLESS NOTED
OTHERWISE
CAMBER AT END OF CANTILEVER1"
COLUMN STARTS HERE
BEAM SPLICE
SHEAR CONNECTION
W P
BEAM WEB PENETRATION MARK
FACTORED END MOMENT
REACTION (FOOT-KIPS)
1'
-0
FL01
TOC 100'-0"
TOS 99'-6"
FLOOR TYPE MARK
EMBED PLATE
EDGE OF SLAB OR EDGE OF DECK
OPENING
BOTTOM FLANGE BRACE
JOIST BOTTOM
CHORD EXTENSION
FL01
TOC 100'-0"
B
SH01 SHEARHEAD MARK
DROP PANEL
BEAM MARK
BEAM
OPENING
FLOOR TYPE MARK
EDGE OF SLAB
COLUMN, CONTINUES
ABOVE FLOOR
COLUMN STRIP OR
MIDDLE STRIP
BOUNDARY
REINFORCEMENT, SHOWN
AND SCHEDULED ON PLAN
COLUMN, STOPS BELOW FLOOR
WALL, CONTINUES
ABOVE FLOOR
WALL, STOPS BELOW
FLOOR
SLAB UPWARD CAMBER
MARK
3/4"
CONCRETE SLAB ON
STEEL FLOOR DECK
(TRANSVERSE)
CONCRETE SLAB ON
STEEL FLOOR DECK
(LONGITUDINAL)
CONCRETE SLAB
ON GRADE
WELDED WIRE FABRIC
REINFORCEMENT
ANCHOR ROD
ADHESIVE ANCHOR
2'-0"
BENT BAR
2'-0" H x 3'-0" V
BAR DRILLED
AND EPOXY SET
INTO CONCRETE
EXPANSION ANCHOR
SHEAR STUDRAIL
REINFORCEMENT
SCREW ANCHOR
2# 4E
F
G
WALL REINFORCEMENT EXTENT
WALL TO BE GROUTED SOLID.
IF "G" IS OMITTED, GROUT WALL
CORES AT BAR LOCATIONS ONLY.
BAR SIZE
NUMBER OF BARS
BAR SPACING (INCHES)
LOCATION OF BAR(S) WITHIN
BLOCK CORE:
EF = 1/2 TOTAL NUMBER OF
BARS EACH FACE
C = CENTER IN WALL
IF = INSIDE FACE
OF = OUTSIDE FACE
VERTICAL BARS TO PASS
THROUGH INTERMEDIATE BOND
BEAMS
L0
MP01
MW01
MASONRY
WALL MARK
MASONRY
LINTEL MARK
MASONRY
PIER MARK
DEFINES OVER WHAT LENGTH OF
WALL REINFORCEMENT IS TO OCCUR
MASONRY
BEARING PLATE
MARK
MBP1 MBP1
STEEL BEAM
OR JOIST
BOND BEAM
CONCRETE MASONRY
UNIT (SECTION)
CONCRETE
MASONRY UNIT (TOP)
BRICK VENEER
L2 -1
H 2-
S
W
SW2
QUANTITY OF 2x MEMBERS
SAWN LUMBER HEADER
NOMINAL DEPTH
HOLD DOWN
SHEAR WALL
LVL HEADER OR BEAM
COLUMN
JOIST OR PRE-ENGINEERED
WOOD TRUSS
BEARING WALL
2 +/- 3.5 KIPS
HOLLOW CORE
PRECAST PLANK
(LONGITUDINAL)
HOLLOW CORE
PRECAST PLANK
(TRANSVERSE)
PRECAST TEE
(TRANSVERSE)
PRECAST TEE
(LONGITUDINAL)
STEEL ROOF DECK
(TRANSVERSE)
STEEL ROOF DECK
(LONGITUDINAL)
BOLT
SHEAR STUD
THREADED ROD
WOOD
BLOCKING OR
SHIM
WOOD FRAMING
WOOD GLULAM
WOOD MICROLAM
WOOD PARALAM
NAIL
LAG SCREW
SECTION TOP (T) FRONT (F) BACK (B) BOTTOM (BOT)
HP,
M, W
C, MC
L
(2) L
SLBB LLBB
HSS
HSS
(ROUND),
PIPE
MT,
WT
BG,
DLH,
G, K, LH,
VG
LLVLLH
T
BOT
F B
F B
T
BOT
T
BOT
T
BOT
T
BOT
T
BOT
T
BOT
T
BOT
SECTION ELEVATION (E)TOP (T)
T
T
T
T
T
T
E E
C JOIST
C STUD
FURRING
CHANNEL
FURRING
HAT
CHANNEL
LIGHT
GAUGE
ANGLE
RUNNER
CHANNEL
FL01
TOC 100'-0"
B
SH01 SHEARHEAD MARK
DROP PANEL
BEAM MARK
BEAM
OPENING
FLOOR TYPE MARK
EDGE OF SLAB
COLUMN, CONTINUES
ABOVE FLOOR
MILD REINFORCEMENT
COLUMN, STOPS AT FLOOR
F =X
X K
/F T
U
POST-TENSIONING FORCE
REQUIRED AT UNIFORM TENDONS
X
X X .X
X
UNIFORM POST-TENSIONING
TENDONS
X .X
X X
.X X
X.XXX.XXX.XX
F=XX K/FT
B
POST-TENSIONING FORCE
REQUIRED AT BANDED TENDONS
BANDED POST-TENSIONING TENDONS
X .X
X X
.X X
TENDON CGS ELEVATION AT MIDSPAN
OR CENTERLINE OF SUPPORT
FL01
TOC 100'-0"
G
01 GIRDER MARK
GIRDER
OPENING
FLOOR TYPE MARK
EDGE OF SLAB
COLUMN, CONTINUES
ABOVE FLOOR
COLUMN, STOPS AT FLOOR
F =X
X K
/F T
POST-TENSIONING FORCE
REQUIRED AT SLAB TENDONS
TENDON CGS ELEVATION AT MIDSPAN
OR CENTERLINE OF SUPPORT
G
B01
B01X .X
X X
.X X
X .X
X
B01
X .X
X
X .X
X
SLAB POST-TENSIONING TENDONS
BEAM MARK
BEAM
MILD REINFORCEMENTX
G
SEAL:
DRAWN BY:
APPROVED BY:
SCALE:
CHECKED BY:
DATE:
PROJECT NUMBER:
PROJECT TITLE:
ISSUE:
PROJECT INFORMATION:
SHEET TITLE:
SHEET NUMBER:
AS NOTED
www.graef-usa.com
1 2 3 4 5 6
D
C
B
A
D
C
B
A
1 2 3 4 5 6
2300 Maitland Center Parkway, Suite 210 Maitland, FL 32751
407 / 659 6500
This item has been digitally signed and sealed by Scott D. Hinrichs, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Scott D. Hinrichs PE License #: 67810
CERT # 4270
PERMIT SET
C :\A ut od es k\
R ev it\ Lo ca l F ile s\
R el ea se
4\
-4
5_
S
_j ad
.a nt ou n.
rv t
5/
/2
5:
:5
P
M
CITY OF DAYTONA BEACH
MAIN STREET PIER
PARTIAL BOARDWALK AND
RAILING REPLACEMENT
GENERAL INFORMATION
05/23/2025
S002
2019-4115
JA
WL
SH
1WAY ONE-WAY
AB ANCHOR BOLT
ADDL ADDITIONAL
ADDM ADDENDUM
AHU AIR HANDLING UNIT
ALT ALTERNATE
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
B PL BASE PLATE
B/B BACK TO BACK
BC BOTTOM CHORD
BF BOTH FACES
BF BOTTOM FACE
BLDG BUILDING
BM BEAM
BO __ BOTTOM OF __ (REFER TO TOP OF __)
BOT BOTTOM
BRDG BRIDGING
BRG BEARING
BRG PL BEARING PLATE
BS BOTH SIDES
BSMT BASEMENT
BW BOTH WAYS
C CHANNEL
C TO C CENTER TO CENTER
CANTIL CANTILEVER
CGS CENTER OF GRAVITY OF STRAND
CIP CAST-IN-PLACE
CJ CONSTRUCTION JOINT
CJ CONTROL JOINT
CL CENTER LINE
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECT
CONSTR CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CPRS COMPRESSIBLE
CTRL CONTROL
CU CUBIC
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
D DEEP
D DEPTH
DBE DECK BEARING ELEVATION
DBL DOUBLE
DEG DEGREE
DET DETAIL
DEMO DEMOLITION
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIR DIRECTION
DL DEAD LOAD
DWG DRAWING
E EAST
EA EACH
EE EACH END
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC
ELEV ELEVATOR
ENGR ENGINEER
EOD EDGE OF DECK
EOG EDGE OF GRATING
EOS EDGE OF SLAB
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
EW EACH WAY
EXC EXCAVATE
EXIST, (E) EXISTING
EXP EXPANSION
EXP BT EXPANSION BOLT
EXT EXTERIOR
FD FLOOR DRAIN
FDTN FOUNDATION
FF FAR FACE
FLR FLOOR
FR FRAME
FS FAR SIDE
FSTNR FASTENER
FT FEET
FTG FOOTING
FUT FUTURE
GA GAGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GLU LAM GLUE LAMINATED WOOD
GR BM GRADE BEAM
GRTG GRATING
H HIGH
HDG HOT-DIP GALVANIZED
HDR HEADER
HGR HANGER
HORIZ, H HORIZONTAL
HS HIGH STRENGTH
HSKPG HOUSEKEEPING
HT HEIGHT
I MOMENT OF INERTIA
ID INSIDE DIAMETER
IE INVERT ELEVATION
IF INSIDE FACE
INFO INFORMATION
INT INTERIOR
JST JOIST
JST BRG JOIST BEARING
K KIP (ONE THOUSAND POUNDS)
KB KNEE BRACE
KLF KIPS PER LINEAR FOOT
KOP KNOCK OUT PANEL
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
KWY KEYWAY
L ANGLE
LATL LATERAL
LB POUND
LD BRG LOAD-BEARING
LDH LONG DIMENSION HORIZONTAL
LDV LONG DIMENSION VERTICAL
LL LIVE LOAD
LLBB LONG LEG BACK TO BACK
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LVL LAMINATED VENEER LUMBER
LVR LOUVER
M MOMENT
MAX MAXIMUM
MBR MEMBER
MC MOMENT CONNECTION
MD METAL DECK
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
ML MONOLITHIC
MO MASONRY OPENING
MTL METAL
MULT MULTIPLE
N NORTH
NF NEAR FACE
NIC NOT IN CONTRACT
NLB NON LOAD-BEARING
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OPNG OPENING
OPH OPPOSITE HAND
OPP OPPOSITE
OPT OPTIONAL
O/O OUT TO OUT
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PL PLATE
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PRCST PRECAST
PRELIM PRELIMINARY
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POST-TENSIONED
PT PRESSURE TREATED
PT CONC POST-TENSIONED CONCRETE
QTY QUANTITY
R RADIUS
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCE
RENO RENOVATION
REQD REQUIRED
REV REVISION
RS ROUGH SAWN
RTU ROOF TOP UNIT
S SOUTH
SCHED SCHEDULE
SCHEM SCHEMATIC
SE STRUCTURAL ENGINEER
SECT SECTION
SF SQUARE FOOT (FEET)
SHT SHEET
SIM SIMILAR
SL SLAB
SLBB SHORT LEG BACK TO BACK
SP SUMP PIT
SPCL SPECIAL
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
STD STANDARD
STIF STIFFENER
STL JST STEEL JOIST
STRUC STRUCTURAL
SYMM SYMMETRICAL
SYP SOUTHERN YELLOW PINE
T&B TOP AND BOTTOM
TB THROUGH BOLT
TC TOP CHORD
TEMJ TOP ELEVATION MATCHES JOIST
TEMP TEMPORARY
THK THICKNESS
THRU THROUGH
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOCF TOP OF COLD-FORMED
TOD TOP OF DECK
TODP TOP OF DRILLED PIER
TOF TOP OF FOUNDATION
TOG TOP OF GRATING
TOGB TOP OF GRADE BEAM
TOP TOP OF PIER
TOPC TOP OF PILE CAP
TOS TOP OF STEEL
TOW TOP OF WALL
TS TUBE STEEL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VAR VARIES
VERT, V VERTICAL
VIF VERIFY IN FIELD
W WEST
W WIDE
W/ WITH
W/O WITHOUT
WBL WOOD BLOCKING
WD WOOD
WF WIDE FLANGE
WP WORK POINT
WT WEIGHT
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
YD YARD
LIST OF SHEETS
S001 GENERAL NOTES
S002 GENERAL INFORMATION
S100 OVERALL PLAN
S101 BOARDWALK PLAN
S200 DETAILS
S201 DETAILS
S202 DETAILS
S203 DETAILS
S204 SCHEDULES AND DETAILS
S205 EXIST CONC PILE CAP REPAIRS
ABBREVIATIONS
VIEW LOCATION LEGEND
FOUNDATION PLAN LEGEND
CONCRETE SHAPES LEGEND
SYMBOL LEGEND
STEEL PLAN LEGEND
ROOF DECK & ANCHORS SHAPES LEGEND
CONCRETE FLAT SLAB PLAN LEGEND
PT CONCRETE BEAM/SLAB PLAN LEGEND
PT CONCRETE FLAT SLAB PLAN LEGEND
WOOD SHAPES LEGEND
WOOD PLAN LEGEND
CONCRETE MASONRY PLAN LEGEND
CONCRETE MASONRY SHAPES LEGENDPRECAST CONCRETE SHAPES LEGEND
COLD-FORMED SHAPES LEGEND
STEEL SHAPES LEGEND
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
16.5
B E
N T
B E
N T
17.5
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B
E N
T
B E
N T
B E
N T
53A
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
SECTION 1
SECTION 2
SECTION 3
SECTION 4
SECTION 5
SECTION 6
SECTION 7
SECTION 8
S101
VIF
274'-5 3/4" +/-
S200
S200
S200
S200
S200
S200
S200
S200
S200
S200
S200
V
IF
34'-5" +/-
V
IF
75'-1 1/2" +/-
RENOVATION LIMIT
RENOVATION LIMIT
RENOVATION LIMIT
RENOVATION LIMIT
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
16.5
B E
N T
B E
N T
17.5
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B
E N
T
B E
N T
B E
N T
53A
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
SECTION 1
SECTION 2
SECTION 3
SECTION 4
SECTION 5
SECTION 6
SECTION 7
SECTION 8
S1013
S101
S200
S200
S200
S200
S200
S200
S200
S200
S200
S200
RENOVATION LIMIT
RENOVATION LIMIT
RENOVATION LIMIT
RENOVATION LIMIT
S200
S200
SIM
SIM
SIM
SIM
SIM
SIM
SIM
SIM
SIMSIM
SIM
1. DIMENSIONS OF EXIST STRUCTURE SHALL BE VERIFIED IN FIELD PRIOR TO ANY
CONSTRUCTION WORK. NOTIFY ENGINEER IMMEDIATELY IN CASE OF ANY DISCREPANCY
BETWEEN CONSTRUCTION DRAWINGS AND SITE CONDITIONS.
2. ALL NEWLY INSTALLED LUMBER SHALL BE PRESSURE TREATED. REFER TO GENERAL NOTES
ON SHEET S001 FOR SPECIFICATIONS.
3. CONTRACTOR SHALL VERIFY IN FIELD THE PRESENCE OF ANY EXIST UTILITY
CONDUITS/PIPING PRIOR TO ANY CONSTRUCTION WORK.
4. REFER TO ELECTRICAL, MECHANICAL & PLUMBING DRAWINGS FOR REPAIRS RELATED TO
BOARDWALK REPLACEMENT AND GUARDRAIL REPAIR WORK.
5. INDICATES AREA OF CONCRETE SLAB AND BEAMS TO BE DEMOLISHED.
6. INDICATES AREA OF GUARDRAIL WHERE PLYWOOD ABOVE THE DECK ELEVATION TO
BE REMOVED AND REPLACED WITH OPEN GUARD MEMBERS. SEE DEMO PLAN.
7. INDICATES AREA WHERE NEW OPEN GUARD IS TO BE INSTALLED AND FASTENED TO
WOOD POSTS. SEE RENO PLAN.
8. CONTRACTOR SHALL INCLUDE IN THE BIDDING PHASE COST OF EVERY REPAIR ITEM DEEMED
NECESSARY BUT NOT SHOWN ON THESE DRAWINGS IN ORDER TO COMPLETE THE SCOPE OF
WORK.
9. ALL NEW REINFORCING BARS ARE EPOXY COATED.
10. WOOD MEMBERS DEMOLISHED FROM EXISTING BOARDWALK SHALL NOT BE SALVAGED.
CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING ALL DEMOLISHED ELEMENTS AND
CONSTRUCTION DEBRIS TO A SOLID WASTE SITE DELEGATED BY THE LOCAL COUNTY SOLID
WASTE MANAGEMENT.
11. CONTRACTOR SHALL COORDINATE WITH OWNER THE EXPOSED CONC SURFACE FINISHES
INCLUDING, BUT NOT LIMITED TO, SMOOTH FINISH REQUIREMENT, AND PAINT AND COLOR
REQUIREMENTS.
12. TEMPORARILY SHORE THE EXIST STRUCTURE AS REQUIRED. SHORING DESIGN BY
CONTRACTOR.
13. TIGHTEN ALL EXISTING BOLTS THAT HAVE BECOME LOOSE.
14. INDICATES NEW DIAGONAL BRACING TO BE ADDED.
SEAL:
DRAWN BY:
APPROVED BY:
SCALE:
CHECKED BY:
DATE:
PROJECT NUMBER:
PROJECT TITLE:
ISSUE:
PROJECT INFORMATION:
SHEET TITLE:
SHEET NUMBER:
AS NOTED
www.graef-usa.com
1 2 3 4 5 6
D
C
B
A
D
C
B
A
1 2 3 4 5 6
2300 Maitland Center Parkway, Suite 210 Maitland, FL 32751
407 / 659 6500
This item has been digitally signed and sealed by Scott D. Hinrichs, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Scott D. Hinrichs PE License #: 67810
CERT # 4270
PERMIT SET
C :\A ut od es k\
R ev it\ Lo ca l F ile s\
R el ea se
4\
-4
5_
S
_j ad
.a nt ou n.
rv t
5/
/2
5:
:5
P
M
CITY OF DAYTONA BEACH
MAIN STREET PIER
PARTIAL BOARDWALK AND
RAILING REPLACEMENT
OVERALL PLAN
05/23/2025
S100
2019-4115
JA
WL
SH
3/64" = 1'-0"1
OVERALL DEMO PLAN
1 DEMO EXIST CONC SLAB, CONC BEAMS, CONC CORBEL ON SIDE OF FORMER SPACE NEEDLE
FOUNDATION, STEEL CHANNELS AND ANGLES WITHIN THE HATCHED AREA.
2 DEMO EXIST PLYWOOD OF THE GUARDRAIL ABOVE THE BOARDWALK ELEVATION ALONG THE
LENGTH INDICATED BY THE HATCH AND REPLACE WITH OPEN GUARD MEMBERS. DO NOT DEMO
OR CUT PLYWOOD THAT IS NOT DAMAGED BELOW THE BOARDWALK ELEVATION.
3 COORDINATE WITH MECHANICAL, PLUMBING, ELECTRICAL, AND FIRE PROTECTION FOR
RELOCATION OF EXIST FIXTURES.
4 EXIST CONC PILE CAP SHALL NOT BE DEMOLISHED. REFER TO SHEET S205 FOR CONCRETE
REPAIRS REQUIRED.
5 INSTALL NEW OPEN GUARD. SEE DETAILS FOR ADDITIONAL INFORMATION.
6 NEW DECK AND DECK SPANNING DIRECTION SHALL BE 2X8 MARINE GRADE BY
LUMBEROCK (OR APPROVED EQUAL). TOP OF DECK ELEVATION SHALL MATCH ADJACENT WOOD
DECK ELEVATION AND TOP OF EXIST CONC PILE CAP ELEVATION. SUBMIT COLOR OF DECK TO
OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION.
3/64" = 1'-0"2
OVERALL RENO PLAN
N
N GENERAL SHEET NOTES
SHEET KEYNOTES
(E) FORMER SPACE NEEDLE
FOUNDATION TO REMAIN
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
REFER TO OVERALL PLANS FOR
EXTENT OF DEMO OF EXIST
GUARDRAIL PLYWOOD
(E) TIMBER PILES, TYP
(E) TIMBER POSTS TO REMAIN.
VERIFY IN FIELD SPACING IS 8'-0"
OC MAX. NOTIFY ENGINEER IN
CASE OF DISCREPANCY.
VIF
15'-0 1/2"
VIF
34'-3 1/4"
(E) TIMBER JOISTS, TYP
(E) TIMBER BEAM, TYP
V
IF
'-0
V
IF
6' -1
/2
V
IF
'-0
/4
(E) WOOD DECK
ELEVATION
17'-2" +/- VIF
1 1
10 10
10 10
S200
S200 2
S200
S200 2
S200
S200
S200
S200
S200
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
CC1(16X16)
S203
V
IF
NEW
BEAM/COLUMN CL
(E) BOARDWALK EDGE (ABOVE)
(E) PILE CAP TO REMAIN
(E) TIMBER PILES, TYP
TOP OF EXIST FOUNDATION
ELEVATION SHALL BE
VERIFIED IN FIELD
AT BENT 1
- PILE 2
AT BENT 1
- PILE 3
AT BENT 1
- PILE 5
AT BENT 1
- PILE 6
AT BENT 2
- PILE 2
AT BENT 2
- PILE 5 AT BENT 3
- PILE 6
AT BENT 5
- PILE 3
AT BENT 5
- PILE 5
VIF
16'-2" +/-
VIF
16'-3 1/2" +/-
VIF
17'-7 3/4" +/-
VIF
14'-0 1/2" +/-
S200
NEW COMPOSITE DECK
(E) WOOD DECK
ELEVATION
17'-2" +/- VIF
(E) FORMER SPACE
NEEDLE FOUNDATION
C B
(1 x
V
IF
CC1(16X16)
(E) WOOD DECK
ELEVATION
17'-2" +/- VIF
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
B E
N T
(E) TIMBER PILES
(E) TIMBER POSTS TO REMAIN.
VERIFY IN FIELD SPACING OF EXIST MAIN POSTS ABOVE DECK IS 8'-0" OC
MAX, AND SPACING OF EXIST POSTS BELOW DECK (NOT SHOWN HERE
FOR CLARITY) IS 4'-0" OC MAX.
NEW INTERMEDIATE WOOD POSTS 6X6 WITH 2X6 DIAGONAL WOOD
BRACING SHALL BE ADDED TO ENSURE THE MAXIMUM DIMENSIONS
LISTED ABOVE ARE NOT EXCEEDED. THE NEW INTERMEDIATE WOOD
POSTS AND DIAGONAL BRACING SHALL BE FASTENED TO THE EXIST
DECK AND WOOD JOISTS PER DETAILS 2/201 AND 5/S201.
TYPICAL ALL EXIST POSTS.
S203
S203
NEW COMPOSITE DECK
V
IF
4' -7
/2
VIF
49'-1" +/-
7 7
TYP TYP
3' -0
S205
S201
S201
TYP
S203
S203
S203
S203
S201
S201
S201
S200
S200 1
S200
S200 1
S200
S200
S200
S200
S200
2'-4" +/- 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 6'-9" +/-
TYP
TYP
NEW 6X6 TIMBER POST
ADJACENT TO EXIST
POST, VIF. SEE DETAIL
6/S201 FOR CONNECTIONS
(E
4X
B E
A M
U
N D
E R
J O
IS
T
V
IF
(E
X
B
E A
M
T
N T
, V
IF
S202
S202
(E
4X
B E
M
U
N D
E R
J O
IS
T
V
IF
S202
(E
X
B
E A
M
T
N T
, V
IF
S202
13 TYP
S202
'-0
1'
-6
'-0
1'
-6
1' -6
'-1 0"
1' -6
'-1 0"
1' -6
VIF
13'-9 3/8" +/-
VIF
14'-9" +/-
VIF
16'-0 1/4" +/-
VIF
14'-10 3/4" +/-
S202
S202
TYP
S202
SIM
SIM
SIM
SIM
SIM SIM
SIM
SIM
SIM
REPAIR POST ANCHOR BOLT
VIF, TYP
8'-0" OC MAX
1. DIMENSIONS OF EXIST STRUCTURE SHALL BE VERIFIED IN FIELD PRIOR TO ANY
CONSTRUCTION WORK. NOTIFY ENGINEER IMMEDIATELY IN CASE OF ANY DISCREPANCY
BETWEEN CONSTRUCTION DRAWINGS AND SITE CONDITIONS.
2. ALL NEWLY INSTALLED LUMBER SHALL BE PRESSURE TREATED. REFER TO GENERAL NOTES
ON SHEET S001 FOR SPECIFICATIONS.
3. CONTRACTOR SHALL VERIFY IN FIELD THE PRESENCE OF ANY EXIST UTILITY
CONDUITS/PIPING PRIOR TO ANY CONSTRUCTION WORK.
4. REFER TO ELECTRICAL, MECHANICAL & PLUMBING DRAWINGS FOR REPAIRS RELATED TO
BOARDWALK REPLACEMENT AND GUARDRAIL REPAIR WORK.
5. INDICATES AREA OF CONCRETE SLAB AND BEAMS TO BE DEMOLISHED.
6. INDICATES AREA OF GUARDRAIL WHERE PLYWOOD ABOVE THE DECK ELEVATION TO
BE REMOVED AND REPLACED WITH OPEN GUARD MEMBERS. SEE DEMO PLAN.
7. INDICATES AREA WHERE NEW OPEN GUARD IS TO BE INSTALLED AND FASTENED TO
WOOD POSTS. SEE RENO PLAN.
8. CONTRACTOR SHALL INCLUDE IN THE BIDDING PHASE COST OF EVERY REPAIR ITEM DEEMED
NECESSARY BUT NOT SHOWN ON THESE DRAWINGS IN ORDER TO COMPLETE THE SCOPE OF
WORK.
9. ALL NEW REINFORCING BARS ARE EPOXY COATED.
10. WOOD MEMBERS DEMOLISHED FROM EXISTING BOARDWALK SHALL NOT BE SALVAGED.
CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING ALL DEMOLISHED ELEMENTS AND
CONSTRUCTION DEBRIS TO A SOLID WASTE SITE DELEGATED BY THE LOCAL COUNTY SOLID
WASTE MANAGEMENT.
11. CONTRACTOR SHALL COORDINATE WITH OWNER THE EXPOSED CONC SURFACE FINISHES
INCLUDING, BUT NOT LIMITED TO, SMOOTH FINISH REQUIREMENT, AND PAINT AND COLOR
REQUIREMENTS.
12. TEMPORARILY SHORE THE EXIST STRUCTURE AS REQUIRED. SHORING DESIGN BY
CONTRACTOR.
13. TIGHTEN ALL EXISTING BOLTS THAT HAVE BECOME LOOSE.
14. INDICATES NEW DIAGONAL BRACING TO BE ADDED.
SEAL:
DRAWN BY:
APPROVED BY:
SCALE:
CHECKED BY:
DATE:
PROJECT NUMBER:
PROJECT TITLE:
ISSUE:
PROJECT INFORMATION:
SHEET TITLE:
SHEET NUMBER:
AS NOTED
www.graef-usa.com
1 2 3 4 5 6
D
C
B
A
D
C
B
A
1 2 3 4 5 6
2300 Maitland Center Parkway, Suite 210 Maitland, FL 32751
407 / 659 6500
This item has been digitally signed and sealed by Scott D. Hinrichs, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Scott D. Hinrichs PE License #: 67810
CERT # 4270
PERMIT SET
C :\A ut od es k\
R ev it\ Lo ca l F ile s\
R el ea se
4\
-4
5_
S
_j ad
.a nt ou n.
rv t
5/
/2
5:
:0
P
M
CITY OF DAYTONA BEACH
MAIN STREET PIER
PARTIAL BOARDWALK AND
RAILING REPLACEMENT
BOARDWALK PLAN
05/23/2025
S101
2019-4115
JA
WL
SH
1/8" = 1'-0"1
BOARDWALK PLAN - DEMO
N
1/8" = 1'-0"3
BOARDWALK PLAN -RENO
1/8" = 1'-0"2
FOUNDATION PLAN - RENO
1 DEMO EXIST CONC SLAB, CONC BEAMS, CONC CORBEL ON SIDE OF FORMER SPACE NEEDLE
FOUNDATION, STEEL CHANNELS AND ANGLES WITHIN THE HATCHED AREA.
2 DEMO EXIST PLYWOOD OF THE GUARDRAIL ABOVE THE BOARDWALK ELEVATION ALONG THE
LENGTH INDICATED BY THE HATCH AND REPLACE WITH OPEN GUARD MEMBERS. DO NOT DEMO OR
CUT PLYWOOD THAT IS NOT DAMAGED BELOW THE BOARDWALK ELEVATION.
3 COORDINATE WITH MECHANICAL, PLUMBING, ELECTRICAL, AND FIRE PROTECTION FOR RELOCATION
OF EXIST FIXTURES.
4 EXIST CONC PILE CAP SHALL NOT BE DEMOLISHED. REFER TO SHEET S205 FOR CONCRETE REPAIRS
REQUIRED.
6 NEW DECK AND DECK SPANNING DIRECTION SHALL BE 2X8 MARINE GRADE BY LUMBEROCK
(OR APPROVED EQUAL). TOP OF DECK ELEVATION SHALL MATCH ADJACENT WOOD DECK ELEVATION AND TOP OF EXIST CONC PILE CAP ELEVATION. SUBMIT COLOR OF DECK TO OWNER FOR REVIEW
AND APPROVAL PRIOR TO INSTALLATION.
7 NEW WOOD JOIST, 4X12 SPACED AT 16" ON CENTER MAX. PROVIDE 4X12 BLOCKING AT
SUPPORTS FASTENED TO JOISTS WITH (1) SS A34 CLIP ANGLE, TYP ALL JOISTS.
8 RE-INSTALL EXIST LIGHT POLE. COORDINATE LIGHT POLE LOCATION AND OTHER FIXTURES WITH
ELECTRICAL EOR.
9 REPAIR EXIST ROTTED 12" +/- DIA (VIF) WOOD PILE WITH JACKETING PER DETAIL 5/S203.
10 ALL EXPOSED SECTIONS OF EXIST REINF STEEL SHALL BE REPAIRED WITH CORROSION
PROTECTION AFTER THE EXIST CONC BEAM IS SAW-CUT AND REMOVED. GRIND THE REMAINDER OF
THE EXIST REBAR DOWN TO 1" BELOW CONC SURFACE, ABRASIVELY CLEAN AND PATCH WITH
EPOXY GROUT TO SEAL FROM FUTURE CORROSION.
11 NEW WOOD POST 6X6 STARTING FROM BOTTOM OF SIDING AND EXTENDS TO TOP OF
HORIZONTAL RAIL.
12 NEW INTERMEDIATE WOOD POST 6X6 STARTING FROM BOTTOM OF SIDING AND EXTENDS TO
BOTTOM OF DECK.
13 NEW HORIZONTAL X-CROSS BRACING WITH TYPE 316 SS WIRE ROPE, 5/16" DIA-7X19. PROVIDE 316 SS
TURNBUCKLES, CLIPS AND THIMBLES AS NEEDED FOR POST-TENSIONING WIRE ROPE BRACING.
POST-TENSIONING FORCE TO BE 400 LBS MINIMUM, AND 800 LBS MAXIMUM.
14 NEW BEAM 4X12 UNDER EXIST JOISTS WITH (2) 4X10 DIAGONAL BRACES. BEAM TO ALIGN WITH WOOD
POST AT RAIL/SIDING.
15 NEW DIAGONAL BRACE SIMILAR TO DETAIL 6/S202.
16 ADD SIMPSON SS STRAP TO REPAIR EXIST POST WITH CORRODED ANCHOR BOLT. SEE DETAIL 6/S201.
N
N
GENERAL SHEET NOTES
SHEET KEYNOTES
EQ (**) EQ (**) EQ (**) EQ (**)
3' -6
1/ 2"
4' -0
S201
S201
S201
S201
MIN 3/4" APA-RATED
MARINE-GRADE
PLYWOOD
2X6 2X122X4
6X6 TIMBER
POST, TYP
6X6 INTERMEDIATE
TIMBER POST
4X12 WOOD
JOIST (BEYOND)
S200
S200
NOTES:
1. NEW APA-RATED MARINE-GRADE PLYWOOD SHALL HAVE A MINIMUM THICKNESS OF 3/4". CONTRACTOR SHALL MATCH EXISTING PLYWOOD THICKNESS IF FOUND THICKER THAN 3/4".
2. *: BOTTOM ELEVATION OF NEW SIDING SHALL MATCH BOTTOM ELEVATION OF EXIST SIDING TO REMAIN. NOTIFY ENGINEER IN CASE OF DISCREPANCY.
3. **: SPACING SHALL NOT EXCEED 4'-0" OC AT THE EXIST SECTION OF THE GUARDRAIL TO BE REPAIRED. IF SPACING EXCEEDS 4'-0" OC (VIF), PROVIDE NEW INTERMEDIATE TIMBER POST
6X6 FROM BOTTOM OF SIDING TO UNDERSIDE OF DECK. FASTEN POST TO DECK JOISTS PER DETAIL 2/201, TYP
NEW COMPOSITE
DECK
1/
2"
SEE PLAN SEE PLAN
2X6
NEW 4X12 WOOD
JOIST. SEE PLANS
FOR SPACING
NEW 2X8 COMPOSITE MARINE GRADE DECKING BY
LUMBEROCK (OR APPROVED EQUAL). PROVIDE
1/4" WIDE JOINT BETWEEN DECK PLANKS OR PER
DECK MANUFACTURER SPECIFICATIONS
(2)#10X3" LONG SS FLAT HEAD DECK
SCREWS AT EACH PLANK CONNECTION.
MINIMUM EDGE DISTANCE 1"
PERPENDICULAR TO WOOD GRAIN,
1-1/2" PARALLEL TO WOOD GRAIN, TYP.
NOTE:
1. DECK PLACEMENT PER MANUFACTURER'S SPECIFICATIONS.
2X6
3' -6
1/ 2"
D E
C K
4' -0
2X8 COMPOSITE MARINE
GRADE DECKING BY
LUMBEROCK (OR
APPROVED EQUAL)
NEW 2X6 BRACING TIE
ALIGNED TO POST WITH (3)
SIMPSON SS 1/4"x3-1/2"
SCREWS AT EACH JOIST
2X6 DIAGONAL BRACING
AT EACH POST
6X6 TIMBER POST (SEE
PLAN FOR SPACING)
4X12 WOOD JOISTS (SEE
PLAN FOR SPACING)
2X6 SPACED AT 24" OC MAX.
INTERMEDIATE HORIZ STUDS WITH
(2) SIMPSON SDWS27300SS SCREWS
AT EACH POST, MINIMUM EDGE
DISTANCE 1" PERPENDICULAR TO
GRAIN AND 1-1/2" PARALLEL TO
GRAIN (TYP)
7' -7
/2
S200
S200
2X6
2X6
2X6 HORIZONTAL RAIL WITH (3) SDWS27300SS FLAT HEAD SCREW AT
EACH POST WITH 1" (MIN) EDGE DISTANCE (TYP)
1/
2"
MIN 3/4" THICK APA-RATED
MARINE-GRADE PLYWOOD
2X6
2X6 TOP & BOTTOM HORIZONTAL
STUDS WITH (2) SIMPSON
SDWS27300 SS SCREWS AT EACH
POST, MINIMUM EDGE DISTANCE 1"
PERPENDICULAR TO GRAIN AND
1-1/2" PARALLEL TO GRAIN (TYP)
T.O. DECK
TO MATCH ADJACENT (VIF)
S201
2X4, EACH FACE WITH (2) SDWS27300SS FLAT HEAD SCREW AT
EACH POST WITH 1" (MIN) EDGE DISTANCE (TYP)
2X12 (PLACE WOOD CROWN UP, TYP). PLACE WOOD GRAIN CUT
FACING DOWN WITH SDWS27300SS FLAT HEAD SCREW AT 18" ON
CENTER ON RAIL EACH SIDE WITH 1" (MIN) EDGE DISTANCE
1+/-
CLIP ANGLE SIMPSON
ML28SS WITH (5) SIMPSON SS
1/4"x1-1/2" SDS SCREW
DIAGONAL BRACING AND
BRACING TIE
E Q
U A
L E
Q U
A L
E Q
U A
L
T Y
P
1/
2"
MIN
1'-6"
/8
(1) 5/8" ⌀ SS THRU BOLTS WITH 2-1/2"
DIA SS FENDER WASHER, MINIMUM
EDGE DISTANCE 3" PARALLEL TO GRAIN
3/4" 2"
2' -3
1/ 4"
SIMPSON 10d SS NAIL @
12" ON CENTER AT
INTERMEDIATE HORIZ
SUPPORTS
10d SS NAIL @ 6" ON
CENTER AT PERIMETER
SUPPORTS
WALL PERIMETER EDGE PLYWOOD PANEL (TYP) PANEL JOINT (TYP)
T Y
P
'-0
(W
ID
E
WOOD INTERMEDIATE
SUPPORT 2X, TYP
WOOD PERIMETER
SUPPORT 2X, TYP
VIF
8'-0"
VIF
8'-0"
V
IF
3' -6
V
IF
1/ 2"
V
IF
4' -0
(E) 3/4" THICK PLYWOOD
TO REMAIN, VIF
(E) TOP RAIL TO
BE REMOVED
NOTES:
1. DENOTES EXIST PLYWOOD SIDING, TOP RAILS, VERTICAL STUDS, AND HORIZONTAL STUDS TO BE DEMOLISHED EXCEPT EXIST WOOD POSTS AND DIAGONAL BRACING TO REMAIN.
2. DENOTES AREA TO REMAIN. DO NOT REMOVE ANY EXIST WOOD MEMBERS LOCATED IN THIS AREA.
3. EXIST PLYWOOD TO BE REMOVED WITHIN AREA OF DEMOLITION. ALL PLYWOOD LOCATED UNDER THE EXIST WOOD DECK SHALL BE REMOVED TEMPORARILY, MODIFIED, CLEANED, REPAINTED, AND RE-INSTALLED PER THE REVISED ELEVATION IF THERE IS NO DAMAGE OR DEFECT.
4. EXIST HORIZ WOOD STUDS LOCATED WITHIN THE AREA OF PLYWOOD TO REMAIN SHALL NOT BE REMOVED.
5. REFER TO DETAIL 1 THIS SHEET FOR INSTALLATION OF OPEN GUARD ABOVE AND BELOW THE EXIST WOOD DECK.
(E) WOOD DECK
TO REMAIN
AREA OF
DEMOLITION,
SEE NOTE 1
(E) VERTICAL WOOD STUDS
SUPPORTING UPPER SECTION OF
INSIDE FACE PLYWOOD SIDING TO
BE DEMOLISHED, TYP
(E) HORIZ WOOD RAILS
SUPPORTING UPPER SECTION OF
OUTSIDE FACE PLYWOOD SIDING
TO BE DEMOLISHED, TYP
(E) HORIZ WOOD RAILS SUPPORTING
LOWER SECTION OF OUTSIDE FACE
PLYWOOD TO REMAIN, TYP
(E) 6X6 VERTICAL WOOD POSTS
SUPPORTING BOTH UPPER AND
LOWER SECTION OF PLYWOOD
SIDING TO REMAIN, TYP, VIF
V
IF
8' -0
SEAL:
DRAWN BY:
APPROVED BY:
SCALE:
CHECKED BY:
DATE:
PROJECT NUMBER:
PROJECT TITLE:
ISSUE:
PROJECT INFORMATION:
SHEET TITLE:
SHEET NUMBER:
AS NOTED
www.graef-usa.com
1 2 3 4 5 6
D
C
B
A
D
C
B
A
1 2 3 4 5 6
2300 Maitland Center Parkway, Suite 210 Maitland, FL 32751 407 / 659 6500
This item has been digitally signed and sealed by Scott D. Hinrichs, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Scott D. Hinrichs PE License #: 67810
CERT # 4270
PERMIT SET
C :\A ut od es k\
R ev it\ Lo ca l F ile s\
R el ea se
4\
-4
5_
S
_j ad
.a nt ou n.
rv t
5/
/2
5:
:0
P
M
CITY OF DAYTONA BEACH
MAIN STREET PIER
PARTIAL BOARDWALK AND
RAILING REPLACEMENT
DETAILS
05/23/2025
S200
2019-4115
JA
WL
SH
1" = 1'-0"1
NEW GUARD EXTERIOR ELEVATION
1" = 1'-0"4
NEW DECK DETAIL
1" = 1'-0"3
DETAIL - NEW GUARDRAIL SECTION AT INTERMEDIATE POST
NTS5
PLYWOOD WALL PANEL FASTENER SCHEDULE
1" = 1'-0"2
EXIST GUARD SIDING DEMO ELEVATION
2X6 HORIZONTAL RAIL WITH (3) 1/4"x3-1/2" SDS SS SCREWS
AT EACH POST, 1" (MIN) EDGE DISTANCE…