Attachment_7_-_Sample_Scenario.pdf

PDF 30 KB Posted

Attached to
Environmental Services in California
Solicitation number
SP0600-13-R-0515
Issued by

About this file

Attachment 7 - Sample Scenario

View the file

Other files

File Type Posted
Amendment_0006.pdf PDF
Amendment_0005.pdf PDF
Amendment_0004.pdf PDF
Attachment_3_-_Price_Proposal_Worksheets.xlsx XLSX spreadsheet
Amendment_0003.pdf PDF
Amendment_0002.pdf PDF
Performance_Work_Statement_05_16_13.pdf PDF
Attachment_2_-_Fill-in_Clauses.pdf PDF
Attachment_3_-_Price_Proposal_Worksheets.xlsx XLSX spreadsheet
Amendment_0001.pdf PDF
Attachment_3_-_Price_Proposal_Worksheets.xlsx XLSX spreadsheet
Attachment_4_-_Wage_Determination_-_DFSP_Norwalk_and_San_Pedro _CA_Wage_Determination.pdf PDF
Attachment_5_-_DLA_Energy_19.3.pdf PDF
Attachment_2_-_Fill-in_Clauses.pdf PDF
Attachment_3_-_Price_Proposal_Worksheets.xlsx XLSX spreadsheet
ATTACHMENT_1_-_Performance_Work_Statement.pdf PDF
Attachment_6_-_Past_Performance_Questionnaire.xlsx XLSX spreadsheet
Attachment_4_-_Wage_Determination_-_DFSP_Ozol _CA.pdf PDF
SP0600-13-R-0525_-_FINAL.pdf PDF
Attachment_3_-_Price_Proposal_Worksheets.xlsx XLSX spreadsheet
Attachment_2_-_Fill-in_Clauses.pdf PDF
Attachment_7_-_Sample_Scenario.pdf PDF
Attachment_5_-_DLA_Energy_19.3.pdf PDF
DFSP_Norwalk_and_San_Pedro _CA_Wage_Determination.pdf PDF
Solicitation_04_08_13_Draft_Copy.pdf PDF
Attachment_6_-_Past_Performance_Questionnaire.xlsx XLSX spreadsheet
DFSP_Ozol _CA_Wage_Determination.pdf PDF
DRAFT_-_Performance_Work_Statement.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SP0600-13-R-0515

ATTACHMENT 7

SCENARIO:

(1) BACKGROUND: The site is a facility for the receipt, storage, and distribution of JP-8 although previously JP-4 and AVGAS were stored. Twelve field constructed underground tanks each with a capacity of approximately 3,500,000 gallons are used for storage. Fuel is transferred to, from, and within the facility via an underground pipeline network. A routine check of an existing monitoring well adjacent to one of the storage tanks indicates the presence of free phase hydrocarbon.

(2) SITE GEOLOGY: The regional geology in the area is characterized as claystone, siltstone and minor sandstone. Based on the monitoring well drilling logs, the sites subsurface lithology consists of colluviums up to 30 feet thick.

The colluvium grades into a highly weathered bedrock zone.

(3) HYDROGEOLOGY: Based on the groundwater measurements in the existing monitoring wells, two water-bearing zones are present: an upper shallow water-bearing zone, and a lower regional groundwater system. The upper water-bearing zone is contained within the weathered bedrock and fill around the tanks, and flows away from the tanks in a radial pattern generally following surface topography. Depth to shallow aquifer is 25 feet. A lower water-bearing zone, which is hypothesized as being recharged from the upper zone through joints and fractures, has been identified at a depth of 90’. Groundwater flow within the lower water system is generally to the north toward a tidal estuary that borders the site.

END OF SCENARIO