S02 - Volume 2 Drawings.pdf

PDF 8 MB Posted

Attached to
Z1DA--607-21-155 UPGRADE EAGLE AND FREIGHT ELEVATORS (VA-23-00006591)
Solicitation number
36C25222B0034
Issued by

About this file

This document outlines the requirements for an elevator modernization project at the William S. Middleton Memorial VA Medical Center in Madison, Wisconsin. The project involves upgrading four passenger elevators and one freight elevator to meet current code and improve reliability and efficiency.

The solicitation was issued by the Department of Veterans Affairs for project number 607-21-155. Responses are due by May 27th, 2022. The awarded contractor will be responsible for removing existing equipment and installing new machines, controls, cab interiors, and other components. The work must be phased to minimize disruptions to hospital operations.

The project also includes mechanical, electrical, fire protection, and fire alarm upgrades in the elevator machine room on the ninth floor. Existing air handling units, ductwork, piping, and controls will be removed and replaced. A new enclosed machine room space will be constructed.

Drawings and specifications are provided giving requirements for demolition, new construction, and coordination between trades. The contractor must obtain all necessary approvals and permits and complete work in accordance with applicable codes and VA specifications.

View the file

Other files

File Type Posted
S06 - Spec Section 251300 - Integration.pdf PDF
S06 - SF 1442.pdf PDF
36C25222B0034 0003.docx DOCX document
P07 - Wage Determination Revised.pdf PDF
36C25222B0034 0002.docx DOCX document
S04 - Pre-Bid Sign in Sheet.pdf PDF
36C25222B0034 0001.docx DOCX document
S02 - Volume 2 Specifications.pdf PDF
S02 - Volume 1 Specifications.pdf PDF
P07 - Wage Determination.pdf PDF
36C25222B0034_1.docx DOCX document
S02 - Volume 1 Drawings.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

K-2031GREENWICHLAVATORYVITREOUS CHINA

K-2031GREENWICHLAVATORYVITREOUS CHINA

VITREOUS CHINAC_TOILETSKINGSTONK-4330

K-2031GREENWICHLAVATORYVITREOUS CHINA

VITREOUS CHINAC_TOILETSKINGSTONK-4330

K-2031GREENWICHLAVATORYVITREOUS CHINA K-2031GREENWICHLAVATORYVITREOUS CHINA

VITREOUS CHINAC_TOILETSKINGSTONK-4330 VITREOUS CHINAC_TOILETSKINGSTONK-4330

2-1/2" HW

3" CW

1/

2"

1/2"

4" STAND PIPE

2"

3"

2"

4" 1 1/2"

1/2"

1 1/2"

DWR

4"

2" 4"

4"2"

1 1/2"

2"

4"

2" 1 1/2"

4"

1 1/2"

4"

2"

SINK

2-1/2"HW,

3/4"DW

2"CW, 1-1/4"HW UP,

2-1/2"CW, 1-1/2"HW DN,

1-1/2"DW DN

DHW-134

2" SAN DN.

2" V UP

2" SAN UP/DN.

2" V UP/DN.

2" CW UP/DN.

4" HW UP/DN.

4" SAN UP/DN.

2" V UP/DN.

2" CW UP/DN.

4" HW UP/DN.

4" SAN UP/DN.

3" V UP/DN.

4" SAN UP/DN.

2" V UP/DN.

2" SAN DROP

2"

2" 4"

1 1/2" 2"

2"

4"

1 1/2"

4" CW 3

4" HW

5" S UP/DN

4" HW

4" CW

2" CW DN.

1" HW DN.

2-1/2" CW

1-1/4" HW21

2" CW 32 CWFU

4" HW 12 HWFU

1" C

W 1"

H W

FD

-W

FD

-W

FD

-W

FD

-W

FD

-W

FD

-W

1-1/2" V UP

3/4" CW UP/DN

2" V

FD

1-1/4" HW

FD

FD FD

1-1/4" HW

2-1/2" CW

2" HW

3" CW

1" HW

1" CW

1-1/4" HW

2-1/2" CW

1-1/4" HW, CW

3/4" HW, CW

4"

1 1/2" 1 1/2"

1 1/2"

3/4" HW, CW

1-1/2"CW,

1-1/4"HW UP

1-1/2"CW,

1-1/4"HW DN

1 1/2"

1 1/2" 2"

4"

4" 1"HW UP,

1-1/4"HW DN

2" SAN UP TO FD FD-W

2" V DN.

4" CW DN.

3/4" CW DN. TO CW-13

CONNECT TO HVAC

BACKFLOW PREVENTER

2" VTR

SEE 1/4" PLAN DETAIL THIS

SHEET FOR WORK THIS AREA

NEW 1-1/2" HWS & HWR UP

1/

2"

2"

3"

2"

4" 1 1/2"

SINK

2-1/2"HW,

3/4"DW

2-1/2" CW

1-1/4" HW

1-1/4" HW

2-1/2" CW

3/4" HW, CW

1-1/2"CW,

1-1/4"HW DN

12" 0 1' 5' 10' 20'

SCALE: 1/8" = 1'-0"

THIRD FLOOR PLAN - C-WING - PLUMBING DEMOLITION1

Elevator:

PO Box 464

Phone: 608.616.2999 Mequon, WI 53092

UPGRADE EAGLE AND FREIGHT

ELEVATORS

Email: AdamS@pec-wi.com POC: Aslam Husain

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

35% Schematic Design 10.15.2021 5.27.22

Project Number

Building Number

607-21-155

B A

C G

POC: Adam Smith

B-Core

65% Construction Documents 12.29.2021 95% Construction Documents 3.18.2022 100% Construction Documents 5.27.2022

DEMO PLAN NOTES

GENERAL DEMOLITION NOTES:

12" 0 1' 5' 10'

SCALE: 1/4" = 1'-0"

THIRD FLOOR - C-WING - ENLARGED PLAN - PIPING PLAN2

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text C3129A

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text C3116A

AutoCAD SHX Text

EX. FEC

AutoCAD SHX Text C3134A

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

ELEC. CLO.

AutoCAD SHX Text C3133

AutoCAD SHX Text

EXAM 4

AutoCAD SHX Text C3112

AutoCAD SHX Text

PUBLIC CORRIDOR

AutoCAD SHX Text C3150B

AutoCAD SHX Text

CHANGING

AutoCAD SHX Text C3123A

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text C3150E

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text C3150C

AutoCAD SHX Text

P-TUBE

AutoCAD SHX Text

STATION

AutoCAD SHX Text C3125A

AutoCAD SHX Text

STERILE

AutoCAD SHX Text

INSTRUMENT

AutoCAD SHX Text C3116

AutoCAD SHX Text

EXAM 7

AutoCAD SHX Text C3128

AutoCAD SHX Text

EXAM 6

AutoCAD SHX Text C3126

AutoCAD SHX Text

EXAM 5

AutoCAD SHX Text C3118

AutoCAD SHX Text

SOIL. UTIL.

AutoCAD SHX Text C3117

AutoCAD SHX Text

PROCEDURE

AutoCAD SHX Text C3124

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text C3134

AutoCAD SHX Text

WAITING

AutoCAD SHX Text C3109A

AutoCAD SHX Text

PATIENT CORRIDOR

AutoCAD SHX Text C3150D

AutoCAD SHX Text

TOILET

AutoCAD SHX Text C3121

AutoCAD SHX Text

GOWNING

AutoCAD SHX Text C3123

AutoCAD SHX Text

PROCEDURE

AutoCAD SHX Text C3127

AutoCAD SHX Text

RECEPTION

AutoCAD SHX Text C3109

AutoCAD SHX Text

EXAM 9

AutoCAD SHX Text C3130

AutoCAD SHX Text

TOILET

AutoCAD SHX Text C3122

AutoCAD SHX Text

TOILET

AutoCAD SHX Text C3119

AutoCAD SHX Text

EXAM 2

AutoCAD SHX Text C3113

AutoCAD SHX Text

TOILET

AutoCAD SHX Text C3125

AutoCAD SHX Text

PROCEDURE

AutoCAD SHX Text C3120

AutoCAD SHX Text

EXAM 3

AutoCAD SHX Text C3115

AutoCAD SHX Text

EXAM 10

AutoCAD SHX Text C3131

AutoCAD SHX Text

EXAM 8

AutoCAD SHX Text C3129

AutoCAD SHX Text

PATIENT CORRIDOR

AutoCAD SHX Text C3150A

AutoCAD SHX Text

PUBLIC CORRIDOR

AutoCAD SHX Text C3150F

AutoCAD SHX Text

TEAM ROOM

AutoCAD SHX Text C3132

AutoCAD SHX Text

NURSE

AutoCAD SHX Text C3114

AutoCAD SHX Text

EX. OFFICE

AutoCAD SHX Text C3129

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. STAIR

AutoCAD SHX Text

NO. 6

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. OFFICE

AutoCAD SHX Text C3130A

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. CONF.

AutoCAD SHX Text C3130F

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. ---

AutoCAD SHX Text C----

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. OFFICE

AutoCAD SHX Text C3130C

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. OFFICE

AutoCAD SHX Text C3135

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. COPY

AutoCAD SHX Text C3127

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. OFFICE

AutoCAD SHX Text C3130B

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. STOR.

AutoCAD SHX Text C3128

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. KITCHEN

AutoCAD SHX Text C3133

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. OFFICE

AutoCAD SHX Text C3131

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. TLT.

AutoCAD SHX Text C3127B

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. TLT.

AutoCAD SHX Text C3128A

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. MECH.

AutoCAD SHX Text C3132

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. OFFICE

AutoCAD SHX Text C3131A

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. STOR.

AutoCAD SHX Text C3130E

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. OFFICE

AutoCAD SHX Text C3130D

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. COPY

AutoCAD SHX Text C3130C

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. REC./CORRIDORS

AutoCAD SHX Text C3127

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. CORRIDORS

AutoCAD SHX Text C3127

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text U

AutoCAD SHX Text T

AutoCAD SHX Text R

AutoCAD SHX Text Q

AutoCAD SHX Text P

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text K

AutoCAD SHX Text

EX. LOUVER

AutoCAD SHX Text

EX. LOUVER

AutoCAD SHX Text

EX. LOUVER

AutoCAD SHX Text 5" D.S.

AutoCAD SHX Text

SINK

AutoCAD SHX Text 5" D.S.

AutoCAD SHX Text

SINK

AutoCAD SHX Text P528

AutoCAD SHX Text P528

AutoCAD SHX Text P531

AutoCAD SHX Text P103

AutoCAD SHX Text P103

AutoCAD SHX Text P401

AutoCAD SHX Text P401

AutoCAD SHX Text P528

AutoCAD SHX Text P528

AutoCAD SHX Text P528

AutoCAD SHX Text P528

AutoCAD SHX Text P505

AutoCAD SHX Text P402

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P608

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P531

AutoCAD SHX Text

AutoCAD SHX Text 4"

AutoCAD SHX Text

FD-D

AutoCAD SHX Text

AutoCAD SHX Text

FD-D

AutoCAD SHX Text

AutoCAD SHX Text

FD-D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

4" SAN DN.

AutoCAD SHX Text

MECH. ROOM

AutoCAD SHX Text C5002

AutoCAD SHX Text

EX. FEC

AutoCAD SHX Text C3134A

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. ---

AutoCAD SHX Text C----

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. KITCHEN

AutoCAD SHX Text C3133

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. MECH.

AutoCAD SHX Text C3132

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. REC./CORRIDORS

AutoCAD SHX Text C3127

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. LOUVER

AutoCAD SHX Text

EX. LOUVER

AutoCAD SHX Text

EX. LOUVER

AutoCAD SHX Text 5" D.S.

AutoCAD SHX Text

4" SAN DN.

AutoCAD SHX Text

PD101

AutoCAD SHX Text

THIRD FLOOR PLAN - C-WING PLUMBING DEMO PLAN

AutoCAD SHX Text Freight Elevator S-6

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text William S. Middleton Memorial VA, Madison WI

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text N

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text Not to Scale

AutoCAD SHX Text Basement thru 3rd floor

AutoCAD SHX Text Machine Room -4th floor

AutoCAD SHX Text Machine Room C4144A

AutoCAD SHX Text

PENTHOUSE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text ABATE PLUMBING INSULATION AND FITTINGS UNDER THE ABATEMENT SCOPE OF WORK REMOVE, CUT AND CAP EXISTING DOMESTIC HOT WATER AND COLD WATER ABOVE CEILING OF KITCHEN SHOWN HATCHED. CAP VENT PIPING ABOVE CEILING CAP DRAIN PIPING BELOW FLOOR. INSTALL STEEL COVER PLATE

AutoCAD SHX Text D1.

AutoCAD SHX Text D2.

AutoCAD SHX Text D3.

AutoCAD SHX Text D4.

AutoCAD SHX Text D5.

AutoCAD SHX Text D6.

AutoCAD SHX Text VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY THE ARCHITECT OR VA COR OF CONFLICTS PRIOR TO PROCEEDING. ALL ITEMS BEING REMOVED SHALL REMAIN THE PROPERTY OF THE OWNER UNTIL CONFIRMATION HAS BEEN MADE AS TO WHETHER THE OWNER WILL RETAIN SUCH ITEMS. ALL ITEMS NOT BEING RETAINED BY THE OWNER OR DESIGNATED ON THE DRAWINGS TO BE RELOCATED OR REINSTALLED SHALL BE COMPLETELY REMOVED FROM THE SITE AND PROPERLY DISPOSED OF. ALL ATTEMPTS TO DEPICT CURRENT CONDITIONS AS SHOWN ON THE DRAWINGS WERE MADE TO BEST OF THE ARCHITECTS KNOWLEDGE OF EXISTING CONDITIONS AND OTHER RESOURCES SUCH AS SITE INVESTIGATIONS AND REVIEW OF PREVIOUS DRAWINGS. REFER TO ELECTRICAL AND ARCHITECURAL PLANS FOR RESPECTIVE DEMOLITION INFORMATION. ASSURE THAT INTERRUPTIONS ARE KEPT TO A MINUMUM AND PLANNED ACCORDINGLY TO EXISTING EQUIPMENT IN THE PROJECT AREA UNLESS INDICATED. CONTRACTOR TO FURTHER ENSURE WHERE DEMOLITION WOULD EFFECT OPERATIONS OF OTHER AREAS OUTSIDE OF THE PROJECT; THAT THEY SHALL NOTIFY THOSE INDIVIDUALS RESPECTIVELY FOR ANY SHUTDOWNS OR OPERATIONAL DOWN TIME CONSTRAINTS. PHASING WORK FOR NIGHTS AND WEEKENDS. SEE GOO4

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1 1/4

1 1/4

1 1/41

1 1/41 1/2

1 1/22

2 2

1 1/2 1 1/2

1 1

/4 1 1

/41 1 /4

1 1 /4

2222 2

1 1 /4

1 1

1 1 /4

1 1

1 1 /4

1 1/4

1 1 /2

1 1 /2

1 1

1 1 /4

1 1 /4

SPRINKLER ZONE ASSEMBLY

1 1/2 1 1/2

1 1

/4 1 1

/4

2222 2

1 1 /4

1 1 /4

1 1 /4

FIRE PROTECTION- NINTH FLOOR -

EXISTING, DEMOLITION AND NEW WORK

Elevator:

PO Box 464

Phone: 608.616.2999 Mequon, WI 53092

UPGRADE EAGLE AND FREIGHT

ELEVATORS

Email: AdamS@pec-wi.com POC: Aslam Husain

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

35% Schematic Design 10.15.2021 5.27.22

Project Number

Building Number

607-21-155

B A

C G

POC: Adam Smith

B-Core

65% Construction Documents 12.29.2021 95% Construction Documents 3.18.2022 100% Construction Documents 5.27.2022

FP100

FIRE PROTECTION - NINTH FLOOR EXISTING PLAN

GENERAL DEMOLITION NOTES:

DEMO/NEW PLAN NOTES

SCALE: 1/4" = 1'-0"

FIRE PROTECTION - SECONDARY HOIST DEMO PLAN

SCALE: 1/4" = 1'-0"

FIRE PROTECTION - SECONDARY HOIST NEW WORK PLAN

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text B9002

AutoCAD SHX Text P1

AutoCAD SHX Text S5

AutoCAD SHX Text P2

AutoCAD SHX Text P3

AutoCAD SHX Text P4

AutoCAD SHX Text

HOIST BEAM

AutoCAD SHX Text

AutoCAD SHX Text Eagle Elevators-P1,2,3,4

AutoCAD SHX Text Freight Elevator S-5

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text William S. Middleton Memorial VA, Madison WI

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text N

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text Not to Scale

AutoCAD SHX Text Ground thru 8th floor

AutoCAD SHX Text Basement thru 8th floor

AutoCAD SHX Text 9th flr. Machine Room-B9002

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text D1.

AutoCAD SHX Text D2.

AutoCAD SHX Text D3.

AutoCAD SHX Text D4.

AutoCAD SHX Text D5.

AutoCAD SHX Text REMOVE ALL PIPING AND SPRINKLER LINES IN SECONDARY HOISTWAY BELOW B9002 AND PRIMARY HOISTWAY ASSOCIATED WITH ELEVATOR S5 CAP PIPE AT WALL INTERNAL OR EXTERNAL- FILL VOIDS WITH FIRE STOPPING MATERIAL AS APPLICABLE

AutoCAD SHX Text VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY THE ARCHITECT OR VA COR OF CONFLICTS PRIOR TO PROCEEDING. ALL ITEMS NOT BEING RETAINED BY THE OWNER OR DESIGNATED ON THE DRAWINGS TO BE RELOCATED OR REINSTALLED SHALL BE COMPLETELY REMOVED FROM THE SITE AND PROPERLY DISPOSED OF. ALL ATTEMPTS TO DEPICT CURRENT CONDITIONS AS SHOWN ON THE DRAWINGS WERE MADE TO BEST OF THE ARCHITECTS KNOWLEDGE OF EXISTING CONDITIONS AND OTHER RESOURCES SUCH AS SITE INVESTIGATIONS AND REVIEW OF PREVIOUS DRAWINGS. REFER TO MECHANICAL AND ELECTRICAL PLANS FOR RESPECTIVE DEMOLITION INFORMATION. CONTRACTOR TO FURTHER ENSURE WHERE DEMOLITION WOULD EFFECT OPERATIONS OF OTHER AREAS OUTSIDE OF THE PROJECT; THAT THEY SHALL NOTIFY THOSE INDIVIDUALS RESPECTIVELY FOR ANY SHUTDOWNS OR OPERATIONAL DOWN TIME CONSTRAINTS.

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

RETAIN ALL PIPING AND SPRINKLER LINES IN MACHINE ROOM B9002

S6

2 1/2

1" 8'-8"

1.5" 2'-8"

1"1'-2" 1"1'-2"

1"1'-2"

3" 8'-5"

1" 4' -6

SPRINKLER ZONE ASSEMBLY

2 1/2

SPRINKLER ZONE ASSEMBLY

FIRE PROTECTION- 4RTH FLOOR AND 5TH

FLOOR- DEMOLITION AND NEW WORK

Elevator:

PO Box 464

Phone: 608.616.2999 Mequon, WI 53092

UPGRADE EAGLE AND FREIGHT

ELEVATORS

Email: AdamS@pec-wi.com POC: Aslam Husain

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

35% Schematic Design 10.15.2021 5.27.22

Project Number

Building Number

607-21-155

B A

C G

POC: Adam Smith

B-Core

65% Construction Documents 12.29.2021 95% Construction Documents 3.18.2022 100% Construction Documents 5.27.2022

FP101

FIRE PROTECTION - 4TH FLOOR DEMOLITION PLAN

GENERAL DEMOLITION NOTES:

FOURTH FLOOR DEMO PLAN NOTES

SCALE: 1/4" = 1'-0" FIRE PROTECTION - 5TH FLOOR NEW WORK PLAN

SCALE: 1/4" = 1'-0"

FIFTH FLOOR NEW PLAN NOTES

EQUIPMENT NOTES

NOTES

AutoCAD SHX Text C4136

AutoCAD SHX Text

LAB

AutoCAD SHX Text C4137

AutoCAD SHX Text

LAB

AutoCAD SHX Text C4160

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text C4140

AutoCAD SHX Text

STORAGE, EQUIPMENT

AutoCAD SHX Text C4139

AutoCAD SHX Text

LAB

AutoCAD SHX Text C4138

AutoCAD SHX Text

MECH ROOM

AutoCAD SHX Text C4143

AutoCAD SHX Text

MECH

AutoCAD SHX Text C4142

AutoCAD SHX Text

LAB

AutoCAD SHX Text C4144

AutoCAD SHX Text

ELEC VAULT

AutoCAD SHX Text C4144A

AutoCAD SHX Text

ELEVATOR MACHINE

AutoCAD SHX Text C4144B

AutoCAD SHX Text

ELEC VAULT

AutoCAD SHX Text C4149C

AutoCAD SHX Text

OFFICE, STAFF

AutoCAD SHX Text C4146

AutoCAD SHX Text

LAB, RESEARCH

AutoCAD SHX Text Q

AutoCAD SHX Text P

AutoCAD SHX Text C5002

AutoCAD SHX Text C5003

AutoCAD SHX Text Q

AutoCAD SHX Text P

AutoCAD SHX Text Q

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Eagle Elevators-P1,2,3,4

AutoCAD SHX Text Freight Elevator S-5

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text William S. Middleton Memorial VA, Madison WI

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text N

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text Not to Scale

AutoCAD SHX Text Ground thru 8th floor

AutoCAD SHX Text Basement thru 8th floor

AutoCAD SHX Text 9th flr. Machine Room-B9002

AutoCAD SHX Text

AutoCAD SHX Text D1.

AutoCAD SHX Text D2.

AutoCAD SHX Text D3.

AutoCAD SHX Text D4.

AutoCAD SHX Text D5.

AutoCAD SHX Text REMOVE ALL PIPING AND SPRINKLER LINES IN 4RTH FL0OR MACHINE ROOM AS WELL AS IN PRIMARY HOISTWAY SHAFT ASSOCIATED WITH ELEVATOR S6 CAP PIPE AT WALL INTERNAL OR EXTERNAL- FILL VOIDS WITH FIRE STOPPING MATERIAL AS APPLICABLE. VERIFY CONNECTION IN THE FIELD.

AutoCAD SHX Text VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY THE ARCHITECT OR VA COR OF CONFLICTS PRIOR TO PROCEEDING. ALL ITEMS NOT BEING RETAINED BY THE OWNER OR DESIGNATED ON THE DRAWINGS TO BE RELOCATED OR REINSTALLED SHALL BE COMPLETELY REMOVED FROM THE SITE AND PROPERLY DISPOSED OF. ALL ATTEMPTS TO DEPICT CURRENT CONDITIONS AS SHOWN ON THE DRAWINGS WERE MADE TO BEST OF THE ARCHITECTS KNOWLEDGE OF EXISTING CONDITIONS AND OTHER RESOURCES SUCH AS SITE INVESTIGATIONS AND REVIEW OF PREVIOUS DRAWINGS. REFER TO MECHANICAL AND ELECTRICAL PLANS FOR RESPECTIVE DEMOLITION INFORMATION. CONTRACTOR TO FURTHER ENSURE WHERE DEMOLITION WOULD EFFECT OPERATIONS OF OTHER AREAS OUTSIDE OF THE PROJECT; THAT THEY SHALL NOTIFY THOSE INDIVIDUALS RESPECTIVELY FOR ANY SHUTDOWNS OR OPERATIONAL DOWN TIME CONSTRAINTS.

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text CONNECT NEW SPRINKLER PIPING TO EXISTING BRANCH PIPING IN 5TH FLOOR PENTHOUSE. ROUTE AND PROVIDE MINIMUM SPRINKLER DESIGN COVERAGE TO MACHINE ROOM. AVOID ANY OBSTRUCTIONS ABOVE MACHINE MOTOR. PROVIDE STANDARD RESPONSE SPRINKLERS IN MACHINE ROOM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text GENERAL NOTES: 1. FIELD INVESTIGATION IS REQUIRED TO VERIFY EXISTING FIELD INVESTIGATION IS REQUIRED TO VERIFY EXISTING PIPE SIZES, ELEVATIONS AND MAIN ROUTING. MANY CONGESTED AREAS ARE PRESENT, AND WILL REQUIRE MODIFIED BRANCH ROUTING. 2. DEMOLITION AND NEW WORK TO BE DONE IN PHASES. DEMOLITION AND NEW WORK TO BE DONE IN PHASES. MAINTAIN COVERAGE TO ALL AREAS OF AT ALL TIMES. MINIMIZE SHUTDOWNS TO THE GREATEST EXTENT POSSIBLE. COORDINATE WORK WITH OTHER TRADES.

AutoCAD SHX Text NO DESCRIPTION DESCRIPTION 1 SPRINKLER STAND PIPE HEADS - 1" CONNECTIONS - CHROME SPRINKLER STAND PIPE HEADS - 1" CONNECTIONS - CHROME SEMI-RECESS QUICK RESPONSE TYPE 2 PIPING AND FITTINGS SHALL BE IN ACCORDANCE WITH VA SPECIFICATIONS 21 PIPING AND FITTINGS SHALL BE IN ACCORDANCE WITH VA SPECIFICATIONS 21 13 13 AND NFPA 13. STANDPIPE TO BE IN ACCORDANCE WITH NFPA 14. PIPE SIZES 2 INCHES AND SMALLER TO BE SCHEDULE 40, THREADED END CONNECTIONS. PIPE SIZE 2 " AND LARGER TO BE BLACK STEEL, SCHEDULE 12" AND LARGER TO BE BLACK STEEL, SCHEDULE 10 MINIMUM WITH GROOVED CONNECTIONS. REFERENCE 21 13 13 FOR SPECIFICS 3 PIPE HANGERS AND SUPPORTS TO CONFORM TO NFPA 14. PIPE HANGERS AND SUPPORTS TO CONFORM TO NFPA 14. 4 WET SYSTEM CONTROL VALVE SHALL BE UL LISTED AN FM APPROVED FOR WET SYSTEM CONTROL VALVE SHALL BE UL LISTED AN FM APPROVED FOR FIRE PROTECTION INSTALLATIONS WITH MINIMUM 175 PSIG RATING. 5. SPRINKLER HEADS TO BE FM APPROVED QUICK RESPONSE TYPE.SPRINKLER HEADS TO BE FM APPROVED QUICK RESPONSE TYPE.

AutoCAD SHX Text

1. CONTRACTOR SHALL DESIGN, PROCURE, CONSTRUCT AND COMMISSION CONTRACTOR SHALL DESIGN, PROCURE, CONSTRUCT AND COMMISSION AN INTEGRATED FIRE PROTECTION SYSTEM IN PER THE LISTED SPECIFICATIONS AND GENERAL INTENTION OF SERVING A HOSPITAL BUILDING IN COMPLIANCE WITH ALL NFPA CODES AND LOCAL REQUIREMENTS INCLUDING BUT NOT LIMITED TO THE FOLLOWING: A. HAZARD CLASSIFICATION OF THE BUILDING AND SPECIFIC AREAS BASED ON ARCHITECTURAL DRAWINGS. FOR DUAL USE OR MULTI-ROLE AREAS USE STRICTER OF THE APPLICABLE CLASSIFICATIONS. B. SPRINKLER, TESTING AND DRAIN PIPING INCLUDING FLOW SWITCHES, ISOLATION VALVES, TAMPER SWITCH, PRESSURE GAUGE AND OTHER COMPONENTS. C. FIRE EXTINGUISHER CABINETS (FEC)TO BE PROVIDED IN EXISTING SPACES AS SHOWN ON THE DRAWINGS. D. IDENTIFICATION SIGNS AND HYDRAULIC PLACARDS PER NFPA 14. E. FREEZE PROTECTION FEATURES SHALL BE INCORPORATED AS REQUIRED. F. FIRE ALARM AND ANNUNCIATION SYSTEM SHOWN ON FA-100. 2. ALL ATTEMPTS TO IDENTIFY EXISTING SPRINKLER DISTRIBUTION AS ALL ATTEMPTS TO IDENTIFY EXISTING SPRINKLER DISTRIBUTION AS SHOWN HAS BEEN MADE TO THE BEST OF THE A/E OF KNOWN SITE FIELD CONDITIONS AND AS BUILTS. CONTRACTOR TO REVIEW DEFINED ZONES, SPRINKLER LOCATIONS, EXISTING PIPING MAIN AND BRANCHES, PIPE SIZES INDICATED WITHIN RENOVATION ZONE TO BE REDISTRIBUTED INTO NEW LAYOUT AND MAKE ADJUSTMENTS AS NECESSARY TO COMPLETE THE REQUIRED PER REGULATIONS AND SPECIFICATIONS. 3. DESIGN OF SPRINKLER SYSTEM AND SHOP DRAWINGS SHALL BE DESIGN OF SPRINKLER SYSTEM AND SHOP DRAWINGS SHALL BE COMPLETED BY A LICENSED ENGINEER PRACTICING IN THE FIELD OF FIRE PROTECTION ENGINEERING 4. INSTALLER SHALL POSSESS A VALID STATE CONTRACTOR'S LICENSE AND INSTALLER SHALL POSSESS A VALID STATE CONTRACTOR'S LICENSE AND BE TRAINED IN WET SYSTEM FIRE PROTECTION INSTALLATIONS. 5. ALL EQUIPMENT AND DEVICES SHALL BE OF A MAKE AND TYPE LISTED ALL EQUIPMENT AND DEVICES SHALL BE OF A MAKE AND TYPE LISTED BY UL AND APPROVED BY FM- SPRINKLERS SHALL BE QUICK RESPONSE 6. DESIGN, MATERIALS, EQUIPMENT, INSTALLATION AND TESTING OF THE DESIGN, MATERIALS, EQUIPMENT, INSTALLATION AND TESTING OF THE SYSTEM SHALL BE IN ACCORDANCE WITH NFPA 13. 7. CONTRACTOR SHALL PROCURE, CONSTRUCT AND COMMISSION CONTRACTOR SHALL PROCURE, CONSTRUCT AND COMMISSION INTEGRATED FIRE PROTECTION SYSTEM. 8. CONTRACTOR SHALL PROVIDE AND SUBMIT HYDRAULIC CALCULATIONS CONTRACTOR SHALL PROVIDE AND SUBMIT HYDRAULIC CALCULATIONS USING THE MAIN WATER PRESSURE AND FLOW RATE PER NFPA 13. REFER TO SPEC SECTION 21-13-13.

AutoCAD SHX Text N

N

FIRE ALARM- NINTH FLOOR - EXISTING

DEMOLITION AND NEW PLAN WORK

Elevator:

PO Box 464

Phone: 608.616.2999 Mequon, WI 53092

UPGRADE EAGLE AND FREIGHT

ELEVATORS

Email: AdamS@pec-wi.com POC: Aslam Husain

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

35% Schematic Design 10.15.2021 5.27.22

Project Number

Building Number

607-21-155

B A

C G

POC: Adam Smith

B-Core

65% Construction Documents 12.29.2021 95% Construction Documents 3.18.2022 100% Construction Documents 5.27.2022

FA100

ELECTRICAL FIRE ALARM - NINTH FLOOR DEMO PLAN

GENERAL DEMOLITION NOTES:

DEMO PLAN NOTES

NEW WORK PLAN NOTES

SCALE: 1/4" = 1'-0"

GENERAL NOTES:

ELECTRICAL FIRE ALARM - SECONDARY HOIST DEMO PLAN

SCALE: 1/4" = 1'-0"

ELECTRICAL FIRE ALARM - NINTH FLOOR NEW PLAN

SCALE: 1/4" = 1'-0"

NEW WORK ALARM NOTES

AutoCAD SHX Text S

AutoCAD SHX Text 3:M6-1

AutoCAD SHX Text

CM

AutoCAD SHX Text 3:M6-72

AutoCAD SHX Text

CM

AutoCAD SHX Text 3:M6-73

AutoCAD SHX Text

CM

AutoCAD SHX Text 3:M6-75

AutoCAD SHX Text

IAM

AutoCAD SHX Text 3:M6-76

AutoCAD SHX Text H

AutoCAD SHX Text 3:M6-79

AutoCAD SHX Text S

AutoCAD SHX Text 3:M6-80

AutoCAD SHX Text S

AutoCAD SHX Text 3:M6-81

AutoCAD SHX Text S

AutoCAD SHX Text 3:M6-82

AutoCAD SHX Text S

AutoCAD SHX Text 3:M6-83

AutoCAD SHX Text

CM

AutoCAD SHX Text 3:M6-87

AutoCAD SHX Text

IAM

AutoCAD SHX Text 3:M6-88

AutoCAD SHX Text

DD

AutoCAD SHX Text 3:M6-90

AutoCAD SHX Text

CM

AutoCAD SHX Text 3:M6-94

AutoCAD SHX Text

IAM

AutoCAD SHX Text 3:M6-95

AutoCAD SHX Text

CM

AutoCAD SHX Text 3:M6-96

AutoCAD SHX Text

IAM

AutoCAD SHX Text 3:M6-97

AutoCAD SHX Text 3:M6-107

AutoCAD SHX Text 3:M6-105

AutoCAD SHX Text 3:M6-103

AutoCAD SHX Text

CM

AutoCAD SHX Text

CM

AutoCAD SHX Text 3:M6-114

AutoCAD SHX Text H

AutoCAD SHX Text 3:M6-132

AutoCAD SHX Text H

AutoCAD SHX Text 3:M6-129

AutoCAD SHX Text S

AutoCAD SHX Text 3:M6-57

AutoCAD SHX Text H

AutoCAD SHX Text 3:M6-131

AutoCAD SHX Text H

AutoCAD SHX Text 3:M6-130

AutoCAD SHX Text H

AutoCAD SHX Text 3:M6-135

AutoCAD SHX Text H

AutoCAD SHX Text 3:M6-133

AutoCAD SHX Text H

AutoCAD SHX Text 3:M6-134

AutoCAD SHX Text

CM

AutoCAD SHX Text

CM

AutoCAD SHX Text 3:M6-109

AutoCAD SHX Text 3:M6-108

AutoCAD SHX Text

MM

AutoCAD SHX Text

CM

AutoCAD SHX Text B9002

AutoCAD SHX Text P1

AutoCAD SHX Text S5

AutoCAD SHX Text P2

AutoCAD SHX Text P3

AutoCAD SHX Text P4

AutoCAD SHX Text

HOIST BEAM

AutoCAD SHX Text

DS-P2

AutoCAD SHX Text

DS-P3

AutoCAD SHX Text

DS-P4

AutoCAD SHX Text

DS-P1

AutoCAD SHX Text

GFI

AutoCAD SHX Text S

AutoCAD SHX Text H

AutoCAD SHX Text S

AutoCAD SHX Text H

AutoCAD SHX Text S

AutoCAD SHX Text H

AutoCAD SHX Text S

AutoCAD SHX Text H

AutoCAD SHX Text S

AutoCAD SHX Text H

AutoCAD SHX Text S

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text 3:M6-58

AutoCAD SHX Text S

AutoCAD SHX Text 3:M6-59

AutoCAD SHX Text

JB

AutoCAD SHX Text

SD

AutoCAD SHX Text

4RTH AND 5TH FLOORS

AutoCAD SHX Text B9002

AutoCAD SHX Text P1

AutoCAD SHX Text S5

AutoCAD SHX Text P2

AutoCAD SHX Text P3

AutoCAD SHX Text P4

AutoCAD SHX Text

HOIST BEAM

AutoCAD SHX Text

DS-S5

AutoCAD SHX Text

DS-P1

AutoCAD SHX Text

DS-P2

AutoCAD SHX Text

DS-P3

AutoCAD SHX Text

DS-P4

AutoCAD SHX Text

PIT S5

AutoCAD SHX Text Eagle Elevators-P1,2,3,4

AutoCAD SHX Text Freight Elevator S-5

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text William S. Middleton Memorial VA, Madison WI

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text N

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text Not to Scale

AutoCAD SHX Text Ground thru 8th floor

AutoCAD SHX Text Basement thru 8th floor

AutoCAD SHX Text 9th flr. Machine Room-B9002

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text D1.

AutoCAD SHX Text D2.

AutoCAD SHX Text D3.

AutoCAD SHX Text D4.

AutoCAD SHX Text D5.

AutoCAD SHX Text EXISTING ELEVATOR DISCONNECTS WILL BE REMOVED AND PROVIDED NEW. SET ASIDE FOR REINSTALLATION ALL FIRE ALARM WIRING CONNECTIONS, IF REUSABLE. PROVIDE NEW AND INSTALL IF NECESSARY. ALL ASSOCIATED MOTORS, ELECTRICAL PANELBOARDS, TRANSFORMERS, ASSOCIATED DEVICES, DUCT BANKS AND POWER CABLES WILL BE REMOVED. ALL CONTROLS AND CONTROL CABINETS FOR THE MODERNIZATION OF ELEVATOR MACHINE ROOM WILL BE REMOVED. SET ASIDE FOR REINSTALLATION ALL FIRE ALARM WIRING CONNECTIONS, IF REUSABLE. PROVIDE NEW AND INSTALL IF NECESSARY. REMOVE ELECTRICAL WIRING, CONDUIT AND DEVICES ASSOCIATED WITH MECHANICAL DAMPERS TO BE REMOVED. SEE MECHANICAL AND ELECTRICAL DEMO REMOVE ABANDONED WIRING, CONDUIT AND DEVICES ASSOCIATED WITH FIRE ALARMS AS NOTED ON B9002. ADDITIONALLY, REMOVED 3 ABANDONED RED FIRE ALARM REMOVED 3 ABANDONED RED FIRE ALARM J-BOXES THAT HAVE RED WIRE AND/OR CONDUIT CONNECTING THEM LOCATED BETWEEN FOURTH & FIFTH & FIFTH FLOORS ON THE NORTH WALL. REMOVE CONDUIT AND WIRE FROM SHAFT BACK TO NEAREST J-BOX. REMOVE ALL WIRING, CONDUIT AND DEVICES ASSOCIATED WITH FIRE ALARMS AS NOTED IN SECONDARY HOISTWAY BELOW B9002 AND PRIMARY HOISTWAY ASSOCIATED WITH ELEVATOR S5

AutoCAD SHX Text VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY THE ARCHITECT OR VA COR OF CONFLICTS PRIOR TO PROCEEDING. ALL ITEMS NOT BEING RETAINED BY THE OWNER OR DESIGNATED ON THE DRAWINGS TO BE RELOCATED OR REINSTALLED SHALL BE COMPLETELY REMOVED FROM THE SITE AND PROPERLY DISPOSED OF. ALL ATTEMPTS TO DEPICT CURRENT CONDITIONS AS SHOWN ON THE DRAWINGS WERE MADE TO BEST OF THE ARCHITECTS KNOWLEDGE OF EXISTING CONDITIONS AND OTHER RESOURCES SUCH AS SITE INVESTIGATIONS AND REVIEW OF PREVIOUS DRAWINGS. REFER TO MECHANICAL AND ELECTRICAL PLANS FOR RESPECTIVE DEMOLITION INFORMATION. CONTRACTOR TO FURTHER ENSURE WHERE DEMOLITION WOULD EFFECT OPERATIONS OF OTHER AREAS OUTSIDE OF THE PROJECT; THAT THEY SHALL NOTIFY THOSE INDIVIDUALS RESPECTIVELY FOR ANY SHUTDOWNS OR OPERATIONAL DOWN TIME CONSTRAINTS. FIRE ALARM J-BOXES BETWEEN 4TH & 5TH FLOORS ON THE NORTH WALL THAT HAVE RED WIRE AND/OR CONDUIT CONNECTING THEM. REMOVE CONDUIT AND WIRE FROM SHAFT TO NEAREST J-BOX.

AutoCAD SHX Text HOOK UP NEW DISCONNECTS WITH SHUNT TRIP CONTACTS. ATTACH TO FIRE ALARM SYSTEM. REATTACH ALL FIRE ALARM WIRING PERTAINING TO ALL MODERNIZE ELEVATOR EQUIPMENT BEING INSTALLED. CONNECT ALL NEW ELEVATORS SYSTEMS TO THE EXISTING HOSPITAL MAIN FIRE ALARM SYSTEM & PANELS. INCLUDING THE ELEVATOR FIRE SERVICE, SMOKE & FIRE ALARMS, AUXILIARY FIRE ALARM SYSTEMS & PANEL AND FIREMAN'S RECALL FIRE ALARM PROTECTION CONTRACTOR TO PROVIDE NEW POINTS, CONNECTIONS, SOFTWARE AND HARDWARE FOR A COMPLETE SYSTEM PER ASME ELEVATOR CODES, NFPA AND CITY OF MADISON FIRE DEPT REQUIREMENTS.

AutoCAD SHX Text

1. SEE SHEET E001 FOR SYMBOLS, ABBREVIATIONS AND NOTES SEE SHEET E001 FOR SYMBOLS, ABBREVIATIONS AND NOTES 2. EXISTING FIRE ALARM SYSTEM FOR THIS FACILITY IS SIMPLEX. CONTRACTOR EXISTING FIRE ALARM SYSTEM FOR THIS FACILITY IS SIMPLEX. CONTRACTOR TO WORK WITH SIMPLEX 4100 SYSTEMS FOR CONNECTIONS TO EXISTING FIRE ALARM SYSTEM. 3. EXISTING DEVICES SHALL BE RETAINED TO THE GREATEST EXTENT POSSIBLE EXISTING DEVICES SHALL BE RETAINED TO THE GREATEST EXTENT POSSIBLE UNLESS OTHERWISE NOTED. 4. THE CONTRACTOR SHALL REPROGRAM, TEST AND CERTIFY FIRE ALARM THE CONTRACTOR SHALL REPROGRAM, TEST AND CERTIFY FIRE ALARM SYSTEM AFTER NEW ELEVATOR SHUNT TRIP AND CONTROLS HAVE BEEN RE-CONNECTED. 5. ALL CABLING AND TIE-INS TO FIRE ALARM SYSTEM SHALL BE INSTALLED ALL CABLING AND TIE-INS TO FIRE ALARM SYSTEM SHALL BE INSTALLED BY CONTRACTOR. 6. FIRE ALARMS SHALL MEET THE REQUIREMENTS OF NFPA 72.FIRE ALARMS SHALL MEET THE REQUIREMENTS OF NFPA 72.

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text D6.

AutoCAD SHX Text

AutoCAD SHX Text PROVIDE AND INSTALL WINLAND ENVIROMENTAL SECURITY, ELECTRONIC WATER DETECTION DEVICE WATERBUG WB-800 IN PIT S5. WATER INTRUSION DEVICE TO MATCH EXISTING HOSPITAL ELECTRONIC WATER DETECTION DEVICE SYSTEMS. PROVIDE ALL WIRING AND CONDUIT TO CONNECT TO THE EXISTING HOSPITAL SIMPLEX FIRE ALARM PANEL. COORDINATE WORK WITH ELEVATOR CONTRACTOR.

AutoCAD SHX Text

AutoCAD SHX Text

S6

C O

R R

ID

O

R C

N

EW

L O

BB

Y

C

5'

6'

3"

7'

1"

6'

Elevator:

PO Box 464

Phone: 608.616.2999 Mequon, WI 53092

UPGRADE EAGLE AND FREIGHT

ELEVATORS

Email: AdamS@pec-wi.com POC: Aslam Husain

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

35% Schematic Design 10.15.2021 5.27.22

Project Number

Building Number

607-21-155

B A

C G

POC: Adam Smith

B-Core

65% Construction Documents 12.29.2021 95% Construction Documents 3.18.2022 100% Construction Documents 5.27.2022

FA101

FIRE ALARM - FOURTH FLOOR DEMOLITION PLAN

SCALE: 1/4" = 1'-0"

FIRE ALARM - FIFTH FLOOR NEW WORK PLAN

SCALE: 1/4" = 1'-0"

GENERAL DEMOLITION NOTES:

FOURTH FLOOR DEMO PLAN NOTES

FIFTH FLOOR NEW WORK PLAN NOTES

GENERAL NOTES:

FIRE ALARM-THIRD,FOURTH AND FIFTH

FLOOR - DEMOLITION AND NEW PLAN WORK

FIRE ALARM - THIRD FLOOR NEW WORK PLAN

SCALE: 1/4" = 1'-0"

THIRD FLOOR NEW WORK PLAN NOTES

AutoCAD SHX Text C4136

AutoCAD SHX Text

LAB

AutoCAD SHX Text C4137

AutoCAD SHX Text

LAB

AutoCAD SHX Text C4160

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text C4140

AutoCAD SHX Text

STORAGE, EQUIPMENT

AutoCAD SHX Text C4139

AutoCAD SHX Text

LAB

AutoCAD SHX Text C4138

AutoCAD SHX Text

MECH ROOM

AutoCAD SHX Text C4143

AutoCAD SHX Text

MECH

AutoCAD SHX Text C4142

AutoCAD SHX Text

LAB

AutoCAD SHX Text C4144

AutoCAD SHX Text

ELEC VAULT

AutoCAD SHX Text C4144A

AutoCAD SHX Text

ELEVATOR MACHINE

AutoCAD SHX Text C4144B

AutoCAD SHX Text

ELEC VAULT

AutoCAD SHX Text C4149C

AutoCAD SHX Text

OFFICE, STAFF

AutoCAD SHX Text C4146

AutoCAD SHX Text

LAB, RESEARCH

AutoCAD SHX Text Q

AutoCAD SHX Text P

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text H

AutoCAD SHX Text H

AutoCAD SHX Text 3:M5-6

AutoCAD SHX Text 3:M5-7

AutoCAD SHX Text 3:M5-8

AutoCAD SHX Text 3:M5-84

AutoCAD SHX Text 3:M5-85

AutoCAD SHX Text 3:M5-77

AutoCAD SHX Text 3:M5-79

AutoCAD SHX Text 3:M5-81

AutoCAD SHX Text 3:M5-82

AutoCAD SHX Text 3:M5-122

AutoCAD SHX Text

CM

AutoCAD SHX Text

CM

AutoCAD SHX Text

CM

AutoCAD SHX Text

CM

AutoCAD SHX Text

CM

AutoCAD SHX Text 3:M5-80

AutoCAD SHX Text

MM

AutoCAD SHX Text 3:M5-83

AutoCAD SHX Text

CM

AutoCAD SHX Text

DS-S6

AutoCAD SHX Text

CONT.

AutoCAD SHX Text

DS

AutoCAD SHX Text Q

AutoCAD SHX Text P

AutoCAD SHX Text

DS-S6

AutoCAD SHX Text

CONT.

AutoCAD SHX Text 3:M5-122

AutoCAD SHX Text

CM

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text H

AutoCAD SHX Text H

AutoCAD SHX Text 3:M5-6

AutoCAD SHX Text 3:M5-7

AutoCAD SHX Text 3:M5-8

AutoCAD SHX Text 3:M5-84

AutoCAD SHX Text 3:M5-85

AutoCAD SHX Text 3:M5-77

AutoCAD SHX Text 3:M5-79

AutoCAD SHX Text 3:M5-81

AutoCAD SHX Text 3:M5-82

AutoCAD SHX Text

CM

AutoCAD SHX Text

CM

AutoCAD SHX Text

CM

AutoCAD SHX Text

CM

AutoCAD SHX Text 3:M5-80

AutoCAD SHX Text

MM

AutoCAD SHX Text 3:M5-83

AutoCAD SHX Text

CM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EX. FEC

AutoCAD SHX Text C3134A

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text C3134

AutoCAD SHX Text

EX. STAIR

AutoCAD SHX Text

NO. 6

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. ---

AutoCAD SHX Text C----

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. OFFICE

AutoCAD SHX Text C3135

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. STOR.

AutoCAD SHX Text C3128

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. KITCHEN

AutoCAD SHX Text C3133

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. MECH.

AutoCAD SHX Text C3132

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. REC./CORRIDORS

AutoCAD SHX Text C3127

AutoCAD SHX Text

DO NOT FILL IN THESE FIELDS

AutoCAD SHX Text

EX. LOUVER

AutoCAD SHX Text

EX. LOUVER

AutoCAD SHX Text

EX. LOUVER

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text Freight Elevator S-6

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text William S. Middleton Memorial VA, Madison WI

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text N

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text Not to Scale

AutoCAD SHX Text Basement thru 3rd floor

AutoCAD SHX Text Machine Room -4th floor

AutoCAD SHX Text Machine Room C4144A

AutoCAD SHX Text

PENTHOUSE

AutoCAD SHX Text

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text D1.

AutoCAD SHX Text D2.

AutoCAD SHX Text D3.

AutoCAD SHX Text D4.

AutoCAD SHX Text D5.

AutoCAD SHX Text EXISTING ELEVATOR DISCONNECTS WILL BE REMOVED AND PROVIDED NEW. ALL ASSOCIATED MOTORS, ELECTRICAL PANELBOARDS, TRANSFORMERS, ASSOCIATED DEVICES, DUCT BANKS AND POWER CABLES WILL BE REMOVED. ALL CONTROLS AND CONTROL CABINETS FOR THE MODERNIZATION OF ELEVATOR MACHINE ROOM WILL BE REMOVED. SET ASIDE RELOCATE FOR REINSTALLATION ALL FIRE ALARM WIRING CONNECTIONS, IF REUSABLE. PROVIDE NEW AND INSTALL IF NECESSARY. REMOVE ALL WIRING, CONDUIT AND DEVICES ASSOCIATED WITH FIRE ALARMS AS NOTED IN FOURTH FLOOR MACHINE ROOM SPACE AS WELL AS PRIMARY HOISTWAY ASSOCIATED WITH ELEVATOR S6

AutoCAD SHX Text VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY THE ARCHITECT OR VA COR OF CONFLICTS PRIOR TO PROCEEDING. ALL ITEMS NOT BEING RETAINED BY THE OWNER OR DESIGNATED ON THE DRAWINGS TO BE RELOCATED OR REINSTALLED SHALL BE COMPLETELY REMOVED FROM THE SITE AND PROPERLY DISPOSED OF. ALL ATTEMPTS TO DEPICT CURRENT CONDITIONS AS SHOWN ON THE DRAWINGS WERE MADE TO BEST OF THE ARCHITECTS KNOWLEDGE OF EXISTING CONDITIONS AND OTHER RESOURCES SUCH AS SITE INVESTIGATIONS AND REVIEW OF PREVIOUS DRAWINGS. REFER TO MECHANICAL AND ELECTRICAL PLANS FOR RESPECTIVE DEMOLITION INFORMATION. CONTRACTOR TO FURTHER ENSURE WHERE DEMOLITION WOULD EFFECT OPERATIONS OF OTHER AREAS OUTSIDE OF THE PROJECT; THAT THEY SHALL NOTIFY THOSE INDIVIDUALS RESPECTIVELY FOR ANY SHUTDOWNS OR OPERATIONAL DOWN TIME CONSTRAINTS.

AutoCAD SHX Text PROVIDE FIRE ALARMS IN NEW MACHINE ROOM HOOK UP NEW DISCONNECTS WITH SHUNT TRIP CONTACTS. ATTACH TO FIRE ALARM SYSTEM. ATTACH ALL FIRE ALARM WIRING PERTAINING TO ALL MODERNIZE ELEVATOR EQUIPMENT BEING INSTALLED. CONNECT ALL NEW ELEVATORS SYSTEMS TO THE EXISTING HOSPITAL MAIN FIRE ALARM SYSTEM & PANELS. INCLUDING THE ELEVATOR FIRE SERVICE, SMOKE & FIRE ALARMS, AUXILIARY FIRE ALARM SYSTEMS & PANEL AND FIREMAN'S RECALL FIRE ALARM PROTECTION CONTRACTOR TO PROVIDE NEW POINTS, CONNECTIONS, SOFTWARE AND HARDWARE FOR A COMPLETE SYSTEM PER ASME ELEVATOR CODES AND NFPA CODES

AutoCAD SHX Text

1. SEE SHEET E001 FOR SYMBOLS, ABBREVIATIONS AND NOTES SEE SHEET E001 FOR SYMBOLS, ABBREVIATIONS AND NOTES 2. EXISTING FIRE ALARM SYSTEM FOR THIS FACILITY IS SIMPLEX. CONTRACTOR EXISTING FIRE ALARM SYSTEM FOR THIS FACILITY IS SIMPLEX. CONTRACTOR TO WORK WITH SIMPLEX 4100 SYSTEMS FOR CONNECTIONS TO EXISTING FIRE ALARM SYSTEM. 3. EXISTING DEVICES SHALL BE RETAINED TO THE GREATEST EXTENT POSSIBLE EXISTING DEVICES SHALL BE RETAINED TO THE GREATEST EXTENT POSSIBLE UNLESS OTHERWISE NOTED. 4. THE CONTRACTOR SHALL REPROGRAM, TEST AND CERTIFY FIRE ALARM THE CONTRACTOR SHALL REPROGRAM, TEST AND CERTIFY FIRE ALARM SYSTEM AFTER NEW ELEVATOR SHUNT TRIP AND CONTROLS HAVE BEEN RE-CONNECTED. 5. ALL CABLING AND TIE-INS TO FIRE ALARM SYSTEM SHALL BE INSTALLED ALL CABLING AND TIE-INS TO FIRE ALARM SYSTEM SHALL BE INSTALLED BY CONTRACTOR. 6. FIRE ALARMS SHALL MEET THE REQUIREMENTS OF NFPA 72.FIRE ALARMS SHALL MEET THE REQUIREMENTS OF NFPA 72.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text N

AutoCAD SHX Text

AutoCAD SHX Text PROVIDE FIRE ALARMS IN THIRD FLOOR LOBBY ATTACH ALL FIRE ALARM WIRING PERTAINING TO ALL CONNECT ALL NEW ELEVATORS SYSTEMS TO THE EXISTING HOSPITAL MAIN FIRE ALARM SYSTEM & PANELS. INCLUDING SMOKE & FIRE ALARMS, AUXILIARY FIRE ALARM SYSTEMS & PANEL. CONTRACTOR TO PROVIDE NEW POINTS, CONNECTIONS, SOFTWARE AND HARDWARE FOR A COMPLETE SYSTEM PER NFPA.

AutoCAD SHX Text

AutoCAD SHX Text

M001

Elevator:

PO Box 464

Phone: 608.616.2999 Mequon, WI 53092

UPGRADE EAGLE AND FREIGHT

ELEVATORS

Email: AdamS@pec-wi.com POC: Aslam Husain

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

35% Schematic Design 10.15.2021 5.27.22

Project Number

Building Number

607-21-155

POC: Adam Smith

65% Construction Documents 12.29.2021 95% Construction Documents 3.18.2022 100% Construction Documents 5.27.2022

JSDS

AutoCAD SHX Text

1. CONTRACTOR IS RESPONSIBLE FOR TAKE-OFF QUANTITIES. ITEMS THAT ARE CONTRACTOR IS RESPONSIBLE FOR TAKE-OFF QUANTITIES. ITEMS THAT ARE REQUIRED FOR A COMPLETE INSTALLATION, BUT NOT SHOWN ON THE DRAWINGS OR INDICATED ON THE SPECIFICATIONS SHALL BE PROVIDED BY THE INSTALLATION CONTRACTOR TO ENSURE A SATISFACTORY OPERATING SYSTEM. 2. CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN MATERIAL QUOTES AND CONFIRM CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN MATERIAL QUOTES AND CONFIRM COMPLIANCE WITH SPECIFICATIONS AND DRAWINGS AND TO ENSURE COMPATIBILITY AND FUNCTIONALITY WITH THE SYSTEM PRIOR TO PROCUREMENT. 3. THE DRAWINGS ARE PREPARED WITH FEATURES SPECIFIC TO A PARTICULAR MODEL THE DRAWINGS ARE PREPARED WITH FEATURES SPECIFIC TO A PARTICULAR MODEL OF EQUIPMENT. FOR CHANGES IN THE VENDOR OR EQUIPMENT, THE INSTALLATION CONTRACTOR IS RESPONSIBLE FOR ALL CONSEQUENTIAL ENGINEERING AND CONSTRUCTION WORK FOR PROPER INSTALLATION AND OPERATION. 4. THE DRAWINGS DO NOT PRESENT FULLY DETAILED ASPECTS OF THE EXISTING THE DRAWINGS DO NOT PRESENT FULLY DETAILED ASPECTS OF THE EXISTING PHYSICAL CONDITIONS. THE INSTALLATION CONTRACTOR SHALL BE RESPONSIBLE TO VISUALLY IDENTIFY INTERFERENCES AND TO MAKE NECESSARY ADJUSTMENTS IN THE FIELD. 5. CONTRACTOR SHALL BE RESPONSIBLE TO IDENTIFY DISCREPANCIES AND BRING THEM CONTRACTOR SHALL BE RESPONSIBLE TO IDENTIFY DISCREPANCIES AND BRING THEM TO THE ATTENTION OF THE DEPARTMENT OF VETERANS AFFAIRS (V.A.) REPRESENTATIVES AS SOON AS POSSIBLE DURING BIDDING TO OBTAIN GUIDANCE. THIS SHALL NOT ALLEVIATE THE INSTALLATION CONTRACTOR OF THE RESPONSIBILITY TO PROVIDE A FULLY FUNCTIONING SYSTEM. 6. CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ALL APPLICABLE SPECIFICATIONS CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ALL APPLICABLE SPECIFICATIONS FROM THE PRIME CONTRACTOR. 7. CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN INSTRUCTIONS FROM THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN INSTRUCTIONS FROM THE DEPARTMENT OF VETERANS AFFAIRS REPRESENTATIVES FOR SPECIAL WORKING CONDITIONS SUCH AS ALLOWABLE WORK PERIODS, RESTRICTIONS ON TOOL USAGE, AND INSTALLATION PROCEDURES. 8. CONTRACTOR SHALL PROVIDE A FULLY FUNCTIONAL SYSTEM FOR THIS CONTRACT. CONTRACTOR SHALL PROVIDE A FULLY FUNCTIONAL SYSTEM FOR THIS CONTRACT. THE CONTRACT DRAWINGS AND SPECIFICATIONS ARE INDICATIVE OF OVERALL CAPACITY AND PERFORMANCE OF THE SYSTEM. ADDITIONAL COMPONENTS AND EQUIPMENT, FOR A FULLY FUNCTIONAL SYSTEM, MAY BE REQUIRED PER MANUFACTURER'S RECOMMENDED INSTALLATION GUIDELINES. ALL SUCH RECOMMENDED COMPONENTS AND EQUIPMENT ARE CONSIDERED AS PART OF CONTRACT REQUIREMENT. 9. ALL INTERIOR AND EXTERIOR WALL PENETRATIONS SHALL BE IMMEDIATELY ALL INTERIOR AND EXTERIOR WALL PENETRATIONS SHALL BE IMMEDIATELY PATCHED/REPAIRED AND PROPERLY FIRE SEALED WHERE APPLICABLE AFTER DUCTWORK/PIPING/CONDUIT IS REMOVED. 10. ALL ITEMS SHOWN ON THE DRAWINGS TO BE DEMOLISHED SHALL BE TAKEN OFF ALL ITEMS SHOWN ON THE DRAWINGS TO BE DEMOLISHED SHALL BE TAKEN OFF SITE FOR DISPOSAL BY CONTRACTOR UNLESS INDICATED OTHERWISE. 11.

This is the start of the file's text. The full file is on GovTribe.