S02 - JNA for Fire Alarm Components.pdf
PDF 317 KB Posted
- Attached to
- Z1DA--Replace Fire Sprinkler System Risers Bldg. 111 Project 695-19-104 Federal contract opportunity
- Solicitation number
- 36C25221B0021
About this file
This document contains a justification for a single source award and notice of a federal contract opportunity. The justification is for fire alarm components from Siemens Cerberus Pyrotronics required for a project to replace fire sprinkler risers at the Clement J. Zablocki VA Medical Center in Milwaukee, WI. The estimated cost of the Siemens components is $100,000. A single source is justified as these components must integrate with the existing campus-wide Siemens Cerberus Pyrotronics fire alarm system to ensure patient and worker safety.
The related federal contract opportunity is a pre-solicitation notice for Project 695-19-104 to replace the fire sprinkler risers at the Zablocki VA Medical Center with a period of performance of 660 calendar days. The project value is between $1-2 million. The solicitation will be posted to beta.sam.gov on July 8, 2021 with a bid opening on August 10, 2021. A pre-bid conference will be held. The opportunity is set aside as 100% for Service Disabled Veteran Owned Small Businesses.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25221B0021 0005.docx | DOCX document | |
| 695-19-104 Amend 05 Drawings.pdf | ||
| 695-19-104 Amend 05 Spec 01 01 10SN.pdf | ||
| 695-19-104 Amend 05 Spec 01 35 26 Safety Requirements.pdf | ||
| 695-19-104 Amend 05 Spec 00 01 10 TOC.pdf | ||
| 36C25221B0021 0004.docx | DOCX document | |
| S06 - Pre-Bid Walkthru Roster 07.20.21.pdf | ||
| 36C25221B0021 0003.docx | DOCX document | |
| S02 - Combined Riser PDF Attachment.pdf | ||
| S02 - Haz Material Report Attachment.pdf | ||
| S02 - Pre-Bid Walkthru Roster.pdf | ||
| 36C25221B0021 0002.docx | DOCX document | |
| S02 - Project Specifications updated 7 7 21.pdf | ||
| 36C25221B0021 0001.docx | DOCX document | |
| 36C25221B0021_1.pdf | ||
| S02 - DB Wage Determination.pdf | ||
| S02 - JNA for Hilti Firestop.pdf | ||
| S02 - Drawings.pdf | ||
| 36C25221B0021_1.docx | DOCX document | |
| S02 - Project Specifications.pdf |
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHAPM Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT
VHAPM Part 813.106 Page 1 of 2 Original Date: 08/30/17 Revision 02 Eff Date: 03/31/2020
DEPARTMENT OF VETERANS AFFAIRS
Justification for Single Source Awards IAW FAR 13.106-1 For
Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K)
Acquisition Plan Action ID:__36C252-21-AP-3280_____
1. Contracting Activity:
Department of Veterans Affairs, VISN 12, Zablocki Medical Center NCO 12 Construction Team 695-21-4-6985-0038
2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount:
This product, Siemens Cerberus Pyrotronics System, is the only product that allows for a single fire alarm system to be used throughout the Milwaukee facility. VA Milwaukee currently has the Cerberus Pyrotronics System as the campus-wide fire alarm system. The new alarm system(s) for this project 695-19-104 Replace Fire Sprinkler Risers Bldg. 111 will need to work with the rest of the system.
The estimated expected cost for Siemens Cerberus Pyrotronics System material is $100,000.
3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:
The fire alarm system will activate alarms within the building to alert occupants that assistance may be required. Installation of a system that interfaces properly with the existing system will ensure patient safety is maintained at the highest level. Additionally, installation of components that match the existing fire alarm system minimizes maintenance costs and bench stock requirements. No other system will integrate with our existing fire protection system. It is necessary to match the existing system to ensure there are no interface problems and that system operation and maintenance is maintained to ensure patient and worker safety.
https://www.acquisition.gov/?q=/browse/far/13
VHAPM Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT
VHAPM Part 813.106 Page 2 of 2 Original Date: 08/30/17 Revision 02 Eff Date: 03/31/2020
4. Description of market research conducted and results or statement why it was not conducted:
We have not been able to identify any other system that offers a seamless integration with our existing system.
5. Contracting Officer's Certification: Purchase is approved in accordance with FAR13.106-
1(b). I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.
Ryan McMillin Contracting Officer https://acquisition.gov/far/current/html/Subpart%2013_1.html#wp1125466 https://acquisition.gov/far/current/html/Subpart%2013_1.html#wp1125466
| 2021-07-06T13:56:09-0500 | |
| Ryan J Mcmillin 694313 |
File details come from the government source that posted it. Updated .