S02 - Drawings Part 2.pdf
PDF 19 MB Posted
- Attached to
- Z1DA--695-22-107 Replace Building 5 AHUs Federal contract opportunity
- Solicitation number
- 36C25223B0010
About this file
This document contains details of a federal solicitation and related technical file. The solicitation number 36C25223B0010 is for replacing air handling units in Building 5 at the Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12 facility. The technical file S02 - Drawings Part 2.pdf provides supplementary drawings for the project, which involves replacing existing air handling units to service Building 5. Responses to the solicitation are due on or before the unspecified date. The solicitation is for a firm-fixed-price contract to supply the necessary labor, materials, equipment, and supervision to remove and replace the building's air handling units.
View the file
Other files for this federal contract opportunity
Show all 30
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MECHANICAL
ROOM
OPEN OFFICES
WORKERS
COMP
OFFICE
CONFERENCE
COPY
RM
OFFICE
5-2-002
IT
UNISEX
TLT
207A
UNISEX
TLT
207B
KITCH
204A
UP
ST-2-05
STAIR
ST-2-04
STAIR
ST-2-03
STAIR
PORCH
213 PORCH
ELEVATOR
2-01
ST-2-07
VESTIBULE
EMPLOYEE
BENEFITS
5-1-SH-01
SHAFT
ROOF
SLOPE
UP
UPDN
DN
DF
XFEB
"NO EXIT" SIGN
ON DOOR
CAPACITYCLR
EXIT
33" 165
CAPACITYCLR
EXIT
33" 165
TRAVEL DISTANCE: 83'-4"
TRAVEL DISTANCE: 88'-2"
T R
A V
E L D
IS
T
XFEB
R
S
T U
V
XFEB
W
X
EVACUATION
PLAN
Q PB
1 2 3 4
A
C
EXIT ACCESS TRAVEL
(per NFPA 101, TABLE 39.26.2)
# OF MEANS OF
EGREES REQUIRED
(per NFPA 101, CHAPTER 7)
300'-00" MAXIMUM DISTANCE
(W/SPRINKLERED)
2 REQUIRED
OCCUPANT LOAD
(per NFPA 101, TABLE 7.3.1.2)
OCC. 3 = 5,184 GSF/150 = 35 PPL
OCC. 2 = 5,488 GSF/150 = 37 PPL
OCC. 1 = 5,608 GSF/150 = 38 PPL
OCC. B = 5,353 GSF/150 = 36 PPL
TOTAL OCCUPANCY = 146 PPL
GROSS BUILDING AREA
(OUTSIDE FACE WALLS)
LEVEL 3 - 5,184 SF
LEVEL 1 - 5,608 SF
REQUIRED # OF EXITS
(per NFPA 101, CHAPTER 7)
2 EXITS REQUIRED IF UNDER
49 TOTAL OCCUPANTS
# OF MEANS OF
EGRESS PROVIDED
2 MEANS OF EGRESS (EXISTING)
EGRESS INFORMATION
LEVEL 2 - 5,488 SF
BASEMENT - 5,353 SF
EXITS / EGRESS
ENCLOSURE (per NFPA
101, TABLE 7.1.3.2)
1 HR RATED ENCLOSURE
(EXISTING)
2 HR RATED ENCLOSURE
(EXISTING)
- 3 FLOORS OR FEWER
- 4 FLOORS
EGRESS PATH
EGRESS IDENTIFICATION
EXISTING FIRE EXTINGUISHER BRACKET
EXISTING FIRE EXTINGUISHER CABINET
EXISTING FDC
EXISTING AED CABINET
CONTROLLED ACCESS - ALWAYS
UNLOCKED IN DIRECTION OF EGRESS
EXIT SIGN
PHOTO REFERENCE - LETTER AND
DIRECTION
CA
XFEB
XFEC
FDC
XAED
CAPACITYCLR
EXTERIOR
EXIT
XX" ###
EXIT
IDENTIFICATION
EGRESS CLEAR
WIDTH
EGRESS
CAPACITY
K
ACCNT
ACCNT OFFICE
ACCNT MGR
OFFICE 308
KITCHEN
OFFICE
BUDGET OFFICE
OPEN OFFICE
302AEC
ELEC
CONFERENCE
DEPUTY
FINANCIAL MGR
OFFICE
MGMT ANALYST
OFFICE
OFFICE
IT
TLT
STAIR
3-04
STAIR
3-03
STAIR
3-05
3-01
ELEVATOR
PORCH
ROOF
SLOPE
ROOF
SLOPE
DF
DN
DN
XFEB
"NOT AN EXIT"
SIGN ON DOOR
CAPACITYCLR
EXIT
33" 165
CAPACITYCLR
EXIT
33" 165
TRAVEL DISTANCE: 102'-0"
TRAVEL DISTANCE: 88'-7"
BB
CC/NN
HH
JJ
XFEB
GG
EVACUATION PLAN
"NOT AN EXIT" SIGN ON
DOOR. DOOR ALSO
BOARDED ON THE
EXTERIOR AND BLOCKED
WITH A BAR ON THE
INTERIOR SIDE.
LL
EXISTING
GUARDRAIL
XFEB
OO
EVACUATION
PLAN
MM
XFEB
EVACUATION
PLAN
II
B
1 2 3 4
A
C
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/2 /2
:5
:0
P M
C U s e rs
\d c o rd o n \D o c u m e n ts \R e v it l o c a l\ A
-3
M ilw a u k e e B
A
H U
R e p la c e m e n t_ d c o rd o n a c g
-p a
.c o m
.r v t
LS102
SECOND AND THIRD FLOOR LIFE
SAFETY PLANS
4 5DGC
REPLACE BUILDING 5 AHUS
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 NOVEMBER 23, 2022
100% CONSTRUCTION DOCUMENTS
695-22-10721-319-Q30
B5
HD
PROPOSED USE:
OWNED BY: FEDERAL GOVERNMENT
CODE ENFORCEMENT JURISDICTION: FEDERAL
APPLICABLE CODES:
GENERAL CODE INFORMATION:
RENOVATION (EXISTING BUILDING)
CONSTRUCTION TYPE:
PRIMARY OCCUPANCY:
PROJECT NAME:
PROJECT ADDRESS:
OWNER OR AGENT:
SPRINKLERED
2021 ENERGY CONSERVATION CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL FIRE CODE
OFFICE
2HH (PER NFPA 101)
BUSINESS
2020 NFPA 70 NATIONAL ELECTRIC CODE
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN CODE
2021 NFPA 101 LIFE SAFETY CODE
2017 PG 18-13 VA BARRIER FREE DESIGN STANDARDS
REPLACE BUILDING 5 AHUS
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295
CLEMENT J. ZABLOCKI VAMC
CODE INFORMATION
NORTH
0 4 8 16
Scale: 1/8" = 1'-0"
EXISTING CONDITIONS - SECOND FLOOR LIFE SAFETY PLAN
LIFE SAFETY LEGEND
Scale: 1/8" = 1'-0"
EXISTING CONDITIONS - THIRD FLOOR LIFE SAFETY PLAN
NORTH
0 4 8 16
N
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
SECOND FLOOR
THIRD FLOOR
P Q R
S T U
V W X
Y Z (LS101 - RM. ST-03) AA
BB CC (LS101 - RM. 117) DD (LS101 - RM. 5-1-CR-01)
THE INFORMATION CONTAINED IN THESE DRAWINGS
ARE NOT A VERIFIED LIFE SAFETY SURVEY NOR ARE
THEY TO BE USED AS OFFICIAL DOCUMENTATION IN
THE LIFE SAFETY NARRATIVE OF BUILDING 5.
A NON-DESTRUCTIVE VISUAL OBSERVATION OF
BUILDING 5 WAS PERFORMED ON 7/72022. THE
PHOTOGRAPHS ON THE LIFE SAFETY DRAWINGS ARE
THE BASIS FOR DESIGN ASSUMPTIONS CONTAINED
WITHIN THE DOCUMENT DRAWINGS.
WALL RATINGS SHOWN IN THESE PLANS ARE TO
SERVE AS THE BASIS OF DESIGN FOR ANY
REPLACEMENT, PATCHWORK OR PENETRATIONS FOR
FIRE RATED CONSTRUCTION REQUIRED TO
ADEQUATELY PERFORM THE SCOPE OF WORK.
EXISTING WALL RATINGS HAVE NOT BEEN VERIFIED.
WE NOTE THE PROBABLE LOCATIONS OF FIRE RATED
CONSTRUCTION BASED UPON PHOTOGRAPHS OF THE
EXISTING CONDITIONS. THE WALL RATINGS FOR
STAIRS AND SHAFTS DESIGNATE THE REQUIRED 2HR
RATING IN COMPLIANCE WITH NFPA 101, 2021 EDITION.
CONTRACTOR IS TO REPLACE, REPAIR, PATCH, AND
INSTALL PENETRATIONS IN ACCORDANCE WITH THE
FIRE RATED CONSTRUCTION DESIGNATED ON THESE
PLANS.
NO EVACUATION PLANS SHOWING EGRESS AND EXIT
FROM THE BUILDING WERE PRESENT ON THE WALLS
OF THE BUILDING 5.
PATHS OF TRAVEL ARE INTENDED TO FOLLOW THE
EXISTING EGRESS SIGNS AND SHOULD NOT BE
MODIFIED UNLESS IT IS REQUIRED TO DO SO DURING
CONSTRUCTION IN ORDER TO COMPLETE THE SCOPE
OF WORK.
CONTRACTOR IS TO NOTIFY THE COR AND ARCHITECT
IF ANY EXISTING EGRESS LIGHTS ARE REQUIRED TO
BE TEMPORARILY DISABLED DURING CONSTRUCTION.
TEMPORARY MODIFICATIONS TO THE PATH OF TRAVEL
ARE TO BE COMMUNICATED TO AND COORDINATED
WITH THE COR AND ARCHITECT.
ALL LIFE SAFETY CONDITIONS TEMPORARILY MODIFIED
DURING CONSTRUCTION WILL REVERT TO THEIR
ORIGINAL CONDITION ONCE THE WORK HAS BEEN
COMPLETED.
A SEPARATE PATH FOR REMOVAL OF CONSTRUCTION
WASTE WILL BE COORDINATED WITH THE COR AND
NOTATED ON LS103.
A SEPARATE PATH FOR THE REMOVAL OF ASBESTOS
AND OTHER HAZARDOUS MATERIALS WILL BE
COORDINATED WITH THE COR AND NOTATED ON
LS103.
FIG. 1 BELOW IS THE EMERGENCY PLAN USED
THROUGHOUT THE BUILDING. IT DOES NOT MEET
CURRENT LIFE SAFETY STANDARDS. PHOTO SHOWS
EXISTING CONDITIONS AND NOT TO BE TAKEN AS
CURRENT OR CORRECT EVACUATION PLAN.
FIG. 1 EXISTING EVACUATION PLAN
DocuSign Envelope ID: C7A11FCE-2DC0-4945-ADC2-185C2F86D091
11/22/2022
DN
UP
DN
DN
EXIT ACCESS TRAVEL
(per NFPA 101, TABLE 39.26.2)
# OF MEANS OF
EGREES REQUIRED
(per NFPA 101, CHAPTER 7)
300'-00" MAXIMUM DISTANCE
(W/SPRINKLERED)
2 REQUIRED
OCCUPANT LOAD
(per NFPA 101, TABLE 7.3.1.2)
OCC. 3 = 5,184 GSF/150 = 35 PPL
OCC. 2 = 5,488 GSF/150 = 37 PPL
OCC. 1 = 5,608 GSF/150 = 38 PPL
OCC. B = 5,353 GSF/150 = 36 PPL
TOTAL OCCUPANCY = 146 PPL
GROSS BUILDING AREA
(OUTSIDE FACE WALLS)
LEVEL 3 - 5,184 SF
LEVEL 1 - 5,608 SF
REQUIRED # OF EXITS
(per NFPA 101, CHAPTER 7)
2 EXITS REQUIRED IF UNDER
49 TOTAL OCCUPANTS
# OF MEANS OF
EGRESS PROVIDED
2 MEANS OF EGRESS (EXISTING)
EGRESS INFORMATION
LEVEL 2 - 5,488 SF
BASEMENT - 5,353 SF
EXITS / EGRESS
ENCLOSURE (per NFPA
101, TABLE 7.1.3.2)
1 HR RATED ENCLOSURE
(EXISTING)
2 HR RATED ENCLOSURE
(EXISTING)
- 3 FLOORS OR FEWER
- 4 FLOORS
EGRESS PATH
EGRESS IDENTIFICATION
EXISTING FIRE EXTINGUISHER BRACKET
EXISTING FIRE EXTINGUISHER CABINET
EXISTING FDC
EXISTING AED CABINET
CONTROLLED ACCESS - ALWAYS
UNLOCKED IN DIRECTION OF EGRESS
EXIT SIGN
PHOTO REFERENCE - LETTER AND
DIRECTION
CA
XFEB
XFEC
FDC
XAED
CAPACITYCLR
EXTERIOR
EXIT
XX" ###
EXIT
IDENTIFICATION
EGRESS CLEAR
WIDTH
EGRESS
CAPACITY
K
B06HC
HAC
B11
CORRIDOR
B04
AIR
COMPRESSOR/STORAGE
B14
EQUIP AND
POWER
B13EC
ELEC
B12
CORRIDOR
B08
PAYROLL
STORAGE
B10
ELEV LOBBY
B07
STORAGE
B13
ELEVATOR
EQUIP
B01
STORAGE
B02
COPY ROOM
(RICOH)
STAIR
B-04
STAIR
B-03
UP
P
IP
E T
U N
N E
L
TO TUNNEL
B-01
ELEVATOR
B03
DISTRIBUTION
D N
DN
WALKWAY
STAIRS
FDC
TEMPORARY
AHU LOCATION
ELECT. PANEL
FOR POWER
TO TEMP. AHU
TEMP.
TRANSF.
TEMP. PWR. TO GO
THRU EXIST WINDOW
UP
UPDN WALKWAY
LOADING
DOCK
MECHANICAL YARD
EXISTING TREE
CANOPY OUTLINE
LANDSCAPING
LANDSCAPING
EVACUATION PLAN
LANDSCAPING
EXISTING TREE
CANOPY OUTLINE
A-002
EXISTING HANDRAIL
EXISTING
BLDG. 7
EXISTING
PARKING
SPACE
TEMP. PWR. TO GO
THRU EXIST WALL
EXISTING TREE
CANOPY OUTLINE
B
1 2 3 4
A
C
MECHANICAL
ROOM 112
OFFICE
5-1-SH-01
SHAFT
OFFICE
STORAGE
109EC
ELEC
5-1-001
VESTIBULE
OFFICE
5-1-012
ELEV LOBBY
5-1-006
JAN
5-1-CR-01
CORRIDOR
5-1-010
RECEPTION
OFFICE
CONFERENCE
OFFICE
OFFICE
IT
5-1-CR-02
CORRIDOR
KITCHEN
OFFICE
5-1-007
TLT
CLOSET
CL
5-1-004
OFFICE
CL106
CL
ENTRY
UP
STAIR
ST-04
STAIR
ST-03
ST-05
STAIR
5-1-009
TOILET
5-1-EL-01
ELEV CAB
5-1-002
TOILET
DN
DN
DN
DN
UP
UPDN
DN DN
DN
T R
A V
E L D
IS
T
A N
C E
TRAVEL DISTANCE: 65'-9"
T R
A V
E L D
IS
T
A N
C E
XFEC
XAED
XFEB
B
1 2 3 4
A
C
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/2 /2
:1
:2
A M
A
-3
M ilw a u k e e B
A
H U
R e p la c e m e n t_ d e ta c h e d .r v t
LS103
TEMPORARY CONSTRUCTION LIFE
SAFETY PLANS
5 5DGC
REPLACE BUILDING 5 AHUS
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 NOVEMBER 23, 2022
100% CONSTRUCTION DOCUMENTS
695-22-10721-319-Q30
B5
HD
PROPOSED USE:
OWNED BY: FEDERAL GOVERNMENT
CODE ENFORCEMENT JURISDICTION: FEDERAL
APPLICABLE CODES:
GENERAL CODE INFORMATION:
RENOVATION (EXISTING BUILDING)
CONSTRUCTION TYPE:
PRIMARY OCCUPANCY:
PROJECT NAME:
PROJECT ADDRESS:
OWNER OR AGENT:
SPRINKLERED
2021 ENERGY CONSERVATION CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL FIRE CODE
OFFICE
2HH (PER NFPA 101)
BUSINESS
2020 NFPA 70 NATIONAL ELECTRIC CODE
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN CODE
2021 NFPA 101 LIFE SAFETY CODE
2017 PG 18-13 VA BARRIER FREE DESIGN STANDARDS
REPLACE BUILDING 5 AHUS
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295
CLEMENT J. ZABLOCKI VAMC
CODE INFORMATION
LIFE SAFETY LEGEND
Scale: 1/8" = 1'-0"
TEMPORARY CONDITIONS - BASEMENT FLOOR LIFE SAFETY PLAN
Scale: 1/8" = 1'-0"
TEMPORARY CONDITIONS - FIRST FLOOR LIFE SAFETY PLAN
NORTH
0 4 8 16
NORTH
0 4 8 16
N
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
BASEMENT
FIRST FLOOR
EE (LS101 - RM. 101) FF GG
HH II JJ
KK LL MM
NN OO PP
DocuSign Envelope ID: C7A11FCE-2DC0-4945-ADC2-185C2F86D091
11/22/2022
File details come from the government source that posted it. Updated .