RFI Form 506-20-209.docx
DOCX document 16 KB Posted
- Attached to
- J041--506-20-209 Replace Air Handler Bldg 31 - 1 and 2 Federal contract opportunity
- Solicitation number
- 36C25020B0055
About this file
This document provides details for a federal contract opportunity with the Department of Veterans Affairs to replace air handlers at the Ann Arbor VA Medical Center in Ann Arbor, Michigan. The solicitation number is 36C25020B0055 and involves project number 506-20-209. The contract type will be firm fixed price with an estimated value between $500,000 and $1,000,000. The work includes removing and replacing internal components in two air handling units, including cooling coils, heating coils, humidifiers, fans, dampers and filters. Additional repairs such as casing rust remediation are also required. All components will be converted to direct digital controls. The contract duration is estimated at 120 days. Questions are due by the specified date in the solicitation and bids will be accepted via beta.SAM.gov on or around June 30th, 2020.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25020B0055 0004.docx | DOCX document | |
| Covid Instructions.docx | DOCX document | |
| Sign In Sheet 506-20-209.pdf | ||
| 03 G002.pdf | ||
| 48 - MH100 - BASEMENT HVAC PLAN.pdf | ||
| 36 A103.pdf | ||
| 36C25020B0055 0002.docx | DOCX document | |
| 47 - M001 - GENERAL MECHANICAL INFORMATION.pdf | ||
| 48 - MH103 - MECHANICAL HVAC PENTHOUSE PLAN.pdf | ||
| 36 A320.pdf | ||
| 01 G001.pdf | ||
| 36C25020B0055 0003.docx | DOCX document | |
| 506-20-209 AHU - Specifications.pdf | ||
| 506-20-209 - VA AA AHU Replacement - Bid Drawings.pdf | ||
| WD- ML20200100 07-24-2020.pdf | ||
| Contractor EMR Certification Form 2020.docx | DOCX document | |
| 36C25020B0055_1.docx | DOCX document |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR INFORMATION (RFI)
36C25020B0055
| PROJECT NUMBER: |
| 506-20-209 |
| Please ensure that before submitting questions or requests for clarification that you thoroughly read the solicitation, specifications, drawings and other pertinent documents. When submitting questions on this project the Government requires contractors to specifically identify the specification and/or solicitation section(s) or drawing number(s) in reference to the question or request for clarification submitted. No question or request for clarification will be answered by the Government unless the above requirements are met. Failure to comply may prevent the Government from responding in a timely manner. |
| PROJECT TITLE: |
| Replace Air Handler |
| PROJECT LOCATION: |
| Department of Veterans Affairs |
Ann Arbor VAMC 2215 Fuller Rd Ann Arbor, MI 48105
SUBMITTED BY:
City/State:
PHONE NO.:
TO:
Reginald Williams, Contract Specialist Department of Veterans Affairs 6150 Oak Tree Blvd, Suite 300.
Independence Ohio 44131 Reginald.williams2@va.gov
| RFI NO.: |
| DATE: |
| SPEC/DWG. REFERENCE: |
REPLY NEEDED BY:
INFORMATION NEEDED:
REPLY:
REPLY FROM:
DATE:
ATTACHMENTS:
COPY TO: