Brook Haven Requirements
Option CFGB
GSA options required:
DAOH
K32, 3 each
K37, 2 each
K41
K49
PLV
SG
STA
CPT
K04
K06F
K07S
K31
K34F
K34R
Additional Requirements
Relocate (1) curbside O2 Outlet to ceiling above chest arear of stretcher
Streetside rear compartment D to be 3/4 height with single door and two adjustable shelves.
Cabinets J, K, L2 are to flip up for restocking.
CPT comment - to be drip rail down white, white cab roof and A/B pillars, red to be FLNA 3042
Add inside directional notification above rear door.
JA-17-7000
Add access to cabinet B 2 from inside patient compartment. CSR-299085 - 336002
Install Zico O2 lift in compartment F for H clyinder
Install custom lettering per attached layout, install customer supplied door decals
White reflective belt in lieu of orange belt, belt to have approx. 1" white reflective belts above and below per layout dwg.
Rear chevrons to be full coverage including perforate on windows. Use 3M Diamond Grade material ILOS
(1) additional 110VAC outlet on wall 2 below K, approx. centered next to 12VDC (6K-40-2000)
(2) 12V power outlet (1) on wall 2 below cabinet K, approx. centered and (1) curbside wall panel near head of S/B. (6A-22-2500)
Comment - K32 ( 3 additional needed) (2) are stabdard, need locations all additional coax's. (1) in the A/A, (2) in center console.
Comment - K37 ( 2 additional needed) (2) are standard. Need locations on additional 12VDC pwr leads. .
Bio Hazard and sharps container at head of squad bench on pull out drawer.
Add commercial body 3170C with centered rear doors, OEM rear LED tail lights. Biohazard and sharps through A/A, glove box over curbside entry door, retain aluminum roll up door on bulkhead I/O cabinet.
Add lower window to curbside door (3P-10-8100) 336002
Glove box holder, interior, above curbside door
(TN-20-1001)
Cabinet L1 to be angled, delete net at head of CPR side seat. Add locking lever latch on L1.
Healthguard cabinet on walkthrough side of right front bulkhead cabinet (TU-12-2010)
Base wall cabinet to have inside outside access to compartment D through rear of base wall cabinet.
With sliding plexi window. See CA101224 for reference on this option only.
Add gray upholstery in patient compartment in lieu of standard
Add brushed stainless steel kick plates on face of base wall cabinet and face of squad bench
Change upper rear streetside red warning light to blue
Add anti microbial treatment to patient compartment