NDI Floor Drain Demo Plan.pdf

PDF 4 MB Posted

Attached to
B316 HVAC Repair Federal contract opportunity
Solicitation number
W50S8U-20-B-0002
Issued by
Department of the Army National Guard

About this file

This solicitation is for the replacement of an HVAC system and installation of a new floor drain in building 316 at a National Guard facility. The scope of work includes demolishing the existing HVAC equipment except for a new chiller, chilled water pumps, and associated piping. All HVAC controls will be replaced with an Automated Logic Controls system. Electrical components to the HVAC systems will also be replaced. A new 4-inch drain line will be installed from the non-destructive inspection area to connect to the main sewer line adjacent to Falcon Avenue. The existing concrete will be demolished partially in the width of existing panels and in 4'x4' holes for interior access. All work must be completed in accordance with the drawings and specifications provided in the solicitation from the Department of the Army National Guard.

View the file

Other files for this federal contract opportunity

Other files attached to B316 HVAC Repair, newest first.
File Type Posted
Sealed Bid OF 1419A B316 HVAC.pdf PDF
Bid Opening Sign In Sheet 9Sep20_Redacted.pdf PDF
Sealed Bid OF 1419 B316 HVAC.pdf PDF
Pre-Bid RFI 316 HVAC Project 09-01-2020.pdf PDF
Bid Bond Checklist Sealed Bid.pdf PDF
Compliance Checklist Sealed Bids.pdf PDF
B316 Site Visit Minutes.pdf PDF
B316 Site Visit Sign In Redacted.pdf PDF
Site Visit Slides 316 HVAC.ppt PPT presentation
138FW Safety Accident Prevention Guide_2018.pdf PDF
B316 XHZG182005 - Spec Manual.pdf PDF
SOW 1.07 316 HVAC Repair 2020.pdf PDF
EMS Commitment Statement.docx DOCX document
W50S8U-20-B-0002.pdf PDF
Bldg 316 Interior Drains.pdf PDF
316 HVAC AF 66 modified 1.2.pdf PDF
Brand Name 316 HVAC JA 1.4_Redacted.pdf PDF
NDI floor drain plan.pdf PDF
B316 XHZG182005 - Drawings.pdf PDF
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1/11/2019 Google Maps https://www.google.com/maps/@36.2169743,-95.8752087,92m/data=!3m1!1e3 1/2

316 NDI Floor Drain

1541174164M Line

1541174164M Rectangle

1541174164M Rectangle

1541174164M Rectangle

1541174164M Callout Existing sanitary sewer main to be connect to with new 4" drain line

1541174164M Rectangle

1541174164M Rectangle

1541174164M Callout Demolish concrete 1/2 width of existing panel size and 4'x4' holes in interior of the building for access

1/11/2019 Google Maps https://www.google.com/maps/@36.2169743,-95.8752087,92m/data=!3m1!1e3 2/2

Map data ©2019 Google 20 ft

File details come from the government source that posted it. Updated .