316 HVAC AF 66 modified 1.2.pdf
PDF 161 KB Posted
- Attached to
- B316 HVAC Repair Federal contract opportunity
- Solicitation number
- W50S8U-20-B-0002
- Issued by
- Department of the Army National Guard
About this file
This submittal schedule and federal contract opportunity document outlines requirements for an HVAC repair project at Building 316 on an Army National Guard base. The project includes replacing the existing HVAC and HVAC controls systems, running a new floor drain, and demolishing and replacing all electrical components to the systems. Bidders must provide product data, shop drawings, samples, warranties and other submittals as detailed in the submittal schedule. The federal contract opportunity is solicitation number W50S8U-20-B-0002 for the B316 HVAC Repair project. The project will replace the HVAC equipment, controls, and electrical components to update the systems. Automated Logic Controls systems are required as the brand name per the justification. The response due date is not provided. The Department of the Army National Guard is the contracting agency.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sealed Bid OF 1419A B316 HVAC.pdf | ||
| Sealed Bid OF 1419 B316 HVAC.pdf | ||
| Bid Opening Sign In Sheet 9Sep20_Redacted.pdf | ||
| Pre-Bid RFI 316 HVAC Project 09-01-2020.pdf | ||
| Bid Bond Checklist Sealed Bid.pdf | ||
| Compliance Checklist Sealed Bids.pdf | ||
| B316 Site Visit Minutes.pdf | ||
| Site Visit Slides 316 HVAC.ppt | PPT presentation | |
| B316 Site Visit Sign In Redacted.pdf | ||
| 138FW Safety Accident Prevention Guide_2018.pdf | ||
| B316 XHZG182005 - Spec Manual.pdf | ||
| NDI Floor Drain Demo Plan.pdf | ||
| B316 XHZG182005 - Drawings.pdf | ||
| W50S8U-20-B-0002.pdf | ||
| Bldg 316 Interior Drains.pdf | ||
| Brand Name 316 HVAC JA 1.4_Redacted.pdf | ||
| NDI floor drain plan.pdf | ||
| SOW 1.07 316 HVAC Repair 2020.pdf | ||
| EMS Commitment Statement.docx | DOCX document |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT NO.
XHZG182005
APPROVED DISAPPROVED
01.00.00 Submittal Schedule - AF Form 66
01.00.00
Transfer and Acceptance of DOD Real
Property - DD Form 1354
01.00.00
Contractor Hazardous Material Identification -
01.00.00
Solid Waste Recycling and Disposal
Reporting Form
01.00.10 Affirmative Procurement Reporting Form
01.00.00 DD Form 1354
01.32.00 Construction Schedule
01.32.33 Construction Photos
01.35.23 Safety Documentation as stated
01.40.00 Schedule of Test and Inspections
01.40.00 Permits, Licenses and Certificates
01.40.00 Quality Control Plan
01.74.00 Warranties
01.75.00
Starting System -Testing, Adjusting &
Balancing Reports
15 01.78.23 O & M Data
16 01.78.39 Project Record Documents
17 01.79.00 Instructional Training Program is applicable
23.01.30.52
Existing HVAC Air Distribution System
Cleaning
Product Data
18 23.05.13
Common Motor Requirements for HVAC
Equipment
Product Data
23.05.17 Sleeves and Sleeve Seal for HVAC Piping
19 Product Data for General Duty Valves
20 23.05.18 Escutcheons for HVAC Piping
21 Product Data
22 23.05.19 Meters and Gages for HVAC Piping
Product Data for Meters and Gages
Spec Section
C E
R T
IF
IC
A T
IO
N
O F
C
M P
L
IA
N C
E A
N D
C L O
S E
O U
T
SOLICITATION/CONTRACT NO.PROJECT TITLE
REPAIR BUILD 316 HVAC W5OS8U-20-B-0002
SCHEDULE OF MATERIAL SUBMITTALS
(AF Form 66 Modified)
NO. OF COPIES REQUIRED
TO BE COMPLETED BY PROJECT ENGINEER
O P
E R
A T
IN
G
I N
S T
R U
C T
IO
N
S
C A
T A
L O
G D
A T
A
L
IN
E N
U M
B E
R
M A
N U
F A
C T
U R
E R
'S W
A R
R A
N T
Y
O T
H E
R
M
A T
E R
IA
L o r
D A
T A
S H
O P
D R
A W
IN
G
S
S A
M P
L E
S
C O
L O
R S
E L E
C T
IO
N
M A
N U
F A
C T
U R
E R
'S
E
C O
M M
E N
D A
T
IO
N S
REMARKS
FINAL
APPROVAL
CONTRACTOR
RESUBMITTAL
RETURN
SUSPENSION
DATE
ITEM OR DESCRIPTION OF ITEM,
CONTRACT REFERENCE, TYPE OF
SUBMITTAL
FOLLOW-UP
SUBMITTAL
REQUIRED
BY 14 DAYS
AFTER
NTP
DATE
RECEIVED
IN
CONTRACTING
DATE
TO
CIVIL
ENGINEERING
DATE CONTRACTOR NOTIFIED
VXHZG182005
APPROVED DISAPPROVED
Spec Section
C E
R T
IF
IC
A T
IO
N
M P
L
IA
N C
E A
N D
C L O
S E
O U
T
SOLICITATION/CONTRACT NO.PROJECT TITLE
REPAIR BUILD 316 HVAC W5OS8U-20-B-0002
SCHEDULE OF MATERIAL SUBMITTALS
(AF Form 66 Modified)
NO. OF COPIES REQUIRED
TO BE COMPLETED BY PROJECT ENGINEER
O P
E R
A T
IN
G
I N
S T
R U
C T
IO
N
S
C A
T A
L O
G D
A T
A
L
IN
E N
U M
B E
R
M A
N U
F A
C T
U R
E R
'S W
A R
R A
N T
Y
O T
H E
R
M
A T
E R
IA
L o r
D A
T A
S H
O P
D R
A W
IN
G
S
S A
M P
L E
S
C O
L O
R S
E L E
C T
IO
N
M A
N U
F A
C T
U R
E
C O
M M
E N
D A
T
IO
N S
REMARKS
FINAL
APPROVAL
CONTRACTOR
RESUBMITTAL
RETURN
SUSPENSION
DATE
ITEM OR DESCRIPTION OF ITEM,
CONTRACT REFERENCE, TYPE OF
SUBMITTAL
FOLLOW-UP
SUBMITTAL
REQUIRED
BY 14 DAYS
AFTER
NTP
DATE
RECEIVED
IN
CONTRACTING
DATE
TO
CIVIL
ENGINEERING
DATE CONTRACTOR NOTIFIED
Shop Drawing
O & M Data
Warranty
23 23.05.23 General-Duty Valves for HVAC Piping
Product Data for General Duty Valves
24 22.05.29
Hangers & Supports for HVAC Piping &
Equipment
Product Data
Shop Drawing
O & M Data
Warranty
23.05.53
Identifcation for HVAC Piping and
Equipment
Product Data
Sample for ID
Equipment Label Schedule / Scheme
Valve Schedule
26 23.05.93 Testing, Adjusting, & Balancing for HVAC
Qualification Data
Contract Document Examination Report
Certified TAB Reports
26 23.07.13 Duct Insulation
Product Data on Duct Insulation
Samples of Insulation
27 23.07.19 HVAC Piping Insulation
Product Data on Insulation
Samples of Insulation
28 23.09.00 Instrumentation & Control for HVAC
Product Data on DDC System & Controls
Shop Drawing
Data Comm. Protocol Certificates
29 23.09.23.11 Control Valves
Product Data
Shop Drawing
O & M Data
Warranty
30 23.09.23.12 Control Dampers
Product Data
Shop Drawing
O & M Data
Warranty
31 23.09.93.11 Sequence of Operation for HVAC DDC
Control Sequences
32 23.11.23 Facility Natural Gas Piping
APPROVED DISAPPROVED
Spec Section
C E
R T
IF
IC
A T
IO
N
M P
L
IA
N C
E A
N D
C L O
S E
O U
T
SOLICITATION/CONTRACT NO.PROJECT TITLE
REPAIR BUILD 316 HVAC W5OS8U-20-B-0002
SCHEDULE OF MATERIAL SUBMITTALS
(AF Form 66 Modified)
NO. OF COPIES REQUIRED
TO BE COMPLETED BY PROJECT ENGINEER
O P
E R
A T
IN
G
I N
S T
R U
C T
IO
N
S
C A
T A
L O
G D
A T
A
L
IN
E N
U M
B E
R
M A
N U
F A
C T
U R
E R
'S W
A R
R A
N T
Y
O T
H E
R
M
A T
E R
IA
L o r
D A
T A
S H
O P
D R
A W
IN
G
S
S A
M P
L E
S
C O
L O
R S
E L E
C T
IO
N
M A
N U
F A
C T
U R
E
C O
M M
E N
D A
T
IO
N S
REMARKS
FINAL
APPROVAL
CONTRACTOR
RESUBMITTAL
RETURN
SUSPENSION
DATE
ITEM OR DESCRIPTION OF ITEM,
CONTRACT REFERENCE, TYPE OF
SUBMITTAL
FOLLOW-UP
SUBMITTAL
REQUIRED
BY 14 DAYS
AFTER
NTP
DATE
RECEIVED
IN
CONTRACTING
DATE
TO
CIVIL
ENGINEERING
DATE CONTRACTOR NOTIFIED
Product Data
Shop Drawing
Piping Schedule and Specialties
Service Meters
33 23.21.13 Hydronic Piping
Product Data on the following Material:
Air Control Devices
Hydronic Specialties
O & M Data
34 23.21.16 Hydronic Piping Specialities
Product Data
Shop Drawing
Warranty
O & M Data
35 23.21.23 Hydronic Pumps
Product Data
Shop Drawing
Warranty
O & M Data
36 23.23.00 Refrigerant Piping
Product Data
Piping Schedule
Piping Specialties
O & M Data
37 23.25.13
Water Treatment for Closed-Loop
Hydronic Systems
Product Data
Shop Drawing
Warranty
O & M Data
38 23.31.13 Metal Ducts
Product Data on the following material:
Sealants and Gaskets
Seismic Restraint Devices
Shop Drawings
39 23.33.00 Air Duct Accessories
Product Data
Shop Drawings for Duct Accessories
O & M Data
40 23.34.16 Centrifugal HVAC Fans
Product Data
Shop Drawing
Warranty
O & M Data
APPROVED DISAPPROVED
Spec Section
C E
R T
IF
IC
A T
IO
N
M P
L
IA
N C
E A
N D
C L O
S E
O U
T
SOLICITATION/CONTRACT NO.PROJECT TITLE
REPAIR BUILD 316 HVAC W5OS8U-20-B-0002
SCHEDULE OF MATERIAL SUBMITTALS
(AF Form 66 Modified)
NO. OF COPIES REQUIRED
TO BE COMPLETED BY PROJECT ENGINEER
O P
E R
A T
IN
G
I N
S T
R U
C T
IO
N
S
C A
T A
L O
G D
A T
A
L
IN
E N
U M
B E
R
M A
N U
F A
C T
U R
E R
'S W
A R
R A
N T
Y
O T
H E
R
M
A T
E R
IA
L o r
D A
T A
S H
O P
D R
A W
IN
G
S
S A
M P
L E
S
C O
L O
R S
E L E
C T
IO
N
M A
N U
F A
C T
U R
E
C O
M M
E N
D A
T
IO
N S
REMARKS
FINAL
APPROVAL
CONTRACTOR
RESUBMITTAL
RETURN
SUSPENSION
DATE
ITEM OR DESCRIPTION OF ITEM,
CONTRACT REFERENCE, TYPE OF
SUBMITTAL
FOLLOW-UP
SUBMITTAL
REQUIRED
BY 14 DAYS
AFTER
NTP
DATE
RECEIVED
IN
CONTRACTING
DATE
TO
CIVIL
ENGINEERING
DATE CONTRACTOR NOTIFIED
41 23.34.23 HVAC Power Ventilators
Product Data on items indicated
O & M Data
23.36.00 Air terminal Units
Product Data
Shop Drawing
Warranty
O & M Data
42 23.37.13 Diffusers, Registers, & Grilles
Product Data on the following material:
CD: Ceiling Diffusers
CG: Exhaust/Return Grille
43 23.52.16 Condensing Boilers
Product Data
Shop Drawing
Warranty
O & M Data
44 23.54.16.13 Gas-Fired Furnaces
Product Data
Shop Drawing
Warranty
O & M Data
45 23.55.23 Gas-Fired Radiant Heaters
Product Data
Shop Drawing
Warranty
O & M Data
46 23.62.00
Packaged Compressor and Condensing
Units
Product Data
Shop Drawing
Warranty
O & M Data
47 23.73.13
Modular Indoor Central-Station Air-
Handling Units
Product Data
Shop Drawing
Warranty
O & M Data
48 23.73.33.16
Indoor, Indirect-Fired Heating and
Ventilating Units
Product Data
Shop Drawing
Warranty
APPROVED DISAPPROVED
Spec Section
C E
R T
IF
IC
A T
IO
N
M P
L
IA
N C
E A
N D
C L O
S E
O U
T
SOLICITATION/CONTRACT NO.PROJECT TITLE
REPAIR BUILD 316 HVAC
SCHEDULE OF MATERIAL SUBMITTALS
(AF Form 66 Modified)
NO. OF COPIES REQUIRED
TO BE COMPLETED BY CONSTRUCTION AGENT
O P
E R
A T
IN
G
I N
S T
R U
C T
IO
N
S
C A
T A
L O
G D
A T
A
L
IN
E N
U M
B E
R
M A
N U
F A
C T
U R
E R
'S W
A R
R A
N T
Y
O T
H E
R
M
A T
E R
IA
L o r
D A
T A
S H
O P
D R
A W
IN
G
S
S A
M P
L E
S
C O
L O
R S
E L E
C T
IO
N
M A
N U
F A
C T
U R
E
C O
M M
E N
D A
T
IO
N S
REMARKS
FINAL
APPROVAL
CONTRACTOR
RESUBMITTAL
RETURN
SUSPENSION
DATE
ITEM OR DESCRIPTION OF ITEM,
CONTRACT REFERENCE, TYPE OF
SUBMITTAL
FOLLOW-UP
SUBMITTAL
REQUIRED
BY 14 DAYS
AFTER
NTP
DATE
RECEIVED
IN
CONTRACTING
DATE
TO
CIVIL
ENGINEERING
DATE CONTRACTOR NOTIFIED
49 23.74.16.11
Packaged, Small-Capacity, Rooftop Air-
Conditioning Units
Product Data
Shop Drawing
Warranty
O & M Data
50 23.81.13.13
Packaged Terminal Air-Conditioners, Outdoor, Wall-Mounted Units
Product Data
Shop Drawing
Warranty
O & M Data
51 23.81.23.13
Computer-Room Air-Conditioners, Ceiling-
Mounted Units
Product Data
Shop Drawing
Warranty
O & M Data
52 23.82.39.16 Propeller Unit Heaters
Product Data
Shop Drawings
O & M Data
Warranty
53 23.82.39.19 Wall and Ceiling Unit Heaters
Product Data
Shop Drawings
O & M Data
Warranty
54 26.05.19
Low-Voltage Electrical Power Conductors
& Cables
Product Data for Each Type of Cable
55 26.05.26
Grounding & Bonding for Electrical
Systems
O & M Data
56 26.05.33 Raceway & Boxes for Electrical Systems
Product Data on the following Material:
Metal Conduit & Tubing
Metal Wireways
Surface Raceways
Boxes, Enclosures, Cabinets
56 26.24.16 Panelboards
Product Data
Shop Drawings
O & M Data
Warranty
57 26.28.16 Enclosed Switches
W5OS8U-20-B-0002
APPROVED DISAPPROVED
Spec Section
C E
R T
IF
IC
A T
IO
N
M P
L
IA
N C
E A
N D
C L O
S E
O U
T
SOLICITATION/CONTRACT NO.PROJECT TITLE
REPAIR BUILD 316 HVAC W5OS8U-20-B-0002
SCHEDULE OF MATERIAL SUBMITTALS
(AF Form 66 Modified)
NO. OF COPIES REQUIRED
TO BE COMPLETED BY PROJECT ENGINEER
O P
E R
A T
IN
G
I N
S T
R U
C T
IO
N
S
C A
T A
L O
G D
A T
A
L
IN
E N
U M
B E
R
M A
N U
F A
C T
U R
E R
'S W
A R
R A
N T
Y
O T
H E
R
M
A T
E R
IA
L o r
D A
T A
S H
O P
D R
A W
IN
G
S
S A
M P
L E
S
C O
L O
R S
E L E
C T
IO
N
M A
N U
F A
C T
U R
E
C O
M M
E N
D A
T
IO
N S
REMARKS
FINAL
APPROVAL
CONTRACTOR
RESUBMITTAL
RETURN
SUSPENSION
DATE
ITEM OR DESCRIPTION OF ITEM,
CONTRACT REFERENCE, TYPE OF
SUBMITTAL
FOLLOW-UP
SUBMITTAL
REQUIRED
BY 14 DAYS
AFTER
NTP
DATE
RECEIVED
IN
CONTRACTING
DATE
TO
CIVIL
ENGINEERING
DATE CONTRACTOR NOTIFIED
Product Data
Shop Drawings
O & M Data
58 26.29.13 Enclosed Controllers
Product Data
Shop Drawings
| FRONT END |
| 000000 - Cover1 |
| 000000 - Table of Contents |
| 010000_I |
| 010000_Sup01 |
| Worksheets |
| Sheet1 |
| 010000_Sup02 - AF Form 66 revised 14Jan2016 |
| Worksheets |
| Page 1 |
| 010000_Sup02 - AF Form 66 revised 21April2017 |
| 010000_Sup03 |
| Worksheets |
| Page 1 |
| Page 2 |
| 010000_Sup04 |
| 010000_Sup05 |
| Worksheets |
| AF 3064 |
| 010000_Sup06 |
| Worksheets |
| Sheet1 |
| 010000_Sup08 |
| Worksheets |
| Sheet1 |
| 010000_Sup09 |
| Worksheets |
| Sheet1 |
| 010000_Sup10_013540_HVAC Upgrades |
| 010000_Sup11 - DD 1354 WORKSHEET_Jun 2013 |
| Worksheets |
| Sheet1 |
| 010000_Sup11 |
| 010000_Sup12 |
| Worksheets |
| Sheet1 |
| 010000_Sup13 |
| 010000_Sup14 |
| 010010_I |
| 010010_Sup01 |
| 010010_Sup02 |
| 010100_I |
| 011000_I |
| 012500 |
| 012600_Contract_Considerations |
| 012900_Applications_for_Payment |
| 013100_I |
| 013200_I |
| 013233_I |
| 013300_I |
| 013523_I |
| 014000_I |
| 014100_Project_Coordination |
| 014200_Reference_Standards |
| 014523_I |
| 015000_I |
| 015100_I |
| 015213_I |
| 015719_I |
| 016000_I |
| 016400_I |
| 017300_I |
| 017329_I |
| 017400_I |
| 017500_I |
| 017700_I |
| 017700_Sup01 |
| 017823_I |
| 017839_I |
| 017900_I |
| 018818_I |
| 65% Mech Specs |
| 230130.52 - EXISTING HVAC AIR DISTRIBUTION SYSTEM CLEANING |
| 230513 - COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT |
| 230517 - SLEEVES AND SLEEVE SEALS FOR HVAC PIPING |
| 230518 - ESCUTCHEONS FOR HVAC PIPING |
| 230519 - METERS AND GAGES FOR HVAC PIPING |
| 230523 - GENERAL DUTY-VALVES FOR HVAC PIPING |
| 230529 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT |
| 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT |
| 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC |
| 230713 - DUCT INSULATION |
| 230719 - HVAC PIPING INSULATION |
| 230800 - COMMISSIONING OF HVAC |
| 230900 - INSTRUMENTATION AND CONTROL FOR HVAC |
| 230923.11 - CONTROL VALVES |
| 230923.12 - CONTROL DAMPERS |
| 230993.11 - SEQUENCE OF OPERATIONS FOR HVAC DDC |
| 231123 - FACITLITY NATURAL-GAS PIPING |
| 232113 - HYDRONIC PIPING |
| 232116 - HYDRONIC PIPING SPECIALTIES |
| 232123 - HYDRONIC PUMPS |
| 232300 - REFRIGERANT PIPING |
| 232513 - WATER TREATMENT FOR CLOSED-LOOP HYDRONIC SYSTEMS |
| 233113 - METAL DUCTS |
| 233300 - AIR DUCT ACCESSORIES |
| 233416 - CENTRIFUGAL HVAC FANS |
| 233423 - HVAC POWER VENTILATORS |
| 233600 - Air Terminal Units |
| 233713 - DIFFUSERS, REGISTERS, AND GRILLES |
| 235113.16 - Vent Dampers |
| 235216 - CONDENSING BOILERS |
| 235416.13 - Gas-Fired Furnaces |
| 235513.16 - Gas-Fired Duct Heaters |
| 235523 - GAS-FIRED RADIANT HEATERS |
| 236200 - Packaged Compressor and Condenser Units |
| 237339 - Indoor, Direct-Fired Heating and Ventilating Units |
| 237416.11 - Packaged, Small-Capacity, Rooftop Air-Conditioning Units |
| 238113.13 - Packaged Terminal Air-Conditioners, Outdoor, Wall-Mounted Units |
| 238123.13 - Computer-Room Air-Conditioners, Ceiling-Mounted Units |
| 238239.16 - Propeller Unit Heaters |
| 238239.19 - Wall and Ceiling Unit Heaters |
| 65% ELEC SPECS |
| 260519 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES |
| 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS |
| 260529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS |
| 260533 - RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS |
| 260553 - IDENTIFICATION FOR ELECTRICAL SYSTEMS |
| 262416 - PANELBOARDS |
| 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS |
| 262913 - ENCLOSED CONTROLLERS |
File details come from the government source that posted it. Updated .