ITEM NO: 120-11-006
TITLE: Structural Repairs; accomplish
PARA. NO: 1.3.1 ; 3.1.1
PAGE NO: 1 and 2 of 4
ITEM NO: 251-31-004
TITLE: Engine Room Number 2; repair
PARA. NO: 3.2
PAGE NO: 1 of 2
ITEM NO: 251-31-004
TITLE: Engine Room Number 2; repair
PARA. NO: 3.4
PAGE NO: 1 of 2
ITEM NO: 251-31-004
TITLE: Engine Room Number 2; repair
PARA. NO: 3.3
PAGE NO: 1 of 2
ITEM NO: 583-11-001
TITLE: Boat Handling System; repair
PARA. NO: 3.4.11
PAGE NO: 2 of 4
ITEM NO: 644-11-002
TITLE: Shower Stall; repair
PARA. NO: 3.2
PAGE NO: 1 of 2
ITEM NO: 637-11-001
TITLE: Wardroom & Commanding Officers's
Cabin Ceiling Tile
PARA. NO:
PAGE NO:
REQUEST FOR SPECIFICATION CLARIFICATION
Attachment J-7
All new Government Responses are indicated in BOLD.
DATE OF REQUEST: 09/18/2015 SOLICITATION NO: N50054-15-R-0012
MARMC POC: Morgan Myrick
MARMC PHONE: 757-396-5041 x462 TITLE: USS FORREST SHERMAN (DDG-98) Dry-Docking Selected Restricted Availability (DSRA)
CONTRACTOR QUESTION 7: In the Solicitation page 31 it shows 637-
11-001 listed as the Forecastle Non-skid. Same item is also on the interactive index provided on the CD. However we received item 637-11-
001 Wardroom & Commanding Officer's Cabin Ceiling Tile; replace. Is
637-11-001 Wardroom & Commanding Officers's Cabin Ceiling Tile a good item?
GOVERNMENT RESPONSE:
Work Item 634-21-001 is for Forecastle Non-Skid; replace. Work Item
637-11-001 is for Wardroom and CO Cabin Ceiling Tile; replace. The title for Work Item 637-11-001 is incorrect on the Interactive Index but correct in the actual spec. Section C of the solicitation, CONTRACT
LINE ITEM NUMBER (CLIN) DESCRIPTIONS, has been updated to correct the title of work item 637-11-001.
GOVERNMENT RESPONSE:
NAVSEA Standard Items FY 16 will be used. Section C of the solicitation has been updated. Para 3.2 has been updated via ERRATA
Package #1 to reflect Table 3, Line 4, 5, 6, or 7. Line 5A was removed and Line 7 was added. To receive the ERRATA, please send an email request to Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract Specialist at
MARMC_NRFK_411_PROCUREMENT@navy.mil.
CONTRACTOR QUESTION 6:
Paragraph 3.2 calls out 009-32 table 3, line 5A, this line was last used in FY-
14. Should we be using FY-16 or FY-16 (CH-1)? Will this work item be updated?
CONTRACTOR QUESTION 5:
Paragraph 3.4.11 is to accomplish 009-32 to components disassembled in para 3.3. Paragraph 3.3 is the removal and disposal of oil and fluids. Please advise what is to be preserved.
GOVERNMENT RESPONSE:
Para 3.4.11 has been updated via ERRATA Package #1 to reflect para
3.4 in lieu of 3.3. To receive the ERRATA, please send an email request to Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract
Specialist at MARMC_NRFK_411_PROCUREMENT@navy.mil.
CONTRACTOR QUESTION 1: Paragraph
1.3.1 identifies IT101 as 8" x 10" x 10 pound as per reference 2.2 (100-
7060386). The drawing itself identifies IT101 as 8" x 4" x 10 pound.
Please clarify which is correct.
GOVERNMENT RESPONSE:
Para 1.3.1 has been updated via ERRATA Package #1 to reflect
8"x4"x10 pounds. To receive the ERRATA, please send an email request to Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract Specialist at
MARMC_NRFK_411_PROCUREMENT@navy.mil.
CONTRACTOR QUESTION 2:
Paragraph 3.2 is to surface prep bulkhead surfaces, resulting from the removals in 3.2.
There is no Paragragh in this Item for any repairs, what is the area to
Surface Prep?
GOVERNMENT RESPONSE:
Work Item has been modified via ERRATA package #2. To receive the ERRATA, please send an email request to Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract Specialist at
MARMC_NRFK_411_PROCUREMENT@navy.mil.
GOVERNMENT RESPONSE:
Work Item has been modified via ERRATA package #2. To receive the ERRATA, please send an email request to Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract Specialist at
MARMC_NRFK_411_PROCUREMENT@navy.mil.
CONTRACTOR QUESTION 3:
Paragraph 3.4 is to preserve surface areas prepaired in para 3.3. (this is an inspection paragraph) and based on a report submitted in 3.4.1. (No Para.
3.4.1 in the work item). What are the Repairs needed to be Preserved?
CONTRACTOR QUESTION 4:
Paragraph 3.3 states to inspect areas surface prep'ed in 3.3. Should this paragraph reference paragraph 3.2? What areas are being repaired in 3.2
(surface prep para) to inspect?
GOVERNMENT RESPONSE:
Work Item has been modified via ERRATA package #2. To receive the ERRATA, please send an email request to Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract Specialist at
MARMC_NRFK_411_PROCUREMENT@navy.mil.
ITEM NO: 042-51-001
TITLE: Condition Report Estimating
PARA. NO:
PAGE NO:
ITEM NO: 857-11-002 and 857-11-003
TITLE: Tech Library
PARA. NO:
PAGE NO:
ITEM NO: 123-11-001
TITLE: Fuel Oil Tank; Group 1
PARA. NO: 3.2.1
PAGE NO: 1
ITEM NO: 123-15-001
TITLE: Lube Oil
PARA. NO: 3.1
PAGE NO:
ITEM NO: 251-31-004
TITLE: Intake, Eng Rm NO 2
PARA. NO: 3.2, 3.4
PAGE NO:
ITEM NO: 495-90-001
TITLE: S/A 77279K & S/A 81798K
PARA. NO: 2.2
PAGE NO: 1
ITEM NO: 495-90-001
TITLE: SA 77279K CANES
PARA. NO: 2.12
PAGE NO: 1
ITEM NO: 514-80-001
TITLE: SA 76721D TOTS Valves
PARA. NO: 2.4
PAGE NO:1
CONTRACTOR QUESTION 14: Ref. 2.12 lists a 4720 Summary of
GFM, however the 4720 provided does not have this S/A listed. Please provide a list of GFM
GOVERNMENT RESPONSE:
An updated 4720 is provided by request via CD/DVD in Amendment
0001. To request a copy of the CD/DVD, please send an email request to Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract
Specialist at MARMC_NRFK_411_PROCUREMENT@navy.mil.
Offerors may pick up the CD/DVD at the MARMC Technical Library located at 9727 Avionics Loop, Bldg LF-18, Norfolk, VA 23511-2393.
Dale Camat Email: dale.camat@navy.mil Phone number: (757) 443-
3872 ext 2546 OR Christopher Beckelhimer Email:
chris.beckelhimer@navy.mil Phone number: (757) 443-3872 ext 1836.
CONTRACTOR QUESTION 15: Ref. 2.4 lists a 4720 Summary of GFM, however the 4720 provided does not have this S/A listed. Please provide a list of GFM
GOVERNMENT RESPONSE:
An updated 4720 is provided by request via CD/DVD in Amendment
0001. To request a copy of the CD/DVD, please send an email request to Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract
Specialist at MARMC_NRFK_411_PROCUREMENT@navy.mil.
Offerors may pick up the CD/DVD at the MARMC Technical Library located at 9727 Avionics Loop, Bldg LF-18, Norfolk, VA 23511-2393.
Dale Camat Email: dale.camat@navy.mil Phone number: (757) 443-
3872 ext 2546 OR Christopher Beckelhimer Email:
chris.beckelhimer@navy.mil Phone number: (757) 443-3872 ext 1836.
GOVERNMENT RESPONSE:
Work Item has been modified via ERRATA package #2. To receive the ERRATA, please send an email request to Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract Specialist at
MARMC_NRFK_411_PROCUREMENT@navy.mil.
CONTRACTOR QUESTION 13: Drawing 512-8670099 was saved under the file name "180-8670093." on the CD. We received 2 copies of 512-
8670099. Please provide a copy of Re. 2.2 180-8670093
GOVERNMENT RESPONSE:
Drawing 180-8670093 will be made available by request on a CD/DVD.
To request a copy of the CD/DVD, please send an email request to
Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract
Specialist at MARMC_NRFK_411_PROCUREMENT@navy.mil.
Offerors may pick up the CD/DVD at the MARMC Technical Library located at 9727 Avionics Loop, Bldg LF-18, Norfolk, VA 23511-2393.
Dale Camat Email: dale.camat@navy.mil Phone number: (757) 443-
3872 ext 2546 OR Christopher Beckelhimer Email:
chris.beckelhimer@navy.mil Phone number: (757) 443-3872 ext 1836.
CONTRACTOR QUESTION 12: Para 3.2 directs contractors to accomplish 009-32 for surfaces prepared on the bulkhead surfaces resulting from the removals in 3.2. Then in Para 3.4 it directs contractor to accomplish 009-32 for preservation of surfaces prepared in 3.3. There is no direction given as to what is to be surface preped and painted. Please provide some direction for preservation.
CONTRACTOR QUESTION 8: This item is written for a cost type job.
Item indicates the Contractor will develop grown specs. Since this is a
FFP contract, we recommend this item be deleted.
GOVERNMENT RESPONSE:
This work item has been cancelled via ERRATA Package #1.
GOVERNMENT RESPONSE:
These work specs were cancelled. Section C in the solicitation has been updated accordingly.
CONTRACTOR QUESTION 9: These two items are listed in the
Solicitation under Seciton C on page 31. They are not included in the package and are not on the interactive index provided on the disc. Since this is a FFP Contract, we assume these items are not included in the package.
CONTRACTOR QUESTION 10: This para states to remove and install new studs. Many of these studs are more than likely in good condition.
Typically the specification will state to renew a certain amount, not all.
Recommend changing para 3.2.1 to remove and renew 100 existing studs
GOVERNMENT RESPONSE:
Para 3.2.1 has been updated via ERRATA Package #1. To receive the
ERRATA, please send an email request to Reagan Criddle, Contracting
Officer, and Morgan Myrick, Contract Specialist at
MARMC_NRFK_411_PROCUREMENT@navy.mil.
CONTRACTOR QUESTION 11: This item tells contractor to on-load
12,000 gals of 2190-TEP. 1) Is the Government going to bring the Lube
Oil to the yard in their truck? 2) how does the Government want the contractors to on-load the Lube oil? Will the Goverment provide the hose and fittings to onload the Lube Oil
GOVERNMENT RESPONSE:
Para 3.1 has been updated via ERRATA Package #2 to reflect "Procure and on-load 12,000 gallons on 2190-TEP..." The contractor is to provide all the material and fittings as well. To receive the ERRATA, please send an email request to Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract Specialist at
MARMC_NRFK_411_PROCUREMENT@navy.mil.
ITEM NO: 588-90-001
TITLE: SA 82957K Stwg Mod for MH-60R
PARA. NO: 2.8
PAGE NO: 1
ITEM NO: 441-90-001
TITLE: SA 81443K Navy Multiband Termainal
PARA. NO: 5
PAGE NO: 4
ITEM NO: 437-21-002
TITLE: MRG Sump Tank Temp Gage; Replace
PARA. NO: 1.3.1
PAGE NO: 1
ITEM NO: 582-11-002
TITLE: RETRACTABLE CHOCK COVERS;
REPLACE
PARA. NO: 3.1, 3.2, 3.2.1.1, 3.3.1 AND
1.3.7
PAGE NO:
ITEM NO: 123-15-001
TITLE: Lube Oil; provide
PARA. NO: 3.1
PAGE NO: 1 of 1
ITEM NO: 123-11-006
TITLE: Uptake Engine Room No. 2 Manhole
Cover; preserve
PARA. NO: 3.3, 3.4
PAGE NO: 1 of 2
ITEM NO: 631-21-002
TITLE: SLQ-32 Maintenance Platform;
preserve
PARA. NO: 3
PAGE NO: 1 of 1
ITEM NO: 243-11-001
TITLE: Propulsion Shafting; inspect and repair
PARA. NO: 3.26
PAGE NO: 8 of 8
ITEM NO: 243-12-001
TITLE: Propulsion Shafting; inspect and repair
PARA. NO: 3.26
PAGE NO: 8 of 8
CONTRACTOR QUESTION 23:
FY-16 009-32 Table One, Line 8 is for dielectric shields. Para. 3.26 says to use this table and line for final shaft preservation. Should this reference be
Table One, Line 9?
GOVERNMENT RESPONSE:
Para 3.26 has been updated via ERRATA Package #2 to reflect Table
One, Line 9. To receive the ERRATA, please send an email request to
Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract
Specialist at MARMC_NRFK_411_PROCUREMENT@navy.mil.
CONTRACTOR QUESTION 24:
FY-16 009-32 Table One, Line 8 is for dielectric shields. Para. 3.26 says to use this table and line for final shaft preservation. Should this reference be
Table One, Line 9?
GOVERNMENT RESPONSE:
Para 3.26 has been updated via ERRATA Package #2 to reflect Table
One, Line 9. To receive the ERRATA, please send an email request to
Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract
Specialist at MARMC_NRFK_411_PROCUREMENT@navy.mil.
CONTRACTOR QUESTION 22:
Will the SLQ-32 be removed or staying in place?
GOVERNMENT RESPONSE:
SLQ-32 will be removed by Code 200 for refurbishment OT01-
0752/0754.
CONTRACTOR QUESTION 18: Para 1.3.1 calls out Find No. F00043 of reference 2.3 which is a thermowell, not a temperature gage. Please clarify if we are replacing the gage or the thermowell. If we are replacing the gage, there is not currently enough information to identify for procurement.
Please provide more information on the gage.
GOVERNMENT RESPONSE:
As mentioned in WN EM01-1116 block 35, the "FITTING" requires replacement.
GOVERNMENT RESPONSE:
An updated 4720 is provided by request via CD/DVD in Amendment
0001. To request a copy of the CD/DVD, please send an email request to Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract
Specialist at MARMC_NRFK_411_PROCUREMENT@navy.mil.
Offerors may pick up the CD/DVD at the MARMC Technical Library located at 9727 Avionics Loop, Bldg LF-18, Norfolk, VA 23511-2393.
Dale Camat Email: dale.camat@navy.mil Phone number: (757) 443-
3872 ext 2546 OR Christopher Beckelhimer Email:
chris.beckelhimer@navy.mil Phone number: (757) 443-3872 ext 1836.
CONTRACTOR QUESTION 16: Ref. 2.8 lists a 4720 Summary of GFM, however the 4720 provided does not have this S/A listed. Please provide a list of GFM
CONTRACTOR QUESTION 17: Para 5.1 states Kit for SA 81443K, but there is no list showing what this kit consists of. Please provide list of
Kitted Material.
GOVERNMENT RESPONSE:
No Kitted Material will be provided. The LMA will be ordering all IAF material on the FDN & PIPING drawings and the SPAWAR AIT will be ordering all IAF material on the block wiring diagram (BWD).
GOVERNMENT RESPONSE:
Work Item has been updated via ERRATA Package #3 to reflect the following: Deleted para 1.3.3. Changed para 3.2 to say 1.3.5 through
1.3.6. Changed para 3.2.1.1 to say 3.2.1 instead of 3.1.1. Changed para
3.3.1 to say 1.3.1 through 1.3.4. Deleted para 1.3.7. To receive the
ERRATA, please send an email request to Reagan Criddle, Contracting
Officer, and Morgan Myrick, Contract Specialist at
MARMC_NRFK_411_PROCUREMENT@navy.mil.
CONTRACTOR QUESTION 19: Para 3.1 calls out 1.3.1 through 1.3.4,
1.3.3 does not apply to hull # 98.
Para 3.2 calls out removal of 1.3.4 through 1.3.6, 1.3.4 is part of Chock
Cover Assemblies. Should it read 1.3.5 and 1.3.6?
Para 3.2.1.1 calls out 3.1.1. 3.1.1 is “Template exact size” for Chock Cover
Assemblies, should it read 3.2 vice 3.1.1?
3.3.1 Calls out 009-32 for equipment listed in 1.3.4, should this read 1.3.1 through 1.3.4.
1.3.7 Calls out “Quantity (5 EA) Retractable Chock Cover. No action is called out in specification to do any repairs.
CONTRACTOR QUESTION 21:
Please correct the coating system for the Uptakes. Paragraph 3.3 calls out
Table 4 Line 3 which is for Non-Aircraft carrier Potable Water tanks.
Paragraph 3.4 calls out Table 4, Line 11 which is for CHT/MSD Tanks.
Should we instead estimate using Table 3, Lines 17, 18 or 20?
GOVERNMENT RESPONSE:
Para 3.3 has been updated via ERRATA Package #2 to remove Table 4, Line 3 and incorporate Table 3, Line 20. To receive the ERRATA, please send an email request to Reagan Criddle, Contracting Officer, and Morgan Myrick, Contract Specialist at
MARMC_NRFK_411_PROCUREMENT@navy.mil.
CONTRACTOR QUESTION 20:
For 009-32 estimating purposes, please identify the locations and number of
"various sumps and storage tanks" that comprise the scope of this work item.
GOVERNMENT RESPONSE: The below list of locations for the various sumps and storage tank are for estimating purposes only: CPP
Hydraulic Oil Sump Tank (4-208-1-F)
CPP Hydraulic Oil Sump Tank (4-254-2-F)
Lube Oil Sump Tank (5-206-1-F)
Lube Oil Sump Tank (5-254-6-F)
3-174-1-F LUBE OIL STORAGE TANK
3-185-1-F LUBE OIL STORAGE TANK
3-195-1-F LUBE OIL STORAGE TANK
3-272-2-F LUBE OIL STORAGE TANK
3-281-2-F LUBE OIL STORAGE TANK
3-291-2-F LUBE OIL STORAGE TANK
ITEM NO: 152-11-001
TITLE: MK7 Lifeboat Brackets; replace
PARA. NO: 3 3
PAGE NO: 2
ITEM NO: 261-11-001
TITLE: NO 1B Fuel Oil Service Pump & Gear
Reducer
PARA. NO:
PAGE NO:
ITEM NO: 622-12-001
TITLE: False Deck Panels
PARA. NO: 3.1.4 & 3.1.5
PAGE NO:1
ITEM NO: 992-31-003
TITLE: Cleaning and pumping
PARA. NO: 3.3
PAGE NO: 4
ITEM NO: 514-80-001
TITLE: S/A 76721D
PARA. NO: 2.3
PAGE NO: 1
ITEM NO: 437-21-002
TITLE: MRG Sump Tank Temp Gage; Replace
PARA. NO: 1.3.1
PAGE NO: 1
ITEM NO: 514-21-001
TITLE: Air Conditioning Plant Condenser;
clean
PARA. NO: 3.3.2
PAGE NO: 1
ITEM NO: 562-11-003
TITLE: Rudder Stock Bearing; inspect
PARA. NO: 3.3
PAGE NO: 2
ITEM NO: 643-11-002
TITLE: TABLE TOP; REPLACE
PARA. NO: 1.3
PAGE NO: 1
ITEM NO: 520-11-001
TITLE: Sea Valves
PARA. NO: 3.6
PAGE NO: 2 of 10
ITEM NO: 631-11-002
TITLE: Auxiliary Mach Room NO. 1 Bilge;
pres
PARA. NO: 3.3, 3.3.1
PAGE NO:1
ITEM NO: 655-80-001
TITLE: SA 429D Self Service Laundry
PARA. NO: 2.18
PAGE NO:
CONTRACTOR QUESTION 32: There seem to be a conflict between the
Tech Manual S9562-AR-MMA-010 Rev 1 (2.2) and 562-7060062 Rev C
(2.4). The Tech Manual calls for 20 bolts 1-1/8"-7 steel carbon (item #4) under 5-2.2 Material List. But on 562-7060062 sheet #5 the 1-1/8"-7 bolt
(FN4) is K-MNL Gr. 500. Which is correct?
GOVERNMENT RESPONSE:
1-1/8"-7 bolt (FN4) is K-MNL Gr. 500, per ref 2.4 (DDG 80 AF)
CONTRACTOR QUESTION 33: The table tops listed on this work item do not specify material. The references listed don't show the identified table tops. Please provide more information for procurement.
GOVERNMENT RESPONSE:
Replace "formica" top and CRES edging and template from shipboard conditions, color and design as per direction of the
Supervisor.
GOVERNMENT RESPONSE:
The Temperature probe part number is 41GSY00GA20Y;
NIIN is 01-213-6225.
CONTRACTOR QUESTION 31: Para 3.3.2 calls for to repair up to 20 ea loose studs. There are (2) different stud lengths, 3-1/4" lg and 3" lg. The question is the 20 ea for each length or 20 ea total?
GOVERNMENT RESPONSE:
The amount of 20 each size will need to be ordered.
CONTRACTOR QUESTION 30: Para 1.3.1 calls out Find No. F00043 of reference 2.3 which is a thermowell, not a temperature gage. Please clarify if we are replacing the gage or the thermowell. If we are replacing the gage, there is not currently enough information to identify for procurement.
Please provide more information on the gage.
CONTRACTOR QUESTION 26: This item was provided in the CD
Package…..However, this item is not listed in Seciton C in the Solitation.
Is this item part of the package and if so please change Section C to include
GOVERNMENT RESPONSE:
Work Item 261-11-001 is included in the package and has been added to Section C CLIN Description.
GOVERNMENT RESPONSE:
Quantity of holes to weld and re-drill are provided using 2.3 for guidance.
CONTRACTOR QUESTION 27: Para 3.1.4 , 3.1.5 states to plug weld & redrill exitsting tapped holes in angle gridwork IWO deck panels removals.
For estimating purposes and so all are bidding on the same number, please provide a number of holes to be plugged and redrilled.
CONTRACTOR QUESTION 28: Para 3.4 states to Pump tanks containing petroleum products. For estimating purposes, please add the quantity of petrolium products and compensating water as was done on the USS James
E Williams item 992-31-001 errata 3.
GOVERNMENT RESPONSE:
The tanks will be pumped down to low suction levels per work spec
992-31-002, Off-load and Testing of Ship's Petroleum Feul and
Lubricant; accomplish.
CONTRACTOR QUESTION 29: RLAR 76721/DDG93/1119465, Sheet 6 asks to ADD Valves V0001 - V0004 but doesn't give whether they will be sourced as IAF or GFM. Please provide clarification.
GOVERNMENT RESPONSE:
Valves are to be provided GFM
CONTRACTOR QUESTION 25: Para 3.3 directs KTR to fabricate and install new top horizontal CRES brackets from 10 sf of SS316L plating listed in 1.3.2…based on report submitted and designated by supervisor.
The upper stowage bracket for DHLSW/BG016 is listed on sheet 7F of 2.3 and does not include 1/4" plate. Pieces 20 & 21 of sheet 7k are 1/4" plate, but belong to the cradle support assembly shown on DTL 7E-D sheet 7E of
7058789. Please provide sheet/details for what is to be replaced.
GOVERNMENT RESPONSE:
Wn did not specify piece DHLSW/BG016, Wn addressed steel, external horizontal life raft brackets, use material identified and template from ship.
CONTRACTOR QUESTION 35: Para 3.3 states "New fasteners for deck plate and grating shall conform to material specifications of 2.4 and 2.5.
For bidding purposes, how many new fasteners does the Government want replaced? In addition, para 3.3.1 states to weld build-up, drill and tap deck plates and deck supports. Please provide how many holes the Government wants repaired.
GOVERNMENT RESPONSE:
For Estimating Purposes only: 200 New Fasteners (retain existing as many can be reused if they need more) and 25 holes repaired.
CONTRACTOR QUESTION 36 This item shows kitted material and a
4720 identified in Ref. 2.18. There is nothing listed on the 4720 provided indicating kitted material for this item. Please provide a listing of GFM
GOVERNMENT RESPONSE:
All material is IAF. There is no GFM for this work spec.
CONTRACTOR QUESTION 34:
Spec para. 3.6, calls for new install of 2-1/2 and below valves IAW Ref.2.2, listed valves are provided as GFM IAW spec para.5.1-5.15. Are the GFM valves furnished with 500 Nickel Copper Aluminum Alloy (K Monel) fasteners as required IAW 3.6? Or is contractor to price fasteners IAW information provided? (Contractor recommends a visual inspection and report be added to spec to verify fasteners material).
GOVERNMENT RESPONSE:
The Sea Valves are GFM, but the 500 Nickel Copper Aluminum
Alloy (K Monel) fasteners are IAF. The MT discussed the BQ # 34 and we decided we did not need to add an inspection because all the bolts will be replaced with Monel K-500 bolts according to MIL-
STD-777 Para. 4.16 h(1) which states that all bolted hull integrity piping connections, being all flanged joints from the hull up to and including the inboard flange of the hull valve, shall be fitted with nickel-copper aluminum alloy fasteners (Monel K-500) in accordance with MIL-DTL-1222 and with self-locking nuts in accordance with MIL-DTL-32258.