Attachment 15 Questions and Answers 4.pdf
PDF 106 KB Posted
- Attached to
- Refurbishment of SBDC Federal contract opportunity
- Solicitation number
- N4523A20Q5710
About this file
This document contains a combined synopsis and solicitation for a federal contract opportunity to refurbish Shear Block Disposal Containers. The Naval Supply Systems Command within the Department of the Navy is seeking to refurbish 30 large and 11 small SBDC units under the first two production batches, with options for additional units. Offerors must be registered in SAM and provide representations and certifications. The period of performance is from February 28, 2020 through August 1, 2020 at the vendor's facility. The solicitation incorporates various FAR and DFARS clauses around security, SAM registration, payment, and requests for equitable adjustment.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 14 FAR 52.212-2 Evaluation - Commercial Items AMENDED.docx | DOCX document | |
| Attachment 13 Questions and Answers 3.pdf | ||
| Attachment 12 Questions and Answers 2.pdf | ||
| Attachment 10 Questions and Answers 1.pdf | ||
| Attachment 11 PWS SBDC Refurbishment Amended.pdf | ||
| Attachment 9 2301-3962_Small SBDC.pdf | ||
| Attachment 7 DWG 2301-3411 Rev F.pdf | ||
| Attachment 4 Full Text FAR 52.212-5.pdf | ||
| Attachment 3 Corporate Experience Data Sheet.doc | DOC document | |
| Attachment 5 CONTRACTOR_BADGING_AND_ACCESS_REQUIREMENTS_SOLICITATION.pdf | ||
| Attachment 2 FAR 52.212-2.pdf | ||
| Attachment 6 WD 2015-4075.pdf | ||
| Attachment 1 PWS SBDC Refurbishment.pdf | ||
| Attachment 8 2301-3961_Large-SBDC_Orig.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 15 Questions and Answers 4
1. Can the tapped holes in Pc-3 be through holes?
A: No. This application requires the holes in Pc. 3 to be drilled/tapped as shown in View D-18 of DWG
2301-3961 and DWG 2301-3962.
2. Pc-3 (inside corners) and Pc-2 (outside corners) show sharp corners. Can we radius them, and if so, what is the maximum?
A: The sharp edges shall be groomed to 1/32” chamfer (minimum) per General Note 3B of DWG 2301-
3961 and DWG 2301-3962. The Government would be agreeable to an approximately 1/8” chamfer. The edges are required to be groomed to prevent sharp edges from piercing or tearing plastic as stated in
General Note 7, as well as not being sharp enough to injure/cut personnel.