04--BID SCHEDULE (Draft for Contractor Estimate).docx

DOCX document 18 KB Posted

Attached to
Repair HVAC Federal contract opportunity
Solicitation number
M2638220MPT1860
Issued by
Department of the Air Force Reserve Command

About this file

This bid schedule and related federal contract opportunity notice outline requirements for replacing HVAC units at a Marine Reserve Facility in Westover Air Reserve Base, Massachusetts. The solicitation will be issued on May 26, 2020 through sealed bid procedures, with bid opening on July 7, 2020. The project scope involves removing and disposing of two existing roof top condensing units and associated piping and coils, and replacing them to support the new R-410A refrigerant. The contractor must provide all necessary labor, equipment, materials and supervision. The contract is a small business set-aside with a magnitude between $250,000 and $500,000. The performance period is 150 calendar days from notice to proceed. Interested parties must register in SAM and check the website for any amendments to the full solicitation, which will include specifications, drawings and wage rates.

View the file

Other files for this federal contract opportunity

Other files attached to Repair HVAC, newest first.
File Type Posted
Abstract of Offers KTR 7.8.2020.pdf PDF
Abstract of Offers KTR.pdf PDF
RFI 2 Before Award HVAC.pdf PDF
RFI Before Award HVAC.pdf PDF
SOW HVAC 4.6.20.docx DOCX document
Special Standards of Responsibility.pdf PDF
H.3.3.pdf PDF
15951a HVAC SOO.pdf PDF
H.1.2.pdf PDF
H.1.3.pdf PDF
Solicitation - FA660620B0004 Issued.pdf PDF
Wage Determinations 3.13.2020.pdf PDF
H.1.5.pdf PDF
H.1.1.pdf PDF
H.3.1.pdf PDF
Submittal Register - Final 1.31.2020.xls XLS spreadsheet
H.2.1.pdf PDF
Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REPAIR HVAC MARINE RESERVE CENTER, B3505 YTPM 19-0005

WESTOVER ARB - CHICOPEE, MA

BID SCHEDULE

Offeror’s Name:

ITEM# DESCRIPTION TOTAL

0001 Per Scope of Work and as described here:

The project consists of removal and disposal and replacement of existing roof top condensing units (CU-1) and (CU-2) and associated piping and cooling coil servicing AHU-1 and AHU-3 located on the second level mechanical room. The existing unit operates on R-22 refrigerant and will require new refrigerant piping and cooling coil located in AHU-1 and AHU-3. The new refrigerant piping and cooling coil will be sized and piped in accordance with manufacturer’s recommendations to support R-410A operating pressure and temperature. The contractor is responsible for all pipe supports and wall penetration seals required to support new piping. Once unit and associated piping have been installed test and balance AHU-1 and AHU-2 and associated VAV’s along with respective supply and return grills for proper CFM.

Lot $

TOTAL BASE BID $

AWARD: Only one award will be made as result of this solicitation and such award will be made in the aggregate to the low responsible and responsive bidder. Bidder must bid on all items. Failure to do so shall be cause for rejection of the bid.

NOTE: Although not specifically identified in items 0001 above, all items specified in Technical Provisions and shown on the Contract Drawings are incorporated in this schedule.

-- END OF BID SCHEDULE --

BID SCHEDULE – PAGE 1