LAL_Terminal_Hold_Room_Drawings.pdf
PDF 19 MB Posted
- Attached to
- Terminal Hold Room Expansion
- Solicitation number
- 2026-ITB-085
- Issued by
- Polk County, Florida
About this file
Terminal Hold Room Expansion Project Summary
This is a comprehensive set of architectural and engineering drawings and specifications for the Terminal Hold Room Expansion project at Lakeland Linder International Airport in Lakeland, Florida. The project involves the construction of a new modular building addition totaling approximately 5,370 square feet to expand passenger terminal capacity. The new facility will include a 3,958 square foot departure lounge, men's and women's restrooms (133 SF each), a family restroom (91 SF), a janitor closet (26 SF), a storage area (55 SF), a SARA (Special Assistance/Relief Area) room (85 SF), an electrical closet (52 SF), and associated corridors. The project is classified as Group A-3 (Assembly) occupancy with an occupant load of 303 persons and includes life safety systems, fire protection, and full mechanical, plumbing, and electrical systems. The construction timeline is divided into a 60-calendar-day mobilization phase followed by a 150-calendar-day construction phase, with total project duration of 210 calendar days. The modular building design utilizes delegated design principles, with the selected manufacturer responsible for final design, engineering, fabrication, and construction of all structural, architectural, mechanical, electrical, plumbing, fire protection, and accessibility components.
The project is subject to the 2023 Florida Building Code with Risk Category II classification and includes wind load design criteria for 150 MPH ultimate wind speed in a wind-borne debris region. The site is located at 3900 Don Emerson Drive in Lakeland and is not in a FEMA flood hazard area. Utility work includes new water service connections via 1.5-inch PVC lines and sanitary sewer connections through 4-inch SDR35 PVC laterals, with all work performed in coordination with City of Lakeland utilities. Site work encompasses concrete pavement installation, gravel base preparation, security fencing modifications including removal of existing fence and installation of new black vinyl chain-link fencing with controlled access gates, utility relocation including electrical and fiber optic systems, and landscape restoration using FDOT-specified sod. The contractor is required to obtain all permits, conduct geotechnical testing for foundation design, verify existing utility locations, maintain airport security protocols including AOA (Airport Operations Area) badging requirements, and provide detailed submittals including modular building shop drawings, calculations, and product approvals prior to fabrication and construction commencement.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATE MAP:
STATE OF FLORIDA
CITY OF LAKELAND
VICINITY MAP:
PROJECT
LOCATION
PROJECT No.:
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright Mead & Hunt, Inc.
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
4010 West Boy Scout Blvd, Suite 1000 Tampa, FL 33607 phone: 813-210-8740 meadhunt.com
HOLDROOM EXPANSION
3900 DON EMERSON DR, SUITE 210
LAKELAND, FL
4667719-261066.01
LAKELAND LINDER
INTERNATIONAL AIRPORT
L A
K E
L A
N D
L
IN
D E
R
IN
T E
R N
A T
IO
N
A L A
IR
P
O R
T
D O
N E
M E
R S
O N
D R
S
U
IT
E
L A
K E
L A
N D
F
L
H O
L D
R O
O M
E X
P A
N S
IO
N
G-001
COVER SHEET
NOT FOR CONSTRUCTION
4667719-261066.01
KB
AM
07/16/2026
MMR
GENERAL
G-001 COVER SHEET
G-003 GENERAL NOTES
G-004 CONTRACTOR LAYOUT AND PHASING PLAN
G-011 CODE ANALYSIS SCHEDULES
G-021 LIFE SAFETY AND OCCUPANCY PLANS
CIVIL
C-051 EXISTING CONDITION AND DEMOLITION
PLAN
C-121 PROPOSED SITE AND UTILITY PLAN
C-131 SITE DETAILS - SHEET 1
C-132 SITE DETAILS - SHEET 2
C-151 UTILITY DETAILS - SANITARY SEWER
C-152 UTILITY DETAILS - WATER
C-153 LIGHT POLE FOUNDATION DETAIL
ARCHITECTURAL
A-001 NOTES & SYMBOLS
A-101 FLOOR PLAN
A-111 ROOF PLAN
A-121 REFLECTED CEILING PLAN
A-201 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-401 TOILET ACCESSORIES
A-601 DOOR SCHEDULES /DETAILS
A-710 ARCHITECTURAL FINISH SCHEDULE
FIRE PROTECTION
F-001 SYMBOLS, ABBREVIATIONS, NOTES AND
DETAILS
F-002 SYMBOLS, ABBREVIATIONS, NOTES AND
DETAILS
F-101 FIRST FLOOR FIRE SPRINKLER PLAN
F-102 FIRST FLOOR FIRE ALARM PLAN
PLUMBING
P-001 NOTES, SYMBOLS, ABBREVIATIONS, AND
DETAILS
P-099 UNDERGROUND PLUMBING PLAN
P-101 FIRST FLOOR DRAIN AND VENT PLAN
P-131 FIRST FLOOR SUPPLY PLAN
P-401 ENLARGED PLANS
P-601 SCHEDULES
P-901 DRAIN AND VENT ISOMETRIC
P-931 SUPPLY ISOMETRIC
MECHANICAL
M-001 NOTES, SYMBOLS AND ABBREVIATIONS
M-101 FIRST FLOOR MECHANICAL PLAN
M-102 MECHANICAL ROOF PLAN
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
M-603 MECHANICAL SCHEDULES
SHEET INDEX
ELECTRICAL
E-001 NOTES, SYMBOLS & ABBREVIATIONS
E-100 ELECTRICAL SITE PLAN
E-101 FIRST FLOOR POWER PLAN
E-110 ROOF POWER PLAN
E-121 FIRST FLOOR LIGHTING PLAN
E-401 ENLARGED PLANS, ELEVATIONS &
SECTIONS
E-501 DETAILS
E-502 DETAILS
E-503 DETAILS
E-601 LIGHTING SCHEDULES
E-602 EQUIPMENT SCHEDULE
E-603 PANEL SCHEDULES
E-701 ONE-LINE DIAGRAM
TECHNOLOGY SYSTEMS
T-001 NOTES, SYMBOLS & ABBREVIATIONS
TD011 FIRST FLOOR SITE DEMOLITION PLAN
TD100 FIRST FLOOR DEMOLITION PLAN
T-011 FIRST FLOOR TECHNOLOGY SITE PLAN
T-100 FIRST FLOOR TECHNOLOGY PLAN -
OVERALL
T-101 FIRST FLOOR COMMUNICATIONS PLAN
T-121 FIRST FLOOR SECURITY PLAN
T-141 FIRST FLOOR AUDIO VISUAL PLAN
T-401 ENLARGED PLANS, ELEVATIONS &
SECTIONS
T-501 DETAILS
T-502 DETAILS
T-601 SCHEDULES
T-701 ONE-LINE DIAGRAMS
MODULAR BUILDING DELEGATED DESIGN
THESE CONTRACT DOCUMENTS ESTABLISH THE BASIS OF DESIGN, PERFORMANCE REQUIREMENTS, AND DESIGN INTENT FOR THE MODULAR BUILDING. FINAL DESIGN, ENGINEERING, FABRICATION, AND CONSTRUCTION OF THE MODULAR BUILDING SYSTEM, INCLUDING ALL STRUCTURAL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, ACCESSIBILITY, AND CODE COMPLIANCE REQUIREMENTS NECESSARY FOR A COMPLETE AND OPERABLE FACILITY, SHALL BE THE RESPONSIBILITY OF
THE SELECTED MODULAR BUILDING MANUFACTURER.
THE MANUFACTURER SHALL PROVIDE SIGNED AND SEALED SHOP DRAWINGS, CALCULATIONS, SPECIFICATIONS, PRODUCT APPROVALS, AND OTHER SUPPORTING DOCUMENTATION PREPARED BY DESIGN PROFESSIONALS LICENSED IN THE STATE OF
FLORIDA FOR ARCHITECT/ENGINEER REVIEW PRIOR TO FABRICATION AND PERMITTING.
THE MANUFACTURER SHALL BE RESPONSIBLE FOR COORDINATING AND VALIDATING ALL DIMENSIONS, CONNECTIONS, COMPONENTS, DELEGATED DESIGN ELEMENTS, AND SYSTEM INTEGRATION NECESSARY TO SATISFY THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND APPLICABLE CODES, REGULATIONS, AND AUTHORITIES HAVING JURISDICTION.
MODULAR BUILDING STRUCTURAL DESIGN CRITERIA
GOVERNING CODE: 2023 FLORIDA BUILDING CODE (FBC)
RISK CATEGORY: II
DEAD LOAD: BY MODULAR BUILDING MANUFACTURER
COLLATERAL DEAD LOAD: BY MODULAR BUILDING MANUFACTURER**
ROOF LIVE LOAD: 20 PSF
FLOOR LIVE LOAD: 100 PSF
ROOF SNOW LOAD: NOT APPLICABLE PER 2023 FBC SECTION 101.2
WIND LOADS:
SEISMIC LOADS: NOT APPLICABLE PER 2023 FBC SECTION 101.2
GEOTECHNICAL DESIGN DATA: TO BE DETERMINED BY FOUNDATION DESIGNER (DELEGATED DESIGN) AS THE STRUCTURE
IS A MODULAR SYSTEM AND WILL BEAR ON FLEXIBLE PAVEMENT.
FLOOD LOAD: STRUCTURE ISN’T LOCATED IN A FLOOD HAZARD AREA; THEREFORE, FLOOD DESIGN DATA IS NOT
REQUIRED
RAIN LOADS:
RAIN INTENSITY (100-YEAR):
PRIMARY DRAINAGE SYSTEM: I = 7.47 IN/HOUR (15-MIN DURATION)
SECONDARY DRAINAGE SYSTEM: I = 3.91 IN/HOUR (60-MIN DURATION)
**THE MODULAR BUILDING MANUFACTURER IS RESPONSIBLE FOR ACCOUNTING FOR ALL ANTICIPATED COLLATERAL DEAD LOADS THAT MAY BE SUPPORTED FROM EITHER THE ELEVATED FLOOR OR ROOF SYSTEM. THIS INCLUDES, BUT IS NOT LIMITED TO ARCHITECTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION (INCLUDING THE NFPA 250-LB HANGER LOAD), ELECTRICAL, AND
LIGHTING SYSTEMS.
***THE MODULAR BUILDING STRUCTURE IS IN A WIND-BORNE DEBRIS REGION. GLAZING SHALL BE PROTECTED WITH AN IMPACT RESISTANT COVERING OR GLAZING SHALL BE IMPACT RATED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE.
07/16/26 BID DOCUMENTS
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead and Hunt, Inc.
© Copyright 2026 Mead & Hunt, Inc.
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
4010 West Boy Scout Blvd, Suite 1000
Tampa, FL 33607 phone: 813-210-8740 meadhunt.com
LA
KE
LA
N
D L
IN
D
ER
IN
TE
R
N
AT
IO
N
AL
AI
R
PO
R T
D O
N E
M
ER
SO
N
D R
, S U
IT
E
LA
KE
LA
N
D , F
L
H O
LD
R
O O
M E
XP
AN
SI
O
N
07/16/26 BID DOCUMENTS
GENERAL NOTES
G-003
NOT FOR CONSTRUCTION
CPS
DSB
DES
W ed ne sd ay , J ul y
, 2
:4
8:
A M
X:
\4
\2
6.
\T
EC
H \C
AD
\C
AD
F ile s\
Sh ee ts \G en er al N ot es
.d w g
07/16/2026 4667718-261066.01
GENERAL NOTES:
1. PROJECT LOCATION: BASED ON THE FEMA FLOOD INSURANCE RATE MAP -COMMUNITY PANEL NUMBER 12105C0460G, EFFECTIVE DATE - DECEMBER 22, 2016, THE CONSTRUCTION AREA FOR THE
PROJECT IS IN ZONE X, AREAS OF MINIMAL FLOODING.
2. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL CONTACT CITY OF LAKELAND, FEDERAL AVIATION ADMINISTRATION, LOCAL UTILITY COMPANIES, AND SUNSHINE STATE ONE CALL CENTER OF FLORIDA TO IDENTIFY UNDERGROUND UTILITIES AND/OR CABLES WITHIN THE PROJECT LIMITS AND/OR STAGING AREA. SEE CONTACT TABLE BELOW FOR MORE INFORMATION.
3. THE LOCATION AND SIZE OF ALL EXISTING UTILITIES AND GROUND TOPOGRAPHIC FEATURES HAS BEEN PREPARED FROM FIELD SURVEYS AND AVAILABLE RECORDS. THIS INFORMATION IS NOT GUARANTEED. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ANY EXISTING UTILITIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL VERIFY ALL UTILITIES, BY ELECTRONIC AND MAGNETIC METHODS AND BY HAND EXCAVATION WHERE NECESSARY IN COORDINATION WITH CITY OF LAKELAND AND ALL UTILITY COMPANIES, PRIOR TO BEGINNING ANY CONSTRUCTION OPERATIONS. ALL UTILITIES ENCOUNTERED DURING CONSTRUCTION SHALL BE RECORDED AND SHOWN ON AS-BUILT PLANS.
4. ANY DAMAGE TO UTILITIES CAUSED BY THE CONTRACTOR (REGARDLESS OF WHETHER THEY WERE LOCATED OR NOT BY CITY OF LAKELAND, THE ENGINEER, ETC.) SHALL BE REPAIRED BY THE CONTRACTOR IN COORDINATION WITH THE AFFECTED UTILITY COMPANY TO THE SATISFACTION OF THE UTILITY COMPANY AND RPR. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR
THE COST OF THE REPAIRS AND ANY CONSEQUENTIAL DAMAGES.
5. THE CONTRACTOR SHALL DOCUMENT EXISTING CONDITIONS BY VIDEO OR OTHER MEANS APPROVED BY RPR WITHIN CONSTRUCTION WORK LIMITS AND SUBMIT A COPY TO THE RPR PRIOR TO
START OF ANY CONSTRUCTION ACTIVITIES.
6. EXISTING SECTION CORNERS AND OTHER LAND MARKERS OR MONUMENTS LOCATED WITHIN THE LIMITS OF CONSTRUCTION ARE TO BE PROTECTED AND MAINTAINED BY THE CONTRACTOR.
ANY MARKERS OR MONUMENTS DAMAGED BY CONSTRUCTION ACTIVITIES SHALL BE RESET AFTER CONSTRUCTION BY A REGISTERED LAND SURVEYOR IN ACCORDANCE WITH MINIMUM
TECHNICAL STANDARDS.
7. SOIL BORING DATA IS AVAILABLE AS ATTACHMENT WITHIN CONTRACT SPECIFICATIONS. DATA PROVIDED IS FOR THE CONTRACTOR'S INFORMATION ONLY. NEITHER THE OWNER NOR ENGINEER MAKE ANY REPRESENTATION REGARDING EXISTING SUBSOIL CONDITIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PERFORM ADDITIONAL SOIL BORINGS TO VERIFY THE LIMITS OF
UNSUITABLE MATERIAL ON-SITE.
8. ALL APPLICABLE PERMITS MUST BE OBTAINED BY THE CONTRACTOR PRIOR TO COMMENCEMENT OF CONSTRUCTION. A COPY OF ALL REQUIRED PERMITS SHALL BE KEPT ONSITE AT ALL TIMES.
9. ALL PAVEMENTS, GRASSED AREAS, DRAINAGE STRUCTURES, ETC. DISTURBED AS A RESULT OF THIS CONSTRUCTION EFFORT, IN A MANNER NOT CALLED FOR IN THE DRAWINGS, SHALL BE RESTORED TO ITS ORIGINAL CONDITION PRIOR TO THE COMPLETION OF THE PROJECT AT NO ADDITIONAL COST TO THE OWNER.
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OFFSITE DISPOSAL OF ALL ITEMS REMOVED WITHIN THE LIMITS OF CONSTRUCTION, INCLUDING UNSUITABLE AND EXCESS SOILS RESULTING FROM EARTHWORK OPERATIONS, UNLESS SPECIFICALLY REQUESTED IN WRITING TO REMAIN ON-SITE AS PROPERTY OF THE AIRPORT. THE COST ASSOCIATED WITH HAULING AND DISPOSAL OF THESE ITEMS SHALL BE AN INCIDENTAL TO THE CORRESPONDING BID ITEM. THE CONTRACTOR WILL BE RESPONSIBLE FOR DISPOSING OF THESE ITEMS IN ACCORDANCE WITH APPLICABLE
LAWS.
11. STOCKPILED MATERIAL AND OPEN EXCAVATIONS SHALL BE TREATED IN SUCH A MANNER TO PREVENT MOVEMENT RESULTING FROM AIRCRAFT JET BLAST OR WIND CONDITIONS UP TO 50 MPH.
OPEN TRENCHES AND STOCKPILED MATERIALS SHALL NOT BE PERMITTED WITHIN AN ACTIVE RUNWAY OR TAXIWAY OBJECT FREE AREA. ALL STOCKPILE LOCATIONS SHALL BE APPROVED BY THE RPR. THE AIRPORT OPERATOR MUST ENSURE THAT STOCKPILED MATERIALS AND EQUIPMENT ADJACENT TO THESE AREAS ARE PROMINENTLY MARKED WITH RED FLAGS AND LIGHTED DURING HOURS OF RESTRICTED VISIBILITY OR DARKNESS. THIS INCLUDES DETERMINING AND VERIFYING THAT MATERIALS ARE STORED AT AN APPROVED LOCATION TO PREVENT FOREIGN
OBJECT DAMAGE AND ATTRACTION OF WILDLIFE.
12. THE RPR SHALL HAVE THE AUTHORITY TO HALT CONSTRUCTION OPERATIONS AT ANY TIME, FOR ANY REASON. THE OWNER CAN REQUIRE THE CONTRACTOR TO LEAVE AIRPORT PROPERTY AND EVACUATE THE WORK AREA WITHIN THIRTY (30) MINUTES AFTER RECEIVING NOTICE. THE CONTRACTOR WILL NOT BE COMPENSATED FOR THE TEMPORARY SUSPENSION OF WORK.
13. ACCESS FOR AIRPORT OR LOCAL EMERGENCY PERSONNEL SHALL BE MAINTAINED AT ALL TIMES. EMERGENCY VEHICLES SHALL HAVE THE RIGHT-OF-WAY OVER ALL CONTRACTOR OPERATIONS.
CONTRACTOR'S MOT SHALL INCLUDE AN APPROVED EMERGENCY VEHICLE ROUTE.
14. THE CONTRACTOR IS RESPONSIBLE FOR THE IMMEDIATE CLEANUP OF ANY DEBRIS DEPOSITED ALONG ANY HAUL ROAD AS A RESULT OF THE CONSTRUCTION TRAFFIC.
15. DESIGN AND CONSTRUCTION OF PROJECT COMPLIES WITH 2023 FLORIDA BUILDING, MECHANICAL, PLUMBING, ACCESSIBILITY AND ENERGY CONSERVATION CODES AND THE 2020 NEC ELECTRICAL CODES. FLORIDA BUILDING CODES FBC.B 102.2 AND 105.3: BUILDING DESIGN CRITERIA
16. NO GEOTECHNICAL TESTING HAS BEEN COMPLETED BY THE ENGINEER. ANY GEOTECHNICAL TESTING REQUIRED FOR THE FINAL DESIGN OF THE MODULAR BUILDING AND ASSOCIATED
FOUNDATIONS/PLATFORMS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
SAFETY AND SECURITY NOTES:
1. THE CONTRACTOR SHALL COMPLY WITH ALL SECURITY REQUIREMENTS SPECIFIED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR
SHALL DESIGNATE IN WRITING TO THE RPR, THE NAME OF THE "CONTRACTOR SAFETY AND SECURITY OFFICER". THE CONTRACTOR SECURITY OFFICER SHALL REPRESENT THE CONTRACTOR ON THE SECURITY REQUIREMENTS OF THE CONTRACT IN ACCORDANCE WITH FAA ADVISORY CIRCULAR 150/5370-2G OPERATIONAL SAFETY ON AIRPORTS DURING CONSTRUCTION. THE CONTRACTOR'S SECURITY OFFICER SHALL PROVIDE THE RPR WITH 24-HOUR CONTACT INFORMATION FOR HIMSELF AND TWO ALTERNATES IN THE EVENT OF AN EMERGENCY DURING NON-WORKING HOURS. CONTRACTOR WILL BE WORKING ON AN ACTIVE AIRPORT WITH EXISTING SAFETY AND SECURITY REQUIREMENTS. CONTRACTOR SHALL REVIEW CONSTRUCTION SAFETY AND PHASING PLAN (CSPP), AND SHALL SUBMIT A SAFETY PLAN COMPLIANCE DOCUMENT (SPCD) TO THE OWNER PRIOR TO RECEIVING THE NOTICE TO PROCEED. THE SPCD SHALL COMPLY WITH THE
REQUIREMENTS OF FAA ADVISORY CIRCULAR AC 150/5370-2G.
2. THE CONTRACTOR SECURITY OFFICER SHALL BE RESPONSIBLE FOR BRIEFING ALL PERSONNEL ON SAFETY REQUIREMENTS AND, FROM TIME TO TIME, OTHER SECURITY PROVISIONS ADOPTED BY THE AIRPORT CONSTRUCTION SECURITY COMMITTEE. ALL NEW CONTRACTOR EMPLOYEES SHALL BE BRIEFED ON THESE REQUIREMENTS PRIOR TO WORKING IN THE CONSTRUCTION AREA.
3. CONTRACTOR'S ACCESS TO THE SITE SHALL BE AS SHOWN ON THE PLANS OR AS DIRECTED BY THE RPR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTROLLING ACCESS, AND NOT PERMIT ANY UNAUTHORIZED PERSONNEL OR TRAFFIC ON THE SITE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TRAFFIC CONTROL TO AND FROM THE VARIOUS CONSTRUCTION AREAS ON THE SITE ALONG THE ROUTES
SHOWN IN THE PLANS OR AS DIRECTED BY THE RPR.
4. MATERIALS DELIVERY TO THE SITE: ALL CONTRACTOR'S MATERIAL ORDERS FOR DELIVERY TO THE WORK SITE WILL USE AS A DELIVERY ADDRESS, THE STREET NAME ASSIGNED TO THE ACCESS POINT AT THE CONTRACTOR'S STORAGE SITE AT THE AIRPORT. THE NAME "LAKELAND LINDER INTERNATIONAL AIRPORT" SHALL NOT BE USED IN THE DELIVERY ADDRESS AT ANY TIME. THIS WILL PRECLUDE DELIVERY TRUCKS FROM ENTERING INTO A SECURE AREA OR TAKING SHORT CUTS THROUGH THE PERIMETER GATES AND ENTERING INTO AIRCRAFT
OPERATIONS AREAS INADVERTENTLY.
5. THE LIMITS OF CONSTRUCTION, MATERIAL STORAGE AREAS, EQUIPMENT STORAGE AREA, PARKING AREA AND OTHER AREAS REQUIRED FOR
THE CONTRACTOR'S EXCLUSIVE USE DURING CONSTRUCTION SHALL BE APPROVED BY THE RPR.
6. THE CONTRACTOR, THROUGH THE CONTRACTOR SECURITY OFFICER, SHALL ESTABLISH AND MAINTAIN A LIST OF CONTRACTOR AND SUBCONTRACTOR VEHICLES AUTHORIZED TO OPERATE ON THE SITE. THE CONTRACTOR SECURITY OFFICER WILL REQUIRE ALL VEHICLES OPERATING WITHIN THE A.O.A. SECURITY FENCE TO DISPLAY A LARGE COMPANY SIGN (WITH NOT LESS THAN 6" LETTERING) ON BOTH SIDES OF VEHICLE AND AN AIRPORT APPROVED AMBER FLASHING LIGHT. THE CONTRACTOR SHALL PROVIDE A CURRENT LISTING OF VEHICLES AND COMPANIES AUTHORIZED TO ENTER AND CONDUCT WORK ON THE AIRPORT TO THE RPR. ALL CONSTRUCTION EQUIPMENT OPERATING WITHIN THE AOA FENCE SHALL DISPLAY A 3'X3' ORANGE AND WHITE FAA CHECKERED FLAG DURING DAYLIGHT HOURS AND SHALL DISPLAY A
FLASHING AMBER LIGHT DURING NIGHT-TIME HOURS.
7. CONTRACTOR WILL BE REQUIRED TO OBTAIN AIRPORT SECURITY BADGES TO WORK WITHIN THE A.O.A. ALL VEHICLES OPERATING WITHIN THE A.O.A. SHALL BE OPERATED BY BADGED PERSONNEL HAVING A.O.A. (MOVEMENT OR NON-MOVEMENT) DRIVING PRIVILEGE ONLY OR SHALL BE ESCORTED BY A VEHICLE BEING OPERATED BY AN AUTHORIZED BADGED INDIVIDUAL. ALL CONTRACTOR EMPLOYEES AND SUBCONTRACTOR EMPLOYEES WORKING WITHIN THE A.O.A. SHALL BE BADGED OR SHALL BE UNDER THE DIRECT SUPERVISION OF A
BADGED INDIVIDUAL AT ALL TIMES.
8. CONSTRUCTION BARRICADES SHALL BE PLACED A MINIMUM OF 10FT. OUTSIDE OF ALL INTERSECTING RUNWAY SAFETY AREAS (RSA) AND
TAXIWAY SAFETY AREAS (TSA) AND OUTSIDE OF THE TAXIWAY OBJECT FREE AREAS.
9. CONTRACTOR SHALL COORDINATE THROUGH THE RPR CLOSURES WITH AFFECTED TENANTS AND AIRPORT OPERATIONS. THE CONTRACTOR
SHALL PROVIDE A MINIMUM 48 HOUR NOTICE
10. CONTRACTOR IS REQUIRED TO PROVIDE THE NECESSARY EQUIPMENT (MINIMUM OF TWO WORKING RADIOS) TO MONITOR GROUND CONTROL RADIO COMMUNICATIONS. FREQUENCIES WILL BE PROVIDED BY THE OWNER PRIOR TO THE START OF CONSTRUCTION.
11. CONSTRUCTION EQUIPMENT AND PERSONNEL SHALL YIELD TO AIRCRAFT TRAFFIC AT ALL TIMES.
12. ALL CONSTRUCTION EQUIPMENT MUST MAINTAIN A DISTANCE GREATER THAN 25 FT. FROM ANY PARKED AIRCRAFT.
13. THE CONTRACTOR SHALL NOT ENTER ANY APRON, TAXILANE, TAXIWAY OR RUNWAY OBJECT FREE AREA WITHOUT PRIOR COORDINATION
AND WRITTEN APPROVAL BY THE RPR.
14. IN THE INTEREST OF SAFETY, THE CONTRACTOR IS ALSO REQUIRED TO ACQUAINT HIS/HER EMPLOYEES WITH THE PROVISIONS OF THE
FOLLOWING FEDERAL AVIATION ADMINISTRATION ADVISORY CIRCULARS:
150/5370-2G = OPERATIONAL SAFETY ON AIRPORTS DURING CONSTRUCTION.
150/5210-5D = PAINTING, MARKING AND LIGHTING OF VEHICLES USED ON AN AIRPORT
150/5200-18C = AIRPORT SAFETY SELF-INSPECTION
THE CONTRACTOR SHALL OBTAIN THE LATEST VERSION OF THE FREE ADVISORY CIRCULAR PUBLICATIONS FROM THE FAA ON ITS
WEB SITE AT WWW.FAA.GOV/REGULATIONS_POLICIES/ADVISORY_CIRCULARS/
ENVIRONMENTAL NOTES:
1. NO DISCHARGE OF CONTAMINANTS INTO ADJACENT WETLANDS, WATER BODIES, OR UPLAND BUFFERS WILL BE PERMITTED AT ANY TIME.
2. CONTRACTOR IS RESPONSIBLE FOR OBTAINING NPDES AND ANY POSSIBLE DEWATERING PERMITS FOR PROJECT ACTIVITIES.
3. ALL SURFACE WATER DISCHARGE FROM SITE, INCLUDING DEWATERING DISCHARGE, SHALL MEET CURRENT STATE WATER QUALITY
STANDARDS PRIOR TO REACHING ANY WATERS OF THE STATE INCLUDING WETLANDS.
CITY OF LAKELAND
FEDERAL AVIATION
ADMINISTRATION
SUNSHINE STATE ONE
CALL CENTER OF FLORIDA
AIRPORT ADMINISTRATIONS
AIRPORT OPERATIONS
(863) 834-6000
(866) 835-5322
(800) 432-4770
(863) 834-3298
(863) 834-4911
CONTACT TABLE
ABBREVIATIONS
AOA AIRPORT OPERATIONS AREA
A/C ADVISORY CIRCULAR
B/L BASELINE
CL CENTERLINE
COL CITY OF LAKELAND (OWNER)
CSPP CONSTRUCTION SAFETY AND PHASING PLAN
ELEV ELEVATION
FAA FEDERAL AVIATION ADMINISTRATION
FDOT FLORIDA DEPARTMENT OF TRANSPORTATION
FT FEET
GS GLIDE SLOPE CRITICAL AREA
LT LEFT
MOT MAINTENANCE OF TRAFFIC
NPDES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM
PAPI PRECISION APPROACH PATH INDICATOR
RCP REINFORCED CONCRETE PIPE
ROFA RUNWAY OBJECT FREE AREA
RPR RESIDENT PROJECT REPRESENTATIVE
RSA RUNWAY SAFETY AREA
RT RIGHT
SPCD SAFETY PLAN COMPLIANCE DOCUMENT
SWFWMD SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT
SWPPP STORMWATER POLLUTION PREVENTION PLAN
TLOFA TAXILANE OBJECT FREE AREA
TOFA TAXIWAY OBJECT FREE AREA
TSA TAXIWAY SAFETY AREA
TYP TYPICAL
LEGEND:
EXISTING BUILDING
BENCHMARK
CONTROL POINT
ELECTRICAL MANHOLE
ELECTRICAL TRANSFORMER
ELECTRICAL HANDHOLE
FIRE HYDRANT
GAS METER
GAS VALVE
GATE
GUY WIRE
EXISTING ROUND INLET
EXISTING SQUARE INLET
DOUBLE LIGHT POLE
SINGLE LIGHT POLE
SANITARY SEWER MANHOLE
STORM MANHOLE
POWER POLE
S
ST
SV
W V
WM
G
OHE
UGE
x
FOC
SS
T
W
SANITARY VALVE
ROADWAY SIGN
WATER VALVE
WATER METER
EGAS LINE
OVERHEAD ELECTRICAL
UNDERGROUND ELECTRICAL
EXISTING FENCE
FIBER OPTIC CABLE
PROPERTY LINE
SANITARY SEWER
TOP OF BANK
TOE OF SLOPE
TELEPHONE LINE
WATER LINE
BOLLARD
BID SCHEDULE AND SPECIFICATION NOTES:
1. PAY ITEMS HAVE BEEN ESTABLISHED FOR BIDDING PURPOSES. THE COST FOR ALL WORK INCLUDED IN THE
PROJECT PLANS AND SPECIFICATIONS SHALL BE INCLUDED UNDER THE APPROPRIATE BID ITEM. THE AWARDED CONTRACTOR SHALL BE REQUIRED TO SUBMIT A DETAILED SCHEDULE OF VALUES WHICH SHALL FURTHER DETAIL THESE PAY ITEMS PRIOR TO BEGINNING CONSTRUCTION. SEE PROJECT MANUAL FOR ADDITIONAL INFORMATION.
2. AN ALLOWANCE PAY ITEM HAS BEEN ESTABLISHED FOR WORK ASSOCIATED WITH THE INTEGRATION OF SECURITY AND VIDEO SURVEILLANCE SYSTEMS. THIS FIXED DOLLAR AMOUNT SHALL BE CARRIED IN THE BID BY ALL BIDDERS.
SEE PROJECT MANUAL FOR ADDITIONAL INFORMATION.
3. PAY ITEMS PROVIDED REPRESENT THE TECHNICAL SPECIFICATION THEY ARE MOST CLOSELY ASSOCIATED WITH.
MULTIPLE TECHNICAL SPECIFICATIONS SHALL BE APPLIED TO EACH OF THE WORK ITEMS LISTED IN THE SUMMARY
OF QUANTITIES.
4. FDOT SPECIFICATIONS ARE REFERENCED FOR SOME OF THE SPECIFIED CIVIL SITE WORK. CITY OF LAKELAND UTILITY SPECIFICATIONS SHALL APPLY FOR ALL WATER AND SEWER WORK. SEE PROJECT MANUAL FOR
ADDITIONAL INFORMATION.
FAA
FAA
FAA
FAA
FAA
FAA
X
X
X
X X
XX
X X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X X X X
X
X X
X X
XXX
X X
X
X X X
X X
X
X X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X X
X
XX
X
X
DON EMERSON DR
PARKING LOT
CONTRACTOR
HAUL ROUTE
MAINTENANCE BUILDING
AIRLINE OFFICE
AIRFIELD DR W
D O
N E
M
ER
SO
N
D R
DRANE FIELD RD DRANE FIELD RD
AIR
FIELD
D
RIVE EAST
CONTRACTOR
DELIVERY ACCESS
POINT - GATE 11 (SEE
NOTE 9)
CONTRACTOR
STAGING AREA
EMPLOYEE ACCESS -
GATE 98 (SEE NOTE 10)
TEMPORARY FENCE - SEE
DEMOLITION PLAN FOR
ADDITIONAL INFORMATION
PROJECT LIMITS
TERMINAL BUILDING
CONCRETE APRON
PROPERTY BOUNDARY
PUBLIX CORPORATE PKWY
00 100 200
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead and Hunt, Inc.
© Copyright 2026 Mead & Hunt, Inc.
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
4010 West Boy Scout Blvd, Suite 1000
Tampa, FL 33607 phone: 813-210-8740 meadhunt.com
LA
KE
LA
N
D L
IN
D
ER
IN
TE
R
N
AT
IO
N
AL
AI
R
PO
R T
D O
N E
M
ER
SO
N
D R
, S U
IT
E
LA
KE
LA
N
D , F
L
H O
LD
R
O O
M E
XP
AN
SI
O
N
07/16/26 BID DOCUMENTS
CONTRACTOR LAYOUT
AND PHASING PLAN
G-004
NOT FOR CONSTRUCTION
DSB
DSB
DES
W ed ne sd ay , J ul y
, 2
:4
8:
A M
X:
\4
\2
6.
\T
EC
H \C
AD
\C
AD
F ile s\
Sh ee ts \C on tra ct or
L ay ou t P la n.
dw g
07/16/2026 4667718-261066.01
LEGEND:
CONTRACTOR HAUL ROUTE
CONTRACTOR'S
STAGING AREA
NOTES:
1. THE CONTRACTOR SHALL USE THE STORAGE AND STAGING AREA SPECIFIED FOR STOCKPILES, SHOPS, MAINTENANCE FACILITIES AND ALL OTHER CONTRACTOR SUPPORT FACILITIES. NO OTHER SITES SHALL BE PERMITTED ON AIRPORT
PROPERTY WITHOUT SPECIFIC APPROVAL.
2. ALL COSTS ASSOCIATED WITH PREPARING THE STORAGE AND STAGING AREA AND EMPLOYEE PARKING AREA SITE SHALL BE BORNE BY THE CONTRACTOR. THIS INCLUDES BUT IS NOT LIMITED TO, CONSTRUCTION OF ALL TEMPORARY FACILITIES, EROSION CONTROL, ACCESS ROADS, STORAGE AND STAGING AREA SECURITY FENCING, ETC. THE CONTRACTOR SHALL MAKE PROVISIONS FOR ALL REQUIRED TEMPORARY UTILITIES. ON SITE PARKING OF HEAVY EQUIPMENT WILL BE PERMITTED IN THE CONSTRUCTION AREAS ONLY. CONSTRUCTION VEHICLE PARKING LOCATIONS
SHALL BE DETERMINED AND APPROVED BY RPR.
3. AT THE COMPLETION OF CONTRACT THE CONTRACTOR SHALL RESTORE THE STORAGE AND STAGING AREA AND EMPLOYEE PARKING AREA AND TEMPORARY HAUL ROUTES IN AN EQUAL OR BETTER CONDITION THAN
PRE-CONSTRUCTION. THIS INCLUDES RE-ESTABLISHING ACCEPTABLE TURF.
4. ANY WATER THAT MAY BE REQUIRED ON-SITE FOR CONSTRUCTION PURPOSES SHALL BE OBTAINED FROM THE CITY OF LAKELAND FURNISHED WATER METER. CONSTRUCTION WATER SHALL BE PAID FOR BY CONTRACTOR AND SHALL BE
INCIDENTAL TO THIS CONTRACT.
5. THE CONTRACTOR SHALL PROVIDE TRANSPORTATION TO THE CONSTRUCTION AREA AND FROM THE EMPLOYEE PARKING AREA. PRIVATELY OWNED VEHICLES SHALL NOT BE ALLOWED IN THE CONSTRUCTION AREA. A CLOSER
EMPLOYEE PARKING AREA MAY BE USED IF APPROVED BY THE RPR AND AIRPORT.
6. ALL COSTS FOR SWEEPING, CONTROLLING DUST OR POLLUTANTS TO THE AIR OF ANY KIND SHALL BE CONSIDERED
INCIDENTAL TO THE PROJECT AND NO SEPARATE PAY ITEM SHALL BE PROVIDED.
7. LOCATION OF HAUL ROUTES ON THE AIRPORT SITE SHALL BE AS SHOWN ON DRAWINGS OR AS REQUIRED BY THE ENGINEER. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE OFF-SITE HAUL ROUTES WITH THE APPROPRIATE OWNER WHO HAS JURISDICTION OVER THE AFFECTED ROUTE. ON-SITE ROUTES SHALL BE MAINTAINED BY THE CONTRACTOR AND SHALL BE RESTORED TO THEIR ORIGINAL CONDITION OR TO THE SATISFACTION OF THE
OWNER AT THE END OF CONSTRUCTION.
8. HAUL ROUTES IN PUBLIC RIGHTS-OF-WAY MAY BE SUBJECT TO PERMITTING / APPROVALS BY THE CITY OF LAKELAND, POLK COUNTY, AND FDOT. CONTRACTOR SHALL COORDINATE WITH THOSE AGENCIES AND COMPLY WITH ALL REQUIREMENTS, WHICH MAY INCLUDE, BUT ARE NOT LIMITED TO, OBTAINING ANY REQUIRED PERMITS, WEIGHT OR
HOUR RESTRICTIONS, AND TRAFFIC CONTROL MEASURES.
9. GATE 11 AND THE ASSOCIATED HAUL ROUTE SHALL BE USED FOR THE DELIVERY OF THE MODULAR BUILDING AND OTHER LARGE EQUIPMENT. THESE DELIVERIES SHALL BE COORDINATED WITH THE AIRPORT AND COMPLETED DURING
PERIODS WHEN THERE ARE NO OPERATIONS ON THE RAMP.
10. CONTRACTOR EMPLOYEES SHALL ENTER THE CONSTRUCTION AREA THROUGH THE MANUAL GATE ADJACENT TO THE PROJECT SITE. ACCESS TO THE GATE SHALL BE COORDINATED BY THE CONSTRUCTION SUPERINTENDENT AND/OR
DESIGNATED PERSONNEL AND COORDINATED WITH THE AIRPORT.
PROJECT LIMITS
PHASE 0 /
MOBILIZATION
60 DAYS
TOTAL CONSTRUCTION TIME=
210 CALENDAR DAYS
N O
TI
C
E
TO
P R
O C
EE
D
CONSTRUCTION PHASING DIAGRAM
NOT TO SCALE
30 60 90 1200
SU
BS
TA
N
TI
AL
C O
M
PL
ET
IO
N
PHASE 1
150 DAYS
150 180 210
CONSTRUCTION PHASING NOTES:
MOBILIZATION PHASE (60 CALENDAR DAYS)
THE MOBILIZATION PHASE SHALL BEGIN IMMEDIATELY AFTER THE MOBILIZATION NOTICE TO PROCEED IS ISSUED BY THE AIRPORT. DURING THIS PHASE OF THE PROJECT, NO WORK SHALL BE CONDUCTED THAT RESTRICTS AIRPORT OPERATIONS UNLESS AUTHORIZED BY THE AIRPORT. NOTICE TO PROCEED WITH SUBSEQUENT SCHEDULES MAY BE GIVEN DURING MOBILIZATION AT THE AIRPORTS DISCRETION. MOBILIZATION WORK SHALL INCLUDE, BUT IS NOT LIMITED
TO THE FOLLOWING:
1. SUBMITTALS.
A) PROCESSING OF REQUIRED MATERIALS/EQUIPMENT SUBMITTALS INCLUDING THOSE FOR DELEGATED DESIGN ITEMS AS SPECIFIED IN SPECIFICATION 013573 AND THE CONTRACTOR'S PROPOSED WORK SCHEDULE.
B) ALL ENGINEERING BUILDING DRAWINGS FOR SUBMITTAL TO THE CITY OF LAKELAND TO OBTAIN A CITY BUILDING
PERMIT.
C) MATERIAL DELIVERY SCHEDULE, INCLUDING MATERIAL DELIVERY DATE TO JOB SITE OR TO THE CONTRACTOR'S
YARD.
2. DURING MOBILIZATION, THE CONTRACTOR SHALL BE ALLOWED TO PERFORM LAYOUT, STAKING, AND OTHER PREP
WORK AS APPROVED BY THE AIRPORT.
3. IT IS THE AIRPORT'S INTENT THAT ALL PRELIMINARY WORK BE COMPLETED DURING THE MOBILIZATION PHASE TO ENSURE CONSTRUCTION CAN BE PURSUED DILIGENTLY AND WITHOUT UNNECESSARY DELAY. (THE AIRPORT RESERVES THE RIGHT TO WAIVE CERTAIN ELEMENTS OF MOBILIZATION AND ISSUE A NOTICE TO PROCEED WITH CONSTRUCTION AT ITS DISCRETION OR UPON THE CONTRACTOR'S REQUEST.) SCHEDULE DATE SHALL NOT BE CHANGED, ONCE ESTABLISHED, UNLESS COORDINATION WITH THE CA TEAM AND FINAL APPROVAL OF THE AIRPORT.
PHASE 1 (150 CALENDAR DAYS)
PHASE 1 SHALL CONSIST OF ALL CONSTRUCTION RELATED TO THE PROJECT. THIS TIME PERIOD SHALL INCLUDE PROCUREMENT AND INSTALLATION OF THE MODULAR BUILDING SYSTEM. PHASE 1 SHALL NOT BEGIN UNTIL THE BUILDING PERMIT HAS BEEN CONDITIONALLY APPROVED BY THE CITY AND THE MODULAR BUILDING ELEMENTS ARE APPROVED BY THE OWNER AND ARCHITECT/ENGINEER. DURING PROCUREMENT ALL SITE RELATED WORK SUCH AS INSTALLATION OF TEMPORARY FENCE, SITE UTILITIES (WATER, SEWER, ELECTRICAL SERVICE LINES) AND PREPARATIONS FOR FIRE PROTECTION SYSTEM CONNECTIONS MAY TAKE PLACE. ANY WORK IMPACTING THE EXISTING TERMINAL BUILDING OR OPERATIONS SHALL BE COMPLETED DURING OFF PEAK HOURS AND COORDINATED WITH THE OWNER.
SHEET NO.:
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright Mead & Hunt, Inc.
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
4010 West Boy Scout Blvd, Suite 1000 Tampa, FL 33607 phone: 813-210-8740 meadhunt.com
/1
/2
:2
:0
P
M C
R e v it L o c a l\
.0
A
R k ru th ik a .b h a ra th ra j.
rv t
L A
K E
L A
N D
L
IN
D E
R I
N T
E R
N A
T
IO
N A
L A
IR
P
O R
T
D O
N E
M E
R S
O N
D R
S
U
IT
E
L A
K E
L A
N D
F
L
H O
L D
R O
O M
E X
P A
N S
IO
N
G-011
CODE ANALYSIS
SCHEDULES
NOT FOR CONSTRUCTION
4667719-261066.01
HK
AM
07/16/2026
MMR
2 Recessed fire extinguisher cabinets provided
Other 1 Service Sink 1 Provided NFPA 10
Fountains 1 per 1,000 2 Provided Fire Extinguishers, General
Bathtubs / Showers N/A N/A
Female 1 per 750 2 Provided
Male 1 per 750 2 Provided
Lavatories The design for this project incorporates the accessibility requirements of 2023 Florida Accessibility Code
Female 1 per 500 2 Provided Accessibility Requirements
Male 1 per 500 2 Provided Provided 20 feet
Water Closet
Plumbing counts required for Group A-3 (OL = 303) (A-3, Sprinklered) Distance shall not exceed 20 feet
Plumbing Fixtures FBC Section 1020.4
Sprinklered Dead-end Corridor Distance Type IIB Unprotected Non-Combustible 22,589 (Total) FBC 2018 Table 601 17,637 (Existing)
Construction Type Group A-3, Sprinklered 28,500 4,952 (Addition)
Occupancy Allowable Area (S.F.) Actual Area (S.F.)
With an occupant load of less than 50 36 inches (OL > 50)
IBC Table 1020.5
Existing Building Occupancy: Assembly A-3 (Section 303.4) & Business B (304.1) Allowable Area Factor - FBC Table 506.2 Minimum Corridor Width
FBC Section 303.4, 304.1 : Assembly A-3 (Section 303.4) Building Area
Building Occupancy Classifications:
A-3, Sprinklered with occupant load > 30 0 Hour
2023 Florida Fuel Gas Code Group A-3, Sprinklered 75 3 19'-2" 1
FBC Table 1020.2
Height Stories Height Story
2023 Florida Energy Conservation Code Occupancy
Maximum Allowed Actual Corridor Fire-Resistance Rating
Individual occupancy shall not exceed the height and number of story limits specified in this section.
2023 Florida Accessibility Code
Allowable Number of Stories Above Grade Plane: FBC Table 504.4 Provided: 250 feet
2023 Florida Fire Prevention Code Allowable Height Above Grade Plane: FBC Table 504.3 Sprinklered: A-3 250 feet
Allowable Building Height and Number of Stories FBC Table 1017.2
NFPA 70, National Electrical Code (NEC), 2020 Edition Exit Access Travel Distance X ≥ 30 ft 0 hr 0 hr
2023 Florida Mechanical Code 10 ft ≤ 30 ft 0 hr 0 hr Provided: 75 feet
5 ft ≤ 10 ft 1 hr 1 hr Sprinklered: A-3 75 feet
2023 Florida Plumbing Code X < 5 ft 1 hr 1 hr FBC Table 1006.2.1
Type IIB Construction Group A-3 Provided Common Path of Egress Travel
2023 Florida Existing Building Code Exterior Nonbearing Walls and Partitions where "x" is distance from fire separation
FBC Table 705.5
2023 Florida Building Code (8th Edition) Interior Floor Finish Mininum Critical Radiant Flux: Not less than Class II materials in Group A-3 per FBC 804.4.2.
Floor Construction: 0 hr Rooms and enclosed spaces C C
Applicable Design Criteria and Codes: Interior Nonbearing Walls and Partitions: 0 hr
Interior: 0 hr Corridors and enclosure for exit access stairways and ramps
B B
Exterior: 0 hr
Lakeland, FL 33811 Bearing Walls Interior exit stairway and ramps and exit passageways B B
3900 Don Emerson Drive, Suite 210 Primary Structural Frame: 0 hr
LAL International Airport Holdroom Expansion Project FBC Table 601 Wall and Ceiling Location Group A-3 Provided
FBC Table 803.11 (Building Sprinklered)
Project Name and Location: Fire Resistive Requirements for Building Elements Interior Finishes: Wallls and Ceilings
FIRE PROTECTION AND LIFE SAFETY ANALYSIS FIRE PROTECTION AND LIFE SAFETY ANALYSIS FIRE PROTECTION AND LIFE SAFETY ANALYSIS, CONTINUED
DN
F.E.C.
F .E
.C
UP
ELETRICAL CLOSET
MEN'S
CORRIDOR
WOMEN'S
FAMILY RESTROOM
CORRIDOR
S.A.R.A
JANITOR CLOSET
DEPARTURE LOUNGE
33"
MINIMUM SEPARATION REQUIRED: 42'-2"
EXIT SEPRATION DISTANCE PROVIDED: 78'-0"
33"
CODE PLAN LEGEND:
OCCUPANT LOAD
X
XX"
OCCUPANT LOAD CAPACITY
PROVIDED WIDTH
EXIT DISCHARGE
FIRE EXTINGUISHER -
WALL MOUNTED
FIRE
EXTINGUISHER -
CABINET
1 HR RATED
CEILING SYSTEM
PL
PHOTO LUMINESCENT
EXIT SIGN
EXIT SIGN COMMON PATH
OF TRAVEL
PATH OF TRAVEL
ACCESSIBLE MEANS
OF EGRESS
F.E.
F.E.C.
DOOR RATING (IF RATED)
AIRPORT TERMINAL
WAITING AREAS
15 GROSS
ACCESSORY
STORAGE AREAS
300 GROSS
EXISTING BUILDING
N.I.C.
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright Mead & Hunt, Inc.
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
4010 West Boy Scout Blvd, Suite 1000 Tampa, FL 33607 phone: 813-210-8740 meadhunt.com
/1
/2
:2
:0
P
M C
R e v it L o c a l\
.0
A
R k ru th ik a .b h a ra th ra j.
rv t
L A
K E
L A
N D
L
IN
D E
R I
N T
E R
N A
T
IO
N A
L A
IR
P
O R
T
D O
N E
M E
R S
O N
D R
S
U
IT
E
L A
K E
L A
N D
F
L
H O
L D
R O
O M
E X
P A
N S
IO
N
G-021
LIFE SAFETY AND
OCCUPANCY PLANS
NOT FOR CONSTRUCTION
4667719-261066.01
HK
AM
07/16/2026
MMR
PLAN
NORTH
TRUE
NORTH
1/16" = 1'-0"1
LIFE SAFETY PLAN
OCCUPANT LOAD BY AREA
Area Name Size Function of Area Occupant
Load Factor Gross_or_Net Area
Occupancy
Accessory Storage areas, Mech equipment room
ELECTRICAL CLOSET 55 SF Accessory Storage areas, Mech equipment room 300 Gross 1
JANITOR CLOSET 18 SF Accessory Storage areas, Mech equipment room 300 Gross 1
Airport Terminal - Waiting areas
DEPARTURE LOUNGE 4,512 SF Airport Terminal - Waiting areas 15 Gross 301
TOTAL OCCUPANTS 303
EGRESS DATA
EXIT ROUTE DISTANCE
Common Path of Travel
DEPARTURE LOUNGE (147) 10' - 2"
Path of Travel
DEPARTURE LOUNGE (147) 68' - 2"
OCCUPANCY TYPE SCHEDULE
OCCUPANCY CLASSIFICATION AREA
A-3 4,585 SF
4,585 SF
X
XXX
X X
X X
X
X
B B
BB
XXXXXXXXXXXXXXX
X X
X X
X X
X X
X
X
X
X
X
X
X
E E E E E E E E E E E E E E E E E E
W W W W W W W W W W W W W W W W W W
SS
SS
SS
SS
W W
W
E E
E
E E E
E
SS SS
SS
SS
SS
E
EE
BFPFDC
W W
W W
W W
W W
W W
W
WW
WM
HVAC HVAC
CO
CO
BFP
BFP
WM
FOC FOC FOC FOC FOC
FOC
FOC
FOC
FOC
CO
HVAC
HVAC
CO
WV
WV
Xref C:\Users\04109\Downloads\261066-01_A_R26 - Floor Plan - FLOOR PLAN-260759-01-A-R26_Existing-rvt-1-FLOOR PLAN.dwg
EXISTING FENCE
TO BE REMOVED
EXISTING CONCRETE
RAMP AND HANDRAIL
TO BE REMOVED
EXISTING
ELECTRICAL
LINE TO BE
REMOVED
EXISTING LIGHT POLE TO BE RELOCATED
AND CONCRETE FOUNDATION TO BE
REMOVED TO BE FLUSH OR BELOW
GRADE AND BACKFILLED LEVEL WITH
GRAVEL AS REQUIRED.
EXISTING ELECTRICAL
HANDHOLE TO BE
RELOCATED
EXISTING LIGHT
POLE TO REMAIN
REMOVE EXISTING
GATE (GATE 12)
TEMPORARY FENCE - SEE
DETAIL 1, SHEET C-132
(EXACT LOCATION TO BE
COORDINATED WITH
OPERATIONS TO MINIMALLY
IMPACT TERMINAL APRON)
EX. UNKNOWN
UNDERGROUND UTILITY
(TYP.)
EXISTING LIGHT
POLE TO REMAIN
EX. SIDEWALK
NON-AOA FENCE
EX. TRANSFORMER
TERMINAL EXIT DOOR
EX. 4" SAN
6" WATER MAIN (TERMINAL
BUILDING SERVICE)
EX. SANITARY CLEANOUT
SW INV: 133.33'
WYE W/ CLEAN
OUT INV = 132.97'
PEDESTRIAN
GATE (GATE 98)
EX. 1.5" PVC WATER SERVICE
CONCRETE WALL
WATER VALVE
IN METER BOX
2" PVC WATER
SERVICE LINE
EX. DOMESTIC
BACKFLOW PREVENTER
AND METER ASSEMBLY
EXISTING BUILDING AND
PEDESTAL MOUNTED
ELECTRICAL EQUIPMENT
EX. DOUBLE
SWING GATE
(GATE 97)
EX. 1.5" GATE VALVE
TEMPORARY
DOUBLE 12'
SWING GATE -
SEE DETAIL 1,
SHEET C-132
6" SDR35 PVC
LATERAL
MAINTENANCE BUILDING
AIRLINE OFFICE
ASPHALT APRON
PARKING LOT
CONCRETE APRON
TERMINAL BUILDING
GENERATOR PAD
BEGIN FENCE
REMOVAL
N:1330563.41 E:651314.52
END FENCE
REMOVAL
N:1330607.02 E:651432.03
N:1330531.26 E:651289.59 N:1330531.26
E:651375.25
N:1330560.21 E:651375.20
N:1330560.33 E:651437.54
N:1330578.47 E:651437.41
N:1330578.18 E:651426.66
N:1330578.18 E:651432.08
AIRCRAFT
PARKING
ENVELOPE
00 10 20
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead and Hunt, Inc.
© Copyright 2026 Mead & Hunt, Inc.
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
4010 West Boy Scout Blvd, Suite 1000
Tampa, FL 33607 phone: 813-210-8740 meadhunt.com
LA
KE
LA
N
D L
IN
D
ER
IN
TE
R
N
AT
IO
N
AL
AI
R
PO
R T
D O
N E
M
ER
SO
N
D R
, S U
IT
E
LA
KE
LA
N
D , F
L
H O
LD
R
O O
M E
XP
AN
SI
O
N
07/16/26 BID DOCUMENTS
EXISTING CONDITION
AND DEMOLITION PLAN
C-051
NOT FOR CONSTRUCTION
DSB
DSB
DES
W ed ne sd ay , J ul y
, 2
:4
8:
A M
X:
\4
\2
6.
\T
EC
H \C
AD
\C
AD
F ile s\
Sh ee ts \D em ol iti on
P la n.
dw g
07/16/2026 4667718-261066.01
EXISTING PAVEMENT/GRAVEL
TO BE REMOVED
LEGEND
DEMOLITION/REMOVAL
GENERAL DEMOLITION NOTES
1. LOCATIONS AND SIZES OF ALL EXISTING SURFACE FEATURES, UNDERGROUND UTILITIES AND
STRUCTURES ARE APPROXIMATE AND WERE DETERMINED FROM BEST INFORMATION AVAILABLE
(SURVEY DATA, AS-BUILT DRAWINGS, OR CONSTRUCTION DOCUMENTS). LOCATIONS,
CONFIGURATIONS, SIZES AND MATERIAL TYPES SHOWN MAY NOT MATCH ACTUAL CONDITIONS.
THE CONTRACTOR IS REQUIRED TO VERIFY ALL EXISTING INVERTS, PIPE SIZES AND TYPES
WITHIN THE CONSTRUCTION FOOTPRINT. THE VERIFICATION SHALL BE PROVIDED TO THE RPR IN
THE FORM OF A REPORT. DESIGN OF SHOP DRAWINGS SHALL NOT COMMENCE UNTIL THE
REPORT IS APPROVED IN WRITING BY THE RPR. THE CONTRACTOR SHALL NOTIFY THE ENGINEER
OF ANY CONFLICTS WITH PROPOSED UTILITIES PRIOR TO CONSTRUCTION AND ORDERING
MATERIALS.
2. EXISTING UTILITIES IN THE PROJECT AREA INCLUDE BUT ARE NOT LIMITED TO CRITICAL STORM
DRAINAGE, WATER, GAS, SANITARY SEWER, POWER AND COMMUNICATIONS SYSTEMS. THE
CONTRACTOR SHALL PROTECT AND MAINTAIN ALL EXISTING UTILITIES NOT SHOWN TO BE
REMOVED OR OTHERWISE MODIFIED.
3. ALL UTILITIES NOT SHOWN TO BE REMOVED OR MODIFIED THAT ARE DAMAGED BY THE
CONTRACTOR SHALL BE REPAIRED IMMEDIATELY BY THE CONTRACTOR, TO THE RPR'S
SATISFACTION, AT THE CONTRACTORS EXPENSE. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR THE PROTECTION OF ALL EXISTING UTILITIES SO THEY REMAIN IN SERVICE AT ALL TIMES.
4. EXISTING DUCT BANKS AND STORMWATER UTILITY LINES ARE CRITICAL TO PROPER OPERATION OF THE AIRPORT. EXISTING DUCT BANKS CONTAIN CRITICAL FIBER OPTIC COMMUNICATIONS AND
POWER ESSENTIAL TO THE AIRPORT. THE CONTRACTOR SHALL LOCATE THESE DUCT BANKS AND
UTILITY LINES 15 CALENDAR DAYS PRIOR TO COMMENCING CONSTRUCTION OPERATIONS IN THIS
AREA AND SHALL CONDUCT WORK WITH EXTREME CAUTION. DAMAGE DUE TO THE
CONTRACTOR'S OPERATION SHALL BE REPAIRED IMMEDIATELY AT THE CONTRACTOR'S EXPENSE.
5. SOFT DIGGING OR HAND EXCAVATION MAY BE NECESSARY TO LOCATE EXISTING UTILITIES.
6. CONTRACTOR SHALL IDENTIFY ALL UTILITIES WITHIN THE PROJECT LIMITS AND SUBMIT UTILITY
PROTECTION PLAN FOR REVIEW AND APPROVAL BY THE ENGINEER AND AIRPORT STAFF.
CONTRACTOR SHALL ENSURE THAT ALL ACTIVE EXISTING UTILITIES REMAIN IN SERVICE. THE
CONTRACTOR SHALL MAKE ALL NECESSARY INVESTIGATIONS TO SATISFY HIMSELF AS TO THE
HORIZONTAL LOCATION AND DEPTH OF THE EXISTING UTILITIES. ANY DAMAGE THAT RESULTS
FROM NOT PROPERLY IDENTIFYING UTILITIES SHALL BE REPAIRED AT NO ADDITIONAL COST AND
SHALL INCLUDE ALL NECESSARY WORK ITEMS TO REPAIR THE DAMAGED UTILITY.
7. CONTRACTOR SHALL PROTECT EXISTING PAVEMENT TO REMAIN AND NEWLY CONSTRUCTED
PAVEMENT FROM DAMAGE DURING DEMOLITION WORK. SAWCUT EXISTING PAVEMENT UTILIZING
DOUBLE METHOD WITH AN ADDITIONAL SAWCUT 6 INCHES FROM LIMITS OF PHASED REPAIR
AREA, REGARDLESS OF CONDITION. REMOVE REMAINING ASPHALT PAVEMENT PRIOR TO PAVING
OPERATIONS AND PROVIDE RAMPS TO PROTECT SAWCUT EDGES. RESAW DAMAGED OR BROKEN
AREAS. COORDINATE PAVEMENT SAWCUTS WITH STEP MILLING FOR ASPHALT LIFTS. SEE
TYPICAL SECTIONS AND DETAILS.
8. THE CONTRACTOR SHALL USE PROPER AND EFFECTIVE MEANS AND METHODS DURING
EXCAVATION OF AGGREGATE BASE AND EXISTING SOILS SO THAT OVERBREAK UNDER NEW OR
EXISTING PAVEMENT DOES NOT OCCUR. THE CONTRACTOR SHALL REPAIR ANY AVOIDABLE
OVERBREAK IMMEDIATELY AT NO COST TO THE OWNER.
9. THE CONTRACTOR SHALL CONSTRUCT TEMPORARY FENCE PRIOR TO REMOVING EXISTING
FENCE. THE INSTALLATION OF TEMPORARY FENCING SECURES THE AOA FROM OFFSITE
INCURSIONS.
10. AT NO TIME SHALL THERE BE AN UNSECURED GAP IN THE AIRPORT SECURITY FENCE.
INSTALLATION AND REMOVAL OF TEMPORARY FENCING SHALL BE SUCH THAT THE AIRPORT
REMAINS SECURE AT ALL TIMES. GATES UNDER ACTIVE CONSTRUCTION SHALL BE MONITORED
AND SECURED BY THE CONTRACTOR UNTIL FULLY FUNCTIONAL AND ACCEPTED.
11. ALL TURFED AREAS DISTURBED WITHIN THE PROJECT LIMITS SHALL BE REPLACED WITH
SODDING PER THE REQUIREMENTS OF FDOT SPEC 570 PERFORMANCE TURF. THE COST OF NEW
SOD IS INCIDENTAL TO THE PROJECT AND NO DIRECT PAYMENT SHALL BE MADE.
12. ALL PAVEMENT REMOVED FOR UTILITY INSTALLATION SHALL BE REPLACED IN KIND. THERE SHALL BE NO DIRECT PAYMENT FOR THIS WORK AND COSTS SHALL BE INCLUDED IN THE WORK ITEM IT
IS BEING COMPLETED UNDER. SEE ELECTRICAL AND UTILITY DETAILS FOR ADDITIONAL
INFORMATION ON TRENCH REPAIR REQUIREMENTS.
TEMPORARY CONSTRUCTION
FENCE - SEE DETAIL 1, SHEET
C-132
EXISTING CONCRETE
EXISTING ASPHALT
EXISTING GRAVEL
XXX
X X
X X
X
X
B B
BB
X X
X
X
X
X
X
X
X
E E E E E E E E E E E E E E E E E
W W W W W W W W W W W W W W W W W
SS
SS
SS
SS
W W
W
E
SS SS
SS
SS
SS
E
EE
BFPFDC
W W
W W
W W
W W
W W
W
WW
WM
HVAC HVAC
CO
CO
BFP
BFP
WM
FOC FOC FOC FOC FOC
FOC
FOC
FOC
FOC
CO
HVAC
HVAC
CO
WV
WV
52 SF
ELETRICAL
CLOSET
133 SF
MEN'S
133 SF
WOMEN'S
91 SF
FAMILY
RESTROOM
26 SF
JANITOR
CLOSET
85 SF
S.A.R.A
3,958 SF
DEPARTURE
LOUNGE
52 SF
CORRIDOR
28 SF
CORRIDOR
55 SF
STORAGE
MAINTENANCE BUILDING
AIRLINE OFFICE
CO
W W
W W
E E
E E
E E
E E E E
E E
E E E E E E E E E E
PROPOSED ELECTRICAL
EQUIPMENT RACK - SEE
ELECTRICAL DRAWINGS
BUILDING LIMITS
N:1330541.46 E:651320.77
BUILDING LIMITS
N:1330541.56 E:651369.73
BUILDING LIMITS
N:1330565.65 E:651419.35
PROPOSED CONCRETE
AND BUILDING LIMITS
N:1330602.30 E:651432.04
BUILDING LIMITS
N:1330602.09
E:651320.65
INSTALL NEW AOA
PEDESTRIAN GATE (SEE
GENERAL NOTE 3)
CONNECT TO NEW BUILDING
N:1330563.41 E:651320.06
BUILDING LIMITS
N:1330565.56 E:651369.68
PROPOSED CONCRETE
AND BUILDING LIMITS
N:1330589.67 E:651432.06
CONNECT TO EXISTING
SEWER CLEANOUT
INV ELEV (NE) = 133.43'
EX. INV ELEV (SW) = 133.33'
EX. 6" SDR35
PVC LATERAL
EX. WYE W/ CLEAN
OUT INV = 132.97'
PROPOSED 4" 45
DEGREE BEND
PROPOSED 4" SDR35
PVC LATERAL @ 1%
MIN.
PROPOSED SS CLEANOUT
INV. ELEV = 133.60'
SEE PLUMBING PLANS
FOR CONTINUATIONS (SEE
GENERAL NOTE 1)
SEE PLUMBING PLANS
FOR CONTINUATION
(SEE GENERAL NOTE 1)
NEW 1.5" SCH 40
WATER SERVICE LINE
CONNECT NEW 1.5"
WATERLINE TO EXISTING
SERVICE LINE AT VALVE
IN EXISTING METER BOX
PROPOSED MODULAR BUILDING
HOLD ROOM EXPANSION
FFE = 139.24'
RELOCATED LIGHT POLE
AND NEW ELECTRICAL
HANDHOLE, SEE DETAIL
SHEET C-153
TERMINAL BUILDING
CONCRETE APRON
PROPOSED CONCRETE
PAVEMENT - SEE DETAIL
1, SHEET C-131
PROPOSED CONCRETE
LIMITS
N:1330578.18 E:651432.08
PROPOSED CONCRETE
LIMITS
N:1330578.18 E:651426.66
90 DEGREE BEND
N:1330609.51 E:651315.72
90 DEGREE BEND
N:1330591.07
E:651315.72
CONNECT TO NEW BUILDING
N:1330602.19 E:651373.83
PROPOSED 7' TALL BLACK
VINYL FENCE - SEE DETAILS
SHEET C-131
PROPOSED CONCRETE
LIMITS
N:1330589.66 E:651426.66
PROPOSED ELECTRICAL
CABLE AND CONDUIT TO
NEW LIGHT POLE LOCATION
CONNECT NEW HIGH MAST LIGHT
POLE CIRCUIT TO EXISTING
CIRCUIT AT EXISTING MANHOLE
GENERATOR PAD
AIRCRAFT
PARKING
ENVELOPE
BUILDING LIMITS
N:1330589.65
E:651419.30
PROPOSED ALUMINUM
BOARDING RAMP (SEE
ARCHITECTURAL DRAWINGS)
TIE IN TO
EXISTING FENCE
N:1330606.91 E:651373.82
TIE IN TO
EXISTING FENCE
N:1330563.42 E:651315.06
PROPOSED ELECTRICAL
SERVICE LINE - SEE
ELECTRICAL DRAWINGS
(SEE GENERAL NOTE 8)
PROPOSED EXIT
STAIRWELL (TYP.)
PROPOSED CONCRETE
LIMITS
N:1330607.55 E:651424.03
PROPOSED CONCRETE
LIMITS
N:1330607.54 E:651432.03
PROPOSED CONCRETE
LIMITS
N:1330602.28 E:651424.16
00 10 20
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead and Hunt, Inc.
© Copyright 2026 Mead & Hunt, Inc.
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
4010 West Boy Scout Blvd, Suite 1000
Tampa, FL 33607 phone: 813-210-8740 meadhunt.com
LA
KE
LA
N
D L
IN
D
ER
IN
TE
R
N
AT
IO
N
AL
AI
R
PO
R T
D O
N E
M
ER
SO
N
D R
, S U
IT
E
LA
KE
LA
N
D , F
L
H O
LD
R
O O
M E
XP
AN
SI
O
N
07/16/26 BID DOCUMENTS
LEGEND:
SS
W
E
PROPOSED MODULAR
BUILDING HOLD ROOM
EXPANSION
PROPOSED CONCRETE
PAVEMENT - SEE DETAIL 1,
SHEET C-131
PROPOSED 4" SDR 35 PVC
SANITARY SEWER LINE
PROPOSED 1.5" SCH 40 PVC
WATER SERVICE LINE
PROPOSED ELECTRICAL
CONDUIT
GENERAL NOTES:
1. EXACT LOCATION OF WATER LINE TERMINATION AND SANITARY SEWER CLEANOUT SHOWN ON THIS SHEET TO BE
COORDINATED WITH MODULAR BUILDING PLUMBING PLANS.
2. EXACT BUILDING LIMITS TO BE ESTABLISHED IN CONJUNCTION WITH MODULAR BUILDING MANUFACTURER
DRAWINGS.
3. NEW PEDESTRIAN GATE SHALL BE 5' WIDE, 7' TALL BLACK VINYL WITH 3 STRANDS OF BARBED WIRE. MATCH EXISTING STYLE AND SIZE. EXACT PLACEMENT OF NEW PEDESTRIAN GATE AND AMOUNT OF FENCING REQUIRED SHALL BE COORDINATED WITH CONSTRUCTION OF NEW MODULAR BUILDING. FENCE SHALL BE SECURED TO EXISTING FENCE AND EDGE OF NEW MODULAR BUILDING. SEE DETAIL 5, SHEET C-131. GATE TO HAVE PUSH BUTTON
ACCESS - MATCH EXISTING GATE TYPE AND STYLE.
4. A 4" DEEP LAYER OF #57 STONE GRAVEL (FDOT SECTION 901) OVER FILTER FABRIC IS TO BE PLACED IN ALL AREAS BENEATH MODULAR BUILDINGS AND ASSOCIATED DECKS AND RAMPS THAT ARE NOT ALREADY PAVED OR BEING PAVED PER THE PLAN. THERE SHALL BE NO EXISTING GRASS UNDER THE NEW MODULAR BUILDING.
5. SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATION ON ELECTRICAL REQUIREMENTS FOR RELOCATED HIGH
MAST LIGHT POLE AND POWER DISTRIBUTION.
6. BEARINGS & COORDINATE INFORMATION SHOWN ARE BASED ON NAD 1983 STATE PLANE FLORIDA WEST ZONE, US
FEET (FL83-WF).
7. THE SPACE BETWEEN THE EXISTING GROUND AND BOTTOM OF MODULAR BUILDING SHALL BE FILLED WITH A SOLID SURFACE PER THE ARCHITECTURAL DRAWINGS AND SERVE AS THE NEW AOA LINE. 18" WIDE BY 2" HIGH SLOTS AT 10 FT O.C. SHALL BE CONSTRUCTED ON ALL FACES SO THAT EXISTING DRAINAGE PATTERNS CAN BE MAINTAINED
AND WATER CAN DRAIN UNDER THE NEW MODULAR BUILDING.
8. EXACT LOCATION OF PROPOSED UTILITIES SHALL BE VERIFIED IN THE FIELD IN CONJUNCTION WITH THE LOCATION OF EXISTING UTILITIES AND NEW MODULAR BUILDING. ALL PAVEMENT REMOVED FOR UTILITY INSTALLATION SHALL BE REPLACED IN KIND. THERE SHALL BE NO DIRECT PAYMENT FOR THIS WORK AND COSTS SHALL BE INCLUDED IN THE WORK ITEM IT IS BEING COMPLETED UNDER. SEE ELECTRICAL AND UTILITY DETAILS FOR ADDITIONAL
INFORMATION ON TRENCH REPAIR REQUIREMENTS.
9. ALL TURFED AREAS DISTURBED WITHIN THE PROJECT LIMITS SHALL BE REPLACED WITH SODDING PER THE REQUIREMENTS OF FDOT SPEC 570 PERFORMANCE TURF. THE COST OF NEW SOD IS INCIDENTAL TO THE PROJECT
AND NO DIRECT PAYMENT SHALL BE MADE.
UTILITY CONSTRUCTION NOTES:
1. THE TAP ON WATER MAINS SHALL BE INSTALLED BY CITY OF LAKELAND WATER UTILITIES AT DEVELOPER'S EXPENSE. DEVELOPER SHALL BE RESPONSIBLE FOR EXCAVATION, DEWATERING, RESTORATION AND MOT.
2. A UTILITY CONTRACTOR WILL BE REQUIRED FOR THE INSTALLATION OF THE WATER LINE AND APPURTENANCES.
3. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AT LEAST 48 HOURS PRIOR TO COMMENCEMENT OF
CONSTRUCTION.
4. ALL EXCAVATION SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA TRENCH SAFETY ACT AND OSHA CODE OF REGULATION PART 1926, LATEST REVISION. TRENCH SHALL BE EXCAVATED ONLY SO FAR IN ADVANCE OF PIPE LAYING AS NECESSARY TO INSTALL THE PIPE AT PROPER ALIGNMENT AND DEPTH. PROVIDE CONTINUOUS
BEARING SUPPORT FOR PIPE AND BELL HOLES AT EACH JOINT.
5. AT CROSSINGS, WATER MAINS SHALL HAVE A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION ON CROSSINGS AND MINIMUM OF 10-FOOT HORIZONTAL SEPARATION. AT CROSSINGS, ONE FULL LENGTH OF WATER MAIN PIPE SHALL BE CENTERED AT THE POINT OF CROSSING TO PLACE THE JOINTS AS FAR AS POSSIBLE FROM THE OTHER PIPE, OR THE PIPES SHALL BE ARRANGED SO THAT JOINTS IN THE WATER MAIN ARE AT LEAST THREE FEET FROM ALL JOINTS IN VACUUM SEWERS, STORM SEWERS, OR REGULATED RECLAIMED WATER, AND AT LEAST SIX FEET FROM ALL JOINTS IN GRAVITY SANITARY SEWERS, PRESSURE SEWERS, FORCE MAINS OR PIPES CARRY
UNREGULATED RECLAIMED WATER.
6. THE CONTRACTOR SHALL PROVIDE MECHANICAL RESTRAINED JOINTS AT ALL REDUCERS,TEES, CROSSES,ELBOWS, BLOW-OFFS, FIRE HYDRANTS, DEAD END VALVES AS SPECIFIED IN THE MECHANICAL RESTRAINT SCHEDULE.
7. THE CONTRACTOR SHALL COORDINATE WITH THE SURVEYOR DURING UTILITY CONSTRUCTION TO INSURE THAT ALL REQUIRED AS-BUILT INFORMATION IS OBTAINED PRIOR TO BACKFILLING. THE CITY OF LAKELAND WATER
UTILITIES RECORD DRAWING/AS-BUILT REQUIREMENTS CAN BE FOUND ONLINE AT:
https://www.lakelandgov.net/media/20107/as-built-record-drawing-checklist.pdf
8. THE CONTRACTOR SHALL PROVIDE SKETCH AND DESCRIPTION OF WATER LINE EASEMENT, IF REQUIRED.
9. WHERE A CONNECTION IS TO BE MADE IN THE FIELD TO AN EXISTING PIPE, THE CONTRACTOR SHALL FIELD VERIFY THE EXISTING PIPE SIZE AND MATERIAL AND OBTAIN THE UTILITY OWNER AND ENGINEERS APPROVAL OF THE PROPOSED METHOD OF CONNECTION PRIOR TO ORDERING AND INSTALLING MATERIALS. A CITY OF LAKELAND WATER UTILITIES INSPECTOR SHALL BE PRESENT FOR ANY WORK ON EXISTING PIPES OR MANHOLES.
AS-BUILT SURVEY:
1. THE CONTRACTOR SHALL PROVIDE ENGINEER, UTILITY AND OWNER WITH AN AS-BUILT SURVEY OF ALL NEW UTILITY SYSTEM INFORMATION FROM A REGISTERED SURVEYOR, AT NO ADDITIONAL COST TO THE OWNER. THE AS-BUILT
SURVEY SHALL COMPLY WITH THE CITY UTILITY SPECIFICATIONS.
2. AS-BUILT SURVEYS SHALL ALSO SHOW ANY EXISTING UTILITIES THAT ARE LOCATED DURING CONSTRUCTION.
3. THE AS-BUILT INFORMATION IS DUE PRIOR TO SODDING. CONTRACTOR SHALL PROVIDE SURVEYOR 48-HOUR
NOTICE TO OBTAIN ESSENTIAL LOCATIONS AND ELEVATIONS.
EXISTING SITE CONDITIONS:
LAND/USE CLASSIFICATION: SUBURBAN SPECIAL PURPOSE INDUSTRIAL
SITE AREA: 8,958 SF / .21 AC.
SITE IMPROVEMENTS:
PROPOSED BUILDINGS:
PASSENGER HOLD BUILDING - 5,370 SF
BUILDING HEIGHT:
NUMBER OF STORIES: 1
PROPOSED USE: AVIATION PASSENGER QUEUE
IMPERVIOUS SURFACE AREAS:
BUILDINGS (ADDITIONAL): 98 SF
WATER FACILITIES:
AIRPORT WILL BE THE OWNER OF WATER FACILITIES AND WILL MAINTAIN THEM IN ACCORDANCE WITH THE CITY
POLICY.
WASTEWATER FACILITIES:
AIRPORT WILL BE THE OWNER OF WASTEWATER FACILITIES AND WILL MAINTAIN THEM IN ACCORDANCE WITH THE
CITY POLICY.
ADA ACCESSIBILITY:
ALL COMPONENTS OF THE ACCESSIBLE ROUTE ARE REQUIRED TO MEET THE ACCESSIBILITY CODE SECTION 208
AND CHAPTER 4 AND 5.
PROPOSED SITE AND
UTILITY PLAN
C-121
NOT FOR CONSTRUCTION
DSB
DSB
DES
W ed ne sd ay , J ul y
, 2
:4
9:
A M
X:
\4
\2
6.
\T
EC
H \C
AD
\C
AD
F ile s\
Sh ee ts \P ro po se d
Si te
P la n.
dw g
07/16/2026 4667718-261066.01
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead and Hunt, Inc.
© Copyright 2026 Mead & Hunt, Inc.
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
4010 West Boy Scout Blvd, Suite 1000
Tampa, FL 33607 phone: 813-210-8740 meadhunt.com
LA
KE
LA
N
D L
IN
D
ER
IN
TE
R
N
AT
IO
N
AL
AI
R
PO
R T
D O
N E
M
ER
SO
N
D R
, S U
IT
E
LA
KE
LA
N
D , F
L
H O
LD
R
O O
M E
XP
AN
SI
O
N
07/16/26 BID DOCUMENTS
SITE DETAILS - SHEET 1
C-131
NOT FOR CONSTRUCTION
CPS
DSB
DES
W ed ne sd ay , J ul y
, 2
:4
9:
A M
X:
\4
\2
6.
\T
EC
H \C
AD
\C
AD
F ile s\
Sh ee ts \S ite D et ai ls .d w g
07/16/2026 4667718-261066.01 x x x x x x x x x x x x x x x
1" MIN
2" MAX
2" CHAIN LINK
WIRE MESH
TOP RAIL
NEW MODULAR
BUILDING WALL
1" MIN
2" MAX
TERMINAL POST
x x x
BLACK VINYL CHAIN LINK
FENCE TERMINATION AT BUILDING2 NOT TO SCALE
1/4" DROP PER FOOT MAX SLOPE AWAY FROM BLDG
FA
C
E O
F
EX
IS
TI
N G
B U
IL
D
IN
G
NOTES:
1. MINIMUM PERCENTAGE OF EMBEDDED STEEL TO BE 0.05% OF SLAB CROSS SECTIONAL AREA, OTHER FABRIC SIZES MAY BE USED UPON APPROVAL OF THE CONTRACTING OFFICER.
2. MESH DEPTH TO BE PLACED AT T/4 + 1" AND PLACED BY THE STRIKE-OFF METHOD ON ALL NEW
CONCRETE PAVEMENT.
3. THIS DETAIL APPLIES TO SIDEWALKS, CONCRETE PADS, AND ALL OTHER MISCELLANEOUS
CONCRETE PAVEMENT.
PROPOSED SITE CONCRETE PAVEMENT1 NOT TO SCLAE
COLD APPLIED JOINT
SEALANT (ALL JOINT
LOCATIONS)
REINFORCEMENT
CHAIR (TYP.)
W4 @ 6" WIRE MESH
REINFORCEMENT PER
ASTM A1064
2" RADIUS (TIE INTO
EXISTING GRADE)
6" NEW CONCRETE PAVEMENT
(…