HVAC Drawings.pdf

PDF 534 KB Posted

Attached to
Replace R22 HVAC Systems Phase 2 Federal contract opportunity
Solicitation number
W50S8U-24-B-0002
Issued by
Department of the Army National Guard

About this file

The provided document is a Request for Bids (RFB) for the Replace R22 HVAC Systems Phase 2 project at the Tulsa Air National Guard Base in Oklahoma. The solicitation is for a firm fixed-price contract to replace HVAC units in multiple buildings, including the base CLIN to replace AHU-8 and CU-8 in Building 501, and option line items to replace HVAC units in other buildings. The contract duration is 180 calendar days after notice to proceed. The project is set aside 100% for Small Businesses under NAICS code 238220 with a $19M size standard. Key dates include a site visit on August 5, 2024, RFI close on August 19, 2024, and bid opening on August 28, 2024. The anticipated contract award is prior to, but no later than, September 30, 2024. The solicitation includes a limitation on subcontracting clause and information regarding definitization of equitable adjustments for change orders.

View the file

Other files for this federal contract opportunity

Other files attached to Replace R22 HVAC Systems Phase 2, newest first.
File Type Posted
Sealed Bid OF 1419 HVAC_signed.pdf PDF
Amendment 24-B-0002-0002.pdf PDF
Pre-Bid RFI Log Replace R22 HVAC Systems Phase 2.pdf PDF
Amendment 24-B-0002-0001.pdf PDF
Conform Copy 24-B-0002-0001.pdf PDF
501_AHU_CU-8 - Drawings.pdf PDF
314_CU-1 and CU-2 - Drawings.pdf PDF
Pre-Bid RFI Log Replace R22 HVAC Systems Phase 2.xlsx XLSX spreadsheet
Site Visit Slides HVAC R-22 Phase 2.pdf PDF
Site Visit Sign In HVAC R-22 Phase 2_Redacted.pdf PDF
SoW Base HVAC.pdf PDF
W50S8U-24-B-0002.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CO

M

BA

A IR

M

AND

CO

M

T

AHU-8

1. Replace AHU-8 in the 2nd fl mech room and CU-8 on the roof.

M-101

AutoCAD SHX Text

EAST LEANTO 2ND FLOOR

AutoCAD SHX Text 3/16" = 1'-0"

AutoCAD SHX Text A

AutoCAD SHX Text OKLAHOMA AIR NATIONAL GUARD - 138th FIGHTER WING

AutoCAD SHX Text

DEPARTMENT OF THE ARMY AND THE AIR FORCE

AutoCAD SHX Text

NATIONAL GUARD BUREAU - WASHINGTON,D.C.

AutoCAD SHX Text A-102

AutoCAD SHX Text of sheets

AutoCAD SHX Text

AutoCAD SHX Text 3/16"=1'-0"

AutoCAD SHX Text Checked By:

AutoCAD SHX Text Scale:

AutoCAD SHX Text Sheet

AutoCAD SHX Text Drawn By:

AutoCAD SHX Text

JC

AutoCAD SHX Text

REVISION:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text 8/12/2020

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

TULSA I.A.P., OKLAHOMA

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

BCE: LT COL KURT STEPHENS

AutoCAD SHX Text 138th CIVIL ENGINEER SQUADRON

AutoCAD SHX Text

OKLAHOMA AIR NATIONAL GUARD TULSA I.A.P. OK.

AutoCAD SHX Text

DBCE: MAJ PATRICK DEERING

AutoCAD SHX Text

NORTH

AutoCAD SHX Text E227

AutoCAD SHX Text E228

AutoCAD SHX Text E225

AutoCAD SHX Text E221

AutoCAD SHX Text E223

AutoCAD SHX Text E220

AutoCAD SHX Text E226

AutoCAD SHX Text E211

AutoCAD SHX Text E207

AutoCAD SHX Text E229

AutoCAD SHX Text E201

AutoCAD SHX Text E205

AutoCAD SHX Text E204

AutoCAD SHX Text E206

AutoCAD SHX Text E210

AutoCAD SHX Text E209

AutoCAD SHX Text E208

AutoCAD SHX Text E212

AutoCAD SHX Text E213

AutoCAD SHX Text E214

AutoCAD SHX Text E216

AutoCAD SHX Text E215

AutoCAD SHX Text E217

AutoCAD SHX Text E219

AutoCAD SHX Text E218

AutoCAD SHX Text E222

AutoCAD SHX Text E202

AutoCAD SHX Text E203

AutoCAD SHX Text E224

AutoCAD SHX Text A201

AutoCAD SHX Text

SF

AutoCAD SHX Text

SF

AutoCAD SHX Text

SF

AutoCAD SHX Text

SF

AutoCAD SHX Text

SF

AutoCAD SHX Text

SF

AutoCAD SHX Text

SF

AutoCAD SHX Text

SF

NORTH

A 111

;:i �

A110

II

r I'--_, A112

A 113

HU 12

A 115 A 118 A120

A 121 t:::::::::::.._, \tr::::::=------�====if( C \

LJ n::::::====::;;,�� "!=""--=::;-' Q Q Q A 116

A119 �

�c rl-------' �-----------�11- A123

L':::

A122 n'----------, A124 I-

A114

A117 XXX L___�)

( A109

Ii!

A104

I AHU-11

II II

1. Replace AHU-11 and CU-11.

A107

I

A108

) A103

1J

L.J I

II

ANNEX 1 ST FLOOR

3/16" = 1'-0"

I

A106 XIX u

A105 ( ..:::::i

I- A129 co I-

A126 co

A127

J

A102

' A128

T � � Fl T L

A101

I

:,,:'. 0

DATE: 3/10/2023

REVISION:

Scale: 3/16"=1' -0"

Drawn By: SA

Checked By:

Sheet of -�4�_ sheets

CU -11

AHU -1

AHU -2

CU - 2

CU -1

1. Replace AHU-1 and CU-1.

2. Replace AHU-2 and CU-2. M-103

File details come from the government source that posted it. Updated .