SAT Furniture Appendix A - Concept Drawings 2021-07-12.pdf

PDF 4 MB Posted

Attached to
Furniture and Carpet Replacement, Data Center San Antonio
Solicitation number
HC102821R0055
Issued by

About this file

This set of construction drawings and specifications calls for the replacement of systems furniture, carpet tiles, and suspended ceiling panels throughout administrative areas at the Defense Information Systems Agency Data Center in San Antonio, Texas. The solicitation seeks offers to remove existing furniture and install new cubicles, console workstations, semi-private offices, demountable wall partitions, and chairs. Bidders must also replace carpet tiles, wall base, and ceiling panels. Electrical and communication cabling connections are required. The pre-proposal site visit date is listed in the pre-proposal document. Questions are due after the site visit. Offers are due on the date specified in the pre-proposal site visit documentation.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

44 35

El Paso

Amarillo

Lubbock

Abilene

Dallas

Waco

Austin

San Antonio

Houston

LOCATION MAP

PROJECT

LOCATION

Laredo

N.T.S.

PROJECT LOCATION

CLARENCE TINKER DRIVE

GENERAL HUDNELL DRIVE

DEFENSE INFORMATION SYSTEMS AGENCY

FURNITURE AND CARPET REPLACEMENT

APPENDIX A - CONCEPT DRAWINGS

DATA CENTER SAN ANTONIO (BLDG 200)

COVER SHEET

SHEET

IDENTIFICATION

D

ES

IG

N

B Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

PL

O

T

SC

AL

E:

SI

ZE

AN

SI

D

C H

EC

KE

D B

Y:

PL

O

T D

AT

E:

FI

LE

N

AM

E:

SU

BM

IT

TA

L D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E:

AP

PR

:M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E:

AP

PR

B

C

D

1 2 3 4 5

1 2 3 4 5

Defense Information Systems Agency A Combat Support Agency

A

B

D

C

P.

O

.B O

X

G

R

EE

N W

O O

D V

IL

LA

G E

SE

L

F

AC

IL

IT

ES

EN

G

IN

EE

R

IN

G

C O

.8

* FOR OFFICIAL USE ONLY *

* FOR OFFICIAL USE ONLY *

A

SC

H

EM

AT

IC

D

ES

IG

N

M H

B

AK

S

N /A

AS

S

H O

W N

JE

S

5/ 6/

G -0

N /A

N /A

N /A

4/

/2

G-001

D

AT

A C

EN

TE

R S

AN

A

N

TO

N

IO

FU

R

N

IT

U R

E

AN

D C

AR

PE

T R

EP

LA

C

EM

EN

T

C O

VE

R

S H

EE

T

DATE: 6 May 2021

NORTH

SHEET

IDENTIFICATION

D

ES

IG

N

B Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

PL

O

T

SC

AL

E:

SI

ZE

AN

SI

D

C H

EC

KE

D B

Y:

PL

O

T D

AT

E:

FI

LE

N

AM

E:

SU

BM

IT

TA

L D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E:

AP

PR

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E:

AP

PR

B

C

D

1 2 3 4 5

1 2 3 4 5

Defense Information Systems Agency A Combat Support Agency

A

B

D

C

P.

O

.B O

X

G

R

EE

N W

O O

D V

IL

LA

G E

SE

L

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

.8

234567 14 13 12 11 10 9 8

* FOR OFFICIAL USE ONLY *

* FOR OFFICIAL USE ONLY *

A

G-002

D

AT

A

C

EN

TE

R

S

AN

A N

TO

N

IO

F

U R

N

IT

U R

E

AN

D C

AR

PE

T R

EP

LA

C

EM

EN

T

AR

C

H

IT

EC

TU

R

AL

L

EG

EN

D

S

H

EE

T

IN

D

EX

M H

B

AK

S

N /A

AS

S

H O

W N

JE

S

5/ 6/

SA

T_

M D

A -L

G

1.

D

W G

N /A

N /A

N /A

4/

/2

LEGEND AND SHEET INDEX

ABOVE FINISHED FLOOR

APPROXIMATE

BOARD

BUILDING

BOTTOM OF

CONSTRUCTION JOINT

CEILING

CONCRETE MASONRY UNIT

DRAIN

DETAIL

DIAMETER

DEFENSE INFORMATION

SYSTEMS AGENCY

DRAWING

EACH

EXHAUST FAN

EXPANSION JOINT

ELECTRICAL

EQUAL

EXISTING

EXTERIOR

FLOOR DRAIN

FOUNDATION

FIRE EXTINGUISHER CABINET

FINISH FLOOR

FEET

GAGE/GAUGE

GALLON

GENERAL CONTRACTOR

GOVERNMENT FURNISHED

CONTRACTOR INSTALLED

GYPSUM BOARD

HANDICAPPED

HUMIDIFIER

HEIGHT

HEATING/ VENTILATION/

AIR CONDITIONING

INCHES

INSULATION

KILOWATT

LAVATORY

MAXIMUM

MECHANICAL

MANUFACTURER

MINIMUM

MISCELLANEOUS

NOT AVAILABLE

NOT IN CONTRACT

NOT TO SCALE

ON CENTER

OVERHEAD

OVERHEAD DOOR

PLASTIC LAMINATE

QUANTITY

ROOF DRAIN

RECIRCULATING

REQUIRED

ROOM

ROUGH OPENING

SUSPENDED ACOUSTICAL GRID

SIMILAR

SQUARE

SUSPENDED

TOP OF

TYPICAL

UNLESS NOTED OTHERWISE

UNINTERRUPTIBLE POWER SUPPLY

VARIABLE AIR VOLUME

VINYL COMPOSITION TILE

VENTILATING FAN

WITH

WOOD

AFF

APPROX

BD

BLDG

B.O.

CJ

CLG

CMU

D

DET

DIA

DISA

DWG

EA

EF

EJ

ELEC

EQ

EXIST

EXT

FD

FDTN

FEC

FF

FT

GA

GAL

GC

GFCI

GYP BD

HC

HUM

HT

HX

IN

INSUL

KW

LAV

MAX

MECH

MFR

MIN

MISC

NA

NIC

NTS

OC

OH

OHD

PLAM

QTY

RD

RECIRC

REQD

RM

RO

SAG

SIM

SQ

SUSP

T.O.

TYP

UNO

UPS

VAV

VCT

VF

W/

WD

SYMBOLS ABBREVIATIONS

NAME

XXX

PLAN REFERENCE

NORTH

GYP BD CEILING

URINAL

TOILET

SINK

RECESSED CAN LIGHT

WINDOW

DOOR

2x2 LIGHT

1x4 LIGHT

2x4 LIGHT

SITE LIGHTING

WALL MOUNTED LIGHT

SAG CEILING GRID

ROOM NAME & NUMBER

NORTH ARROW

BOLLARD BARRIER

PROTECTIVE FENCING

PARKING SPACE

PAVED WALKWAY

JERSEY BARRIER

RAILROAD TRACK

LIFT ARM BARRIER

1x4 SUSPENDED LIGHT

FLOOD LIGHT

RETURN GRILL

SUPPLY GRILL

COOLING FAN

ERV

SRV

ROOF VENTILATION FAN

ROOF VENTILATION INTAKE

DATE: 6 May 2021

SHEET LIST TABLE

Sheet Number Sheet Title

GENERAL

G-001 COVER SHEET

G-002 LEGEND AND SHEET INDEX

INTERIORS

ID-100 FURNITURE DEMOLITION PLAN - AREA A

ID-101 FURNITURE DEMOLITION PLAN - AREA C

I-100 CARPET AND CEILING REPLACEMENT PLAN - AREA A

I-101 CARPET AND CEILING REPLACEMENT PLAN - AREA C

I-102 FURNITURE FLOOR PLAN - AREA A

I-103 FURNITURE FLOOR PLAN - AREA C

INTERIORS: DETAILS

I-500 FURNITURE DETAILS

I-501 OFFICE DETAILS

I-104 CABLE TRAY LAYOUT PLAN - AREA C

TRUE

5a

3b

4a

5b

3c

ST

AI

R S

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

OFFICE

CONFERENCE

PROJECTOR

STORAGE

MENS

WOMENS

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

NIPR COMPUTING SPACE

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

CONFERENCE

OFFICE

CORRIDOR

CONFERENCE

PROJECTOR

107CONFERENCE

STORAGE

MENS

WOMENS

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

NIPR COMPUTING SPACE

OFFICE

XXX

OFFICE

XXX

SHEET

IDENTIFICATION

D

ES

IG

N

B Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

PL

O

T

SC

AL

E:

SI

ZE

AN

SI

D

C H

EC

KE

D B

Y:

PL

O

T D

AT

E:

FI

LE

N

AM

E:

SU

BM

IT

TA

L D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E:

AP

PR

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E:

AP

PR

B

C

D

1 2 3 4 5

1 2 3 4 5

Defense Information Systems Agency A Combat Support Agency

A

B

D

C

P.

O

.B O

X

G

R

EE

N W

O O

D V

IL

LA

G E

SE

L

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

.8

234567 14 13 12 11 10 9 8

* FOR OFFICIAL USE ONLY *

* FOR OFFICIAL USE ONLY *

ID-100

A

C

EN

TE

R

S

AN

A N

TO

N

IO

FU

R N

IT

U

R E

AN

D

C

AR

PE

T

R

EP

LA

C

EM

EN

T

FU

R

N

IT

U R

E D

EM

O

LI

TI

O N

P

LA

N

AR

EA

A

M H

B

AK

S

AS

S

H O

W N

JE

S

5/ 6/

ID

-1

.D

W G

N /A

N /A

N /A

5/ 6/

FURNITURE DEMOLITION PLAN - AREA A

SCALE : 1/8" = 1'-0"

1. COMPLETELY REMOVE EXISTING FURNITURE AS PER THE

APPROVED PHASING PLAN.

2. EXISTING FURNITURE TO REMAIN. REMOVE AND REINSTALL AS

NEEDED FOR REPLACEMENT OF CARPET FLOORING, WALL

BASE, AND CEILING PANELS.

3. REMOVE EXISTING COMMUNICATION CABLING TO EXISTING

FURNITURE (OFFICES AND CONFERENCE ROOMS).

KEYNOTES

GENERAL NOTES

0 4' 8' 16'

KEY PLAN

SCALE: NTS

A B

C D

PLAN

NORTH

1. THE GOVERNMENT WILL OCCUPY THE BUILDING DURING

THIS PROJECT. WORK SHALL BE COORDINATED WITH SITE

POC AND SHALL FOLLOW THE APPROVED PHASING PLAN.

2. CONTRACTOR SHALL PROTECT EXISTING SURFACES TO

REMAIN. REPAIR OR REPLACE ANY DAMAGE CAUSED BY

DEMOLITION WORK.

3. REMOVE EXISTING ELECTRICAL FOR FURNITURE BACK TO

THE SOURCE (PANEL OR JUNCTION BOX).

4. REMOVE EXISTING COMMUNICATION CABLING FROM

FURNITURE AND BACK TO THE SOURCE.

TYPICAL

CONTINUED ON

DWG. ID-101

TYPICAL

TYPICAL

TYPICAL

TYPICAL

TYPICAL

TYPICAL

TYPICAL

TYPICAL

B CA FD EA1

CONFERENCE

PROJECTOR

STORAGE

MENS

WOMENS

OFFICE

OFFICE

VESTIBULE

LOBBY

TELECOM/COMM

CORRIDOR

115A

WOMENS

JANITOR

CORRIDOR

153A

SIPR OPEN STORAGE/OFFICE

STORAGE

STORAGE

STORAGE

CORRIDOR

VESTIBULE

OFFICE

CORRIDOR

145B

CORRIDOR

145A

MENS

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE

CORRIDOR

CONFERENCE

PROJECTOR

107CONFERENCE

STORAGE

OFFICE

MENS

WOMENS

OFFICE

OFFICE

VESTIBULE

LOBBY

TELECOM/COMM

OFFICE

CORRIDOR

115A

VESTIBULE

WOMENS

MENS

JANITOR

CORRIDOR

153A

BREAK

SIPR OPEN STORAGE/OFFICE

STORAGE

STORAGE

STORAGE

CORRIDOR

VESTIBULE

OFFICE

OFFICE

CORRIDOR

145B

CORRIDOR

145A

MENS

WOMENS

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE

SHEET

IDENTIFICATION

D

ES

IG

N

B Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

PL

O

T

SC

AL

E:

SI

ZE

AN

SI

D

C H

EC

KE

D B

Y:

PL

O

T D

AT

E:

FI

LE

N

AM

E:

SU

BM

IT

TA

L D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E:

AP

PR

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E:

AP

PR

B

C

D

1 2 3 4 5

1 2 3 4 5

Defense Information Systems Agency A Combat Support Agency

A

B

D

C

P.

O

.B O

X

G

R

EE

N W

O O

D V

IL

LA

G E

SE

L

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

.8

234567 14 13 12 11 10 9 8

* FOR OFFICIAL USE ONLY *

* FOR OFFICIAL USE ONLY *

ID-101

A

C

EN

TE

R

S

AN

A N

TO

N

IO

FU

R N

IT

U

R E

AN

D

C

AR

PE

T

R

EP

LA

C

EM

EN

T

FU

R

N

IT

U R

E D

EM

O

LI

TI

O N

P

LA

N

AR

EA

C

M H

B

AK

S

AS

S

H O

W N

JE

S

5/ 6/

ID

-1

.D

W G

N /A

N /A

N /A

5/ 6/

FURNITURE DEMOLITION PLAN - AREA C

SCALE : 1/8" = 1'-0" 0 4' 8' 16'

KEY PLAN

SCALE: NTS

A B

C D

1. COMPLETELY REMOVE EXISTING FURNITURE AS PER THE

APPROVED PHASING PLAN.

2. EXISTING FURNITURE TO REMAIN. REMOVE AND REINSTALL AS

NEEDED FOR REPLACEMENT OF CARPET FLOORING, WALL

BASE, AND CEILING PANELS.

3. REMOVE EXISTING COMMUNICATION CABLING TO EXISTING

FURNITURE (OFFICES AND CONFERENCE ROOMS).

KEYNOTES

GENERAL NOTES

1. THE GOVERNMENT WILL OCCUPY THE BUILDING DURING

THIS PROJECT. WORK SHALL BE COORDINATED WITH SITE

POC AND SHALL FOLLOW THE APPROVED PHASING PLAN.

2. CONTRACTOR SHALL PROTECT EXISTING SURFACES TO

REMAIN. REPAIR OR REPLACE ANY DAMAGE CAUSED BY

DEMOLITION WORK.

3. REMOVE EXISTING ELECTRICAL FOR FURNITURE BACK TO

THE SOURCE (PANEL OR JUNCTION BOX).

4. REMOVE EXISTING COMMUNICATION CABLING FROM

FURNITURE AND BACK TO THE SOURCE.

CONTINUED ON

DWG. ID-100

TYPICAL

TYPICAL

TYPICAL

TYPICAL 1

TYPICAL

TYPICAL

TYPICAL

TYPICAL

TYPICAL

TYPICAL

TYPICAL

TYPICAL

TYPICAL

TYPICAL

TYPICAL

DATE: 6 May 2021

PLAN

5a

3b

4a

5b

3c

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

OFFICE

CORRIDOR

CONFERENCE

STORAGE

OFFICE

MENS

WOMENS

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

OFFICE

CONFERENCE

STORAGE

OFFICE

MENS

WOMENS

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

OFFICE

CONFERENCE

CONFERENCE

STORAGE

OFFICE

MENS

WOMENS

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

OFFICE

CONFERENCE

STORAGE

MENS

WOMENS

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

CONFERENCE

OFFICE

CONFERENCE

PROJECTOR

STORAGE

MENS

WOMENS

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

OFFICE

CONFERENCE

STORAGE

MENS

WOMENS

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

CONFERENCE

OFFICE

CORRIDOR

CONFERENCE

STORAGE

OFFICE

MENS

WOMENS

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

OFFICE

XXX

OFFICE

XXX

OFFICE

XXX

OFFICE

XXX

SHEET

IDENTIFICATION

D

ES

IG

N

B Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

PL

O

T

SC

AL

E:

SI

ZE

AN

SI

D

C H

EC

KE

D B

Y:

PL

O

T D

AT

E:

FI

LE

N

AM

E:

SU

BM

IT

TA

L D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E:

AP

PR

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E:

AP

PR

B

C

D

1 2 3 4 5

1 2 3 4 5

Defense Information Systems Agency A Combat Support Agency

A

B

D

C

P.

O

.B O

X

G

R

EE

N W

O O

D V

IL

LA

G E

SE

L

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

.8

234567 14 13 12 11 10 9 8

* FOR OFFICIAL USE ONLY *

* FOR OFFICIAL USE ONLY *

I-100

A

C

EN

TE

R

S

AN

A N

TO

N

IO

FU

R N

IT

U

R E

AN

D

C

AR

PE

T

R

EP

LA

C

EM

EN

T

CA

RP

ET

A

ND

C

EI

LIN

G

RE

PL

AC

EM

EN

T

PL

AN

AR

EA

A

M H

B

AK

S

AS

S

H O

W N

JE

S

5/ 6/

I-1

.D W

G

N /A

N /A

N /A

5/ 6/

0 4' 8' 16'

CARPET AND CEILING REPLACEMENT PLAN - AREA A

SCALE : 1/8" = 1'-0"

1. COMPLETELY REMOVE EXISTING CARPET FLOORING AND

EXISTING WALL BASE.

2. COMPLETELY REMOVE EXISTING CEILING PANELS. TEMPORARY

SUPPORT EXISTING CEILING MOUNTED ITEMS (LIGHTS,

MECHANICAL, FIRE SPRINKLERS, EXIT SIGNS, EXIT LIGHTING,

DETECTION EQUIPMENT, SPEAKERS AND OTHER EXISTING

ITEMS). ALL EXISTING ITEMS MUST REMAIN OPERATIONAL

DURING THE PROJECT.

3. INSTALL NEW APPROVED CEILING PANELS, CAREFULLY

INCORPORATING EXISTING CEILING MOUNTED ITEMS. INSTALL

EXISTING CEILING MOUNTED ITEMS IN ITS ORIGINAL LOCATION

UNLESS OTHERWISE DIRECTED BY SITE POC.

4. INSTALL APPROVED CARPET TILES AND WALL BASE.

5. REMOVE AND REINSTALL EXISTING FURNITURE AS REQUIRED

FOR CARPET FLOORING AND CEILING WORK.

KEYNOTES

GENERAL NOTES

1. THE GOVERNMENT WILL OCCUPY THE BUILDING DURING THIS

PROJECT. WORK SHALL BE COORDINATED WITH SITE POC AND

SHALL FOLLOW THE APPROVED PHASING PLAN.

2. CONTRACTOR SHALL PROTECT EXISTING SURFACES TO

REMAIN. PATCH, REPAIR OR REPLACE ANY DAMAGED

SURFACES.

3. COMPLETELY REMOVE EXISTING CARPET FLOORING AND WALL

BASE. SCRAPE AND CLEAN EXISTING FLOOR SURFACE FOR

CARPET INSTALLATION. PATCH AND REPAIR EXISTING WALL

SURFACES FOR INSTALLATION OF NEW WALL BASE.

4. COMPLETELY REMOVE EXISTING CEILING PANELS. EXISTING

METAL CEILING GRID TO REMAIN, PATCH, REPAIR OR REPLACE

AS REQUIRED.

KEY PLAN

SCALE: NTS

A B

C D

AREA OF CARPET, WALL BASE AND

CEILING PANEL REPLACEMENT

1 32 4

TYPICAL

1 32 4

TYPICAL

CONTINUED ON

DWG. I-101

DATE: 6 May 2021

1 32 4

TYPICAL

1 32 4

TYPICAL

1 32 4

TYPICAL

1a

2a

3b

1b

3a

3c

B CA FD EA1

CORRIDOR

CONFERENCE

STORAGE

OFFICE

MENS

WOMENS

OFFICE

VESTIBULE

LOBBY

TELECOM/COMM

CORRIDOR

115A

WOMENS

MENS

JANITOR

CORRIDOR

153A

SIPR OPEN STORAGE/OFFICE

STORAGE

STORAGE

STORAGE

OFFICE

MENS

WOMENS

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE

CONFERENCE

STORAGE

OFFICE

MENS

WOMENS

OFFICE

VESTIBULE

LOBBY

TELECOM/COMM

CORRIDOR

115A

WOMENS

MENS

JANITOR

CORRIDOR

153A

SIPR OPEN STORAGE/OFFICE

STORAGE

STORAGE

STORAGE

OFFICE

MENS

WOMENS

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE

CONFERENCE

CONFERENCE

STORAGE

OFFICE

MENS

WOMENS

OFFICE

VESTIBULE

LOBBY

TELECOM/COMM

CORRIDOR

115A

WOMENS

MENS

JANITOR

CORRIDOR

153A

SIPR OPEN STORAGE/OFFICE

STORAGE

STORAGE

STORAGE

OFFICE

MENS

WOMENS

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE

CONFERENCE

STORAGE

MENS

WOMENS

OFFICE

OFFICE

VESTIBULE

LOBBY

TELECOM/COMM

CORRIDOR

115A

WOMENS

JANITOR

CORRIDOR

153A

SIPR OPEN STORAGE/OFFICE

STORAGE

STORAGE

STORAGE

OFFICE

MENS

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE

CONFERENCE

PROJECTOR

STORAGE

MENS

WOMENS

OFFICE

OFFICE

VESTIBULE

LOBBY

TELECOM/COMM

CORRIDOR

115A

VESTIBULE

WOMENS

JANITOR

CORRIDOR

153A

BREAK

SIPR OPEN STORAGE/OFFICE

STORAGE

STORAGE

STORAGE

OFFICE

OFFICE

MENS

WOMENS

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE

CONFERENCE

STORAGE

MENS

WOMENS

OFFICE

OFFICE

VESTIBULE

LOBBY

TELECOM/COMM

CORRIDOR

115A

WOMENS

JANITOR

CORRIDOR

153A

SIPR OPEN STORAGE/OFFICE

STORAGE

STORAGE

STORAGE

OFFICE

MENS

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE

CORRIDOR

CONFERENCE

STORAGE

OFFICE

MENS

WOMENS

OFFICE

OFFICE

VESTIBULE

LOBBY

TELECOM/COMM

OFFICE

CORRIDOR

115A

VESTIBULE

WOMENS

MENS

JANITOR

CORRIDOR

153A

BREAK

SIPR OPEN STORAGE/OFFICE

STORAGE

STORAGE

STORAGE

OFFICE

OFFICE

MENS

WOMENS

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE

SHEET

IDENTIFICATION

D

ES

IG

N

B Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

PL

O

T

SC

AL

E:

SI

ZE

AN

SI

D

C H

EC

KE

D B

Y:

PL

O

T D

AT

E:

FI

LE

N

AM

E:

SU

BM

IT

TA

L D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E:

AP

PR

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E:

AP

PR

B

C

D

1 2 3 4 5

1 2 3 4 5

Defense Information Systems Agency A Combat Support Agency

A

B

D

C

P.

O

.B O

X

G

R

EE

N W

O O

D V

IL

LA

G E

SE

L

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

.8

234567 14 13 12 11 10 9 8

* FOR OFFICIAL USE ONLY *

* FOR OFFICIAL USE ONLY *

I-101

A

C

EN

TE

R

S

AN

A N

TO

N

IO

FU

R N

IT

U

R E

AN

D

C

AR

PE

T

R

EP

LA

C

EM

EN

T

CA

RP

ET

A

ND

C

EI

LIN

G

RE

PL

AC

EM

EN

T

PL

AN

AR

EA

C

M H

B

AK

S

AS

S

H O

W N

JE

S

5/ 6/

I-1

.D W

G

N /A

N /A

N /A

5/ 6/

0 4' 8' 16'

CARPET AND CEILING REPLACEMENT PLAN - AREA C

SCALE : 1/8" = 1'-0" KEY PLAN

SCALE: NTS

A B

C D

1. COMPLETELY REMOVE EXISTING CARPET FLOORING AND

EXISTING WALL BASE.

2. COMPLETELY REMOVE EXISTING CEILING PANELS. TEMPORARY

SUPPORT EXISTING CEILING MOUNTED ITEMS (LIGHTS,

MECHANICAL, FIRE SPRINKLERS, EXIT SIGNS, EXIT LIGHTING,

DETECTION EQUIPMENT, SPEAKERS AND OTHER EXISTING

ITEMS). ALL EXISTING ITEMS MUST REMAIN OPERATIONAL

DURING THE PROJECT.

3. INSTALL NEW APPROVED CEILING PANELS, CAREFULLY

INCORPORATING EXISTING CEILING MOUNTED ITEMS. INSTALL

EXISTING CEILING MOUNTED ITEMS IN ITS ORIGINAL LOCATION

UNLESS OTHERWISE DIRECTED BY SITE POC.

4. INSTALL APPROVED CARPET TILES AND WALL BASE.

5. REMOVE AND REINSTALL EXISTING FURNITURE AS REQUIRED

FOR CARPET FLOORING AND CEILING WORK.

KEYNOTES

GENERAL NOTES

1. THE GOVERNMENT WILL OCCUPY THE BUILDING DURING THIS

PROJECT. WORK SHALL BE COORDINATED WITH SITE POC AND

SHALL FOLLOW THE APPROVED PHASING PLAN.

2. CONTRACTOR SHALL PROTECT EXISTING SURFACES TO

REMAIN. PATCH, REPAIR OR REPLACE ANY DAMAGED

SURFACES.

3. COMPLETELY REMOVE EXISTING CARPET FLOORING AND WALL

BASE. SCRAPE AND CLEAN EXISTING FLOOR SURFACE FOR

CARPET INSTALLATION. PATCH AND REPAIR EXISTING WALL

SURFACES FOR INSTALLATION OF NEW WALL BASE.

4. COMPLETELY REMOVE EXISTING CEILING PANELS. EXISTING

METAL CEILING GRID TO REMAIN, PATCH, REPAIR OR REPLACE

AS REQUIRED.

AREA OF CARPET, WALL BASE, AND

CEILING PANEL REPLACEMENT

1 32 4

TYPICAL

1 32 4

TYPICAL

CONTINUED ON

DWG. I-100

DATE: 6 May 2021

1 32 4

TYPICAL

1 32 4

TYPICAL

TYPICAL

TYPICAL

TYPICAL

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

CONFERENCE

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

CONFERENCE

OPERATIONS

CORRIDOR

CONFERENCE

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

5a

4a

5b

OPERATIONS

A-8

COMM

A-7

PROJECTOR

STORAGE

SHEET

IDENTIFICATION

D

ES

IG

N

B Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

PL

O

T

SC

AL

E:

SI

ZE

AN

SI

D

C H

EC

KE

D B

Y:

PL

O

T D

AT

E:

FI

LE

N

AM

E:

SU

BM

IT

TA

L D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E:

AP

PR

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E:

AP

PR

B

C

D

1 2 3 4 5

1 2 3 4 5

Defense Information Systems Agency A Combat Support Agency

A

B

D

C

P.

O

.B O

X

G

R

EE

N W

O O

D V

IL

LA

G E

SE

L

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

.8

234567 14 13 12 11 10 9 8

* FOR OFFICIAL USE ONLY *

* FOR OFFICIAL USE ONLY *

I-102

A

C

EN

TE

R

S

AN

A N

TO

N

IO

FU

R N

IT

U

R E

AN

D

C

AR

PE

T

R

EP

LA

C

EM

EN

T

FU

R

N

IT

U R

E

FL

O O

R P

LA

N

AR

EA

A

- AK

S

AS

S

H O

W N

JE

S

- SA

T

- F U

R N

IT

U

R E

LA

YO

U T.

D W

G

N /A

N /A

N /A

0 4' 8' 16'

FURNITURE FLOOR PLAN - AREA A

SCALE : 1/8" = 1'-0"

KEY PLAN

SCALE: NTS

Date: 12 July 2021

A B

C D

1. INSTALL TYPICAL 6' X 6' CUBICLE, SEE TYPICAL DETAIL 1/i-500.

2. INSTALL TYPICAL 5'-0" CONSOLE, SEE TYPICAL DETAIL 1/I-500.

3. INSTALL TYPICAL 7'-6" CONSOLE, SEE TYPICAL DETAIL 4/I-500.

4. INSTALL TYPICAL SEMI-PRIVATE OFFICE, SEE DETAIL 4/I-500.

5. INSTALL TYPICAL TEAMING ROOM, SEE DETAIL 5/I-500.

6. INSTALL FULL HEIGHT DEMOUNTABLE PARTITION. COORDINATE

WITH EXISTING CEILING ITEMS TO COORDINATE FINAL LOCATION

WITH THE SITE POC.

7. INSTALL 3'-0" X 7'-0" DOOR, FRAME AND HARDWARE IN

DEMOUNTABLE PARTITION.

8. INSTALL PRINT AREA. PRINT AREA SHALL INCLUD 6'-0" WIDE X 1'-6"

DEEP WORK SURFACE WITH UNDERWORK SURFACE STORAGE

CABINETS WITH DOORS.

9. INSTALL TWO (2) 3'-0" WIDE X 1'-6" DEEP X 4'-8" TALL LOCKABLE

STORAGE CABINETS WITH DOORS.

10. INSTALL TWO (2) 3'-0" WIDE X 2'-0" DEEP X 4'-8" TALL LOCKABLE

STORAGE CABINETS WITH DOORS.

11. INSTALL ENLARGED SEMI-PRIVATE OFFICE. SIMILAR TO DETAIL

4/I-500, EXCEPT 10'-0" WIDE X 20'-0" AND ADD (2) 3'-0" X 2'-0" X 7'-0"

TALL STORAGE CABINETS.

12. INSTALL A 6'-8" TALL SOLID PANEL WALL WITH 3'-0" X 6'-8" DOOR

FRAME AND HARDWARE.

KEYNOTES

GENERAL NOTES

1. THE GOVERNMENT WILL OCCUPY THE BUILDING DURING THIS

PROJECT. WORK SHALL BE COORDINATED WITH SITE POC AND

SHALL FOLLOW THE APPROVED PHASING PLAN.

2. CONTRACTOR SHALL PROTECT EXISTING SURFACES TO

REMAIN. PATCH, REPAIR OR REPLACE ANY DAMAGED

SURFACES.

3. INSTALL ELECTRICAL FOR FURNITURE AS PER APPROVED

SUBMITTAL.

4. INSTALL COMMUNICATION CABLING AS PER APPROVED

SUBMITTAL.. PROVIDE NEW COMMUNICATION CABLING TO

EXISTING OFFICES AND CONFERENCE ROOMS.

TYP

TYP

TYP

TYP

44 4 4 4

TYP

TYP

TYP

TYP

TYP

TYP

CONTINUED ON

DWG. I-103

TYP

PLAN

NORTH

TYP

OFFICE

1a

2a

3b

1b

3a

3c

B CA FD EA1

LOBBY

TELECOM/COMM

CORRIDOR

115A

MENS

WOMENS

VESTIBULE

OFFICE

OFFICE

VESTIBULE

OFFICE

OFFICE

OFFICE

CONFERENCE

WOMENS

PROJECTOR

STORAGE

MENS

SHEET

IDENTIFICATION

D

ES

IG

N

B Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

PL

O

T

SC

AL

E:

SI

ZE

AN

SI

D

C H

EC

KE

D B

Y:

PL

O

T D

AT

E:

FI

LE

N

AM

E:

SU

BM

IT

TA

L D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E:

AP

PR

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E:

AP

PR

B

C

D

1 2 3 4 5

1 2 3 4 5

Defense Information Systems Agency A Combat Support Agency

A

B

D

C

P.

O

.B O

X

G

R

EE

N W

O O

D V

IL

LA

G E

SE

L

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

.8

234567 14 13 12 11 10 9 8

* FOR OFFICIAL USE ONLY *

* FOR OFFICIAL USE ONLY *

I-103

A

C

EN

TE

R

S

AN

A N

TO

N

IO

FU

R N

IT

U

R E

AN

D

C

AR

PE

T

R

EP

LA

C

EM

EN

T

FU

R

N

IT

U R

E

FL

O O

R P

LA

N

AR

EA

C

- AK

S

AS

S

H O

W N

JE

S

- SA

T

- F U

R N

IT

U

R E

LA

YO

U T.

D W

G

N /A

N /A

N /A

0 8' 16' 24'

FURNITURE FLOOR PLAN - AREA C

SCALE : 1/8" = 1'-0"

KEY PLAN

SCALE: NTS

Date: 6 May 2021

A B

C D

1. INSTALL TYPICAL 6' X 6' CUBICLE, SEE TYPICAL DETAIL 1/I-500.

2. INSTALL TYPICAL 5'-0" CONSOLE, SEE TYPICAL DETAIL 1/I-500.

3. INSTALL TYPICAL 7'-6" CONSOLE, SEE TYPICAL DETAIL 4/I-500.

4. INSTALL TYPICAL SEMI-PRIVATE OFFICE, SEE DETAIL 4/I-500.

5. INSTALL TYPICAL TEAMING ROOM, SEE DETAIL 5/I-500.

6. INSTALL FULL HEIGHT DEMOUNTABLE PARTITION. COORDINATE

WITH EXISTING CEILING ITEMS TO COORDINATE FINAL LOCATION

WITH THE SITE POC.

7. INSTALL 3'-0" X 7'-0" DOOR, FRAME AND HARDWARE IN

DEMOUNTABLE PARTITION.

8. INSTALL PRINT AREA. PRINT AREA SHALL INCLUDE 6'-0" WIDE X

1'-6" DEEP WORK SURFACE WITH UNDER WORK SURFACE

STORAGE CABINETS WITH DOORS.

9. INSTALL TWO (2) 3'-0" WIDE X 1'-6" DEEP X 4'-8" TALL LOCKABLE

STORAGE CABINETS WITH DOORS.

10. INSTALL TWO (2) 3'-0" WIDE X 2'-0" DEEP X 4'-8" TALL LOCKABLE

STORAGE CABINETS WITH DOORS.

11. INSTALL ENLARGED SEMI-PRIVATE OFFICE. SIMILAR TO DETAIL

4/I-500, EXCEPT 10'-0" WIDE X 18'-0" AND ADD (2) 3'-0" X 2'-0" X 7'-0"

TALL STORAGE CABINETS.

12. INSTALL A 7'-0" TALL SOLID PANEL WALL WITH 3'-0" X 6'-8"

LOCKABLE DOOR, FRAME AND HARDWARE.

13. INSTALL FIVE (5) 3'-0" WIDE X 2'-0" DEEP X 5'-8" TALL LOCKABLE

STORAGE CABINETS WITH DOORS.

14. INSTALL 6'-0" STRAIGHT SECTION SIMILAR TO TYPICAL 6' X 6'

CUBICLE, SEE TYPICAL DETAIL 1/I-500.

15. INSTALL FURNITURE SIMILAR TO TYPICAL SEMI-PRIVATE OFFICE,

SEE DETAIL 4/I-500. WALL PANELS ACCEPTABLE IS REQUIRED.

KEYNOTES

GENERAL NOTES

1. THE GOVERNMENT WILL OCCUPY THE BUILDING DURING THIS

PROJECT. WORK SHALL BE COORDINATED WITH SITE POC AND

SHALL FOLLOW THE APPROVED PHASING PLAN.

2. CONTRACTOR SHALL PROTECT EXISTING SURFACES TO

REMAIN. PATCH, REPAIR OR REPLACE ANY DAMAGED

SURFACES.

3. INSTALL ELECTRICAL FOR FURNITURE AS PER APPROVED

SUBMITTAL.

4. INSTALL COMMUNICATION CABLING AS PER APPROVED

SUBMITTAL.. PROVIDE NEW COMMUNICATION CABLING TO

EXISTING OFFICES AND CONFERENCE ROOMS.

TYP

TYP

TYP

TYP

TYP

CONTINUED ON

DWG. I-102

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

CONFERENCE

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

CORRIDOR

130A

MENS

WOMENS

JANITOR

TELECOM/COMM

CONFERENCE

OPERATIONS

CORRIDOR

CONFERENCE

MECHANICAL ROOM

MECHANICAL ROOM

132MECHANICAL ROOM

5a

4a

5b

OPERATIONS

A-8

COMM

A-7

PROJECTOR

STORAGE

SHEET

IDENTIFICATION

D

ES

IG

N

B Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

PL

O

T

SC

AL

E:

SI

ZE

AN

SI

D

C H

EC

KE

D B

Y:

PL

O

T D

AT

E:

FI

LE

N

AM

E:

SU

BM

IT

TA

L D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E:

AP

PR

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E:

AP

PR

B

C

D

1 2 3 4 5

1 2 3 4 5

Defense Information Systems Agency A Combat Support Agency

A

B

D

C

P.

O

.B O

X

G

R

EE

N W

O O

D V

IL

LA

G E

SE

L

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

.8

234567 14 13 12 11 10 9 8

* FOR OFFICIAL USE ONLY *

* FOR OFFICIAL USE ONLY *

I-104

A

C

EN

TE

R

S

AN

A N

TO

N

IO

FU

R N

IT

U

R E

AN

D

C

AR

PE

T

R

EP

LA

C

EM

EN

T

C

AB

LE

T

R

AY

L

AY

O U

T

PL

AN

AR

EA

A

- AK

S

AS

S

H O

W N

JE

S

- SA

T

- F U

R N

IT

U

R E

LA

YO

U T.

D W

G

N /A

N /A

N /A

0 4' 8' 16'

CABLE TRAY LAYOUT PLAN - AREA A

SCALE : 1/8" = 1'-0"

KEY PLAN

SCALE: NTS

Date: 6 May 2021

A B

C D

1. INSTALL 12" WIDE X 2" DEEP CABLE TRAY. PROVIDE WATER FALLS

AT EACH CABLE DROPS. PROVIDE MINIMUM 3'-0" SEPARATION

BETWEEN PARALLEL CABLE TRAYS RUNS.

2. EXTEND CABLE TRAY TO EXISTING COMM RACK (VERIFY

LOCATION) AND PROVIDE WATER FALLS DOWN TO EXISTING COMM

RACK.

3. PROVIDE MINIMUM OF 6" SEPARATION AT ALL INTERSECTIONS.

KEYNOTES

GENERAL NOTES

1. THE GOVERNMENT WILL OCCUPY THE BUILDING DURING THIS

PROJECT. WORK SHALL BE COORDINATED WITH SITE POC AND

SHALL FOLLOW THE APPROVED PHASING PLAN.

2. CONTRACTOR SHALL PROTECT EXISTING SURFACES TO

REMAIN. PATCH, REPAIR OR REPLACE ANY DAMAGED

SURFACES.

3. INSTALL ELECTRICAL FOR FURNITURE AS PER APPROVED

SUBMITTAL.

4. INSTALL COMMUNICATION CABLING AS PER APPROVED

SUBMITTAL. PROVIDE NEW COMMUNICATION CABLING TO

EXISTING OFFICES AND CONFERENCE ROOMS.

5. INSTALL CABLE TRAY MEETING DISA SPECIFICATION. CABLE

TRAY SHALL BE 12" WIDE X 2" DEEP AND BE SUPPORTED FROM

ROOF STRUCTURE ABOVE. PROVIDE STAMPED AND SIGNED

STRUCTURAL ENGINEER'S CALCULATIONS AND DETAILS.

CONTINUED ON

DWG. I-103

TYP

TYP

TYP

TYP

TYP

TYP

TYP

TYP

TYP

TYP

2' -5

7' -0

TYPICAL SERVICE PANEL WITH TACKABLE

ACOUSTICAL PANEL, SLAT WALL, AND 16"

FRAMELESS GLASS PANEL

POWER AT BASE LINE, TYPICAL

DATA AT BASE LINE, TYPICAL

FLOOR LEVELERS, TYPICAL

POWER DISTRIBUTION STRIP, ATTACH

TO UNDERSIDE OF WORK SURFACE, TYPICAL

MOBILE PEDESTAL (BOX/BOX/FILE) WITH GUEST SEATING

TASK CHAIR

PLASTIC LAMINATE WORK SURFACE WITH

OPENINGS OR GROMMETS FOR CABLES, TYPICAL

6'-0"

6' -0

TYPICAL WALL PANEL

POWER AT BELT LINE, TYPICAL

END PANEL, NOT SHOWN FOR CLARITY

2' -5

4' -8

36" WIDE MAGNETIC WHITE BOARD

WORK SURFACE WITH GROMMETS OR

OPENING FOR CABLES, TYPICAL

FLOOR LEVELERS, TYPICAL

15" WIDE MOBILE PEDESTAL (BOX/BOX/FILE)

WITH GUEST SEATING

END PANEL

TYPICAL WALL PANEL WITH TACKABLE

ACOUSTICAL PANELS, UNLESS NOTED

OTHERWISE, TYPICAL

TYPICAL WALL PANEL

4' -8

1'

-0

12" TALL FRAMED GLASS PANEL

(2) TWO 36" WIDE MAGNETIC WHITE BOARDS

1' -4

1'

-0

1' -4

16" TALL FRAMELESS GLASS PANEL

12" TALL FRAMED GLASS PANEL, TYPICAL

16" TALL FRAMELESS GLASS PANEL, TYPICAL

(2) SINGLE MONITOR ARMS, SLAT

WALL MOUNTED, TYPICAL

MOBILE PEDESTAL (FILE/FILE)

TYPICAL SERVICE PANEL - SEE ELEVATIONS

(2) SINGLE MONITOR ARMS, SLAT

WALL MOUNTED, TYPICAL

TYPICAL WALL PANEL - SEE ELEVATIONS BELOW

NOTE: SOLID PANELS SHALL BE TACK-ABLE ACOUSTICAL

PANELS, UNLESS NOTED OTHERWISE, TYPICAL

DATA PORT AT BELT LINE, TYPICAL

TYPICAL SERVICE PANEL (SOLID) SHALL HAVE

MINIMUM OF 3 DATA/COMM RACEWAYS,

TYPICAL

TYPICAL SERVICE PANEL (SOLID) SHALL HAVE

MINIMUM OF 3 DATA/COMM RACEWAYS,

TYPICAL

16" HIGH SLAT WALL

16" TALL SLAT WALL, TYPICAL

(2) TWO SINGLE MONITOR ARMS, SLAT WALL

MOUNTED

EXISTING SUSPENDED CEILING AND LIGHTS - VERIFY

TYPICAL SERVICE PANEL (SOLID) SHALL HAVE

MINIMUM OF 3 DATA/COMM RACEWAYS,

TYPICAL

EXISTING SUSPENDED CEILING AND

LIGHTS - VERIFY

MOBILE PEDESTAL (FILE/FILE)

CABLE MANAGEMENT SYSTEM, TYPICAL

CABLE MANAGEMENT SYSTEM, TYPICAL

WORK SURFACE WITH GROMMETS OR

OPENING FOR CABLES, TYPICAL

OVERHEAD STORAGE WITH DOORS WITH

UNDER CABINET LIGHTING

12'-0"

'-0

" 60

60246624

FF

FF

BF

36" WIDE 2 DRAWER LATERAL FILE

TASK CHAIR

60" X 30" MOBILE PLASTIC LAMINATE WORK SURFACE

42" WIDE SLIDING OR 36" SWINGING DOOR

WITH PANEL (BRACE) AND GLASS PANEL

ABOVE DOOR OPENING

(2) SIDE CHAIRS

(2) TWO SINGLE SLAT WALL MOUNTED MONITOR ARMS

MOBILE PEDESTAL (FILE/FILE)

PLASTIC LAMINATE WORK SURFACE WITH

OPENINGS FOR CABLES, TYPICAL

TYPICAL SERVICE PANEL WALL, 5'-8" TALL SOLID TACK-ABLE

ACOUSTICAL PANELS (UNLESS NOTED OTHERWISE) WITH 16"

FRAMELESS GLASS TOPPER. MAXIMUM TOTAL PANEL HEIGHT

SHALL NOT EXCEED 7'-0".

36" X 48" MAGNETIC WHITE BOARD, TYPICAL

MOBILE PEDESTAL (BOX/BOX/FILE)

TYPICAL SERVICE PANEL WALL, 5'-8" TALL SOLID TACK-ABLE

ACOUSTICAL PANELS (UNLESS NOTED OTHERWISE) WITH 16"

FRAMELESS GLASS TOPPER. MAXIMUM TOTAL PANEL HEIGHT

SHALL NOT EXCEED 7'-0".

PROVIDE 60" X 16" SLAT WALL

(8) EIGHT TASK CHAIR

10'-0" X 2'-6" BOAT SHAPED CONFERENCE TABLE

TYPICAL SERVICE PANEL WALL, 68" TALL SOLID TACK-ABLE

ACOUSTICAL PANELS (UNLESS NOTED OTHERWISE) WITH 16"

FRAMELESS GLASS TOPPER. MAXIMUM TOTAL PANEL HEIGHT

SHALL NOT EXCEED 7'-0".

10'-0" X 4'-0" MAGNETIC WHITE BOARD, TYPICAL

TYPICAL SERVICE PANEL WALL, 5'-8" TALL SOLID TACK-ABLE

ACOUSTICAL PANELS (UNLESS NOTED OTHERWISE) WITH 16"

FRAMELESS GLASS TOPPER. MAXIMUM TOTAL PANEL HEIGHT

SHALL NOT EXCEED 7'-0".

16" FRAMELESS GLASS TOPPER TYPICAL

42" WIDE SLIDING OR 36" SWINGING DOOR

WITH PANEL (BRACE) AND GLASS PANEL

ABOVE DOOR OPENING

DUPLEX POWER OUTLET @ BASE

( INDICATES ABOVE WORK SURFACE)

TWO (2) RJ45 CONNECTORS FOR COPPER

( INDICATES ABOVE WORK SURFACE)

TWO (2) LC CONNECTORS FOR FIBER

( INDICATES ABOVE WORK SURFACE)

TYPICAL LEGEND

'-0

14'-0"

PROVIDE SOLID PANEL AS REQUIRED FOR

DOOR

PROVIDE SOLID PANEL AS REQUIRED FOR

DOOR

SHEET

IDENTIFICATION

D

ES

IG

N

B Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

PL

O

T

SC

AL

E:

SI

ZE

AN

SI

D

C H

EC

KE

D B

Y:

PL

O

T D

AT

E:

FI

LE

N

AM

E:

SU

BM

IT

TA

L D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E:

AP

PR

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E:

AP

PR

B

C

D

1 2 3 4 5

1 2 3 4 5

Defense Information Systems Agency A Combat Support Agency

A

B

D

C

P.

O

.B O

X

G

R

EE

N W

O O

D V

IL

LA

G E

SE

L

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

.8

* FOR OFFICIAL USE ONLY *

* FOR OFFICIAL USE ONLY *

A

AK

S

AS

S

H O

W N

IN

IT

IA

LS

/0

4/

SA

T

FU

R

N

IT

U R

E

- I

-5

D

ET

AI

LS

.D W

G

N /A

N /A

N /A

5/ 4/

I-500

D at a C en te r O gd en , H ill

AF

B, U

T Fu rn itu re a nd C ar pe t R ep la ce m en t P ro je ct

Fu rn itu re

E nl ar ge d Pl an s an d

D et ai ls

I-500

TYPICAL 6'-0" X 6'-0" CUBICLE

SCALE : 3/8"= 1'-0" 0 2' 4' 6'

I-500

ELEVATION TYPICAL 6'-0" X 6'-0" CUBICLE

SCALE : 3/8"= 1'-0" 0 2' 4' 6'

I-500

ELEVATION TYPICAL 6'-0" X 6'-0" CUBICLE

SCALE : 3/8"= 1'-0" 0 2' 4' 6'

I-500

TYPICAL TEAMING ROOM

SCALE : 3/8"= 1'-0" 0 2' 4' 6'

I-500

TYPICAL SEMI-PRIVATE OFFICE

SCALE : 3/8"= 1'-0" 0 2' 4' 6'

2' -5

4' -8

(2) SINGLE MONITOR ARMS, SLAT

WALL MOUNTED

WORK SURFACE WITH OPENING

FOR CABLES, TYPICAL

POWER AT BELT LINE, TYPICAL

DATA AT BASE LINE, TYPICAL

FLOOR LEVELERS, TYPICAL

POWER DISTRIBUTION STRIP, ATTACH

TO UNDERSIDE OF WORK SURFACE,

TYPICAL

POWER AT BELT LINE, TYPICAL

TYPICAL SPLINE WALL PANEL

WALL PANEL WITH TACKABLE ACOUSTICAL

PANELS UNLESS NOTED OTHERWISE, TYPICAL

5'-0"

DUPLEX POWER OUTLET @ BASE

( INDICATES ABOVE WORK SURFACE)

TWO (2) RJ45 CONNECTORS FOR COPPER

( INDICATES ABOVE WORK SURFACE)

TWO (2) LC CONNECTORS FOR FIBER

( INDICATES ABOVE WORK SURFACE)

TYPICAL LEGEND

TASK CHAIR

PLASTIC LAMINATE WORK SURFACE WITH

OPENINGS FOR CABLES, TYPICAL

TYPICAL

3' -0

TY

PI

C

AL

16" HIGH SLAT WALL PANEL, TYPICAL

(3) SINGLE MONITOR ARMS, SLAT

WALL MOUNTED

1' -4

FRAMELESS GLASS PANEL, TYPICAL.

WALL PANEL WITH TACKABLE ACOUSTICAL

PANELS UNLESS NOTED OTHERWISE, TYPICAL

16" FRAMELESS GLASS PANEL, TYPICAL.

SPLINE WALL PANEL WITH TACKABLE ACOUSTICAL

PANELS UNLESS NOTED OTHERWISE, TYPICAL

SOLID PANEL SPLINE WALL SHALL HAVE

MINIMUM OF 3 DATA/COMM RACEWAYS,

TYPICAL

DATA PORTS AT BELT LINE, TYPICAL

7' -0

1' -0

7'-6"

TYPICAL

3' -0

TY

PI

C

AL

TASK CHAIR

PLASTIC LAMINATE WORK SURFACE WITH

OPENINGS FOR CABLES, TYPICAL

(3) SINGLE MONITOR ARMS, SLAT

WALL MOUNTED

WALL PANEL WITH TACKABLE ACOUSTICAL

PANELS UNLESS NOTED OTHERWISE, TYPICAL

16" FRAMELESS GLASS PANEL, TYPICAL.

SPLINE WALL PANEL WITH TACKABLE ACOUSTICAL

PANELS UNLESS NOTED OTHERWISE, TYPICAL

2' -5

4' -8

(2) SINGLE MONITOR ARMS, SLAT

WALL MOUNTED

WORK SURFACE WITH OPENING

FOR CABLES, TYPICAL

POWER AT BELT LINE, TYPICAL

DATA AT BASE LINE, TYPICAL

FLOOR LEVELERS, TYPICAL

POWER DISTRIBUTION STRIP, ATTACH

TO UNDERSIDE OF WORK SURFACE,

TYPICAL

POWER AT BELT LINE, TYPICAL

TYPICAL SPLINE WALL PANEL

WALL PANEL WITH TACKABLE ACOUSTICAL

PANELS UNLESS NOTED OTHERWISE, TYPICAL

16" HIGH SLAT WALL PANEL, TYPICAL1'

-4

FRAMELESS GLASS PANEL, TYPICAL.

SOLID PANEL SPLINE WALL SHALL HAVE

MINIMUM OF 3 DATA/COMM RACEWAYS,

TYPICAL

DATA PORTS AT BELT LINE, TYPICAL

7' -0

1' -0

I-500

TYPICAL 5'-0" CONSOLE - PLAN

SCALE : 3/8"= 1'-0" 0 4' 8' 12'

I-500

TYPICAL 5'-0" CONSOLE - ELEVATION

SCALE : 3/8"= 1'-0" 0 4' 8' 12'

I-500

TYPICAL 7'-6" CONSOLE - PLAN

SCALE : 3/8"= 1'-0" 0 4' 8' 12'

I-500

TYPICAL 7'-6" CONSOLE - ELEVATION

SCALE : 3/8"= 1'-0" 0 4' 8' 12'

9 7

SHEET

IDENTIFICATION

D

ES

IG

N

B Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

PL

O

T

SC

AL

E:

SI

ZE

AN

SI

D

C H

EC

KE

D B

Y:

PL

O

T D

AT

E:

FI

LE

N

AM

E:

SU

BM

IT

TA

L D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E:

AP

PR

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E:

AP

PR

B

C

D

1 2 3 4 5

1 2 3 4 5

Defense Information Systems Agency A Combat Support Agency

A

B

D

C

P.

O

.B O

X

G

R

EE

N W

O O

D V

IL

LA

G E

SE

L

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

.8

* FOR OFFICIAL USE ONLY *

* FOR OFFICIAL USE ONLY *

A

AK

S

AS

S

H O

W N

IN

IT

IA

LS

/0

4/

SA

T

FU

R

N

IT

U R

E

- I

-5

D

ET

AI

LS

.D W

G

N /A

N /A

N /A

5/ 4/

I-501

D at a C en te r O gd en , H ill

AF

B, U

T Fu rn itu re a nd C ar pe t R ep la ce m en t P ro je ct

Fu rn itu re

E nl ar ge d Pl an s an d

D et ai ls

Sheets and Views
COVER SHEET
SAT G-002.pdf
Sheets and Views
G-002
SAT ID-100.pdf
Sheets and Views
ID-100
SAT ID-101.pdf
Sheets and Views
ID-101
SAT I-100.pdf
Sheets and Views
I-100
SAT I-101.pdf
Sheets and Views
I-101
SAT I-102.pdf
Sheets and Views
I-102
SAT I-103.pdf
Sheets and Views
I-103
SAT I-104.pdf
Sheets and Views
I-104
SAT I-500.pdf
Sheets and Views
I-500
SAT I-501.pdf
Sheets and Views
I-501
SAT - Furniture Layout-I-102.pdf
Sheets and Views
I-102

File details come from the government source that posted it. Updated .