Response_to_Questions.pdf

PDF 90 KB Posted

Attached to
Computed Radiography Imaging System
Solicitation number
FA8517-17-R-0003
Issued by

About this file

Response to Questions

View the file

Other files

File Type Posted
FA8517-17-R-0003-0002.pdf PDF
Response_to_Questions_Post__2__15_June_2017.pdf PDF
Response_to_Questions_Posted_15_June_2017.pdf PDF
Response_to_Questions_Posted_14_June_2017.pdf PDF
Questions_12_Juen_2017.pdf PDF
FA8517-17-R-0003-0001.pdf PDF
Transportation_Form_1653.pdf PDF
FA8517-17-R-0003.pdf PDF
CDRL_A001-A004.pdf PDF
TM-86-01P.pdf PDF
Technical_Manual_33B-1-2_Appendix_1.pdf PDF
AFMC_Form_158.pdf PDF
Appendix_2.pdf PDF
Product_Description_PD-AFLCMC-EZPT-17-01.pdf PDF
Appendix_3.pdf PDF
CDRL_A005-A006.pdf PDF
CDRL_A007.pdf PDF
Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Question 1:

We cannot find these documents listed in RFP FA8517‐17‐R‐0003 and PD‐AFLCMC‐EZPT‐17‐01?

DI‐TMSS‐80527A

http://quicksearch.dla.mil/qsDocDetails.aspx?ident_number=204698

DI‐MISC‐80557

http://quicksearch.dla.mil/qsDocDetails.aspx?ident_number=205093 M‐900 Evaluation Basis of Award Reference RFP page 47 of 48

2. Proposal Evaluation. The evaluation process will be accomplished as follows.

A) Technical Factor.

1. General: The written technical proposal shall be clear, concise, and include all the information required by this provision in sufficient detail for effective evaluation. The proposal should not simply rephrase or restate the Government’s requirements, but rather shall provide convincing rationale to address how the offeror intends to meet these requirements. Offerors shall assume the Government has no prior knowledge of their capabilities, work processes, facilities, and experience and will base its evaluation on the information presented in the offeror’s technical proposal.

2. Format and Specific Content: The following information shall be provided in the written technical proposal and will be evaluated to assess technical acceptability in accordance with Section M-900, Evaluation Basis for Award. The written technical proposal shall address the following subfactor to describe the offeror’s approach to performing the requirements set forth in Purchase Description PD-AFLCMC-EZPT- 17-01.

Subfactor One: The offeror’s technical proposal shall provide a single specification sheet or multiple specification sheets to demonstrate the offeror’s proposed item shall meet the following PD paragraphs:

2.1 5.1.2.2 5.2.2 5.2.2.3 5.2.2.5 5.3.1.1.1 5.4.4.7 5.6 5.9.1.3 5.9.1.4 5.9.1.5 6.5

Please provide above documents, or advise where to find them.

Question 2:

Is Offeror required to respond to each Paragraph in PD‐AFLCMC‐EZPT‐17‐01 or address PD‐AFLCMC‐ EZPT‐17‐01 paragraphs listed in RFP FA8517‐17‐R‐0003?

Must specifically address requirements of paragraphs:

2.1 5.1.2.2 5.2.2 5.2.2.3 5.2.2.5 5.3.1.1.1 5.4.4.7 5.6 5.9.1.3 5.9.1.4 5.9.1.5 6.5

Question #3:

Do we need to include a shipping/transport case for the Large Format Printer? If so, does the shipping/transport case for the Large Format Printer need to meets and/or exceeds all the MIL STD’s that are required for the core CR system (MIL‐STD‐810G, MIL‐PRF‐28800F, etc.)?

Yes, printer must be able to deploy with system. However, size and weight restrictions of PD paragraph 5.1.3 do not apply to the printer.

Question 4:

If CR system offering for RFP FA8517‐17‐R‐0003 has been approved by USAF Performance requirements per paragraph below, can offeror address appropriate PD paragraphs (also listed below) with statement “requirement met with USAF CR System approval”?

No, “The proposal should not simply rephrase or restate the Government’s requirements, but rather shall provide convincing rationale to address how the offeror intends to meet these requirements.” but may reference government test results.

Question 5:

Can USAF waive requirement to send USAF CDRL 0004 ELIN A002 Radiographic Process Control Images as these images were required as part of USAF CR system approval. Offeror can note “CDRL 004 ELIN A002 Radiographic Process Control Images previously approved per USAF CR system approval” No, the radiographic image is a final OEM quality check of the system as delivered, and will be used as a baseline to determine future system performance. It is serialized by both CR system and CR process control device.

File details come from the government source that posted it. Updated .