RFI_-RFC_FORM_20150420_0004.pdf

PDF 106 KB Posted

Attached to
B1651 Renovate Building Federal contract opportunity
Solicitation number
FA6675-15-R-0004
Issued by
Department of the Air Force Reserve Command

About this file

RFI

View the file

Other files for this federal contract opportunity

Other files attached to B1651 Renovate Building, newest first.
File Type Posted
1651_-_RFI_No._4_-_Lighting__Electrical.pdf PDF
1651_-_RFI_No._4_-_Lighting_ _Electrical.pdf PDF
1651_-_Design_RFI.pdf PDF
FA6675-15-R-0004-0003.doc DOC document
RFI's_1 2 3_FA6675-15-R-0004-signed.pdf PDF
FA6675-15-R-0004-0002.pdf PDF
FA6675-15-R-0004-00001.pdf PDF
Binder1_Specifications_Div_001_DDPM_14-0002.pdf PDF
2015.03.13_Final_Specifications.pdf PDF
2015-03-11_FINAL_DRAWINGS.pdf PDF
RFI_-RFC_FORM_20150420.doc DOC document
FA6675-15-R-0004_B1651_Renovate_Building.pdf PDF
DBA_WD_TX150322_20150306_TX322.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR INFORMATION / CLARIFICATION FORM

FOR CONTRACTOR USE ONLY

CONTRACT NO:

RFI NO: 0004 DATE (YYYYMMDD)

20150810

SUBJECT:

Solicitation FA6675-15-R-0004

DRAWING REFERENCE/ DETAIL:

ATTACHMENT SENT UNDER SEPARATE

COVER(__)

RESPONSE NEEDED BY:

ASAP

REQUEST:

Referencing solicitation page 44 of 47, paragraph 2.b. The requirement for Project Managers and Superintendents is to have “at least three (3) recent projects of similar scope and size, from award through project completion within the past three years.” We believe it is unrealistic to expect a person to have three projects, up to $5 million, completed from cradle-to-grave in a three-year period.

PROPOSED SOLUTION (If applicable:

For the PM and superintendents, expand the period of performance from 3 years to at least 5 years, preferably 7. Alternatively, reduce the number of projects to “at least one”.

TO(Contracting Officer): 301 CONF/LGC

FROM (Contractor):

Dakota Meyer Enterprises, Inc.

DATE (YYYYMMDD)

20150810

TYPE OR PRINT NAME AND TITLE

John P. Feiler, Technical Writer

SIGNATURE:

//SIGNED//

FOR GOVERNMENT USE ONLY

FROM CONTRACTING

TO:(Base Civil Engineering): Charles Tehan (__) Robert Dudley(__)

For Evaluation and Action

DATE (YYYYMMDD) TYPE OR PRINT NAME AND TITLE SIGNATURE:

RFI RESPONSE / CLARIFICATION (refer to page 2)

REQUEST FOR INFORMATION / CLARIFICATION FORM

RFI RESPONSE / CLARIFICATION:-

Government to complete following sections:

Page 44 paragraph 2.b.(Table 1 – Personnel Qualification)was updated. See Amendment #3.

Table 1 – Personnel Qualifications Position Experience Standard Documentation Req’d

Project Manager Managing or supervising at least two (2) recent projects of similar scope and size, from award through project completion within the past five years.

References/Resume

Superintendent Experience as a superintendent on at least two (2) recent projects of similar scope and size, from award through project completion within the past five years.

References/Resume

Construction Quality Control Manager

Documentation of quality assurance training ≥ three (3) years experience. References/Resume

TO:(AF Contractiing Office)

TO:(Contractor)

CONTRACTOR REVIEW

After reviewing the Government response, does the contractor anticipate A change order will be required? YES NO There will be an increase in the cost of the project? YES NO

Reviewer:

*Contractor- return reviewed form to Contracting Officer. Should the review results in YES for either of the two questions, if any further action is required by the contractor (i.e. submission of change proporsal), they will be notified by the contracting office.

1128532044C Typewritten Text 20150813

1128532044C Typewritten Text Nelson Kraemer

1128532044C Approved

File details come from the government source that posted it. Updated .