N.T.S.

FINAL DESIGN

VICINITY MAP

5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779

www.avconinc.com

OFFICE: (407) 599-1122 - FAX: (407) 599-1133

12/04/2015

Sheet List Table

Sheet Number Sheet Title

North

L O C A T I O N M A P

DESIGN DRAWINGS FOR:

HOMESTEAD AIR RESERVE BASE, FLORIDA

INTERIOR RENOVATIONS TO

BUILDING 874

W9127810D0118

N.T.S.

ENGINEER:

CLIENT:

PROJECT LOCATION

PROJECT LOCATION

HOMESTEAD, FLORIDA

ENGINEERS & PLANNERS

AVCON, INC.

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

CONSTRUCTION IN THE PROJECT AREA.

AS-BUILT DRAWINGS

BRIEFING RM 2

BRIEFING RM 1

MAINTENANCE

215A

COMM CLOSET

PILOT AREA

HALL 2

HALL 1

SHEET

Sheet of

SCALE: 1/4" = 1'-0"

1 2' 0 2' 4'

EXIT ACCESS TRAVEL DISTANCEXXX'

LOCATION OF EXIT SIGNS

(COORDINATE W/

ELECTRICAL DRAWINGS)

RECESSED FIRE EXTINGUISHER

CABINET. WRAP HOUSING WITH

INSULATION TO ENSURE STC

RATING IS MET.

TO SECOND MEANS OF EGRESS

LIFE SAFETY PLAN

SYMBOLS LEGEND

FE

OCCUPANT LOAD - RENOVATED AREA9

1 HOUR FIRE RATED WALL

DRAWING NO.

SYMBOLS LEGEND

SHEET NO.

DRAWING NO.

DRAWING TITLE

SECTION SYMBOL 1234

ROOM NUMBER

WINDOW TYPE

SPOT ELEVATION

DOOR NUMBER

ELEVATION SYMBOL

KEY NOTE

A-400

BUILDING AREA

NET HEATED AND COOLED: 865 SQUARE FEET

DRAWING

SCALE: 1/8" = 1'-0"

OCCUPANCY LOAD

EXTEND WALL TO UNDERSIDE

OF DECKING; SEAL ALL

PENTRATIONS WITH FIRE CAULK

DEMOLITION PLAN

SCALE: 1/4" = 1'-0"

2 2' 0 2' 4'

DEMOLITION KEY NOTES

DEMOLISH EXISTING WALLS, DOORS AND DOOR FRAMES.

DEMOLISH EXISTING WINDOWS AND FRAMES.

DEMOLISH EXISTING DOOR AND FRAME.

DEMOLISH PORTION OF WALL TO ACCOMMODATE NEW DOOR AND

FRAME.

REMOVE ALL EXISTING CARPET, CEILING AND BASE BOARD FINISHES.

EXISTING PORTION OF RAISED FLOOR TO BE DEMOLISHED.

REMOVE GYPBPARD ON INTERIOR SIDE OF WALL TO ACCOMMODATE

NEW ELECTRICAL AND SOUND RATING REQUIREMENTS.

D1

D2

D3

D1D1D1

D2 D2

D4

CONTRACTOR TO VERIFY ALL EXISTING

CONDITIONS AND DIMENSIONS PRIOR TO FINAL

ACCEPTANCE OF DESIGN DOCUMENTS.

D5

D5 D5

LIFE SAFETY PLAN

LIFE SAFETY KEY NOTES

EXISTING FIRE EXTINGUISHER CABINET IN THIS VICINITY TO REMAIN IN

CURRENT LOCATION.

L1

D5 D5

D5 D5D5

D3

D3

D4

D4

D3D3

D3

36'

L1

FE

D6

D6

D7

D7 D7

D7 D7

D7 D7

D7

A1.01

BRIEFING RM 2

BRIEFING RM 1

MAINTENANCE

215A

COMM CLOSET

PILOT AREA

HALL 2

HALL 1

E

XI

S

TI

N G

0'

-0

E

XI

S

TI

N G

0'

-0

'-0

5'

-4

EXISTING 11'-2"

5' -1

0"

EXISTING 4'-6" EXISTING 11'-10"

13'-10"

REFLECTED CEILING PLAN

SCALE: 1/4" = 1'-0"

1 2' 0 2' 4'

SHEET

Sheet of

FLOOR PLAN

SCALE: 1/4" = 1'-0"

2 2' 0 2' 4'

REFLECTED CEILING KEY NOTES

2'X2' FLOURESCENT LIGHT FIXTURES. SEE ELECTRICAL PLANS.

4' FLOURESCENT UTILITY FIXTURE. SEE ELECTRICAL PLANS.

2'X2' ACOUSTICAL CEILING TILE. USG MARS ClimaPlus - HIGH NRC OR

EQUAL.

PROVIDE DUPLEX OUTLET AND DATA DROP FOR CEILING MOUNTED

PROJECTOR. SEE ELECTRICAL PLANS.

ALL EXISTING SPRINKLER HEADS AND FIRE ALARM EQUIPMENT SHALL BE

RELOCATED AND/OR ADDED TO ACCOMOMDATE NEW LAYOUT.

SPRINKLERS AND ALARMS SHALL BE CENTERED ON CEILING TILES. SEE

ELECTRICAL AND FIRE PROTECTION PLANS.

R1

ARCHITECTURAL KEY NOTES

EXISTING PERIMETER WALL TO REMAIN. SEE WALL DETAIL 4/A1.10.

NEW 35

8" METAL STUD WALL TO EXTEND TO UNDERSIDE OF DECK. 1

LAYER OF 5 8" GYPBOARD ON EXTERIOR SIDE OF WALL, 2 LAYERS OF 5

8"

GYPBOARD w/ STAGGERED JOINTS ON THE INTERIOR SIDE OF THE WALL.

GYP BOARD TO EXTEND TO UNDERSIDE OF DECK WITH ACOUSTICAL

SEALANT AT TOP AND BOTTOM. SOUND ATTENUATION INSULATION

WITHIN NEW STUD CAVITY TO EXTEND TO UNDERSIDE OF DECK. SEE

WALL DETAIL 4/A1.10. PROVIDE STC 45 RATING FOR WALL.

NEW 3 5 8" METAL STUD WALL TO EXTEND TO UNDERSIDE OF DECK. 1

LAYER OF 5 8" GYPBOARD ON ONE SIDE OF WALL, 2 LAYERS OF 5

8" GYPBOARD ON OTHER w/ STAGGERED JOINTS . SOUND ATTENUATION

INSULATION WITHIN NEW STUD CAVITY TO EXTEND TO UNDERSIDE OF

DECK. SEE WALL DETAIL 1/A1.10. PROVIDE STC 45 RATING FOR WALL.

4" CORE DRILLED CHASE, ENCLOSED w/ 6" METAL STUD FRAMING AND 1

LAYER OF 5 8" GYP BOARD.

A1

A2

A3

CONTRACTOR TO VERIFY ALL EXISTING

CONDITIONS AND DIMENSIONS PRIOR TO FINAL

ACCEPTANCE OF DESIGN DOCUMENTS.

A1

A1

A1

A2

A2

A2

A2A2

A3

NEW 6" METAL STUD WALL w/ STUDS @ 16" O.C. TO EXTEND TO UNDERSIDE

OF DECK; 1 LAYER OF 5 8" GYPBOARD ON EXTERIOR SIDE OF WALL, 2

LAYERS OF 5 8" GYPBOARD w/ STAGGERED JOINTS w/ SOUND ATTENUATION INSULATION. JAMB STUDS FOR DOORS SHALL BE DOUBLED 16ga.& HORIZONTALLY BRACED WITH 16ga. METAL STUDS. IF ADJOINING WALLS

ARE FIRE RATED, RATING MUST BE CARRIED THROUGHOUT NEW WALL AND

DOOR. SEE WALL DETAIL 2/A1.10. PROVIDE STC 45 RATING FOR WALL.

INFILL EXTERIOR PLANE OF EXISTING WINDOW OPENING WITH MASONRY

MATCHING EXISTING EXTERIOR. MASONRY SHALL LINE UP w/ EXISTING PLANE. INTERIOR WALL SHALL RECEIVE 6" METAL STUD WALL w/ BATT INSULATOIN w/ 2 LAYERS OF 5 8" GYP BOARD AND SHALL LINE UP WITH

EXISTING SURROUNDING WALL PLANE. SEE WALL DETAIL 5/A1.10.

EXTEND EXISTING STUD WALL TO UNDERSIDE OF DECK w/ SOUND

ATTENUATION INSULATION AND 1 LAYER OF 5 8" GYPBOARD ON ONE SIDE

OF WALL, 2 LAYERS OF 5 8" GYPBOARD ON OTHER w/ STAGGERED JOINTS SEE WALL DETAIL 3/A1.10. REINFORCE DOOR JAMBS w/ 3 5

8"16ga NO-HOLE

STEEL STUDS. PROVIDE STC 45 RATING FOR WALL.

NEW 21 DOOR CELL PHONE LOCKER w/ MASTER ACCESS; MAILBOX WORKS

- 7X3 - 21 DOOR CELL PONE LOCKER (AFH1600XD73)

A5

A5

A5

A5

3'-0" x 7'-0"

SOUND

RATING

FRAME

MAT'L REMARKSJAMBHEADHDW SILLMAT'LSIZE TYPENO.

DOOR SCHEDULE

DOOR

3'-0" x 7'-0"

3'-0" x 7'-0"

3'-0" x 7'-0"

3'-0" x 7'-0"

3'-0" x 7'-0"102

3'-0" x 7'-0"101 C MTL HMHW-1

B WD

B WD

B WD

B WD

C MTL

A WD

HM

HM

HM

HM

HM

HM

7/A1.10 8/A1.10 9/A1.10

HW-2

HW-2

HW-3

HW-1

HW-3

HW-4

A6

A6 A6

- INTERIOR LATEX PAINTPNT

- 5/8" GYP BOARD; PRIMED & PAINTEDGYP

MTL - METAL DOOR; SEE SCHEDULE; PRIMED & PAINTED

DOORS

" TYPE "X" GYPSUM BOARD85-

CAR1 - COMMERCIAL GRADE CARPET TILE

GB

RB - 4" RESILIENT WALL BASE

CEILINGS

WALLS

BASE

FLOORING

ABBREVIATIONS

- LAY-IN ACOUSTICAL CEILING TILE 2'x2'-WHITEACT1

HM - HOLLOW METAL FRAME - WELDED

1 3/4" WOOD DOOR

TYPE B

w/ 45 STC RATING;

SOLID CORE BIRCH

TYPE A

1 3/4" WOOD DOOR

DOOR TYPES

SOLID CORE BIRCH

RB ACT1

REMARKSBASE

PNT

MAINTENANCE218

217 BRIEFING ROOM 1

GBCAR1

BRIEFING ROOM 2

COMM CLOSET

WALL

MAT'L HTFINISHFLOORNO.

215A

215 PILOT AREA

CEILING

FINISHROOM NAME

FINISH SCHEDULE

RBPNTGBSC

CAR1

CAR1

CAR1

RBPNTGB

RBPNTGB

RBPNTGB

ACT1

ACT1

8'-0"

EXPOSED

219 HALL 1

HALL 2

- EXPOSED CEILINGEXP

+ 8'-0" A.F.F.

EXPOSED

+ 8'-0" A.F.F.

+ 8'-0" A.F.F.

+ 8'-0" A.F.F.

+ 8'-0" A.F.F.

+ 8'-0" A.F.F.

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

ACT1

ACT1

ACT1

RB

RB

PNT

PNT

GB

GB

CAR1

CAR1

SOUND BATTS OVER ACT CEILING

SOUND BATTS OVER ACT CEILING

A7 A7

A7

A7

A7

A7

A1

R1

R1 R1

R1 R1

R1 R1

R1

R1

R1

R1

R1R1

R1

R1

R1

R1R1

R1R1

R1

R1 R1 R1

R1R1R1

R2

R2R2

R3

R3

R3

R3

R3

R3 R3

R3 R4

R4

R5

R5

R5

R5

R5

R5 R5

R5

A8

A8

HARDWARE SCHEDULE

HW-1

HW-2

HW-3

HW-4

A4

A4

FIELD RATED

PRE-CUT DOOR FOR CIPHER LOCK

WD - SOLID CORE WOOD DOOR; SEE SCHEDULE

STAINED TO MATCH EXISTING - RFI-0004

TYPE C

w/ 45 STC RATING;

METAL DOOR

FIELD RATED

7/A1.10 8/A1.10 9/A1.10

7/A1.10 8/A1.10 9/A1.10

7/A1.10 8/A1.10 9/A1.10

7/A1.10 8/A1.10 9/A1.10

7/A1.10 8/A1.10 9/A1.10

7/A1.10 8/A1.10 9/A1.10

STC 45

STC 45

STC 45

STC 45

STC 45

STC 45

STC 45

X-10 LOCKSET, BALANCED MAGNETIC SWITCH, LEVER

SET, ALARMED, NON-HOLD CLOSER, WALL STOP, SS

THRESHOLD, 3 CAM-LIFT HINGES, REMOVABLE

CYLINDER - RFI-0005

BALANCED MAGNETIC SWITCH, LEVER SET, ALARMED,

NON-HOLD CLOSER, 8" KICK PLATE, WALL STOP, SS

THRESHOLD, 3 CAM-LIFT HINGES, REMOVABLE

CYLINDER

LEVER SET, NON-HOLD CLOSER, 8" KICK PLATE, WALL

STOP, SS THRESHOLD, 3 CAM-LIFT HINGES,

REMOVABLE CYLINDER

LEVER SET, NON-HOLD CLOSER, WALL STOP, SS

THRESHOLD, REMOVABLE CYLINDER

*SCHEDULE TO BE FINALIZED IN SHOP DRAWINGS.

PROVIDED BY USER

A1.02

RFI-0010, EXISTING HOLES

TREATED & SEALED PER

IAWICD 705

1' -4

" A P

P R

O

XI

M A

TE

WALL DETAIL

SCALE: 1" = 1'-0"

SHEET

Sheet of

WALL DETAIL

SCALE: 1" = 1'-0"

WALL DETAIL

SCALE: 1" = 1'-0"

WALL DETAIL

SCALE: 1" = 1'-0"

WALL DETAIL

SCALE: 1" = 1'-0"

WALL DETAIL

SCALE: 3" = 1'-0"

EXISTING FLOOR

1/2" ACOUSTICAL SEALANT JOINT

4" RESILIENT BASE

FINISH PRIMED & PAINTED

2 LAYERS OF 5/8" TYPE X GYP BOARD

3 5/8" METAL STUDS @ 16" O.C.

SOUND BATTS CONTINUOUS

3 5/8" METAL STUDS @ 16" O.C. TO

EXISTING DECK

EXTEND TO UNDERSIDE OF DECK

1/2" ACOUSTICAL SEALANT JOINT

ACOUSTICAL CEILING TILE

EXISTING FLOOR

1/2" ACOUSTICAL SEALANT JOINT

4" RESILIENT BASE

FINISH PRIMED & PAINTED

1 LAYER OF 5/8" TYPE X GYP BOARD

6" METAL STUDS @ 16" O.C.

SOUND BATTS CONTINUOUS

6" METAL STUDS @ 16" O.C. TO

EXISTING DECK

EXTEND TO UNDERSIDE OF DECK

1/2" ACOUSTICAL SEALANT JOINT

EXISTING FLOOR

1/2" ACOUSTICAL SEALANT JOINT

4" RESILIENT BASE

FINISH PRIMED & PAINTED

2 NEW LAYERS OF 5/8" TYPE X GYP BOARD

EXISTING 3 5/8" METAL STUDS @ 16" O.C.

TO INSTALL NEW SOUND BATTS CONTINUOUS

3 5/8" METAL STUDS @ 16" O.C. TO

EXISTING DECK

EXTEND TO UNDERSIDE OF DECK

1/2" ACOUSTICAL SEALANT JOINT

ACOUSTICAL CEILING TILE

EXISTING 3 5/8" METAL STUD WALL

REMOVE EXISTING LAYER OF GYPBOARD

EXISTING FLOOR

1/2" ACOUSTICAL SEALANT JOINT

NEW 4" RESILIENT BASE

EXISTING 3 5/8" METAL STUDS @ 16" O.C.

3 5/8" METAL STUDS @ 16" O.C. TO

EXISTING DECK

EXTEND TO UNDERSIDE OF DECK

1/2" ACOUSTICAL SEALANT JOINT

ACOUSTICAL CEILING TILE

EXISTING 3 5/8" METAL STUD WALL

@ EXISTING GYP BOARD FINISH

NEW 3 5/8" METAL STUDS @ 16" O.C.

SOUND BATTS CONTINUOUS

FINISH PRIMED & PAINTED

NEW 2 LAYERS OF 5/8" TYPE X GYP BOARD

EXISTING EXTERIOR WALL

PRIMED & PAINTED

2 NEW LAYERS 5/8" GYP BOARD FINISH

NEW 6" METAL STUDS @ 16" O.C.

1/2" SEALANT JOINT

R-19 MIN. INSULATION

NEW CMU BLOCK INFILL

TO MATCH EXISTING

WEEPS AS REQUIRED

CONTINUOUS FLASHING

OVER DENSGLASS

EXISTING EXTERIOR WALL

PRIMED & PAINTED

2 NEW LAYERS 5/8" GYP BOARD FINISH

NEW 6" METAL STUDS @ 16" O.C.

1/2" SEALANT JOINT

R-19 MIN. INSULATION

NEW CMU BLOCK INFILL

TO MATCH EXISTING

WEATHER BARRIER

EXISTING WALL

6" METAL STUD FRAMING

PRIMED & PAINTED

5/8" GYP BOARD FINISH

4" CORE IN CONCRETE SLAB

FINISH PRIMED & PAINTED

2 NEW LAYERS OF 5/8" TYPE X GYP BOARD

ACOUSTICAL CEILING TILE

NOTE:

STAGGER JOINTS OF GYP BOARD SO SEAMS DO NOT

ALIGN.

STABILIZE SOUND BATT LOCATION

INTERMEDIATE BLOCKING TO

STABILIZE SOUND BATT LOCATION

INTERMEDIATE BLOCKING TO

STABILIZE SOUND BATT LOCATION

INTERMEDIATE BLOCKING TO

STABILIZE SOUND BATT LOCATION

INTERMEDIATE BLOCKING TO

OVER DENSGLASS

WEATHER BARRIER

FINISH PRIMED & PAINTED

1 LAYER OF 5/8" TYPE X GYP BOARD

FINISH PRIMED & PAINTED

1 LAYER OF 5/8" TYPE X GYP BOARD

FINISH PRIMED & PAINTED

1 LAYER OF 5/8" TYPE X GYP BOARD

FINISH PRIMED & PAINTED ON CONTROL SIDE

FASTENED TO EXISTING STUD WALL;

SILL DETAIL

SCALE: 3" = 1'-0"

JAMB DETAIL

SCALE: 3" = 1'-0"

HEAD DETAIL

SCALE: 3" = 1'-0"

BATT INSULATION

DOOR AS SCHEDULED

(NO-HOLE)

SEALANT

BOARD SHEATHING

DOOR AS SCHEDULED

DOOR FRAME BEYOND

2 LAYERS OF 5/8" GYP

BATT INSULATION

DOOR AS SCHEDULED

2x WOOD BUCK

16ga METAL STUD JAMB (NO-HOLE)

SEALANT

BOARD SHEATHING

METAL DOOR FRAME

2 LAYERS OF 5/8" GYP

REFERENCE SHOP DRAWINGS

REFERENCE SHOP DRAWINGS

FOR ACOUSTICAL THRESHOLD

FOR ACOUSTICAL TREATMENT

2x WOOD BUCK

METAL DOOR FRAME

REFERENCE SHOP DRAWINGS

FOR ACOUSTICAL TREATMENT

6" METAL STUD WALL

6" METAL STUD WALL

EXTEND FROM SLAB TO STRUCTURE

16ga METAL STUD HEADER

CONTROL SIDE CONTROL SIDE CONTROL SIDECONTROL SIDE

A1.10

MATCH EXISTING

ANCHORAGE TO

MATCH EXISTING

ANCHORAGE TO

1 LAYER OF 5/8" TYPE X GYP BOARD

WALL CONSTRUCTED PER RFI0014

EXISTING CARPET TO REMAIN BENEATH

ALL NEW METAL TRACK-RFI-0006

EXISTING CARPET TO REMAIN BENEATH

ALL NEW METAL TRACK-RFI-0006

EXISTING CARPET TO REMAIN BENEATH

ALL NEW METAL TRACK-RFI-0006

EXISTING CARPET TO REMAIN BENEATH

ALL NEW METAL TRACK-RFI-0006

MECHANICAL SYMBOLS

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

FLOOR PLAN

SCALE: 1/4" = 1'-0"

1 2' 0 2' 4'

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

CONSTRUCTION IN THE PROJECT AREA.

AS-BUILT DRAWINGS

R

E V

I S

I O

N

DEMOLITION PLAN

1 2' 0 2' 4'

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

1 2' 0 2' 4'

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

CONSTRUCTION IN THE PROJECT AREA.

AS-BUILT DRAWINGS

R

E V

I S

I O

N

NOT TO SCALE

CONDENSER UNIT DETAIL

NOT TO SCALE

CEILING DIFFUSER DETAIL

NOT TO SCALE

BRANCH DUCT DETAILS

01 02 03

NOT TO SCALE

CONDENSATE DRAIN

NOT TO SCALE

FIRE DAMPER DETAIL

NOT TO SCALE

CONDENSER UNIT PAD DETAIL

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

NOT TO SCALE

CONDENSER UNIT TIE-DOWN DETAIL

NOT TO SCALE

DUCTWORK SUPPORT DETAILS

NOT TO SCALE

MINI SPLIT AIR HANDLER DETAIL

NOT TO SCALE

BOLLARD DETAIL

NOT TO SCALE

RETURN AIR GRILLE/BOOT DETAIL

NOT TO SCALE

PIPE HANGER DETAILS

NOT TO SCALE

TYPICAL LOW PRESSURE

"TEE" DUCT FITTING DETAIL

NOT TO SCALE

HVAC SECURE WALL PENETRATION DETAIL

NOT TO SCALE

VAV TERMINAL WITH ELECT. HEAT

NOT TO SCALE

TRANSFER AIR DETAIL

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

1 2' 0 2' 4'

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

CONSTRUCTION IN THE PROJECT AREA.

AS-BUILT DRAWINGS

TYPICAL BLUE STROBE DETAIL

TYPICAL SECURITY ROUGH-IN DETAIL

NEW LUMINAIRE SCHEDULE

SECURE WALL/FOOR PENETRATION DETAIL TRANSFORMER CONNECTION DETAIL

System No. W-L-3026

F Ratings -1 and 2 Hr (see item 1)

L Rating - 1 and 2 Hr (see item 1)

Through-penetration Firestop

Wall Assembly

Studs

Gypsum Board *

Cables

Fill, Void of Cavity Material * - Caulk -

EGS NELSON FIRESTOP

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

CONSTRUCTION IN THE PROJECT AREA.

AS-BUILT DRAWINGS

L Rating At 400 F -less than I CFM/sq ft

L Rating At Ambient -less than 1 CFM/sq ft

T Ratings -0, 1,2,3, and 4 Hr (See Item 3)

F Ratings -1,2,3 and 4 Hr (See Items 2 and 3)

System No. W-L-1001

Through-penetration Firestop Systems

RatingRatingor Conduit

3M COMPANY

Diam In HrHr

Fill Void or Cavity Material* - Caulk

Max Pipe

WARD MFG INC

A BUNDY CO

TITEFLEX CORP

OMEGA FLEX INC

TF

Through Penetrating Product*

Copper Pipe

Copper Tubing

Conduit

Through-Penetrant

Iron Pipe

Steel Pipe

Wall Assembly

Gypsum Board*

Studs

FIRESTOP SYSTEM

MC TYPE CABLE

3M COMPANY

Nom PipeMin Floor

Tube or Conduit

Diam In.

or Wall

Thkns In.

Fill Void or Cavity Material* - Caulk,Sealant -

Rating Hr

Max Annular

Space In.

Mln Caulk

Thkns In.

F

Packing Material

Steel Pipe

Iron Pipe

Conduit

Conduit

Copper

Copper

Steel Sleeve

Through Penetrants

Precast Concrete UnIts

Floor or Wall Assembly -

Concrete Blocks

Concrete Blocks*

Precast Concrete UnIts*

System No. C-AJ-1044

F Ratings -2,3, and 4 Hr (See Items 2A and 4)

T Rating -0 Hr

L Rating At Ambient -2 CFM/sq ft

L Rating At 400 F -less than 1 CFM/sq ft

Through-penetration Firestop

W Rating - Class 1 (see item 4)

Forming Material* -

PARTIAL 1ST FLOOR PLAN

1 2' 0 2' 4'

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

E1-0.2

DEMOLITION PLAN

SCALE: 1/4" = 1'-0"

1 2' 0 2' 4'

RENOVATED FLOOR PLAN

SCALE: 1/4" = 1'-0"

2 2' 0 2' 4'

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

CONSTRUCTION IN THE PROJECT AREA.

AS-BUILT DRAWINGS

ENLARGED EXISTING ELECTRICAL ROOM PLAN

SCALE: 1/4" = 1'-0"

3 2' 0 2' 4'

ENLARGED COMMUNICATIONS ROOM PLAN

4 2' 0 2' 4'

DEMOLITION PLAN

1 2' 0 2' 4'

RENOVATED FLOOR PLAN

SCALE: 1/4" = 1'-0"

2 2' 0 2' 4'

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

Luminaire Schedule

Scene: NORMAL

Symbol Qty Label Arrangement Total Lamp Lumens LLF Description

Calculation Summary

Scene: NORMAL

Label CalcType Units Avg Max Min Avg/Min Max/Min

Calculation Summary

Scene: EMEREGENCY

Label CalcType Units Max Min Avg/Min Max/Min

Luminaire Schedule

Scene: EMERGENCY

Symbol Qty Label Arrangement Total Lamp Lumens LLF Description

ELECTRICAL PHOTOMETRIC PLAN - NORMAL LIGHTING

SCALE: 1/4" = 1'-0"

1 2' 0 2' 4'

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

CONSTRUCTION IN THE PROJECT AREA.

AS-BUILT DRAWINGS

ELECTRICAL PHOTOMETRIC PLAN - EMERGENCY LIGHTING

2 2' 0 2' 4'

E3-0.1

DEMOLITION PLAN

SCALE: 1/4" = 1'-0"

1 2' 0 2' 4'

RENOVATED FLOOR PLAN

SCALE: 1/4" = 1'-0"

2 2' 0 2' 4'

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

CONSTRUCTION IN THE PROJECT AREA.

AS-BUILT DRAWINGS

ENLARGED COMMUNICATIONS CLOSET PLAN

3 2' 0 2' 4'

PARTIAL ELECTRICAL ONE LINE

SCALE: NTS

PARTIAL FIRE ALARM RISER

SCALE: NTS

SECURE DIGITAL PHONE RISER

SCALE: NTS

SPAWN RISER

SCALE: NTS

SIPRNET RISER

SCALE: NTS

NIPRNET RISER

SCALE: NTS

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

CONSTRUCTION IN THE PROJECT AREA.

AS-BUILT DRAWINGS

UNCLASSIFIED OUTLET DETAIL

SCALE: NTS

CCTV RISER

SCALE: NTS

CLASSIFIED OUTLET DETAIL

SCALE: NTS

PRINTER OUTLET DETAIL

SCALE: NTS

IDS AND ENTRY CONTROL RISER

BLUE LIGHT RISER

SHEET

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

CONSTRUCTION IN THE PROJECT AREA.

AS-BUILT DRAWINGS

BLUE STROBE LIGHT CONTROL SCHEMATIC

SCALE: NTS

4-POST RACK 4-POST RACK

C A

B L E

M

A N

A G

E M

E N

T

C A

B

N

A G

E M

E N

T

C A

B

N

A G

E M

E N

T

C A

B

N

A G

E M

E N

T

C-01 C-01

C-02 C-02

4-POST RACK

C A

B

N

A G

E M

E N

T C

A B

N

A G

E M

E N

T

C-01

C-02

COMMUNICATION SYSTEMS RACK ELEVATION DETAIL

SCALE: NTS

C-01

C-03

C-04

C-02

PATCH PANEL DETAILS

Sheet of

THESE AS-BUILT DRAWINGS ARE INTENDED TO DISPLAY

THE COMPLETED WORK SUBSTANTIALLY AS

CONSTRUCTED. THEY ARE BASED ON DATA FURNISHED BY

THE CONTRACTOR(S) TO THE ENGINEER. FIELD

VERIFICATION OF CONDITIONS AND LOCATIONS SHOULD

BE UNDERTAKEN PRIOR TO ALTERATIONS OR

Cover Sheet As-Builts
A1.01 DEMOLITION PLAN
A1.02 FLOOR PLANS
A1.10 DETAILS
Mechanical As-Builts
Fire Protection As-Builts
Electrical As-Builts