JA-4_T4_Appx_3 _Existing_Panel _final.pdf
PDF 718 KB Posted
- Attached to
- Turbine-Generator #4 Federal contract opportunity
- Solicitation number
- FA5004-14-R-C008
About this file
Attachment JA-4
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA5004-14-R-C008-0005.pdf | ||
| JA-19_Question_and_Answer__3.pdf | ||
| FA5004-14-R-C008-0004.pdf | ||
| FA5004-14-R-C008-0003.pdf | ||
| JA-18_Question_and_Answer__2.pdf | ||
| FA5004-14-R-C008-0002.pdf | ||
| JA-17_Example_LRR.pdf | ||
| JA-16_Question_and_Answer__1.pdf | ||
| FA5004-14-R-C008-0001.pdf | ||
| JA-13_AF_Form_3000.pdf | ||
| JA-12_T4_AF_Form_66.pdf | ||
| JA-11_Wage_Determination_AK20130001.pdf | ||
| JA-9_Past_Performance_Worksheet.docx | DOCX document | |
| JA-5_T4_Appx_4 _New_Panel.pdf | ||
| JA-10_Financial_Reference_Sheet.docx | DOCX document | |
| JA-1_T4_Specifications.pdf | ||
| JA-8_Past_Performance_Questionnaire.docx | DOCX document | |
| JA-15_AF_Form_3065.pdf | ||
| JA-14_AF_Form_3064.pdf | ||
| JA-6_T4_Appx_5 _O M_Manual.pdf | ||
| JA-3_T4_Appx_2 _Photos_w_mark-up.pdf | ||
| JA-2_T4_Appx_1 _Inspections.pdf | ||
| FA5004-14-R-C008.pdf |
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAINTAIN TURBINE-GENERATOR #4 APPENDIX 3
EIELSON AFB, ALASKA EXISTING CONTROL PANEL
FTQW 15-1001
EXISTING
CONTROL PANEL
APPENDIX 3
MAINTAIN TURBINE-GENERATOR#4
EIELSON AFB, ALASKA
FTQW 15-1001
ATTACHMENT JA-4
EXISTING PANEL, FINAL
SOLICITATION FA5004-14-R-C008
Existing Control Panel Face
MAINTAIN TURBINE-GENERATOR#4
EIELSON AFB, ALASKA
FTQW 15-1001
ATTACHMENT JA-4
Turbine #4 Existing Control Panel Legend
1. Bently-Nevada Touchscreen Monitor (reuse)
2. Condenser Vacuum (30 – 0 inches Hg)
3. Inlet Steam Pressure (0-1,000 psi)
4. Cooling Water Header Pressure (30 inches Hg – 60 psi)
5. Turbine Throttle Pressure (0-1,000 psi)
6. 100 psi Extraction Steam (0-200 psi)
7. Condensate Pump Discharge Pressure (0-100 psi)
8. Inlet Steam Temperature (0-1,000 oF)
9. Tachometer (abandoned)
10. Annunciator Panel
11. Stator Temperature (0-250 oF)
12. Mercury Vacuum Gauge (reuse)
13. Generator Air Cooler Controller (reuse)
14. Inlet Steam Totalizer
15. Digital Tachometer
16. Annunciator Panel Control Pushbuttons (test, acknowledge, flasher reset, system reset)
17. Yokogawa Multi-Input LCD Chart Recorder (reuse)
18. Extraction Steam Totalizer
19. Vibration monitor trip defeat switch
20. Turbo Sentry overspeed trip (reuse)
21. Extraction Isolation Valve Control Pushbuttons and Pilot Lights
22. Hotwell pump pushbuttons and pilot lights
23. Generator Load Control Selector Switch and Pilot Lights
24. Oil Pump Selector Switches and Pilot Lights
25. Idle/Synch Speed Selector Switch
26. Woodward 505E Governor (reuse)
27. Governor Trip Indications “Cheat Sheet”
28. Bently-Nevada 3500 Vibration & Temperature Monitoring Rack (reuse)
MAINTAIN TURBINE-GENERATOR#4
EIELSON AFB, ALASKA
FTQW 15-1001
ATTACHMENT JA-4
Existing Control Panel
Demolish Light Fixtures & Replace with New Fixture
Replace Existing Horn and Strobe
Reinstall Barometer on Side of Rebuilt Control Panel
Remove Digital Displays & Reinstall in Approximately Same Locations
MAINTAIN TURBINE-GENERATOR#4
EIELSON AFB, ALASKA
FTQW 15-1001
ATTACHMENT JA-4