JA-3_T4_Appx_2 _Photos_w_mark-up.pdf

PDF 3 MB Posted

Attached to
Turbine-Generator #4 Federal contract opportunity
Solicitation number
FA5004-14-R-C008
Issued by
Department of the Air Force Pacific Air Forces

About this file

Attachment JA-3

View the file

Other files for this federal contract opportunity

Other files attached to Turbine-Generator #4, newest first.
File Type Posted
FA5004-14-R-C008-0005.pdf PDF
JA-19_Question_and_Answer__3.pdf PDF
FA5004-14-R-C008-0004.pdf PDF
FA5004-14-R-C008-0003.pdf PDF
JA-18_Question_and_Answer__2.pdf PDF
FA5004-14-R-C008-0002.pdf PDF
JA-17_Example_LRR.pdf PDF
JA-16_Question_and_Answer__1.pdf PDF
FA5004-14-R-C008-0001.pdf PDF
JA-12_T4_AF_Form_66.pdf PDF
JA-11_Wage_Determination_AK20130001.pdf PDF
JA-13_AF_Form_3000.pdf PDF
JA-9_Past_Performance_Worksheet.docx DOCX document
JA-5_T4_Appx_4 _New_Panel.pdf PDF
JA-10_Financial_Reference_Sheet.docx DOCX document
JA-1_T4_Specifications.pdf PDF
JA-8_Past_Performance_Questionnaire.docx DOCX document
JA-15_AF_Form_3065.pdf PDF
JA-14_AF_Form_3064.pdf PDF
JA-4_T4_Appx_3 _Existing_Panel _final.pdf PDF
JA-6_T4_Appx_5 _O M_Manual.pdf PDF
JA-2_T4_Appx_1 _Inspections.pdf PDF
FA5004-14-R-C008.pdf PDF
Show all 23

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MAINTAIN TURBINE-GENERATOR #4 APPENDIX 2

EIELSON AFB, ALASKA PHOTOGRAPHS

FTQW 15-1001

Appendix 2 - 1

PHOTOGRAPHS

APPENDIX 2

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

PHOTOS W/ MARK-UP

SOLICITATION FA5004-14-R-C008

FTQW 15-1001

Appendix 2 - 2

Turbine-Genrator #4, Turbine End

T&T Valve

Steam Seal Control Valves

Turbine- Generator #4, Generator End

Exciter Doghouse

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 3

Primary Valve Cam Shaft & Servomotor

Secondary Valve Cam Shaft

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 4

Extraction Non-Return Valve

Main Steam Line Strainer

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 5

Extraction Isolation Valve & Actuator

Extraction Valve

Local Extraction Valve Controls On Generator Foundation

Extraction Valve Controls.

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 6

Atmospheric Relief Valve

Hotwell Pumps

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 7

Main Oil Pumps

Oil Coolers

Oil Cooler Transfer Valve

Oil cooler transfer valve

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 8

Oil Cooler Temperature Control Valve & Bypass

Oil Tank, East End

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 9

Main Condenser, East End

Main Condenser, West End

Extraction Non-Return Valve

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 10

Approximate Location of New Condenser Water Meter

Install meter in trench approx.

here. Do not block cage access.

Install Butterfly Valve in trench approx. here. Do not block cage access.

Install Meter Display Here.

Main condenser, East End

Hotwell Level Controls

Level ControllerLevel Sensors

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 11

Condenser Recirc. Valve

Condensate Return Valve Condensate Return Valve Controller

Oil Coolers

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 12

Air Ejection System

Hogger Jet

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 13

Air Ejection System Traps, Next to Hotwell

Gland Seal Condenser

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 14

New Alternate Cooling Water Line - Looking North

Existing 6" Water Line in Trench

New 6" Gate Valve

New 3" Water Line in Trench

Rotate Existing Valve 90 Degrees to Avoid Conflict with New Pipe

Connect to Stator Cooler Supply Line

Stator Cooler Supply Line

New 3" Gate Valve

Red Pipe: Under Floor Green: Above Floor

Stator Cooler Cooling Water Supply & Return Piping

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 15

New Alternate Cooling Water Supply - Looking South

Existing 6" Water Line in Trench

Oil Cooler Cooling Water Supply

New 3" Water Line

New 2" Water Line

Red Pipe: Under Floor Green: Above Floor

Gland Seal Condenser Cooling Water Supply

Generator Leads Inside High Voltage Cage

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3

FTQW 15-1001

Appendix 2 - 16

Ground Resistor in High Voltage Cage Under Generator

MAINTAIN TURBINE-GENERATOR#4

EIELSON AFB, ALASKA

FTQW 15-1001

ATTACHMENT JA-3