MAINTAIN TURBINE-GENERATOR #5 APPENDIX 3
EIELSON AFB, ALASKA EXISTING CONTROL PANELS
FTQW 12-1015
EXISTING
CONTROL PANELS
APPENDIX 3
A B C
D E O
F G
H I J
K L M
N
P
Q
Q1
R
S
T U
V
W
X
Y Z AA BA CA DA EA
FA
GA HA IA JA
KA
LA MA NA
OA
PA QA RA SA
TA
UA
VA WA
XA
YA ZA AB
BB
CB
DB
EB
FB
GB
HB
IB
EXISTING MAIN CONTROL PANEL
EXISTING TG-5 CONTROL PANEL FACE COMPONENTS
A Main Steam Pressure (Inlet) 0-1000 psig
B Main Steam Temp (Inlet) 50-750 oF
C Steam Chest Pressure 0-500 psig
D First Stage Pressure 0-500 psig
E Extraction Pressure 0-200 psig
F Main Oil Pump Discharge 0-300 psig
G Exhaust, Wide Range 30” Hg vac – 15 psig
H Power Oil 0-300 psig
I Control Oil 0-300 psig
J Lube Oil 0-60 psig
K Steam Seal 0-30 psig
L Gland Steam Condenser 40” H20 vac – 15 psig
M Circ Water Header 0 – 30 psig
N Condensate Pump discharge 0 – 60 psig
O Exhaust, Narrow Range 0 - 6.5” Hg Abs.
P Annunciator Panel 6 x 5
TG-5 Stop Valve Trip
Diesel Generator
Power Circuit Breaker
Diesel Generator
Trip
TG-5 Turbine Exhaust
Vacuum Low
TG-5
Vibration
High
TG-5 Oil Pressure Low
TG-5 Bearing Temperature
High Trip
TG-5 Trip TG-5 Oil Reservoir
Level High/Low
TG-5 Stator Air
Temperature High
Tg-5 Condenser
Hotwell Level High
TG-5
Condenser
Hotwell Level Low
TG-5
Condenser
Hotwell Level Low-Low
TG-5
Condensate Pumps Low
Pressure Auto-Start
Diesel Generator
Panel Trouble
Condensate Return Drain Tk Level-Hi
Sanitary Sump Level
Hi-Hi
TG-5 Bsmt Sump Level
Hi-Hi
DG Day Tank High
Dg Day Tank Low
TG-5 Bearing Temp High
TG-5 Ground Fault
Generator Drain High
Oil Temp High
Exhaust Temp High
DG Radiator Fan Failure
Q Bently-Nevada Monitor Rack
Q1 (Vibration Monitor) Trip Defeat Switch Selector sw - Normal/Defeat
R Panalarm (Annunciator Panel) Functions Acknowledge, Test, Flasher Reset, Panalarm Reset
S Digital Tach
T Main Steam Valve Close-Stop-Open red pilot – open, green pilot – close, Selector sw
U Yokogawa Monitor
V TG #5 reset pushbutton
W Bently-Nevada touch screen
X Idle / Sych Speed selector switch
Y Trip & Throttle Valve Test red pilot – open, green pilot – closed, amber pilot – test, test pushbutton
Z Gland Steam Exhauster red pilot – run, green pilot – off, black push button – run, red pushbutton – off
AA Extraction Non-Return Valve red pilot – open, green pilot – close BA Condensate Pump A red pilot – run, green pilot – off, H-O-A selector sw
CA Condesate Pump B red pilot – run, green pilot – off, H-O-A selector sw
DA Extraction Valve red pilot – open, green pilot – close, selector sw – close, auto, open
EA Oil Heater red pilot – run, green pilot – off, selector sw – enable, off
FA Condensate Return to Condensate Hotwell Totalizer
GA Main Oil Pump AC (West) red pilot – run, green pilot – off H-O-A Selector Sw
HA Aux Oil Pump AC (Center) red pilot – run, green pilot – off H-O-A Selector Sw
IA Turning Gear red pilot – engaged, green pilot – disengaged Red pilot – auto, green pilot – off Auto-off selector switch
JA Emergency Oil Pump DC red pilot – run, green pilot – off H-O-A Selector Sw
KA Keyboard for Bently-Nevada Monitor
LA Oil Vapor Extractor red pilot – run, green pilot – off Black pushbutton – run Red pushbutton – off
MA Steam Drain Valves red pilot – open, green pilot – close Selector sw – auto-open
NA Condensate Pumps Recirc Valve red pilot – open, green pilot – close Selector sw – auto-open
OA TG-5 Hours Totalizer
PA TG-5 Exciter Amps 0-20 DC Amps
QA Volt Incoming 0-9000 AC Volts
RA Frequency Incoming 55-65 Hz
SA TG-5 B Phase Current 0-1200 AC Amps
TA TG-5 Exciter Emergency Stop Covered switch
UA Manual / Load Control red pilot – manual enabled Selector sw – manual / GE load control Red pilot – load share alarm Green lighted pushbutton – 505 Reset Note: “1) Switch to 505 Manual
2) Press 505 Reset”
VA Diesel Generator Exciter Volts 0-150 DC Volts
WA Black Start Generator Fequency 55-65 Hz
XA Diesel Generator Breaker Green lighted pushbutton
YA Diesel Generator Frequency 55-65 Hz
ZA Diesel Generator AC volts 0-9000 AC volts A to C Phase Only
AB Diesel Generator Ampmeter 0-300 AC Amps B Phase Only
BB Woodward 505E Governor
CB Diesel Generator H-O-A H-O-A Selector Sw Label: “Leave in Auto for GE” Label: “Off ??? GE Start/Stop”
DB Diesel Generator Voltage Adjust Selector Sw – raise/lower
EB Diesel Generator Soakback Pump Selector Sw – off/on Label: “Run 20 Min Before and After Starting Diesel Gen”
FB Diesel Generator Emergency Stop red pushbutton
GB Governor Trip Announcements (cheat sheet)
HB Diesel Generator Voltage Adjust Voltage control Mode Selector Sw – Off/Manual/Auto Knob – manual voltage adjustment
IB Alarm Horn
EMD PANEL
| Appx 3, Existing Panels |
| T5_Appx 3, Existing Panels |
| Control Panel |
| EMD Panel |
Control Panel - Existing