NATIVE SOIL COMPACTED

TO 95% DENSITY OR

NEW PAVEMENT

B

B

N.T.S.

SECTION B−B

4" NON−PERFORATED PVC PIPE AND

FITTINGS WHERE SHOWN ON PLANS.

SEE E−6101 FOR SCHEDULE.

UNDISTURBED EARTH

BURIAL DEPTH AS REQUIRED

TO DRAIN.

FINISHED GRADE

#4 BARE COPPER

COUNTERPOISE

3"

MINIMUM DEPTH:

2−WAY DUCTS − 29 INCHES

ALL OTHER DUCTS − 24 INCHES

INTERMEDIATE SPACER

BASE SPACER

USE SIDE FORMS

WHERE NECESSARY

WARNING TAPE

CONCRETE

ENCASED DUCT

BANK. SEE NOTE 2.

4" X 10’ COPPER

CLAD GROUND

ROD

BOND COUNDERPOISE TO

GROUND ROD USING ONE SHOT

EXOTHERMIC WELD

12"

MIN.

N.T.S.

30" #4 TIE BAR. MINIMUM 4 PER COLD JOINT

EMBEDDED IN WET CONCRETE. (TYP)

15"

2.25"

2.25"

SEE E−5301 FOR DUCT

BANK CONFIGURATIONS

#4 TIE BARS WHERE

NEEDED. SEE COLD

JOINT DETAIL THIS

SHEET.

2.25"

2.25"

4’−0"

MAX

2" NOMINAL CONDUIT

SUPPORT AS NEEDED TO KEEP

TIE BAR HORIZONTAL. (TYP)

1. FOR NON−METALLIC CONDUITS, TERMINATE WITH PLASTIC COUPLINGS SET FLUSH WITH

END OF CONCRETE ENVELOPE AND INSTALL PLASTIC PLUGS.

2. CONCRETE FOR CONCRETE ENCASED DUCT SHALL CONTAIN A RED DYE TO IDENTIFY

DUCT AS AIRFIELD ELECTRICAL DUCT BANK.

3. INSTALL COUNTERPOISE WITH ALL DUCT BANK AND CONDUIT.

4. DO NOT CONNECT COUNTERPOISE TO LIGHT BASES OR MANHOLES/HANDHOLES

GROUNDING COMPONENTS. LOOP COUNTERPOISE AROUND ALL MANHOLES.

5. PROVIDE GROUND RODS SPACED MAX. 1,000−FT.

6. WHEN UNDER PAVEMENT PLACE COUNTERPOISE ON NEXT−TO−LAST LIFT OF COMPACTED

BASE MATERIAL.

7. SEE SHEET E−5301 FOR RE−INFORCEMENT DETAILS.

8. PLACE EACH SERIES CIRCUIT IN ITS OWN 2 INCH CONCRETE ENCASED PVC CONDUIT. USE

#6 AWG, 5KV, FAA L−824 CONDUCTORS AND ONE #6 AWG, THWN GREEN INSULATED

GROUND PER CIRCUIT.

9. DO NOT BACKFILL OVER COUNTERPOISE BEFORE COR HAS TESTED EXOTHERMIC WELDS

WITH A HAMMER AND VISUALLY INSPECTED COUNTERPOISE.

3’ − 8’

3"

MIN.

1"

MIN.

BACKFILL WITH SUBDRAIN

BEDDING MATERIAL

(33 46 16)

D U

C T

B A

N K

A N

D C

O U

N T

E R

P O

IS

E

C O

N S

T R

U C

T

IO

N D

E T

A

IL

S

A B C D E F G H I

D e s ig n b y:

D w n b y:

P a g e

S iz e

C M

T P

R O

JE

C

T

P lo t D a te

P ro je c t D a te

C h k b y:

D E

S C

R

IP

T

IO

N A

P P

R O

V E

D

A t

F u ll S iz e

S h e e t 2

"x

P R

O J E

C T

N U

M B

E R

Sheet of

Dwg. No.

C o p yr ig h t

C M

T

In c.

c

C O

N S

U

LT

IN

G

E N

G

IN

E E

R S

C R

A W

F O

R D

, M U

R P

H Y

T

IL

LY

, I N

C

W . W

A S

H

IN

G T

O N

S T

R E

E T

S P

R

IN

G F

IE

LD

, I L

(2

)7

-8 w w w .c m te ng r.

co m

D A

T E

YT C

BILI MO

M

MO

I A

R D

AN

P lo t B y:

−J u l−

:3

T o m M e m m in g e r

P lo t S c a le

:2

R E

V

IS

IO

N

VOL. 1 of 1

A p p ro ve d

THOMAS

MEMMINGER

062−053744

STA

TE OF ILLINO

IS

P R

Q E

−0 P

R E

P A

IR

S

O U

T H

D U

C T

B A

N K

PRQE 05−0101P2

E−5302

M C

C O

N N

E L

L A

F B

K

A N

S A

S

D

C

IV

IL

E

N G

IN

E

E R

IN

G

S Q

U A

D R

O N

A

IR

M O

B

IL

IT

Y

C O

M M

A N

D

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

−M A

R −2

A

JG

C M

T

A

JG

−0

E −5

T M

DC 1

D E

S

IG

N C

H A

N G

E

−J

U L −1

T

M

DC01 23-JUL-13

FA4621-13-R-0003 Duct Bank and Counterpoise Attachment 10

File details come from the government source that posted it. Updated .