Attachment_1-Specifications.pdf

PDF 8 MB Posted

Attached to
Repair 307th BW AMXS B6825 Federal contract opportunity
Solicitation number
FA4608-16-R-0011
Issued by
Department of the Air Force Global Strike Command

About this file

Attachment_1-Specifications.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Repair 307th BW AMXS B6825, newest first.
File Type Posted
A3.7.pdf PDF
Architect_Clarification_on_A3.7.docx DOCX document
Question_Set_5 _1_June_2016_(Final).docx DOCX document
CD_No1-Model.pdf PDF
Question_Set_4 _24_May_2016.docx DOCX document
A3.15_Enlarged_Elevator_Plans_Penthouse_Detail.pdf PDF
Amendment_0003.pdf PDF
Revised_Specs.pdf PDF
Question_Set_3 _17_May_2016.docx DOCX document
Question_Set_2 _10_May_2016.docx DOCX document
Site_Visit_Sign_In_Sheet.pdf PDF
Amendment_0002.pdf PDF
Question_Set_1_2_May_2016.docx DOCX document
Drawings_PDF.zip ZIP file
Attachment_8_-_Revised_PPQ_Cover_Letter.pdf PDF
Attachment_5-_Insurance.pdf PDF
Amendment_0001_Attachment_8_Revised.pdf PDF
Attachment_2-Drawings.pdf PDF
FA4608-16-R-0011.pdf PDF
Attachment_11-Bid_Schedule.xls XLS spreadsheet
Attachment_7_-_Past_Performance_Questionnaire.pdf PDF
Attachment_6-Wage_Determinations.pdf PDF
Attachment_3-_Environmental_Req'ts_(Oct_15).pdf PDF
Attachment_10_-_Subcontractor_Consent_Form.pdf PDF
Attachment_9-_Special_Contract_Requirements.pdf PDF
Attachment_8_-_PPQ_Cover_Letter.pdf PDF
Attachment_4_-_AF66.pdf PDF
Amendment_0001.pdf PDF
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 01100 – SUMMARY OF WORK

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes:

1. Project information.

2. Work covered by Contract Documents.

3. Phased construction.

4. Work under separate contracts.

5. Access to site.

6. Coordination with occupants.

7. Work restrictions.

8. Specification and drawing conventions.

B. Related Section:

1. Division 1 Section "Temporary Facilities and Controls" for limitations and procedures governing temporary use of Owner's facilities.

1.2 PROJECT INFORMATION

A. Project Identification: Repair AMXS (307th BW), B6825

B. Project Location: Barksdale AFB, Louisiana 71111.

C. Owner: Barksdale Air Force Base.

D. Owner's Representative:

E. Design Architect: Kevin Bryan Architect, 712 Texas Street, Shreveport, Louisiana 71101, (318) 673-9980.

F. Project Manager: Nathan E. Tracer, Architect, 2CES, (318) 456-3089.

1.3 WORK COVERED BY CONTRACT DOCUMENTS

A. The Work of the Project is defined by the Contract Documents and consists of the following:

B. The project consists of the renovation and repairs to Building 6825 and adjacent structures. Construction shall include but not be limited to new gypsum board partitions, Plaster repairs and patching back, hollow metal frames, flush wood doors, ceramic tile, tile carpet, new door hardware, new KALWAL translucent panels to replace some exterior windows and doors, rubber base, rubber treads, and nosings, laminated glass, millwork, and full replacement of HVAC and electrical systems, as well as the addition of full Fire Suppression System.

FA4608-16-R-0011

Attachment 1

C. Type of Contract.

1. Project will be constructed under a single prime contract.

1.4 WORK UNDER SEPARATE CONTRACTS

A. General: Cooperate fully with separate contractors so work on those contracts may be carried out smoothly, without interfering with or delaying work under this Contract or other contracts. Coordinate the Work of this Contract with work performed under separate contracts.

1.5 ACCESS TO SITE

A. General: Contractor shall have limited use of Project site for construction operations as indicated on Drawings by the Contract limits and as indicated by requirements of this Section.

B. Use of Site: Limit use of Project site to areas within the Contract limits indicated. Do not disturb portions of Project site beyond areas in which the Work is indicated.

1. Limits: Confine construction operations to primary construction area as bound by site plan drawing.

2. Limits: Limit site disturbance, including earthwork and clearing of vegetation, to 40 feet beyond building perimeter; 10 feet beyond surface walkways, patios, surface parking, and utilities less than 12 inches in diameter; 15 feet beyond primary roadway curbs and main utility branch trenches; and 25 feet beyond constructed areas with permeable surfaces.

3. Schedule deliveries to minimize use of driveways and entrances by construction operations.

4. Schedule deliveries to minimize space and time requirements for storage of materials and equipment on-site.

1.6 WORK RESTRICTIONS

A. Work Restrictions, General: Comply with restrictions on construction operations.

1. Comply with limitations on use of public streets and other requirements of authorities having jurisdiction.

2. Existing Utility Interruptions: Do not interrupt utilities serving facilities occupied by Owner or others unless permitted under the following conditions and then only after providing temporary utility services according to requirements indicated:

3. Notify Architect, Owner not less than seven days in advance of proposed utility interruptions.

4. Obtain Architect's written permission before proceeding with utility interruptions.

FA4608-16-R-0011

1.7 SPECIFICATION AND DRAWING CONVENTIONS

A. Specification Content: The Specifications use certain conventions for the style of language and the intended meaning of certain terms, words, and phrases when used in particular situations. These conventions are as follows:

1. Imperative mood and streamlined language are generally used in the Specifications. The words "shall," "shall be," or "shall comply with," depending on the context, are implied where a colon (:) is used within a sentence or phrase.

2. Specification requirements are to be performed by Contractor unless specifically stated otherwise.

B. Division 1 General Requirements: Requirements of Sections in Division 1 apply to the Work of all Sections in the Specifications.

C. Drawing Coordination: Requirements for materials and products identified on the Drawings are described in detail in the Specifications. One or more of the following are used on the Drawings to identify materials and products:

1. Terminology: Materials and products are identified by the typical generic terms used in the individual Specifications Sections.

2. Abbreviations: Materials and products are identified by abbreviations scheduled on Drawings.

PART 2 - PRODUCTS (Not Used)

PART 3 - EXECUTION (Not Used)

END OF SECTION 01100

FA4608-16-R-0011

SECTION 01732 - SELECTIVE DEMOLITION

1.1 SUMMARY

A. Section Includes:

1. Demolition and removal of selected site elements.

1.2 DEFINITIONS

A. Remove: Detach items from existing construction and legally dispose of them off-site unless indicated to be removed and salvaged or removed and reinstalled.

B. Remove and Salvage: Carefully detach from existing construction, in a manner to prevent damage, and deliver to Owner ready for reuse.

C. Remove and Reinstall: Detach items from existing construction, prepare for reuse, and reinstall where indicated.

D. Existing to Remain: Existing items of construction that are not to be permanently removed and that are not otherwise indicated to be removed, removed and salvaged, or removed and reinstalled.

1.3 PREINSTALLATION MEETINGS

A. Predemolition Conference: Conduct conference at per Owner direction.

1.4 INFORMATIONAL SUBMITTALS

A. Qualification Data: For refrigerant recovery technician.

B. Predemolition Photographs or Video: Submit before Work begins.

C. Statement of Refrigerant Recovery: Signed by refrigerant recovery technician.

1.5 CLOSEOUT SUBMITTALS

A. Landfill Records: Indicate receipt and acceptance of hazardous wastes by a landfill facility licensed to accept hazardous wastes.

1.6 QUALITY ASSURANCE

A. Refrigerant Recovery Technician Qualifications: Certified by an EPA-approved certification program.

FA4608-16-R-0011

1.7 FIELD CONDITIONS

A. Owner will occupy portions of building immediately adjacent to selective demolition area.

Conduct selective demolition so Owner's operations will not be disrupted.

B. Conditions existing at time of inspection for bidding purpose will be maintained by Owner as far as practical.

1. Before selective demolition, Owner will remove the following items:

a. Ceiling fans and light kits.

C. Notify Architect of discrepancies between existing conditions and Drawings before proceeding with selective demolition.

D. Hazardous Materials: Hazardous materials may be encountered in the Work.

1. Provide lead testing to all suspected materials that will disturbed by work.

2. If suspected hazardous materials are encountered, do not disturb; immediately notify

Contracting officer. Hazardous materials will be removed by Owner under a separate contract.

E. Hazardous Materials: Hazardous materials are present in buildings and structures to be selectively demolished. A report on the presence of hazardous materials is on file for review and use. Examine report to become aware of locations where hazardous materials are present.

1. Hazardous material remediation is specified elsewhere in the Contract Documents.

2. Do not disturb hazardous materials or items suspected of containing hazardous materials except under procedures specified elsewhere in the Contract Documents.

F. Storage or sale of removed items or materials on-site is not permitted.

G. Utility Service: Maintain existing utilities indicated to remain in service and protect them against damage during selective demolition operations.

1. Maintain fire-protection facilities in service during selective demolition operations.

1.8 WARRANTY

A. Existing Warranties: Remove, replace, patch, and repair materials and surfaces cut or damaged during selective demolition, by methods and with materials so as not to void existing warranties.

PART 2 - PRODUCTS

2.1 PEFORMANCE REQUIREMENTS

A. Regulatory Requirements: Comply with governing EPA notification regulations before beginning selective demolition. Comply with hauling and disposal regulations of authorities having jurisdiction.

B. Standards: Comply with ANSI/ASSE A10.6 and NFPA 241.

FA4608-16-R-0011

PART 3 - EXECUTION

3.1 EXAMINATION

A. Verify that utilities have been disconnected and capped before starting selective demolition operations.

B. Survey existing conditions and correlate with requirements indicated to determine extent of selective demolition required.

C. When unanticipated mechanical, electrical, or structural elements that conflict with intended function or design are encountered, investigate and measure the nature and extent of conflict.

Promptly submit a written report to Architect.

D. Survey of Existing Conditions: Record existing conditions by use of preconstruction photographs.

1. Comply with requirements specified in Division 1 Section "Photographic Documentation."

3.2 UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS

A. Existing Services/Systems to Remain: Maintain services/systems indicated to remain and protect them against damage.

1. Comply with requirements for existing services/systems interruptions specified in Division 1 Section "Summary."

B. Existing Services/Systems to Be Removed, Relocated, or Abandoned: Locate, identify, disconnect, and seal or cap off indicated utility services and mechanical/electrical systems serving areas to be selectively demolished.

1. Building manager will arrange to shut off indicated services/systems when requested by Contractor.

2. Arrange to shut off indicated utilities with utility companies.

3. If services/systems are required to be removed, relocated, or abandoned, provide temporary services/systems that bypass area of selective demolition and that maintain continuity of services/systems to other parts of building.

4. Disconnect, demolish, and remove fire-suppression systems, plumbing, and HVAC systems, equipment, and components indicated to be removed.

a. Piping to Be Removed: Remove portion of piping indicated to be removed and cap or plug remaining piping with same or compatible piping material.

b. Piping to Be Abandoned in Place: Drain piping and cap or plug piping with same or compatible piping material.

c. Equipment to Be Removed: Disconnect and cap services and remove equipment.

d. Equipment to Be Removed and Reinstalled: Disconnect and cap services and remove, clean, and store equipment; when appropriate, reinstall, reconnect, and make equipment operational.

e. Equipment to Be Removed and Salvaged: Disconnect and cap services and remove equipment and deliver to Owner.

f. Ducts to Be Removed: Remove portion of ducts indicated to be removed and plug remaining ducts with same or compatible ductwork material.

FA4608-16-R-0011

g. Ducts to Be Abandoned in Place: Cap or plug ducts with same or compatible ductwork material.

C. Refrigerant: Remove refrigerant from mechanical equipment to be selectively demolished according to 40 CFR 82 and regulations of authorities having jurisdiction.

3.3 PREPARATION

A. Site Access and Temporary Controls: Conduct selective demolition and debris-removal operations to ensure minimum interference with roads, streets, walks, walkways, and other adjacent occupied and used facilities.

1. Comply with requirements for access and protection specified in Division 1 Section "Temporary Facilities and Controls."

B. Temporary Facilities: Provide temporary barricades and other protection required to prevent injury to people and damage to adjacent buildings and facilities to remain.

C. Temporary Shoring: Provide and maintain shoring, bracing, and structural supports as required to preserve stability and prevent movement, settlement, or collapse of construction and finishes to remain, and to prevent unexpected or uncontrolled movement or collapse of construction being demolished.

3.4 SELECTIVE DEMOLITION, GENERAL

A. General: Demolish and remove existing construction only to the extent required by new construction and as indicated. Use methods required to complete the Work within limitations of governing regulations and as follows:

1. Neatly cut openings and holes plumb, square, and true to dimensions required. Use cutting methods least likely to damage construction to remain or adjoining construction.

Use hand tools or small power tools designed for sawing or grinding, not hammering and chopping, to minimize disturbance of adjacent surfaces. Temporarily cover openings to remain.

2. Cut or drill from the exposed or finished side into concealed surfaces to avoid marring existing finished surfaces.

3. Do not use cutting torches until work area is cleared of flammable materials. At concealed spaces, such as duct and pipe interiors, verify condition and contents of hidden space before starting flame-cutting operations. Maintain portable fire-suppression devices during flame-cutting operations.

4. Locate selective demolition equipment and remove debris and materials so as not to impose excessive loads on supporting walls, floors, or framing.

5. Dispose of demolished items and materials promptly.

B. Removed and Salvaged Items:

1. Clean salvaged items.

2. Pack or crate items after cleaning. Identify contents of containers.

3. Store items in a secure area until delivery to Owner.

4. Transport items to Owner's storage area designated by Owner.

5. Protect items from damage during transport and storage.

C. Removed and Reinstalled Items:

FA4608-16-R-0011

1. Clean and repair items to functional condition adequate for intended reuse.

2. Pack or crate items after cleaning and repairing. Identify contents of containers.

3. Protect items from damage during transport and storage.

4. Reinstall items in locations indicated. Comply with installation requirements for new materials and equipment. Provide connections, supports, and miscellaneous materials necessary to make item functional for use indicated.

D. Existing Items to Remain: Protect construction indicated to remain against damage and soiling during selective demolition. When permitted by Architect, items may be removed to a suitable, protected storage location during selective demolition and reinstalled in their original locations after selective demolition operations are complete.

3.5 DISPOSAL OF DEMOLISHED MATERIALS

A. General: Except for items or materials indicated to be reused, salvaged, reinstalled, or otherwise indicated to remain Owner's property, remove demolished materials from Project site.

1. Do not allow demolished materials to accumulate on-site.

2. Remove and transport debris in a manner that will prevent spillage on adjacent surfaces and areas.

3. Remove debris from elevated portions of building by chute, hoist, or other device that will convey debris to grade level in a controlled descent.

4. Comply with requirements specified in Division 1 Section "Construction Waste

Management."

B. Burning: Do not burn demolished materials.

C. Disposal: Transport demolished materials off Owner's property and legally dispose of them.

3.6 CLEANING

A. Clean adjacent structures and improvements of dust, dirt, and debris caused by selective demolition operations. Return adjacent areas to condition existing before selective demolition operations began.

END OF SECTION 01732

FA4608-16-R-0011

SECTION 02935 - ESTABLISHING TURF

1. SCOPE.

1.1 The work covered by this section of the specifications consists of furnishing all plant, labor, equipment, appliances, and materials, and in performing all operation in connection with seeding, sodding, mulching, fertilizing and watering, complete, in strict accordance with this section of the specifications and the applicable drawings, and subject to the terms and conditions of the contract.

2. SUBMITTALS.

2.1 Certificates of Conformance or Compliance. Before delivery, certificates attesting that the following materials meet the requirements specified, shall be submitted in duplicate:

Seed Fertilizer

2.2 Manufacturer's Literature. Manufacturer's literature on the following materials shall be submitted:

Hydro-Mulch Hydroseeding Machinery

3. MATERIALS:

3.1 Seed. Shall be state-certified seed of the latest season's crop and shall be delivered in original sealed packages bearing the producer's guaranteed analysis for percentages of mixtures, purity, germination, weed-seed content, and inert material. Seed shall be labeled in conformance with U.S. Department of Agriculture rules and regulations under the Federal Seed Act and applicable state seed laws. Seed that has become wet, moldy, or otherwise damaged will not be acceptable.

3.2 Sod. Shall be predominately Centipede nursery grown or natural field sod.

3.3 Topsoil. Shall be the existing surface soil stripped and stockpiled on the site.

3.4 If additional topsoil is required, it shall be furnished by the Contractor from approved sources off the site and shall be a natural, friable soil representative of productive soils in the vicinity.

It shall be obtained from well-drained areas and shall be free of admixture of subsoil and foreign matter or objects larger than one inch in any dimension, toxic substances, and any material or substance that may be harmful to plant growth. The pH range shall be 5.3 to 6.0.

Topsoil that does not meet this pH range shall be amended by the addition of lime.

3.5 Fertilizer: Shall be commercial grade 8-8-8, free flowing, uniform in composition and shall conform to applicable state and federal regulations.

3.6 Mulch:

1. Straw shall be stalks from oats, wheat, rye, barley, or rice that are free from noxious weeds, mold, or other objectionable material. Straw shall be in an air-dry condition and suitable for placing with blower equipment.

2. Hay shall be of herbaceous mowings, free from noxious weeds, mold, or other objectionable material. Hay shall be in an air-dry condition and suitable for placing with blower equipment.

3. Wood cellulose fiber for use with hydraulic application of grass seed and fertilizer shall consist of specially prepared wood cellulose fiber, processed to contain no growth or germination-inhibiting factors and dyed an appropriate color to facilitate visual metering of the application of materials. On an air-dry weight basis, the wood cellulose fiber shall contain a maximum of 12 percent moisture, plus or minus three percent at the time of manufacture. The pH range shall be from 3.5 to

5.0. The wood cellulose fiber shall be manufactured so that:

3.7 Mulch:

1. After addition and agitation in slurry tanks with fertilizers, grass seeds, water, and other approved additives, the fibers in the material will become uniformly suspended to form a homogeneous slurry.

2. When hydraulically sprayed on the ground the material will form a blotterlike cover impregnated uniformly with grass seed.

3. The cover will allow the absorption of moisture and allow rainfall or applied water to percolate to the underlaying soil.

4. DELIVERY AND STORAGE.

4.1 Delivery. The Contractor shall notify the Engineer of the delivery schedule in advance so material may be inspected upon arrival at the job site. Unacceptable material shall be removed from the job site immediately.

4.2 Fertilizer shall be delivered to the site in the original, unopened containers bearing the manufacturer's guaranteed chemical analysis, name, trade name, trademark, and conformance to state and federal laws. In lieu of containers, fertilizer may be furnished in bulk and a certificate indicating the above information shall accompany each delivery.

4.3 Storage. Seed, and fertilizer shall be kept in dry storage away from contaminants.

5. PLACING TOPSOIL.

5.1 Topsoil shall be distributed uniformly and spread evenly to a minimum thickness of 2 inches.

Topsoil shall be spread so that planting can proceed with little additional soil preparation or additional soil preparation or additional tillage. Surface irregularities resulting from topsoiling or other operations shall be leveled to prevent depressions. Grade shall be adjusted to assure that planted grade will be 1 inch below adjoining grade of any surfaced area. Topsoil shall not be placed when the subgrade is frozen, excessively wet, extremely dry, excessively compacted, or in a condition detrimental to the proposed planting or grading. Soil compacted construction equipment or soil on compacted cut slopes of grades shall be pulverized to a minimum depth of 2 inches by disking or plowing before applying topsoil.

6. PREPARATION OF SEED BED.

6.1 The seed bed shall be prepared by breaking, disking, harrowing, blading, dragging or other approved methods. The soil shall be thoroughly pulverized to a minimum depth of approximately 3 inches and leveled as directed. The surface soil shall be firmed by lightly

FA4608-16-R-0011

rolling the area with a cultipacker. If natural firming by rain has occurred, the rolling may be eliminated. All sticks, debris, and other foreign matter must be removed and the soil left in a suitable horticultural condition to receive the seed. Fertilizer shall be spread over the areas and incorporated into the soil during the preparation of the seed bed. Should erosion control measures become necessary, the Contractor shall furnish such protection as is required at his own expense.

7. SEEDING.

7.1 Centipede grass seed shall be broadcast at the rate of 30 pounds per acre either by hand crank seeders or with the approved hydraulic equipment in combination with wood cellulose fiber mulch and fertilizer as specified hereinbefore, or with other approved sowing equipment.

Seed shall be distributed uniformly over designated areas. Half of seed shall be sown with sower moving in one direction, and the remainder with sower moving at right angles to first sowing. Seed shall be covered to an average depth of 1/4 inches by brush harrow, spike-tooth harrow, chain harrow, cultipacker, hand rake with wood tines, or other approved device. Seed shall not be broadcast during windy weather.

8. FERTILIZING.

8.1 Fertilizer shall be applied at the rate of 1000 pounds per acre based upon the application of type 8-8-8 fertilizer. Fertilizer used shall be in accordance with requirements of the Louisiana Department of Agriculture, Fertilizer Division.

9. MULCHING.

9.1 Mulch shall be spread uniformly in a continuous blanket, using 1-1/2 tons per acre. Mulch shall be spread by hand or by a blower-type mulch spreader or other suitable equipment.

Mulching shall be started at the windward side of relatively flat areas, or at the upper part of a steep slope, and continued uniformly until the area is covered. The mulch shall be anchored to the soil by a V-type-wheel, or other suitable equipment, or by strings and stakes. Asphalt adhesive may be used with approval of the Engineer. Wood cellulose fiber mulch for use with the hydraulic application of seed and fertilizer shall be applied at the rate of 1400 pounds per acre.

10. SODDING.

10.1 Sodding shall be placed where indicated on the drawings. After the sodding operation has been completed, the edges of the sodded area shall blend smoothly into the surrounding area.

11. ESTABLISHMENT OF GRASS GROWTH.

11.1 The Contractor shall be responsible for the establishment of a satisfactory grass growth on the seeded areas and shall protect and maintain such grass growth, including watering and mowing until final acceptance of all the work to be performed under this contract. All watering and any re-seeding necessary to establish a satisfactory grass growth over all areas shall be done by and at the expense of the Contractor. Final acceptance will not be made until a satisfactory grass growth has been established.

11.2 If weeds or other vegetation growth to a height that they threaten to smother the plant species, they shall be mowed, raked, and removed from the area. When the surface of any part of an area which has been planted is gullied or otherwise damaged, the affected portions shall be repaired to re-establish the condition and grade of the soil prior to the injury and then re-seeded by and at the expense of the Contractor.

FA4608-16-R-0011

12. WATERING.

12.1 After the seed has been planted, the area shall be watered immediately with approved watering tanks unless, in the opinion of the engineer, there is sufficient moisture to eliminate watering. After the first watering operation other waterings will follow as directed. These watering operations will continue as necessary until the project is finally accepted. The water for seeding purposes shall be obtained from an approved source.

13. COMPLETION.

13.1 If all other work is completed, with the exception of the establishment of a satisfactory grass growth, partial acceptance of the work will be made with final acceptance delayed until a satisfactory grass growth has been established. Liquidated damages will not be assessed against the Contractor during the interim period between the date of such partial acceptance and the date of final acceptance if such delay is the result of seasonal limitations.

END OF SECTION 02935

SECTION 05500 - METAL FABRICATIONS

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section.

1.2 SUMMARY

A. This Section includes the following:

1. Steel framing and supports for ceiling-hung toilet compartments.

2. Steel framing and supports for operable partitions.

3. Steel framing and supports for overhead doors.

4. Steel framing and supports for countertops.

5. Steel framing and supports for mechanical and electrical equipment.

6. Steel framing and supports for applications where framing and supports are not specified in other Sections.

7. Elevator hoist beams.

8. Support angles for elevator door sills.

9. Shelf angles.

10. Loose bearing and leveling plates.

11. Steel weld plates and angles for casting into concrete not specified in other Sections.

12. Metal ladders.

13. Ladder safety cages.

14. Metal bollards.

15. Pipe guards.

16. Bicycle racks.

17. Metal floor plate and supports.

18. Abrasive metal nosings, treads, and thresholds.

19. Metal downspout boots.

B. Products furnished, but not installed, under this Section include the following:

1. Loose steel lintels.

2. Steel pipe sleeves, indicated to be cast into concrete or built into unit masonry.

C. Related Sections include the following:

1. Division 3 Section "Cast-in-Place Concrete" for installing anchor bolts, steel pipe sleeves, wedge-type inserts and other items indicated to be cast into concrete.

2. Division 5 Section "Structural Steel."

3. Division 5 Section "Metal Stairs."

4. Division 5 Section "Pipe and Tube Railings."

5. Division 14 Section "Hydraulic Elevators" for elevator pit ladders and support angles for elevator door sills.

FA4608-16-R-0011

1.3 PERFORMANCE REQUIREMENTS

A. Structural Performance of Ladders: Provide ladders capable of withstanding the effects of loads and stresses within limits and under conditions specified in ANSI A14.3.

B. Thermal Movements: Provide exterior metal fabrications that allow for thermal movements resulting from the following maximum change (range) in ambient and surface temperatures by preventing buckling, opening of joints, overstressing of components, failure of connections, and other detrimental effects. Base engineering calculation on surface temperatures of materials due to both solar heat gain and nighttime-sky heat loss.

1. Temperature Change (Range): 120 deg F, ambient; 180 deg F, material surfaces.

1.4 SUBMITTALS

A. Product Data: For the following:

1. Metal nosings and treads.

2. Paint products.

3. Grout.

B. Shop Drawings: Show fabrication and installation details for metal fabrications.

1. Include plans, elevations, sections, and details of metal fabrications and their connections. Show anchorage and accessory items.

2. Provide templates for anchors and bolts specified for installation under other Sections.

3. For installed products indicated to comply with design loads, include structural analysis data signed and sealed by the qualified professional engineer responsible for their preparation.

C. Samples for Verification: For each type and finish of extruded nosing and tread.

D. Mill Certificates: Signed by manufacturers of stainless-steel sheet certifying that products furnished comply with requirements.

E. Welding certificates.

F. Qualification Data: For professional engineer.

G. LEED Submittals:

Product Data for Credit MR 4.1: Indicating percentages by weight of postconsumer and pre-consumer recycled content for products having recycled content. Include statement indicating costs for each product having recycled content.

1.5 QUALITY ASSURANCE

A. Welding: Qualify procedures and personnel according to the following:

1. AWS D1.1, "Structural Welding Code--Steel."

2. AWS D1.3, "Structural Welding Code--Sheet Steel."

FA4608-16-R-0011

1.6 PROJECT CONDITIONS

A. Field Measurements: Verify actual locations of walls and other construction contiguous with metal fabrications by field measurements before fabrication and indicate measurements on Shop Drawings.

1. Established Dimensions: Where field measurements cannot be made without delaying the Work, establish dimensions and proceed with fabricating metal fabrications without field measurements. Coordinate wall and other contiguous construction to ensure that actual dimensions correspond to established dimensions.

2. Provide allowance for trimming and fitting at site.

1.7 COORDINATION

A. Coordinate installation of anchorages for metal fabrications. Furnish setting drawings, templates, and directions for installing anchorages, including sleeves, concrete inserts, anchor bolts, and items with integral anchors, that are to be embedded in concrete or masonry. Deliver such items to Project site in time for installation.

B. Coordinate installation of steel weld plates and angles for casting into concrete that are specified in this Section but required for work of another Section. Deliver such items to Project site in time for installation.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. In other Part 2 articles where titles below introduce lists, the following requirements apply to product selection:

1. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, products specified.

2. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, manufacturers specified.

2.2 METALS, GENERAL

A. Metal Surfaces, General: Provide materials with smooth, flat surfaces, unless otherwise indicated. For metal fabrications exposed to view in the completed Work, provide materials without seam marks, roller marks, rolled trade names, or blemishes.

2.3 FERROUS METALS

A. Steel Plates, Shapes, and Bars: ASTM A 36/A 36M.

B. Rolled-Steel Floor Plate: ASTM A 786/A 786M, rolled from plate complying with ASTM A 36/A 36M or ASTM A 283/A 283M, Grade C or D.

FA4608-16-R-0011

C. Steel Tubing: ASTM A 500, cold-formed steel tubing.

D. Steel Pipe: ASTM A 53/A 53M, standard weight (Schedule 40), unless another weight is indicated or required by structural loads.

2.4 FASTENERS

A. General: Unless otherwise indicated, provide Type 316 stainless-steel fasteners for exterior use and zinc-plated fasteners with coating complying with ASTM B 633, Class Fe/Zn 5, at exterior walls. Provide stainless-steel fasteners for fastening aluminum. Select fasteners for type, grade, and class required.

B. Steel Bolts and Nuts: Regular hexagon-head bolts, ASTM A 307, Grade A; with hex nuts, ASTM A 563; and, where indicated, flat washers.

C. Stainless-Steel Bolts and Nuts: Regular hexagon-head annealed stainless-steel bolts, nuts and, where indicated, flat washers; ASTM F 593 for bolts and ASTM F 594 for nuts, Alloy Group 1.

D. Anchor Bolts: ASTM F 1554, Grade 36.

1. Provide hot-dip or mechanically deposited, zinc-coated anchor bolts where item being fastened is indicated to be galvanized.

E. Eyebolts: ASTM A 489.

F. Machine Screws: ASME B18.6.3.

G. Plain Washers: Round, ASME B18.22.1.

H. Lock Washers: Helical, spring type, ASME B18.21.1.

I. Cast-in-Place Anchors in Concrete: Anchors capable of sustaining, without failure, a load equal to four times the load imposed, as determined by testing according to ASTM E 488, conducted by a qualified independent testing agency.

1. Threaded or wedge type; galvanized ferrous castings, either ASTM A 47/A 47M malleable iron or ASTM A 27/A 27M cast steel. Provide bolts, washers, and shims as needed, hot-dip galvanized per ASTM A 153/A 153M.

J. Expansion Anchors: Anchor bolt and sleeve assembly with capability to sustain, without failure, a load equal to six times the load imposed when installed in unit masonry and four times the load imposed when installed in concrete, as determined by testing according to ASTM E 488, conducted by a qualified independent testing agency.

1. Material for Anchors in Interior Locations: Carbon-steel components zinc-plated to comply with ASTM B 633, Class Fe/Zn 5.

2. Material for Anchors in Exterior Locations: Alloy Group 1 stainless-steel bolts complying with ASTM F 593 and nuts complying with ASTM F 594.

FA4608-16-R-0011

2.5 MISCELLANEOUS MATERIALS

A. Welding Rods and Bare Electrodes: Select according to AWS specifications for metal alloy welded.

B. Universal Shop Primer: Fast-curing, lead- and chromate-free, universal modified-alkyd primer complying with MPI#79.

C. Galvanizing Repair Paint: High-zinc-dust-content paint for regalvanizing welds in steel, complying with SSPC-Paint 20.

D. Bituminous Paint: Cold-applied asphalt emulsion complying with ASTM D 1187.

E. Nonshrink, Nonmetallic Grout: Factory-packaged, nonstaining, noncorrosive, nongaseous grout complying with ASTM C 1107. Provide grout specifically recommended by manufacturer for interior and exterior applications.

F. Concrete Materials and Properties: Comply with requirements in Division 3 Section "Cast-in- Place Concrete" for normal-weight, air-entrained, ready-mix concrete with a minimum 28-day compressive strength of 3000 psi, unless otherwise indicated.

2.6 FABRICATION, GENERAL

A. Shop Assembly: Preassemble items in the shop to greatest extent possible. Disassemble units only as necessary for shipping and handling limitations. Use connections that maintain structural value of joined pieces. Clearly mark units for reassembly and coordinated installation.

B. Cut, drill, and punch metals cleanly and accurately. Remove burrs and ease edges to a radius of approximately 1/32 inch, unless otherwise indicated. Remove sharp or rough areas on exposed surfaces.

C. Form bent-metal corners to smallest radius possible without causing grain separation or otherwise impairing work.

D. Form exposed work true to line and level with accurate angles and surfaces and straight edges.

E. Weld corners and seams continuously to comply with the following:

1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.

2. Obtain fusion without undercut or overlap.

3. Remove welding flux immediately.

4. At exposed connections, finish exposed welds and surfaces smooth and blended so no roughness shows after finishing and contour of welded surface matches that of adjacent surface.

F. Form exposed connections with hairline joints, flush and smooth, using concealed fasteners where possible. Where exposed fasteners are required, use Phillips flat-head (countersunk) screws or bolts, unless otherwise indicated. Locate joints where least conspicuous.

G. Fabricate seams and other connections that will be exposed to weather in a manner to exclude water. Provide weep holes where water may accumulate.

FA4608-16-R-0011

H. Cut, reinforce, drill, and tap metal fabrications as indicated to receive finish hardware, screws, and similar items.

I. Provide for anchorage of type indicated; coordinate with supporting structure. Space anchoring devices to secure metal fabrications rigidly in place and to support indicated loads.

1. Where units are indicated to be cast into concrete or built into masonry, equip with integrally welded steel strap anchors, 1/8 by 1-1/2 inches, with a minimum 6-inch embedment and 2-inch hook, not less than 8 inches from ends and corners of units and 24 inches o.c., unless otherwise indicated.

2.7 MISCELLANEOUS FRAMING AND SUPPORTS

A. General: Provide steel framing and supports not specified in other Sections as needed to complete the Work.

B. Fabricate units from steel shapes, plates, and bars of welded construction, unless otherwise indicated. Fabricate to sizes, shapes, and profiles indicated and as necessary to receive adjacent construction retained by framing and supports. Cut, drill, and tap units to receive hardware, hangers, and similar items.

1. Fabricate units from slotted channel framing where indicated.

2. Furnish inserts if units are installed after concrete is placed.

C. Fabricate supports for operable partitions from continuous steel beams of sizes indicated with attached bearing plates, anchors, and braces as indicated. Drill bottom flanges of beams to receive partition track hanger rods; locate holes where indicated on operable partition Shop Drawings.

D. Galvanize miscellaneous framing and supports where indicated.

E. Prime miscellaneous framing and supports with zinc-rich primer where indicated.

2.8 LOOSE STEEL LINTELS

A. Fabricate loose steel lintels from steel angles and shapes of size indicated for openings and recesses in masonry walls and partitions at locations indicated. Weld adjoining members together to form a single unit where indicated.

B. Size loose lintels to provide bearing length at each side of openings equal to 1/12 of clear span but not less than 8 inches, unless otherwise indicated.

C. Galvanize loose steel lintels located in exterior walls.

D. Prime loose steel lintels located in exterior walls with zinc-rich primer.

2.9 SHELF ANGLES

A. Fabricate shelf angles from steel angles of sizes indicated and for attachment to concrete framing. Provide horizontally slotted holes to receive 3/4-inch bolts, spaced not more than 6 inches from ends and 24 inches o.c., unless otherwise indicated.

FA4608-16-R-0011

1. Provide mitered and welded units at corners.

2. Provide open joints in shelf angles at expansion and control joints. Make open joint approximately 2 inches larger than expansion or control joint.

B. For cavity walls, provide vertical channel brackets to support angles from backup masonry and concrete.

C. Prime shelf angles located in exterior walls with zinc-rich primer.

D. Furnish wedge-type concrete inserts, complete with fasteners, to attach shelf angles to cast-in-place concrete.

2.10 LOOSE BEARING AND LEVELING PLATES

A. Provide loose bearing and leveling plates for steel items bearing on masonry or concrete construction. Drill plates to receive anchor bolts and for grouting.

B. Galvanize plates after fabrication.

C. Prime plates with zinc-rich primer.

2.11 STEEL WELD PLATES AND ANGLES

A. Provide steel weld plates and angles not specified in other Sections, for items supported from concrete construction as needed to complete the Work. Provide each unit with not less than two integrally welded steel strap anchors for embedding in concrete.

2.12 MISCELLANEOUS STEEL TRIM

A. Unless otherwise indicated, fabricate units from steel shapes, plates, and bars of profiles shown with continuously welded joints and smooth exposed edges. Miter corners and use concealed field splices where possible.

B. Provide cutouts, fittings, and anchorages as needed to coordinate assembly and installation with other work.

1. Provide with integrally welded steel strap anchors for embedding in concrete or masonry construction.

C. Prime exterior miscellaneous steel trim and interior miscellaneous steel trim, where indicated with zinc-rich primer.

2.13 METAL LADDERS

A. General:

1. Comply with ANSI A14.3, unless otherwise indicated.

2. For elevator pit ladders, comply with ASME A17.1.

3. Space siderails 18 inches apart, unless otherwise indicated.

FA4608-16-R-0011

4. Support each ladder at top and bottom and not more than 60 inches o.c. with welded or bolted brackets, made from same metal as ladder.

B. Steel Ladders:

1. Siderails: Continuous, 3/8-by-2-1/2-inch steel flat bars, with eased edges.

2. Rungs: 3/4-inch- diameter steel bars.

3. Fit rungs in centerline of siderails; plug-weld and grind smooth on outer rail faces.

4. Provide nonslip surfaces on top of each rung, either by coating rung with aluminum-oxide granules set in epoxy-resin adhesive or by using a type of manufactured rung filled with aluminum-oxide grout.

5. Provide nonslip surfaces on top of each rung by coating with abrasive material metallically bonded to rung by a proprietary process.

6. Available Products:

a. IKG Industries, a Harsco company; Mebac.

b. W. S. Molnar Company; SlipNOT.

7. Prime exterior ladders and interior ladders, where indicated, including brackets and fasteners, with zinc-rich primer.

C. Aluminum Ladders:

1. Siderails: Continuous extruded-aluminum channels or tubes, not less than 2-1/2 inches deep, 3/4 inch wide, and 1/8 inch thick.

2. Rungs: Extruded-aluminum tubes, not less than 3/4 inch deep and not less than 1/8 inch thick, with ribbed tread surfaces.

3. Fit rungs in centerline of siderails; fasten by welding or with stainless-steel fasteners or brackets and aluminum rivets.

2.14 METAL BOLLARDS

A. Fabricate metal bollards from Schedule 80 steel pipe.

1. Cap bollards with 1/4-inch- thick steel plate.

2. Where bollards are indicated to receive push-button controls for door operators, provide necessary cutouts for push-button controls and hole for wire.

B. Fabricate bollards with 3/8-inch- thick steel baseplates for bolting to concrete slab. Drill baseplates at all 4 corners for 3/4-inch anchor bolts.

1. Where bollards are to be anchored to sloping concrete slabs, angle baseplates for plumb alignment of bollards.

C. Fabricate sleeves for bollard anchorage from steel pipe or tubing with 1/4-inch- thick steel plate welded to bottom of sleeve. Make sleeves not less than 8 inches deep and 3/4 inch larger than OD of bollard.

D. Fabricate internal sleeves for removable bollards from Schedule 40 steel pipe or 1/4-inch wall-thickness steel tubing with an OD approximately 1/16 inch less than ID of bollards. Match drill sleeve and bollard for 3/4 inch steel machine bolt.

FA4608-16-R-0011

2.15 PIPE GUARDS

A. Fabricate pipe guards from 3/8-inch- thick by 12-inch- wide steel plate, bent to fit flat against the wall or column at both ends and to fit around pipe with 2-inch clearance between pipe and pipe guard. Drill each end for two 3/4-inch anchor bolts.

B. Galvanize pipe guards after fabrication.

2.16 BICYCLE RACKS

A. Fabricate from Schedule 40 steel pipe, fully welded together, to lengths indicated.

B. Fabricate with NPS 3 top rails and end posts, NPS 1-1/2 bottom rails and intermediate posts not more than 72 inches o.c., and NPS 3/4 vertical separators at approximately 8 inches o.c.

C. Make top rails 36 inches above pavement/floor and bottom rails 4 inches above pavement/floor.

D. Fabricate end posts and intermediate posts with 1/4-inch- thick steel baseplates for bolting to concrete slab. Drill end post baseplates at all 4 corners and intermediate-post baseplates at 2 opposite sides for 1/2-inch anchor bolts.

E. Galvanize bicycle racks after fabrication.

2.17 ABRASIVE METAL NOSINGS, TREADS, AND THRESHOLDS

A. Cast-Metal Units: Cast gray iron, Class 20, with an integral abrasive finish consisting of aluminum oxide, silicon carbide, or a combination of both. Fabricate units in sizes and configurations indicated and in lengths necessary to accurately fit openings or conditions.

1. Available Manufacturers:

a. American Safety Tread Co., Inc.

b. Balco Inc.

c. Barry Pattern & Foundry Co., Inc.

d. Granite State Casting Co.

e. Safe-T-Metal Co.

f. Wooster Products Inc.

2. Nosings: Cross-hatched units, 4 inches wide with 1-inch lip, for casting into concrete steps.

3. Nosings: Cross-hatched units, 1-1/2 by 1-1/2 inches, for casting into concrete curbs.

4. Treads: Cross-hatched units, full depth of tread with 3/4-by-3/4-inch nosing, for application over bent plate treads or existing stairs.

5. Thresholds: Plain-stepped- (stop-) type units, 5 inches wide by 1/2 inch high, with 1/2-inch step.

B. Extruded Units: Aluminum, with abrasive filler consisting of aluminum oxide, silicon carbide, or a combination of both, in an epoxy-resin binder. Fabricate units in sizes and configurations indicated and in lengths necessary to accurately fit openings or conditions.

1. Available Manufacturers:

FA4608-16-R-0011

a. ACL Industries, Inc.

b. American Safety Tread Co., Inc.

c. Amstep Products.

d. Armstrong Products, Inc.

e. Balco Inc.

f. Granite State Casting Co.

g. Wooster Products Inc.

2. Provide ribbed units, with abrasive filler strips projecting 1/16 inch above aluminum extrusion.

3. Provide solid-abrasive-type units without ribs.

4. Nosings: Square-back units, 4 inches wide, for casting into concrete steps.

5. Nosings: Beveled-back units, 4 inches wide with 1-3/8-inch lip, for surface mounting on existing stairs.

6. Nosings: Two-piece units, 3 inches wide, with subchannel for casting into concrete steps.

7. Treads: Square-back units, full depth of tread with 1-3/8-inch lip, for application over existing stairs.

C. Provide anchors for embedding units in concrete, either integral or applied to units, as standard with manufacturer.

D. Drill for mechanical anchors and countersink. Locate not more than 4 inches from ends and not more than 12 inches o.c., evenly spaced between ends, unless otherwise indicated. Provide closer spacing if recommended by manufacturer.

1. Provide 2 rows of holes for units more than 5 inches wide, with 2 holes aligned at ends and intermediate holes staggered.

E. Apply bituminous paint to concealed bottoms, sides, and edges of cast-metal units set into concrete.

F. Apply clear lacquer to concealed bottoms, sides, and edges of extruded units set into concrete.

2.18 METAL DOWNSPOUT BOOTS

A. Provide downspout boots made from cast gray iron in heights indicated with inlets of size and shape to suit downspouts.

1. Outlet: At 35 degrees from horizontal, to discharge onto splash block or pavement.

2.19 FINISHES, GENERAL

A. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes.

B. Finish metal fabrications after assembly.

FA4608-16-R-0011

2.20 STEEL AND IRON FINISHES

A. Galvanizing: Hot-dip galvanize items as indicated to comply with applicable standard listed below:

1. ASTM A 123/A 123M, for galvanizing steel and iron products.

2. ASTM A 153/A 153M, for galvanizing steel and iron hardware.

B. Preparation for Shop Priming: Prepare uncoated ferrous-metal surfaces to comply with minimum requirements indicated below for SSPC surface preparation specifications and environmental exposure conditions of installed metal fabrications:

1. Exteriors (SSPC Zone 1B) and Items Indicated to Receive Zinc-Rich Primer: SSPC- SP 6/NACE No. 3, "Commercial Blast Cleaning."

2. Interiors (SSPC Zone 1A): SSPC-SP 3, "Power Tool Cleaning."

C. Shop Priming: Apply shop primer to uncoated surfaces of metal fabrications, except those with galvanized finishes and those to be embedded in concrete, sprayed-on fireproofing, or masonry, unless otherwise indicated. Comply with SSPC-PA 1, "Paint Application Specification No. 1:

Shop, Field, and Maintenance Painting of Steel," for shop painting.

1. Stripe paint corners, crevices, bolts, welds, and sharp edges.

2.21 ALUMINUM FINISHES

A. Finish designations prefixed by AA comply with the system established by the Aluminum Association for designating aluminum finishes.

B. As-Fabricated Finish: AA-M10 (Mechanical Finish: as fabricated, unspecified).

C. Class I, Clear Anodic Finish: AA-M12C22A41 (Mechanical Finish: nonspecular as fabricated;

Chemical Finish: etched, medium matte; Anodic Coating: Architectural Class I, clear coating

0.018 mm or thicker) complying with AAMA 611.

PART 3 - EXECUTION

3.1 INSTALLATION, GENERAL

A. Cutting, Fitting, and Placement: Perform cutting, drilling, and fitting required for installing metal fabrications. Set metal fabrications accurately in location, alignment, and elevation; with edges and surfaces level, plumb, true, and free of rack; and measured from established lines and levels.

B. Fit exposed connections accurately together to form hairline joints. Weld connections that are not to be left as exposed joints but cannot be shop welded because of shipping size limitations.

Do not weld, cut, or abrade surfaces of exterior units that have been hot-dip galvanized after fabrication and are for bolted or screwed field connections.

C. Field Welding: Comply with the following requirements:

FA4608-16-R-0011

1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.

2. Obtain fusion without undercut or overlap.

3. Remove welding flux immediately.

4. At exposed connections, finish exposed welds and surfaces smooth and blended so no roughness shows after finishing and contour of welded surface matches that of adjacent surface.

D. Fastening to In-Place Construction: Provide anchorage devices and fasteners where metal fabrications are required to be fastened to in-place construction. Provide threaded fasteners for use with concrete and masonry inserts, toggle bolts, through bolts, lag bolts, wood screws, and other connectors.

E. Provide temporary bracing or anchors in formwork for items that are to be built into concrete, masonry, or similar construction.

F. Corrosion Protection: Coat concealed surfaces of aluminum that will come into contact with grout, concrete, masonry, wood, or dissimilar metals with a heavy coat of bituminous paint.

3.2 INSTALLING MISCELLANEOUS FRAMING AND SUPPORTS

A. General: Install framing and supports to comply with requirements of items being supported, including manufacturers' written instructions and requirements indicated on Shop…