Attachment__2_-_100__Drawings_NPTU_HVAC_dated_6_Aug_2015.pdf
PDF 16 MB Posted
- Attached to
- Repair HVAC, Training Support Facility, Bldg. 2314 (NPTU) Federal contract opportunity
- Solicitation number
- FA4418-15-R-0021
About this file
Attachment 2 - 100 Drawings NPTU HVAC dated 6 Aug 2015 for solicitation FA4418-15-R-0021
View the file
Other files for this federal contract opportunity
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
JOINT BASE CHARLESTON - WEAPONS STATION
REPAIR HVAC SYSTEM, TRAINING SUPPORT BUILDING
BUILDING 2314
PROJECT NO. DKGV 11-2314
100% SUBMITTAL
MECHANICAL ENGINEER:
RMF ENGINEERING
194 SEVEN FARMS DR.
CHARLESTON, SC 29492
843-971-9639
COVER SHEET
FIRST FLOOR CEILING DEMOLITION PLAN AREA A
A002
SHEET TITLE
SECOND FLOOR CEILING DEMOLITION PLAN AREA A
THIRD FLOOR CEILING DEMOLITION PLAN AREA A
FIRST FLOOR REFLECTED CEILING PLAN AREA A
SECOND FLOOR REFLECTED CEILING PLAN AREA A
PROJECT LOCATION
INDEX OF DRAWINGS
D111A
D112A
D113A
A111A
A112A
A001
A001
CO
VE
R
SH
EE
T
No.
1 57
ELECTRICAL LEGENDS AND SYMBOLS
ELECTRICAL DEMOLITION 1ST FLOOR PLAN AREA B
ED101A ELECTRICAL DEMOLITION 1ST FLOOR PLAN AREA A
ED101B
ED102A
ED102B
E001
ED103B
ELECTRICAL 1ST FLOOR PLAN AREA AE101A
E101B
ED103A
THIRD FLOOR REFLECTED CEILING PLAN AREA AA113A
REFLECTED CEILING PLAN SEISMIC DETAILSA114
ELECTRICAL DEMOLITION 2ND FLOOR PLAN AREA A
ELECTRICAL DEMOLITION 2ND FLOOR PLAN AREA B
ELECTRICAL DEMOLITION 3RD FLOOR PLAN AREA A
ELECTRICAL DEMOLITION 3RD FLOOR PLAN AREA B
ELECTRICAL 1ST FLOOR PLAN AREA B
ELECTRICAL 2ND FLOOR PLAN AREA A
ELECTRICAL 2ND FLOOR PLAN AREA B
E102A E102B
ELECTRICAL 3RD FLOOR PLAN AREA A
ELECTRICAL 3RD FLOOR PLAN AREA B
E103A
E103B
MECHANICAL 1ST FLOOR DEMOLITION PLAN AREA A
TITLESHEET
INDEX OF DRAWINGS
MD101A
MD101B
No.
M101A
HVAC DUCTWORK 1ST FLOOR PLAN AREA A
MD103A
MD103B
M101B HVAC DUCTWORK 1ST FLOOR PLAN AREA B
M102A HVAC DUCTWORK 2ND FLOOR PLAN AREA A
M102B HVAC DUCTWORK 2ND FLOOR PLAN AREA B
M103A HVAC DUCTWORK 3RD FLOOR PLAN AREA A
M103B HVAC DUCTWORK 3RD FLOOR PLAN AREA B
M301
M401
MECHANICAL DETAILS
MECHANICAL SCHEDULES
MECHANICAL 1ST FLOOR DEMOLITION PLAN AREA B
MECHANICAL 3RD FLOOR DEMOLITION PLAN AREA A
MECHANICAL 3RD FLOOR DEMOLITION PLAN AREA B
M201 MECHANICAL CONTROL DIAGRAMS AND SCHEMES
M202 MECHANICAL CONTROL DIAGRAMS AND SCHEMES
M203 MECHANICAL CONTROL DIAGRAMS AND SCHEMES
M204 MECHANICAL CONTROL DIAGRAMS AND SCHEMES
M302 MECHANICAL DETAILS
M303 MECHANICAL DETAILS
M402 MECHANICAL SCHEDULES
M403 MECHANICAL SCHEDULES
FIRST FLOOR CEILING DEMOLITION PLAN AREA B
SECOND FLOOR CEILING DEMOLITION PLAN AREA B
THIRD FLOOR CEILING DEMOLITION PLAN AREA B
FIRST FLOOR REFLECTED CEILING PLAN AREA B
SECOND FLOOR REFLECTED CEILING PLAN AREA B
D111B
D112B
D113B
A111B
A112B
THIRD FLOOR REFLECTED CEILING PLAN AREA BA113B
ELECTRICAL ENLARGED PLANSE201
MECHANICAL LEGENDS AND SYMBOLS
M002 MECHANICAL ABBREVIATIONS AND GENERAL NOTES
M001
MD102A
MD102B
MECHANICAL 2ND FLOOR DEMOLITION PLAN AREA A
MECHANICAL 2ND FLOOR DEMOLITION PLAN AREA B
PROJECT ARCHITECT:
STUBBS MULDROW HERIN ARCHITECTS, INC.
400 HIBBEN STREET, SUITE 100
MOUNT PLEASANT, SC 29464
843-881-7642
ELECTRICAL DEMOLITION SITE PLANED002
ELECTRICAL NEW WORK SITE PLANE002
M205 MECHANICAL CONTROL DIAGRAMS AND SCHEMES
MECHANICAL DETAILSM304
Attachment #2 FA4418-15-R-0021
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
100' x 45' LAY
DOWN AREA
HAUL ROUTE
SITE
SOUTH GATE
ENTRY: POINT
OF INSPECTION
HAUL ROUTE
SITE
NWS
CHARLESTON
GEORGETOWN
ATLA
NTIC
O
CEANGEORGIA
SAVANNAH
ORANGEBURG
COLUMBIA
AUGUSTA
95 17
GREENVILLE
SPARTANBURG
FLORENCE
CHARLOTTE
WILMINGTON
BEAUFORT
SUMTER
178 NORTH
MYRTLE BEACH
NORTH CAROLINA
SCALE: 1"=40 MILES
VICINITY MAP - SOUTH CAROLINA
SCALE: 1"=2.5 MILES
LOCATION MAP - CHARLESTON, SC
PROJECT
LOCATION
70117
17 MT. P
LEASANT
JA
MES IS
LAND
CHARLESTON
CHARLESTON
NORTH
CHARLESTON
HARBOR
CA
IN
HO
Y
RD
BEES FERRY RD
ASHLE
Y R
IV
ER R
D
SAVANNAH HWY
STONO
RIVER
CO
O
PE
R
RIVER
AS
H
LE
Y
RI
VE
R
MONTAGUE AVE
REMOUNT RD
R
IV
ER
S
AV
E
MARK CLARK EXPY
DO
RC
HE
ST
ER
R
D
AVIATION AVE
ASHLEY PHOSPHATE RD
JO
INT BASE
CHARLESTON-
AIR
RED BANK RD
N R
H E
TT
A
V
E NAVAL
WEAPONS
STATION
A002
PR
OJ
EC
T L
OC
AT
IO
N
2 57
OLD TOM
RD.
O
LD
T O
M R
D
OLD
TOM R
D
BLDG 2314
BUILDING LOCATION MAP
PARKING
PARKING
COOPER RIVER
SCALE: 1" = 800'
LAY DOWN AREA
SCALE: 1" = 250'
B2314
SCALE: 1" = 2000'
CONTRACTOR HAUL ROUTE
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
1xx1xx
1XX
1xx
117A
119 117B
113A
126A
1261XX
112C112B112A
112D
1xx
130 1
MATCH LINE MATCH LINE
GENERAL NOTES :
A. THIS DRAWING SHOWS THE GENERAL EXTENT OF SELECTIVE
DEMOLITION. ALL CEILINGS DASHED ARE TO BE REMOVED.
LIGHTS TO BE REMOVED AND REINSTALLED IN NEW CEILING
UNLESS NOTED OTHERWISE. REFER TO OTHER MECHANICAL
DEMOLITION PLANS FOR ADDITIONAL ITEMS TO BE REMOVED OR
RELOCATED.
B. IF THE WORK ABOVE THE CEILING CAN BE PERFORMED BY
SIMPLY REMOVING ACOUSTICAL CEILING TILE, WITHOUT
DAMAGE TO THE GRID, THEN NO CEILING REPLACEMENT IS
REQUIRED. SHOULD ANY REMOVED CEILING TILE BE DAMAGED,
IT MUST BE REPLACED WITH A NEW TILE OF THE EXACT BRAND,
STYLE AND COLOR.
C. IF THE WORK ABOVE THE CEILING REQUIRES THE
REPLACEMENT OF A COMPONENT, SUCH AS A VAV BOX OR A
SMALL AMOUNT OF DUCTWORK, BUT ONLY IMPACTS A SMALL
PORTION OF THE CEILING IN THE SUBJECT ROOM, THE
ARCHITECTURAL DRAWINGS WILL REFLECT A SELECT
DEMOLITION AND REPLACEMENT OF CEILING GRID AND
ACOUSTICAL CEILING TILE, MATCHING THE EXISTING IN EXACT
BRAND, STYLE AND COLOR. THERE ARE OCCASIONS WHERE
THIS LIMITED AMOUNT OF CEILING REPLACEMENT WILL REQUIRE
THAT FLUORESCENT LIGHT FIXTURES, HVAC DIFFUSERS AND
RETURNS, SPRINKLER HEAD ESCUTCHEONS, OR OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED. IN THESE INSTANCES,
THE CEILING IN THAT PARTICULAR ROOM NEED NOT BE
BROUGHT UP TO CURRENT SEISMIC CODES.
D. IF THE MECHANICAL SCOPE OF WORK IN A ROOM REQUIRES
THE REPLACEMENT OF HVAC COMPONENTS, VAV BOXES OR
DUCTWORK THAT IMPACTS A SIGNIFICANT PORTION OF THE
CEILING, A COMPLETE CEILING REPLACEMENT IN THAT SUBJECT
ROOM WILL BE INDICATED. WITH A COMPLETE CEILING
REPLACEMENT, THE CEILING WILL BE BROUGHT UP TO CURRENT
CODE IN REGARDS TO SEISMIC RESTRAINT. THIS WILL REQUIRE
ADDITIONAL SPLAY WIRES, FIXED RESTRAINT OF THE GRID AT
TWO ADJACENT WALLS AND 2 INCH WALL MOLD. COMPLETE
CEILING REPLACEMENT WILL REQUIRE THAT SUSPENDED
FLUORESCENT LIGHTS, HVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS AND ANY OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED WITH THE NEW CEILING
WITH REQUIRED SEISMIC RESTRAINT.
E. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS IN THE FIELD PRIOR TO UNDERTAKING ANY
DEMOLITION WORK. ANY DISCREPANCIES SHOULD BE
BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY.
F. THE CONTRACTOR SHALL SCHEDULE ALL WORK INCLUDING
ANY INTERRUPTION OF UTILITIES 30 DAYS PRIOR TO THE START
OF WORK. THE BUILDING SHALL BE OCCUPIED AND IN USE
DURING THE TIME THE WORK IS BEING PERFORMED.
CONTRACTOR MUST NOTIFY AND SCHEDULE INTERRUPTIONS
WITH THE OWNER OR MAINTAIN ACCESS TO AREAS OUTSIDE
THE SCOPE OF WORK AS REQUIRED BY OWNER.
G. MAINTAIN AND PROTECT ANY AND ALL ITEMS NOTED TO BE
REUSED AND/OR RELOCATED.
H. REFER TO MECHANICAL AND ELECTRICAL DEMOLITION
DRAWINGS FOR ADDITIONAL SCOPE. INCIDENTAL DEMOLITION
DUE TO MECHANICAL AND/OR ELECTRICAL DEMOLITION AND
NEW WORK SHALL BE INCLUDED IN CONTRACT AS WELL AS
REPAIR WORK REQUIRED TO RETURN FINISH SURFACE TO
ORIGINAL CONDITION.
I. CONTRACTOR SHALL REMOVE ALL UNNECESSARY OR
ABANDONED PIPING, CONDUIT AND WIRING THAT IS ACCESSIBLE
WITHOUT ADDITIONAL DEMOLITION.
J. CONTRACTOR SHALL FOLLOW PHASING OF THE WORK AS
INDICATED ON MECHANICAL DOCUMENTS.
K. ALL LIGHT FIXTURES IN AREAS WHERE CEILING IS TO BE
DEMOLISHED ARE TO BE TAKEN DOWN AND STORED. THEY ARE
TO BE REINSTALLED IN ORIGINAL LOCATION WHEN ALL WORK
ABOVE THE CEILING IS COMPLETE.
L. ALL CEILING WORK TO FOLLOW PHASING AND BADGING
REQUIREMENTS AS DESCRIBED IN MECHANICAL AND
ELECTRICAL DRAWINGS.
LEGEND:
EXISTING ACOUSTICAL TILE CEILING AND
GRID TO BE REMOVED
EXISTING GYPSUM BOARD CEILING TO BE
REMOVED
EXISTING SUPPLY AIR DIFFUSER TO BE
REMOVED
EXISTING RETURN AIR GRILLE TO BE
REINSTALLED IF REMOVED DURING
CEILING WORK
EXISTING SUPPLY AIR DIFFUSER TO BE
REINSTALLED IF REMOVED DURING CEILING
WORK
N
NO WORK
N
8 4 0 8 16
KEY PLAN
A
B
DEMOLITION NOTES:
REMOVE PORTION OF CEILING - SEE GENERAL NOTE
C.
REMOVE AND REINSTALL CEILING MOUNTED
SPEAKERS IN ORIGINAL LOCATION ONCE CEILING
TILES ARE REINSTALLED.
REMOVE TILE AROUND PROJECTOR AND CUT NEW
TILE TO CLEANLY FIT AROUND PROJECTOR MOUNT.
SIMPLEX PLATE ON CEILING TILE TO BE
REINSTALLED ON NEW CEILING TILE IN ORIGINAL
LOCATION .
REMOVE AND REINSTALL CEILING MOUNTED
CAMERA IN ORIGINAL LOCATION ONCE CEILING
TILES ARE REINSTALLED.
THERE IS EQUIPMENT IN THIS ROOM THAT CANNOT
BE RELOCATED. IT IS TO BE PROTECTED DURING
DEMOLITION WORK.
SCALE:1/8" = 1'-0"
C1 FIRST FLOOR CEILING DEMOLITION PLAN
D111A
FIR
ST
FL
OO
R
CE
ILI
NG
D
EM
OL
ITI
ON
P
LA
N
AR
EA
A
3 57
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
HG
EDCBA
F
108A
VEND
VEND
108B
SEC MGR SEC OFCR
107C
107107A108C
104E 104D
104F
104B
106 105 110
1XX
112F
112E
112D
103A
104A
107B
2 5
MATCH LINE MATCH LINE
N
NO WORK
N
8 4 0 8 16
KEY PLAN
A
B
GENERAL NOTES :
A. THIS DRAWING SHOWS THE GENERAL EXTENT OF SELECTIVE
DEMOLITION. ALL CEILINGS DASHED ARE TO BE REMOVED.
LIGHTS TO BE REMOVED AND REINSTALLED IN NEW CEILING
UNLESS NOTED OTHERWISE. REFER TO OTHER MECHANICAL
DEMOLITION PLANS FOR ADDITIONAL ITEMS TO BE REMOVED OR
RELOCATED.
B. IF THE WORK ABOVE THE CEILING CAN BE PERFORMED BY
SIMPLY REMOVING ACOUSTICAL CEILING TILE, WITHOUT
DAMAGE TO THE GRID, THEN NO CEILING REPLACEMENT IS
REQUIRED. SHOULD ANY REMOVED CEILING TILE BE DAMAGED,
IT MUST BE REPLACED WITH A NEW TILE OF THE EXACT BRAND,
STYLE AND COLOR.
C. IF THE WORK ABOVE THE CEILING REQUIRES THE
REPLACEMENT OF A COMPONENT, SUCH AS A VAV BOX OR A
SMALL AMOUNT OF DUCTWORK, BUT ONLY IMPACTS A SMALL
PORTION OF THE CEILING IN THE SUBJECT ROOM, THE
ARCHITECTURAL DRAWINGS WILL REFLECT A SELECT
DEMOLITION AND REPLACEMENT OF CEILING GRID AND
ACOUSTICAL CEILING TILE, MATCHING THE EXISTING IN EXACT
BRAND, STYLE AND COLOR. THERE ARE OCCASIONS WHERE
THIS LIMITED AMOUNT OF CEILING REPLACEMENT WILL REQUIRE
THAT FLUORESCENT LIGHT FIXTURES, HVAC DIFFUSERS AND
RETURNS, SPRINKLER HEAD ESCUTCHEONS, OR OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED. IN THESE INSTANCES,
THE CEILING IN THAT PARTICULAR ROOM NEED NOT BE
BROUGHT UP TO CURRENT SEISMIC CODES.
D. IF THE MECHANICAL SCOPE OF WORK IN A ROOM REQUIRES
THE REPLACEMENT OF HVAC COMPONENTS, VAV BOXES OR
DUCTWORK THAT IMPACTS A SIGNIFICANT PORTION OF THE
CEILING, A COMPLETE CEILING REPLACEMENT IN THAT SUBJECT
ROOM WILL BE INDICATED. WITH A COMPLETE CEILING
REPLACEMENT, THE CEILING WILL BE BROUGHT UP TO CURRENT
CODE IN REGARDS TO SEISMIC RESTRAINT. THIS WILL REQUIRE
ADDITIONAL SPLAY WIRES, FIXED RESTRAINT OF THE GRID AT
TWO ADJACENT WALLS AND 2 INCH WALL MOLD. COMPLETE
CEILING REPLACEMENT WILL REQUIRE THAT SUSPENDED
FLUORESCENT LIGHTS, HVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS AND ANY OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED WITH THE NEW CEILING
WITH REQUIRED SEISMIC RESTRAINT.
E. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS IN THE FIELD PRIOR TO UNDERTAKING ANY
DEMOLITION WORK. ANY DISCREPANCIES SHOULD BE
BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY.
F. THE CONTRACTOR SHALL SCHEDULE ALL WORK INCLUDING
ANY INTERRUPTION OF UTILITIES 30 DAYS PRIOR TO THE START
OF WORK. THE BUILDING SHALL BE OCCUPIED AND IN USE
DURING THE TIME THE WORK IS BEING PERFORMED.
CONTRACTOR MUST NOTIFY AND SCHEDULE INTERRUPTIONS
WITH THE OWNER OR MAINTAIN ACCESS TO AREAS OUTSIDE
THE SCOPE OF WORK AS REQUIRED BY OWNER.
G. MAINTAIN AND PROTECT ANY AND ALL ITEMS NOTED TO BE
REUSED AND/OR RELOCATED.
H. REFER TO MECHANICAL AND ELECTRICAL DEMOLITION
DRAWINGS FOR ADDITIONAL SCOPE. INCIDENTAL DEMOLITION
DUE TO MECHANICAL AND/OR ELECTRICAL DEMOLITION AND
NEW WORK SHALL BE INCLUDED IN CONTRACT AS WELL AS
REPAIR WORK REQUIRED TO RETURN FINISH SURFACE TO
ORIGINAL CONDITION.
I. CONTRACTOR SHALL REMOVE ALL UNNECESSARY OR
ABANDONED PIPING, CONDUIT AND WIRING THAT IS ACCESSIBLE
WITHOUT ADDITIONAL DEMOLITION.
J. CONTRACTOR SHALL FOLLOW PHASING OF THE WORK AS
INDICATED ON MECHANICAL DOCUMENTS.
K. ALL LIGHT FIXTURES IN AREAS WHERE CEILING IS TO BE
DEMOLISHED ARE TO BE TAKEN DOWN AND STORED. THEY ARE
TO BE REINSTALLED IN ORIGINAL LOCATION WHEN ALL WORK
ABOVE THE CEILING IS COMPLETE.
L. ALL CEILING WORK TO FOLLOW PHASING AND BADGING
REQUIREMENTS AS DESCRIBED IN MECHANICAL AND
ELECTRICAL DRAWINGS.
LEGEND:
EXISTING ACOUSTICAL TILE CEILING AND
GRID TO BE REMOVED
EXISTING GYPSUM BOARD CEILING TO BE
REMOVED
EXISTING SUPPLY AIR DIFFUSER TO BE
REMOVED
EXISTING RETURN AIR GRILLE TO BE
REINSTALLED IF REMOVED DURING
CEILING WORK
EXISTING SUPPLY AIR DIFFUSER TO BE
REINSTALLED IF REMOVED DURING CEILING
WORK
DEMOLITION NOTES:
REMOVE PORTION OF CEILING - SEE GENERAL NOTE
C.
REMOVE AND REINSTALL CEILING MOUNTED
SPEAKERS IN ORIGINAL LOCATION ONCE CEILING
TILES ARE REINSTALLED.
REMOVE TILE AROUND PROJECTOR AND CUT NEW
TILE TO CLEANLY FIT AROUND PROJECTOR MOUNT.
SIMPLEX PLATE ON CEILING TILE TO BE
REINSTALLED ON NEW CEILING TILE IN ORIGINAL
LOCATION .
REMOVE AND REINSTALL CEILING MOUNTED
CAMERA IN ORIGINAL LOCATION ONCE CEILING
TILES ARE REINSTALLED.
THERE IS EQUIPMENT IN THIS ROOM THAT CANNOT
BE RELOCATED. IT IS TO BE PROTECTED DURING
DEMOLITION WORK.
SCALE:1/8" = 1'-0"
C1 FIRST FLOOR CEILING DEMOLITION PLAN
FIR
ST
FL
OO
R
CE
ILI
NG
D
EM
OL
ITI
ON
P
LA
N
AR
EA
B
4 57
D111B
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
212B
212C
212D
212E
212E(1)
212F 212G 212H 212I 212J 213
212K
212L
212M
212N
212O
212P
212Q
201B
201E
201D
STO
201J201I201H201G201F
201E
201L
201M
201N
201O
201T
201Q
201K
201212
214A
MATCH LINE MATCH LINE
N
NO WORK
N
8 4 0 8 16
KEY PLAN
A
B
GENERAL NOTES :
A. THIS DRAWING SHOWS THE GENERAL EXTENT OF SELECTIVE
DEMOLITION. ALL CEILINGS DASHED ARE TO BE REMOVED.
LIGHTS TO BE REMOVED AND REINSTALLED IN NEW CEILING
UNLESS NOTED OTHERWISE. REFER TO OTHER MECHANICAL
DEMOLITION PLANS FOR ADDITIONAL ITEMS TO BE REMOVED OR
RELOCATED.
B. IF THE WORK ABOVE THE CEILING CAN BE PERFORMED BY
SIMPLY REMOVING ACOUSTICAL CEILING TILE, WITHOUT
DAMAGE TO THE GRID, THEN NO CEILING REPLACEMENT IS
REQUIRED. SHOULD ANY REMOVED CEILING TILE BE DAMAGED,
IT MUST BE REPLACED WITH A NEW TILE OF THE EXACT BRAND,
STYLE AND COLOR.
C. IF THE WORK ABOVE THE CEILING REQUIRES THE
REPLACEMENT OF A COMPONENT, SUCH AS A VAV BOX OR A
SMALL AMOUNT OF DUCTWORK, BUT ONLY IMPACTS A SMALL
PORTION OF THE CEILING IN THE SUBJECT ROOM, THE
ARCHITECTURAL DRAWINGS WILL REFLECT A SELECT
DEMOLITION AND REPLACEMENT OF CEILING GRID AND
ACOUSTICAL CEILING TILE, MATCHING THE EXISTING IN EXACT
BRAND, STYLE AND COLOR. THERE ARE OCCASIONS WHERE
THIS LIMITED AMOUNT OF CEILING REPLACEMENT WILL REQUIRE
THAT FLUORESCENT LIGHT FIXTURES, HVAC DIFFUSERS AND
RETURNS, SPRINKLER HEAD ESCUTCHEONS, OR OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED. IN THESE INSTANCES,
THE CEILING IN THAT PARTICULAR ROOM NEED NOT BE
BROUGHT UP TO CURRENT SEISMIC CODES.
D. IF THE MECHANICAL SCOPE OF WORK IN A ROOM REQUIRES
THE REPLACEMENT OF HVAC COMPONENTS, VAV BOXES OR
DUCTWORK THAT IMPACTS A SIGNIFICANT PORTION OF THE
CEILING, A COMPLETE CEILING REPLACEMENT IN THAT SUBJECT
ROOM WILL BE INDICATED. WITH A COMPLETE CEILING
REPLACEMENT, THE CEILING WILL BE BROUGHT UP TO CURRENT
CODE IN REGARDS TO SEISMIC RESTRAINT. THIS WILL REQUIRE
ADDITIONAL SPLAY WIRES, FIXED RESTRAINT OF THE GRID AT
TWO ADJACENT WALLS AND 2 INCH WALL MOLD. COMPLETE
CEILING REPLACEMENT WILL REQUIRE THAT SUSPENDED
FLUORESCENT LIGHTS, HVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS AND ANY OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED WITH THE NEW CEILING
WITH REQUIRED SEISMIC RESTRAINT.
E. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS IN THE FIELD PRIOR TO UNDERTAKING ANY
DEMOLITION WORK. ANY DISCREPANCIES SHOULD BE
BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY.
F. THE CONTRACTOR SHALL SCHEDULE ALL WORK INCLUDING
ANY INTERRUPTION OF UTILITIES 30 DAYS PRIOR TO THE START
OF WORK. THE BUILDING SHALL BE OCCUPIED AND IN USE
DURING THE TIME THE WORK IS BEING PERFORMED.
CONTRACTOR MUST NOTIFY AND SCHEDULE INTERRUPTIONS
WITH THE OWNER OR MAINTAIN ACCESS TO AREAS OUTSIDE
THE SCOPE OF WORK AS REQUIRED BY OWNER.
G. MAINTAIN AND PROTECT ANY AND ALL ITEMS NOTED TO BE
REUSED AND/OR RELOCATED.
H. REFER TO MECHANICAL AND ELECTRICAL DEMOLITION
DRAWINGS FOR ADDITIONAL SCOPE. INCIDENTAL DEMOLITION
DUE TO MECHANICAL AND/OR ELECTRICAL DEMOLITION AND
NEW WORK SHALL BE INCLUDED IN CONTRACT AS WELL AS
REPAIR WORK REQUIRED TO RETURN FINISH SURFACE TO
ORIGINAL CONDITION.
I. CONTRACTOR SHALL REMOVE ALL UNNECESSARY OR
ABANDONED PIPING, CONDUIT AND WIRING THAT IS ACCESSIBLE
WITHOUT ADDITIONAL DEMOLITION.
J. CONTRACTOR SHALL FOLLOW PHASING OF THE WORK AS
INDICATED ON MECHANICAL DOCUMENTS.
K. ALL LIGHT FIXTURES IN AREAS WHERE CEILING IS TO BE
DEMOLISHED ARE TO BE TAKEN DOWN AND STORED. THEY ARE
TO BE REINSTALLED IN ORIGINAL LOCATION WHEN ALL WORK
ABOVE THE CEILING IS COMPLETE.
L. ALL CEILING WORK TO FOLLOW PHASING AND BADGING
REQUIREMENTS AS DESCRIBED IN MECHANICAL AND
ELECTRICAL DRAWINGS.
LEGEND:
EXISTING ACOUSTICAL TILE CEILING AND
GRID TO BE REMOVED
EXISTING GYPSUM BOARD CEILING TO BE
REMOVED
EXISTING SUPPLY AIR DIFFUSER TO BE
REMOVED
EXISTING RETURN AIR GRILLE TO BE
REINSTALLED IF REMOVED DURING
CEILING WORK
EXISTING SUPPLY AIR DIFFUSER TO BE
REINSTALLED IF REMOVED DURING CEILING
WORK
DEMOLITION NOTES:
REMOVE PORTION OF CEILING - SEE GENERAL NOTE
C.
REMOVE AND REINSTALL CEILING MOUNTED
SPEAKERS IN ORIGINAL LOCATION ONCE CEILING
TILES ARE REINSTALLED.
REMOVE TILE AROUND PROJECTOR AND CUT NEW
TILE TO CLEANLY FIT AROUND PROJECTOR MOUNT.
SIMPLEX PLATE ON CEILING TILE TO BE
REINSTALLED ON NEW CEILING TILE IN ORIGINAL
LOCATION .
REMOVE AND REINSTALL CEILING MOUNTED
CAMERA IN ORIGINAL LOCATION ONCE CEILING
TILES ARE REINSTALLED.
THERE IS EQUIPMENT IN THIS ROOM THAT CANNOT
BE RELOCATED. IT IS TO BE PROTECTED DURING
DEMOLITION WORK.
SCALE:1/8" = 1'-0"
C1 SECOND FLOOR CEILING DEMOLITION PLAN
D112A
SE
CO
ND
FL
OO
R
CE
ILI
NG
D
EM
OL
ITI
ON
P
LA
N
AR
EA
A
5 57
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
212A
212B
212P
212Q
201A
201B
201T
201Q
209A
209B
209D
209C209E
209G
209F
211A
208B
208A
208C
208E
208D
204A
204B
202 202A
203A
203B203C
203D
2 2
MATCH LINE MATCH LINE
N
NO WORK
N
8 4 0 8 16
KEY PLAN
A
B
GENERAL NOTES :
A. THIS DRAWING SHOWS THE GENERAL EXTENT OF SELECTIVE
DEMOLITION. ALL CEILINGS DASHED ARE TO BE REMOVED.
LIGHTS TO BE REMOVED AND REINSTALLED IN NEW CEILING
UNLESS NOTED OTHERWISE. REFER TO OTHER MECHANICAL
DEMOLITION PLANS FOR ADDITIONAL ITEMS TO BE REMOVED OR
RELOCATED.
B. IF THE WORK ABOVE THE CEILING CAN BE PERFORMED BY
SIMPLY REMOVING ACOUSTICAL CEILING TILE, WITHOUT
DAMAGE TO THE GRID, THEN NO CEILING REPLACEMENT IS
REQUIRED. SHOULD ANY REMOVED CEILING TILE BE DAMAGED,
IT MUST BE REPLACED WITH A NEW TILE OF THE EXACT BRAND,
STYLE AND COLOR.
C. IF THE WORK ABOVE THE CEILING REQUIRES THE
REPLACEMENT OF A COMPONENT, SUCH AS A VAV BOX OR A
SMALL AMOUNT OF DUCTWORK, BUT ONLY IMPACTS A SMALL
PORTION OF THE CEILING IN THE SUBJECT ROOM, THE
ARCHITECTURAL DRAWINGS WILL REFLECT A SELECT
DEMOLITION AND REPLACEMENT OF CEILING GRID AND
ACOUSTICAL CEILING TILE, MATCHING THE EXISTING IN EXACT
BRAND, STYLE AND COLOR. THERE ARE OCCASIONS WHERE
THIS LIMITED AMOUNT OF CEILING REPLACEMENT WILL REQUIRE
THAT FLUORESCENT LIGHT FIXTURES, HVAC DIFFUSERS AND
RETURNS, SPRINKLER HEAD ESCUTCHEONS, OR OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED. IN THESE INSTANCES,
THE CEILING IN THAT PARTICULAR ROOM NEED NOT BE
BROUGHT UP TO CURRENT SEISMIC CODES.
D. IF THE MECHANICAL SCOPE OF WORK IN A ROOM REQUIRES
THE REPLACEMENT OF HVAC COMPONENTS, VAV BOXES OR
DUCTWORK THAT IMPACTS A SIGNIFICANT PORTION OF THE
CEILING, A COMPLETE CEILING REPLACEMENT IN THAT SUBJECT
ROOM WILL BE INDICATED. WITH A COMPLETE CEILING
REPLACEMENT, THE CEILING WILL BE BROUGHT UP TO CURRENT
CODE IN REGARDS TO SEISMIC RESTRAINT. THIS WILL REQUIRE
ADDITIONAL SPLAY WIRES, FIXED RESTRAINT OF THE GRID AT
TWO ADJACENT WALLS AND 2 INCH WALL MOLD. COMPLETE
CEILING REPLACEMENT WILL REQUIRE THAT SUSPENDED
FLUORESCENT LIGHTS, HVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS AND ANY OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED WITH THE NEW CEILING
WITH REQUIRED SEISMIC RESTRAINT.
E. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS IN THE FIELD PRIOR TO UNDERTAKING ANY
DEMOLITION WORK. ANY DISCREPANCIES SHOULD BE
BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY.
F. THE CONTRACTOR SHALL SCHEDULE ALL WORK INCLUDING
ANY INTERRUPTION OF UTILITIES 30 DAYS PRIOR TO THE START
OF WORK. THE BUILDING SHALL BE OCCUPIED AND IN USE
DURING THE TIME THE WORK IS BEING PERFORMED.
CONTRACTOR MUST NOTIFY AND SCHEDULE INTERRUPTIONS
WITH THE OWNER OR MAINTAIN ACCESS TO AREAS OUTSIDE
THE SCOPE OF WORK AS REQUIRED BY OWNER.
G. MAINTAIN AND PROTECT ANY AND ALL ITEMS NOTED TO BE
REUSED AND/OR RELOCATED.
H. REFER TO MECHANICAL AND ELECTRICAL DEMOLITION
DRAWINGS FOR ADDITIONAL SCOPE. INCIDENTAL DEMOLITION
DUE TO MECHANICAL AND/OR ELECTRICAL DEMOLITION AND
NEW WORK SHALL BE INCLUDED IN CONTRACT AS WELL AS
REPAIR WORK REQUIRED TO RETURN FINISH SURFACE TO
ORIGINAL CONDITION.
I. CONTRACTOR SHALL REMOVE ALL UNNECESSARY OR
ABANDONED PIPING, CONDUIT AND WIRING THAT IS ACCESSIBLE
WITHOUT ADDITIONAL DEMOLITION.
J. CONTRACTOR SHALL FOLLOW PHASING OF THE WORK AS
INDICATED ON MECHANICAL DOCUMENTS.
K. ALL LIGHT FIXTURES IN AREAS WHERE CEILING IS TO BE
DEMOLISHED ARE TO BE TAKEN DOWN AND STORED. THEY ARE
TO BE REINSTALLED IN ORIGINAL LOCATION WHEN ALL WORK
ABOVE THE CEILING IS COMPLETE.
L. ALL CEILING WORK TO FOLLOW PHASING AND BADGING
REQUIREMENTS AS DESCRIBED IN MECHANICAL AND
ELECTRICAL DRAWINGS.
LEGEND:
EXISTING ACOUSTICAL TILE CEILING AND
GRID TO BE REMOVED
EXISTING GYPSUM BOARD CEILING TO BE
REMOVED
EXISTING SUPPLY AIR DIFFUSER TO BE
REMOVED
EXISTING RETURN AIR GRILLE TO BE
REINSTALLED IF REMOVED DURING
CEILING WORK
EXISTING SUPPLY AIR DIFFUSER TO BE
REINSTALLED IF REMOVED DURING CEILING
WORK
DEMOLITION NOTES:
REMOVE PORTION OF CEILING - SEE GENERAL NOTE
C.
REMOVE AND REINSTALL CEILING MOUNTED
SPEAKERS IN ORIGINAL LOCATION ONCE CEILING
TILES ARE REINSTALLED.
REMOVE TILE AROUND PROJECTOR AND CUT NEW
TILE TO CLEANLY FIT AROUND PROJECTOR MOUNT.
SIMPLEX PLATE ON CEILING TILE TO BE
REINSTALLED ON NEW CEILING TILE IN ORIGINAL
LOCATION .
REMOVE AND REINSTALL CEILING MOUNTED
CAMERA IN ORIGINAL LOCATION ONCE CEILING
TILES ARE REINSTALLED.
THERE IS EQUIPMENT IN THIS ROOM THAT CANNOT
BE RELOCATED. IT IS TO BE PROTECTED DURING
DEMOLITION WORK.
SCALE:1/8" = 1'-0"
C1 SECOND FLOOR CEILING DEMOLITION PLAN
SE
CO
ND
FL
OO
R
CE
ILI
NG
D
EM
OL
ITI
ON
P
LA
N
AR
EA
B
6 57
D112B
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
333C
333B
3XX
333A
335331
322A
322B
318 / 321
2 2 2
MATCH LINE MATCH LINE
N
NO WORK
N
8 4 0 8 16
KEY PLAN
A
B
GENERAL NOTES :
A. THIS DRAWING SHOWS THE GENERAL EXTENT OF SELECTIVE
DEMOLITION. ALL CEILINGS DASHED ARE TO BE REMOVED.
LIGHTS TO BE REMOVED AND REINSTALLED IN NEW CEILING
UNLESS NOTED OTHERWISE. REFER TO OTHER MECHANICAL
DEMOLITION PLANS FOR ADDITIONAL ITEMS TO BE REMOVED OR
RELOCATED.
B. IF THE WORK ABOVE THE CEILING CAN BE PERFORMED BY
SIMPLY REMOVING ACOUSTICAL CEILING TILE, WITHOUT
DAMAGE TO THE GRID, THEN NO CEILING REPLACEMENT IS
REQUIRED. SHOULD ANY REMOVED CEILING TILE BE DAMAGED,
IT MUST BE REPLACED WITH A NEW TILE OF THE EXACT BRAND,
STYLE AND COLOR.
C. IF THE WORK ABOVE THE CEILING REQUIRES THE
REPLACEMENT OF A COMPONENT, SUCH AS A VAV BOX OR A
SMALL AMOUNT OF DUCTWORK, BUT ONLY IMPACTS A SMALL
PORTION OF THE CEILING IN THE SUBJECT ROOM, THE
ARCHITECTURAL DRAWINGS WILL REFLECT A SELECT
DEMOLITION AND REPLACEMENT OF CEILING GRID AND
ACOUSTICAL CEILING TILE, MATCHING THE EXISTING IN EXACT
BRAND, STYLE AND COLOR. THERE ARE OCCASIONS WHERE
THIS LIMITED AMOUNT OF CEILING REPLACEMENT WILL REQUIRE
THAT FLUORESCENT LIGHT FIXTURES, HVAC DIFFUSERS AND
RETURNS, SPRINKLER HEAD ESCUTCHEONS, OR OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED. IN THESE INSTANCES,
THE CEILING IN THAT PARTICULAR ROOM NEED NOT BE
BROUGHT UP TO CURRENT SEISMIC CODES.
D. IF THE MECHANICAL SCOPE OF WORK IN A ROOM REQUIRES
THE REPLACEMENT OF HVAC COMPONENTS, VAV BOXES OR
DUCTWORK THAT IMPACTS A SIGNIFICANT PORTION OF THE
CEILING, A COMPLETE CEILING REPLACEMENT IN THAT SUBJECT
ROOM WILL BE INDICATED. WITH A COMPLETE CEILING
REPLACEMENT, THE CEILING WILL BE BROUGHT UP TO CURRENT
CODE IN REGARDS TO SEISMIC RESTRAINT. THIS WILL REQUIRE
ADDITIONAL SPLAY WIRES, FIXED RESTRAINT OF THE GRID AT
TWO ADJACENT WALLS AND 2 INCH WALL MOLD. COMPLETE
CEILING REPLACEMENT WILL REQUIRE THAT SUSPENDED
FLUORESCENT LIGHTS, HVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS AND ANY OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED WITH THE NEW CEILING
WITH REQUIRED SEISMIC RESTRAINT.
E. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS IN THE FIELD PRIOR TO UNDERTAKING ANY
DEMOLITION WORK. ANY DISCREPANCIES SHOULD BE
BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY.
F. THE CONTRACTOR SHALL SCHEDULE ALL WORK INCLUDING
ANY INTERRUPTION OF UTILITIES 30 DAYS PRIOR TO THE START
OF WORK. THE BUILDING SHALL BE OCCUPIED AND IN USE
DURING THE TIME THE WORK IS BEING PERFORMED.
CONTRACTOR MUST NOTIFY AND SCHEDULE INTERRUPTIONS
WITH THE OWNER OR MAINTAIN ACCESS TO AREAS OUTSIDE
THE SCOPE OF WORK AS REQUIRED BY OWNER.
G. MAINTAIN AND PROTECT ANY AND ALL ITEMS NOTED TO BE
REUSED AND/OR RELOCATED.
H. REFER TO MECHANICAL AND ELECTRICAL DEMOLITION
DRAWINGS FOR ADDITIONAL SCOPE. INCIDENTAL DEMOLITION
DUE TO MECHANICAL AND/OR ELECTRICAL DEMOLITION AND
NEW WORK SHALL BE INCLUDED IN CONTRACT AS WELL AS
REPAIR WORK REQUIRED TO RETURN FINISH SURFACE TO
ORIGINAL CONDITION.
I. CONTRACTOR SHALL REMOVE ALL UNNECESSARY OR
ABANDONED PIPING, CONDUIT AND WIRING THAT IS ACCESSIBLE
WITHOUT ADDITIONAL DEMOLITION.
J. CONTRACTOR SHALL FOLLOW PHASING OF THE WORK AS
INDICATED ON MECHANICAL DOCUMENTS.
K. ALL LIGHT FIXTURES IN AREAS WHERE CEILING IS TO BE
DEMOLISHED ARE TO BE TAKEN DOWN AND STORED. THEY ARE
TO BE REINSTALLED IN ORIGINAL LOCATION WHEN ALL WORK
ABOVE THE CEILING IS COMPLETE.
L. ALL CEILING WORK TO FOLLOW PHASING AND BADGING
REQUIREMENTS AS DESCRIBED IN MECHANICAL AND
ELECTRICAL DRAWINGS.
LEGEND:
EXISTING ACOUSTICAL TILE CEILING AND
GRID TO BE REMOVED
EXISTING GYPSUM BOARD CEILING TO BE
REMOVED
EXISTING SUPPLY AIR DIFFUSER TO BE
REMOVED
EXISTING RETURN AIR GRILLE TO BE
REINSTALLED IF REMOVED DURING
CEILING WORK
EXISTING SUPPLY AIR DIFFUSER TO BE
REINSTALLED IF REMOVED DURING CEILING
WORK
DEMOLITION NOTES:
REMOVE PORTION OF CEILING - SEE GENERAL NOTE
C.
REMOVE AND REINSTALL CEILING MOUNTED
SPEAKERS IN ORIGINAL LOCATION ONCE CEILING
TILES ARE REINSTALLED.
REMOVE TILE AROUND PROJECTOR AND CUT NEW
TILE TO CLEANLY FIT AROUND PROJECTOR MOUNT.
SIMPLEX PLATE ON CEILING TILE TO BE
REINSTALLED ON NEW CEILING TILE IN ORIGINAL
LOCATION .
REMOVE AND REINSTALL CEILING MOUNTED
CAMERA IN ORIGINAL LOCATION ONCE CEILING
TILES ARE REINSTALLED.
THERE IS EQUIPMENT IN THIS ROOM THAT CANNOT
BE RELOCATED. IT IS TO BE PROTECTED DURING
DEMOLITION WORK.
SCALE:1/8" = 1'-0"
C1 THIRD FLOOR CEILING DEMOLITION PLAN
D113A
TH
IR
D
FL
OO
R
CE
ILI
NG
D
EM
OL
ITI
ON
P
LA
N
AR
EA
A
7 57
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
317 / 318 316 339
314A
314B
341A
309A
305 304 /
3XX
3XX 340A
1 1
MATCH LINE MATCH LINE
1 111
N
NO WORK
N
8 4 0 8 16
KEY PLAN
A
B
GENERAL NOTES :
A. THIS DRAWING SHOWS THE GENERAL EXTENT OF SELECTIVE
DEMOLITION. ALL CEILINGS DASHED ARE TO BE REMOVED.
LIGHTS TO BE REMOVED AND REINSTALLED IN NEW CEILING
UNLESS NOTED OTHERWISE. REFER TO OTHER MECHANICAL
DEMOLITION PLANS FOR ADDITIONAL ITEMS TO BE REMOVED OR
RELOCATED.
B. IF THE WORK ABOVE THE CEILING CAN BE PERFORMED BY
SIMPLY REMOVING ACOUSTICAL CEILING TILE, WITHOUT
DAMAGE TO THE GRID, THEN NO CEILING REPLACEMENT IS
REQUIRED. SHOULD ANY REMOVED CEILING TILE BE DAMAGED,
IT MUST BE REPLACED WITH A NEW TILE OF THE EXACT BRAND,
STYLE AND COLOR.
C. IF THE WORK ABOVE THE CEILING REQUIRES THE
REPLACEMENT OF A COMPONENT, SUCH AS A VAV BOX OR A
SMALL AMOUNT OF DUCTWORK, BUT ONLY IMPACTS A SMALL
PORTION OF THE CEILING IN THE SUBJECT ROOM, THE
ARCHITECTURAL DRAWINGS WILL REFLECT A SELECT
DEMOLITION AND REPLACEMENT OF CEILING GRID AND
ACOUSTICAL CEILING TILE, MATCHING THE EXISTING IN EXACT
BRAND, STYLE AND COLOR. THERE ARE OCCASIONS WHERE
THIS LIMITED AMOUNT OF CEILING REPLACEMENT WILL REQUIRE
THAT FLUORESCENT LIGHT FIXTURES, HVAC DIFFUSERS AND
RETURNS, SPRINKLER HEAD ESCUTCHEONS, OR OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED. IN THESE INSTANCES,
THE CEILING IN THAT PARTICULAR ROOM NEED NOT BE
BROUGHT UP TO CURRENT SEISMIC CODES.
D. IF THE MECHANICAL SCOPE OF WORK IN A ROOM REQUIRES
THE REPLACEMENT OF HVAC COMPONENTS, VAV BOXES OR
DUCTWORK THAT IMPACTS A SIGNIFICANT PORTION OF THE
CEILING, A COMPLETE CEILING REPLACEMENT IN THAT SUBJECT
ROOM WILL BE INDICATED. WITH A COMPLETE CEILING
REPLACEMENT, THE CEILING WILL BE BROUGHT UP TO CURRENT
CODE IN REGARDS TO SEISMIC RESTRAINT. THIS WILL REQUIRE
ADDITIONAL SPLAY WIRES, FIXED RESTRAINT OF THE GRID AT
TWO ADJACENT WALLS AND 2 INCH WALL MOLD. COMPLETE
CEILING REPLACEMENT WILL REQUIRE THAT SUSPENDED
FLUORESCENT LIGHTS, HVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS AND ANY OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED WITH THE NEW CEILING
WITH REQUIRED SEISMIC RESTRAINT.
E. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS IN THE FIELD PRIOR TO UNDERTAKING ANY
DEMOLITION WORK. ANY DISCREPANCIES SHOULD BE
BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY.
F. THE CONTRACTOR SHALL SCHEDULE ALL WORK INCLUDING
ANY INTERRUPTION OF UTILITIES 30 DAYS PRIOR TO THE START
OF WORK. THE BUILDING SHALL BE OCCUPIED AND IN USE
DURING THE TIME THE WORK IS BEING PERFORMED.
CONTRACTOR MUST NOTIFY AND SCHEDULE INTERRUPTIONS
WITH THE OWNER OR MAINTAIN ACCESS TO AREAS OUTSIDE
THE SCOPE OF WORK AS REQUIRED BY OWNER.
G. MAINTAIN AND PROTECT ANY AND ALL ITEMS NOTED TO BE
REUSED AND/OR RELOCATED.
H. REFER TO MECHANICAL AND ELECTRICAL DEMOLITION
DRAWINGS FOR ADDITIONAL SCOPE. INCIDENTAL DEMOLITION
DUE TO MECHANICAL AND/OR ELECTRICAL DEMOLITION AND
NEW WORK SHALL BE INCLUDED IN CONTRACT AS WELL AS
REPAIR WORK REQUIRED TO RETURN FINISH SURFACE TO
ORIGINAL CONDITION.
I. CONTRACTOR SHALL REMOVE ALL UNNECESSARY OR
ABANDONED PIPING, CONDUIT AND WIRING THAT IS ACCESSIBLE
WITHOUT ADDITIONAL DEMOLITION.
J. CONTRACTOR SHALL FOLLOW PHASING OF THE WORK AS
INDICATED ON MECHANICAL DOCUMENTS.
K. ALL LIGHT FIXTURES IN AREAS WHERE CEILING IS TO BE
DEMOLISHED ARE TO BE TAKEN DOWN AND STORED. THEY ARE
TO BE REINSTALLED IN ORIGINAL LOCATION WHEN ALL WORK
ABOVE THE CEILING IS COMPLETE.
L. ALL CEILING WORK TO FOLLOW PHASING AND BADGING
REQUIREMENTS AS DESCRIBED IN MECHANICAL AND
ELECTRICAL DRAWINGS.
LEGEND:
EXISTING ACOUSTICAL TILE CEILING AND
GRID TO BE REMOVED
EXISTING GYPSUM BOARD CEILING TO BE
REMOVED
EXISTING SUPPLY AIR DIFFUSER TO BE
REMOVED
EXISTING RETURN AIR GRILLE TO BE
REINSTALLED IF REMOVED DURING
CEILING WORK
EXISTING SUPPLY AIR DIFFUSER TO BE
REINSTALLED IF REMOVED DURING CEILING
WORK
DEMOLITION NOTES:
REMOVE PORTION OF CEILING - SEE GENERAL NOTE
C.
REMOVE AND REINSTALL CEILING MOUNTED
SPEAKERS IN ORIGINAL LOCATION ONCE CEILING
TILES ARE REINSTALLED.
REMOVE TILE AROUND PROJECTOR AND CUT NEW
TILE TO CLEANLY FIT AROUND PROJECTOR MOUNT.
SIMPLEX PLATE ON CEILING TILE TO BE
REINSTALLED ON NEW CEILING TILE IN ORIGINAL
LOCATION .
REMOVE AND REINSTALL CEILING MOUNTED
CAMERA IN ORIGINAL LOCATION ONCE CEILING
TILES ARE REINSTALLED.
THERE IS EQUIPMENT IN THIS ROOM THAT CANNOT
BE RELOCATED. IT IS TO BE PROTECTED DURING
DEMOLITION WORK.
SCALE:1/8" = 1'-0"
C1 THIRD FLOOR CEILING DEMOLITION PLAN
TH
IR
D
FL
OO
R
CE
ILI
NG
D
EM
OL
ITI
ON
P
LA
N
AR
EA
B
8 57
D113B
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
1xx1xx
1XX
1xx 117A
117B
113A
126A
1261XX
114 115
112C112B112A
112D
1xx
MATCH LINE MATCH LINE
GENERAL NOTES:
A. WHERE REPLACING PARTIAL AREAS OF CEILING GRID AND
ACOUSTICAL CEILING TILE, MATCH THE EXISTING IN EXACT
BRAND, STYLE AND COLOR. THERE ARE OCCASIONS WHERE THIS
LIMITED AMOUNT OF CEILING REPLACEMENT WILL REQUIRE THAT
FLUORESCENT LIGHT FIXTURES, HVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS, OR OTHER CEILING MOUNTED
APPLIANCES BE REINSTALLED. IN THESE INSTANCES, THE
CEILING IN THAT PARTICULAR ROOM NEED NOT BE BROUGHT UP
TO CURRENT SEISMIC CODES.
B. IN ROOMS WHICH INDICATE A COMPLETE CEILING
REPLACEMENT THE CEILING WILL BE BROUGHT UP TO CURRENT
CODE IN REGARDS TO SEISMIC RESTRAINT. THIS WILL REQUIRE
ADDITIONAL SPLAY WIRES, FIXED RESTRAINT OF THE GRID AT
TWO ADJACENT WALLS AND 2 INCH WALL MOLD. COMPLETE
CEILING REPLACEMENT WILL REQUIRE THAT SUSPENDED
FLUORESCENT LIGHTS, HAVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS AND ANY OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED WITH THE NEW CEILING
WITH REQUIRED SEISMIC RESTRAINT.
C. IN ANY UNBRACED AREA OF CEILING WHICH IS LESS THAN 1000
SF, IT IS REQUIRED THAT SPRINKLER HEADS AND OTHER
PENETRATIONS BE INSTALLED WITH A 2" OVERSIZED RING,
SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW
FOR ONE INCH OF FREE MOVEMENT IN ALL HORIZONTAL
DIRECTIONS.
D. THE BUILDING IS IN A SEISMIC CATEGORY "D" AND ALL CODE
RELATED CEILING REQUIREMENTS WILL APPLY. SEE CEILING
DETAIL SHEET A115.
E. ALL CEILING MOUNTED SPEAKERS REFERENCED IN
DEMOLITION NOTE 2 TO BE REINSTALLED IN ORIGINAL LOCATION.
F. ALL SIMPLEX PLATES REFERENCED IN DEMOLITION NOTE 4 TO
BE REINSTALLED IN ORIGINAL LOCATION.
G. ALL CEILING MOUNTED CAMERAS REFERENCED IN
DEMOLITION NOTE 5 TO BE REINSTALLED IN ORIGINAL LOCATION
H ALL SPRINKLER HEADS SHALL REMAIN IN CURRENT LOCATION.
INSTALL NEW ESCUTCHEONS PER GENERAL NOTE C.
I. TRIM NEW CEILING TILE TO FIT AROUND ANY EXISTING
CONDUITS AT THE WALLS.
J. ALL LIGHT FIXTURES THAT WERE REMOVED DURING CEILING
DEMOLITION AND HVAC WORK ARE TO BE REINSTALLED IN THEIR
ORIGINAL LOCATIONS.
K. ALL CEILING WORK TO FOLLOW PHASING AND BADGING
REQUIREMENTS AS DESCRIBED IN MECHANICAL AND ELECTRICAL
DRAWINGS.
L. ROOMS 114, 115, AND 117 HAVE EQUIPMENT LOCATED IN THEM
THAT CANNOT BE MOVED. THIS EQUIPMENT IS TO BE PROTECTED
DURING CONSTRUCTION.
LEGEND:
NEW ACOUSTICAL TILE CEILING AND GRID TO
BE INSTALLED.
EXISTING LIGHT FIXTURE TO BE
REINSTALLED UNLESS NOTED OTHERWISE
EXISTING SUPPLY AIR DIFFUSER TO BE
REINSTALLED IF REMOVED DURING CEILING
WORK
EXISTING RETURN AIR GRILLE TO BE
REINSTALLED IF REMOVED DURING
CEILING WORK
NEW SUPPLY AIR DIFFUSER TO BE
INSTALLED
NEW GYPSUM BOARD CEILING TO BE
INSTALLED. PAINT TO MATCH ORIGINAL
CEILING.
N
NO WORK
N
8 4 0 8 16
KEY PLAN
A
B
SCALE:1/8" = 1'-0"
C1 FIRST FLOOR REFLECTED CEILING PLAN
A111A
FIR
ST
FL
OO
R
RE
FL
EC
TE
D
CE
ILI
NG
P
LA
N
AR
EA
A
9 57
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
HG
EDCBA
F
108A
VEND 1 VEND 2
108B SEC MGR
SEC OFCR
107C
107107A108C
104E 104D
104F
104B
106 105
1XX
112F
112E
112D
103A
104A
107B
MATCH LINE MATCH LINE
N
NO WORK
N
8 4 0 8 16
KEY PLAN
A
B
A111 RCP NOTES
GENERAL NOTES:
A. WHERE REPLACING PARTIAL AREAS OF CEILING GRID AND
ACOUSTICAL CEILING TILE, MATCH THE EXISTING IN EXACT
BRAND, STYLE AND COLOR. THERE ARE OCCASIONS WHERE THIS
LIMITED AMOUNT OF CEILING REPLACEMENT WILL REQUIRE THAT
FLUORESCENT LIGHT FIXTURES, HVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS, OR OTHER CEILING MOUNTED
APPLIANCES BE REINSTALLED. IN THESE INSTANCES, THE
CEILING IN THAT PARTICULAR ROOM NEED NOT BE BROUGHT UP
TO CURRENT SEISMIC CODES.
B. IN ROOMS WHICH INDICATE A COMPLETE CEILING
REPLACEMENT THE CEILING WILL BE BROUGHT UP TO CURRENT
CODE IN REGARDS TO SEISMIC RESTRAINT. THIS WILL REQUIRE
ADDITIONAL SPLAY WIRES, FIXED RESTRAINT OF THE GRID AT
TWO ADJACENT WALLS AND 2 INCH WALL MOLD. COMPLETE
CEILING REPLACEMENT WILL REQUIRE THAT SUSPENDED
FLUORESCENT LIGHTS, HAVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS AND ANY OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED WITH THE NEW CEILING
WITH REQUIRED SEISMIC RESTRAINT.
C. IN ANY UNBRACED AREA OF CEILING WHICH IS LESS THAN 1000
SF, IT IS REQUIRED THAT SPRINKLER HEADS AND OTHER
PENETRATIONS BE INSTALLED WITH A 2" OVERSIZED RING,
SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW
FOR ONE INCH OF FREE MOVEMENT IN ALL HORIZONTAL
DIRECTIONS.
D. THE BUILDING IS IN A SEISMIC CATEGORY "D" AND ALL CODE
RELATED CEILING REQUIREMENTS WILL APPLY. SEE CEILING
DETAIL SHEET A115.
E. ALL CEILING MOUNTED SPEAKERS REFERENCED IN
DEMOLITION NOTE 2 TO BE REINSTALLED IN ORIGINAL LOCATION.
F. ALL SIMPLEX PLATES REFERENCED IN DEMOLITION NOTE 4 TO
BE REINSTALLED IN ORIGINAL LOCATION.
G. ALL CEILING MOUNTED CAMERAS REFERENCED IN
DEMOLITION NOTE 5 TO BE REINSTALLED IN ORIGINAL LOCATION
H ALL SPRINKLER HEADS SHALL REMAIN IN CURRENT LOCATION.
INSTALL NEW ESCUTCHEONS PER GENERAL NOTE C.
I. TRIM NEW CEILING TILE TO FIT AROUND ANY EXISTING
CONDUITS AT THE WALLS.
J. ALL LIGHT FIXTURES THAT WERE REMOVED DURING CEILING
DEMOLITION AND HVAC WORK ARE TO BE REINSTALLED IN THEIR
ORIGINAL LOCATIONS.
K. ALL CEILING WORK TO FOLLOW PHASING AND BADGING
REQUIREMENTS AS DESCRIBED IN MECHANICAL AND ELECTRICAL
DRAWINGS.
L. ROOMS 114, 115, AND 117 HAVE EQUIPMENT LOCATED IN THEM
THAT CANNOT BE MOVED. THIS EQUIPMENT IS TO BE PROTECTED
DURING CONSTRUCTION.
LEGEND:
NEW ACOUSTICAL TILE CEILING AND GRID TO
BE INSTALLED.
EXISTING LIGHT FIXTURE TO BE
REINSTALLED UNLESS NOTED OTHERWISE
EXISTING SUPPLY AIR DIFFUSER TO BE
REINSTALLED IF REMOVED DURING CEILING
WORK
EXISTING RETURN AIR GRILLE TO BE
REINSTALLED IF REMOVED DURING
CEILING WORK
NEW SUPPLY AIR DIFFUSER TO BE
INSTALLED
NEW GYPSUM BOARD CEILING TO BE
INSTALLED. PAINT TO MATCH ORIGINAL
CEILING.
SCALE:1/8" = 1'-0"
C1 FIRST FLOOR REFLECTED CEILING PLAN
FIR
ST
FL
OO
R
RE
FL
EC
TE
D
CE
ILI
NG
P
LA
N
AR
EA
B
10 57
A111B
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
212B
212C
212D
212E
212E(1)
212F 212G 212H 212I 212J 213
212K
212L
212M
212N
212O
212P
212Q
201B
201E
201D
STO
201J201I201H201G201F
201E
201L
201M
201N
201O
201T
201Q
201K
214A
201212
MATCH LINE MATCH LINE
N
NO WORK
N
8 4 0 8 16
KEY PLAN
A
B
GENERAL NOTES:
A. WHERE REPLACING PARTIAL AREAS OF CEILING GRID AND
ACOUSTICAL CEILING TILE, MATCH THE EXISTING IN EXACT
BRAND, STYLE AND COLOR. THERE ARE OCCASIONS WHERE THIS
LIMITED AMOUNT OF CEILING REPLACEMENT WILL REQUIRE THAT
FLUORESCENT LIGHT FIXTURES, HVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS, OR OTHER CEILING MOUNTED
APPLIANCES BE REINSTALLED. IN THESE INSTANCES, THE
CEILING IN THAT PARTICULAR ROOM NEED NOT BE BROUGHT UP
TO CURRENT SEISMIC CODES.
B. IN ROOMS WHICH INDICATE A COMPLETE CEILING
REPLACEMENT THE CEILING WILL BE BROUGHT UP TO CURRENT
CODE IN REGARDS TO SEISMIC RESTRAINT. THIS WILL REQUIRE
ADDITIONAL SPLAY WIRES, FIXED RESTRAINT OF THE GRID AT
TWO ADJACENT WALLS AND 2 INCH WALL MOLD. COMPLETE
CEILING REPLACEMENT WILL REQUIRE THAT SUSPENDED
FLUORESCENT LIGHTS, HAVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS AND ANY OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED WITH THE NEW CEILING
WITH REQUIRED SEISMIC RESTRAINT.
C. IN ANY UNBRACED AREA OF CEILING WHICH IS LESS THAN 1000
SF, IT IS REQUIRED THAT SPRINKLER HEADS AND OTHER
PENETRATIONS BE INSTALLED WITH A 2" OVERSIZED RING,
SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW
FOR ONE INCH OF FREE MOVEMENT IN ALL HORIZONTAL
DIRECTIONS.
D. THE BUILDING IS IN A SEISMIC CATEGORY "D" AND ALL CODE
RELATED CEILING REQUIREMENTS WILL APPLY. SEE CEILING
DETAIL SHEET A115.
E. ALL CEILING MOUNTED SPEAKERS REFERENCED IN
DEMOLITION NOTE 2 TO BE REINSTALLED IN ORIGINAL LOCATION.
F. ALL SIMPLEX PLATES REFERENCED IN DEMOLITION NOTE 4 TO
BE REINSTALLED IN ORIGINAL LOCATION.
G. ALL CEILING MOUNTED CAMERAS REFERENCED IN
DEMOLITION NOTE 5 TO BE REINSTALLED IN ORIGINAL LOCATION
H ALL SPRINKLER HEADS SHALL REMAIN IN CURRENT LOCATION.
INSTALL NEW ESCUTCHEONS PER GENERAL NOTE C.
I. TRIM NEW CEILING TILE TO FIT AROUND ANY EXISTING
CONDUITS AT THE WALLS.
J. ALL LIGHT FIXTURES THAT WERE REMOVED DURING CEILING
DEMOLITION AND HVAC WORK ARE TO BE REINSTALLED IN THEIR
ORIGINAL LOCATIONS.
K. ALL CEILING WORK TO FOLLOW PHASING AND BADGING
REQUIREMENTS AS DESCRIBED IN MECHANICAL AND ELECTRICAL
DRAWINGS.
L. ROOMS 114, 115, AND 117 HAVE EQUIPMENT LOCATED IN THEM
THAT CANNOT BE MOVED. THIS EQUIPMENT IS TO BE PROTECTED
DURING CONSTRUCTION.
LEGEND:
NEW ACOUSTICAL TILE CEILING AND GRID TO
BE INSTALLED.
EXISTING LIGHT FIXTURE TO BE
REINSTALLED UNLESS NOTED OTHERWISE
EXISTING SUPPLY AIR DIFFUSER TO BE
REINSTALLED IF REMOVED DURING CEILING
WORK
EXISTING RETURN AIR GRILLE TO BE
REINSTALLED IF REMOVED DURING
CEILING WORK
NEW SUPPLY AIR DIFFUSER TO BE
INSTALLED
NEW GYPSUM BOARD CEILING TO BE
INSTALLED. PAINT TO MATCH ORIGINAL
CEILING.
SCALE:1/8" = 1'-0"
C1 SECOND FLOOR REFLECTED CEILING PLAN
A112A
SE
CO
ND
FL
OO
R
RE
FL
EC
TE
D
CE
ILI
NG
P
LA
N
AR
EA
A
11 57
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
NEW GYPSUM
BOARD, PAINT TO
MATCH EXISTING
CEILING.
212A
212B
212P
212Q
201A
201B
201T
201Q
209B
209C209E
209G
209F
211A
208B
208A
208C
208E
208D
204B
202 202A
203A
203B203C
203D
209A
209D
204A
MATCH LINE MATCH LINE
N
NO WORK
N
8 4 0 8 16
KEY PLAN
A
B
GENERAL NOTES:
A. WHERE REPLACING PARTIAL AREAS OF CEILING GRID AND
ACOUSTICAL CEILING TILE, MATCH THE EXISTING IN EXACT
BRAND, STYLE AND COLOR. THERE ARE OCCASIONS WHERE THIS
LIMITED AMOUNT OF CEILING REPLACEMENT WILL REQUIRE THAT
FLUORESCENT LIGHT FIXTURES, HVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS, OR OTHER CEILING MOUNTED
APPLIANCES BE REINSTALLED. IN THESE INSTANCES, THE
CEILING IN THAT PARTICULAR ROOM NEED NOT BE BROUGHT UP
TO CURRENT SEISMIC CODES.
B. IN ROOMS WHICH INDICATE A COMPLETE CEILING
REPLACEMENT THE CEILING WILL BE BROUGHT UP TO CURRENT
CODE IN REGARDS TO SEISMIC RESTRAINT. THIS WILL REQUIRE
ADDITIONAL SPLAY WIRES, FIXED RESTRAINT OF THE GRID AT
TWO ADJACENT WALLS AND 2 INCH WALL MOLD. COMPLETE
CEILING REPLACEMENT WILL REQUIRE THAT SUSPENDED
FLUORESCENT LIGHTS, HAVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS AND ANY OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED WITH THE NEW CEILING
WITH REQUIRED SEISMIC RESTRAINT.
C. IN ANY UNBRACED AREA OF CEILING WHICH IS LESS THAN 1000
SF, IT IS REQUIRED THAT SPRINKLER HEADS AND OTHER
PENETRATIONS BE INSTALLED WITH A 2" OVERSIZED RING,
SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW
FOR ONE INCH OF FREE MOVEMENT IN ALL HORIZONTAL
DIRECTIONS.
D. THE BUILDING IS IN A SEISMIC CATEGORY "D" AND ALL CODE
RELATED CEILING REQUIREMENTS WILL APPLY. SEE CEILING
DETAIL SHEET A115.
E. ALL CEILING MOUNTED SPEAKERS REFERENCED IN
DEMOLITION NOTE 2 TO BE REINSTALLED IN ORIGINAL LOCATION.
F. ALL SIMPLEX PLATES REFERENCED IN DEMOLITION NOTE 4 TO
BE REINSTALLED IN ORIGINAL LOCATION.
G. ALL CEILING MOUNTED CAMERAS REFERENCED IN
DEMOLITION NOTE 5 TO BE REINSTALLED IN ORIGINAL LOCATION
H ALL SPRINKLER HEADS SHALL REMAIN IN CURRENT LOCATION.
INSTALL NEW ESCUTCHEONS PER GENERAL NOTE C.
I. TRIM NEW CEILING TILE TO FIT AROUND ANY EXISTING
CONDUITS AT THE WALLS.
J. ALL LIGHT FIXTURES THAT WERE REMOVED DURING CEILING
DEMOLITION AND HVAC WORK ARE TO BE REINSTALLED IN THEIR
ORIGINAL LOCATIONS.
K. ALL CEILING WORK TO FOLLOW PHASING AND BADGING
REQUIREMENTS AS DESCRIBED IN MECHANICAL AND ELECTRICAL
DRAWINGS.
L. ROOMS 114, 115, AND 117 HAVE EQUIPMENT LOCATED IN THEM
THAT CANNOT BE MOVED. THIS EQUIPMENT IS TO BE PROTECTED
DURING CONSTRUCTION.
LEGEND:
NEW ACOUSTICAL TILE CEILING AND GRID TO
BE INSTALLED.
EXISTING LIGHT FIXTURE TO BE
REINSTALLED UNLESS NOTED OTHERWISE
EXISTING SUPPLY AIR DIFFUSER TO BE
REINSTALLED IF REMOVED DURING CEILING
WORK
EXISTING RETURN AIR GRILLE TO BE
REINSTALLED IF REMOVED DURING
CEILING WORK
NEW SUPPLY AIR DIFFUSER TO BE
INSTALLED
NEW GYPSUM BOARD CEILING TO BE
INSTALLED. PAINT TO MATCH ORIGINAL
CEILING.
SCALE:1/8" = 1'-0"
C1 SECOND FLOOR REFLECTED CEILING PLAN
SE
CO
ND
FL
OO
R
RE
FL
EC
TE
D
CE
ILI
NG
P
LA
N
AR
EA
B
12 57
A112B
PROJECT NO.
OFSHEET
AI
R
MO
BI
LIT
Y
CO
MM
AN
D
D
AT
E
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
SEAL AREA
D R
AW
IN
G R
E V
IS
IO
N S
D
AT
E
P R
E P
B Y
A P
P R
'D
RECORD DRAWING DATE
ANSI D(34X22)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
ME
NT
O
F T
HE
A
IR
F
OR
CE
R
E V.
D
AT
E D
E S
C R
IP
TI
O N
D R
AW
IN
G R
E V
IS
IO
N S
DKGV 11-2314
BU
ILD
IN
G
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
S U
P V
C H
E N
G R
IR
A D
MA N
COM
MO
I T Y B I L
RE
PA
IR
H
VA
C
SY
ST
EM
, T
RA
IN
IN
G
SU
PP
OR
T B
UI
LD
IN
G
JO
IN
T B
A S
E C
H A
R
LE
S
TO
N
W E
A P
O N
S S
TA
TI
O N
C H
A R
LE
S
TO
N
, S C
ST8
H
G
E W
BA I R A
I N62
SG
JR
CM
.06
.20
ST
UB
BS
M
UL
DR
OW
H
ER
IN
a rc hit ec ts
Hi bb en
S tre et , M t.
Pl ea sa nt , S
C
333C
333B
3XX
333A
335331
322A
322B
318 / 321
333C
333B
3XX
333A
335331
322A
322B
318 / 321
333C
333B
3XX
333A
322A
322B
318 / 321
MATCH LINE MATCH LINE
N
NO WORK
N
8 4 0 8 16
KEY PLAN
A
B
GENERAL NOTES:
A. WHERE REPLACING PARTIAL AREAS OF CEILING GRID AND
ACOUSTICAL CEILING TILE, MATCH THE EXISTING IN EXACT
BRAND, STYLE AND COLOR. THERE ARE OCCASIONS WHERE THIS
LIMITED AMOUNT OF CEILING REPLACEMENT WILL REQUIRE THAT
FLUORESCENT LIGHT FIXTURES, HVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS, OR OTHER CEILING MOUNTED
APPLIANCES BE REINSTALLED. IN THESE INSTANCES, THE
CEILING IN THAT PARTICULAR ROOM NEED NOT BE BROUGHT UP
TO CURRENT SEISMIC CODES.
B. IN ROOMS WHICH INDICATE A COMPLETE CEILING
REPLACEMENT THE CEILING WILL BE BROUGHT UP TO CURRENT
CODE IN REGARDS TO SEISMIC RESTRAINT. THIS WILL REQUIRE
ADDITIONAL SPLAY WIRES, FIXED RESTRAINT OF THE GRID AT
TWO ADJACENT WALLS AND 2 INCH WALL MOLD. COMPLETE
CEILING REPLACEMENT WILL REQUIRE THAT SUSPENDED
FLUORESCENT LIGHTS, HAVAC DIFFUSERS AND RETURNS,
SPRINKLER HEAD ESCUTCHEONS AND ANY OTHER CEILING
MOUNTED APPLIANCES BE REINSTALLED WITH THE NEW CEILING
WITH REQUIRED SEISMIC RESTRAINT.
C. IN ANY UNBRACED AREA OF CEILING WHICH IS LESS THAN 1000
SF, IT IS REQUIRED THAT SPRINKLER HEADS AND OTHER
PENETRATIONS BE INSTALLED WITH A 2" OVERSIZED RING,
SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW
FOR ONE INCH OF FREE MOVEMENT IN ALL HORIZONTAL
DIRECTIONS.
D. THE BUILDING IS IN A SEISMIC CATEGORY "D" AND ALL CODE
RELATED CEILING REQUIREMENTS WILL APPLY. SEE CEILING
DETAIL SHEET A115.
E. ALL CEILING MOUNTED SPEAKERS REFERENCED IN
DEMOLITION NOTE 2 TO BE REINSTALLED IN ORIGINAL LOCATION.
F. ALL SIMPLEX PLATES REFERENCED IN DEMOLITION NOTE 4 TO
BE REINSTALLED IN ORIGINAL LOCATION.
G. ALL CEILING MOUNTED CAMERAS REFERENCED IN
DEMOLITION NOTE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .