SECTION_10_10_00_DISPLAY_CASES.pdf

PDF 148 KB Posted

Attached to
Renovate Student Dorms Winters Manor Federal contract opportunity
Solicitation number
FA3010-14-R-0006
Issued by
Department of the Air Force Air Education and Training Command

About this file

Add 3 Specification

View the file

Other files for this federal contract opportunity

Other files attached to Renovate Student Dorms Winters Manor, newest first.
File Type Posted
Section_12_48_23_Entrance_Floor_Grids.pdf PDF
RFI's_Winters_Manor.pdf PDF
MAHG10-1032_PAE_addendum_3.pdf PDF
FA3010-14-R-0006-0007.pdf PDF
Amendment_0006.pdf PDF
MAHG101032_Addendum_2.pdf PDF
Amendment_0005.pdf PDF
Add_2_SECTION_12_36_00_COUNTERTOPS.pdf PDF
Amendment_0004.pdf PDF
Winters_Manor_Additional_QA.pdf PDF
MAHG101032_Addendum_1_RFIs.pdf PDF
Add_1_SECTION_16_50_00_LIGHTING.pdf PDF
Add_1_SECTION_16_11_00_RACEWAYS.pdf PDF
Add_1_SECTION_15_40_00_PLUMBING.pdf PDF
Add_1_SECTION_08_11_13_STEEL_DOORS_AND_FRAMES.pdf PDF
Add_1_SECTION_16_72_60_PUBLIC_ADDRESS_AND_MASS_NOTIFICATION_SYSTEMS.pdf PDF
Add_1_SECTION_15_20_00_DOMESTIC_WATER_PIPING.pdf PDF
Add_1_Section_07_56_00_Fluid_Applied_Roofing.pdf PDF
Add_1_SECTION_16_00_00_GENERAL_PROVISIONS-ELECTRICAL.pdf PDF
Add_1_MAHG10-1032_Drawing_Sheets_Revision_01_5_21_14.pdf PDF
Amendment_0003.pdf PDF
Add_1_SECTION_09_68_13_TILE_CARPETING.pdf PDF
Amendment_0002.pdf PDF
Amendment_0001.pdf PDF
Site_Visit_Sign_In.pdf PDF
Solicitation.pdf PDF
Attachment_5_Past_Performance_Reference_List.pdf PDF
Attachment_6_SF_1444.pdf PDF
Attachment_6_Instructions.pdf PDF
WD_MS140119.pdf PDF
MAHG101032_Repair_student_Dorm_7404_SPECIFICATIONS.pdf PDF
MAHG101032_DRAWINGS_2013-2-20.pdf PDF
Attachment_4_Performance_Questionnaire.pdf PDF
Show all 33

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MAHG10-1032

Section 10 10 00_1-2

SECTION 10100 - VISUAL DISPLAY BOARDS

PART 1 GENERAL

1.1 SECTION INCLUDES

A. Bulletin boards – Enclosed

1.2 SUBMITTALS

A. Product Data: Provide manufacturer's descriptive literature including item number, size, description and representative picture.

B. Shop Drawings: Provide shop drawings where manufacturer data from 1.2.A above is insufficient for verification of suitability to application and installation.

C. Samples: Provide samples of board surface and framing where manufacturer data from 1.2.A above is insufficient for verification of suitability to application and installation.

1.3 DELIVERY, STORAGE & HANDLING

A. Packing, Shipping, Handling and Unloading: Panels are to be packed in wooden crates for shipment to site. Cardboard only packing is not acceptable.

B. Acceptance at Site: Crated panels are to be opened and inspected for shipment damage and losses including scratches and dents on the panel and framing surfaces, frame misalignment due to rough handling and missing components and accessories. Any such shipping damage shall be noted on the bill of lading with the concurrence of a representative of the delivering carrier. Signing the bill of lading without interior crate inspection is not acceptable.

C. Storage and Protection: Panels and included accessories shall be returned to the shipping crate or other suitable container for storage in a protected, office environment type area prior to installation. Excessive heat, cold or humidity are not acceptable.

1.4 PROJECT/SITE CONDITIONS

A. Project/Site Environmental Requirements: Panels shall not be installed until site conditions are such that panels will not be damaged or contaminated by remaining construction activities. If necessary, provide physical protection to protect an installed panel's surfaces from physical damage. Accessories are to be separately retained for delivery to the owner.

1.5 WARRANTY

A. Warranty shall be the manufacturer's stated warranty plus any extended warranty provided by the manufacturer of any raw construction materials. Warranty shall apply to replacement/repair of returned materials only and shall not include costs of removal/reinstallation and shipping unless specifically allowed.

MAHG10-1032

Section 10 10 00_2-2

PART 2 PRODUCTS

2.1 MATERIALS

A. Bulletin boards - plain and enclosed:

1. Panel to be constructed of 7/32" minimum thickness natural cork laminated to ¼" nominal hardboard backing.

2. Enclosure to be constructed of mitered aluminum framing with a 2-3" depth with hinged door.

a. Hinged door enclosures shall include keyed locking doors, continuous hinges, and acrylic plastic windows.

3. Include concealed mounting brackets.

PART 3 EXECUTION

3.1 INSTALLATION

A. Install per manufacturers supplied installation instructions.

3.2 CLEANING

A. Clean panel surface per manufacturer's supplied instructions. Use of cleaning solutions other than specified acrylic and aluminum cleaner or abrasive cleaners of any kind is prohibited.

END OF SECTION