| Roof Summary | 7-Feb-17 |
| ROOFING BID SCHEDULE | |
| IDIQ 2017-2022 | |
| Project No. FTFA 16-7000 Spec. No. 16AD | |
| 2017 THROUGH 2022 |
Contracting = 0.00
&P of &N &F - &A
BASE YEAR
| 7-Feb-17 | |
| ROOFING BID SCHEDULE | |
| IDIQ 2017-2022 | |
| Project No. FTFA 16-7000 Spec. No. 16AD | |
| 0.00 |
| BASIC YEAR | Contractor | |||||||
| LINE ITEM | SPEC | DESCRIPTION | Unit | EST. QTY. | UNIT PRICE | EST. TOTAL PRICE | UNIT PRICE | EST. TOTAL PRICE |
| 02 41 00 | DIVISION2-SELECTIVE DEMOLITION | |||||||
| 0001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK | LF | 1000 | $0.00 | ||||
| 0002 | REMOVE AND REPLACE WOOD DECKING | SF | 500 | $0.00 | ||||
| 0003 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING | SF | 2000 | $0.00 | ||||
| 0004 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 2" THICK | LF | 1000 | $0.00 | ||||
| 0005 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | SF | 500 | $0.00 | ||||
| 02 41 00 | DIVISION 2-TEAR-OFFS | |||||||
| 0006 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES NOT INCLUDE INSULATION) | SQ | 2000 | $0.00 | ||||
| 0007 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 2" THICK | SQ | 2000 | $0.00 | ||||
| 0008 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION OVER 2" THICK | BF | 1000 | $0.00 | ||||
| 0009 | REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | $0.00 | ||||
| 0010 | REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | $0.00 | ||||
| 0011 | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 200 | $0.00 | ||||
| 0012 | DEMOLITION, HAULING, AND DISPOSAL OF AGGREGATE BALLAST. INCLUDE SPUDDING BACK AND VACUUMING LOOSE AGGREGATE FROM ENTIRE ROOF SURFACE. | SQ | 200 | $0.00 | ||||
| 0013 | REMOVE SINGLE PLY ROOFING (INCLUDING PVC, EPDM, PIB, TPO AND OTHER MEMBRANE ROOFING) DOWN TO THE DECK. INCLUDE MEMBRANE, PENETRATION & WALL FLASHINGS AND MEMBRANE FASTENERS. NOT TO INCLUDE INSULATION, CRICKETS AND INSULATION FASTENERS. | SQ | 200 | $0.00 | ||||
| DIVISION 2-ASBESTOS ABATEMENT/ LEAD CONTROLS | ||||||||
| 0014 | 02 82 14 | CLASS I AND/OR CLASS II ASBESTOS CONTAINING ROOF MATERIALS (ACRM) ROOF MEMBRANE. | SF | 500 | $0.00 | |||
| 0015 | 02 82 16 | CEMENTITIOUS ASBESTOS FIBER ROOF DECK/FORM BOARD | SF | 100 | $0.00 | |||
| 0016 | 02 83 13 | LEAD CONTROLS | SF | 100 | $0.00 | |||
| 04 01 20 | DIVISION 4-MASONRY | |||||||
| 0016 | WATER BLAST CLEAN EXISTING MASONRY SURFACE IN ACCOURDANCE WITH PAINT MANUFACTURER'S RECOMMENDATIONS. | SF | 500 | $0.00 | ||||
| 0017 | CONCRETE MASONRY UNITS TO INCLUDE GROUTING, TUCK POINTING, FORMWORK, AND SUPPORTS. PERFORM WORK IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. | SF | 200 | $0.00 | ||||
| 05 30 00 | DIVISION 5-STEEL ROOF DECK | |||||||
| 0018 | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 100 | $0.00 | ||||
| DIVISION 5-METALS | ||||||||
| 05 40 00 | COLD-FORMED METAL FRAMING | |||||||
| 0019 | COLD-FORMED METAL FRAMING MEMBERS OR SOFFIT FRAMING, TO INCLUDE SADDLES, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND NAILERS ATTACHED AT THE TOPS OF CONCRETE OR MASONRY CURBS, EXPANSION JOINTS AND ROOF EDGES. FRAMING MEMBERS ARE 4" TO 8" WIDE BY 18 GAUGE OR THINNER. | LF | 1000 | $0.00 | ||||
| 0020 | RETROFIT SUB-PURLIN AND/OR FORMED SHAPED FRAMING SYSTEM MECHANICALLY FASTENED TO EXISTING AND/OR SUBSTRATE IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS. MINIMUM 16 GAUGE THICKNESS | LF | 1000 | $0.00 | ||||
| 05 50 13 | METAL FABRICATION | |||||||
| 0021 | SHOP PRIMED STEEL MATERIALS INCLUDING BUT NOT LIMITED TO: PLATES, ANGLES, ANCHOR BOLTS, STEEL PIPE SLEEVES, WEDGE TYPE INSERTS, EXPANSION ANCHORS, FRAMING, SUPPORTS AND FABRICATED ITEMS FOR APPLICATIONS THAT ARE NOT SPECIFIED IN OTHER SPECIFICATION SECTIONS. | LB | 500 | $0.00 | ||||
| 05 51 00, 05 51 33 | STAIRS AND LADDERS | |||||||
| FABRICATE AND INSTALL ALUMINUM ROOF ACCESS STAIRS OR LADDERS | LB | 100 | $0.00 | |||||
| FABRICATE AND INSTALL GALVANIZED STEEL ROOF ACCESS STAIRS OR LADDERS | LB | 100 | $0.00 | |||||
| REMOVE AND DISPOSE OF EXISTING ACCESS STAIRS OR LADDERS | LB | 100 | $0.00 | |||||
| 05 52 00 | PIPE AND TUBE RAILINGS | |||||||
| 0022 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT ALUMINUM PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 200 | $0.00 | ||||
| 0023 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT GALVANIZED STEEL PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 200 | $0.00 | ||||
| 0024 | REMOVE AND DISPOSE OF PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 200 | $0.00 | ||||
| 06 10 00 | DIVISION 6-ROUGH CARPENTRY | |||||||
| 0025 | FURNISH AND INSTALL PRESERVATIVE TREATED WOOD ROOF NAILERS, WHICH INCLUDES WOOD SADDLES OR CRICKETS, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND WOOD NAILERS BOLTED TO TOPS OF CONCRETE OR MASONRY CURBS AND AT EXPANSION JOINTS | BF | 500 | $0.00 | ||||
| 0026 | REMOVE AND REPLACE 3/8", 5/8"OR 3/4" ROOF SHEATHING OR SOFFIT ON RESIDENTIAL UNITS | SF | 200 | $0.00 | ||||
| 0027 | REMOVE AND REPLACE ROOF DECKING FOR RESIDENTIAL UNITS, WHICH INCLUDES 1x OR 2x DECKING | SF | 200 | $0.00 | ||||
| 0028 | FURNISH AND INSTALL ROOFING LUMBER FOR RESIDENTIAL UNITS, WHICH INCLUDES RAFTERS, STUDS, PLATES, CAPS, COLLAR BEAMS, SLEEPERS, NAILING STRIPS, SILLS, HEADERS AND FASCIA | BF | 200 | $0.00 | ||||
| 07 22 00 | DIVISION 7-INSULATION | |||||||
| POLYISOCYANURATE BOARD INSULATION | ||||||||
| 0029 | 1" THICK, R5.7 | SQ | 200 | $0.00 | ||||
| 0030 | 1.5" THICK R8.6 | SQ | 100 | $0.00 | ||||
| 0031 | 2" THICK, R11.4 | SQ | 200 | $0.00 | ||||
| 0032 | 3" THICK, R17.1 | SQ | 200 | $0.00 | ||||
| 0033 | 4" THICK, R22.8 | SQ | 100 | $0.00 | ||||
| 0034 | 5" THICK, R28.5 | SQ | 1,000 | $0.00 | ||||
| 0035 | 5.5" THICK, R31.3 | SQ | 200 | $0.00 | ||||
| 0036 | TAPERED FILL INSULATION BOARD FOR DRAINAGE | BF | 75,000 | $0.00 | ||||
| 07 22 00 | PROTECTION BOARDS: | |||||||
| 0037 | GLASS MAT GYPSUM ROOF BOARD | SQ | 500 | $0.00 | ||||
| 0038 | HIGH DENSITY WOOD FIBER BOARD | SQ | 500 | $0.00 | ||||
| 0039 | FIBER CANTS | LF | 1,000 | $0.00 | ||||
| 0040 | WOOD CANTS | LF | 1,000 | $0.00 | ||||
| 0041 | SHEATING PAPER FOR WOOD DECKS | SQ | 50 | $0.00 | ||||
| 0042 | 07 21 16 | BATT ROOF INSULATION, R-19 | SF | 1,000 | $0.00 | |||
| 0040 | BATT ROOF INSULATION, R-30 | SF | 1,000 | $0.00 | ||||
| 0043 | 07 61 14 | METAL ROOF INSULATION, R30 | SQ | 200 | $0.00 | |||
| 07 31 13 | DIVISION 7-SHINGLE ROOFING SYSTEMS | |||||||
| 0041 | FURNISH AND INSTALL NEW 3-TAB MINERAL SURFACED ASPHALT STRIP SHINGLE SYSTEM | SQ | 300 | $0.00 | ||||
| 0042 | FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL ASHPALT SHINGLE SYSTEM | SQ | 100 | $0.00 | ||||
| 0043 | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW ASPHALT STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS | SQ | 10 | $0.00 | ||||
| 0044 | ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER) | SQ | 50 | $0.00 | ||||
| multiple | DIVISION 7-UNDERLAYMENT | |||||||
| 0045 | FELT, ASPHALT SATURATED, 30 POUND | SQ | 500 | $0.00 | ||||
| 0046 | SELF ADHERING LEAK BARRIER (PEAL AND STICK) | SQ | 500 | $0.00 | ||||
| 07 52 00 | DIVISION 7-BITUMINOUS ROOFING (BURS) | |||||||
| 0047 | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 1000 | $0.00 | ||||
| 0048 | REMOVE AND REPLACE PITCH PAN | EA | 30 | $0.00 | ||||
| FOR RESIDENTIAL UNITS | ||||||||
| 0048 | SINGLE-PLY SBS MODIFIED CAP SHEET FOR RESIDENTIAL UNITS | SQ | 250 | $0.00 | ||||
| 07 01 50 | DIVISION 7-PARTIAL BURS REPAIRS | |||||||
| 0049 | REPAIRS BLISTERS | SF | 500 | $0.00 | ||||
| 0050 | REPAIR SPLITS | LF | 200 | $0.00 | ||||
| 0051 | REPAIR RIDGES | LF | 200 | $0.00 | ||||
| 0052 | APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREAS | SF | 500 | $0.00 | ||||
| 07 31 13 | DIVISION 7-PREPARED ROLL ROOFING | |||||||
| 0053 | FURNISH AND INSTALL NEW MINERAL SURFACED ASPHALT PREPARED ROLL ROOFING | SQ | 50 | $0.00 | ||||
| 0054 | CUT-OUT AND PATCH ROLL ROOFING | SQ | 5 | $0.00 | ||||
| 07 54 19 | DIVISION 7-POLYVINYL-CHLORIDE ROOFING | |||||||
| 0055 | FURNISH/INSTALL FULLY ADHERED PVC SYSTEM- 72 MILS | SQ | 1000 | $0.00 | ||||
| 0056 | FURNISH/INSTALL MECHANICALLY FASTENED PVC SYSTEM- 72 MIL | SQ | 1000 | $0.00 | ||||
| 0057 | PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 500 | $0.00 | ||||
| 0058 | PVC LAMINATED METAL FLASHING 18.1" TO 36" STRETCH OUT | LF | 500 | $0.00 | ||||
| 0059 | PVC VENT BOOTS | EA | 50 | $0.00 | ||||
| 0060 | PVC UNIVERSAL CORNERS | EA | 200 | $0.00 | ||||
| 0061 | PATCH AND REPAIR PVC SYSTEM | SF | 90 | $0.00 | ||||
| 07 14 00 | DIVISION 7-FLUID APPLIED WATERPROOFING | |||||||
| 0062 | FLUID APPLIED COATING SYSTEM FOR METAL ROOFS | SQ | 100 | $0.00 | ||||
| 0063 | ENERGY STAR RATED COATING SYSTEM APPLIED TO NEW BUR ROOFING WITH MODIFIED CAP SHEET | SQ | 50 | $0.00 | ||||
| 0064 | ELASTOMERIC COATING FOR ROOF REPAIRS | SQ | 10 | $0.00 | ||||
| multiple | DIVISION 7-TRAFFIC-BEARING ROOF DECK SURFACING | |||||||
| 0065 | TRAFFIC-BEARING ROOF SURFACING SYSTEM | SQ | 10 | $0.00 | ||||
| 07 60 00 | DIVISION 7-SHEET METAL WORK, GENERAL | |||||||
| FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION) | ||||||||
| 0066 | GALVANIZED METAL, 4"- 5" | LF | 500 | $0.00 | ||||
| 0067 | GALVANIZED METAL, 6" - 7" | LF | 100 | $0.00 | ||||
| 0068 | ALUMINUM, 4" - 5" | LF | 500 | $0.00 | ||||
| 0069 | ALUMINUM, 6" - 7" | LF | 100 | $0.00 | ||||
| 0070 | 2-PIECE GALVANIZED METAL, 7" - 10" | LF | 50 | $0.00 | ||||
| 0071 | 2-PIECE GALVANIZED METAL, 10" - 12" | LF | 50 | $0.00 | ||||
| 0072 | 2-PIECE ALUMINUM, 7" - 10" | LF | 50 | $0.00 | ||||
| 0073 | 2-PIECE ALUMINUM, 10" - 12" | LF | 50 | $0.00 | ||||
| FURNISH AND INSTALL: | ||||||||
| 0074 | GALVANIZED METAL DRIP EDGE | LF | 500 | $0.00 | ||||
| 0075 | GALVANIZED METAL COUNTERFLASHING | SF | 400 | $0.00 | ||||
| 0076 | GALVANIZED METAL VALLEY FLASHING | SF | 400 | $0.00 | ||||
| 0077 | GALVANIZED METAL STEP FLASHING | SF | 200 | $0.00 | ||||
| 0078 | GALVANIZED METAL BASE FLASHING | SF | 200 | $0.00 | ||||
| 0079 | GALVANIZED METAL FLASHING- FLAT SHEET | SF | 200 | $0.00 | ||||
| 0080 | GALVANIZED METAL CAP FLASHING | SF | 200 | $0.00 | ||||
| 0081 | ALUMINUM DRIP EDGE | LF | 500 | $0.00 | ||||
| 0082 | ALUMINUM COUNTERFLASHING | SF | 200 | $0.00 | ||||
| 0083 | ALUMINUM VALLEY FLASHING | SF | 200 | $0.00 | ||||
| 0084 | ALUMINUM STEP FLASHING | SF | 200 | $0.00 | ||||
| 0085 | ALUMINUM BASE FLASHING | SF | 200 | $0.00 | ||||
| 0086 | ALUMINUM FLASHING - FLAT SHEET | SF | 200 | $0.00 | ||||
| 0087 | ALUMINUM CAP FLASHING | SF | 200 | $0.00 | ||||
| 0088 | METAL RIDGE VENT | LF | 200 | $0.00 | ||||
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT: | ||||||||
| 0089 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 100 | $0.00 | ||||
| 0090 | ALUMINUM CAPPED CURB | LF | 100 | $0.00 | ||||
| 0091 | GALVANIZED CAPPED CURB | LF | 100 | $0.00 | ||||
| 0092 | REMOVE AND REPLACE VENTILATOR, ROOFTOP | EA | 5 | $0.00 | ||||
| 0093 | REMOVE AND REPLACE VENTILATOR, RIDGE | LF | 40 | $0.00 | ||||
| 0094 | REMOVE AND REPLACE VENTILATOR, GABLE | EA | 2 | $0.00 | ||||
| 0095 | REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHED | EA | 2 | $0.00 | ||||
| 0096 | REMOVE AND REPLACE ROOF SCUTTLE | EA | 2 | $0.00 | ||||
| 07 42 13 | DIVISION 7-METAL WALL PANELS | |||||||
| 0097 | FURNISH AND INSTALL WALL PANELS | SF | 250 | $0.00 | ||||
| 0098 | FURNISH AND INSTALL FABRICATED WALL PANEL ASSEMBLY (INCLUDING INSULATION) | SF | 100 | $0.00 | ||||
| DIVISION 7-GUTTERS AND DOWNSPOUTS | ||||||||
| 0099 | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 750 | $0.00 | ||||
| FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC. | ||||||||
| 0100 | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 200 | $0.00 | ||||
| 0101 | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 1000 | $0.00 | ||||
| 0102 | ALUMINUM, 4" X 5" | LF | 1000 | $0.00 | ||||
| 0103 | ALUMINUM, 5" X 7" | LF | 100 | $0.00 | ||||
| FURNISH & INSTALL NEW DOWNSPOUTS, INCLUDES BRACKETS, ETC. | ||||||||
| 0104 | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 500 | $0.00 | ||||
| 0105 | ALUMINUM, 3" X 4" | LF | 100 | $0.00 | ||||
| 0106 | FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 20 | $0.00 | ||||
| 0107 | INSTALL NEW THROUGH WALL SCUPPERS | EA | 10 | $0.00 | ||||
| 05 40 00 | DIVISION 7-MANUFACTURED ROOF FRAMING SYSTEM | |||||||
| 0108 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE <= 100 SQ | SQ | 150 | $0.00 | ||||
| 0109 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE =>100 SQ | SQ | 150 | $0.00 | ||||
| DIVISION 7-STANDING SEAM METAL ROOF SYSTEM | ||||||||
| 0110 | 07 41 13 | NEW METAL ROOF PANELS, ARCHITECTURAL/NON-STRUCTURAL PER SPEC UFGS 07 41 13 | SQ | 400 | $0.00 | |||
| 0169 | 07 61 14 | NEW STEEL STANDING SEAM METAL ROOFING, STRUCTURAL, PER SPEC. UFGS 07 61 14 | SQ | 400 | $0.00 | |||
| 0170 | 07 61 15 | NEW ALUMINUM STANDING SEAM METAL ROOF, STRUCTURAL, PER SPEC. UFGS 07 61 15 | SQ | 100 | $0.00 | |||
| 0171 | FASCIA PANEL SYSTEM | SF | 750 | $0.00 | ||||
| 0172 | NON-PERFORATED SOFFIT PANEL | SF | 500 | $0.00 | ||||
| 0173 | PERFORATED SOFFIT PANEL | SF | 500 | $0.00 | ||||
| 0174 | FELT OVER WOOD DECKS | SQ | 100 | $0.00 | ||||
| 07 92 00 | DIVISION 7-CAULKING AND SEALANTS | |||||||
| 0175 | REMOVE EXISTING CAULKING, CLEAN JOINT | LF | 1000 | $0.00 | ||||
| 0176 | SILICONE CAULKING/SEALANT | LF | 500 | $0.00 | ||||
| 0177 | CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1, OR APPROVED EQUAL) | LF | 500 | $0.00 | ||||
| 09 90 00 | DIVISION 9-PAINTING | |||||||
| 0178 | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | 1,000 | $0.00 | ||||
| 0179 | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 1,000 | $0.00 | ||||
| 22 00 00 | DIVISION 15-ROOF DRAINS | |||||||
| 0180 | REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 5 | $0.00 | ||||
| 0181 | REMOVE AND REPLACE EXISTING ROOF DRAIN, INCLUDES NEW CAST IRON DOME STRAINER | EA | 20 | $0.00 | ||||
| 26 41 00 | DIVISION 16-LIGHTING PROTECTION | |||||||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERS | ||||||||
| 0182 | REMOVE AND REINSTALL EXISTING CONDUCTOR | LF | 200 | $0.00 | ||||
| 0183 | REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPS | EA | 25 | $0.00 | ||||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTNING PROTECTION SYSTEM | ||||||||
| 0184 | AIR TERMINALS, INCLUDES COPPER BASE FOR NON-METAL ROOFS | EA | 20 | $0.00 | ||||
| 0185 | AIR TERMINALS, INCLUDES ALUMINUM BASE FOR METAL ROOFS | EA | 20 | $0.00 | ||||
| 0186 | CONDUCTORS | LF | 300 | $0.00 | ||||
| 0187 | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 100 | $0.00 | ||||
| 0188 | CONNECTORS | EA | 20 | $0.00 | ||||
| 0189 | COUNTERPOISE CONDUCTOR | LF | 1000 | $0.00 | ||||
| 0190 | GROUNDING RODS, 3/4" DIAMETER x 60' LONG | EA | 10 | $0.00 | ||||
| 0191 | SURGE PROTECTION | EA | 1 | $0.00 | ||||
| 0192 | FURNISH AND INSTALL GROUND ACCESS PVC TEST WELL, 12" I.D. X 24" LONG WITH 1/4" GALVANIZED FRICTION FIT COVER WITH THE WORD "GROUND" ENGREAVED ON TOP OF THE COVER | EA | 10 | $0.00 | ||||
| 0193 | UL SITE INSPECTION | EA | 10 | $0.00 | ||||
| MISCELLANEOUS ROOFING ITEMS | ||||||||
| 0194 | FURNISH AND INSTALL PERMANENT FALL PROTECTION ANCHORAGE (PER EACH ANCHOR POINT) | EA | 50 | $0.00 | ||||
| 0195 | EXTEND PLUMBING VENTS | LF | 40 | $0.00 | ||||
| 0196 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 30 | $0.00 | ||||
| 0197 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR) | EA | 40 | $0.00 | ||||
| 0198 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH COLLAR TYPE FLASHING | EA | 40 | $0.00 | ||||
| 0199 | REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 200 | $0.00 | ||||
| 0200 | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKS | SQ | 200 | $0.00 | ||||
| 0201 | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP) | EA | 10 | $0.00 | ||||
| 0202 | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 100 | $0.00 | ||||
| 0203 | ROLL COIL RIDGE VENT | LF | 100 | $0.00 | ||||
| 0204 | SPUD EXISTING ROOF TO INSULATION | SQ | 200 | $0.00 | ||||
| 0205 | CUT AND PATCH CONCRETE | LF | 1000 | $0.00 | ||||
| 0206 | TRENCH AND BACKFILL | LF | 1000 | $0.00 | ||||
| 0207 | CONCRETE SPLASH BLOCKS | EA | 50 | $0.00 | ||||
| 0208 | TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREA | EA | 10 | $0.00 | ||||
| 0209 | MOISTURE INSPECTION BY THERMAL IMAGING SURVEY | SF | 1000 | $0.00 | ||||
| 0210 | AS-BUILT DRAWINGS PER SPEC. NO. 01 11 00 | JOB | 10 | $0.00 | ||||
| 0211 | ENGINEERING RATE STRUCTURAL | HR | 20 | $0.00 | ||||
| 0212 | ENGINEERING RATE STRUCTURAL - FALL PROTECTION | JOB | 40 | $0.00 | ||||
| 0213 | MECHANICAL SUBCONTRACTOR | HR | 20 | $0.00 | ||||
| 0214 | ELECTRICAL SUBCONTRACTOR | HR | 20 | $0.00 | ||||
| 0215 | LABOR RATE - MISCELLANEOUS WORK | MH | 100 | $0.00 | ||||
| SPECIAL CONDITIONS AND CIRCUMSTANCES | ||||||||
| 0216 | HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOB | CSQ | 5 | $0.00 | ||||
| Subtotal | $0.00 | |||||||
| MODIFIERS | ||||||||
| 0217 | MULTIPLIER % TO BE ADDED TO TOTAL FOR GENERAL PROJECT REQUIREMENTS, i.e. MOBILIZATION/DEMOBILIZATION, EQUIPMENT RENTAL, ONSITE BATHROOM, SAFETY PROCEDURES, ETC. | % | $0.00 | |||||
| Subtotal | $0.00 | |||||||
| 0218 | MULTIPLIER % TO BE ADDED TO TOTAL FOR URGENT DELIVERY ORDER (UDO)-TEMPORARY DRY-IN WORK ONLY | % | $0.00 | |||||
| OPTION BASE YEAR TOTAL | $0.00 |
&"Arial,Bold"&10Page &P of &N &"Arial,Bold"&10&A - &F
YEAR ONE
| 7-Feb-17 | |
| ROOFING BID SCHEDULE | |
| IDIQ 2017-2022 | |
| Project No. FTFA 16-7000 Spec. No. 16AD | |
| 0.00 |
| BASIC YEAR | Contractor | |||||||
| LINE ITEM | SPEC | DESCRIPTION | Unit | EST. QTY. | UNIT PRICE | EST. TOTAL PRICE | UNIT PRICE | EST. TOTAL PRICE |
| 02 41 00 | DIVISION2-SELECTIVE DEMOLITION | |||||||
| 1001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK | LF | 1000 | $0.00 | ||||
| 1002 | REMOVE AND REPLACE WOOD DECKING | SF | 500 | $0.00 | ||||
| 1003 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING | SF | 2000 | $0.00 | ||||
| 1004 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 2" THICK | LF | 1000 | $0.00 | ||||
| 1005 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | SF | 500 | $0.00 | ||||
| 02 41 00 | DIVISION 2-TEAR-OFFS | |||||||
| 1006 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES NOT INCLUDE INSULATION) | SQ | 2000 | $0.00 | ||||
| 1007 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 2" THICK | SQ | 2000 | $0.00 | ||||
| 1008 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION OVER 2" THICK | BF | 1000 | $0.00 | ||||
| 1009 | REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | $0.00 | ||||
| 1010 | REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | $0.00 | ||||
| 1011 | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 200 | $0.00 | ||||
| 1012 | DEMOLITION, HAULING, AND DISPOSAL OF AGGREGATE BALLAST. INCLUDE SPUDDING BACK AND VACUUMING LOOSE AGGREGATE FROM ENTIRE ROOF SURFACE. | SQ | 200 | $0.00 | ||||
| 1013 | REMOVE SINGLE PLY ROOFING (INCLUDING PVC, EPDM, PIB, TPO AND OTHER MEMBRANE ROOFING) DOWN TO THE DECK. INCLUDE MEMBRANE, PENETRATION & WALL FLASHINGS AND MEMBRANE FASTENERS. NOT TO INCLUDE INSULATION, CRICKETS AND INSULATION FASTENERS. | SQ | 200 | $0.00 | ||||
| DIVISION 2-ASBESTOS ABATEMENT/ LEAD CONTROLS | ||||||||
| 1014 | 02 82 14 | CLASS I AND/OR CLASS II ASBESTOS CONTAINING ROOF MATERIALS (ACRM) ROOF MEMBRANE. | SF | 500 | $0.00 | |||
| 1015 | 02 82 16 | CEMENTITIOUS ASBESTOS FIBER ROOF DECK/FORM BOARD | SF | 100 | $0.00 | |||
| 1016 | 02 83 13 | LEAD CONTROLS | SF | 100 | $0.00 | |||
| 04 01 20 | DIVISION 4-MASONRY | |||||||
| 1016 | WATER BLAST CLEAN EXISTING MASONRY SURFACE IN ACCOURDANCE WITH PAINT MANUFACTURER'S RECOMMENDATIONS. | SF | 500 | $0.00 | ||||
| 1017 | CONCRETE MASONRY UNITS TO INCLUDE GROUTING, TUCK POINTING, FORMWORK, AND SUPPORTS. PERFORM WORK IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. | SF | 200 | $0.00 | ||||
| 05 30 00 | DIVISION 5-STEEL ROOF DECK | |||||||
| 1018 | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 100 | $0.00 | ||||
| DIVISION 5-METALS | ||||||||
| 05 40 00 | COLD-FORMED METAL FRAMING | |||||||
| 1019 | COLD-FORMED METAL FRAMING MEMBERS OR SOFFIT FRAMING, TO INCLUDE SADDLES, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND NAILERS ATTACHED AT THE TOPS OF CONCRETE OR MASONRY CURBS, EXPANSION JOINTS AND ROOF EDGES. FRAMING MEMBERS ARE 4" TO 8" WIDE BY 18 GAUGE OR THINNER. | LF | 1000 | $0.00 | ||||
| 1020 | RETROFIT SUB-PURLIN AND/OR FORMED SHAPED FRAMING SYSTEM MECHANICALLY FASTENED TO EXISTING AND/OR SUBSTRATE IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS. MINIMUM 16 GAUGE THICKNESS | LF | 1000 | $0.00 | ||||
| 05 50 13 | METAL FABRICATION | |||||||
| 1021 | SHOP PRIMED STEEL MATERIALS INCLUDING BUT NOT LIMITED TO: PLATES, ANGLES, ANCHOR BOLTS, STEEL PIPE SLEEVES, WEDGE TYPE INSERTS, EXPANSION ANCHORS, FRAMING, SUPPORTS AND FABRICATED ITEMS FOR APPLICATIONS THAT ARE NOT SPECIFIED IN OTHER SPECIFICATION SECTIONS. | LB | 500 | $0.00 | ||||
| 05 51 00, 05 51 33 | STAIRS AND LADDERS | |||||||
| FABRICATE AND INSTALL ALUMINUM ROOF ACCESS STAIRS OR LADDERS | LB | 100 | $0.00 | |||||
| FABRICATE AND INSTALL GALVANIZED STEEL ROOF ACCESS STAIRS OR LADDERS | LB | 100 | $0.00 | |||||
| REMOVE AND DISPOSE OF EXISTING ACCESS STAIRS OR LADDERS | LB | 100 | $0.00 | |||||
| 05 52 00 | PIPE AND TUBE RAILINGS | |||||||
| 1022 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT ALUMINUM PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 200 | $0.00 | ||||
| 1023 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT GALVANIZED STEEL PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 200 | $0.00 | ||||
| 1024 | REMOVE AND DISPOSE OF PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 200 | $0.00 | ||||
| 06 10 00 | DIVISION 6-ROUGH CARPENTRY | |||||||
| 1025 | FURNISH AND INSTALL PRESERVATIVE TREATED WOOD ROOF NAILERS, WHICH INCLUDES WOOD SADDLES OR CRICKETS, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND WOOD NAILERS BOLTED TO TOPS OF CONCRETE OR MASONRY CURBS AND AT EXPANSION JOINTS | BF | 500 | $0.00 | ||||
| 1026 | REMOVE AND REPLACE 3/8", 5/8"OR 3/4" ROOF SHEATHING OR SOFFIT ON RESIDENTIAL UNITS | SF | 200 | $0.00 | ||||
| 1027 | REMOVE AND REPLACE ROOF DECKING FOR RESIDENTIAL UNITS, WHICH INCLUDES 1x OR 2x DECKING | SF | 200 | $0.00 | ||||
| 1028 | FURNISH AND INSTALL ROOFING LUMBER FOR RESIDENTIAL UNITS, WHICH INCLUDES RAFTERS, STUDS, PLATES, CAPS, COLLAR BEAMS, SLEEPERS, NAILING STRIPS, SILLS, HEADERS AND FASCIA | BF | 200 | $0.00 | ||||
| 07 22 00 | DIVISION 7-INSULATION | |||||||
| POLYISOCYANURATE BOARD INSULATION | ||||||||
| 1029 | 1" THICK, R5.7 | SQ | 200 | $0.00 | ||||
| 1030 | 1.5" THICK R8.6 | SQ | 100 | $0.00 | ||||
| 1031 | 2" THICK, R11.4 | SQ | 200 | $0.00 | ||||
| 1032 | 3" THICK, R17.1 | SQ | 200 | $0.00 | ||||
| 1033 | 4" THICK, R22.8 | SQ | 100 | $0.00 | ||||
| 1034 | 5" THICK, R28.5 | SQ | 1,000 | $0.00 | ||||
| 1035 | 5.5" THICK, R31.3 | SQ | 200 | $0.00 | ||||
| 1036 | TAPERED FILL INSULATION BOARD FOR DRAINAGE | BF | 75,000 | $0.00 | ||||
| 07 22 00 | PROTECTION BOARDS: | |||||||
| 1037 | GLASS MAT GYPSUM ROOF BOARD | SQ | 500 | $0.00 | ||||
| 1038 | HIGH DENSITY WOOD FIBER BOARD | SQ | 500 | $0.00 | ||||
| 1039 | FIBER CANTS | LF | 1,000 | $0.00 | ||||
| 1040 | WOOD CANTS | LF | 1,000 | $0.00 | ||||
| 1041 | SHEATING PAPER FOR WOOD DECKS | SQ | 50 | $0.00 | ||||
| 1042 | 07 21 16 | BATT ROOF INSULATION, R-19 | SF | 1,000 | $0.00 | |||
| 1040 | BATT ROOF INSULATION, R-30 | SF | 1,000 | $0.00 | ||||
| 1043 | 07 61 14 | METAL ROOF INSULATION, R30 | SQ | 200 | $0.00 | |||
| 07 31 13 | DIVISION 7-SHINGLE ROOFING SYSTEMS | |||||||
| 1041 | FURNISH AND INSTALL NEW 3-TAB MINERAL SURFACED ASPHALT STRIP SHINGLE SYSTEM | SQ | 300 | $0.00 | ||||
| 1042 | FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL ASHPALT SHINGLE SYSTEM | SQ | 100 | $0.00 | ||||
| 1043 | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW ASPHALT STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS | SQ | 10 | $0.00 | ||||
| 1044 | ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER) | SQ | 50 | $0.00 | ||||
| multiple | DIVISION 7-UNDERLAYMENT | |||||||
| 1045 | FELT, ASPHALT SATURATED, 30 POUND | SQ | 500 | $0.00 | ||||
| 1046 | SELF ADHERING LEAK BARRIER (PEAL AND STICK) | SQ | 500 | $0.00 | ||||
| 07 52 00 | DIVISION 7-BITUMINOUS ROOFING (BURS) | |||||||
| 1047 | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 1000 | $0.00 | ||||
| 1048 | REMOVE AND REPLACE PITCH PAN | EA | 30 | $0.00 | ||||
| FOR RESIDENTIAL UNITS | ||||||||
| 1048 | SINGLE-PLY SBS MODIFIED CAP SHEET FOR RESIDENTIAL UNITS | SQ | 250 | $0.00 | ||||
| 07 01 50 | DIVISION 7-PARTIAL BURS REPAIRS | |||||||
| 1049 | REPAIRS BLISTERS | SF | 500 | $0.00 | ||||
| 1050 | REPAIR SPLITS | LF | 200 | $0.00 | ||||
| 1051 | REPAIR RIDGES | LF | 200 | $0.00 | ||||
| 1052 | APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREAS | SF | 500 | $0.00 | ||||
| 07 31 13 | DIVISION 7-PREPARED ROLL ROOFING | |||||||
| 1053 | FURNISH AND INSTALL NEW MINERAL SURFACED ASPHALT PREPARED ROLL ROOFING | SQ | 50 | $0.00 | ||||
| 1054 | CUT-OUT AND PATCH ROLL ROOFING | SQ | 5 | $0.00 | ||||
| 07 54 19 | DIVISION 7-POLYVINYL-CHLORIDE ROOFING | |||||||
| 1055 | FURNISH/INSTALL FULLY ADHERED PVC SYSTEM- 72 MILS | SQ | 1000 | $0.00 | ||||
| 1056 | FURNISH/INSTALL MECHANICALLY FASTENED PVC SYSTEM- 72 MIL | SQ | 1000 | $0.00 | ||||
| 1057 | PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 500 | $0.00 | ||||
| 1058 | PVC LAMINATED METAL FLASHING 18.1" TO 36" STRETCH OUT | LF | 500 | $0.00 | ||||
| 1059 | PVC VENT BOOTS | EA | 50 | $0.00 | ||||
| 1060 | PVC UNIVERSAL CORNERS | EA | 200 | $0.00 | ||||
| 1061 | PATCH AND REPAIR PVC SYSTEM | SF | 90 | $0.00 | ||||
| 07 14 00 | DIVISION 7-FLUID APPLIED WATERPROOFING | |||||||
| 1062 | FLUID APPLIED COATING SYSTEM FOR METAL ROOFS | SQ | 100 | $0.00 | ||||
| 1063 | ENERGY STAR RATED COATING SYSTEM APPLIED TO NEW BUR ROOFING WITH MODIFIED CAP SHEET | SQ | 50 | $0.00 | ||||
| 1064 | ELASTOMERIC COATING FOR ROOF REPAIRS | SQ | 10 | $0.00 | ||||
| multiple | DIVISION 7-TRAFFIC-BEARING ROOF DECK SURFACING | |||||||
| 1065 | TRAFFIC-BEARING ROOF SURFACING SYSTEM | SQ | 10 | $0.00 | ||||
| 07 60 00 | DIVISION 7-SHEET METAL WORK, GENERAL | |||||||
| FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION) | ||||||||
| 1066 | GALVANIZED METAL, 4"- 5" | LF | 500 | $0.00 | ||||
| 1067 | GALVANIZED METAL, 6" - 7" | LF | 100 | $0.00 | ||||
| 1068 | ALUMINUM, 4" - 5" | LF | 500 | $0.00 | ||||
| 1069 | ALUMINUM, 6" - 7" | LF | 100 | $0.00 | ||||
| 1070 | 2-PIECE GALVANIZED METAL, 7" - 10" | LF | 50 | $0.00 | ||||
| 1071 | 2-PIECE GALVANIZED METAL, 10" - 12" | LF | 50 | $0.00 | ||||
| 1072 | 2-PIECE ALUMINUM, 7" - 10" | LF | 50 | $0.00 | ||||
| 1073 | 2-PIECE ALUMINUM, 10" - 12" | LF | 50 | $0.00 | ||||
| FURNISH AND INSTALL: | ||||||||
| 1074 | GALVANIZED METAL DRIP EDGE | LF | 500 | $0.00 | ||||
| 1075 | GALVANIZED METAL COUNTERFLASHING | SF | 400 | $0.00 | ||||
| 1076 | GALVANIZED METAL VALLEY FLASHING | SF | 400 | $0.00 | ||||
| 1077 | GALVANIZED METAL STEP FLASHING | SF | 200 | $0.00 | ||||
| 1078 | GALVANIZED METAL BASE FLASHING | SF | 200 | $0.00 | ||||
| 1079 | GALVANIZED METAL FLASHING- FLAT SHEET | SF | 200 | $0.00 | ||||
| 1080 | GALVANIZED METAL CAP FLASHING | SF | 200 | $0.00 | ||||
| 1081 | ALUMINUM DRIP EDGE | LF | 500 | $0.00 | ||||
| 1082 | ALUMINUM COUNTERFLASHING | SF | 200 | $0.00 | ||||
| 1083 | ALUMINUM VALLEY FLASHING | SF | 200 | $0.00 | ||||
| 1084 | ALUMINUM STEP FLASHING | SF | 200 | $0.00 | ||||
| 1085 | ALUMINUM BASE FLASHING | SF | 200 | $0.00 | ||||
| 1086 | ALUMINUM FLASHING - FLAT SHEET | SF | 200 | $0.00 | ||||
| 1087 | ALUMINUM CAP FLASHING | SF | 200 | $0.00 | ||||
| 1088 | METAL RIDGE VENT | LF | 200 | $0.00 | ||||
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT: | ||||||||
| 1089 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 100 | $0.00 | ||||
| 1090 | ALUMINUM CAPPED CURB | LF | 100 | $0.00 | ||||
| 1091 | GALVANIZED CAPPED CURB | LF | 100 | $0.00 | ||||
| 1092 | REMOVE AND REPLACE VENTILATOR, ROOFTOP | EA | 5 | $0.00 | ||||
| 1093 | REMOVE AND REPLACE VENTILATOR, RIDGE | LF | 40 | $0.00 | ||||
| 1094 | REMOVE AND REPLACE VENTILATOR, GABLE | EA | 2 | $0.00 | ||||
| 1095 | REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHED | EA | 2 | $0.00 | ||||
| 1096 | REMOVE AND REPLACE ROOF SCUTTLE | EA | 2 | $0.00 | ||||
| 07 42 13 | DIVISION 7-METAL WALL PANELS | |||||||
| 1097 | FURNISH AND INSTALL WALL PANELS | SF | 250 | $0.00 | ||||
| 1098 | FURNISH AND INSTALL FABRICATED WALL PANEL ASSEMBLY (INCLUDING INSULATION) | SF | 100 | $0.00 | ||||
| DIVISION 7-GUTTERS AND DOWNSPOUTS | ||||||||
| 1099 | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 750 | $0.00 | ||||
| FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC. | ||||||||
| 1100 | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 200 | $0.00 | ||||
| 1101 | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 1000 | $0.00 | ||||
| 1102 | ALUMINUM, 4" X 5" | LF | 1000 | $0.00 | ||||
| 1103 | ALUMINUM, 5" X 7" | LF | 100 | $0.00 | ||||
| FURNISH & INSTALL NEW DOWNSPOUTS, INCLUDES BRACKETS, ETC. | ||||||||
| 1104 | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 500 | $0.00 | ||||
| 1105 | ALUMINUM, 3" X 4" | LF | 100 | $0.00 | ||||
| 1106 | FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 20 | $0.00 | ||||
| 1107 | INSTALL NEW THROUGH WALL SCUPPERS | EA | 10 | $0.00 | ||||
| 05 40 00 | DIVISION 7-MANUFACTURED ROOF FRAMING SYSTEM | |||||||
| 1108 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE <= 100 SQ | SQ | 150 | $0.00 | ||||
| 1109 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE =>100 SQ | SQ | 150 | $0.00 | ||||
| DIVISION 7-STANDING SEAM METAL ROOF SYSTEM | ||||||||
| 1110 | 07 41 13 | NEW METAL ROOF PANELS, ARCHITECTURAL/NON-STRUCTURAL PER SPEC UFGS 07 41 13 | SQ | 400 | $0.00 | |||
| 0169 | 07 61 14 | NEW STEEL STANDING SEAM METAL ROOFING, STRUCTURAL, PER SPEC. UFGS 07 61 14 | SQ | 400 | $0.00 | |||
| 0170 | 07 61 15 | NEW ALUMINUM STANDING SEAM METAL ROOF, STRUCTURAL, PER SPEC. UFGS 07 61 15 | SQ | 100 | $0.00 | |||
| 0171 | FASCIA PANEL SYSTEM | SF | 750 | $0.00 | ||||
| 0172 | NON-PERFORATED SOFFIT PANEL | SF | 500 | $0.00 | ||||
| 0173 | PERFORATED SOFFIT PANEL | SF | 500 | $0.00 | ||||
| 0174 | FELT OVER WOOD DECKS | SQ | 100 | $0.00 | ||||
| 07 92 00 | DIVISION 7-CAULKING AND SEALANTS | |||||||
| 0175 | REMOVE EXISTING CAULKING, CLEAN JOINT | LF | 1000 | $0.00 | ||||
| 0176 | SILICONE CAULKING/SEALANT | LF | 500 | $0.00 | ||||
| 0177 | CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1, OR APPROVED EQUAL) | LF | 500 | $0.00 | ||||
| 09 90 00 | DIVISION 9-PAINTING | |||||||
| 0178 | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | 1,000 | $0.00 | ||||
| 0179 | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 1,000 | $0.00 | ||||
| 22 00 00 | DIVISION 15-ROOF DRAINS | |||||||
| 0180 | REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 5 | $0.00 | ||||
| 0181 | REMOVE AND REPLACE EXISTING ROOF DRAIN, INCLUDES NEW CAST IRON DOME STRAINER | EA | 20 | $0.00 | ||||
| 26 41 00 | DIVISION 16-LIGHTING PROTECTION | |||||||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERS | ||||||||
| 0182 | REMOVE AND REINSTALL EXISTING CONDUCTOR | LF | 200 | $0.00 | ||||
| 0183 | REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPS | EA | 25 | $0.00 | ||||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTNING PROTECTION SYSTEM | ||||||||
| 0184 | AIR TERMINALS, INCLUDES COPPER BASE FOR NON-METAL ROOFS | EA | 20 | $0.00 | ||||
| 0185 | AIR TERMINALS, INCLUDES ALUMINUM BASE FOR METAL ROOFS | EA | 20 | $0.00 | ||||
| 0186 | CONDUCTORS | LF | 300 | $0.00 | ||||
| 0187 | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 100 | $0.00 | ||||
| 0188 | CONNECTORS | EA | 20 | $0.00 | ||||
| 0189 | COUNTERPOISE CONDUCTOR | LF | 1000 | $0.00 | ||||
| 0190 | GROUNDING RODS, 3/4" DIAMETER x 60' LONG | EA | 10 | $0.00 | ||||
| 0191 | SURGE PROTECTION | EA | 1 | $0.00 | ||||
| 0192 | FURNISH AND INSTALL GROUND ACCESS PVC TEST WELL, 12" I.D. X 24" LONG WITH 1/4" GALVANIZED FRICTION FIT COVER WITH THE WORD "GROUND" ENGREAVED ON TOP OF THE COVER | EA | 10 | $0.00 | ||||
| 0193 | UL SITE INSPECTION | EA | 10 | $0.00 | ||||
| MISCELLANEOUS ROOFING ITEMS | ||||||||
| 0194 | FURNISH AND INSTALL PERMANENT FALL PROTECTION ANCHORAGE (PER EACH ANCHOR POINT) | EA | 50 | $0.00 | ||||
| 0195 | EXTEND PLUMBING VENTS | LF | 40 | $0.00 | ||||
| 0196 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 30 | $0.00 | ||||
| 0197 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR) | EA | 40 | $0.00 | ||||
| 0198 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH COLLAR TYPE FLASHING | EA | 40 | $0.00 | ||||
| 0199 | REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 200 | $0.00 | ||||
| 0200 | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKS | SQ | 200 | $0.00 | ||||
| 0201 | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP) | EA | 10 | $0.00 | ||||
| 0202 | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 100 | $0.00 | ||||
| 0203 | ROLL COIL RIDGE VENT | LF | 100 | $0.00 | ||||
| 0204 | SPUD EXISTING ROOF TO INSULATION | SQ | 200 | $0.00 | ||||
| 0205 | CUT AND PATCH CONCRETE | LF | 1000 | $0.00 | ||||
| 0206 | TRENCH AND BACKFILL | LF | 1000 | $0.00 | ||||
| 0207 | CONCRETE SPLASH BLOCKS | EA | 50 | $0.00 | ||||
| 0208 | TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREA | EA | 10 | $0.00 | ||||
| 0209 | MOISTURE INSPECTION BY THERMAL IMAGING SURVEY | SF | 1000 | $0.00 | ||||
| 0210 | AS-BUILT DRAWINGS PER SPEC. NO. 01 11 00 | JOB | 10 | $0.00 | ||||
| 0211 | ENGINEERING RATE STRUCTURAL | HR | 20 | $0.00 | ||||
| 0212 | ENGINEERING RATE STRUCTURAL - FALL PROTECTION | JOB | 40 | $0.00 | ||||
| 0213 | MECHANICAL SUBCONTRACTOR | HR | 20 | $0.00 | ||||
| 0214 | ELECTRICAL SUBCONTRACTOR | HR | 20 | $0.00 | ||||
| 0215 | LABOR RATE - MISCELLANEOUS WORK | MH | 100 | $0.00 | ||||
| SPECIAL CONDITIONS AND CIRCUMSTANCES | ||||||||
| 0216 | HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOB | CSQ | 5 | $0.00 | ||||
| Subtotal | $0.00 | |||||||
| MODIFIERS | ||||||||
| 0217 | MULTIPLIER % TO BE ADDED TO TOTAL FOR GENERAL PROJECT REQUIREMENTS, i.e. MOBILIZATION/DEMOBILIZATION, EQUIPMENT RENTAL, ONSITE BATHROOM, SAFETY PROCEDURES, ETC. | % | $0.00 | |||||
| Subtotal | $0.00 | |||||||
| 0218 | MULTIPLIER % TO BE ADDED TO TOTAL FOR URGENT DELIVERY ORDER (UDO)-TEMPORARY DRY-IN WORK ONLY | % | $0.00 | |||||
| OPTION BASE YEAR TOTAL | $0.00 |
&"Arial,Bold"&10Page &P of &N &"Arial,Bold"&10&A - &F
YEAR TWO
| 7-Feb-17 | |
| ROOFING BID SCHEDULE | |
| IDIQ 2017-2022 | |
| Project No. FTFA 16-7000 Spec. No. 16AD | |
| 0.00 |
| BASIC YEAR | Contractor | |||||||
| LINE ITEM | SPEC | DESCRIPTION | Unit | EST. QTY. | UNIT PRICE | EST. TOTAL PRICE | UNIT PRICE | EST. TOTAL PRICE |
| 02 41 00 | DIVISION2-SELECTIVE DEMOLITION | |||||||
| 2001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK | LF | 1000 | $0.00 | ||||
| 2002 | REMOVE AND REPLACE WOOD DECKING | SF | 500 | $0.00 | ||||
| 2003 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING | SF | 2000 | $0.00 | ||||
| 2004 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 2" THICK | LF | 1000 | $0.00 | ||||
| 2005 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | SF | 500 | $0.00 | ||||
| 02 41 00 | DIVISION 2-TEAR-OFFS | |||||||
| 2006 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES NOT INCLUDE INSULATION) | SQ | 2000 | $0.00 | ||||
| 2007 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 2" THICK | SQ | 2000 | $0.00 | ||||
| 2008 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION OVER 2" THICK | BF | 1000 | $0.00 | ||||
| 2009 | REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | $0.00 | ||||
| 2010 | REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | $0.00 | ||||
| 2011 | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 200 | $0.00 | ||||
| 2012 | DEMOLITION, HAULING, AND DISPOSAL OF AGGREGATE BALLAST. INCLUDE SPUDDING BACK AND VACUUMING LOOSE AGGREGATE FROM ENTIRE ROOF SURFACE. | SQ | 200 | $0.00 | ||||
| 2013 | REMOVE SINGLE PLY ROOFING (INCLUDING PVC, EPDM, PIB, TPO AND OTHER MEMBRANE ROOFING) DOWN TO THE DECK. INCLUDE MEMBRANE, PENETRATION & WALL FLASHINGS AND MEMBRANE FASTENERS. NOT TO INCLUDE INSULATION, CRICKETS AND INSULATION FASTENERS. | SQ | 200 | $0.00 | ||||
| DIVISION 2-ASBESTOS ABATEMENT/ LEAD CONTROLS | ||||||||
| 2014 | 02 82 14 | CLASS I AND/OR CLASS II ASBESTOS CONTAINING ROOF MATERIALS (ACRM) ROOF MEMBRANE. | SF | 500 | $0.00 | |||
| 2015 | 02 82 16 | CEMENTITIOUS ASBESTOS FIBER ROOF DECK/FORM BOARD | SF | 100 | $0.00 | |||
| 2016 | 02 83 13 | LEAD CONTROLS | SF | 100 | $0.00 | |||
| 04 01 20 | DIVISION 4-MASONRY | |||||||
| 2016 | WATER BLAST CLEAN EXISTING MASONRY SURFACE IN ACCOURDANCE WITH PAINT MANUFACTURER'S RECOMMENDATIONS. | SF | 500 | $0.00 | ||||
| 2017 | CONCRETE MASONRY UNITS TO INCLUDE GROUTING, TUCK POINTING, FORMWORK, AND SUPPORTS. PERFORM WORK IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. | SF | 200 | $0.00 | ||||
| 05 30 00 | DIVISION 5-STEEL ROOF DECK | |||||||
| 2018 | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 100 | $0.00 | ||||
| DIVISION 5-METALS | ||||||||
| 05 40 00 | COLD-FORMED METAL FRAMING | |||||||
| 2019 | COLD-FORMED METAL FRAMING MEMBERS OR SOFFIT FRAMING, TO INCLUDE SADDLES, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND NAILERS ATTACHED AT THE TOPS OF CONCRETE OR MASONRY CURBS, EXPANSION JOINTS AND ROOF EDGES. FRAMING MEMBERS ARE 4" TO 8" WIDE BY 18 GAUGE OR THINNER. | LF | 1000 | $0.00 | ||||
| 2020 | RETROFIT SUB-PURLIN AND/OR FORMED SHAPED FRAMING SYSTEM MECHANICALLY FASTENED TO EXISTING AND/OR SUBSTRATE IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS. MINIMUM 16 GAUGE THICKNESS | LF | 1000 | $0.00 | ||||
| 05 50 13 | METAL FABRICATION | |||||||
| 2021 | SHOP PRIMED STEEL MATERIALS INCLUDING BUT NOT LIMITED TO: PLATES, ANGLES, ANCHOR BOLTS, STEEL PIPE SLEEVES, WEDGE TYPE INSERTS, EXPANSION ANCHORS, FRAMING, SUPPORTS AND FABRICATED ITEMS FOR APPLICATIONS THAT ARE NOT SPECIFIED IN OTHER SPECIFICATION SECTIONS. | LB | 500 | $0.00 | ||||
| 05 51 00, 05 51 33 | STAIRS AND LADDERS | |||||||
| FABRICATE AND INSTALL ALUMINUM ROOF ACCESS STAIRS OR LADDERS | LB | 100 | $0.00 | |||||
| FABRICATE AND INSTALL GALVANIZED STEEL ROOF ACCESS STAIRS OR LADDERS | LB | 100 | $0.00 | |||||
| REMOVE AND DISPOSE OF EXISTING ACCESS STAIRS OR LADDERS | LB | 100 | $0.00 | |||||
| 05 52 00 | PIPE AND TUBE RAILINGS | |||||||
| 2022 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT ALUMINUM PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 200 | $0.00 | ||||
| 2023 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT GALVANIZED STEEL PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 200 | $0.00 | ||||
| 2024 | REMOVE AND DISPOSE OF PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 200 | $0.00 | ||||
| 06 10 00 | DIVISION 6-ROUGH CARPENTRY | |||||||
| 2025 | FURNISH AND INSTALL PRESERVATIVE TREATED WOOD ROOF NAILERS, WHICH INCLUDES WOOD SADDLES OR CRICKETS, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND WOOD NAILERS BOLTED TO TOPS OF CONCRETE OR MASONRY CURBS AND AT EXPANSION JOINTS | BF | 500 | $0.00 | ||||
| 2026 | REMOVE AND REPLACE 3/8", 5/8"OR 3/4" ROOF SHEATHING OR SOFFIT ON RESIDENTIAL UNITS | SF | 200 | $0.00 | ||||
| 2027 | REMOVE AND REPLACE ROOF DECKING FOR RESIDENTIAL UNITS, WHICH INCLUDES 1x OR 2x DECKING | SF | 200 | $0.00 | ||||
| 2028 | FURNISH AND INSTALL ROOFING LUMBER FOR RESIDENTIAL UNITS, WHICH INCLUDES RAFTERS, STUDS, PLATES, CAPS, COLLAR BEAMS, SLEEPERS, NAILING STRIPS, SILLS, HEADERS AND FASCIA | BF | 200 | $0.00 | ||||
| 07 22 00 | DIVISION 7-INSULATION | |||||||
| POLYISOCYANURATE BOARD INSULATION | ||||||||
| 2029 | 1" THICK, R5.7 | SQ | 200 | $0.00 | ||||
| 2030 | 1.5" THICK R8.6 | SQ | 100 | $0.00 | ||||
| 2031 | 2" THICK, R11.4 | SQ | 200 | $0.00 | ||||
| 2032 | 3" THICK, R17.1 | SQ | 200 | $0.00 | ||||
| 2033 | 4" THICK, R22.8 | SQ | 100 | $0.00 | ||||
| 2034 | 5" THICK, R28.5 | SQ | 1,000 | $0.00 | ||||
| 2035 | 5.5" THICK, R31.3 | SQ | 200 | $0.00 | ||||
| 2036 | TAPERED FILL INSULATION BOARD FOR DRAINAGE | BF | 75,000 | $0.00 | ||||
| 07 22 00 | PROTECTION BOARDS: | |||||||
| 2037 | GLASS MAT GYPSUM ROOF BOARD | SQ | 500 | $0.00 | ||||
| 2038 | HIGH DENSITY WOOD FIBER BOARD | SQ | 500 | $0.00 | ||||
| 2039 | FIBER CANTS | LF | 1,000 | $0.00 | ||||
| 2040 | WOOD CANTS | LF | 1,000 | $0.00 | ||||
| 2041 | SHEATING PAPER FOR WOOD DECKS | SQ | 50 | $0.00 | ||||
| 2042 | 07 21 16 | BATT ROOF INSULATION, R-19 | SF | 1,000 | $0.00 | |||
| 2040 | BATT ROOF INSULATION, R-30 | SF | 1,000 | $0.00 | ||||
| 2043 | 07 61 14 | METAL ROOF INSULATION, R30 | SQ | 200 | $0.00 | |||
| 07 31 13 | DIVISION 7-SHINGLE ROOFING SYSTEMS | |||||||
| 2041 | FURNISH AND INSTALL NEW 3-TAB MINERAL SURFACED ASPHALT STRIP SHINGLE SYSTEM | SQ | 300 | $0.00 | ||||
| 2042 | FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL ASHPALT SHINGLE SYSTEM | SQ | 100 | $0.00 | ||||
| 2043 | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW ASPHALT STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS | SQ | 10 | $0.00 | ||||
| 2044 | ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER) | SQ | 50 | $0.00 | ||||
| multiple | DIVISION 7-UNDERLAYMENT | |||||||
| 2045 | FELT, ASPHALT SATURATED, 30 POUND | SQ | 500 | $0.00 | ||||
| 2046 | SELF ADHERING LEAK BARRIER (PEAL AND STICK) | SQ | 500 | $0.00 | ||||
| 07 52 00 | DIVISION 7-BITUMINOUS ROOFING (BURS) | |||||||
| 2047 | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 1000 | $0.00 | ||||
| 2048 | REMOVE AND REPLACE PITCH PAN | EA | 30 | $0.00 | ||||
| FOR RESIDENTIAL UNITS | ||||||||
| 2048 | SINGLE-PLY SBS MODIFIED CAP SHEET FOR RESIDENTIAL UNITS | SQ | 250 | $0.00 | ||||
| 07 01 50 | DIVISION 7-PARTIAL BURS REPAIRS | |||||||
| 2049 | REPAIRS BLISTERS | SF | 500 | $0.00 | ||||
| 2050 | REPAIR SPLITS | LF | 200 | $0.00 | ||||
| 2051 | REPAIR RIDGES | LF | 200 | $0.00 | ||||
| 2052 | APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREAS | SF | 500 | $0.00 | ||||
| 07 31 13 | DIVISION 7-PREPARED ROLL ROOFING | |||||||
| 2053 | FURNISH AND INSTALL NEW MINERAL SURFACED ASPHALT PREPARED ROLL ROOFING | SQ | 50 | $0.00 | ||||
| 2054 | CUT-OUT AND PATCH ROLL ROOFING | SQ | 5 | $0.00 | ||||
| 07 54 19 | DIVISION 7-POLYVINYL-CHLORIDE ROOFING | |||||||
| 2055 | FURNISH/INSTALL FULLY ADHERED PVC SYSTEM- 72 MILS | SQ | 1000 | $0.00 | ||||
| 2056 | FURNISH/INSTALL MECHANICALLY FASTENED PVC SYSTEM- 72 MIL | SQ | 1000 | $0.00 | ||||
| 2057 | PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 500 | $0.00 | ||||
| 2058 | PVC LAMINATED METAL FLASHING 18.1" TO 36" STRETCH OUT | LF | 500 | $0.00 | ||||
| 2059 | PVC VENT BOOTS | EA | 50 | $0.00 | ||||
| 2060 | PVC UNIVERSAL CORNERS | EA | 200 | $0.00 | ||||
| 2061 | PATCH AND REPAIR PVC SYSTEM | SF | 90 | $0.00 | ||||
| 07 14 00 | DIVISION 7-FLUID APPLIED WATERPROOFING | |||||||
| 2062 | FLUID APPLIED COATING SYSTEM FOR METAL ROOFS | SQ | 100 | $0.00 | ||||
| 2063 | ENERGY STAR RATED COATING SYSTEM APPLIED TO NEW BUR ROOFING WITH MODIFIED CAP SHEET | SQ | 50 | $0.00 | ||||
| 2064 | ELASTOMERIC COATING FOR ROOF REPAIRS | SQ | 10 | $0.00 | ||||
| multiple | DIVISION 7-TRAFFIC-BEARING ROOF DECK SURFACING | |||||||
| 2065 | TRAFFIC-BEARING ROOF SURFACING SYSTEM | SQ | 10 | $0.00 | ||||
| 07 60 00 | DIVISION 7-SHEET METAL WORK, GENERAL | |||||||
| FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION) | ||||||||
| 2066 | GALVANIZED METAL, 4"- 5" | LF | 500 | $0.00 | ||||
| 2067 | GALVANIZED METAL, 6" - 7" | LF | 100 | $0.00 | ||||
| 2068 | ALUMINUM, 4" - 5" | LF | 500 | $0.00 | ||||
| 2069 | ALUMINUM, 6" - 7" | LF | 100 | $0.00 | ||||
| 2070 | 2-PIECE GALVANIZED METAL, 7" - 10" | LF | 50 | $0.00 | ||||
| 2071 | 2-PIECE GALVANIZED METAL, 10" - 12" | LF | 50 | $0.00 | ||||
| 2072 | 2-PIECE ALUMINUM, 7" - 10" | LF | 50 | $0.00 | ||||
| 2073 | 2-PIECE ALUMINUM, 10" - 12" | LF | 50 | $0.00 | ||||
| FURNISH AND INSTALL: | ||||||||
| 2074 | GALVANIZED METAL DRIP EDGE | LF | 500 | $0.00 | ||||
| 2075 | GALVANIZED METAL COUNTERFLASHING | SF | 400 | $0.00 | ||||
| 2076 | GALVANIZED METAL VALLEY FLASHING | SF | 400 | $0.00 | ||||
| 2077 | GALVANIZED METAL STEP FLASHING | SF | 200 | $0.00 | ||||
| 2078 | GALVANIZED METAL BASE FLASHING | SF | 200 | $0.00 | ||||
| 2079 | GALVANIZED METAL FLASHING- FLAT SHEET | SF | 200 | $0.00 | ||||
| 2080 | GALVANIZED METAL CAP FLASHING | SF | 200 | $0.00 | ||||
| 2081 | ALUMINUM DRIP EDGE | LF | 500 | $0.00 | ||||
| 2082 | ALUMINUM COUNTERFLASHING | SF | 200 | $0.00 | ||||
| 2083 | ALUMINUM VALLEY FLASHING | SF | 200 | $0.00 | ||||
| 2084 | ALUMINUM STEP FLASHING | SF | 200 | $0.00 | ||||
| 2085 | ALUMINUM BASE FLASHING | SF | 200 | $0.00 | ||||
| 2086 | ALUMINUM FLASHING - FLAT SHEET | SF | 200 | $0.00 | ||||
| 2087 | ALUMINUM CAP FLASHING | SF | 200 | $0.00 | ||||
| 2088 | METAL RIDGE VENT | LF | 200 | $0.00 | ||||
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT: | ||||||||
| 2089 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 100 | $0.00 | ||||
| 2090 | ALUMINUM CAPPED CURB | LF | 100 | $0.00 | ||||
| 2091 | GALVANIZED CAPPED CURB | LF | 100 | $0.00 | ||||
| 2092 | REMOVE AND REPLACE VENTILATOR, ROOFTOP | EA | 5 | $0.00 | ||||
| 2093 | REMOVE AND REPLACE VENTILATOR, RIDGE | LF | 40 | $0.00 | ||||
| 2094 | REMOVE AND REPLACE VENTILATOR, GABLE | EA | 2 | $0.00 | ||||
| 2095 | REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHED | EA | 2 | $0.00 | ||||
| 2096 | REMOVE AND REPLACE ROOF SCUTTLE | EA | 2 | $0.00 | ||||
| 07 42 13 | DIVISION 7-METAL WALL PANELS | |||||||
| 2097 | FURNISH AND INSTALL WALL PANELS | SF | 250 | $0.00 | ||||
| 2098 | FURNISH AND INSTALL FABRICATED WALL PANEL ASSEMBLY (INCLUDING INSULATION) | SF | 100 | $0.00 | ||||
| DIVISION 7-GUTTERS AND DOWNSPOUTS | ||||||||
| 2099 | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 750 | $0.00 | ||||
| FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC. | ||||||||
| 2100 | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 200 | $0.00 | ||||
| 2101 | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 1000 | $0.00 | ||||
| 2102 | ALUMINUM, 4" X 5" | LF | 1000 | $0.00 | ||||
| 2103 | ALUMINUM, 5" X 7" | LF | 100 | $0.00 | ||||
| FURNISH & INSTALL NEW DOWNSPOUTS, INCLUDES BRACKETS, ETC. | ||||||||
| 2104 | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 500 | $0.00 | ||||
| 2105 | ALUMINUM, 3" X 4" | LF | 100 | $0.00 | ||||
| 2106 | FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 20 | $0.00 | ||||
| 2107 | INSTALL NEW THROUGH WALL SCUPPERS | EA | 10 | $0.00 | ||||
| 05 40 00 | DIVISION 7-MANUFACTURED ROOF FRAMING SYSTEM | |||||||
| 2108 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE <= 100 SQ | SQ | 150 | $0.00 | ||||
| 2109 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE =>100 SQ | SQ | 150 | $0.00 | ||||
| DIVISION 7-STANDING SEAM METAL ROOF SYSTEM | ||||||||
| 2110 | 07 41 13 | NEW METAL ROOF PANELS, ARCHITECTURAL/NON-STRUCTURAL PER SPEC UFGS 07 41 13 | SQ | 400 | $0.00 | |||
| 0169 | 07 61 14 | NEW STEEL STANDING SEAM METAL ROOFING, STRUCTURAL, PER SPEC. UFGS 07 61 14 | SQ | 400 | $0.00 | |||
| 0170 | 07 61 15 | NEW ALUMINUM STANDING SEAM METAL ROOF, STRUCTURAL, PER SPEC. UFGS 07 61 15 | SQ | 100 | $0.00 | |||
| 0171 | FASCIA PANEL SYSTEM | SF | 750 | $0.00 | ||||
| 0172 | NON-PERFORATED SOFFIT PANEL | SF | 500 | $0.00 | ||||
| 0173 | PERFORATED SOFFIT PANEL | SF | 500 | $0.00 | ||||
| 0174 | FELT OVER WOOD DECKS | SQ | 100 | $0.00 | ||||
| 07 92 00 | DIVISION 7-CAULKING AND SEALANTS | |||||||
| 0175 | REMOVE EXISTING CAULKING, CLEAN JOINT | LF | 1000 | $0.00 | ||||
| 0176 | SILICONE CAULKING/SEALANT | LF | 500 | $0.00 | ||||
| 0177 | CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1, OR APPROVED EQUAL) | LF | 500 | $0.00 | ||||
| 09 90 00 | DIVISION 9-PAINTING | |||||||
| 0178 | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | 1,000 | $0.00 | ||||
| 0179 | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 1,000 | $0.00 | ||||
| 22 00 00 | DIVISION 15-ROOF DRAINS | |||||||
| 0180 | REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 5 | $0.00 | ||||
| 0181 | REMOVE AND REPLACE EXISTING ROOF DRAIN, INCLUDES NEW CAST IRON DOME STRAINER | EA | 20 | $0.00 | ||||
| 26 41 00 | DIVISION 16-LIGHTING PROTECTION | |||||||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERS | ||||||||
| 0182 | REMOVE AND REINSTALL EXISTING CONDUCTOR | LF | 200 | $0.00 | ||||
| 0183 | REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPS | EA | 25 | $0.00 | ||||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTNING PROTECTION SYSTEM | ||||||||
| 0184 | AIR TERMINALS, INCLUDES COPPER BASE FOR NON-METAL ROOFS | EA | 20 | $0.00 | ||||
| 0185 | AIR TERMINALS, INCLUDES ALUMINUM BASE FOR METAL ROOFS | EA | 20 | $0.00 | ||||
| 0186 | CONDUCTORS | LF | 300 | $0.00 | ||||
| 0187 | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 100 | $0.00 | ||||
| 0188 | CONNECTORS | EA | 20 | $0.00 | ||||
| 0189 | COUNTERPOISE CONDUCTOR | LF | 1000 | $0.00 | ||||
| 0190 | GROUNDING RODS, 3/4" DIAMETER x 60' LONG | EA | 10 | $0.00 | ||||
| 0191 | SURGE PROTECTION | EA | 1 | $0.00 | ||||
| 0192 | FURNISH AND INSTALL GROUND ACCESS PVC TEST WELL, 12" I.D. X 24" LONG WITH 1/4" GALVANIZED FRICTION FIT COVER WITH THE WORD "GROUND" ENGREAVED ON TOP OF THE COVER | EA | 10 | $0.00 | ||||
| 0193 | UL SITE INSPECTION | EA | 10 | $0.00 | ||||
| MISCELLANEOUS ROOFING ITEMS | ||||||||
| 0194 | FURNISH AND INSTALL PERMANENT FALL PROTECTION ANCHORAGE (PER EACH ANCHOR POINT) | EA | 50 | $0.00 | ||||
| 0195 | EXTEND PLUMBING VENTS | LF | 40 | $0.00 | ||||
| 0196 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 30 | $0.00 | ||||
| 0197 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR) | EA | 40 | $0.00 | ||||
| 0198 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH COLLAR TYPE FLASHING | EA | 40 | $0.00 | ||||
| 0199 | REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 200 | $0.00 | ||||
| 0200 | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKS | SQ | 200 | $0.00 | ||||
| 0201 | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP) | EA | 10 | $0.00 | ||||
| 0202 | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 100 | $0.00 | ||||
| 0203 | ROLL COIL RIDGE VENT | LF | 100 | $0.00 | ||||
| 0204 | SPUD EXISTING ROOF TO INSULATION | SQ | 200 | $0.00 | ||||
| 0205 | CUT AND PATCH CONCRETE | LF | 1000 | $0.00 | ||||
| 0206 | TRENCH AND BACKFILL | LF | 1000 | $0.00 | ||||
| 0207 | CONCRETE SPLASH BLOCKS | EA | 50 | $0.00 | ||||
| 0208 | TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREA | EA | 10 | $0.00 | ||||
| 0209 | MOISTURE INSPECTION BY THERMAL IMAGING SURVEY | SF | 1000 | $0.00 | ||||
| 0210 | AS-BUILT DRAWINGS PER SPEC. NO. 01 11 00 | JOB | 10 | $0.00 | ||||
| 0211 | ENGINEERING RATE STRUCTURAL | HR | 20 | $0.00 | ||||
| 0212 | ENGINEERING RATE STRUCTURAL - FALL PROTECTION | JOB | 40 | $0.00 | ||||
| 0213 | MECHANICAL SUBCONTRACTOR | HR | 20 | $0.00 | ||||
| 0214 | ELECTRICAL SUBCONTRACTOR | HR | 20 | $0.00 | ||||
| 0215 | LABOR RATE - MISCELLANEOUS WORK | MH | 100 | $0.00 | ||||
| SPECIAL CONDITIONS AND CIRCUMSTANCES | ||||||||
| 0216 | HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOB | CSQ | 5 | $0.00 | ||||
| Subtotal | $0.00 | |||||||
| MODIFIERS | ||||||||
| 0217 | MULTIPLIER % TO BE ADDED TO TOTAL FOR GENERAL PROJECT REQUIREMENTS, i.e. MOBILIZATION/DEMOBILIZATION, EQUIPMENT RENTAL, ONSITE BATHROOM, SAFETY PROCEDURES, ETC. | % | $0.00 | |||||
| Subtotal | $0.00 | |||||||
| 0218 | MULTIPLIER % TO BE ADDED TO TOTAL FOR URGENT DELIVERY ORDER (UDO)-TEMPORARY DRY-IN WORK ONLY | % | $0.00 | |||||
| OPTION BASE YEAR TOTAL | $0.00 |
&"Arial,Bold"&10Page &P of &N &"Arial,Bold"&10&A - &F
YEAR THREE
| 7-Feb-17 | |
| ROOFING BID SCHEDULE | |
| IDIQ 2017-2022 | |
| Project No. FTFA 16-7000 Spec. No. 16AD | |
| 0.00 |
| BASIC YEAR | Contractor | |||||||
| LINE ITEM | SPEC | DESCRIPTION | Unit | EST. QTY. | UNIT PRICE | EST. TOTAL PRICE | UNIT PRICE | EST. TOTAL PRICE |
| 02 41 00 | DIVISION2-SELECTIVE DEMOLITION | |||||||
| 3001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK | LF | 1000 | $0.00 | ||||
| 3002 | REMOVE AND REPLACE WOOD DECKING | SF | 500 | $0.00 | ||||
| 3003 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING | SF | 2000 | $0.00 | ||||
| 3004 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 2" THICK | LF | 1000 | $0.00 | ||||
| 3005 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | SF | 500 | $0.00 | ||||
| 02 41 00 | DIVISION 2-TEAR-OFFS | |||||||
| 3006 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES NOT INCLUDE INSULATION) | SQ | 2000 | $0.00 | ||||
| 3007 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 2" THICK | SQ | 2000 | $0.00 | ||||
| 3008 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION OVER 2" THICK | BF | 1000 | $0.00 | ||||
| 3009 | REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | $0.00 | ||||
| 3010 | REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | $0.00 | ||||
| 3011 | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 200 | $0.00 | ||||
| 3012 | DEMOLITION, HAULING, AND DISPOSAL OF AGGREGATE BALLAST. INCLUDE SPUDDING BACK AND VACUUMING LOOSE AGGREGATE FROM ENTIRE ROOF SURFACE. | SQ | 200 | $0.00 | ||||
| 3013 | REMOVE SINGLE PLY ROOFING (INCLUDING PVC, EPDM, PIB, TPO AND OTHER MEMBRANE ROOFING) DOWN TO THE DECK. INCLUDE MEMBRANE, PENETRATION & WALL FLASHINGS AND MEMBRANE FASTENERS. NOT TO INCLUDE INSULATION, CRICKETS AND INSULATION FASTENERS. | SQ | 200 | $0.00 | ||||
| DIVISION 2-ASBESTOS ABATEMENT/ LEAD CONTROLS | ||||||||
| 3014 | 02 82 14 | CLASS I AND/OR CLASS II ASBESTOS CONTAINING ROOF MATERIALS (ACRM) ROOF MEMBRANE. | SF | 500 | $0.00 | |||
| 3015 | 02 82 16 | CEMENTITIOUS ASBESTOS FIBER ROOF DECK/FORM BOARD | SF | 100 | $0.00 | |||
| 3016 | 02 83 13 | LEAD CONTROLS | SF | 100 | $0.00 | |||
| 04 01 20 | DIVISION 4-MASONRY | |||||||
| 3016 | WATER BLAST CLEAN EXISTING MASONRY SURFACE IN ACCOURDANCE WITH PAINT MANUFACTURER'S RECOMMENDATIONS. | SF | 500 | $0.00 | ||||
| 3017 | CONCRETE MASONRY UNITS TO INCLUDE GROUTING, TUCK POINTING, FORMWORK, AND SUPPORTS. PERFORM WORK IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. | SF | 200 | $0.00 | ||||
| 05 30 00 | DIVISION 5-STEEL ROOF DECK | |||||||
| 3018 | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 100 | $0.00 | ||||
| DIVISION 5-METALS | ||||||||
| 05 40 00 | COLD-FORMED METAL FRAMING | |||||||
| 3019 | COLD-FORMED METAL FRAMING MEMBERS OR SOFFIT FRAMING, TO INCLUDE SADDLES, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND NAILERS ATTACHED AT THE TOPS OF CONCRETE OR MASONRY CURBS, EXPANSION JOINTS AND ROOF EDGES. FRAMING MEMBERS ARE 4" TO 8" WIDE BY 18 GAUGE OR THINNER. | LF | 1000 | $0.00 | ||||
| 3020 | RETROFIT SUB-PURLIN AND/OR FORMED SHAPED FRAMING SYSTEM MECHANICALLY FASTENED TO EXISTING AND/OR SUBSTRATE IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS. MINIMUM 16 GAUGE THICKNESS | LF | 1000 | $0.00 | ||||
| 05 50 13 | METAL FABRICATION | |||||||
| 3021 | SHOP PRIMED STEEL MATERIALS INCLUDING BUT NOT LIMITED TO: PLATES, ANGLES, ANCHOR BOLTS, STEEL PIPE SLEEVES, WEDGE TYPE INSERTS, EXPANSION ANCHORS, FRAMING, SUPPORTS AND FABRICATED ITEMS FOR APPLICATIONS THAT ARE NOT SPECIFIED IN OTHER SPECIFICATION SECTIONS. | LB | 500 | $0.00 | ||||
| 05 51 00, 05 51 33 | STAIRS AND LADDERS | |||||||
| FABRICATE AND INSTALL ALUMINUM ROOF ACCESS STAIRS OR LADDERS | LB | 100 | $0.00 | |||||
| FABRICATE AND INSTALL GALVANIZED STEEL ROOF ACCESS STAIRS OR LADDERS | LB | 100 | $0.00 | |||||
| REMOVE AND DISPOSE OF EXISTING ACCESS STAIRS OR LADDERS | LB | 100 | $0.00 | |||||
| 05 52 00 | PIPE AND TUBE RAILINGS | |||||||
| 3022 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT ALUMINUM PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 200 | $0.00 | ||||
| 3023 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT GALVANIZED STEEL PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 200 | $0.00 | ||||
| 3024 | REMOVE AND DISPOSE OF PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 200 | $0.00 | ||||
| 06 10 00 | DIVISION 6-ROUGH CARPENTRY | |||||||
| 3025 | FURNISH AND INSTALL PRESERVATIVE TREATED WOOD ROOF NAILERS, WHICH INCLUDES WOOD SADDLES OR CRICKETS, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND WOOD NAILERS BOLTED TO TOPS OF CONCRETE OR MASONRY CURBS AND AT EXPANSION JOINTS | BF | 500 | $0.00 | ||||
| 3026 | REMOVE AND REPLACE 3/8", 5/8"OR 3/4" ROOF SHEATHING OR SOFFIT ON RESIDENTIAL UNITS | SF | 200 | $0.00 | ||||
| 3027 | REMOVE AND REPLACE ROOF DECKING FOR RESIDENTIAL UNITS, WHICH INCLUDES 1x OR 2x DECKING | SF | 200 | $0.00 | ||||
| 3028 | FURNISH AND INSTALL ROOFING LUMBER FOR RESIDENTIAL UNITS, WHICH INCLUDES RAFTERS, STUDS, PLATES, CAPS, COLLAR BEAMS, SLEEPERS, NAILING STRIPS, SILLS, HEADERS AND FASCIA | BF | 200 | $0.00 | ||||
| 07 22 00 | DIVISION 7-INSULATION | |||||||
| POLYISOCYANURATE BOARD INSULATION | ||||||||
| 3029 | 1" THICK, R5.7 | SQ | 200 | $0.00 | ||||
| 3030 | 1.5" THICK R8.6 | SQ | 100 | $0.00 | ||||
| 3031 | 2" THICK, R11.4 | SQ | 200 | $0.00 | ||||
| 3032 | 3" THICK, R17.1 | SQ | 200 | $0.00 | ||||
| 3033 | 4" THICK, R22.8 | SQ | 100 | $0.00 | ||||
| 3034 | 5" THICK, R28.5 | SQ | 1,000 | $0.00 | ||||
| 3035 | 5.5" THICK, R31.3 | SQ | 200 | $0.00 | ||||
| 3036 | TAPERED FILL INSULATION BOARD FOR DRAINAGE | BF | 75,000 | $0.00 | ||||
| 07 22 00 | PROTECTION BOARDS: | |||||||
| 3037 | GLASS MAT GYPSUM ROOF BOARD | SQ | 500 | $0.00 | ||||
| 3038 | HIGH DENSITY WOOD FIBER BOARD | SQ | 500 | $0.00 | ||||
| 3039 | FIBER CANTS | LF | 1,000 | $0.00 | ||||
| 3040 | WOOD CANTS | LF | 1,000 | $0.00 | ||||
| 3041 | SHEATING PAPER FOR WOOD DECKS | SQ | 50 | $0.00 |