Atch_2_DBEH_12-2713_Repair_Lift_Stations_ITL_100__Drawings.pdf
PDF 11 MB Posted
- Attached to
- Repair Lift Stations, Various, CCAFS
- Solicitation number
- FA2521-17-B-0006
About this file
IFB # FA2521-17-B-0006 Attachment 2 Design Drawings for DBEH 12-2713 Repair Lift Stations Various 21 pages, dated 13 Jun 17
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
K
I
D
T
R
I
P
PERMIT(S)/ENVIRONMENTAL ACTIONS
REQUIRED PRIOR TO CONSTRUCTION
ERP/STORMWATER
ERP/WETLANDS/DREDGE & FILL
FDEP/DRINKING WATER
FDEP/DOM. WASTE WATER ARCHEO./HISTORICAL
SURVEY/WILDLIFE
OTHER
NONE
FDEP/IND. WASTE WATER
IRP
FDEP/FUEL TANK
NOI/SWPPP
ASBESTOS
NOTE: IF IT IS SUSPECTED THAT ANY HAZARDOUS MATERIAL NOT
IDENTIFIED ON THESE DRAWINGS IS REQUIRED TO BE DISTURBED IN
ORDER TO PERFORM THE CONTRACT WORK, LEAVE MATERIAL
UNDISTURBED AND IMMEDIATELY INFORM THE CONTRACTING OFFICER.
HEAVY METALS
YES NO
LEAD
OTHER
NOT
VERIFIED
HAZARDOUS MATERIALS
LS 70448
SCALE:
LOCATION MAP
NONE
TRUE
NORTH
N
A
T
L
A
N
T
C
O
E
A
N
B
A
N
A
N
A
R
V
E
R
CX 37
INDUSTRIAL
AREA
LEGEND: BOLD NOTES NEW ITEMS
EXISTING ABANDON WATER
EXISTING FIRE WATER
EXISTING POTABLE WATER
EXISTING UG ELECTRIC
EXISTING AERIAL ELECTRIC
EXISTING COMMUNICATION
EXISTING SANITARY SEWER
EXISTING NATURAL GAS
EXISTING STORM DRAIN
PROPOSED SANITARY SEWER FORCE MAIN
E E
E-OH
C C
SS
NG
SD
FM
W W
FW
AB/W
BENCHMARK LOCATION
EXISTING POST-INDICATOR VALVE
EXISTING VALVE
EXISTING BACKFLOW PREVENTION
EXISTING FIRE HYDRANT
EXISTING COMMUNICATI0NS MANHOLE
EXISTING ELECTRIC MANHOLE
EXISTING ELEVATION
PROPOSED ELEVATION
X.X
X.XX
DBEH 12-2713
REPAIR LIFT STATIONS - ITL
CAPE CANAVERAL AIR FORCE STATION
CAPE CANAVERAL, FLORIDA
ITL AREA
LS 70453
LS 54720
LOCC
LS 27213
L
IG
H T
H O
U S
E R
D
LS 78170
LS 44407
P
H
I L
L
I P
R
K
W
A
Y
PROPOSED SILT FENCE
SF
PROPOSED WATER W W
EXISTING SANITARY SEWER FORCE MAIN FM
SQ. SQUARE
NDT LB266
CLF CHAIN LINK FENCE
CO CLEANOUT
CHW CONCRETE HEADWALL
COS
CPP
CHANGE OF SLOPE
CONCRETE POWER POLE
ESP
ET
FLS
GA
GRHH
HB
LS
ELECTRIC SERVICE PANEL
ELECTRIC TRANSFORMER
FLOWLINE SWALE
GUY ANCHOR
GROUND HANDHOLE
HOSE BIB
LIFT STATION
MHR METAL HANDRAIL
MMH
MPH
MTL.
MISCELLANEOUS MANHOLE
MILES PER HOUR
METAL
MONITORING WELL
PAL
PVC
RCP
SLS
SMH
TRAVERSE NAIL & DISK STAMPED "TRAVERSE LB 266"
PALM TREE + TRUNK DIAMETER IN INCHES
POLYVINYL CHLORIDE PIPE
REINFORCED CONCRETE PIPE
SPEED LIMIT SIGN
SANITARY MANHOLE
TOB
TOS
TSMH
TOP OF BANK
TOE OF SLOPE
TRAFFIC SIGNAL MANHOLE
WLP
WP
WPP
WV
WOOD LIGHT POLE
WOOD POST
WOOD POWER POLE
WATER VALVE
MP METAL POST
SSx SANITARY SEWER PIPE
T.O.P. TOP OF PIPE ELEVATION
HDPE HIGH DENSITY POLYETHLENE PIPE
FM FORCEMAIN
MW
ABBREVIATIONS:
Sheet List Table
Sheet Number Sheet Title REV
GENERAL
G-001
LOCATION MAP, DRAWING INDEX AND NOTES
CIVIL
C-101 ITL LS 70533 & 70453 DEMO AND ITL LS 70448 NEW - SITE PLAN
C-102 HANGAR NTU LIFT STATION 54720 DEMO & NEW - SITE PLAN
C-103 PHOTO OPS LS 44407 DEMO & LS 44406 NEW - SITE PLAN
C-104 LOCC LIFT STATION 27213 DEMO & LS 27214 NEW - SITE PLAN
C-105 REPUMP LIFT STATION 78170 DEMO AND NEW - SITE PLAN
C-501 LOCC AND PHOTO OPS LIFT STATION DETAILS
C-502 ITL LIFT STATION TRI-PUMP DETAILS
C-503 SANITARY SEWER DETAILS SHEET 1
C-504 SANITARY SEWER DETAILS SHEET 2
C-505 MISCELLANEOUS DETAILS
ELECTRICAL
E-001
ELECTRICAL NOTES, ABBREVIATIONS AND LEGEND
E-101 ITL LIFT STATION 70533 & 70453 ELECTRICAL DEMOLITION PLAN
E-102 ITL LIFT STATION 70448 ELECTRICAL SITE PLAN AND DETAIL - NEW
E-103 PHOTO OPS LS 44407 DEMO & LS 44406 NEW - ELECTRICAL PLAN
E-104 LOCC LS 27213 DEMO & LS 27214 NEW - ELECTRICAL PLAN
E-501 ELECTRICAL DETAILS
E-601 LIFT STATION SEQUENCE OF OPERATIONS AND CONTROL PANEL
E-602 LIFT STATION CONTROL PANEL DIAGRAM
E-603 LIFT STATION CONTROL PANEL AND WIRING DIAGRAM
E-604
SINGLE-LINE DIAGRAMS - EXISTING, DEMO AND NEW
GENERAL NOTES:
1. IF AT ALL POSSIBLE, ALL DEMOLITION WORK SHALL OCCUR AFTER THE NEW SEWER LIFT STATION
SYSTEM IS PLACED INTO OPERATION TO AVOID UNNECESSARY SEWER OUTAGE.
2. NEW ELECTRICAL SUPPLY AND CONTROL PANEL SHALL BE INSTALLED AND OPERATIONAL IN ORDER TO
MINIMIZE POWER OUTAGE DURING TRANSFER.
3. COORDINATE ALL UTILITY OUTAGES THROUGH THE CONTRACTING OFFICER. THE CONTRACTOR SHALL
SUBMIT A PLAN AND BE RESPONSIBLE FOR TEMPORARY PUMP STATION SEWAGE BYPASS AT EACH LIFT
STATION TO SUPPORT THE UTILITY TIE-IN CONNECTIONS AND TRANSFER SERVICE TO THE NEW LIFT
STATION. REQUESTING A UTILITY OUTAGE WITHOUT ALTERNATIVE MEANS TO PROVIDE SEWAGE
COLLECTION IS NOT ACCEPTABLE.
4. CONTRACTOR IS RESPONSIBLE TO REQUEST UTILITY LOCATES AND OBTAIN A CCAFS DIG PERMIT AF
FORM 103 PRIOR TO CONSTRUCTION.
5. UNDERGROUND UTILITY LINES SHOWN WERE NOT LOCATED BY FIELD SURVEY, BUT ARE PROVIDED BY
GOV'T FOR INFORMATIONAL PURPOSES ONLY.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING CONCRETE FOR ASBESTOS PER SPECIFICATION
PRIOR TO CUTTING OPERATIONS FOR DISPOSAL OF STRUCTURES SHOWN TO BE REMOVED OR
DEMOLISHED.
7. CONTRACTOR SHALL COORDINATE WITH 45 CEIE PRIOR TO CONSTRUCTION ACTIVITIES FOR A GOPHER
TORTOISE SURVEY.
8. A REQUEST FOR FDEP PERMIT CLEARANCE MUST BE APPROVED PRIOR TO PLACING NEW ITL AREA LIFT
STATIONS 70448, 44406 AND 27214 INTO OPERATION.
9. DURING DEMOLITION OF THE EXISTING LIFT STATIONS, THE EXISTING PUMPS, CONTROL PANEL, AND
ELECTRICAL EQUIPMENT AND ACCESSORIES THAT ARE TO BE REMOVED BELONG TO THE BASE
OPERATIONS SUPPORT CONTRACTOR FOR FIRST RIGHT OF REFUSAL TO KEEP AS SPARE PARTS; THE
CONTRACTOR SHALL COORDINATE THESE ITEMS WITH THE BASE OPERATIONS SUPPORT CONTRACTOR.
LS 70533
C-101: ITL
C-102:
HGR N,T,U
LS 44406
C-103:
PHOTO OPS
C-104:
LOCC
LS 27214
C-105:
REPUMP
A
B
2 3
C
D
1 2 3
4 5 6
B
U I L
T
E
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
SHEET
IDENTIFICATION
C
D
A
B
U S
F
T
H
C
I V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
C O
N T
R A
F
A D
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S n g i n e e r i n g I n c
L L
E N
E A
D E
L I V
E R
Y
N
O
F A
D
An O ne id a N at io n Co m pa ny
G-001
M
S
P I V
E Y
M
S
P I V
E Y
L O
C A
T I O
N
M
A P
D
R A
W I N
G
I N
D E
X
A N
D
N
O T
E S
C
H
A R
T N
E T
T
D B
E H
G
B
E A
R D
R E
P A
F
T
S
T A
T I O
T
L
D B
C C
A F
S
F
L
FRP FIBERGLASS REINFORCEMENT POLYESTER
BASE OPERATIONS:
COMMUNICATIONS:
PROJECT MANAGER:
CHIEF, ENGINEERING FLIGHT:
USER:
SAFETY:
SECURITY FORCES:
ATO:
OTHER:
ENVIRONMENTAL:
FIRE:
A
P
P
R
O
V
E
D
A
M b a r v i r
AutoCAD SHX Text C
AutoCAD SHX Text x
X
S S x
S S x
S S x
S S x
S S x
S S x
S S x
F
M
F
M
F
M
F
M
F
M
F
M
F M
F M
F M
F
W
F W
F W
F W
F W
F W
F W
F
W
FM
FM
FM
FM
FM
FM
FM
FM
S F
S F
S F
SF SF SF SF SF
S
F
S
F
S
F
S
F
S F
S F
FM
FM
FM
FM
FM
FM
FM
FM
S
F
SF
SF
SF
X
X
M
F
F
E x
E x
E x
E x
E x
E x
E x
E x
E x
S
S x
S S x
S S x
S S x
S S x
S S x
S S x
S S x
F
W
F W
F W
F W
F W
F W
F W
F
W
FM
FM
FM
FM
F M
F M
F M
F M
F M
FM
FM
FM
FM
F M
F M
F M
F M
F M
F M
S
S
MF
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
A
I P
E E
E
W W
W W
SCALE:
SITE DEMOLITION PLAN
1" = 10'
LIFT STATIONS 70533 & 70453
TRUE
NORTH
N
SCALE:
SITE CONSTRUCTION PLAN
1" = 10'
NEW LIFT STATION #70448
TRUE
NORTH
N
DEMOLITION FLAG NOTES: CONSTRUCTION FLAG NOTES:
PUMP SELECTION:
NEW LIFT STATION #70448
HYDROMATIC S4KX, 500 GPM @ 110' TDH
10.875" DIA. IMPELLER
1750 RPM, 480V/3ph/60Hz - 30 HP SOFT START MOTOR
DESIGN CONDITIONS:
EXISTING LIFT STATION #70453*
140 GPM @ 15' TDH
EXISTING LIFT STATION #70533*
424 GPM @ 78.5' TDH
NEW LS #70448 PRIMARY OPERATING CONDITIONS*
DESIGN POINT:
*CALCULATED SYSTEM TOTAL DYNAMIC HEAD, CONTRACTOR
SHALL PERFORM A FIELD PUMP TEST TO VERIFY TDH AND
COORDINATE WITH BASE OPERATIONS SUPPORT CONTRACTOR
PRIOR TO ORDERING PUMPS.
LIFT STATION ELEVATIONS:
TOP OF STATION = Elev. - 8.60
INFLUENT 6" FM INVERT = Elev. - 2.13
INFLUENT 8" SS INVERT = Elev. - (-)1.70
HIGH WATER ALARM = Elev. - (-)2.10
LAG PUMP ON = Elev. - (-)2.60
LEAD PUMP ON = Elev. - (-)3.10
PUMPS OFF = Elev. - (-)4.40
SUMP INVERT = Elev. - (-)7.40
6" PVC
SCALE:
LIFT STATION 70453
NONE SCALE:
LIFT STATION 70533
NONE
V
C
V
C
V C
1. PROVIDE, INSTALL AND MAINTAIN SILT FENCE (APPROX. LOCATION); REMOVE UPON PROJECT COMPLETION.
2. PORTION OF EXISTING SANITARY SEWER FORCE MAIN OR GRAVITY MAIN TO REMAIN.
3. CUT AND REMOVE PORTION OF SEWER FORCE MAIN PIPE.
4. ONCE NEW LIFT STATION IS OPERATIONAL, DEMOLISH, REMOVE, AND DISPOSE OF DEBRIS FROM LIFT STATION
70533 AND 70453, REMOVE SUMP WALLS TO 2' BELOW GRADE, BREAK OUT BOTTOM OF SUMPS, FILL SUMPS TO
GRADE W/ CLEAN FILL.
5. EXISTING WET WELL ACCESS, VALVE VAULT AND CONCRETE SLABS TO BE DEMOLISHED AND DISPOSE OF DEBRIS.
6. OPEN CUT PAVEMENT REMOVAL AND RESTORATION FOR SANITARY FORCE MAIN INSTALLATION. CONTRACTOR
SHALL RESTORE ALL DISTURBED IMPROVEMENTS TO MATCH ORIGINAL CONDITIONS.
6. PROVIDE TRIPLEX LIFT STATION, 10' INNER DIA. WET WELL, (3) IN-SERVICE NON-CLOG EXPLOSION PROOF
SUBMERSIBLE PUMPS, PERIMETER CONCRETE PAD TOP ELEV. 8.60', FORCE MAIN PIPING, ABOVE GROUND
VALVES, AND MOTOR CONTROL CENTER. SEE SHEET C-502.
7. PROVIDE SANITARY MANHOLE W/ INTEGRAL FLANGED BOTTOM BARREL, WITH INTERIOR SPECIALTY LINER. RIM
ELEV 8.00', S. INV. (-)1.51 N INV. (-)1.60; CONTRACTOR SHALL VERIFY ELEVATION OF EXISTING SEWER PRIOR TO
ORDERING MANHOLE. SEE SHEET C-503.
8. CONSTRUCT 24 LF - 8" C900 DR18 GRAVITY SEWER FROM NEW MANHOLE TO NEW WET WELL, MIN. SLOPE 0.4%, UPSTREAM (MH) INV ELEV. (-)1.60, DOWNSTREAM (WW) INV ELEV. (-)1.70'.
9. CONSTRUCT 121 LF OF 6" INFLUENT FORCE MAIN USING RESTRAINED 90° BEND CONNECTION, AND 95 LF OF 6"
DISCHARGE FORCE MAIN TO CONNECT FROM EXISTING 6" FORCE MAINS TO NEW L.S. 70448 PROVIDE MIN. 30"
COVER AND CROSS UNDER THE EXISTING WATER MAIN WITH 12" MIN. CLEARANCE BELOW. PROVIDE OPEN CUT
ASPHALT RESTORATION.
10. CONSTRUCT RESTRAINED (2) 8"x45° MJ FITTINGS.
11. ABOVE GRADE 6" FL PLUG VALVE WITH (2) 6"x45° BENDS TO TRANSITION BELOW GRADE. 8"X6"
12. PROVIDE SOD RESTORATION FOR ALL DISTURBED AREAS, TYP. IN ACCORDANCE WITH SPECIFICATIONS.
13. PIPE BOLLARD (TYP) AT (4) CORNERS. INSTALL WITHIN FOOTPRINT OF TOP SLAB 10" CLEAR FROM EDGE.
14. PROVIDE CLEAN FILL AROUND LIFT STATION SITE TO BRING AREA UP TO GRADE, SLOPE MAX. 1:4 FROM CONTOUR
EL. 8 DOWN TO MATCH EXISTING GRADE, GRADING SHALL TIE-IN TO EXISTING SLOPE.
15. PROVIDE 2" SCH 80 PVC WASH DOWN WATER SERVICE WITH 2"X1" REDUCER AND 1" BACK FLOW PREVENTER AND
HOSE BIBB CONNECTION IN CONCRETE STAND AT LIFT STATION. PROVIDE WET TAP TO EXISTING 8" DUCTILE IRON
150 PSI. FIRE LINE W/ 2" 200 PSI ZURN WILKINS PRESSURE CONTROL VALVE OR APPROVED EQUAL.
6" PVC
L
C-505
6" PVC
8" PVC
LS 70533
LS 70453
4 5
L
C-505
S
G
C-503
M
C-505
N
C-505
14 12
T
I T
I
R
O
A
D
ASPHALT
RESTORATION
TOP = 8.60
6'
18'
29'
33'
ASPHALT
ASPHALT
4 PLACES
24 L.F.
A
B
2 3
C
D
1 2 3
4 5 6
I
T
E
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
SHEET
IDENTIFICATION
C
D
A
B
U S
T
H
C
I V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
C O
N T
R A
F
A D
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S n g i n e e r i n g I n c
L L
E N
E A
D E
L I V
E R
Y
N
O
F A
D
An O ne id a N at io n Co m pa ny
C-101
M
S
P I V
E Y
M
S
P I V
E Y
I T
L
D
E M
O
A
N D
I T
L
N
W
I T
E
P
L A
N
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
F
T
S
T A
T I O
T
L
D B
C C
A F
S
F
L
P
V C
P
V C
G
C-503
EXISTING
ELECTRICAL
PANEL "P"
EXISTING
ELECTRICAL
PANEL "P"
SEE WATER SERVICE
DETAIL BELOW FOR
CONTINUATION
LS 70448
T
I T
I
R
O
A
D
150 GPM @ 32' TDH
300 GPM @ 57' TDH
500 GPM @ 110' TDH
750 GPM @ 207' TDH
30'10' 20'0'
10'
GRAPHIC SCALE 1" = 10'
8" D
.I.
A
M b a r v i r
AutoCAD SHX Text
90° FL BEND
PIPE STAND
(TYP.)
INSTALL 2" WELDED STAINLESS STEEL
NIPPLE OR 2" DOUBLE STRAP SADDLE W/
2" 316 S.S. BALL VALVE & 2" S.S. PLUG
12" FL SPOOL
90° FL BEND
FL CHECK VALVE (LEVER & WEIGHT)
SEAT END ON CHECK
VALVE SIDE
FLANGED SPOOL PIECE OR FLANGED
FILLER AS NEEDED. SEE PUMP
SEPARATION NOTES.
SEAT END OF PLUG VALVE
90° BEND (FLANGED)
PLUG VALVE (FLANGED)
12" LONG (MIN)
FLANGE SPOOL PIECE
PUMPOUT MALE 3" CAMLOCK (PO)
w/CAP (ALUM)
BLIND FLANGE w/NIPPLE (S.S.)
REDUCER (FLANGED) IF REQUIRED
SEAT END ON CHECK VALVE SIDE
TEE (FLANGED) TYP.
PLUG VALVE (FLANGED)
FLANGED CHECK VALVE
(LEVER & WEIGHT)
TO 6"x45° MJ BEND AND
6" PVC SCH 80 EFFLUENT PIPE
(BELOW GROUND)
(2) FL TEE (NOT SHOWN)
6" FExMJ SCH 80
PVC PIPE
PLUG VALVE (FLANGED)
45° MJ BEND
6" EFFLUENT FM PIPE
316 S.S.
RESTRAINT
RODS
SEAT END OF PLUG VALVE
6x6-W 2.9x2.9 W.W.F.
OR FIBERMESH
3000 PSI CONCRETE
FL PLUG VALVE W/ 2-INCH NUT
OPERATOR AND GEAR ACTUATOR
PIPE STAND
(TYP.)
45° FL BEND
45° FL BEND DOWN
1" CHAMFER EDGES (TYP.)
FINISHED
GRADE
9.55
AIR RELEASE VALVE W/
1-1/2" SCH 80 PVC DRAIN
ATTACH 1-1/2" SCH. 80 PVC
W/CONDUIT HANGERS FROM
FROM FLANGE BOLTS
FL PLUG VALVE W/2-INCH OPERATOR
NUT AND GEAR ACTUATOR
E
C
P
F
M
F
M
C
C
C
E x
E x
E x
E x
W
W
W
W
S
S
S
S
S
S
F
M
F
M
F
M
F
M
F
M
F
M
F
M
S
S
F
M
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
F
M
F
M
S
S
F
M
F
M
F
M
F
M
F
M
M
F
S
F
S
F
S
F
S
F
S
F
S
F
S
F
S
F
E
C
P
C
C
C
E x
E x
E x
E x
E
W
W
W
W
S
S
S
S
S
S
F
M
F
M
F
M
F
M
F
M
F
M
F
M
S
SF
M
F
M
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
F
M
F
M
S
S
F
M
F
M
F
M
F
M
F
M
M
F
S
F
S
F
S
F
S
F
S
F
S
F
S
F
S
F
F
M
SCALE:
DEMOLITION SITE PLAN
1" = 5'
HANGAR N,T,U LIFT STATION 54720
TRUE
NORTH
N
SCALE:
NEW CONSTRUCTION SITE PLAN
1" = 5'
HANGAR N,T,U LIFT STATION 54720
TRUE
NORTH
N
DEMOLITION FLAG NOTES: CONSTRUCTION FLAG NOTES:
1. PROVIDE, INSTALL AND MAINTAIN SILT FENCE (APPROX. LOCATION);
REMOVE UPON PROJECT COMPLETION.
2. PORTION OF EXISTING SANITARY FORCE MAIN TO REMAIN.
3. CUT AND REMOVE PORTION OF FORCE MAIN PIPE, VALVES, FITTINGS, FROM
INSIDE VAULT TO JUST OUTSIDE OF THE WET WELL. DEMO ABOVE GROUND
EMERGENCY PUMP OUT CONNECTION.
4. REMOVE EXISTING CONCRETE VAULT METAL LIDS, AND REMOVE CONCRETE
BOX TOP RIM SECTION.
5. REMOVE EXISTING WET WELL PIPING.
6. EXISTING ELECTRICAL PANEL. METER AND DISCONNECT TO REMAIN.
7. PROVIDE 6" TAPPING SLEEVE AND 6" TAPPING VALVE FOR TEMPORARY BYPASS PUMPING,
CLOSE AND PLUG VALVE WHEN NEW DISCHARGE PIPING IS OPERATIONAL.
8. DURING NEW DISCHARGE PIPE TIE-IN CONSTRUCTION, PROVIDE TEMPORARY BYPASS
PUMPING FOR STATION FLOW: REMOVE 90° FL BEND INSIDE WET WELL, CONNECT
TEMPORARY BYPASS PIPING TO SINGLE PUMP, TURN SECOND PUMP OFF, RESTRAIN
TEMPORARY PIPING OR ANCHOR TO GROUND TO PREVENT MOVEMENT, CONNECT TO
EXISTING 10" FM WITH 10"x8" TAPPING SLEEVE, 8" TAPPING VALVE AND 10"x8" REDUCER.
ONCE NEW PIPING IS READY TO BECOME OPERATIONAL, REMOVE TEMPORARY PIPING,
CLOSE AND PLUG 8" VALVE, REINSTALL 90° FL BEND INSIDE WET WELL, RESTORE
OPERATION OF BOTH PUMPS. ALTERNATIVELY, THE CONTRACTOR MAY PROVIDE A
DIFFERENT PUMP BYPASS PLAN TO THE CONTRACTING OFFICER FOR APPROVAL.
9. RESTRAINED 90° MJ BENDS CONNECTED TO EXISTING 6" DISCHARGE PIPE JUST OUTSIDE
OF WET WELL WALL, VERTICAL 6" C-900 PVC (MJxFE), AND ABOVE GRADE VALVE
ASSEMBLY AS SHOWN IN DETAIL A AND B, THIS SHEET.
10. PIPE BOLLARD (4) (TYP) AT FOUR CORNERS, INSTALL WITHIN FOOTPRINT OF CONCRETE
SLAB, 10" FROM EDGE OF PAD.
11. ABOVE GROUND 6" FL PLUG VALVE AND 90° FL BEND TO 6" FL C-900 PVC THROUGH NEW
CONCRETE TOP SLAB, SEAL OPENING WITH LINK-SEAL. AIR RELEASE VALVE WITH
SCHEDULE 80 PVC DRAIN TO WET WELL SEE DETAIL THIS SHEET.
12. PROVIDE SOD RESTORATION FOR ALL DISTURBED AREAS, TYP IN ACCORDANCE WITH
SPECIFICATIONS.
13. CONNECT TO EXISTING 6" FORCE MAIN WITH 6" MJ. 45° BEND.
SCALE:
LIFT STATION 54720
NONE
SCALE:
PIPE ASSEMBLY DETAIL
NONE
SCALE:
CONC. PAD DETAIL
NONE
30"
5'
T
O
C
O V
E R
1'
EXISTING
WET WELL
NEW 6" PIPING
SCH 80 PVC
L
C-505
N
C-505
CONC. PAD
CONC. PAD
EXISTING
FORCE MAIN
K
C-504
J
C-504
81 L.F.
321 SQ.FT.
A
B
2 3
C
D
1 2 3
4 5 6
I
T
E
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
SHEET
IDENTIFICATION
C
D
A
B
U S
T
H
C
I V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
C O
N T
R A
F
A D
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S n g i n e e r i n g I n c
L L
E N
E A
D E
L I V
E R
Y
N
O
F A
D
An O ne id a N at io n Co m pa ny
C-102
M
S
P I V
E Y
M
S
P I V
E Y
H A
N G
F
T
S
T A
T I O
N
D E
M
I T
E
P
L A
N
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
F
T
S
T A
T I O
T
L
D B
C C
A F
S
F
L
10' 15'0'
5'
5'
GRAPHIC SCALE 1" = 5'
6 6
A
M b a r v i r
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
W
W
S
S
S
S
A
I P
A I P
A I P
A I P
A
IP
A I P
A I P
S
S
S
S
F M
F M
S
F
S F
S F
S F
S F
S F
S F
S
F
E x
E x
E x
E x
E x
F
S
S
S
S
E
E
E
W
W
W
W
A
I
P
A
I
P
A
I
P
A
I
P
A
I
P
E
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
W
W
A
I
P
S
S
S
S
S
S
S
S
F M
F M
F M
F M
F M
F M
F M
F M
S
F
S F
S F
S F
S F
S F
S F
S
F
F
E x
E x
E x
E x
E x
S S
S S
S S
S S
S S
S
S
S S
S S
S
S
E x
E x
E x
E x
SCALE:
DEMOLITION SITE PLAN
1" = 10'
PHOTO OPS LS 44407
TRUE
NORTH
N
SCALE:
NEW CONSTRUCTION SITE PLAN
1" = 10'
PHOTO OPS LS 44406
TRUE
NORTH
N
DEMOLITION FLAG NOTES:
1. PROVIDE, INSTALL AND MAINTAIN SILT FENCE (APPROX. LOCATION); REMOVE UPON PROJECT COMPLETION.
2. PORTION OF EXISTING SANITARY SEWER MAIN TO REMAIN.
3. CUT AND ABANDON IN PLACE PORTION OF GRAVITY SEWER PIPE.
4. CUT AND REMOVE PORTION OF SEWER FORCE MAIN PIPE.
5. ONCE NEW LIFT STATION IS OPERATIONAL, DEMOLISH, REMOVE, AND DISPOSE OF DEBRIS FROM LIFT STATION 44407, REMOVE SUMP WALLS TO 2' BELOW GRADE, BREAK OUT BOTTOM OF SUMPS, FILL SUMPS TO GRADE WITH CLEAN FILL.
6. OPEN CUT PAVEMENT REMOVAL AND RESTORATION FOR SANITARY SEWER PIPE INSTALLATION. CONTRACTOR SHALL
RESTORE ALL DISTURBED IMPROVEMENTS TO MATCH ORIGINAL CONDITIONS.
CONSTRUCTION FLAG NOTES:
SANITARY MH
TOP= 8.34
W INV. = 4.48
N INV.= 3.97
S. INV. = 3.95
LS 44407
METAL SHED
F.E.E. = 9.08
V
C
P
V
C
P
V
C
P
H
D
P
E
P
V
C
F A
C
F A
C
C
U
R
B
A
S
P
H
A
L T
G
R
A
S
S
7. PROVIDE DUPLEX LIFT STATION, 6' INNER DIA. WET WELL, (2) IN-SERVICE GRINDER EXPLOSION POOF SUBMERSIBLE PUMPS, PERIMETER CONCRETE PAD TOP ELEV. 9.00, FORCE MAIN PIPING, ABOVE GROUND VALVES, AND MOTOR CONTROL CENTER.
SEE SHEET C-501.
8. AFTER NEW LIFT STATION 44406 IS OPERATIONAL, CONNECT EXISTING 6" PVC W/ CLEAN OUT APPROX. INVERT ELEV. 5.40.
9. CONSTRUCT 6" C900 DR18 GRAVITY SEWER FROM SERVICE LINES TO NEW WET WELL, SLOPE 1.0%, UPSTREAM (MH) INV ELEV.
5.40, DOWNSTREAM (WW) INV ELEV. 5.00'.
10. CONSTRUCT 3" FORCE MAIN TO CONNECT FROM EXISTING 3" FORCE MAIN TO NEW LIFT STATION 44406 USING RESTRAINED
45° BEND CONNECTION, PROVIDE MIN. 30" COVER.
11. PROVIDE 2" WATER SERVICE SADDLE TAP WITH 2" GATE VALVE.
12. ABOVE GRADE 3" FL PLUG VALVE WITH (2) 3"x45° BENDS TO TRANSITION BELOW GRADE. SEE SHEET C-501.
13. PROVIDE SOD RESTORATION FOR ALL DISTURBED AREAS, TYP IN ACCORDANCE WITH SPECIFICATIONS.
14. PIPE BOLLARD (TYP) AT (4) CORNERS SHOWN ON PLAN, SEE DETAIL. INSTALL WITHIN FOOTPRINT OF TOP SLAB 10" CLEAR
FROM EDGE.
15. PROVIDE CLEAN FILL AROUND LIFT STATION SITE TO BRING AREA UP TO GRADE, SLOPE MAX. 1:4 FROM CONTOUR ELEV. 8.5
DOWN TO MATCH EXISTING GRADE, GRADING SHALL TIE-IN TO EXISTING SLOPE.
16. PROVIDE 2" WASH DOWN WATER SERVICE CONNECTION FROM EXISTING WATER LINE. PROVIDE 2"x1" REDUCER AND 1" BACK
FLOW PREVENTER W/ HOSE BIBB.
17. REPAIR OPEN CUT ASPHALT PAVEMENT TO MATCH ORIGINAL CONDITION.
MW
MW
EMH
MW
WPP
CPP
C
U
R
B
A
S
P
H
A
L T
G
R
A
S
S
G
N
D
MW
MW
EMH
MW
WPP
CPP
TOP = 9.00
SCALE:
LIFT STATION 44407
NONE
L
C-505
G
C-503
G
C-503
M
C-505
459 SQ. FT.
SEE SHEET E-103
N
C-505
4 PLACES
C.O.
A
B
2 3
C
D
1 2 3
4 5 6
I
T
E
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
SHEET
IDENTIFICATION
C
D
A
B
U S
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
C O
N T
R A
F
A
D
A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S n g i n e e r i n g I n c
L L
E N
E A
D E
L I V
E R
Y
N
O
F A
D
An O ne id a N at io n Co m pa ny
C-103
M
S
P I V
E Y
M
S
P I V
E Y
P H
O T
O
O
M
O
I T
E
P
L A
N
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
F
T
S
T A
T I O
T
L
D B
C C
A F
S
F
L
G
C-503
PUMP SELECTION:
NEW LIFT STATION #44406
HYDROMATIC HPGHX, 45 GPM @ 27' TDH
7.0" DIA. IMPELLER
1750 RPM, 3-HP 480V/3ph/60Hz
MOTOR RATED FOR 45 GPM @ 27' TDH
DESIGN CONDITIONS:
PRIMARY OPERATING CONDITIONS*
DESIGN POINT:
*CALCULATED SYSTEM TOTAL DYNAMIC HEAD,
CONTRACTOR SHALL PERFORM A FIELD PUMP
TEST TO VERIFY TDH AND COORDINATE WITH BASE
OPERATIONS SUPPORT CONTRACTOR PRIOR TO
ORDERING PUMPS.
LIFT STATION ELEVATIONS:
TOP OF STATION = Elev. - 9.00
INFLUENT 6" SS INVERT = Elev. - 5.00
HIGH WATER ALARM = Elev. - 4.50
LAG PUMP ON = Elev. - 4.00
LEAD PUMP ON = Elev. - 3.50
PUMPS OFF = Elev. - 3.00
SUMP INVERT = Elev. - 1.00
G
C-503
ASPHALT
RESTORATION
ASPHALT
RESTORATION
TO BE
ABANDONED
IN PLACE
ASPHALT
RESTORATION
ASPHALT
RESTORATION
15 GPM @ 12' TDH
30 GPM @ 18' TDH
45 GPM @ 27' TDH
60 GPM @ 38' TDH
30'10' 20'0'
10'
GRAPHIC SCALE 1" = 10'
A
M b a r v i r
AutoCAD SHX Text
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
F
W
F
W
F
W
F
W
F
W
F
W
F
W
F
M
F
M
F
M
F
M
S
F
S
F
S
S x
S
S x
E x
E x
E x
E x
F
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
F
W
F
W
F
W
F
W
F
W
F
W
F
W
F
M
F
M
F
M
F
M
S
F
S
F
S
S x
S
S x
F
E E E E
SCALE:
DEMOLITION SITE PLAN
1" = 10'
LOCC LIFT STATION 27213
DEMOLITION NOTES:
TRUE
NORTH
N
1. PROVIDE, INSTALL AND MAINTAIN SILT FENCE (APPROX. LOCATION); REMOVE UPON PROJECT COMPLETION.
2. PORTION OF EXISTING SANITARY SEWER MAIN TO REMAIN.
3. CUT AND REMOVE PORTION OF GRAVITY SEWER PIPE.
4. CUT AND REMOVE PORTION OF SEWER FORCE MAIN PIPE.
5. ONCE NEW LIFT STATION IS OPERATIONAL, DEMOLISH, REMOVE, AND DISPOSE OF DEBRIS FROM LIFT STATION
27213, REMOVE SUMP WALLS TO 2' BELOW GRADE, BREAK OUT BOTTOM OF SUMPS, FILL SUMPS TO GRADE W/
CLEAN FILL.
6. EXISTING WET WELL ACCESS, VALVE VAULT AND CONCRETE SLABS TO BE DEMOLISHED AND DISPOSE OF DEBRIS.
SCALE:
NEW CONSTRUCTION SITE PLAN
1" = 10'
LOCC LIFT STATION 27214
7. PROVIDE DUPLEX LIFT STATION, 6' INNER DIA. WET WELL, (2) IN-SERVICE GRINDER EXPLOSION PROOF
SUBMERSIBLE PUMPS, PERIMETER CONCRETE PAD TOP ELEV. 8.25, FORCE MAIN PIPING, ABOVE GROUND
VALVES, AND MOTOR CONTROL CENTER. SEE SHEET C-501.
8. PROVIDE SANITARY MANHOLE W/ INTEGRAL FLANGED BOTTOM BARREL, WITH INTERIOR SPECIALTY
LINER. RIM ELEV. 8.00, E INV 5.59; N INV 5.55, CONTRACTOR SHALL VERIFY ELEVATION OF EXISTING
SEWER PRIOR TO ORDERING MANHOLE. SEE SHEET C-503, MANHOLE DETAIL.
9. CONSTRUCT 8" C900 DR18 GRAVITY SEWER FROM NEW MANHOLE TO NEW WET WELL, MIN. SLOPE 0.4%, UPSTREAM (MH) INV ELEV. 5.55, DOWNSTREAM (WW) INV ELEV. 5.50.
10. CONSTRUCT 4" FORCE MAIN TO CONNECT FROM EXISTING 4" FORCE MAIN TO NEW L.S. 27214 USING
RESTRAINED 90° BEND CONNECTION, PROVIDE MIN. 30" COVER.
11. CONSTRUCT RESTRAINED 4"x90° MJ FITTING.
12. ABOVE GRADE 3" FL PLUG VALVE WITH (2) 3"x45° BENDS TO TRANSITION BELOW GRADE.
13. PROVIDE SOD RESTORATION FOR ALL DISTURBED AREAS, TYP. IN ACCORDANCE WITH SPECIFICATIONS.
14. PIPE BOLLARD (TYP.) AT (4) CORNERS, SEE DETAIL. INSTALL WITHIN FOOTPRINT OF TOP SLAB 10" CLEAR
FROM EDGE.
15. PROVIDE CLEAN FILL AROUND LIFT STATION SITE TO BRING AREA UP TO GRADE, SLOPE MAX. 1:4 FROM
CONTOUR ELEV. 7.75 DOWN TO MATCH EXISTING GRADE, GRADING SHALL TIE-IN TO EXISTING SLOPE.
16. PROVIDE 2" WASH DOWN WATER SERVICE WITH 2"x1" REDUCER AND 1" BACK FLOW PREVENTER AND
HOSE BIBB CONNECTION FROM EXISTING FIRE WATER LINE.
CONSTRUCTION NOTES:
SCALE:
LIFT STATION 27213
NONE
FAC 27212
FAC 27220
P
F
U
N
K
C
P
F
U
N
K
C
LIGHT
POLE
T
O
S
T
O
B
FAC 27212
FAC 27220
T
O
S
T
O
B
ASPHALT
ASPHALT
N
C-505
S
L
C-505
M
C-505
A
B
2 3
C
D
1 2 3
4 5 6
I
T
E
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
SHEET
IDENTIFICATION
C
D
A
B
U S
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
C O
N T
R A
F
A
D
A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S n g i n e e r i n g I n c
L L
E N
E A
D E
L I V
E R
Y
N
O
F A
D
An O ne id a N at io n Co m pa ny
C-104
M
S
P I V
E Y
M
S
P I V
E Y
L O
F
T
S
T A
T I O
N
M
O
L
S
I T
E
P
L A
N
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
F
T
S
T A
T I O
T
L
D B
C C
A F
S
F
L
PUMP SELECTION:
NEW LIFT STATION #70448
HYDROMATIC HPGHX, 85 GPM @ 100' TDH
6.5625" DIA. IMPELLER
1750 RPM, 480V/3ph/60Hz - 7.5 HP MOTOR
RATED FOR 85 GPM @ 100' TDH
DESIGN CONDITIONS:
PRIMARY SYSTEM OPERATING CONDITION*
DESIGN POINT:
*CALCULATED SYSTEM TOTAL DYNAMIC HEAD,
CONTRACTOR SHALL PERFORM A FIELD PUMP
TEST TO VERIFY TDH AND COORDINATE WITH BASE
OPERATIONS SUPPORT CONTRACTOR PRIOR TO
ORDERING PUMPS.
LIFT STATION ELEVATIONS:
TOP OF STATION = Elev. - 8.25
INFLUENT 8" SS INVERT = Elev. - 5.50
HIGH WATER ALARM = Elev. - 5.00
LAG PUMP ON = Elev. - 4.50
LEAD PUMP ON = Elev. - 4.00
PUMPS OFF = Elev. - 3.33
SUMP INVERT = Elev. - 1.33
LIGHT
POLE
30 GPM @ 89' TDH
60 GPM @ 94' TDH
85 GPM @ 100' TDH
110 GPM @ 108' TDH
30'10' 20'0'
10'
GRAPHIC SCALE 1" = 10'
TRUE
NORTH
N
A
M b a r v i r
AutoCAD SHX Text
SCALE:
LIFT STATION 78170 - DISCHARGE RE-PIPING DETAIL
NONE
REPAIR SPECIALTY LINER TO RESEAL
AROUND 6" PVC DRAIN LINE PER LINER
MANUFACTURER'S RECOMMENDATIONS.
SECTION "A-A"
SCALE:
LIFT STATION 78170 DISCHARGE RE-PIPING SECTION
NONE
36" MAX.
T
O
PIPE STAND (TYP.)
LINK-SEAL ALL OPENINGS (TYP.)
INSTALL 2" WELDED STAINLESS STEEL NIPPLE
OR 2" DOUBLE STRAP SADDLE W/ 2" 316 S.S.
BALL VALVE & 2" S.S. PLUG
12" FL SPOOL
90° FL BEND
FL CHECK VALVE (LEVER & WEIGHT)
SEAT END ON CHECK VALVE SIDE
A
FLANGED SPOOL PIECE OR
FLANGED FILLER AS NEEDED.
SEAT END OF PLUG VALVE
90° FL BEND
PLUG VALVE (FLANGED)
12" LONG (MIN)
FLANGE SPOOL PIECE
TEE (FLANGED) TYP.
FLANGED CHECK VALVE
(LEVER & WEIGHT)
CONNECT TO EXISTING 10" FM PIPE
(INSIDE CONCRETE VAULT BELOW
GROUND)
(2) FL TEE (NOT SHOWN)
6" FL C900
PVC PIPE
E X
I S
T I N
G
C
O V
E R
8'±
EXISTING 10" EFFLUENT
FM PIPE
FINISHED GRADE
TOP SLAB
SEAT END OF PLUG VALVE
PIPE STAND (TYP.)
90° FL BEND
90° FL BEND DOWN
ISOLATION JOINT
PUMPOUT MALE 3" CAMLOCK (PO)
w/CAP (ALUM.)
BLIND FLANGE w/NIPPLE (S.S.)
REDUCER (FLANGED) IF REQUIRED
SEAT END ON CHECK VALVE SIDE
PLUG VALVE (FLANGED)
DUAL ACCESS HATCH DOORS (H-20
LOAD RATING) SHOWN OPEN,
DRILL (2),
" Ø HOLES EACH DOOR
(2) 45° FL BENDS 10" X 6"
REDUCER AND FL ADAPTER
CONNECT TO 10" FM
#5 DRILLED
EPOXY DOWEL
@ 24" O.C.
#5 @ 12" EW
6" PVC
DRAIN LINE
90° MJ BEND
(2) 45° FL BENDS
10" FL ADAPTER
THIN-SET MORTAR, SLOPE TO DRAIN
EXTERIOR JOINT
TAPE (TYP.)
E
X I S
T I N
G
V
A U
L T
6" DRAIN LINE BELOW
(2) CONCRETE PIPE
SUPPORTS
* EXISTING
CONCRETE VAULT
* CONTRACTOR SHALL FILL ANY CRACKS INSIDE
EXISTING CONCRETE VAULT WITH NON-SHRINK
GROUT THEN APPLY THREE COATS CONSEAL
(CS-55), SHERWIN WILLIAMS DTM ACRYLIC, OR
APPROVED EQUAL FOR WATERPROOF SEAL.
EXISTING
PUMPS
AND
WET WELL
1" CHAMFER
EDGES (TYP.)
RELOCATE EXISTING
VENT TO OPPOSITE SIDE
OF WET WELL, GROUT
PLUG HOLE
RELOCATED VENT
(INSIDE VAULT)
K
C-504
9.95
AIR RELEASE VALVE
W/ 1-1/2" SCH 80 PVC DRAIN PIPE
TO WET WELL
1-1/2" SCH 80 PVC
DRAIN PIPE
AIR RELEASE VALVE
D
C-503
FL PLUG VALVE W/2-INCH OPERATOR
NUT AND GEAR ACTUATOR
10" x 6" REDUCER
ATTACH TO PIPE W/
CONDUIT HANGERS
F
M
F
M
C
C
C
C
E x
E x
E x
E x
E x
E x
E x
E x
E x
F
M
X
X
F
M
S
F
S
F
S
F
S
F
W
F
M
F
M
F
M
N
G
C
C
C
C
E x
E x
E x
E x
E x
E x
E x
E x
E x
F
M
X
X
F
M
W
N
DEMOLITION FLAG NOTES:
SCALE:
NEW CONSTRUCTION SITE PLAN
1" = 10'
REPUMP LIFT STATION 78170
N
CONSTRUCTION FLAG NOTES:
9. DURING NEW DISCHARGE PIPE TIE-IN CONSTRUCTION, PHASE DISCHARGE
PIPING IN ORDER TO MAINTAIN SERVICE OF ONE PUMP. ALTERNATIVELY, THE
CONTRACTOR MAY PROVIDE A DIFFERENT PUMP BYPASS PLAN TO THE
CONTRACTING OFFICER FOR APPROVAL.
10. EXISTING ELECTRICAL PANEL, METER AND DISCONNECT TO REMAIN.
11. EXISTING MOTOR CONTROL PANEL, JUNCTION BOX, RTU, AND ANTENNA TO
REMAIN.
12. EXISTING 10" FORCE MAIN TO REMAIN.
13. RESTRAINED 90° MJ BENDS CONNECTED TO EXISTING 6" DISCHARGE PIPE JUST
OUTSIDE OF WET WELL WALL, VERTICAL 6" C-900 PVC (MJxFE), AND ABOVE
GRADE VALVE ASSEMBLY AS SHOWN IN DETAIL A AND B, THIS SHEET.
14. PIPE BOLLARD (TYP.) AT (2) SIDES.
15. CORE DRILL EXISTING CONCRETE VALVE VAULT AND WET WELL AND
CONSTRUCT 6" PVC DRAIN LINE CONNECTION, LINK-SEAL STRUCTURE
OPENINGS, REPAIR LINER AROUND PIPE INSIDE WET WELL.
16. ABOVE GROUND 6" FL PLUG VALVE AND 90° FL BEND TO 6" FL C-900 PVC
THROUGH NEW CONCRETE TOP SLAB, SEAL OPENING WITH LINK-SEAL.
17. CONSTRUCT APPROX. 8 LF 6" FL C-900 PVC FORCE MAIN WITHIN EXISTING
CONCRETE VAULT, CONNECT TO EXISTING 10" DI FORCE MAIN WITH (2) 45° FL
BENDS10" x 6" REDUCER AND 10" FL ADAPTER.
18. REINFORCED PRECAST CONCRETE VAULT TOP SLAB WITH SQUARE MANHOLE
FRAME AND DUAL SOLID HATCH LIDS WITH LIFTING HANDLES, SEE DETAIL.
PROVIDE #5 VERTICAL DOWELS @ 24" O.C. TO CONNECT TOP SLAB TO
VERTICAL WALLS OF EXISTING BOX, GROUT SEAL JOINT WITH NON-SHRINK
CEMENTATIOUS GROUT INTERIOR AND EXTERIOR. SEE DETAIL THIS SHEET.
19. GROUT SEAL ANY VISIBLE CRACKS ON THE INTERIOR OF EXISTING CONCRETE
VAULT, THEN APPLY THREE COATS CONSEAL (CS-55), SHERWIN WILLIAMS DTM
ACRYLIC, OR APPROVED EQUAL FOR WATERPROOF SEAL.
20. PROVIDE SOD RESTORATION FOR ALL DISTURBED AREAS, TYP. IN ACCORDANCE
WITH SPECIFICATION SECTION 32 92 23 BAHIA SOD CERTIFIED WEED FREE.
21. CORE DRILL HOLE AND INSTALL RELOCATED VENT PIPE WITH NON-SHRINK
EPOXY GROUT. CORE DRILL 2" HOLE FOR AIR RELEASE VALVE DRAIN SEE
DETAIL THIS SHEET.
22. PROVIDE 2" WATER SERVICE W/ BFP AND HOSE BIBB WITH CONC STAND. WET
TAP CONNECT TO EXISTING 8" WATER LINE ON THE NORTH SIDE OF
LIGHTHOUSE ROAD APPROX. 330 FEET SOUTH OF LIFT STATION SITE.
SCALE:
DEMOLITION SITE PLAN
1" = 10'
REPUMP LIFT STATION 78170
P
H
I
L
L
I
R
K
W
A
Y
L I G
H T
H O
U S
E
R
O A
D
P
H
I
L
L
I
R
K
W
A
Y
L I G
H T
H O
U S
E
R
O A
D
L
C-505
N
C-505
18 19
6x6-W 2.9x2.9 W.W.F.
OR FIBERMESH
3000 PSI CONCRETE
1" CHAMFER EDGES (TYP.)
1. PROVIDE, INSTALL AND MAINTAIN SILT FENCE (APPROX. LOCATION);
REMOVE UPON PROJECT COMPLETION.
2. PORTION OF EXISTING SANITARY FORCE MAIN TO REMAIN.
3. CUT AND REMOVE PORTION OF FORCE MAIN PIPE, VALVES, FITTINGS,
FROM INSIDE VAULT TO JUST OUTSIDE OF THE WET WELL.
4. REMOVE EXISTING CONCRETE VAULT METAL LIDS AND REMOVE
CONCRETE BOX TOP RIM SECTION.
5. REMOVE EXISTING 2" DRAIN LINE BETWEEN WET WELL AND VALVE
VAULT, CARE SHALL BE TAKEN NOT TO DAMAGE WET WELL LINER.
6. REMOVE EXISTING VENT TO BE RELOCATED AND FILL HOLE WITH A
NON-SHRINK EPOXY GROUT.
TRUE
NORTH
TRUE
NORTH
NEW CONC.
PAD
A
B
2 3
C
D
1 2 3
4 5 6
I
T
E
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
SHEET
IDENTIFICATION
C
D
A
B
U S
T
H
C
I V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
C O
N T
R A
F
A D
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S n g i n e e r i n g I n c
L L
E N
E A
D E
L I V
E R
Y
N
O
F A
D
An O ne id a N at io n Co m pa ny
C-105
M
S
P I V
E Y
M
S
P I V
E Y
R E
P U
M
F
T
S
T A
T I O
N
D
E M
O
A
N D
N E
W
S
I T
E
P
L A
N
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
F
T
S
T A
T I O
T
L
D B
C C
A F
S
F
L
SCALE:
CONCRETE PAD DETAIL
NONE
SCALE:
LIFT STATION 78170
NONE
M
C-505
30'10' 20'0'
10'
GRAPHIC SCALE 1" = 10'
A
M b a r v i r
AutoCAD SHX Text
B
2 3
C
D
1 2 3
4 5 6
I
T
E
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
SHEET
IDENTIFICATION
C
D
A
B
U S
T
H
C
I V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
C O
N T
R A
F
A D
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S n g i n e e r i n g I n c
L L
E N
E A
D E
L I V
E R
Y
N
O
F A
D
An O ne id a N at io n Co m pa ny
C-501
M
S
P I V
E Y
M
S
P I V
E Y
L O
O
F
T
S
T A
T I O
N
D E
T A
I L S
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
F
T
S
T A
T I O
T
L
D B
C C
A F
S
F
L
PLUG VALVE (FLANGED)
SEAT END OF PLUG VALVE
FLANGED CHECK VALVE
(LEAVER & WEIGHT)
OUTER ACCESS DOOR HINGES
DOUBLE DOOR ALUMINUM CHECKER
PLATE HATCH COVER CAST IN TOP SLAB
LINED PRECAST CONCRETE TOP SLAB TO
BE 4000 PSI CONCRETE WITH HATCH
OPENING CENTERED IN WET WELL UNLESS
OTHERWISE NOTED. CONCRETE &
REINFORCING TO BE CERTIFIED BY A
FLORIDA ENGINEER. DESIGNED FOR H-20
TRAFFIC LOADING.
DROP BOWL
GRAVITY SS INFLUENT LINE,
(SHOWN ROTATED FOR CLARITY)
316 S.S. CABLE HOLDER (3/8" ROD HOOKS,
ETC., SEE SPECIFICATIONS) LOCATED ON
OPPOSITE SIDE AS DISCHARGE PIPES.
SUBMERSIBLE SEWAGE PUMPS TO
BE LOCATED ALONG C.L. OF WET
WELL UNLESS OTHERWISE NOTED.
BLIND FLANGE W/ NIPPLE (S.S.)
REDUCER (FLANGED) IF REQUIRED
SEAT END ON CHECK VALVE SIDE
TEE (FLANGED) TYP.
45° (FL BEND DOWN
PUMPOUT MALE 3" CAMLOCK
(PO) W/ CAP (ALUM)
PLUG VALVE (FLANGED)
12" LONG (MIN)
FLANGE SPOOL PIECE
2" CORE DRILL
FOR DRAIN PIPE
TO 3"X45° MJ BEND AND
3" PVC SCH 80 EFFLUENT
PIPE (BELOW GROUND)
AIR RELEASE VALVE
DRAIN TO WET WELL
1-1/2" SCH 80 PVC PIPE
PLUG VALVE
(FLANGED)
FLANGED SPOOL PIECE OR FLANGED
FILLER AS NEEDED, SEE PUMP
SEPARATION NOTES.
90° BEND (FLANGED)
6" (MIN) CLEARANCE BETWEEN
PUMP BODY AND HATCH
OPENING (AROUND ALL
EDGES OF PUMP)
DUAL 2" ORANGE SAFETY GRATES ATTACH ON OPPOSITE SIDES OF
HATCH FRAME UNDER THE COVER, AS MANUFACTURED BY USF
FABRICATION, HALLIDAY, OR APPROVED EQUAL CONTRACTOR TO
ENSURE HATCH OPENING AND SAFETY GRATE DIMENSIONS WHEN
FULLY OPEN PROVIDE REQUIRED CLEARANCE, INSTALL PER
MANUFACTURER'S RECOMMENDATIONS.
A
A
90° FL BEND
12" FL SPOOL
FL CHECK VALVE (LEAVER & WEIGHT)
SEAT END ON CHECK
VALVE SIDE
HIGH LEVEL ALARM ELEV. "C"
LAG PUMP ON EVEL. "D"
LEAD PUMP ON EVEL. "E"
BOTH PUMPS OFF ELEV. "F"
WET WELL INVERT = ELEV. "G"
TOP OF CASTING = ELEV. "H"
PUMP BASE PLATE
SUBMERSIBLE SEWAGE PUMPS, EXPLOSION PROOF
LINK-SEAL OPENINGS
316 S.S. PIPE BRACE
8" EFFLUENT FM PIPE
45° MJ BEND
316 S.S.
RESTRAINT
RODS
45° FL BEND
8" FExMJ SCH 80
PVC PIPE
ELEV. "A"
INSTALL 2" WELDED STAINLESS STEEL NIPPLE OR 2" DOUBLE
STRAP SADDLE W/ 2" 316 S.S. BALL VALVE & 2" S.S. PLUG
4" POLY-AIR PCF-PLVF VENT W/ ACTIVATED CARBON STACK
FILTER 4" VENT W/ 6" DIA. SLAB OPENING (SEE NOTE 9)
FL PLUG VALVE W/ 2-INCH OPERATOR
NUT AND GEAR ACTUATOR
AIR RELEASE VALVE
DRAIN TO WET WELL
1-1/2" SCH. 80 PVC
ATTACH TO PIPE W/
CONDUIT HANGERS
FL PLUG VALVE W/ BAR OPERATOR
AND GEAR ACTUATOR
PIPE STAND (TYP.)
EXPANSION JOINT AROUND
PERIMETER
PERIMETER CONCRETE PAD
PROTECTIVE LINER TOP SLAB
AND WALL SECTION
ACCESS DOOR AND DUAL
2" ORANGE SAFETY
GRATES INSIDE, BOTH
SHOWN OPEN
1" CHAMFER EDGES (TYP.)
CONDUITS TO CONTROL PANEL
(PUMPS/TRANSMITTER/FLOATS) SEE
PUMP STATION ELECTRIC PLANS
316 STAINLESS STEEL LIFTING
CHAINS WITH 3'-0" MIN. EXCESS
316 S.S. GUIDE RAILS FOR PUMP
REMOVAL STILLING 316 S.S. PIPE CLAMP
EXTERIOR JOINT SEALANT
MEMBRANE TAPE (TYP.)
LINER TO BE APPLIED TO
VERTICAL WALLS AND TOP
FLOAT SWITCHES, ONE SHOWN
FOR CLARITY, PROVIDE 92), HIGH
LEVEL AND PUMP OFF
PRIMARY LEVEL READER BY LEVEL
TRANSMITTAL, AS MANUFACTURED
BY MERCOID MODEL PBLTX-5-50W/
ZENER BARRIER. INSTALL INSIDE 4"
PVC STILLING WELL
6" GRAVITY INFLUENT PIPE INSTALL
PVC C900 DR18 FROM UPSTREAM
SERVICE 6" FROM BOTTOM
CONTROL ELEVATION INV. ELEV. "B"
DROP BOWL 6" OUTLET
DO NOT CAP
316 STAINLESS STEEL
CLAMPING BRACKETS, SPACE
EVERY 4" OR 2 BRACKETS MIN.
8" SDR35 PVC DROP PIPE
MANUFACTURER APPLIED HDPE
SPECIALTY LINER OVER INTERIOR GROUT
316 S.S. CABLE HOLDER (3/8" ROD HOOKS,
ETC., 6 HOOKS MIN. OR AS NEEDED)
FL SCH 80 PVC PIPE
(2) 45° FL BENDS (FBE) BUTTED FACE TO
FACE ADJUST AS NECESSARY FOR PIPE
ALIGNMENT THROUGH TOP SLAB
FL ECCENTRIC REDUCER (3" X 2" FBE IF NECESSARY
BASED ON PUMP SELECTION)
BASE ELL TO BE FABRICATED BY PUMP
MANUFACTURER. BASE ELBOW TO BE SIZED FOR
EFFLUENT PIPE CONNECTION
GROUT FROM BASE PLATE TO A HEIGHT
OF 1' ABOVE BOTTOM ALL AROUND WITH
CLASS "C" CONCRETE
12" #57 STONE OR PEA GRAVEL
UNDISTURBED SOIL MIN. BEARING
CAPACITY: 2000 LB/SQ FT
SCALE:
LIFT STATION - PLAN
NONE
ELEV. "A"
F
C-503
B
C-501
C
C-501
D
C-503
K
C-504
FIBERGLASS REINFORCED POLYMER WETWELL MEETING A.S.T.M.
D3753 OR PRECAST CONCRETE WETWELL MEETING A.S.T.M. C-478
STANDARD, SHOP DRAWINGS SIGNED BY FLORIDA P.E., PRECAST
BOTTOM SLAB BASE SHALL CAST INTEGRALLY WITH BOTTOM
SECTION (OR)
ENTIRE INSIDE SURFACE OF CONCRETE WETWELL & TOP SLAB
SHALL BE LINED WITH APPROVED LINER. LINER INSTALLER MUST BE
CERTIFIED BY LINER MANUFACTURER. SUBMIT CERTIFICATION WITH
SHOP DRAWING SUBMITTAL. THE EXCAVATED HOLE SHALL BE DRY
(DE-WATERED) DURING THE WETWELL INSTALLATION. SEE NOTE 13.
A
C-501
J
C-504
FINISHED
GRADE
SCALE:
LIFT STATION WET WELL
NONE
SECTION "A - A"
SCALE:
LIFT STATION CONDUIT PENETRATION
NONE
C
C-501
SCALE:
LIFT STATION PAD
NONE
B
C-501
SCALE:
FIBERGLASS (FRP) WET WELL STRUCTURE
NONE
A
C-501
1" CHAMFER EDGES (TYP.)
LIFT STATION CONCRETE SLAB
INSTALL FRP
WETWELL PER
MANUFACTURES
RECOMMENDATIONS
FRAME CONCRETE
FRP WETWELL SHALL MEET
A.S.T.M. D3753 AND SHALL
BE ONE CONTINUOUS BASIN
WITHOUT ANY JOINTS
PROVIDE SAME FOUNDATION
MATERIALS BELOW BASIN AS
SHOWN FOR CONCRETE WET
WELL OR PROVIDE 10" MIN.
CONCRETE PAD
PROVIDE 6" GROUT FOR
ANCHORING OF PUMP BASE
PLATE AND RAIL TO BOTTOM OF
WET WELL, CLASS "C" CONCRETE
BALLAST
CONCRETE 30 CF
MIN. COVER ENTIRE
BOTTOM
ANTI-FLOTATION
FLANGE
H E
I G
R
E Q
U I R
Y
L
I F
T
S
T A
T I O
N
D
E T
A I L
S
6 x 6 - W2.9 x 2.9 W.W.F. OR
FIBERMESH
3000 PSI CONCRETE
1" CHAMFER EDGES (TYP.)
FIBERGLASS WET WELL
OR CONCRETE W/ LINER
PROVIDE LINK -SEAL
FOR ALL WALL AND
STRUCTURE TOP
PENETRATIONS
LOCC
LIFT STATION
27214
ELEV.
"A"
8.25
"B"
"C"
"D"
"E"
"F"
"G"
"H"
PHOTO OPS
SET POINT
HEIGHTS
PHOTO OPS
LIFT STATION
44406
5.50
5.00
4.50
4.00
3.33
1.33
0.33
9.00
5.00
4.50
4.00
3.50
3.00
1.00
0.00
3.50
3.00
2.50
2.00
0.00
LOCC
SET POINT
HEIGHTS
3.67
3.17
2.67
2.00
0.00
6" 6"
30°
LIFTING
BAIL
8"
5"
3'
MAX.
6"
30"
PIPE STAND
(TYP.)
T
O
5'
C
O V
E R
6"
18"
6"
6' DIA.
12"
30°
12"
12"
GENERAL NOTES:
SANITARY SEWERAGE NOTES:
1. ALL EXPOSED FERROUS METAL SHALL BE PRIMED WITH TWO COATS OF EXTERIOR ENAMEL PAINT, CCAFS OLIVE GREEN.
2. FIBERGLASS WET WELL SHALL BE FRP BASIN MEETING ASTM D3753 SUITABLE FOR THE APPLICATION AND DIMENSIONS SHOWN
ON THE DRAWINGS. THE WET WELL SHALL BE INSTALLED PER THE FRP MANUFACTURER'S RECOMMENDATIONS.
3. BASE AND FIRST RISER UNIT OF PRECAST STRUCTURES TO BE CAST MONOLITHIC.
4. VALVES, ELBOWS, AND SPOOL PIECES SHALL BE SIZED TO PERMIT EASY REMOVAL OF CHECK VALVE SPINDLES WITH MIN.
CLEARANCES AS SHOWN FOR 6" DIA. PIPE AND SMALLER. CLEARANCES SHALL INCREASE AS REQUIRED FOR LARGER PIPE SIZES.
5. ALL LOCATIONS WHERE PIPES ENTER OR LEAVE THE WET WELL SHALL BE MADE WATER-TIGHT WITH WALL SLEEVES AND
LINK-SEAL.
6. THERE SHALL BE NO VALVES OR ELECTRICAL JUNCTION BOXES IN THE WET WELL.
7. WET WELL COVERS SHALL BE ALUMINUM WITH 316 S. STL. HARDWARE AND LOCK BRACKET. SIZE AS REQUIRED BY PUMP
MANUFACTURER.
8. ALL HARDWARE IN WET WELL AND ABOVEGROUND SHALL BE 316 STAINLESS STEEL; ALL NUTS/BOLTS/ WASHERS SHALL BE
CONNECTED USING LOCK WASHERS.
9. FLEXIBLE COUPLINGS SHALL BE SLEEVE TYPE.
10. INSTALL AN ADJUSTABLE STAINLESS STEEL PIPE STAND UNDER EACH CHECK VALVE AT THE EDGE OF THE WET WELL.
11. SEE ELECTRICAL PLANS, FOR CONTROL PANEL CONNECTIONS.
12. CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY PIPING, VALVES, WET WELL, MANHOLES, ACCESSORIES, AND
CONTROLS, FOR A COMPLETE AND OPERABLE SANITARY SEWAGE LIFT STATION.
13. FIBERGLASS WET WELL STRUCTURE IS THE PREFERRED MATERIAL. IF A SUITABLE FIBERGLASS STRUCTURE IS NOT USED, A
CONCRETE WET WELL SHALL HAVE THE ENTIRE INSIDE SURFACE OF WET WELL & TOP SLAB LINED WITH AGRU SURE GRIP HDPE
LINER, OR EQUAL APPROVED LINER. LINER INSTALLER MUST BE CERTIFIED BY LINER MANUFACTURER. SUBMIT CERTIFICATION
WITH SHOP DRAWING SUBMITTAL.
14. ALL ABOVE GROUND EXPOSED FORCE MAIN PIPE AND FITTINGS SHALL BE PAINTED WITH A SAFETY GREEN LATEX, OR OTHER
COLOR APPROVED BY THE CONTRACTING OFFICER.
15. CONTRACTOR SHALL COORDINATE THE FINAL PUMP SELECTION WITH BASE OPERATIONS SUPPORT CONTRACTOR PRIOR TO
ORDERING TO CHECK FOR COMMON PUMPS STOCKED AND AVAILABILITY OF MATCHING REPLACEMENT PUMPS AND PARTS.
16. THE CONTRACTOR SHALL SUBMIT A PLAN AND BE RESPONSIBLE FOR TEMPORARY PUMP STATION SEWAGE BYPASS AT EACH LIFT
STATION TO SUPPORT THE UTILITY TIE-IN CONNECTIONS AND TRANSFER SERVICE TO THE NEW LIFT STATION. REQUESTING A
UTILITY OUTAGE WITHOUT ALTERNATIVE MEANS TO PROVIDE SEWAGE COLLECTION IS NOT ACCEPTABLE.
1. WHERE POTABLE WATER AND SANITARY SEWER MAIN CANNOT AVOID CROSSING WITH LESS THAN TWELVE (12) INCHES OF
VERTICAL CLEARANCE OR WHERE THE SEWER MAIN IS ABOVE THE WATER MAIN, THE SEWER MAIN SHALL BE ENCASED WITH
CONCRETE OR UPGRADED TO PRESSURE RATED PVC PIPE (MEETING THE AWWA C-900 OR C-905 SPECIFICATION) FOR A
MINIMUM LENGTH OF TWENTY (20) FEET, CENTERED ON THE POINT OF CROSSING. A MINIMUM HORIZONTAL SEPARATION OF
SIX (6) FEET (EDGE TO EDGE) BETWEEN POTABLE WATER MAINS AND SEWER MAINS SHALL BE MAINTAINED WHEN AT ALL
POSSIBLE. WHEN THE 6-FOOT HORIZONTAL SEPARATION CANNOT BE MAINTAINED, THE SEWER MAIN SHALL BE INSTALLED
WITH AT LEAST 3-FEET OF SEPARATION AND ON AN UNDISTURBED EARTH SHELF AT LEAST 6" BELOW A POTABLE WATER
MAIN. THE SEPARATION REQUIREMENTS ARE PROVIDED ON SHEET C-504; THE CONTRACTOR SHALL NOTIFY THE
ENGINEER THROUGH THE CONTRACTING OFFICER OF ANY LOCATIONS WHERE THE REQUIRED SEPARATION CANNOT BE MET TO
DETERMINE APPROPRIATE ACTION.
2. TESTING AND INSPECTION:
A. GRAVITY SEWERS SHALL BE TESTED TO ENSURE THAT INFILTRATION DOES NOT EXCEED 50 GPD/INCH DIA/MILE.
B. PROVIDE DEFLECTION TEST, SEE NOTE 10.
C. FORCE MAIN SHALL BE PRESSURE TESTED AT 100 PSI MINIMUM FOR A MINIMUM OF 1 HOUR. A LEAKAGE TEST SHALL BE
PERFORMED CONCURRENTLY. LEAKAGE SHALL NOT EXCEED 0.25 GAL/HR/1000 LF OF 3-INCH OR 0.33 GAL/HR/1000 LF OF
8-INCH FORCE MAIN.
D. VACUUM TEST NEW SEWER MANHOLES IN ACCORDANCE WITH ASTM C 1244.
3. ALL SANITARY SEWER COLLECTION SYSTEM CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST REVISION OF THE
UFC 3-240-01 "WASTEWATER COLLECTION."
4. ALL GRAVITY SANITARY SEWER LINES SHALL BE PVC (ASTM D3034, SDR35) WITH ELECTRO-METRIC GASKETS MEETING ASTM
F477 UNLESS OTHERWISE NOTED. PVC FORCEMAINS SHALL MEET ASTM D 2241 SDR-21 (PC200), OR AWWA C900 DR-18 (PC235).
HDPE FORCEMAINS SHALL BE AWWA C906 DR11 (PC160) W/DIP O.D. HDPE PIPE SHALL BE HEAT FUSED BY PERSONNEL AND
EQUIPMENT APPROVED BY THE PIPE REPRESENTATIVE AND BE PROVIDED WITH MJ ADAPTERS (RATED 160 PSI) FOR ELECTRO
FUSION APPLICATION. ALL GRAVITY SEWER AND FORCEMAIN PIPE SHALL BE COLOR-CODED GREEN FOR IDENTIFICATION.
5. PROVIDE ENGINEER WITH AS-BUILT SEWAGE COLLECTION SYSTEM INFORMATION FROM A FLORIDA REGISTERED PROFESSIONAL
LAND SURVEYOR, AT NO ADDITIONAL COST TO THE OWNER, AS FOLLOWS:
HORIZONTAL LOCATION OF FORCE MAIN AND ANY SIGNIFICANT CHANGE IN ELEVATION (COVER) DISTANCE BETWEEN MANHOLES
MANHOLE & SERVICE LATERAL LOCATIONS FROM DOWNSTREAM MANHOLE INVERT, MANHOLE RIM AND SERVICE WYE
ELEVATIONS, CLEARANCE BETWEEN GRAVITY OR PRESSURE SEWERS AND WATERMAINS COMPUTED SEWER SLOPES THE
SEWER AS-BUILT INFORMATION IS DUE PRIOR TO PAVING AND SODDING. CONTRACTOR SHALL PROVIDE SURVEYOR
24-HOUR NOTICE IN ORDER TO OBTAIN ESSENTIAL LOCATIONS AND ELEVATIONS.
6. VENTILATE PIPE DURING CONSTRUCTION AS REQUIRED TO ELIMINATE REFRACTION ERRORS IN SETTING ELEVATIONS.
7. PROVIDE FERNCO COUPLINGS, OR APPROVED EQUAL, AT ALL CONNECTIONS OF PVC TO D.I. SEWER PIPE.
8. COMPACTION OF BACKFILL WILL BE TESTED TO 98% OF AASHTO T-180 UNDER ROADWAYS, 95% OF AASHTO T-180 UNDER OPEN
AREAS.
9. WET WELL VENT SHALL BE BY REX-BAC-T POLYOK POLY-AIR PCF-PLVF 4" ACTIVATED CARBON STACK FILTER FOR ODOR
CONTROL, OR APPROVED EQUAL.
10. DEFLECTION TESTS: TESTING IS REQUIRED AFTER THE FINAL BACKFILL HAS BEEN IN PLACE FOR AT LEAST 30 DAYS TO PERMIT
STABILIZATION OF THE SOIL-PIPE SYSTEM. TEST PIPE USING A RIGID BALL OR MANDREL FOR THE DEFLECTION TEST WITH A
DIAMETER OF NOT LESS THAN 95.0% OF THE BASE INSIDE DIAMETER OF THE PIPE SPECIFIED IN THE APPENDIX TO ASTM D3034.
THE TEST DEVICE SHALL BE PULLED THROUGH BY HAND.
11. PLUG UNUSED SANITARY SEWER SERVICES AND MAINS WITH NON-SHRINK GROUT.
12. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER PRIOR TO REMOVAL OF SANITARY SEWER PIPE OR ELECTRICAL SYSTEM
COMPONENTS IN ORDER FOR NOTICES OF SERVICE OUTAGE TO BE DELIVERED, IF OUTAGE IS REQUIRED. WORK SEQUENCE
SHALL BE PLANNED SO AS TO MINIMIZE UTILITY SERVICE OUTAGES.
13. ALL PLUG VALVES SHALL BE PROVIDED WITH A SERVICE GEAR CAPABLE OF HOLDING AT LEAST 100 PSI TEST PRESSURE FROM
BOTH DIRECTIONS; BURIED AND ABOVEGROUND VALVES SHALL BE EQUIPPED WITH 2" NUT ACTUATOR.
14. ALL D.I. FITTINGS USED INSIDE WET WELL SHALL BE FUSION BONDED EPOXY (FBE) COATED.
4" MIN.
FLANGE
5"
A
M b a r v i r
SUBMERSIBLE SEWAGE PUMPS TO BE
LOCATED ALONG C.L. OF WET WELL
UNLESS OTHERWISE NOTED.
GRAVITY SS INFLUENT LINE,
(SHOWN ROTATED FOR CLARITY)
DOUBLE DOOR ALUMINUM
CHECKER PLATE HATCH
COVER CAST IN TOP SLAB.
LINED PRECAST CONCRETE TOP SLAB TO BE
4000 PSI CONCRETE WITH HATCH OPENING
CENTERED IN WETWELL UNLESS OTHERWISE
NOTED. CONCRETE & REINFORCING TO BE
CERTIFIED BY A FLORIDA ENGINEER.
DESIGNED FOR H-20 TRAFFIC LOADING.
18"
DROP BOWL
SCALE:
TRI-PUMP LIFT STATION - PLAN
NONE
6" (MIN) CLEARANCE
BETWEEN PUMP BODY AND
HATCH OPENING (AROUND
ALL EDGES OF PUMP)
5"
PERIMETER CONCRETE PAD
316 S.S. GUIDE RAILS FOR PUMP REMOVAL
SUBMERSIBLE SEWAGE PUMPS, EXPLOSION
PROOF SOFT START FOR MOTORS
GROUT FROM BASE PLATE TO A HEIGHT
OF 1' ABOVE BOTTOM ALL AROUND
WITH CLASS "C" CONCRETE
BASE ELL TO BE FABRICATED BY PUMP
MANUFACTURER. BASE ELBOW TO BE SIZED FOR
EFFLUENT PIPE CONNECTION.
FIBERGLASS REINFORCED POLYMER WETWELL MEETING
A.S.T.M. D3753 OR PRECAST CONCRETE WETWELL MEETING
A.S.T.M. C-478 STANDARD, SHOP DRAWINGS SIGNED BY FLORIDA
P.E., PRECAST BOTTOM SLAB BASE SHALL CAST INTEGRALLY
WITH BOTTOM SECTION. (OR)
ENTIRE INSIDE SURFACE OF CONCRETE WETWELL & TOP SLAB
SHALL BE LINED WITH APPROVED LINER. LINER INSTALLER MUST
BE CERTIFIED BY LINER MANUFACTURER. SUBMIT
CERTIFICATION WITH SHOP DRAWING SUBMITTAL. THE
EXCAVATED HOLE SHALL BE DRY (DE-WATERED) DURING THE
WET WELL INSTALLATION. SEE NOTE 13.
316 S.S. PIPE BRACE
316 STAINLESS STEEL LIFTING CHAINS
WITH 3'-0" MIN. EXCESS
FL SCH 80 PVC PIPE
PUMP BASE PLATE
EL. "A"
CONDUITS TO CONTROL PANEL
(PUMPS/TRANSMITTER/FLOATS)
SEE PUMP STATION ELECTRIC PLANS
LINER TO BE APPLIED TO
VERTICAL WALLS AND TOP
MANUFACTURER APPLIED HDPE SPECIALTY
LINER OVER INTERIOR GROUT
EXTERIOR JOINT SEALANT
MEMBRANE TAPE (TYP.)
UNDISTURBED SOIL MIN. BEARING
CAPACITY: 2000 LB/SQ FT
12" #57 STONE OR PEA GRAVEL
6"
MAX
FLOAT SWITCHES, ONE SHOWN
FOR CLARITY, PROVIDE (2),
HIGH LEVEL AND PUMP OFF
LIFTING
BAIL
6"6"
3'
EXPANSION JOINT AROUND PERIMETER
PROTECTIVE LINER TOP SLAB
AND WALL SECTIONS
10"
30°
TOP OF CASTING = EL. "H"
HIGH LEVEL ALARM ELEV. "C"
LAG PUMP ON ELEV. "D"
BOTH PUMPS OFF ELEV. "F"
LEAD PUMP ON ELEV. "E"
30"
WET WELL INVERT = EL. "G"
10' DIA.
T
O
PIPE STAND (TYP.)
FL PLUG VALVE W/2-INCH
LINK-SEAL OPENINGS
INSTALL 2" WELDED STAINLESS STEEL
NIPPLE OR 2" DOUBLE STRAP SADDLE W/
2" 316 S.S. BALL VALVE & 2" S.S. PLUG
12" FL SPOOL
90° FL BEND
FL CHECK VALVE (LEVER & WEIGHT)
SEAT END ON CHECK
VALVE SIDE
A
FLANGED SPOOL PIECE OR FLANGED
FILLER AS NEEDED. SEE PUMP
SEPARATION NOTES.
SEAT END OF PLUG VALVE
90° BEND (FLANGED)
PLUG VALVE (FLANGED)
12" LONG (MIN)
FLANGE SPOOL PIECE
PUMPOUT MALE 3" CAMLOCK
(PO) w/CAP (ALUM)
BLIND FLANGE w/NIPPLE (S.S.)
REDUCER (FLANGED) IF REQUIRED
SEAT END ON CHECK VALVE SIDE
TEE (FLANGED) TYP.
PLUG VALVE (FLANGED)
FLANGED CHECK VALVE
(LEVER & WEIGHT)
TO 3"x45° MJ BEND AND
3" PVC SCH 80 EFFLUENT
PIPE (BELOW GROUND)
6" FExMJ SCH 80
PVC PIPE
C
O V
E R
5'
PLUG
VALVE
(FLANGED)
45° MJ BEND
8" EFFLUENT FM PIPE
8" SDR35 PVC DROP PIPE
EL. "A"
316 S.S.
RESTRAINT
RODS
316 STAINLESS STEEL CLAMPING BRACKETS,
SPACE EVERY 4' OR 2 BRACKETS MIN.
10"
OPERATOR NUT AND GEAR ACTUATOR
(2) 45° FL BENDS (FBE) BUTTED FACE TO
FACE ADJUST AS NECESSARY FOR PIPE
ALIGNMENT THROUGH TOP SLAB
GENERAL NOTES:
1. ALL EXPOSED FERROUS METAL SHALL BE PRIMED WITH TWO COATS OF EXTERIOR ENAMEL PAINT, CCAFS OLIVE GREEN.
2. FIBERGLASS WET WELL SHALL BE FRP BASIN MEETING ASTM D3753 SUITABLE FOR THE APPLICATION AND DIMENSIONS SHOWN ON
THE DRAWINGS. THE WET WELL SHALL BE INSTALLED PER THE FRP MANUFACTURER'S RECOMMENDATIONS.
3. BASE AND FIRST RISER UNIT OF PRECAST STRUCTURES TO BE CAST MONOLITHIC.
4. VALVES, ELBOWS, AND SPOOL PIECES SHALL BE SIZED TO PERMIT EASY REMOVAL OF CHECK VALVE SPINDLES WITH MIN.
CLEARANCES AS SHOWN FOR 6" DIA. PIPE AND SMALLER. CLEARANCES SHALL INCREASE AS REQUIRED FOR LARGER PIPE SIZES.
5. ALL LOCATIONS WHERE PIPES ENTER OR LEAVE THE WET WELL SHALL BE MADE WATER-TIGHT WITH WALL SLEEVES AND LINK-SEAL.
6. THERE SHALL BE NO VALVES OR ELECTRICAL JUNCTION BOXES IN THE WET WELL.
7. WET WELL COVERS SHALL BE ALUMINUM WITH 316 S. STL. HARDWARE AND LOCK BRACKET. SIZE AS REQUIRED BY PUMP
MANUFACTURER.
8. ALL HARDWARE IN WET WELL AND ABOVEGROUND SHALL BE 316 STAINLESS STEEL; ALL NUTS/BOLTS/ WASHERS SHALL BE
CONNECTED USING LOCK WASHERS.
9. FLEXIBLE COUPLINGS SHALL BE SLEEVE TYPE.
10. INSTALL AN ADJUSTABLE STAINLESS STEEL PIPE STAND UNDER EACH CHECK VALVE AT THE EDGE OF THE WET WELL.
11. SEE ELECTRICAL PLANS, FOR CONTROL PANEL CONNECTIONS.
12. CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY PIPING, VALVES, WET WELL, MANHOLES, ACCESSORIES, AND
CONTROLS, FOR A COMPLETE AND OPERABLE SANITARY SEWAGE LIFT STATION.
13. FIBERGLASS WET WELL STRUCTURE IS THE PREFERRED MATERIAL. IF A SUITABLE FIBERGLASS STRUCTURE IS NOT USED, A
CONCRETE WET WELL SHALL HAVE THE ENTIRE INSIDE SURFACE OF WET WELL & TOP SLAB LINED WITH AGRU SURE GRIP HDPE
LINER, OR EQUAL APPROVED LINER. LINER INSTALLER MUST BE CERTIFIED BY LINER MANUFACTURER. SUBMIT CERTIFICATION WITH
SHOP DRAWING SUBMITTAL.
14. ALL ABOVE GROUND EXPOSED FORCE MAIN PIPE AND FITTINGS SHALL BE PAINTED WITH A SAFETY GREEN LATEX, OR OTHER COLOR
APPROVED BY THE CONTRACTING OFFICER.
15. CONTRACTOR SHALL COORDINATE THE FINAL PUMP SELECTION WITH BASE OPERATIONS SUPPORT CONTRACTOR PRIOR TO
ORDERING TO CHECK FOR COMMONPUMPS STOCKED AND AVAILABILITY OF MATCHING REPLACEMENT PUMPS AND PARTS.
16. THE CONTRACTOR SHALL SUBMIT A PLAN AND BE RESPONSIBLE FOR TEMPORARY PUMP STATION SEWAGE BYPASS AT EACH LIFT
STATION TO SUPPORT THE UTILITY TIE-IN CONNECTIONS AND TRANSFER SERVICE TO THE NEW LIFT STATION. REQUESTING A
UTILITY OUTAGE WITHOUT ALTERNATIVE MEANS TO PROVIDE SEWAGE COLLECTION IS NOT ACCEPTABLE.
SANITARY SEWERAGE NOTES:
1. WHERE POTABLE WATER AND SANITARY SEWER MAIN CANNOT AVOID CROSSING WITH LESS THAN TWELVE (12) INCHES OF VERTICAL
CLEARANCE OR WHERE THE SEWER MAIN IS ABOVE THE WATER MAIN, THE SEWER MAIN SHALL BE ENCASED WITH CONCRETE OR
UPGRADED TO PRESSURE RATED PVC PIPE (MEETING THE AWWA C-900 OR C-905 SPECIFICATION) FOR A MINIMUM LENGTH OF TWENTY
(20) FEET, CENTERED ON THE POINT OF CROSSING. A MINIMUM HORIZONTAL SEPARATION OF SIX (6) FEET (EDGE TO EDGE) BETWEEN
POTABLE WATER MAINS AND SEWER MAINS SHALL BE MAINTAINED WHEN AT ALL POSSIBLE. WHEN THE 6-FOOT HORIZONTAL
SEPARATION CANNOT BE MAINTAINED, THE SEWER MAIN SHALL BE INSTALLED WITH AT LEAST 3-FEET OF SEPARATION AND ON AN
UNDISTURBED EARTH SHELF AT LEAST 6" BELOW A POTABLE WATER MAIN. THE SEPARATION REQUIREMENTS ARE PROVIDED ON SHEET
C-504; THE CONTRACTOR SHALL NOTIFY THE ENGINEER THROUGH THE CONTRACTING OFFICER OF ANY LOCATIONS WHERE THE
REQUIRED SEPARATION CANNOT BE MET TO DETERMINE APPROPRIATE ACTION. SEE DETAIL C-505.
2. TESTING AND INSPECTION:
A. GRAVITY SEWERS SHALL BE TESTED TO ENSURE THAT INFILTRATION DOES NOT EXCEED 50 GPD/INCH DIA/MILE.
B. PROVIDE DEFLECTION TEST, SEE NOTE 10.
C. FORCE MAIN SHALL BE PRESSURE TESTED AT 100 PSI MINIMUM FOR A MINIMUM OF 1 HOUR. A LEAKAGE TEST
SHALL BE PERFORMED CONCURRENTLY. LEAKAGE SHALL NOT EXCEED 0.50 GAL/HR/1000 LF OF 6-INCH OR 0.67 GAL/HR/1000 LF
OF 8-INCH FORCE MAIN.
D. VACUUM TEST NEW SEWER MANHOLES IN ACCORDANCE WITH ASTM C 1244.
3. ALL SANITARY SEWER COLLECTION SYSTEM CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST REVISION OF THE UFC
3-240-01 "WASTEWATER COLLECTION."
4. ALL GRAVITY SANITARY SEWER LINES SHALL BE PVC (ASTM D3034, SDR35) WITH ELECTRO-METRIC GASKETS MEETING ASTM F477
UNLESS OTHERWISE NOTED. PVC FORCEMAINS SHALL MEET ASTM D 2241 SDR-21 (PC200), OR AWWA C900 DR-18 (PC235). HDPE
FORCEMAINS SHALL BE AWWA C906 DR11 (PC160) W/DIP O.D. HDPE PIPE SHALL BE HEAT FUSED BY PERSONNEL AND EQUIPMENT
APPROVED BY THE PIPE REPRESENTATIVE AND BE PROVIDED WITH MJ ADAPTERS (RATED 160 PSI) FOR ELECTRO FUSION APPLICATION.
ALL GRAVITY SEWER AND FORCEMAIN PIPE SHALL BE COLOR-CODED GREEN FOR IDENTIFICATION.
5. PROVIDE ENGINEER WITH AS-BUILT SEWAGE COLLECTION SYSTEM INFORMATION FROM A FLORIDA REGISTERED PROFESSIONAL LAND
SURVEYOR, AT NO ADDITIONAL COST TO THE OWNER, AS FOLLOWS:
HORIZONTAL LOCATION OF FORCE MAIN AND ANY SIGNIFICANT CHANGE IN ELEVATION (COVER) DISTANCE BETWEEN MANHOLES
MANHOLE & SERVICE LATERAL LOCATIONS FROM DOWNSTREAM MANHOLE INVERT, MANHOLE RIM AND SERVICE WYE ELEVATIONS
CLEARANCE BETWEEN GRAVITY OR PRESSURE SEWERS AND WATERMAINS COMPUTED SEWER SLOPES THE SEWER AS-BUILT
INFORMATION IS DUE PRIOR TO PAVING AND SODDING. CONTRACTOR SHALL PROVIDE SURVEYOR 24-HOUR NOTICE IN ORDER TO
OBTAIN ESSENTIAL LOCATIONS AND ELEVATIONS.
6. VENTILATE PIPE DURING CONSTRUCTION AS REQUIRED TO ELIMINATE REFRACTION ERRORS IN SETTING ELEVATIONS.
7. PROVIDE FERNCO COUPLINGS, OR APPROVED EQUAL, AT ALL CONNECTIONS OF PVC TO D.I. SEWER PIPE.
8. COMPACTION OF BACKFILL WILL BE TESTED TO 98% OF AASHTO T-180 UNDER ROADWAYS, 95% OF AASHTO T-180 UNDER OPEN AREAS.
9. WET WELL VENT SHALL BE BY REX-BAC-T POLYOK POLY-AIR PCF-PLVF 4" ACTIVATED CARBON STACK FILTER FOR ODOR CONTROL, OR
APPROVED EQUAL.
10. DEFLECTION TESTS: TESTING IS REQUIRED AFTER THE FINAL BACKFILL HAS BEEN IN PLACE FOR AT LEAST 30 DAYS TO PERMIT
STABILIZATION OF THE SOIL-PIPE SYSTEM. TEST PIPE USING A RIGID BALL OR MANDREL FOR THE DEFLECTION TEST WITH A DIAMETER
OF NOT LESS THAN 95.0% OF THE BASE INSIDE DIAMETER OF THE PIPE SPECIFIED IN THE APPENDIX TO ASTM D3034. THE TEST DEVICE
SHALL BE PULLED THROUGH BY HAND.
11. PLUG UNUSED SANITARY SEWER SERVICES AND MAINS WITH NON SHRINK GROUT.
12. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER PRIOR TO REMOVAL OF SANITARY SEWER PIPE OR ELECTRICAL SYSTEM
COMPONENTS IN ORDER FOR NOTICES OF SERVICE OUTAGE TO BE DELIVERED, IF OUTAGE IS REQUIRED. WORK SEQUENCE SHALL BE
PLANNED SO AS TO…
This is the start of the file's text. The full file is on GovTribe.