B320_DRAWING_-_PAFP104.pdf

PDF 73 KB Posted

Attached to
Repair Base Fire Systems
Solicitation number
F8R3CE7177AW02-01
Issued by

About this file

B320 DRAWING - 4

View the file

Other files

File Type Posted
MASTER_Q&A_DOCUMENT.pdf PDF
B320_DRAWING_-_PAFP101.pdf PDF
B320_DRAWING_-_PAFP105.pdf PDF
B320_DRAWING_-_PAFP201.pdf PDF
B320_DRAWING_-_PAFP106.pdf PDF
B320_DRAWING_-_PAFP102.pdf PDF
B320_DRAWING_-_PAFP103.pdf PDF
B258_Fire_Alarm_Control_panel__4.jpg JPG image
B258_Fire_Alarm_Control_panel__5.jpg JPG image
B258_Fire_Alarm_Control_panel__2.jpg JPG image
B258_Fire_Alarm_Control_panel__1.jpg JPG image
B258_Fire_Alarm_Control_panel__6.jpg JPG image
B258_Fire_Alarm_Control_panel__3.jpg JPG image
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE: 1/4"=1'-0"

WET PIPE SPRINKLER SYSTEMS

PARTIAL FLOOR PLAN-

FP104

ADMIN. AREA

(LH)

BLADDER MAINTENANCE ROOM

(OH-3)

STORAGE

ROOM

FROM EAST

SUPPORT AREA

AFFF ROOM

(OH-2)

MECHANICAL ROOM

(OH-2)

N

N

400 HZ

POWER ROOM

(OH-2)

ELECTRICAL ROOM

(OH-2)

COMM. ROOM

(OH-2)

INSPECTOR'S

TEST

CONTINUOUS LENGTH OF PIPE THIS SECTION

USE OF FITTINGS PROHIBITED

TO NORTH

ADMIN/SUPPORT

AREA

12'8'4'2'0 1'

SCALE: 1/4" = 1'-0"

4" WET PIPE

SPRINKLER

RISER

4"

LENGTH VARIES

12"

1" x 0'-2" NIPPLE

NOT TO SCALE

ARMOVER SPRINKLER FEED

BRANCH LINE

L L

CEILING TILE

C OF HEAD AND C OF

GYPSUM CEILING

HEAD (SEE DETAIL)

RECESSED SPRINKLER

1" DROP NIPPLE

CEILING

RECESSED CEILING ESCUTCHEON

FUSIBLE ELEMENT

HEAD

PENDENT SPRINKLER

RECESSED SPRINKLER

NOT TO SCALE

FP104

FP104

O 'K O N

C O M P A N Y

R

EM

A R K S

D A

TE

N O

REVISIONS

PROJECT NO.: 9141

DATE:

CHECKED:

DRAWN:

SHEET NUMBER:

En gi ne er s/

D es ig ne rs

P ea ch tr ee S tr ee t N .E

Su it e

A tl an ta G eo rg ia

(4

5-

FU

EL

S

YS

TE

M S

M A

IN

TE

N A N C E D O C K

1s t A

IR

R

EF

U

EL

IN

G W

IN

G

P

IT

TS

B U R G H I N

TE

R N A

TI

O N A L A

IR

P O R T, P

A

P

EN

N

SY

LV

A N

IA

A

IR

N

A

TI

O N A L G U A R D

P R O

JE

C T

JL

SQ

12/5/94

FINAL SUBMITTAL

1" 14'-0"

1" 1 1/4" 14'-0"

1 1/4" 12'-6"

1" 14'-0"

1 1/4" 14'-0"

1 1/4" 12'-6"

1" 14'-0"

1 1/4" 14'-0"

1 1/4" 12'-6"

1 1/2" 6'-0"

1 1/2" 6'-0"

1 1/2" 6'-0"

1 1/2" 6'-0"

1 1/4" 8'-6"

1 1 /4

9'- 0"

1'- 0"

1"

11' -0

1 1/4"

1" 6'-

6"

1 1 /4

3'- 0"

1 1/4" 2'-0" 4'-9"

1/

2" 8' 0"

3' 6"

1/

2" 5' 0"2"

1'-0"

1"

4'- 0"

1'-9"

2'-6" 4"3'-3" 1'-3"

4"

RN

1/

2"x '-9

RN

"x 5'-

6"

9"

6"

4"66'-0"

3"6'-6"

2 1/2" 10'-9"

1 1/4"2'-0" 1 1/4"

7'-6"

1"6'-3" 3"

3'- 9"

3'- 6"

5'- 9"

1 1/4" 4'-0"

1" 11'-0"

1" 11'-0"

11'-0" 2 1/2" 2 1/2"

5'-6"1'-3"

1'-9"

FLUSHING CONN.

1 1/4" MIN.

1/

2" 0"

8' 0"

1/

2"

INSPECTOR'S

TEST

1 1/2" 8'-6"

1 1/4"

11'-0"

1 1/4"

12'-0"

1"

11'-0"

1 1/4" 7'-0"

1 1/4" 12'-0"

1" 11'-0"

SEE

DETAIL 2

2'

2" 6'-9"

2" 6'-0" 3'-0"

2" 5' 0"

2' 0"

1 1/4" 5'-6"

1"

7'-0"

1 1/4" 5'-3"

2' 0"

2' 6"

1"

1 1/4" 6'-3"

1" 10'-0"

1 1/4" 5'-0"

1 1/4" MIN.

FLUSHING CONN.

Model

File details come from the government source that posted it. Updated .