B320_DRAWING_-_PAFP104.pdf
PDF 73 KB Posted
- Attached to
- Repair Base Fire Systems
- Solicitation number
- F8R3CE7177AW02-01
About this file
B320 DRAWING - 4
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MASTER_Q&A_DOCUMENT.pdf | ||
| B320_DRAWING_-_PAFP101.pdf | ||
| B320_DRAWING_-_PAFP105.pdf | ||
| B320_DRAWING_-_PAFP201.pdf | ||
| B320_DRAWING_-_PAFP106.pdf | ||
| B320_DRAWING_-_PAFP102.pdf | ||
| B320_DRAWING_-_PAFP103.pdf | ||
| B258_Fire_Alarm_Control_panel__4.jpg | JPG image | |
| B258_Fire_Alarm_Control_panel__5.jpg | JPG image | |
| B258_Fire_Alarm_Control_panel__2.jpg | JPG image | |
| B258_Fire_Alarm_Control_panel__1.jpg | JPG image | |
| B258_Fire_Alarm_Control_panel__6.jpg | JPG image | |
| B258_Fire_Alarm_Control_panel__3.jpg | JPG image |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE: 1/4"=1'-0"
WET PIPE SPRINKLER SYSTEMS
PARTIAL FLOOR PLAN-
FP104
ADMIN. AREA
(LH)
BLADDER MAINTENANCE ROOM
(OH-3)
STORAGE
ROOM
FROM EAST
SUPPORT AREA
AFFF ROOM
(OH-2)
MECHANICAL ROOM
(OH-2)
N
N
400 HZ
POWER ROOM
(OH-2)
ELECTRICAL ROOM
(OH-2)
COMM. ROOM
(OH-2)
INSPECTOR'S
TEST
CONTINUOUS LENGTH OF PIPE THIS SECTION
USE OF FITTINGS PROHIBITED
TO NORTH
ADMIN/SUPPORT
AREA
12'8'4'2'0 1'
SCALE: 1/4" = 1'-0"
4" WET PIPE
SPRINKLER
RISER
4"
LENGTH VARIES
12"
1" x 0'-2" NIPPLE
NOT TO SCALE
ARMOVER SPRINKLER FEED
BRANCH LINE
L L
CEILING TILE
C OF HEAD AND C OF
GYPSUM CEILING
HEAD (SEE DETAIL)
RECESSED SPRINKLER
1" DROP NIPPLE
CEILING
RECESSED CEILING ESCUTCHEON
FUSIBLE ELEMENT
HEAD
PENDENT SPRINKLER
RECESSED SPRINKLER
NOT TO SCALE
FP104
FP104
O 'K O N
C O M P A N Y
R
EM
A R K S
D A
TE
N O
REVISIONS
PROJECT NO.: 9141
DATE:
CHECKED:
DRAWN:
SHEET NUMBER:
En gi ne er s/
D es ig ne rs
P ea ch tr ee S tr ee t N .E
Su it e
A tl an ta G eo rg ia
(4
5-
FU
EL
S
YS
TE
M S
M A
IN
TE
N A N C E D O C K
1s t A
IR
R
EF
U
EL
IN
G W
IN
G
P
IT
TS
B U R G H I N
TE
R N A
TI
O N A L A
IR
P O R T, P
A
P
EN
N
SY
LV
A N
IA
A
IR
N
A
TI
O N A L G U A R D
P R O
JE
C T
JL
SQ
12/5/94
FINAL SUBMITTAL
1" 14'-0"
1" 1 1/4" 14'-0"
1 1/4" 12'-6"
1" 14'-0"
1 1/4" 14'-0"
1 1/4" 12'-6"
1" 14'-0"
1 1/4" 14'-0"
1 1/4" 12'-6"
1 1/2" 6'-0"
1 1/2" 6'-0"
1 1/2" 6'-0"
1 1/2" 6'-0"
1 1/4" 8'-6"
1 1 /4
9'- 0"
1'- 0"
1"
11' -0
1 1/4"
1" 6'-
6"
1 1 /4
3'- 0"
1 1/4" 2'-0" 4'-9"
1/
2" 8' 0"
3' 6"
1/
2" 5' 0"2"
1'-0"
1"
4'- 0"
1'-9"
2'-6" 4"3'-3" 1'-3"
4"
RN
1/
2"x '-9
RN
"x 5'-
6"
9"
6"
4"66'-0"
3"6'-6"
2 1/2" 10'-9"
1 1/4"2'-0" 1 1/4"
7'-6"
1"6'-3" 3"
3'- 9"
3'- 6"
5'- 9"
1 1/4" 4'-0"
1" 11'-0"
1" 11'-0"
11'-0" 2 1/2" 2 1/2"
5'-6"1'-3"
1'-9"
FLUSHING CONN.
1 1/4" MIN.
1/
2" 0"
8' 0"
1/
2"
INSPECTOR'S
TEST
1 1/2" 8'-6"
1 1/4"
11'-0"
1 1/4"
12'-0"
1"
11'-0"
1 1/4" 7'-0"
1 1/4" 12'-0"
1" 11'-0"
SEE
DETAIL 2
2'
2" 6'-9"
2" 6'-0" 3'-0"
2" 5' 0"
2' 0"
1 1/4" 5'-6"
1"
7'-0"
1 1/4" 5'-3"
2' 0"
2' 6"
1"
1 1/4" 6'-3"
1" 10'-0"
1 1/4" 5'-0"
1 1/4" MIN.
FLUSHING CONN.
Model